York BQ 036 Heat Pump User Manual

036-21508-005-A-0305 ® DESCRIPTION YORK Sunline 2000™ heat pumps are convertible single package units with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS All units include: • Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards 3, 4 & 5 NOMINAL TONS • Permanently lubricated motors 10.0 SEER • Bottom or side air discharge configuration capability (field convertible) • Manufactured under the quality standards of ISO9001 • SimplicityTM Control Board • Copper tube/aluminum fin coils • Easy access to all components • Rigging holes in base rails for lifting • Fork lift slots on three sides • Single point power connection • Complete factory package - tested, charged and wired • CSA agency listing on all units BQ 036, 048 & 060 WARRANTY • Factory Limited Parts Warranty • One-year parts warranty • A Five-year parts warranty on the compressor and electric heat elements. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21508-005-A-0305 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 BELT DRIVE) - SIDE DUCT APPLICATION . . . 22 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . . . 3 10 SUPPLY AIR BLOWER PERFORMANCE (3 - 5 TON DIRECT DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . . . . . . . . . . . . . . 23 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . 12 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . 13 11 BELT DRIVE BLOWER MOTOR AND DRIVE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 40 12 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . 24 13 ELECTRIC HEATER CFM LIMITATIONS . . . . . 24 LIST OF FIGURES Fig. # Pg. # 1 UNIT CUTAWAY . . . . . . . . . . . . . . . . . . . . . . . . 12 2 TYPICAL FIELD POWER & CONTROL WIRING 34 3 UNIT DIMENSIONS (3 - 5 TON HEAT PUMP) FRONT VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4 UNIT WITH ECONOMIZER RAINHOOD . . . . . . 35 5 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD . . . . . . . . . . . . . . . . . . . . 36 6 UNIT DIMENSIONS (REAR VIEW) . . . . . . . . . . 36 7 DISCONNECT/BLOWER ACCESS LOCATION 37 8 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . 38 9 FOUR AND SIX POINT LOADING . . . . . . . . . . . 39 14 ELECTRICAL DATA - BQ036 & 048 DIRECT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 15 ELECTRICAL DATA - BQ060 DIRECT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET 26 16 ELECTRICAL DATA - BQ036 & 048 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 17 ELECTRICAL DATA - BQ060 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 18 ELECTRICAL DATA - BQ036 & 048 DIRECT DRIVE WITH POWR’D CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 10 ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . 40 19 ELECTRICAL DATA - BQ060 DIRECT DRIVE WITH POWR’D CONVENIENCE OUTLET . . . . . . . . . 30 LIST OF TABLES Pg. # 20 ELECTRICAL DATA - BQ036 & 048 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET . . . . 31 1 SOUND POWER RATING . . . . . . . . . . . . . . . . . 15 21 ELECTRICAL DATA - BQ060 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET . . . . . . . . . 32 2 CAPACITY RATINGS . . . . . . . . . . . . . . . . . . . . 15 22 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . 33 3 BQ036 COOLING CAPACITIES (3 TON) . . . . . 16 23 ELECTRIC HEAT CORRECTION FACTORS . . 33 4 BQ048 COOLING CAPACITIES (4 TON) . . . . . 17 24 VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . 33 5 BQ060 COOLING CAPACITIES (5 TON) . . . . . 18 25 UTILITIES ENTRY . . . . . . . . . . . . . . . . . . . . . . . 37 6 BQ HEATING CAPACITIES . . . . . . . . . . . . . . . . 19 26 MINIMUM CLEARANCES . . . . . . . . . . . . . . . . . 37 7 SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION . . . 20 27 BQ 4 POINT LOADS WEIGHT DISTRIBUTION 39 Tbl. # 8 SUPPLY AIR BLOWER PERFORMANCE (4 TON BELT DRIVE) - SIDE DUCT APPLICATION . . . 21 9 SUPPLY AIR BLOWER PERFORMANCE (5 TON 2 28 BQ 6 POINT LOADS WEIGHT DISTRIBUTION 39 29 CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . 39 30 OPERATING WEIGHTS (LBS.) . . . . . . . . . . . . . 39 Unitary Products Group 036-21508-005-A-0305 PRODUCT NOMENCLATURE 3-5 Ton Sunline Model Number Nomenclature B Q 048 C00 A 2 A AA 1 Product Generation 1 = First Generation 2 = Second Generation Product Catagory D = Air Cond., Single Package B = Heat Pump, Single Package Product Identifier M = R-22 Standard Efficiency (DCG/DCE) F = R-22 Medium Efficiency (DEG/DEE) H = R-22 High Efficiency (DHG/DHE) Q = R-22 Std. Effic Heat Pump (BCH) Nominal Cooling Capacity - MBH 036 = 3 Ton 048 = 4 Ton 060 = 5 Ton Installation Options Heat Type & Nominal Heat Capacity C00 = Cooling Only. Suitable for field installed electric heat E05 = 5 kW Electric Heat E07 = 7 kW Electric Heat E10 = 10 kW Electric Heat E15 = 15 kW Electric Heat E20 = 20 kW Electric Heat E30 = 30 kW Electric Heat Voltage 1 = 208/230-1-60 2 = 208/230-3-60 4 = 460-3-60 5 = 575-3-60 A = No Options Installed B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 J = Options 1, 2 & 3 K = Options 1, 2, & 4 L = Options 1,3 & 4 M = Options 1, 2, 3, & 4 N = Options 2 & 3 P = Options 2 & 4 Q = Options 2, 3, & 4 R = Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, & 5 V = Options 1, 4, & 5 W = Options 1, 3, 4, & 5 X = Options 3 & 5 Y = Options 4 & 5 Z = Options 3, 4, & 5 Additional Options (See Next Page) Options 1 = Disconnect 2 = Non-Pwr'd Conv Oultet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet Airflow A= Direct Drive B = Direct Drive/Single Input Econo D = Direct Drive/Motorized Damper L = Direct Drive/BAS Ready Econ (No BAS Controller)/2" Pleated Filters/Extra xfrmr & circuit bkr. N = Belt Drive P = Belt Drive/Single Input Econo R = Belt Drive/Motorized Damper Y = Belt Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters Unitary Products Group 3 036-21508-005-A-0305 PRODUCT NOMENCLATURE - Continued 3-6T Sunline Model Number Nomenclature Standard Cabinet AA AB AC AD AE AF AG AH AJ AK AL AM AN AS CA CB CC CD CE CF CG CH CJ CK CL CM CN CP CQ CR CS CT CU CV CW CX JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ 4 None Phase Monitor Coil Guard Dirty Filter Switch Phase Monitor & Coil Guard Phase Monitor & Dirty Filter Switch Coil Guard & Dirty Filter Switch Phase Monitor, Coil Guard, & Dirty Filter Switch SS Drain Pan SS Drain Pan & Phase Monitor SS Drain Pan & Coil Guard SS Drain Pan & Dirty Filter Switch SS Drain Pan, Phase Monitor, Coil Guard & Dirty Filter Switch Bottom Drain Connection CPC Controller with Dirty Filter Switch & Air Proving Switch CPC Controller, DFS, APS & Phase Monitor CPC Controller, DFS, APS & Coil Guard CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Cond. Coil CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. Coil CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch Johnson UNT Controller, DFS, APS & Phase Monitor Johnson UNT Controller, DFS, APS & Coil Guard Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Unitary Products Group 036-21508-005-A-0305 Standard Cabinet JR JS JT JU JV JW JX HA HB HC HD HE HF HG HH HJ HK HL HM HN HP HQ HR HS HT HU HV HW HX NA NB NC ND NE NF NG NH NJ NK NL NM NN NP NQ NR NS NT NU NV NW NX TA TB TC Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch Honeywell Excel 10 Controller, DFS, APS & Phase Monitor Honeywell Excel 10 Controller, DFS, APS & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap Coil Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch Novar ETC-3 Controller, DFS, APS & Phase Monitor Novar ETC-3 Controller, DFS, APS & Coil Guard Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Technicoat Condenser Coil Technicoat Condenser Coil & Phase Monitor Technicoat Condenser Coil & Coil Guard Unitary Products Group 5 036-21508-005-A-0305 Standard Cabinet TD TE TF TG TH TJ TK TL TM TN TP TQ TR TS TT TU TV TW TX TY TZ T1 T3 T4 T6 T7 T9 LA LB LC LD LE LF LG LH LJ LK LL LM LN LP LQ LR LS LT LU LV LW LX WA WB WC WD WE 6 Technicoat Condenser Coil & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, & Coil Guard Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil Technicoat Evaporator Coil & Phase Monitor Technicoat Evaporator Coil & Coil Guard Technicoat Evaporator Coil & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, & Coil Guard Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils Technicoat Evaporator & Condenser Coils & Phase Monitor Technicoat Evaporator & Condenser Coils & Coil Guard Technicoat Evaporator & Condenser Coils & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Condenser & SS Drain Pan Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & SS Drain Pan Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils & SS Drain Pan Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Simplicity Intelli-Comfort Controller Simplicity Intelli-Comfort Controller, & Phase Monitor Simplicity Intelli-Comfort Controller, & Coil Guard Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller Intelli-Comfort w/Mod Link Controller, & Phase Monitor Intelli-Comfort w/Mod Link Controller, & Coil Guard Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil Unitary Products Group 036-21508-005-A-0305 Standard Cabinet WF WG WH WJ WK WL WM WN WP WQ WR WS WT WU WV WW WX Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Cabinet BA BB BC BD BE BF BG BH BJ BK BL BM BN BS DA DB DC DD DE DF DG DH DJ DK DL DM DN DP DQ DR DS DT DU DV DW Hinged Filter Door & Toolless Access Panels Phase Monitor, Hinged Filter Door & Toolless Access Panels Coil Guard, Hinged Filter Door & Toolless Access Panels Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor & Coil Guard, Hinged Filter Door & Toolless Access Panels Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Coil Guard & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Coil Guard, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor & Coil Guard, Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Bottom Drain Connection, Hinged Filter Door & Toolless Access Panels CPC Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Unitary Products Group 7 036-21508-005-A-0305 Hinged Filter Door & Toolless Access Cabinet DX EA EB EC ED EE EF EG EH EJ EK EL EM EN EP EQ ER ES ET EU EV EW EX GA GB GC GD GE GF GG GH GJ GK GL GM GN GP GQ GR GS GT GU GV GW GX PA PB 8 CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap Coil Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Unitary Products Group 036-21508-005-A-0305 Hinged Filter Door & Toolless Access Cabinet PC PD PE PF PG PH PJ PK PL PM PN PP PQ PR Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels PS Novar ETC-3 Controller, DFS, APS, SS Drain Pan PT Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard PU Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils PV Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil PW Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils PX Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils UA Technicoat Condenser Coil, Hinged Filter Door & Toolless Access Panels UB Technicoat Condenser Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UC Technicoat Condenser Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UD Technicoat Condenser Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UE Technicoat Condenser Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UJ Technicoat Evaporator Coil, Hinged Filter Door & Toolless Access Panels UK Technicoat Evaporator Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UL Technicoat Evaporator Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UM Technicoat Evaporator Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UN Technicoat Evaporator Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UP Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UQ Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UR Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels US Technicoat Evaporator & Condenser Coils, Hinged Filter Door & Toolless Access Panels UT Technicoat Evaporator & Condenser Coils & Phase Monitor, Hinged Filter Door & Toolless Access Panels UU Technicoat Evaporator & Condenser Coils & Coil Guard, Hinged Filter Door & Toolless Access Panels UV Technicoat Evaporator & Condenser Coils & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UW Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UX Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UY Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UZ Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U1 Technicoat Condenser & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U3 Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U4 Technicoat Evaporator & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U6 Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U7 Technicoat Evaporator & Condenser Coils & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U9 Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels QA Simplicity Intelli-Comfort Controller with Hinged Filter Door & Toolless Access Panels QB Simplicity Intelli-Comfort Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels QC Simplicity Intelli-Comfort Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels Unitary Products Group 9 036-21508-005-A-0305 Hinged Filter Door & Toolless Access Cabinet QD QE QF QG QH QJ QK QL QM QN QP QQ QR QS QT QU QV QW QX Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolles Simplicity Intelli-Comfort Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XA Intelli-Comfort w/Mod Link Controller, Hinged Filter Door & Toolless Access Panels XB Intelli-Comfort w/Mod Link Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XC Intelli-Comfort w/Mod Link Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels XD Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels XE Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels XF Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XG Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XH Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XJ Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels XK Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XL Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XM Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XN Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels XP Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan XQ Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels XR Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolles XS Intelli-Comfort w/Mod Link Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels XT Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels XU Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels XV Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels XW Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XX Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels 10 Unitary Products Group 036-21508-005-A-0305 FEATURES • All models are available with a wide variety of factorymounted options such as electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, smoke detectors, and coil guards to make them suitable for almost every application. Fan Delays - Fan on and fan off delays are fully programmable and are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. • Nuisance Trip Protection- To prevent nuisance trouble calls, the control board uses a “three strikes, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the compressor. • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. All units are self-contained and assembled on full perimeter base rails with forklift holes on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All models are available with these “factory mounted” outdoor air damper options: • Single enthalpy economizer • Motorized outdoor air damper Supply air blowers are equipped with either a direct drive or a belt drive that can be adjusted to meet the exact requirements of the job. All compressors are equipped with internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch to protect all system components. • Simplicity™ Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls. • • All units have long lasting powder paint cabinets with 750 hour salt spray test approval under ASTM-B117 procedures. All models are CSA listed. • Warranty - All models include a one-year limited parts warranty on the complete unit. Compressors and electric heater elements carry a five-year warranty • Electric Heat Operation - All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive temperature by thermal limit switches. Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0ºF outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti short cycle delay can be temporarily overridden with the push of a button. Unitary Products Group The power supply wiring can be routed into the control box through a threaded pipe connection (field supplied) in the base pan of the unit or through a knockout in the wiring panel on the side of the unit. • BAS Controls - York’s Sunline™ series units offer factory mounted BAS controls such as SImplicity™ INTELLI-Comfort™, Novar, Honeywell, Johnson, and CPC. 11 036-21508-005-A-0305 FIGURE 1 - UNIT CUTAWAY FACTORY-INSTALLED OPTIONS • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. • ELECTRIC HEATERS - Wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. • FILTER OPTIONS - Standard units are shipped with 1” throw-away filters installed. 2” pleated filters are offered as a factory installed option. • CONVENIENCE OUTLET - This 110 volt outlet can be “powered” by the unit with a stepdown transformer or the unit may be ordered with a “non-powered” convenience outlet that can be wired in the field. • DISCONNECT SWITCH - For heat pump units with electric heat, an HACR breaker sized to the unit is provided. For heat pump units without electric heat, a switch sized to the largest electric heat available for the particular unit is provided. Factory-installed option only. • BAS - Building Automation System Controls Simplicity™ INTELLI-Comfort™ CONTROL - The York® Simplicity™ INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside The rainhood is painted to match the basic unit and must be field-assembled before installing. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • 12 PHENOLIC COATED EVAPORATOR AND CONDENSER COILS - Special coating process that utilizes Technicoat 10-1TM processes. Coating is applied by total immersion of the complete coil for maximum protection. Unitary Products Group 036-21508-005-A-0305 Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the on-board connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • Simplicity™ INTELLI-Comfort™ with MOD LINK CONTROL - The York® Simplicity™ INTELLI-Comfort™ with Mod Link control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. • Novar® BAS CONTROL - The Novar® ETC-3 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • JOHNSON CONTROLS BAS CONTROL - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • • CPC BAS CONTROL - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • BOTTOM DRAIN CONNECTION - An optional bottom drain connection is available for inside the curb connections for applications in cold environments to reduce freezing drain lines. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. • DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • HINGED FILTER DOOR/“TOOLLESS” BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance. NOTE:Knobs are shipped inside the unit to prevent shipping damage. These must be field installed for tool-less operation. FIELD-INSTALLED ACCESSORIES • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. • HONEYWELL BAS CONTROL - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • SMOKE DETECTORS - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • ELECTRIC HEATERS wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. • STAINLESS STEEL DRAIN PAN - An optional rustproof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • ROOF CURBS - Eight and fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. Unitary Products Group 13 036-21508-005-A-0305 Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. • POWER EXHAUST - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. • ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. • BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work. • CO2 SENSOR - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • HAIL GUARD - Hail guard is available to protect the unit from hail damage. This is a sloped hood that fits above the coil. The power exhaust option can only be used on bottom duct configurations. • 14 BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the Unitary Products Group 036-21508-005-A-0305 TABLE 1: SOUND POWER RATING1 UNIT SIZE ESP SOUND POWER (db 10-12 Watts) BLOWER Octave Band Centerline Frequency (Hz) CFM IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 SWL dB(A) dB(A) @ 10Ft.2 036 1,200 0.6 LOW 0.60 84 84 74 67 69 62 57 52 74 41 048 1,600 0.55 HIGH 0.80 85 85 75 68 70 63 58 53 75 42 060 2,000 0.45 HIGH 1.00 86 86 76 69 71 64 59 54 76 43 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes and expectation to any specification or guarantee requiring a dBA value or sound data in any other form than sound power level ratings. 2. At a distance of 10 feet from the blower. TABLE 2: CAPACITY RATINGS ARI RATINGS1 UNIT SIZE (MBH) 036 048 060 COOLING PERFORMANCE MBH 39 48 59 SEER 10.00 10.20 10.00 EER 9.20 9.25 9.20 SOUND HEATING CAPACITY RATING2 bels HSPF 8.6 8.6 8.4 7.3 6.7 7.0 47°F MBH 39.0 48.0 59.0 17°F COP 3.0 3.0 3.0 MBH 23.0 26.4 36.0 COP 2.1 2.0 2.1 NOTES: 1. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. 2. Rated in accordance with ARI Standard 270. SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hoursduring the same period. EER = Energy Efficiency Ratio-the cooling capacity in BTU’s per hour (BTUH) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt). COP = Coefficient of Performance - the total heating capacity provided by the refrigeration system, including circulating fan heat but excluding supplementary resistance (BTU’s per hour) divided by the total electric input (watts) x 3.412. HSPF = Heating Seasonal Performance Factor - the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. (Based on Region IV minimum design heating requirement). Unitary Products Group 15 036-21508-005-A-0305 TABLE 3: BQ036 COOLING CAPACITIES (3 TON) AIR ON EVAPORATOR COIL CFM 1750 1500 1400 1200 1050 900 WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 AIR ON EVAPORATOR COIL CFM 1750 1500 1400 1200 1050 900 WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 TEMPERATURE OF AIR ON CONDENSER COIL 85°F TOTAL CAP.1 MBH INPUT kW 51 46 42 42 49 45 41 41 48 44 40 40 47 41 38 37 45 41 36 36 45 39 35 35 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.4 3.3 3.3 3.3 3.4 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.2 3.2 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER 2 86 37 40 42 42 35 39 41 41 33 39 40 40 31 36 38 37 28 34 36 36 26 31 35 35 83 32 40 42 42 30 37 41 41 29 36 39 40 27 32 37 37 25 30 35 36 24 28 34 35 80 28 36 41 42 26 33 40 41 24 32 38 39 24 29 36 36 22 27 33 34 20 25 32 32 77 24 31 39 40 22 29 37 38 20 28 34 35 20 25 32 33 19 24 30 31 17 22 29 30 74 19 26 34 35 18 24 32 34 16 23 30 31 16 22 29 30 16 20 27 28 15 19 25 26 71 21 29 30 20 28 29 20 26 27 18 25 26 17 24 25 17 23 24 TOTAL 68 16 24 25 15 24 25 15 22 23 14 21 22 14 21 22 14 20 21 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER CAP.1 MBH INPUT kW 47 44 38 37 46 42 37 36 45 41 36 36 44 39 35 35 42 38 34 33 40 35 32 31 3.7 3.7 3.6 3.6 3.7 3.7 3.6 3.6 3.7 3.7 3.6 3.5 3.7 3.6 3.6 3.5 3.6 3.6 3.5 3.5 3.6 3.6 3.5 3.5 2 86 34 38 38 37 32 36 37 36 30 36 36 36 29 34 35 35 26 31 34 33 23 27 32 31 83 29 38 38 37 28 34 37 36 27 33 35 36 25 30 34 35 23 27 33 33 21 25 30 31 80 25 34 37 37 24 30 36 36 22 29 34 35 22 27 33 34 20 25 31 31 17 22 28 28 77 22 29 35 35 20 27 33 33 18 26 30 31 18 23 29 31 17 22 28 28 15 19 25 26 74 17 24 30 30 16 22 28 29 15 21 27 27 14 20 26 28 14 18 25 25 13 17 22 23 71 20 26 26 18 25 25 18 23 24 17 23 24 15 22 22 15 20 21 68 15 21 22 14 21 21 13 19 20 13 19 20 12 19 20 12 17 18 TEMPERATURE OF AIR ON CONDENSER COIL 105°F TOTAL 1 POWER CAP. MBH INPUT2 kW 44 40 35 35 43 38 34 34 42 37 33 32 41 35 32 31 40 34 30 30 38 32 29 29 4.0 4.0 3.9 3.9 4.0 4.0 3.9 3.9 4.0 4.0 3.9 3.8 4.0 3.9 3.9 3.8 3.9 3.9 3.8 3.8 3.9 3.9 3.8 3.8 115°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F 86 31 34 35 35 30 32 34 34 28 32 33 32 27 30 32 31 24 28 30 30 21 25 29 29 83 27 34 35 35 26 31 34 34 25 30 32 32 23 27 31 31 22 24 29 30 20 22 27 29 80 24 31 34 35 22 27 33 34 21 26 31 31 20 24 30 31 19 22 27 28 16 20 25 26 77 20 26 32 33 19 24 30 31 17 23 28 28 17 21 26 27 16 19 25 25 14 18 23 24 74 16 22 28 29 15 20 26 28 14 19 24 24 13 18 24 25 14 16 22 23 12 15 20 21 71 18 24 25 16 23 24 16 21 21 15 21 21 14 20 20 13 18 19 TOTAL 1 68 13 20 20 12 19 20 12 18 18 11 17 18 11 17 18 11 16 17 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER CAP. MBH INPUT2 kW 42 36 34 33 41 35 33 32 39 34 32 32 37 32 30 29 35 31 29 28 34 29 27 26 4.2 4.1 4.1 4.1 4.2 4.1 4.1 4.1 4.2 4.1 4.1 4.0 4.2 4.1 4.1 4.0 4.1 4.0 4.0 4.0 4.1 4.0 4.0 4.0 86 30 31 34 33 29 30 33 32 26 30 32 32 24 28 30 29 21 25 29 28 19 23 27 26 83 26 31 34 33 25 28 33 32 23 27 31 32 21 24 29 29 19 22 28 28 18 20 25 26 80 23 28 33 33 21 25 32 32 19 24 30 31 18 22 28 29 17 20 26 26 15 18 24 23 77 19 24 31 31 18 22 29 29 16 21 27 28 15 19 25 25 14 18 24 24 12 16 21 22 74 15 20 27 27 15 18 25 26 13 17 24 24 12 17 22 23 12 15 21 21 11 14 18 19 71 16 23 23 15 22 22 15 20 21 14 19 20 12 19 19 12 17 17 68 12 19 19 11 19 19 11 17 18 10 16 17 10 16 17 10 15 15 1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.35kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor. NOMINAL RATING 16 Unitary Products Group 036-21508-005-A-0305 TABLE 4: BQ048 COOLING CAPACITIES (4 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL TOTAL INPUT2 kW CFM WB °F CAP.1 MBH 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 56 53 49 49 55 52 48 48 53 51 47 47 52 49 46 45 50 47 44 44 4.1 4.0 4.0 3.9 4.0 4.0 3.9 3.9 4.0 4.0 3.9 3.9 4.0 3.9 3.8 3.8 3.9 3.9 3.8 3.7 2000 1800 1600 1400 1200 85°F 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER TOTAL 86 83 80 77 74 71 68 CAP.1 MBH 42 48 49 49 40 47 48 48 37 46 47 47 34 42 46 45 31 38 44 44 36 47 49 49 35 44 48 48 33 42 47 47 30 38 45 45 27 35 42 43 31 41 48 49 30 39 47 48 28 37 46 47 26 34 42 43 24 31 39 39 26 36 44 44 25 34 43 43 24 33 41 42 22 30 38 39 20 28 35 36 30 38 38 29 38 38 28 37 38 26 34 35 24 32 32 25 33 33 24 33 33 24 32 33 22 30 31 21 28 29 28 28 28 28 28 29 26 27 25 25 53 51 46 46 53 51 47 45 52 50 45 44 49 47 43 42 47 45 40 40 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER INPUT2 kW 4.5 4.4 4.3 4.3 4.4 4.4 4.3 4.2 4.4 4.3 4.2 4.1 4.3 4.2 4.1 4.1 4.2 4.2 4.1 4.0 86 83 80 77 74 71 68 40 46 46 46 38 44 47 45 36 44 45 44 33 42 43 42 29 37 40 40 35 45 46 46 33 44 47 45 32 43 45 44 29 38 42 42 25 34 39 39 29 41 45 46 28 39 45 45 27 38 44 44 25 34 40 40 22 30 36 36 24 35 41 41 23 34 40 40 23 34 40 40 21 30 36 36 18 27 32 32 30 35 35 29 36 35 29 36 36 26 32 32 23 29 29 24 30 30 24 31 30 25 31 31 22 28 28 20 25 25 24 24 26 25 27 27 24 24 22 22 TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 105°F TOTAL 1 CFM 2000 1800 1600 1400 1200 POWER CAP. MBH INPUT2 kW WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 51 46 43 43 50 45 42 42 49 44 41 41 47 42 39 39 44 40 38 37 4.9 4.7 4.6 4.6 4.8 4.7 4.6 4.5 4.8 4.6 4.5 4.4 4.7 4.5 4.4 4.4 4.6 4.5 4.4 4.3 115°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F TOTAL 1 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER 83 80 77 74 71 68 CAP. MBH INPUT2 kW 86 40 42 43 43 38 41 42 42 35 40 41 41 32 38 39 39 28 36 38 37 35 42 43 43 33 41 42 42 31 40 41 41 28 36 38 39 25 32 36 37 29 39 42 43 28 37 41 42 26 35 40 41 24 32 37 37 21 29 34 34 24 34 37 38 23 32 37 37 22 31 35 36 20 28 33 33 18 25 29 30 28 32 32 27 32 33 26 32 32 24 28 29 22 27 27 23 27 28 22 27 27 22 27 28 20 25 25 18 22 23 21 22 22 23 23 23 20 21 20 20 49 41 40 40 47 40 39 38 46 39 37 37 44 37 36 36 42 36 35 35 5.2 5.0 4.9 4.8 5.1 4.9 4.8 4.7 5.1 4.9 4.7 4.7 5.0 4.8 4.7 4.6 4.9 4.7 4.6 4.6 86 83 80 77 74 71 68 39 40 40 40 37 37 39 38 34 36 37 37 31 36 36 36 28 34 35 35 34 40 40 40 32 36 39 38 29 36 37 37 27 34 35 36 24 31 34 35 29 37 39 40 27 35 37 38 25 32 36 37 23 30 34 34 21 27 30 31 23 32 34 34 22 30 34 33 20 28 33 34 19 26 30 31 17 24 28 29 26 29 30 25 29 30 23 28 28 21 26 26 20 24 24 21 23 24 20 24 25 19 24 25 17 22 23 17 20 21 18 19 19 20 19 20 18 19 17 18 1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.35kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor. NOMINAL RATING Unitary Products Group 17 036-21508-005-A-0305 TABLE 5: BQ060 COOLING CAPACITIES (5 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL TOTAL INPUT2 kW CFM WB °F CAP.1 MBH 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 68 65 61 60 67 64 60 59 66 63 59 58 64 61 57 57 62 59 55 55 5.7 5.6 5.6 5.5 5.6 5.6 5.5 5.5 5.6 5.5 5.4 5.4 5.5 5.5 5.4 5.4 5.5 5.5 5.4 5.3 2500 2250 2000 1750 1500 85°F 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER TOTAL 86 83 80 77 74 71 68 CAP.1 MBH 51 58 61 60 48 57 60 59 45 56 59 58 42 52 57 57 38 48 55 55 44 56 61 60 42 54 60 59 40 51 59 58 37 47 56 57 34 43 52 54 38 50 59 59 36 48 57 58 34 45 55 57 32 42 51 53 30 39 47 49 31 43 53 53 30 42 51 52 29 40 50 52 27 37 46 48 25 35 43 45 37 46 47 36 45 46 35 44 46 33 41 44 31 39 41 30 39 40 30 39 40 29 39 41 28 37 39 26 35 37 33 33 33 34 33 36 32 34 30 32 67 64 59 58 66 63 57 57 65 61 56 56 62 59 54 54 60 57 52 52 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER INPUT2 kW 6.0 5.9 5.9 5.8 5.9 5.9 5.8 5.8 5.9 5.9 5.8 5.7 5.9 5.8 5.7 5.7 5.8 5.8 5.7 5.6 86 83 80 77 74 71 68 51 56 59 58 48 55 57 57 45 55 56 56 43 53 54 54 41 51 52 52 45 56 59 58 42 54 57 57 40 51 56 56 38 48 54 54 36 46 52 52 38 50 57 57 36 48 55 56 34 45 54 55 33 44 52 53 32 42 50 51 31 43 50 51 30 42 50 50 29 40 49 50 28 39 48 49 28 38 46 47 37 44 44 35 44 45 34 44 44 34 43 43 34 42 42 30 38 39 29 38 39 29 38 39 29 38 39 29 38 39 31 32 32 33 33 34 33 34 34 35 TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 105°F TOTAL 1 CFM 2500 2250 2000 1750 1500 POWER CAP. MBH INPUT2 kW WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 64 59 54 54 63 58 53 53 62 57 52 52 60 55 50 50 57 53 48 48 6.0 5.9 5.9 5.8 5.9 5.9 5.8 5.8 5.9 5.9 5.8 5.7 5.9 5.8 5.7 5.7 5.8 5.8 5.7 5.6 115°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F TOTAL 1 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER 83 80 77 74 71 68 CAP. MBH INPUT2 kW 86 51 51 54 54 48 51 53 53 45 51 52 52 41 48 50 50 38 47 48 48 44 51 54 54 42 51 53 53 39 49 52 52 37 46 50 50 34 43 48 48 38 49 51 52 36 46 52 52 34 44 51 51 32 41 48 48 30 38 45 45 31 42 46 46 30 40 46 46 28 38 46 46 27 36 43 43 25 34 41 41 36 40 41 34 40 41 33 40 40 31 39 39 30 37 38 29 33 33 28 34 35 27 35 36 26 34 34 26 32 32 26 26 28 27 30 31 29 30 28 28 60 54 49 49 60 54 49 49 59 53 48 47 56 51 46 45 53 48 44 43 6.9 6.6 6.5 6.5 6.8 6.6 6.5 6.4 6.8 6.5 6.4 6.4 6.7 6.5 6.4 6.3 6.6 6.4 6.3 6.2 86 83 80 77 74 71 68 50 54 49 49 47 47 49 49 44 45 48 47 40 43 46 45 36 41 44 43 43 53 49 49 41 47 49 49 38 45 48 47 35 43 46 45 31 39 44 43 37 47 48 49 35 45 47 48 33 42 46 46 30 38 43 43 27 35 39 40 30 41 42 43 29 39 42 43 27 36 42 43 25 33 38 38 23 30 35 36 34 35 35 32 36 37 31 36 36 29 33 33 26 30 30 27 28 28 26 30 31 26 31 32 24 28 28 22 26 26 22 23 24 25 25 25 24 25 22 23 1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.35kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor. NOMINAL RATING 18 Unitary Products Group 036-21508-005-A-0305 TABLE 6: BQ HEATING CAPACITIES Model Tonnage CFM RET. AIR °F 55 1750 70 80 55 1400 70 80 3 55 1200 70 80 55 1050 70 80 55 2000 70 80 55 4 1600 70 80 55 1200 70 80 55 2500 70 80 55 5 2000 70 80 55 1500 70 80 Unitary Products Group CAP & KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW OUTDOOR AIR TEMPERATURE, °F (72% RH) -10 13.1 2.9 11.9 3 10.9 3.1 12.4 2.7 11.4 2.9 10.4 3 11.8 2.7 10.8 2.9 9.9 2.9 11.2 2.6 10.2 2.8 9.3 2.8 12.3 3.4 11.8 3.5 10.9 3.6 12.1 3.3 11.6 3.4 10.7 3.5 10.9 3.1 10.5 3.2 9.6 3.3 18.2 5 17.5 5.2 16.1 5.4 18 4.7 17.3 4.9 15.9 5.1 16.2 4.5 15.6 4.7 14.4 4.9 0 16.4 3 15 3.1 13.6 3.2 15.5 2.9 14.1 3 13.1 3.1 14.8 2.8 13.5 3 12.4 3.1 14.1 2.7 12.8 2.9 11.7 3 17.3 3.5 16.6 3.6 15.3 3.7 17 3.4 16.3 3.5 15 3.6 15.3 3.2 14.7 3.3 13.5 3.4 24.7 5.1 23.7 5.3 21.8 5.6 24.4 4.8 23.5 5 21.6 5.3 22 4.6 21.2 4.8 19.5 5 10 23.5 3.2 21.5 3.4 19.6 3.4 22.5 3 20.3 3.2 18 3.2 21.3 3 19.4 3.1 17.8 3.2 20.3 2.9 18.5 3 16.7 3.1 22.5 3.6 21.6 3.8 19.9 4 22 3.5 21.2 3.6 19.5 3.8 19.9 3.3 19.1 3.4 17.6 3.5 31.1 5.2 29.9 5.4 27.5 5.7 30.8 4.9 29.6 5.1 27.2 5.4 27.8 4.7 26.7 4.9 24.6 5.1 20 29.1 3.3 26.7 3.4 24.3 3.5 27.7 3.1 25.2 3.3 23.2 3.4 26.5 3.1 24 3.3 22 3.4 25.2 3 22.8 3.2 20.7 3.3 28.2 3.6 27.1 3.8 24.9 4 27.7 3.6 26.6 3.7 24.5 3.9 24.9 3.4 24 3.5 22 3.6 38.4 5.3 37 5.5 34 5.8 38.1 5 36.6 5.2 33.7 5.5 34.3 4.8 33 5 30.4 5.2 30 30.2 3.5 27.7 3.6 25.2 3.8 28.7 3.3 26.1 3.5 24.2 3.6 27.5 3.3 24.9 3.4 22.9 3.5 26.1 3.3 23.6 3.3 21.5 3.4 36.3 3.8 34.9 4 32.1 4.1 34.5 3.6 33.2 3.8 30.5 4 31.7 3.5 30.5 3.6 28.1 3.8 45.6 5.3 43.9 5.6 40.4 5.9 45 5.3 43.3 5.5 39.8 5.8 41.4 5 39.8 5.2 36.6 5.5 40 41.7 3.7 38.2 3.8 34.8 3.9 39.6 3.5 36.1 3.7 33.3 3.8 37.8 3.4 34.4 3.6 31.5 3.7 35.9 3.3 32.7 3.5 29.8 3.6 44.5 4 42.8 4.2 39.4 4.4 42.3 3.8 40.7 4 37.4 4.2 38.9 3.7 37.4 3.8 34.4 4 55.4 5.6 53.3 5.9 49 6 54.7 5.5 52.6 5.8 48.4 6.1 50.2 5.3 48.3 5.5 44.5 5.8 50 47 3.8 43.1 3.9 39.3 4.1 44.7 3.6 40.7 3.8 37.6 3.9 42.7 3.5 38.8 3.7 35.6 3.8 40.6 3.5 36.9 3.6 33.6 3.7 53.8 4.6 51.7 4.8 47.6 5 51.2 4.4 49.2 4.6 45.3 4.8 47 4.2 45.2 4.4 41.6 4.6 64.7 5.9 62.2 6.2 57.2 6.5 63.9 5.8 61.4 6.1 56.5 6.4 58.7 5.5 56.4 5.8 51.9 6.1 60 48.2 3.9 44.1 4.1 40.2 4.2 45.8 3.7 41.6 3.9 38.5 4 43.7 3.6 39.7 3.8 36.5 3.9 41.6 3.5 37.8 3.7 34.4 3.8 61.6 5.2 59.2 5.4 54.5 5.7 58.6 5 56.3 5.2 51.8 5.4 53.8 4.8 51.7 5 47.6 5.2 75.6 6.5 72.7 6.8 66.9 7.2 74.7 6.4 71.8 6.7 66.1 7 68.6 6.1 66 6.4 60.7 6.7 19 036-21508-005-A-0305 TABLE 7: SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 3 1, 2 UNIT TONNAGE 3 1, 2 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 3 0.60 0.40 0.50 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 745 881 815 920 900 961 970 1001 1030 1600 - - - - 818 665 858 740 898 820 940 890 980 950 1500 - - - - - - 842 695 882 755 922 835 962 895 1400 - - - - - - 833 650 867 705 904 765 942 820 1300 - - - - - - - - 858 665 893 725 932 785 1200 - - - - - - - - 847 640 880 680 916 730 0.20 0.30 0.70 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 3 1.10 1.20 1.30 0.80 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 1103 1270 - - - - - - - - - - - - 1900 1085 1210 - - - - - - - - - - - - 1800 1064 1145 1102 1180 - - - - - - - - - - 1700 1040 1075 1081 1115 1121 1140 - - - - - - - - 1600 1020 1005 1060 1050 1100 1085 - - - - - - - - 1500 1003 945 1044 995 1086 1035 - - - - - - - - 1400 982 880 1024 920 1067 965 1107 1000 - - - - - - 1300 970 835 1010 870 1053 920 1099 960 - - - - - - 1200 953 780 992 815 1034 855 1080 905 - - - - - - 0.90 1.00 1.40 1.50 1. 230/460/575 Volts 2. For 208 Volts multiply values by 0.95. 3. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows. 20 Unitary Products Group 036-21508-005-A-0305 TABLE 8: SUPPLY AIR BLOWER PERFORMANCE (4 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 4 1, 2 UNIT TONNAGE 4 1, 2 AVAILABLE EXTERNAL STATIC PRESSURE-IWG3 0.60 0.40 0.50 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 745 881 815 920 900 961 970 1001 1030 1600 - - - - 818 665 858 740 898 820 940 890 980 950 1500 - - - - - - 842 695 882 755 922 835 962 895 1400 - - - - - - 833 650 867 705 904 765 942 820 1300 - - - - - - - - 858 665 893 725 932 785 1200 - - - - - - - - 847 640 880 680 916 730 0.20 0.30 0.70 AVAILABLE EXTERNAL STATIC PRESSURE-IWG3 1.10 1.20 1.30 0.80 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 1103 1270 - - - - - - - - - - - - 1900 1085 1210 - - - - - - - - - - - - 1800 1064 1145 1102 1180 - - - - - - - - - - 1700 1040 1075 1081 1115 1121 1140 - - - - - - - - 1600 1020 1005 1060 1050 1100 1085 - - - - - - - - 1500 1003 945 1044 995 1086 1035 - - - - - - - - 1400 982 880 1024 920 1067 965 1107 1000 - - - - - - 1300 970 835 1010 870 1053 920 1099 960 - - - - - - 1200 953 780 992 815 1034 855 1080 905 - - - - - - 0.90 1.00 1.40 1.50 1. 230/460/575 Volts 2. For 208 Volts multiply values by 0.95. 3. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows. Unitary Products Group 21 036-21508-005-A-0305 TABLE 9: SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 5 1, 2 UNIT TONNAGE 5 1, 2 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 3 0.60 0.40 0.50 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 2200 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 2100 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 2000 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 1900 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 1800 - - - - 855 815 903 860 950 905 988 940 1022 970 1700 - - - - - - 884 815 925 850 964 880 1001 910 1600 - - - - - - 864 770 908 805 948 835 987 870 1500 - - - - - - - - 882 740 926 780 965 830 0.20 0.30 0.70 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 3 1.10 1.20 1.30 0.80 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2500 - - - - - - - - - - - - - - 2400 1193 1665 - - - - - - - - - - - - 2300 1170 1580 1202 1620 - - - - - - - - - - 2200 1148 1480 1180 1530 - - - - - - - - - - 2100 1121 1385 1155 1425 1190 1475 - - - - - - - - 2000 1100 1285 1133 1340 1169 1385 1205 1445 - - - - - - 1900 1079 1180 1110 1240 1143 1280 1178 1330 1222 1375 - - - - 1800 1058 1060 1090 1135 1122 1190 1158 1240 1196 1295 - - - - 1700 1035 960 1071 1030 1103 1100 1134 1140 1164 1175 1197 1205 - - 1600 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 1198 1150 1500 1004 860 1038 880 1070 925 1101 980 1130 1045 1158 1075 1184 1110 0.90 1.00 1.40 1.50 1. 230/460/575 Volts 2. For 208 Volts multiply values by 0.95. 3. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows. 22 Unitary Products Group 036-21508-005-A-0305 TABLE 10: SUPPLY AIR BLOWER PERFORMANCE (3 - 5 TON DIRECT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 3 4 5 4 5 MOTOR SPEED 1 1 1 UNIT TONNAGE 3 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 0.20 1 1 0.40 0.50 0.60 WATTS CFM WATTS CFM WATTS CFM WATTS CFM HI - - - - - - 1720 825 1665 795 MED 1660 850 1630 820 1590 780 1550 750 1500 720 LOW 1470 750 1440 725 1410 700 1370 675 1330 650 HI - - - - 2000 1010 1950 975 1905 945 MED 1810 910 1780 880 1740 850 1700 825 1665 800 LOW 1635 810 1610 780 1580 760 1555 740 1540 730 HI - - - - 2500 1400 2420 1350 2340 1300 MED 2390 1350 2350 1300 2300 1255 2245 1210 2190 1165 LOW 2270 1320 2230 1270 2190 1220 2145 1170 2090 1110 MOTOR SPEED 1 0.30 CFM AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 0.80 0.90 0.70 WATTS 1.00 CFM WATTS CFM WATTS CFM WATTS CFM WATTS HI 1600 765 1540 735 1490 700 1380 670 MED 1450 690 1400 665 1360 650 1270 610 LOW 1290 625 1250 610 1220 600 1130 560 HI 1840 910 1770 825 1660 825 1530 775 MED 1620 775 1560 740 1480 700 1390 660 LOW 1510 715 1460 690 1400 660 1300 615 HI 2260 1250 2160 1190 2060 1135 1925 1065 MED 2130 1120 2065 1075 1990 1030 1900 970 LOW 2030 1070 1960 1020 1890 970 1810 920 1. Side Duct application (230/460/575 Volts) 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. TABLE 11: BELT DRIVE BLOWER MOTOR AND DRIVE DATA MOTOR1 ADJUSTABLE MOTOR PULLEY BELT (NOTCHED) FIXED BLOWER PULLEY MODEL SIZE BLOWER RANGE (RPM) HP FRAME DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION PITCH LENGTH (IN.) QTY. 3 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK61 5.9 5.7 1 A36 37.3 1 4 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK61 5.9 5.7 1 A36 37.3 1 5 TON 850/1220 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK56 5.4 5.2 1 A36 37.3 1 1. All motors have solid bases and are inherently protected. these motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. Unitary Products Group 23 036-21508-005-A-0305 TABLE 12: STATIC RESISTANCES RESISTANCE, IWG DESCRIPTION CFM 1000 1200 1400 1600 1800 2000 2200 2400 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 5-15KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 ECONOMIZER1, 2 ELECTRIC HEATERS1 BOTTOM DUCT CONNECTIONS1 2600 1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables. 2. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. TABLE 13: ELECTRIC HEATER CFM LIMITATIONS UNIT MODEL SIZE NOMINAL TONS 3 4 5 24 MINIMUM SUPPLY AIR CFM VOLTAGE HEATER SIZE NOMINAL KW 5 7 10 15 20 30 208/230-1-60 1100 1100 1200 1200 1300 - 208/230-3-60 1100 1100 1200 1200 1300 - 460-3-60 - 1100 1200 1200 1300 - 575-3-60 - - 1200 1200 1300 - 208/230-1-60 1300 1300 1300 1300 1300 - 208/230-3-60 1300 1300 1300 1300 1300 - 460-3-60 - 1300 1300 1300 1300 - 575-3-60 - - 1300 1300 1400 - 208/230-1-60 1600 1600 1600 1600 1600 1600 208/230-3-60 1600 1600 1600 1600 1600 1600 460-3-60 - 1600 1600 1600 1600 1600 575-3-60 - - 1600 1600 1600 1800 Unitary Products Group 036-21508-005-A-0305 TABLE 14: ELECTRICAL DATA - BQ036 & 048 DIRECT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 4.4 0.0 230-1-60 19.0 105 1.7 4.4 0.0 208-3-60 11.9 85 1.7 4.4 0.0 230-3-60 11.9 85 1.7 4.4 0.0 460-3-60 5.9 42 1.0 2.2 0.0 575-3-60 4.8 34 1 2.2 0.0 208-1-60 25.0 105 2.3 5.0 0.0 230-1-60 25.0 105 2.3 5.0 0.0 208-3-60 14.7 130 2.3 5.0 0.0 230-3-60 14.7 130 2.3 5.0 0.0 460-3-60 7.7 64 1.3 2.2 0.0 575-3-60 6.4 52 1.3 2.2 0.0 3 4 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510525 2 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 NONE 2CE04510525 2 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2CE04510746 2 2 2CE04511046 2CE04511546 2 2CE04512046 2 NONE 2CE04511058 2CE04511558 2CE04512058 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510525 2 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2CE04510525 2 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 NONE 2CE04510746 2 2 2CE04511046 2CE04511546 2 2 2CE04512046 NONE 2CE04511058 2CE04511558 2CE04512058 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 29.9 53.9 63.5 77.9 101.4 125.4 29.9 57.5 68.9 85.1 112.7 140.3 21.0 34.9 40.4 48.7 62.3 76.1 21.0 36.9 43.5 52.8 68.8 84.7 10.6 20.8 25.8 31.0 39.9 8.6 21.3 27.7 34.1 38.6 62.6 72.2 86.6 110.1 134.0 38.6 66.2 77.6 93.8 121.4 149.0 25.7 39.6 45.1 53.4 67.0 80.8 25.7 41.6 48.2 57.5 73.5 89.4 13.1 23.3 28.3 33.6 42.4 10.8 23.5 29.9 36.3 Max Fuse / BRKR1 Size Amps 45 60 70 80 110 150 45 70 80 90 125 150 30 40 45 50 70 80 30 45 50 60 70 90 15 25 30 35 40 15 25 30 35 60 80 90 100 125 150 60 80 90 100 125 150 40 50 50 60 70 90 40 50 50 60 80 90 15 25 30 35 45 15 25 35 40 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 25 036-21508-005-A-0305 TABLE 15: ELECTRICAL DATA - BQ060 DIRECT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 6.6 0.0 230-1-60 32.1 148 2.3 6.6 0.0 208-3-60 19.3 137 2.3 6.6 0.0 230-3-60 19.3 137 2.3 6.6 0.0 460-3-60 10.0 62 1.3 3.3 0.0 575-3-60 7.9 50 1.3 3.3 0.0 5 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510525 2 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510525 2 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 2 2CE04513046 2 NONE 2CE04511058 2CE04511558 2CE04512058 2CE04513058 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 6.8 10.1 13.6 19.5 28.8 0.0 10.6 15.9 21.2 30.4 0.0 19.2 26.9 38.5 57.2 76.4 106.7 0.0 22.1 31.3 44.2 66.3 88.3 123.3 0.0 11.1 15.5 22.2 33.0 44.1 61.6 0.0 12.7 18.0 25.5 38.2 51.0 71.2 0.0 8.2 12.1 16.4 23.5 34.6 0.0 10.2 15.3 20.4 29.3 49.0 73.1 82.7 97.1 120.5 144.6 182.4 49.0 76.6 88.1 104.2 131.8 159.4 203.2 33.0 46.9 52.5 60.8 74.3 88.2 110.1 33.0 49.0 55.6 64.9 80.8 96.8 122.0 17.1 27.3 32.3 37.5 46.4 60.4 13.6 26.3 32.7 39.1 50.1 Max Fuse / BRKR1 Size Amps 80 100 100 110 125 150 200 80 100 110 125 150 175 225 50 60 60 70 80 90 125 50 60 70 70 90 100 125 25 35 35 40 50 70 20 30 35 40 60 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. 26 Unitary Products Group 036-21508-005-A-0305 TABLE 16: ELECTRICAL DATA - BQ036 & 048 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Compressors Model Tonnage Voltage RLA Each LRA Each OD Fan ID Blower Motor Motor FLA FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 7.6 0.0 230-1-60 19.0 105 1.7 7.6 0.0 208-3-60 11.9 85 1.7 5.2 0.0 230-3-60 11.9 85 1.7 5.2 0.0 460-3-60 5.9 42 1.0 2.6 0.0 575-3-60 4.8 34 1 2 0.0 208-1-60 25.0 105 2.3 7.6 0.0 230-1-60 25.0 105 2.3 7.6 0.0 208-3-60 14.7 130 2.3 5.2 0.0 230-3-60 14.7 130 2.3 5.2 0.0 460-3-60 7.7 64 1.3 2.6 0.0 575-3-60 6.4 52 1.3 2 0.0 3 4 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps Max Fuse / BRKR1 Size Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 NONE 2CE04511058 2CE04511558 2CE04512058 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2 2CE04510525 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510746 2 2CE04511046 2 2CE04511546 2CE04512046 2 NONE 2CE04511058 2CE04511558 2CE04512058 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 33.0 57.1 66.7 81.1 104.6 128.6 33.0 60.7 72.1 88.3 115.9 143.5 21.8 35.7 41.2 49.5 63.1 76.9 21.8 37.7 44.3 53.6 69.6 85.5 11.0 21.2 26.2 31.4 40.3 8.4 21.1 27.5 33.9 41.2 65.2 74.8 89.2 112.7 136.7 38.8 66.4 77.8 94.0 121.6 149.2 25.9 39.8 45.3 53.6 67.2 81.0 25.9 41.8 48.4 57.7 73.7 89.6 13.5 23.7 28.7 34.0 42.8 11.4 23.8 30.2 36.5 50 70 70 90 110 150 50 70 80 90 125 150 30 40 45 50 70 80 30 45 50 60 70 90 15 25 30 35 45 15 25 30 35 60 80 90 100 125 150 60 80 90 100 125 150 40 50 50 60 70 90 40 50 50 60 80 90 20 25 30 35 45 15 25 35 40 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 27 036-21508-005-A-0305 TABLE 17: ELECTRICAL DATA - BQ060 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 7.6 0.0 230-1-60 32.1 148 2.3 7.6 0.0 208-3-60 19.3 137 2.3 5.2 0.0 230-3-60 19.3 137 2.3 5.2 0.0 460-3-60 10.0 62 1.3 2.6 0.0 575-3-60 7.9 50 1.3 2 0.0 5 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510525 2 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510525 2 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 2 2CE04513046 2 NONE 2CE04511058 2CE04511558 2CE04512058 2CE04513058 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 6.8 10.1 13.6 19.5 28.8 0.0 10.6 15.9 21.2 30.4 0.0 19.2 26.9 38.5 57.2 76.4 106.7 0.0 22.1 31.3 44.2 66.3 88.3 123.3 0.0 11.1 15.5 22.2 33.0 44.1 61.6 0.0 12.7 18.0 25.5 38.2 51.0 71.2 0.0 8.2 12.1 16.4 23.5 34.6 0.0 10.2 15.3 20.4 29.3 50.0 74.1 83.7 98.1 121.5 145.6 183.4 50.0 77.6 89.1 105.2 132.8 160.4 204.2 31.6 45.5 51.1 59.4 72.9 86.8 108.7 31.6 47.6 54.2 63.5 79.4 95.4 120.6 16.4 26.6 31.6 36.8 45.7 59.7 12.5 25.3 31.6 38.0 49.1 Max Fuse / BRKR1 Size Amps 80 100 100 110 125 150 200 80 100 110 125 150 175 225 50 60 60 70 80 90 110 50 60 60 70 80 100 125 25 30 35 40 50 60 20 30 35 40 50 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. 28 Unitary Products Group 036-21508-005-A-0305 TABLE 18: ELECTRICAL DATA - BQ036 & 048 DIRECT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 4.4 10.0 230-1-60 19.0 105 1.7 4.4 10.0 208-3-60 11.9 85 1.7 4.4 10.0 230-3-60 11.9 85 1.7 4.4 10.0 460-3-60 5.9 42 1.0 2.2 5.0 575-3-60 4.8 34 1 2.2 4.0 208-1-60 25.0 105 2.3 5.0 10.0 230-1-60 25.0 105 2.3 5.0 10.0 208-3-60 14.7 130 2.3 5.0 10.0 230-3-60 14.7 130 2.3 5.0 10.0 460-3-60 7.7 64 1.3 2.2 5.0 575-3-60 6.4 52 1.3 2.2 4.0 3 4 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 NONE 2CE04511058 2CE04511558 2CE04512058 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2 2CE04510525 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 NONE 2CE04511058 2CE04511558 2CE04512058 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 39.8 63.9 73.5 87.9 111.4 135.4 39.8 67.5 78.9 95.1 122.7 150.3 31.0 44.9 50.4 58.7 72.3 86.1 31.0 46.9 53.5 62.8 78.8 94.7 15.6 25.8 30.8 36.0 44.9 12.6 25.3 31.7 38.1 48.6 72.6 82.2 96.6 120.1 144.1 48.6 76.2 87.6 103.8 131.4 159.0 35.7 49.6 55.1 63.4 77.0 90.8 35.7 51.6 58.2 67.5 83.5 99.4 18.2 28.4 33.4 38.7 47.5 14.8 27.5 33.9 40.5 Max Fuse / BRKR1 Size Amps 50 70 80 90 125 150 50 80 90 100 125 175 40 50 60 60 80 90 40 50 60 70 80 100 20 30 35 40 45 15 30 35 40 70 90 100 110 125 150 70 90 100 110 150 175 50 60 60 70 80 100 50 60 60 70 90 100 25 30 35 40 50 20 30 35 45 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 29 036-21508-005-A-0305 TABLE 19: ELECTRICAL DATA - BQ060 DIRECT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 6.6 10.0 230-1-60 32.1 148 2.3 6.6 10.0 208-3-60 19.3 137 2.3 6.6 10.0 230-3-60 19.3 137 2.3 6.6 10.0 460-3-60 10.0 62 1.3 3.3 5.0 575-3-60 7.9 50 1.3 3.3 4.0 5 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510525 2 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510525 2 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 2 2CE04513046 2 NONE 2CE04511058 2CE04511558 2CE04512058 2CE04513058 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 6.8 10.1 13.6 19.5 28.8 0.0 10.6 15.9 21.2 30.4 0.0 19.2 26.9 38.5 57.2 76.4 106.7 0.0 22.1 31.3 44.2 66.3 88.3 123.3 0.0 11.1 15.5 22.2 33.0 44.1 61.6 0.0 12.7 18.0 25.5 38.2 51.0 71.2 0.0 8.2 12.1 16.4 23.5 34.6 0.0 10.2 15.3 20.4 29.3 59.0 83.1 92.7 107.1 130.5 154.6 192.4 59.0 86.6 98.1 114.2 141.8 169.4 213.2 43.0 56.9 62.5 70.8 84.3 98.2 120.1 43.0 59.0 65.6 74.9 90.8 106.8 132.0 22.1 32.3 37.3 42.5 51.4 65.4 17.6 30.3 36.7 43.1 54.1 Max Fuse / BRKR1 Size Amps 90 110 110 125 150 175 200 90 110 110 125 150 175 225 60 70 70 80 90 100 125 60 70 80 80 100 110 150 30 40 40 45 60 70 25 35 40 45 60 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. 30 Unitary Products Group 036-21508-005-A-0305 TABLE 20: ELECTRICAL DATA - BQ036 & 048 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 7.6 10.0 230-1-60 19.0 105 1.7 7.6 10.0 208-3-60 11.9 85 1.7 5.2 10.0 230-3-60 11.9 85 1.7 5.2 10.0 460-3-60 5.9 42 1.0 2.6 5.0 575-3-60 4.8 34 1 2 4.0 208-1-60 25.0 105 2.3 7.6 10.0 230-1-60 25.0 105 2.3 7.6 10.0 208-3-60 14.7 130 2.3 5.2 10.0 230-3-60 14.7 130 2.3 5.2 10.0 460-3-60 7.7 64 1.3 2.6 5.0 575-3-60 6.4 52 1.3 2 4.0 3 4 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 NONE 2CE04511058 2CE04511558 2CE04512058 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 NONE 2 2CE04510525 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510525 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 NONE 2 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 NONE 2CE04511058 2CE04511558 2CE04512058 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 4.0 5.6 8.0 11.9 15.9 0.0 5.3 7.5 10.6 15.9 21.2 0.0 6.8 10.1 13.6 19.5 0.0 10.6 15.9 21.2 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 0.0 19.2 26.9 38.5 57.2 76.4 0.0 22.1 31.3 44.2 66.3 88.3 0.0 11.1 15.5 22.2 33.0 44.1 0.0 12.7 18.0 25.5 38.2 51.0 0.0 8.2 12.1 16.4 23.5 0.0 10.2 15.3 20.4 43.0 67.1 76.7 91.1 114.6 138.6 43.0 70.7 82.1 98.3 125.9 153.5 31.8 45.7 51.2 59.5 73.1 86.9 31.8 47.7 54.3 63.6 79.6 95.5 16.0 26.2 31.2 36.4 45.3 12.4 25.1 31.5 37.9 51.2 75.2 84.8 99.2 122.7 146.7 51.2 78.8 90.2 106.4 134.0 161.6 35.9 49.8 55.3 63.6 77.2 91.0 35.9 51.8 58.4 67.7 83.7 99.6 18.6 28.8 33.8 39.1 47.9 15.0 27.8 34.2 40.5 Max Fuse / BRKR1 Size Amps 60 80 80 100 125 150 60 80 90 100 150 175 40 50 60 60 80 90 40 50 60 70 80 100 20 30 35 40 50 15 30 35 40 70 90 90 110 125 150 70 90 100 110 150 175 50 60 60 70 80 100 50 60 60 70 90 100 25 30 35 40 50 20 30 35 45 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 31 036-21508-005-A-0305 TABLE 21: ELECTRICAL DATA - BQ060 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 7.6 10.0 230-1-60 32.1 148 2.3 7.6 10.0 208-3-60 19.3 137 2.3 5.2 10.0 230-3-60 19.3 137 2.3 5.2 10.0 460-3-60 10.0 62 1.3 2.6 5.0 575-3-60 7.9 50 1.3 2 4.0 5 Electric Heater Model No. Heater kW Heater Amps Minimum Circuit Ampacity Amps NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 NONE 2CE04510525 2 2 2CE04510725 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510525 2 2CE04510725 2 2CE04511025 2CE04511525 2CE04512025 2CE04513025 NONE 2CE04510746 2 2CE04511046 2 2CE04511546 2 2CE04512046 2 2CE04513046 2 NONE 2CE04511058 2CE04511558 2CE04512058 2CE04513058 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 4.0 5.6 8.0 11.9 15.9 22.2 0.0 5.3 7.5 10.6 15.9 21.2 29.6 0.0 6.8 10.1 13.6 19.5 28.8 0.0 10.6 15.9 21.2 30.4 0.0 19.2 26.9 38.5 57.2 76.4 106.7 0.0 22.1 31.3 44.2 66.3 88.3 123.3 0.0 11.1 15.5 22.2 33.0 44.1 61.6 0.0 12.7 18.0 25.5 38.2 51.0 71.2 0.0 8.2 12.1 16.4 23.5 34.6 0.0 10.2 15.3 20.4 29.3 60.0 84.1 93.7 108.1 131.5 155.6 193.4 60.0 87.6 99.1 115.2 142.8 170.4 214.2 41.6 55.5 61.1 69.4 82.9 96.8 118.7 41.6 57.6 64.2 73.5 89.4 105.4 130.6 21.4 31.6 36.6 41.8 50.7 64.7 16.5 29.3 35.6 42.0 53.1 Max Fuse / BRKR1 Size Amps 90 110 110 125 150 175 200 90 110 110 125 150 175 225 60 70 70 80 90 100 125 60 70 70 80 90 110 150 30 35 40 45 60 70 20 30 40 45 60 1. HACR Type per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. 32 Unitary Products Group 036-21508-005-A-0305 TABLE 22: PHYSICAL DATA BQ MODELS Centrifugal Blower (Dia. x Wd. in.) EVAPORATOR BLOWER EVAPORATOR COIL CONDENSER FANS CONDENSER COILS COMPRESSOR (Qty. Per Unit) AIR FILTERS CHARGE 12 X 10 12 X 10 1/2 3/4 1 1 1/2 1 1/2 1 1/2 Rows Deep 4 3 3 Fins Per Inch 16 15 15 Face Area (Sq. Ft.) 4.3 5.1 5.1 Propeller Dia. (in.) 22 22 24 Fan Motor Hp 1/3 1/2 1/2 4500 Nom. CFM 4300 4200 Rows Deep 1 1 1 Fins Per Inch 20 20 20 Face Area (Sq. Ft.) 17.1 17.1 17.1 Reciprocating Type 1 1 1 Quantity Per Unit (15” X 20” X 1” or 2“) 2 2 2 Quantity Per Unit (14” X 25” X 1” or 2“) 1 1 1 Total Face Area (sq. ft.) 6.6 6.6 6.6 Refrigerant 22 (lbs./oz.) 7/12 9/2 8/4 NOMINAL VOLTAGE VOLTAGE 208 208 1.00 0.92 480 460 0.92 600 575 0.92 Unitary Products Group 060 12 X 10 Fan Motor HP (Belt Drive) kW CAP. MULTIPLIER 230 048 Fan Motor HP (Direct Drive) TABLE 23: ELECTRIC HEAT CORRECTION FACTORS 240 036 TABLE 24: VOLTAGE LIMITATIONS1 VOLTAGE POWER SUPPLY MIN. MAX. 208/230-3-60 187 253 460-3-60 414 506 575-3-60 518 506 1. Utilization Range “A” in accordance with ARI Standard 110. 33 036-21508-005-A-0305 TYPICAL POWER WIRING REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTECTION AND WIRING. TYPICAL CONTROL WIRING COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT 1 TERMINALS ADD JUMPER RH UNIT TERMINAL STRIP TB1 RC R Y Y1 24 VOLT TRANSFORMER Y2 W W1 W2 G G C 1 24 VOLT THERMOSTAT 2ET07701024. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 2TH0471024. COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTAT1 TERMINALS ADD JUMPER RC UNIT TERMINAL STRIP TB1 RH R Y1 Y1 2 Y2 W1 4 3 G B C LED 1 ADD JUMPER X NOT USED OCC 4 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 (INCLUDES SUBBASE). 2 SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER. 3 SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER. RC R Y Y1 W W1 G G 24 VOLT TRANSFORMER TO REMOTE SENSOR 2TH040702224 IF USED 1 UNIT TERMINAL STRIP TB1 C A2 T 4 ADD JUMPER A1 T 1 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET07701024 (INCLUDES SUBBASE). TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THERMOSTAT 2TH04700224. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS A1 AND A2 PROVIDE A RELAY OUT-PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET-BACK POSITION. FIGURE 2 - 34 W2 G COM RH Y2 W1 W2 LED 2 THERMOSTAT1 TERMINALS 24 VOLT TRANSFORMER TYPICAL FIELD POWER & CONTROL WIRING Unitary Products Group 036-21508-005-A-0305 FIGURE 3 - UNIT DIMENSIONS (3 - 5 TON HEAT PUMP) FRONT VIEW DETAIL “A” FIGURE 4 - UNIT WITH ECONOMIZER RAINHOOD Unitary Products Group 35 036-21508-005-A-0305 DETAIL “B” FIGURE 5 - UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD FIGURE 6 - UNIT DIMENSIONS (REAR VIEW) 36 Unitary Products Group 036-21508-005-A-0305 FILTER ACCESS BLOWER MOTOR ACCESS DOT PLUGS FIELD-SUPPLIED DISCONNECT SWITCH LOCATION MOUNTING BRACKET FOR DICONNECT SWITCH (Shipped attached to the blower housing inside the blower compartment) A,B WIRING ENTRY (See Detail “B”) CONTROL BOX ACCESS DISCONNECT SWITCH LOCATION AND MOTOR ACCESS PANEL FOR UNIT WITH “BELT-DRIVE” OPTION FIGURE 7 - DISCONNECT/BLOWER ACCESS LOCATION TABLE 25: UTILITIES ENTRY HOLE OPENING SIZE (DIA.) TABLE 26: MINIMUM CLEARANCES USED FOR Side A 7/8” KO1 Control Wiring2 B 2” KO1 Power Wiring C 1-5/8” KO Gas Piping (Front) D 1-1/2” KO Gas Piping (Bottom) Bottom Side Bottom 1. Opening in the bottom to the unit can be located by the side in the insulation. 2. Do not remove the 2” knockout ring. LOCATION CLEARANCE Front 24” (Cooling/Electric Heat) 32” (Gas Heat) Rear 12” (Less Economizer) 36” (With Economizer or Fixed Air/Motorized Damper) Left Side (Filter Access) 24” (Less Economizer) 36” (With Economizer) Right Side (Cond. Coil) 24” Below Unit1 0” Above Unit2 72” (For Condenser Air Discharge) 1. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. Unitary Products Group 37 036-21508-005-A-0305 FIGURE 8 - 38 TYPICAL APPLICATIONS Unitary Products Group 036-21508-005-A-0305 BACK OF UNIT A 447/8 BACK OF UNIT A 447/8 821/4 821/4 D B F X X B APPROXIMATE CENTER OF GRAVITY FIGURE 9 - CONDENSER COIL END OF UNIT C Y FRONT OF UNIT C E APPROXIMATE CENTER OF GRAVITY D Y FRONT OF UNIT CONDENSER COIL END OF UNIT FOUR AND SIX POINT LOADING TABLE 27: BQ 4 POINT LOADS WEIGHT DISTRIBUTION UNIT TOTAL A B C D BQ036 628 139 137 174 177 BQ048 668 148 146 185 189 BQ060 693 154 151 192 196 TABLE 28: BQ 6 POINT LOADS WEIGHT DISTRIBUTION TOTAL A B C D E F BQ036 UNIT 628 93 92 91 116 117 119 BQ048 668 99 98 97 123 125 126 BQ060 693 103 102 100 128 129 131 3 TON 4 TON 5 TON 628 668 693 TABLE 29: CENTER OF GRAVITY DIMENSION 3 - 5 TON X 40-¾” Y 19-¾” TABLE 30: OPERATING WEIGHTS (LBS.) MODEL SIZE BASIC UNIT BQ Economizer 50 Motorized Damper OPTIONS Electric Heater 26 5 - 7 kW 18 10 - 15 kW 23 20 - 30 kW ACCY. Unitary Products Group 28 Roof Curb 92 Barometric Relief / Fixed Air Damper 10 Belt-Drive Blower 5 39 036-21508-005-A-0305 FIGURE 10 - ROOF CURB DIMENSIONS GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. York's Sunline 2000TM units are convertible single package heat pumps. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Models are available with a wide variety of factory-mounted options and field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non-Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch.The unit control circuit 40 includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All units have long lasting powder paint cabinets with 750 hour salt spray test approval under ASTMB117 procedures. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5-year warranty. DESCRIPTION Units shall be factory-assembled, single packaged heat pumps designed for outdoor mounted installation. The units shall have minimum SEER ratings of 10.0. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 750 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insu- Unitary Products Group 036-21508-005-A-0305 lated with a minimum 1/2” thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1” or 2” filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air bypass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards. Condensate connection shall be a minimum of 3/4” I.D. female and be a ridged mount connection. b. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed-orifice expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting without losing charge. d. The refrigeration system shall provide at least 15°F of sub-cooling at design conditions. UNIT CONTROLS a. Unit shall be complete with self-contained low-voltage control circuit protected by a resetable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze-protection thermostat, evaporator coil. f. If any of the above safety devices trip, a LED (lightemitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. g. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. h. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. i. Unit control board shall have on-board diagnostics and fault code display. j. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0°F. k. Control board shall monitor each refrigerant safety switch independently. l. Control board shall retain last 5 fault codes in non volatile memory, which will not be lost in the event of a power loss. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be direct drive, multi-speed, or a factory installed belt drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. REFRIGERANT COMPONENTS Compressor: a. b. Shall be internally protected with internal high-pressure relief and over temperature protection. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator and Condenser coils shall be of the direct expansion, draw-thru, design. ELECTRIC HEATING SECTION Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. Unitary Products Group An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 30 KW, offering two stages of capacity - 16 KW and above on 208/230 volt heaters and 20 KW and above on 460 and 575 volt heaters. The heating section shall have a primary limit control(s) and auto- 41 036-21508-005-A-0305 matic reset to prevent the heating element system from operating at an excessive temperature. The heating section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required). • UNIT OPERATING CHARACTERISTICS a. Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES MOTORIZED OUTDOOR AIR DAMPERS - Outdoor air dampers are positioned by a 2-position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE • ROOF CURB - 14"and 8” high, full perimeter curb with wood nailer (shipped knocked-down). • BAROMETRIC RELIEF DAMPER - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit. • POWER EXHAUST OPTION - To work in conjunction with economizers. • Compressor 5 Years • Electric Heat Element 5 Years • ELECTRIC HEATERS • Other Parts 1 Year • ECONOMIZER/MOTORIZED DAMPER RAIN HOOD Contains all hood panels and the hardware for assembling. • MANUAL OUTDOOR AIR DAMPER • COIL GUARD KIT - Guard for cooling coil. • HAIL GUARD OPTIONAL OUTDOOR AIR (Shall be made available by either/or): • 42 ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER- Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. OTHER FACTORY INSTALLED OPTIONS • POWER EXHAUST OPTION - To work in conjunction with economizers. • TECHNICOAT PHENOLIC COATED CONDENSER AND EVAPORATOR COIL • ELECTRONIC SINGLE ENTHALPY ECONOMIZER • DIRTY FILTER SWITCH • PHASE MONITOR • COIL GUARD • POWERED GFI CONVENIENCE OUTLET • NON-POWERED GFI CONVENIENCE OUTLET Unitary Products Group 036-21508-005-A-0305 • BAS CONTROLS (SImplicity™ INTELLI-Comfort™, CPC, JOHNSON, HONEYWELL, NOVAR) • BAS READY ECONOMIZER (BELIMO ACTUATOR WITHOUT A CONTROLLER) • HINGED FILTER DOOR ACCESS AND TOOLESS ACCESS PANELS • • BOTTOM DRAIN CONNECTION • 2" PLEATED FILTERS • DISCONNECT SWITCH • SUPPLY AIR SMOKE DETECTOR • RETURN AIR SMOKE DETECTOR STAINLESS STEEL DRAIN PAN Unitary Products Group 43 Subject to change without notice. Printed in U.S.A. Copyright © 2005 by Unitary Products Group. All rights reserved. Unitary Products Group 5005 York Drive 036-21508-005-A-0305 Supersedes: 036-21508-004-A-0504 Norman OK 73069
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement