American Standard SpeedConnect Drain Troubleshooting Guide

Add to My manuals
3 Pages

SpeedConnect Drain is a drain assembly for sinks that features a locking mechanism to prevent the stopper from being removed. This feature is ideal for high-traffic areas or where vandalism is a concern. Additionally, the SpeedConnect Drain allows for easy removal of the stopper, making it simple to clean or maintain. The drain comes with a cable adjustment procedure that allows you to adjust the length of the cable to ensure that the stopper operates correctly.

advertisement

American Standard SpeedConnect Drain Troubleshooting Guide | Manualzz

SpeedConnect™ Drain

Troubleshooting Guide

If sink does not hold water even though Stopper is in the “down” position:

• Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

• Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

• Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.

CABLE ADJUSTMENT PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. Fig. B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. Fig. B, C.

Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.

Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the

Drain Body Connection (2) and hand-tighten. Fig. A.

Fig.

A. Fig.

B. Fig.

C.

CAM

1

RE-ATTACH

STOPPER

CAM CAP

DISCONNECT

2

STOPPER REMOVAL PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.

The Stopper can now be removed by lifting it out of the Drain. Fig. F.

Fig.

D. Fig.

E.

REMOVE

CAM

REMOVE

CAM CAP

DOWN

1

M 9 6 8 3 0 5 R E V. 1 . 1

5

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).

Locked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.

To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the

Sink and the American Standard logo is facing front. Rotate

Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.

LOGO

LOOP TOWARD

REAR OF SINK

DRAIN

Locked Mode

(Vandal Proof)

Fig.

G.

Unlocked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.

To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the

Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.

Fig.

H.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable .

LOGO

LOOP TOWARD

FRONT OF SINK

DRAIN

Fig.

Unlocked Mode

H.

Fig.

J.

INSTALL CAM

CAM

Fig.

K.

INSTALL

CAM CAP

M 9 6 8 3 0 5 R E V. 1 . 1

6

060327-YYY0A

HANDLE KIT

SEVA™

SINGLE CONTROL CENTERSET

LAVATORY FAUCET

MODEL NUMBER

1480.110

1480.115

030126-0070A

H A N D L E

S C R E W K I T

M962510-YYY0A

LIFT ROD

A907468 -YYY0A

ESCUTCHEON CAP

023527-0070A

CARTRIDGE SCREWS

923391-0070A

CAP RETAINER

M952425-YYY0A

DRAIN ASSEMBLY

023529-0070A

CARTRIDGE

M919660-0020A

6” TAILPIECE

(NOT INCLUDED

WITH FAUCET)

066070-YYY0A

AERATOR

M962544-YYY0A

STOPPER

ASSEMBLY

M952430-0070A

CABLE ASSEMBLY

M962457-007A

FLANGE

ASSEMBLY

M922872-0070A

CAM SEAT INSERT

M962430-0070A

CAM ASSEMBLY

M913207-0070A

TAILPIECE INSERT

A919661-0020A

TAILPIECE

M962458-0070A

DRAIN MOUNTING KIT

065800-0070A

ATTACHMENT NUT

024220-0070A

SUPPLY NUT

Replace the "YYY" with appropriate finish code

CHROME

SATIN NICKEL

002

295

M953450-YYY0A

COMPLETE

DRAIN ASSEMBLY

066118-0070A

PIVOT ROD KIT

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1-800-442-1902

Weekdays 8:00 a.m. to 6:00 p.m. EST

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

IN MEXICO 01-800-839-12-00

P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c .

© A S A m e r i c a , I n c . 2 0 0 8

7

066116-YYY0A

DRAIN STOPPER

066117-YYY0A

2" FLANGE KIT

M961130-YYY0A

LIFT ROD AND KNOB

072574-0070A

EXTENSION ROD

070847-0070A

CLIP

M961711-0070A

TAILPIECE INSERT

070532-0040A

TAILPIECE

POP-UP DRAIN ASSEMBLY

BEFORE 07/06

M 9 6 8 3 0 5 R E V. 1 . 1

advertisement

Key Features

  • Locking mechanism prevents stopper removal
  • Easy removal of stopper for cleaning/maintenance
  • Cable adjustment procedure for proper operation
  • Durable construction for long-lasting use

Related manuals

Frequently Answers and Questions

How do I adjust the cable on my SpeedConnect drain?
To adjust the cable, first disconnect the cable from the drain by threading the cable connector counter-clockwise. Then locate the ''Cam'' on the drain body. Use a small screwdriver to rotate the ''Cam'' clockwise until the stopper is in the ''Up'' position. Push down on the lift-knob to make sure it is fully down. Finally, re-attach the cable to the drain by threading the cable connector clockwise and hand-tighten. This procedure is described in detail in the ''Cable Adjustment Procedure'' section of the viewed document.
How do I remove the stopper from my SpeedConnect drain?
To remove the stopper from your SpeedConnect drain, follow the ''Stopper Removal Procedure'' outlined in the viewed document. First, disconnect the cable from the drain by threading the cable connector counter-clockwise. Locate the ''Cam'' and ''Cam Cap'' on the drain body. Use fingers or a small screwdriver to pry the ''Cam Cap'' out from the drain. Then, remove the ''Cam'' by pulling it straight out while gently wiggling it to loosen the rubber seal. Finally, you can lift the stopper out of the drain.
How do I install the stopper in 'Locked' mode on my SpeedConnect drain?
To install the stopper in 'Locked' mode, insert the stopper into the drain so that the plastic loop is facing toward the rear of the sink and the American Standard logo is facing front. Rotate the stopper slightly if necessary to make sure it slides all the way down. Re-install the ''Cam'' into the drain, rotating it if necessary to ensure it is fully inserted. Re-install the ''Cam Cap,'' making sure the guide teeth are facing outward. If the ''Cam Cap'' does not ''snap'' into place, then rotate the ''Cam'' to make sure it is fully inserted. Finally, re-attach the cable and follow the 'Cable Adjustment Procedure' to complete the installation. The stopper will be in 'Locked' mode and not removable.
How do I install the stopper in 'Unlocked' mode on my SpeedConnect drain?
To install the stopper in 'Unlocked' mode, insert the stopper into the drain so that the plastic loop is facing toward the front of the sink and the American Standard logo is facing rear. Rotate the stopper slightly if necessary to make sure it slides all the way down. Re-install the ''Cam'' into the drain, rotating it if necessary to ensure it is fully inserted. Re-install the ''Cam Cap,'' making sure the guide teeth are facing outward. If the ''Cam Cap'' does not ''snap'' into place, then rotate the ''Cam'' to make sure it is fully inserted. Finally, re-attach the cable and follow the 'Cable Adjustment Procedure' to complete the installation. The stopper will be in 'Unlocked' mode and removable.