Supermicro SUPERSERVER 6014H-i2 User`s manual

Supermicro SUPERSERVER 6014H-i2 User`s manual

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Supermicro SUPERSERVER 6014H-i2 User`s manual | Manualzz
SUPER
®
SUPERSERVER 6014H-i2
SUPERSERVER 6014H-i
SUPERSERVER 6014H-Xi
USER’S MANUAL
1.0a
The information in this User’s Manual has been carefully reviewed and is believed to be
accurate. The vendor assumes no responsibility for any inaccuracies that may be
contained in this document, makes no commitment to update or to keep current the
information in this manual, or to notify any person or organization of the updates. Please
Note: For the most up-to-date version of this manual, please see our
web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in
this manual at any time and without notice. This product, including software, if any, and
documentation may not, in whole or in part, be copied, photocopied, reproduced, translated
or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT,
SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM
THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR
SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED
OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING,
INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR
DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of
Santa Clara County in the State of California, USA. The State of California, County of
Santa Clara shall be the exclusive venue for the resolution of any such disputes.
Supermicro's total liability for all claims will not exceed the price paid for the hardware
product.
Unless you request and receive written permission from SUPER MICRO COMPUTER, you
may not copy any part of this document.
Information in this document is subject to change without notice. Other products and
companies referred to herein are trademarks or registered trademarks of their respective
companies or mark holders.
Copyright © 2005 by SUPER MICRO COMPUTER INC.
All rights reserved.
Printed in the United States of America
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6014H-i2/6014H-i/6014H-Xi. Installation and maintainance should be
performed by experienced technicians only.
The SuperServer 6014H-i2/6014H-i/6014H-Xi is a high-end, dual processor
server based on the SC812i-420 1U rackmount server chassis and the
X6DHR-iG2/X6DHR-iG/X6DHR-XiG serverboard, which supports single or
dual Xeon TM processors at a Front Side (system) Bus speed of 800 MHz.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with
the server system and describes the main features of the X6DHR-iG2/
X6DHR-iG/X6DHR-XiG serverboard and the SC812i-420 chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer
6014H-i2/6014H-i/6014H-Xi into a rack and check out the server configuration prior to powering up the system. If your server was ordered without
processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general
overview of safety precautions that should be followed when installing and
servicing the SuperServer 6014H-i2/6014H-i/6014H-Xi.
iii
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X6DHR-iG2/X6DHR-iG/
X6DHR-XiG serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing
processors or main memory and when reconfiguring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC812i-420 1U rackmount
server chassis. You should follow the procedures given in this chapter
when installing, removing or reconfiguring IDE or peripheral drives and
when replacing the system power supply unit and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed
information on running the CMOS Setup Utility.
Appendix A: BIOS POST Messages
Appendix B: BIOS POST Codes
Appendix C: Software Installation
Appendix D: System Specifications
iv
Preface
Notes
v
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1
Overview ......................................................................................................... 1-1
1-2
Serverboard Features ................................................................................... 1-2
1-3
Server Chassis Features .............................................................................. 1-4
1-4
Contacting Supermicro .................................................................................. 1-6
Chapter 2: Server Installation
2-1
Overview ......................................................................................................... 2-1
2-2
Unpacking the System ................................................................................... 2-1
2-3
Preparing for Setup ....................................................................................... 2-1
Choosing a Setup Location .................................................................... 2-2
Rack Precautions ..................................................................................... 2-2
Server Precautions .................................................................................. 2-2
Rack Mounting Considerations .............................................................. 2-3
2-4
Installing the System into a Rack ................................................................ 2-4
Identifying the Sections of the Rack Rails .......................................... 2-4
Installing the Inner Rails ......................................................................... 2-4
Installing the Outer Rails ........................................................................ 2-4
Installing the Server into the Rack ....................................................... 2-6
Installing the Server into a Telco Rack ............................................... 2-7
2-5
Checking the Serverboard Setup ................................................................ 2-8
2-6
Checking the Drive Bay Setup ................................................................... 2-10
Chapter 3: System Interface
3-1
Overview ......................................................................................................... 3-1
3-2
Control Panel Buttons .................................................................................... 3-1
Reset .......................................................................................................... 3-1
Power ........................................................................................................ 3-1
3-3
Control Panel LEDs ........................................................................................ 3-2
Overheat/Fan Fail .................................................................................... 3-2
NIC2 ............................................................................................................ 3-2
NIC1 ............................................................................................................ 3-2
HDD ............................................................................................................ 3-2
vi
Table of Contents
Power ........................................................................................................ 3-3
Chapter 4: System Safety
4-1
Electrical Safety Precautions ....................................................................... 4-1
4-2
General Safety Precautions ......................................................................... 4-2
4-3
ESD Precautions ............................................................................................. 4-3
4-4
Operating Precautions ................................................................................... 4-4
Chapter 5: Advanced Serverboard Setup
5-1
Handling the Serverboard ............................................................................. 5-1
5-2
Processor and Heatsink Installation ............................................................ 5-2
5-3
Connecting Cables ......................................................................................... 5-5
Connecting Data Cables ......................................................................... 5-5
Connecting Power Cables ...................................................................... 5-5
Connecting the Control Panel ................................................................ 5-6
5-4
I/O Ports ........................................................................................................... 5-7
5-5
Installing Memory ............................................................................................ 5-7
5-6
Adding PCI Cards ........................................................................................... 5-9
5-7
Serverboard Details ..................................................................................... 5-10
X6DHR-iG2 Layout ................................................................................. 5-10
X6DHR-iG2 Quick Reference ............................................................... 5-11
X6DHR-iG/X6DHR-XiG Layout .............................................................. 5-12
X6DHR-iG/X6DHR-XiG Quick Reference ............................................ 5-13
5-8
Connector Definitions .................................................................................. 5-14
ATX Power Connector .......................................................................... 5-14
Processor Power Connector ............................................................... 5-14
NMI Button ............................................................................................... 5-14
Power LED .............................................................................................. 5-14
HDD LED .................................................................................................. 5-15
NIC1/NIC2 LED ........................................................................................ 5-15
Overheat/Fan Fail LED .......................................................................... 5-15
Power Fail LED ...................................................................................... 5-15
Reset Button ........................................................................................... 5-16
Power Button ......................................................................................... 5-16
Chassis Intrusion ................................................................................... 5-16
Universal Serial Bus .............................................................................. 5-16
Fan Headers ........................................................................................... 5-17
Serial Ports ............................................................................................. 5-17
ATX PS/2 Keyboard & Mouse Ports ................................................... 5-17
Power LED/Speaker .............................................................................. 5-18
vii
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Wake-On-Ring ........................................................................................ 5-18
Wake-On-LAN ........................................................................................ 5-18
3rd Power Supply Fail Detect Header ............................................... 5-19
SMB Connector ...................................................................................... 5-19
Overheat LED (JOH1) ........................................................................... 5-19
GLAN 1/2 (Ethernet Ports) ................................................................... 5-19
5-9
Jumper Settings ............................................................................................ 5-20
Explanation of Jumpers ........................................................................ 5-20
CMOS Clear ............................................................................................. 5-20
3rd Power Supply Alarm Enable/Disable ........................................... 5-21
VGA Enable/Disable .............................................................................. 5-21
Watch Dog Enable/Disable ................................................................... 5-21
GLAN Enable/Disable ............................................................................. 5-22
Memory Speed Select ........................................................................... 5-22
5-10 Onboard Indicators ...................................................................................... 5-22
GLAN LEDs ............................................................................................. 5-22
5-11 Floppy and Hard Disk Drive Connections ................................................ 5-23
Floppy Connector ................................................................................... 5-23
IDE Connectors ...................................................................................... 5-24
Chapter 6: Advanced Chassis Setup
6-1
Static-Sensitive Devices ............................................................................... 6-1
6-2
Control Panel ................................................................................................... 6-2
6-3
System Fans ................................................................................................... 6-3
System Fan Failure .................................................................................. 6-3
Replacing System Cooling Fans ............................................................ 6-3
6-4
Drive Bay Installation/Removal ..................................................................... 6-4
Removing the Front Bezel ...................................................................... 6-4
Accessing the Drive Bays ..................................................................... 6-5
Removing the Top Chassis Cover ........................................................ 6-5
IDE Drive Installation ................................................................................ 6-6
CD-ROM and Floppy Drive Installation ................................................. 6-8
6-5
Power Supply ................................................................................................. 6-9
Power Supply Failure ............................................................................. 6-9
Removing/Replacing the Power Supply ............................................... 6-9
Chapter 7: BIOS
7-1
Introduction ...................................................................................................... 7-1
7-2
Running Setup ................................................................................................. 7-2
7-3
Main BIOS Setup ............................................................................................. 7-2
viii
Table of Contents
Main BIOS Setup Menu ........................................................................... 7-3
7-4
Advanced Setup ............................................................................................. 7-7
7-5
Security .......................................................................................................... 7-18
7-6
Boot ................................................................................................................ 7-20
7-7
Exit .................................................................................................................. 7-21
Appendices:
Appendix A: BIOS POST Messages .................................................................... A-1
Appendix B: BIOS POST Codes ........................................................................... B-1
Appendix C: Software Installation ....................................................................... C-1
Appendix D: System Specifications .................................................................... D-1
ix
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1
Overview
The Supermicro SuperServer 6014H-i2/6014H-i/6014H-Xi is a high-end, dual
processor 1U rackmount server that features some of the most advanced
technology currently available. The SuperServer 6014H-i2/6014H-i/6014HXi is comprised of two main subsystems: the SC812i-420 1U rackmount
chassis and the X6DHR-iG2/X6DHR-iG/X6DHR-XiG dual processor
serverboard. Please refer to our web site for information on operating
systems that have been certified for use with the SuperServer 6014H-i2/
6014H-i/6014H-Xi. (www.supermicro.com)
In addition to the serverboard and chassis, various hardware components
may have been included with your SuperServer 6014H-i2/6014H-i/6014H-Xi,
as listed below:
z
Two (2) 10-cm system blower fans (FAN-0071)
z
One (1) 3.5" slim floppy drive
z
One (1) slim CD-ROM drive
z
Three (3) IDE drive trays (CSE-PT17)
z
One (1) riser card for standard size PCI-X card (CSE-RR1U-X)
z
One (1) riser card for low-profile PCI-X card (CSE-RR1U-XLP)
z
Rackmount hardware with screws (CSE-PT34):
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails to a rack/telco rack
z
One (1) CD-ROM containing drivers and utilities
z
SuperServer 6014H-i2/6014H-i/6014H-Xi User's Manual
z
Optional: One (1) chassis front bezel (CSE-PTFB-812)
1-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
z
Optional (cont.):
Two (2) 1U passive CPU heatsinks (SNK-0009)
One (1) riser card for standard size PCI-E (CSE-RR1U-E)*
One (1) riser card for low-profile PCI-E (CSE-RR1U-ELP)*
*Does not apply to the 6014H-Xi.
1-2
Serverboard Features
At the heart of the SuperServer 6014H-i2/6014H-i/6014H-Xi lies the X6DHRiG2/X6DHR-iG/X6DHR-XiG, a dual Intel Xeon TM processor serverboard designed to provide maximum performance. Below are the main features of
the X6DHR-iG2/X6DHR-iG/X6DHR-XiG.
Processors
The X6DHR-iG2/X6DHR-iG/X6DHR-XiG supports single or dual Intel 604-pin
EM64T Xeon processors at an 800 MHz FSB speed. Please refer to the
support section of our web site for a complete listing of supported processors (http://www.supermicro.com/support/).
Memory
The X6DHR-iG2 has eight 240-pin DIMM slots that can support up to 16 GB
of low-profile, registered ECC DDR2-400 SDRAM. The serverboard has has
been designed to support 2 GB DIMM modules for each memory slot, but it has
only been validated with 1 GB memory modules.
The X6DHR-iG/X6DHR-XiG has eight 184-pin DIMM slots that can support up
to 16 GB of low-profile, registered ECC DDR333 SDRAM or 32GB of lowprofile, registered ECC DDR266 SDRAM. The serverboard has has been
designed to support 2 GB DIMM modules for each memory slot, but it has only
been validated with 1 GB memory modules.
ATI Graphics Controller
Your serverboard features an integrated ATI video controller based on the
Rage XL graphics chip. Rage XL fully supports sideband addressing and
AGP texturing. This onboard graphics package can provide a bandwidth of
up to 512 MB/sec over a 32-bit graphics memory bus.
1-2
Chapter 1: Introduction
Onboard Controllers/Ports
The X6DHR-iG2/X6DHR-iG/X6DHR-XiG includes one floppy drive controller
and two onboard IDE controllers, which support up to four IDE hard drives
or ATAPI devices. Backpanel I/O ports include one COM port, two USB
ports, PS/2 mouse and keyboard ports, a VGA (monitor) port and two Gb
LAN ports.
Other Features
Other onboard features are included to promote system health. These include various voltage monitors, two CPU temperature sensors, four fan
speed sensors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
Figure 1-1.
E7520 Chipset Block Diagram
Processor 1
Processor 2
PCI-X Slot
PCI-X
ZCR
PCI-X Slot
DDR 266 (8 DIMMs)
DDR 333-4DIMM Double-sided
DDR 333-6DIMM Single-sided
PCI-X100
SCSI 7902
PCI-E
x8
PXH
PCI-X133
PCI-E Slot
PCI-E Slot
DDR333/
266
DIMMs 58
Hub
PCI-Ex8
SATA 0,1
SATA
USB
PCI-33MHz
6300 ESB
Hance
Rapids PCI-66MHz
USB 0-3
KB/
Mouse
DIMMs 14
PCI-Ex8
IDE PRI/
UDMA/100
SEC
Flash
ROM
DDR333/
266
E7520
Lindenhurst
MCH
VGA
GLAN
82541
LPC Bus
xBus
FDD
LPC I/O
BMC
Con.
(IPMI)
SER 1,2
H/W
Monitor
FW H
LPC I/O
Parallel
Port
Note: this is a general chipset block diagram. Please refer to sections 1-2 and 13 in this chapter and Chapter 5 for details on each server system.
1-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
1-3
Server Chassis Features
The SC812i-420 is one of Supermicro's newest 1U chassis and features
three IDE hard drive bays, a slim CD-ROM drive, a slim 3.5" floppy drive and
a revolutionary cooling design that can keep today's most powerful processors running well below their temperature thresholds. The following is a
general outline of the main features of the SC812i-420 chassis.
System Power
When configured as a SuperServer 6014H-i2/6014H-i/6014H-Xi, the SC812i420 chassis includes a single 420W power supply.
PCI Expansion Slots
The 6014H-i2 has two x8 PCI-Express slots, one 133 MHz PCI-X slot and
one 100 MHz PCI-X slot. Included riser cards support the use of one standard PCI-X card of any speed and one low-profile PCI-X card (100 or 66
MHz only). Alternatively, optional riser cards (sold separately) may be
added to support the use of two x8 PCI-Express cards. See section 5-6 for
details on riser cards.
The 6014H-i has two Universal PCI-X 133 MHz/PCI-Express x8/x4 slots.
Included riser cards support the use of one standard PCI-X card and one
low-profile PCI-X card of any speed. Alternatively, optional riser cards
(sold separately) may be added to support the use of one x8 PCI-Express
and one x4 PCI-Express card. See section 5-6 for details on riser cards.
The 6014H-Xi has two 133 MHz PCI-X slots. Riser cards included with the
server support the use of two (one standard and one low-profile) PCI-X
cards of any speed. See section 5-6 for details on riser cards.
Control Panel
The SC812i-420 control panel provides important system monitoring and
control information. Indicators include a power on LED, two network activity LEDs, a hard drive activity LED and a system overheat/fan fail LED. The
main power button and a system reset button may be found here. A gigabit
Ethernet port and two UBS 2.0 ports are also present for easy front side
access.
1-4
Chapter 1: Introduction
I/O Backplane
The SC812i-420 is a 1U rackmount chassis. Its I/O backplane provides one
full-height full-length and one low-profile PCI expansion slots, one COM port
(the other is internal), one VGA port, two USB ports, PS/2 mouse and
keyboard ports and two Ethernet (LAN) ports.
Cooling System
The SC812i-420 chassis' revolutionary cooling design has been optimized to
provide sufficient cooling for dual Xeon configurations in a 1U space. The
SC812i-420 includes two heavy duty 10-cm blower fans located in the
middle of the chassis. The speed of these fans may be controlled by DC
via a BIOS setting (see below). If a fan breaks down, the ambient air
temperature inside the chassis will rise and activate the overheat/fan fail
LED.
A setting in BIOS (see p. 7-17) is used to control the speed of the fans.
The recommended setting is "3-pin (Server)".
1-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
1-4
Contacting Supermicro
Headquarters
Address:
Tel:
Fax:
Email:
Web Site:
SuperMicro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
+1 (408) 503-8000
+1 (408) 503-8008
[email protected] (General Information)
[email protected] (Technical Support)
www.supermicro.com
Europe
Address:
Tel:
Fax:
Email:
SuperMicro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
+31 (0) 73-6400390
+31 (0) 73-6416525
[email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Asia-Pacific
Address:
SuperMicro, Taiwan
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei, Taiwan, R.O.C.
Tel:
+886-(2) 8226-3990
Fax:
+886-(2) 8226-3991
Web Site:
www.supermicro.com.tw
Technical Support:
Email:
[email protected]
Tel:
886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer
6014H-i2/6014H-i/6014H-Xi up and running. Following these steps in the
order given should enable you to have the system operational within a
minimum amount of time. This quick setup assumes that your SuperServer
6014H-i2/6014H-i/6014H-Xi system has come to you with the processors
and memory preinstalled. If your system is not already fully integrated with
a serverboard, processors, system memory etc., please turn to the chapter
or section noted in each step for details on installing specific components.
2-2
Unpacking the System
You should inspect the box the SuperServer 6014H-i2/6014H-i/6014H-Xi
was shipped in and note if it was damaged in any way. If the server itself
shows damage you should file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer
6014H-i2/6014H-i/6014H-Xi. It should be situated in a clean, dust-free area
that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a
grounded power outlet. Be sure to read the Rack and Server Precautions in
the next section.
2-3
Preparing for Setup
The box the SuperServer 6014H-i2/6014H-i/6014H-Xi was shipped in should
include two sets of rail assemblies, two rail mounting brackets and the
mounting screws you will need to install the system into the rack. Follow
the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you
begin the installation procedure outlined in the sections that follow.
2-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open
the front door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack
to allow for sufficient airflow and ease in servicing.
- This product is for installation only in a Restricted Access location
(dedicated equipment rooms, service closets and the like).
!
Warnings and Precautions!
!
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component
from the rack.
- You should extend only one component at a time - extending two or
more simultaneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you
install the rails.
- Install the heaviest server components on the bottom of the rack
first, and then work up.
- Use a regulating uninterruptible power supply (UPS) to protect the
server from power surges, voltage spikes and to keep your system operating in case of a power failure.
- Allow the IDE drives and power supply units to cool before touching
them.
- Always keep the rack's front door and all panels and components on
the servers closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating
temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing
the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow
required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition
does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might
have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack
itself should be grounded. Particular attention should be given to power
supply connections other than the direct connections to the branch circuit
(i.e. the use of power strips, etc.).
2-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
2-4
Installing the System into a Rack
This section provides information on installing the SuperServer 6014H-i2/
6014H-i/6014H-Xi into a rack unit with the rack rails provided. If the server
has already been mounted into a rack, you can skip ahead to Sections 2-5
and 2-6. There are a variety of rack units on the market, which may mean
the assembly procedure will differ slightly.
You should also refer to the
installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer
6014H-i2/6014H-i/6014H-Xi. Each of these assemblies consists of two sections: an inner fixed chassis rail that secures to the chassis and an
outer fixed rack rail that secures directly to the rack itself.
Two pairs of
short brackets to be used on the front side of the outer rails are also
included.
Installing the Inner Rails
First, locate the right inner rail (the rail that will be used on the right side
when you face the front of the chassis). Align the four square holes on
the right inner rail against the hooks on the right side of the chassis.
Securely attach the rail to the chassis with two M4 flat head screws.
Repeat these steps to install the left inner rail to the left side of the chassis.
Installing the Outer Rails
Begin by measuring the distance from the front rail to the rear rail of the
rack. Attach a short bracket to the front side of the right outer rail and a
long bracket to the rear side of the right outer rail. Adjust both the short
and long brackets to the proper distance so that the rail can fit snugly into
the rack.
Secure the short bracket to the front side of the outer rail with
two M4 screws and the long bracket to the rear side of the outer rail with
three M4 screws.
Repeat these steps for the left outer rail.
2-4
Chapter 2: Server Installation
Figure 2-1. Installing the Rack Rails
(with optional front bezel shown)
Locking Tabs
Both chassis rails have a locking tab, which serves two functions.
The
first is to lock the server into place when installed and pushed fully into
the rack, which is its normal position. Secondly, these tabs also lock the
server in place when fully extended from the rack.
This prevents the
server from coming completely out of the rack when you pull it out for
servicing.
2-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack
unit.
The next step is to install the server into the rack.
Do this by
lining up the rear of the chassis rails with the front of the rack rails.
Slide the chassis rails into the rack rails, keeping the pressure even on
both sides (you may have to depress the locking tabs when inserting).
See Figure 2-2.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that
hold the front of the server to the rack.
Figure 2-2. Installing the Server into a Rack
(with optional front bezel shown)
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
If you are installing the SuperServer 6014H-i2/6014H-i/6014H-Xi into a Telco
type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the position
ing of the rack brackets to the rack. They should be spaced apart just
enough to accommodate the width of the telco rack.
Figure 2-3.
Installing the Server into a Telco Rack
(with optional front bezel shown)
2-7
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
2-5
Checking the Serverboard Setup
After you install the 6014H-i2/6014H-i/6014H-Xi in the rack, you will need to
open the unit to make sure the serverboard is properly installed and all the
connections have been made.
1. Accessing the inside of the System (see Figure 2-4):
First, release the retention screws that secure the unit to the rack.
Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click"). Next, depress the two buttons on the top
of the chassis to release the top cover. There is a large rectangular
recess in the middle front of the top cover to help you push the cover
away from you until it stops. You can then lift the top cover from the
chassis to gain full access to the inside of the server.
2. Check the CPUs (processors):
You should have one or two processors already installed into the
serverboard. Each processor needs its own heatsink. See Chapter 5
for instructions on processor and heatsink installation.
3. Verify the proper CPU clock ratio setting:
If the CPU speed is not automatically detected you will need to set the
correct speed with the BIOS Setup utility. See the CPU speed setting in
BIOS (Chapter 7) for setting the proper CPU speed. (Most processor
speeds are automatically detected so this step should be unnecessary.)
4. Check the system memory:
Your 6014H-i2/6014H-i/6014H-Xi server system may have come with
system memory already installed. Make sure all DIMMs are fully seated in
their slots. For details on adding system memory, refer to Chapter 5.
5. Installing add-on cards:
If desired, you can install add-on cards to the system. See Chapter 5 for
details on installing PCI add-on cards.
2-8
Chapter 2: Server Installation
Figure 2-4. Accessing the Inside of the System
(with optional front bezel shown)
6. Check all cable connections and airflow:
Make sure all power and data cables are properly connected and not
blocking the chassis airflow. See Chapter 5 for details on cable connections. Also, check the air seals for damage. The air seals are located
under the blower fan and beneath the frame cross section that separates the drive bay area from the serverboard area of the chassis.
2-9
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
2-6
Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the IDE hard
drives have been properly installed and all connections have been made.
1. Accessing the drive bays:
All drives are accessable from the front of the server. For servicing the
CD-ROM, floppy and IDE disk drives, you will need to remove the top
chassis cover.
2. CD-ROM and floppy disk drives:
A slim CD-ROM and a slim floppy drive should be preinstalled in your
server. Refer to Chapter 6 if you need to reinstall a CD-ROM and/or
floppy disk drive to the system.
3. Check the IDE disk drives:
Depending upon your system's configuration, your system may have one
or more drives already installed. If you need to install IDE drives, please
refer to Chapter 6.
4. Check the airflow:
Airflow is provided by two heavy duty 10-cm blower fans. The system
component layout was carefully designed to direct sufficient cooling airflow to the components that generate the most heat. Note that all power
and data cables have been routed in such a way that they do not block
the airflow generated by the fans.
5. Supplying power to the system:
The last thing you must do is to provide input power to the system. Plug
the power cord from the power supply unit into a high-quality power
strip that offers protection from electrical noise and power surges. It is
recommended that you use an uninterruptible power supply (UPS).
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1
Overview
There are several LEDs on the chassis control panel as to keep you constantly informed of the overall status of the system as well as the activity
and health of specific components. There are also two buttons on the
chassis control panel. This chapter explains the meanings of the control
panel LED indicators and the appropriate response you may need to take
when one turns on.
3-2
Control Panel Buttons
There are two push-buttons located on the front of the chassis. These are
(in order from left to right) a reset button and a power on/off button.
z
RESET: The reset switch reboots the system.
z
POWER: This is the main power switch, which is used to apply or
turn off the main system power. Turning off system power with this button
removes the main power but keeps standby power supplied to the system.
3-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
3-3
Control Panel LEDs
The control panel located on the front of the SC812i-420 chassis has five
LEDs. These LEDs provide you with critical information related to different
parts of the system. This section explains what each LED indicates when
illuminated and any corrective action you may need to take.
z
Overheat/Fan Fail: IWhen this LED flashes, it indicates a fan failure.
When on continuously it indicates an overheat condition, which may be
caused by cables obstructing the airflow in the system or the ambient room
temperature being too warm. Check the routing of the cables and make
sure all fans are present and operating normally. You should also check to
make sure that the chassis covers are installed. Finally, verify that the
heatsinks are installed properly (see Chapter 5). This LED will remain flashing or on as long as the indicated condition exists.
z
NIC2:
Indicates network activity on GLAN2 when flashing .
z
NIC1:
Indicates network activity on GLAN1 when flashing.
z
HDD: Indicates IDE channel activity. On the SuperServer 6014H-i2/
6014H-i/6014H-Xi this light indicates IDE and CD-ROM drive activity when
flashing.
3-2
Chapter 3: System Interface
z
Power: Indicates power is being supplied to the system's power
supply units. This LED should normally be illuminated when the system is
operating.
3-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Notes
3-4
Chapter 4: System Safety
Chapter 4
System Safety
4-1
Electrical Safety Precautions
!
Basic electrical safety precautions should be followed to protect yourself
from harm and the SuperServer 6014H-i2/6014H-i/6014H-Xi from damage:
z Be aware of the locations of the power on/off switch on the chassis
as well as the room's emergency power-off switch, disconnection
switch or electrical outlet. If an electrical accident occurs, you can
then quickly remove power from the system.
z Do not work alone when working with high voltage components.
z Power should always be disconnected from the system when removing
or installing main system components, such as the serverboard,
memory modules and the CD-ROM and floppy drives. When
disconnecting power, you should first power down the system with
the operating system and then unplug the power cords of all the
power supply units in the system.
z When working around exposed electrical circuits, another person who
is familiar with the power-off controls should be nearby to switch off
the power if necessary.
z
Use only one hand when working with powered-on electrical
equipment. This is to avoid making a complete circuit, which will
cause electrical shock. Use extreme caution when using metal tools,
which can easily damage any electrical components or circuit boards
they come into contact with.
z
Do not use mats designed to decrease electrostatic discharge as
protection from electrical shock. Instead, use rubber mats that have
been specifically designed as electrical insulators.
4-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
z The power supply power cord must include a grounding plug and must
be plugged into grounded electrical outlets.
z Serverboard Battery: CAUTION - There is a danger of explosion if the
onboard battery is installed upside down, which will reverse its
polarities. This battery must be replaced only with the same or an
equivalent type recommended by the manufacturer. Dispose of used
batteries according to the manufacturer's instructions. See Figure 41.
z CD-ROM Laser: CAUTION - this server may have come equipped with
a CD-ROM drive. To prevent direct exposure to the laser beam and
hazardous radiation exposure, do not open the enclosure or use the
unit in any unconventional way.
4-2
General Safety Precautions
!
Follow these rules to ensure general safety:
z
Keep the area around the SuperServer 6014H-i2/6014H-i/6014H-Xi
clean and free of clutter.
z The SuperServer 6014H-i2/6014H-i/6014H-Xi weighs approximately 38
lbs (17.3 kg) when fully loaded. When lifting the system, two people
at either end should lift slowly with their feet spread out to distribute
the weight. Always keep your back straight and lift with your legs.
z Place the chassis top cover and any system components that have been
removed away from the system or on a table so that they won't
accidentally be stepped on.
z
While working on the system, do not wear loose clothing such as
neckties and unbuttoned shirt sleeves, which can come into contact
with electrical circuits or be pulled into a cooling fan.
z
Remove any jewelry or metal objects from your body, which are
excellent metal conductors that can create short circuits and harm you
if they come into contact with printed circuit boards or areas where
power is present.
4-2
Chapter 4: System Safety
z After accessing the inside of the system, close the system back up and
secure it to the rack unit with the retention screws after ensuring that all
connections have been made.
4-3
ESD Precautions
!
Electrostatic discharge (ESD) is generated by two objects with different
electrical charges coming into contact with each other. An electrical
discharge is created to neutralize this difference, which can damage
electronic components and printed circuit boards. The following
measures are generally sufficient to neutralize this difference before
contact is made to protect your equipment from ESD:
z Use a grounded wrist strap designed to prevent static discharge.
z Keep all components and printed circuit boards (PCBs) in their
antistatic bags until ready for use.
z Touch a grounded metal object before removing any board from its
antistatic bag.
z Do not let components or PCBs come into contact with your clothing,
which may retain a charge even if you are wearing a wrist strap.
z Handle a board by its edges only; do not touch its components,
peripheral chips, memory modules or contacts.
z When handling chips or modules, avoid touching their pins.
z Put the serverboard and peripherals back into their antistatic bags
when not in use.
z For grounding purposes, make sure your computer chassis provides
excellent conductivity between the power supply, the case, the mounting
fasteners and the serverboard.
4-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
4-4
Operating Precautions
!
Care must be taken to assure that the chassis cover is in place when
the 6014H-i2/6014H-i/6014H-Xi is operating to ensure proper cooling. Out
of warranty damage to the 6014H-i2/6014H-i/6014H-Xi system can occur
if this practice is not strictly followed.
Figure 4-1. Installing the Onboard Battery
LITHIUM BATTERY
LITHIUM BATTERY
OR
BATTERY HOLDER
BATTERY HOLDER
4-4
Chapter 5: Advanced Serverboard Setup
Chapter 5
Advanced Serverboard Setup
This chapter covers the steps required to install processors and heatsinks
to the X6DHR-iG2/X6DHR-iG/X6DHR-XiG serverboard, connect the data and
power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included
in this chapter. Remember to close the chassis completely when you have
finished working on the serverboard to protect and cool the system.
5-1
Handling the Serverboard
Static electrical discharge can damage electronic components. To prevent
damage to printed circuit boards, it is important to handle them very carefully (see Chapter 4). Also note that the size and weight of the serverboard
can cause it to bend if handled improperly, which may result in damage. To
prevent the serverboard from bending, keep one hand under the center of
the board to support it when handling. The following measures are generally sufficient to protect your equipment from static discharge.
Precautions
• Use a grounded wrist strap designed to prevent static discharge.
• Touch a grounded metal object before removing any board from its antistatic bag.
• Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.
• When handling chips or modules, avoid touching their pins.
• Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.
Unpacking
The serverboard is shipped in antistatic packaging to avoid static damage.
When unpacking the board, make sure the person handling it is static protected.
5-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
5-2
Processor and Heatsink Installation
!
When handling the processor package, avoid placing direct
pressure on the label area of the fan. Also, do not place the
serverboard on a conductive surface, which can damage the BIOS
battery and prevent the system from booting up.
IMPORTANT: Always connect the power cord last and always remove it before
adding, removing or changing any hardware components. Make sure that you
install the processor into the CPU socket before you install the CPU heat sink.
CPU Installation
1. Lift the lever on the CPU socket:
Lift the lever completely as shown
on the picture on the right; otherwise, you will damage the CPU
socket when power is applied. Install CPU1 first.
Socket lever
2. Insert the CPU in the socket,
making sure that pin 1 of the CPU
aligns with pin 1 of the socket (both
corners are marked with a triangle).
When using only one CPU, install it
into CPU socket #1. (Socket #2 is
automatically disabled if only one
CPU is used.)
Pin 1
3. Press the lever down until you
hear a *click*, which means the
CPU is securely installed in the
CPU socket.
Socket lever in the
locking Position
5-2
Chapter 5: Advanced Serverboard Setup
Figure 5-1. 604-pin PGA Socket: Empty and with Processor Installed
!
Warning! Make sure you lift the lever completely when
installing the CPU. If the lever is only partly raised, damage
to the socket or CPU may result.
Empty socket
With processor installed
Lever
Triangle (pin 1)
Triangle locating pin 1
Heatsink Installation*
1. Do not apply any thermal compound to the heatsink or the CPU die; the
required amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the retention mechanism.
3. Screw in two diagonal screws (e.g. the #1 and the #2 screws) until just
snug (do not fully tighten the screws to avoid possible damage to the CPU).
Screw in the two remaining screws until snug (see Figure 5-2).
4. Finish the installation by fully tightening all four screws.
*The heatsink package (SNK-P0009) is an optional item sold separately.
*Fan speed is controlled by a setting in BIOS (see page 7-17).
5-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Figure 5-2. Installing the Heatsink
Removing the Heatsink/CPU
!
IMPORTANT: Removal of the heatsink or the CPU is not recommended. However, if you do need to remove the heatsink, please
follow the instructions below to prevent damaging the CPU or the
CPU socket.
1. Unscrew and remove the heatsink screws from the serverboard in the
sequence as show in the picture above.
2. Hold the heatsink and gently wiggle it back and forth to loosen it from the
CPU. (Do not use excessive force when loosening the heatsink!!)
3. Once the heatsink has been loosened from the CPU, remove the heatsink
from the CPU socket.
4. Clean the surface of the CPU and the heatsink to get rid of the old thermal
grease. Reapply the proper amount of thermal grease on the surface before you re-install a heatsink to the CPU.
5-4
Chapter 5: Advanced Serverboard Setup
5-3
Connecting Cables
Now that the processors are installed, the next step is to connect the
cables to the serverboard. These include the data (ribbon) cables for the
peripherals and control panel and the power cables.
Connecting Data Cables
The ribbon cables used to transfer data from the peripheral devices have
been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back.
If you need to disconnect any of these cables, you should take care to keep
them routed as they were originally after reconnecting them (make sure the
red wires connect to the pin 1 locations). If you are configuring the system, keep the airflow in mind when routing the cables. The following data
cables (with their serverboard connector locations noted) should be connected.
See the serverboard layout figure in this chapter for connector locations.
z IDE drive cable (J5)
z CD-ROM cable (J6)
z Control Panel cable (JF1, see next page)
z Floppy drive cable (J12)
z Front Side USB cable (JD2)
z Front Side COM port cable (COM2)
Connecting Power Cables
The X6DHR-iG2/X6DHR-iG/X6DHR-XiG has a 20-pin primary power supply
connector at J1B1 designated "ATX Power" for connection to the ATX
power supply. Connect the appropriate connector from the power supply
to the J1B1 connector to supply power to the serverboard. The 12V 8-pin
processor power connector at J1D1 and the 12V 4-pin power connector at
J38 must also both be connected to your power supply. See the Connector
Definitions section in this chapter for power connector pin definitions.
5-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See
Figure 5-3 for the pin locations of the various front control panel buttons
and LED indicators. Please note that even and odd numbered pins are on
opposite sides of each header.
All JF1 wires have been bundled into single ribbon cable to simplify their
connection. Make sure the red wire plugs into pin 1 as marked on the
board. The other end connects to the Control Panel printed circuit board,
located just behind the system status LEDs in the chassis.
See the Connector Definitions section in this chapter for details and pin
descriptions of JF1.
Figure 5-3. JF1 Header Pins
20
19
Ground
NMI
X
X
Power LED
Vcc
HDD LED
Vcc
NIC1 LED
Vcc
NIC2 LED
Vcc
OH/Fan Fail LED
Vcc
Power Fail LED
Vcc
Ground
Reset
Reset Button
Ground
Pwr
Power Button
2
5-6
1
Chapter 5: Advanced Serverboard Setup
5-4
I/O Ports
The I/O ports are color coded in conformance with the PC 99 specification.
See Figure 5-4 below for the colors and locations of the various I/O ports.
Figure 5-4. Rear Panel I/O Ports
5-5
Installing Memory
Note: Check the Supermicro web site for recommended memory modules:
http://www.supermicro.com/support/resources/
CAUTION
Exercise extreme care when installing or removing DIMM
modules to prevent any possible damage. Also note that the
memory is interleaved to improve performance (see step 1).
DIMM Installation (See Figures 5-5a and 5-5b)
1. Insert the desired number of DIMMs into the memory slots, starting with
Bank #1A. The memory scheme is interleaved so you must install two
modules at a time, beginning with DIMM #1A, then DIMM #1B, and so on.
2. Insert each DIMM module vertically into its slot. Pay attention to the
notch along the bottom of the module to prevent inserting the DIMM
module incorrectly.
3. Gently press down on the DIMM module until it snaps into place in the
slot. Repeat for all modules (see step 1 above).
5-7
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Memory Support
All three serverboards use an interleaved memory scheme, so memory modules must be installed two at a time (two DIMMs in the same bank). You
should not mix modules of different sizes and/or speeds.
The X6DHR-iG2 has eight 240-pin DIMM slots that can support up to 16 GB
of registered ECC DDR2-400 SDRAM. The serverboard has has been designed to support 2 GB DIMM modules for each memory slot, but it has only
been validated with 1 GB memory modules.
The X6DHR-iG/X6DHR-XiG has eight 184-pin DIMM slots that can support up
to 16 GB of low-profile, registered ECC DDR333 SDRAM or 32GB of lowprofile, registered ECC DDR266 SDRAM. The serverboard has has been
designed to support 2 GB DIMM modules for each memory slot, but it has only
been validated with 1 GB memory modules.
Note: if ECC registered DDR333 (PC2700) memory modules are used, configurations of four double-banked DIMMs or six single-banked DIMMs are
supported.
Memory Speed Jumpers
Depending on what type of memory you use, you may need to change the
J4F4 and J4F5 (Memory Speed Select) jumpers. See section 5-9 for details.
Figure 5-5a.
Side View of DIMM Installation into Slot
To Install: Insert module vertically and press down until it snaps into
place. Pay attention to the bottom notch.
To Remove: Use your thumbs to gently push each release tab outward
to free the DIMM from the slot.
5-8
Chapter 5: Advanced Serverboard Setup
Figure 5-5b.
5-6
Top View of DIMM Slot
Adding PCI Cards
1. PCI slots
6014H-i2: Included riser cards support the use of one standard PCI-X card
of any speed and one low-profile PCI-X card (100 or 66 MHz only). Alternatively, optional riser cards (sold separately) may be added to support the
use of two x8 PCI-Express cards (see below).
6014H-i: Included riser cards support the use of one standard PCI-X card
and one low-profile PCI-X card of any speed. Alternatively, optional riser
cards (sold separately) may be added to support the use of one x8 PCIExpress and one x4 PCI-Express card (see below).
6014H-Xi: Riser cards included with this server support the use of two
(one standard and one low-profile) PCI-X cards of any speed.
Riser Cards (Standard)
CSE-RR1U-X
CSE-RR1U-XLP
Slot
PCI-X (L)
SXB-E (R)
Add-on Card
PCI-X
PCI-X (low profile)
Riser Cards (Optional)
Slot
Add-on Card
CSE-RR1U-EL
Univ. PCI (L)
PCI-E
CSE-RR1U-ELP
Univ. PCI (R)
Low-profile PCI-E
Note: (L) refers to left and (R) refers to right-side slots when viewed from
chassis front.
2. PCI card installation
Before installing a PCI add-on card, make sure you install it into a slot that
supports the speed of the card (see step 1, above). Begin by lifting the
latch from the PCI shield that corresponds to the slot you wish to populate.
Insert the PCI card into the riser card, pushing down with your thumbs
evenly on both sides of the card. Follow this procedure when adding a
card to other slots.
5-9
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
5-7
Serverboard Details
Figure 5-6. SUPER
X6DHR-iG2 Motherboard Layout
(not drawn to scale)
J32
Keyboard
J38
DIMM 1B
Mouse
J1D1
J1B1
DIMM 1A
JP9
JP11
DIMM 2A
USB 0/1
CPU1
DIMM 2B
JP10
DIMM 3A
FAN1
DIMM 3B
COM1
DIMM 4A
JF1
DIMM 4B
X6DHR-iG2
FAN2
J4F4
J4F5
SUPER
®
E7520
CPU2
GLAN
Controller
J3
J4
FAN5
SXB-E x8
J6 J5
J12
SXB-E x8
PCI-X 133 MHz
ZCR
IDE #1
IPMI
IDE #2
Floppy
GLAN2
FAN4
PCI-X 100 MHz
GLAN1
VGA
S I/O
JP6
PXH
WOR
ICH5R
RAGE-XL
Battery
FAN3
BIOS
SPKR
JPL1
JPG1
JBT1
J11
JD2
WOL
COM2
WD JOH
JL1
JD1
*Note:
Jumpers not indicated are for manufacturer test purposes only - do not
change these settings!
5-10
Chapter 5: Advanced Serverboard Setup
X6DHR-iG2 Quick Reference
Jumper
Description
Default Setting
J4F4/J4F5
JP9
JP10
JP11
JBT1
JPG1
JPL1
JWD
Memory Speed Select
PWR Force On
3rd PWR Supply Alarm En/Disable
Alarm Reset
CMOS Clear
VGA Enable/Disable
GLAN Enable/Disable
Watch Dog
Closed (DDR333)
Open (Normal)
Open (Disabled)
Closed (Enabled)
See Section 5-9
Pins 1-2 (Enabled)
Pins 1-2 (Enabled)
Pins 1-2 (Reset)
Connector
Description
COM1/COM2
DIMM#1A-DIMM#4B
FAN#1-5
GLAN1/2
J3/J4
J5/J6
J9
J11
J12
J32
J38
J1B1
J1D1
JD1
JD2
JF1
JL1
JOH1
JP11
JWOL
JWOR
USB0/1
VGA
COM1/COM2 Serial Port Connector/Header
Memory (SDRAM) Slots
Onboard CPU Fan/Chassis Fan Headers
Gigabit Ethernet Ports
Serial ATA Connectors
IDE1/2 Hard Disk Drive Connectors
IPMI 2.0 Connector
System Management Bus Header
Floppy Drive Connector
SMB Power Connector
4-Pin 12V Power Connector (required connection)
Primary ATX 20-Pin Power Connector
8-Pin 12V CPU Power Connector (required conn.)
PWR LED (pins 1-3) / Speaker (pins 4-7) Header
Front Panel USB2/3 Headers
Front Control Panel Connector
Chassis Intrusion Header
Overheat LED
Alarm Rest Header (Default: On)
Wake-on-LAN Header
Wake-on-Ring Header
Universal Serial Bus Ports
Video (Monitor) Connector
5-11
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Figure 5-7. SUPER X6DHR-iG/X6DHR-XiG Layout*
(not drawn to scale)
J38
Keyboard
J1D1
J32
J1B1
DIMM 1A
Mouse
DIMM 1B
FAN1
JP9
DIMM 2A
CPU1
USB 0/1
DIMM 2B
DIMM 3A
DIMM 3B
COM1
DIMM 4A
JF1
DIMM 4B
FAN2
J4F4
J4F5
CPU2
E7520
®
X6DHR-iG
J6 J5
J3
J4
SXB-E x4
PCI-X 133 MHz
GLAN1
FAN4
FAN5
J11
SUPER
J12
BIOS
PCI-X 133 MHz
SXB-E x8
IDE #1
Floppy
ZCR
GLAN CTRL
IDE #2
IPMI 2.0
GLAN2
VGA
S I/O
Force PW-On
WOR
PXH
J14
ICH5R
RAGE-X
Battery
PXH
JPL1
JPG1
JD2
JP10
JP11
JWD OH JL1
COM2
JBT1
SPKR
JD1
Fan3
WOL
*Notes:
1. Jumpers not indicated are for manufacturer test purposes only - do not
change these settings!
2. The only difference between the X6DHR-iG and the X6DHR-XiG is that
the X6DHR-XiG has no SXB-E (Universal) PCI card slot support.
5-12
Chapter 5: Advanced Serverboard Setup
X6DHR-iG/X6DHR-XiG Quick Reference
Jumper
Description
Default Setting
J4F4/J4F5
JBT1
JP10
JPG1
JPL1
JWD
Memory Speed Select
CMOS Clear
3rd PWR Supply Alarm En/Disable
VGA Enable/Disable
GLAN Enable/Disable
Watch Dog
Closed (DDR333)
See Section 5-9
Open (Disabled)
Pins 1-2 (Enabled)
Pins 1-2 (Enabled)
Pins 1-2 (Reset)
Connector
Description
COM1/COM2
DIMM#1A-DIMM#4B
FAN#1-5
GLAN1/2
J3/J4
J5/J6
J9
J11
J12
J32
J38
J1B1
J1D1
JD1
JD2
JF1
JL1
JOH1
JP9
JP11
JWOL
JWOR
USB0/1
VGA
COM1/COM2 Serial Port Connector/Header
Memory (SDRAM) Slots
Onboard CPU Fan/Chassis Fan Headers
Gigabit Ethernet Ports
SATA0/1 Connectors
IDE1/2 Hard Disk Drive Connectors
IPMI 2.0 Connector
System Management Bus Header
Floppy Drive Connector
SMB Power Connector
4-Pin 12V Power Connector (required connection)
Primary ATX 20-Pin Power Connector
8-Pin 12V CPU Power Connector (required conn.)
PWR LED (pins 1-3) / Speaker (pins 4-7) Header
Front Panel USB Headers
Front Control Panel Connector
Chassis Intrusion Header
Overheat LED
3rd Power Supply Fail Detect Header
Alarm Rest Header (Default: On)
Wake-on-LAN Header
Wake-on-Ring Header
Universal Serial Bus Ports
Video (Monitor) Port
5-13
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
5-8
Connector Definitions
ATX Power Connector
ATX 20-pin Power Connector
Pin Definitions (J1B1)
The X6DHR-iG2/X6DHR-iG/X6DHRXiG includes a 20-pin main power
supply connector (J1B1) and a 4pin 12V PWR connector (J38).
Both connections are required.
These power connectors meet the
SSI EPS 12V specification. See
the table on the right for pin definitions. For J38, please refer to the
item listed below.
Pin #
11
12
13
14
15
16
17
18
19
20
Definition Pin #
+3.3V
1
-12V
2
COM
3
PS_ON
4
COM
5
COM
6
COM
7
-5V
8
+5V
9
+5V
10
+12V 4-pin Connector
(J38)
Required
Connection
Processor Power
Connector
In addition to the Primary ATX
power connector (above), the 12v
8-pin processor power connector
at J1D1 must also be connected to
your power supply. See the table
on the right for pin definitions.
Required
Connection
Pins # Definition
1 & 2 Ground
3&4
+12 V
CPU 8-pin PWR
Connector (J1D1)
Pins Definition
1 thru 4 Ground
5 thru 8
+12v
NMI Button
The non-maskable interrupt button
header is located on pins 19 and 20
of JF1. Refer to the table on the right
for pin definitions.
NMI Button Pin
Definitions (JF1)
Pin
Number
Definition
19
Control
20
Ground
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for pin
definitions.
5-14
PWR_LED Pin Definitions
(JF1)
Pin
Number
Definition
15
Vcc
16
Control
Definition
+3.3V
+3.3V
COM
+5V
COM
+5V
COM
PW-OK
5VSB
+12V
Chapter 5: Advanced Serverboard Setup
HDD LED
The HDD LED connection is located
on pins 13 and 14 of JF1. Attach the
hard drive LED cable to display
hard drive activity. See the table
on the right for pin definitions.
HDD LED Pin
Definitions
(JF1)
Pin
Number Definition
13
Vcc
14
HD Active
NIC1/NIC2 LED
The NIC (Network Interface Controller) LED connection for GLAN1
is located on pins 11 and 12 of
JF1 and the connection for GLAN2
is on pins 9 and 10. Attach NIC
LED cables to display network activity. Refer to the table on the
right for pin definitions.
Overheat/Fan Fail LED
Connect an LED to pins 7 and 8 of
JF1 to provide warning of a processor overheating or fan failure.
The LED will flash/stay on as long
as the fan fail/overheat condition
exists. Refer to the table on the
right for pin definitions.
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Refer
to the table on the right for pin definitions.
5-15
NIC1/2 LED Pin
Definitions
(JF1)
Pin
Number Definition
Vcc
9/11
GND
10/12
Overheat (OH) LED
Pin Definitions
(JF1)
Pin
Number Definition
7
Vcc
8
GND
Power Fail LED Pin
Definitions
(JF1)
Pin
Number Definition
5
Vcc
6
GND
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Reset Button
Reset Pin
Definitions
(JF1)
The Reset Button connection is located on pins 3 and 4 of JF1. Attach
it to the hardware reset switch on the
computer case. Refer to the table on
the right for pin definitions.
Pin
Number Definition
3
Reset
4
Ground
Power Button
Power Button
Connector
Pin Definitions
(JF1)
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will
power on/off the system. To turn off
the power when set to suspend
mode, depress the button for at least
4 seconds. Refer to the table on the
right for pin definitions.
Pin
Number Definition
PW_ON
1
Ground
2
Chassis Intrusion
Chassis Intrusion
Pin Definitions (JL1)
Pin
Number
Definition
1
Intrusion Input
2
Ground
A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion.
USB Pin Definitions
USB0/1 (Backpanel USB)
Universal Serial Bus
(USB0/1, JD2)
There are two Universal Serial
Bus ports (USB0/1) located on the
I/O backpanel and an additional
two (USB2/3) next to the CMOS
Clear pads (JBT1). USB2/3 can be
used to provide front side chassis
access (cables not included). See
the tables on the right for pin definitions.
5-16
Pin# Definition
1
+5V
2
P03
P0+
4 Ground
USB2/3 (JD2)
Pin
Number
1
3
5
7
Definition
+5V
POPO+
Ground
Pin
Number
2
4
6
8
10
Definition
+5V
POPO+
Ground
Ground
Chapter 5: Advanced Serverboard Setup
Fan Headers
There are five fan headers (FAN1FAN5) on the serverboard. See
the table on the right for pin definitions.
Fan Header Pin Definitions
Pin #
Definition
1
Ground (black)
2
+12V (red)
3
Tachometer
4
PWR_Control
Caution: These fan headers
use DC power.
Note: These fan headers are 4pin fans. Pins#1-#3 of the fan
headers are backward compatible
with traditional 3-pin fans. Fan
speed is controlled by Thermal
Management via a Hardware Monitor and BIOS (Advanced Setting).
The default setting is disabled.
When using a Thermal Management setting, please use all 3-pin
fans or all 4-pin fans on the
serverboard. Do not use 3-pin
fans and 4-pin fans on the same
board.
Serial Ports
Serial Port Pin Definitions
(COM1, COM2)
The COM1 serial port is located on
the backplane and the COM2
header is located on the corner of
the board near the FAN3 header.
See the table on the right for pin
definitions.
ATX PS/2 Keyboard and
PS/2 Mouse Ports
Pin Number Definition Pin Number Definition
1
DCD
6
CTS
2
DSR
7
DTR
3
Serial In
8
RI
4
RTS
9
Ground
5
Serial Out
10
NC
PS/2 Keyboard
and Mouse Port
Pin Definitions
The ATX PS/2 keyboard and PS/2
mouse are located on the
backplane. See the table at right
for pin definitions. (See Figure 53 for the location of each port.)
5-17
Pin
Number Definition
Data
1
NC
2
Ground
3
VCC
4
Clock
5
NC
6
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Power LED/Speaker
Speaker Connector Pin
Definitions (JD1)
On the JD1 header, pins 1-3 are for
a power LED and pins 4-7 are for
the speaker. See the table on the
right for speaker pin definitions.
Pin
Number Function
Definition
4
+
Red wire, Speaker data
5
Key
No connection
6
Key
7
Speaker data
Note: The speaker connector pins
are for use with an external
speaker. If you wish to use the
onboard speaker, you should close
pins 6-7 with a jumper.
Wake-On-Ring
Wake-on-Ring
Pin Definitions
(JWOR)
The Wake-On-Ring header (designated JWOR) allows your computer
to receive and "wake-up" by an incoming call to the modem when in
suspend state. See the table on the
right for pin definitions. You must
have a Wake-On-Ring card and cable
to use this feature.
Pin
Number Definition
1
Ground
2
Wake-up
Wake-On-LAN
The Wake-On-LAN header is located
at JWOL. See the table on the right
for pin definitions. You must enable
the LAN Wake-Up setting in BIOS to
use this function. (You must also
have a LAN card with a Wake-OnLAN connector and cable.)
5-18
Wake-On-LAN Pin
Definitions (JWOL)
Pin
Number
1
2
3
Definition
+5V Standby
Ground
Wake-up
Chapter 5: Advanced Serverboard Setup
3rd Power Supply Fail
Detect Header
Power Fail
Pin Definitions (JP9)
Connect a cable from your power
supply to the header at JP9 to provide warning of power supply failure. The warning signal is passed
through the PWR_LED pin to indicate on the control panel that a
power supply has failed. See the
table on the right for pin definitions.
Pin
Number
1
2
3
4
Definition
P/S 1 Fail Signal
P/S 2 Fail Signal
P/S 3 Fail Signal
Reset (from MB)
Note: This feature is only available when
using redundant Supermicro power supplies.
SMB (I2 C) Connector
An I 2C connector at J11 (located
near the battery on the X6DHR-iG2
and near the IPMI header on the
X6DHR-iG/X6DHR-XiG) monitors
the status of the PWR supply, the
fans and the system temperature.
SMB PWR
Pin Definitions (J27)
Pin #
1
2
3
4
5
Definition
Clock
SMB Data
N/A
N/A
N/A
Overheat LED (JOH1)
Connect an LED to the JOH1
header to provide warning of
chassis overheating. See the
table on the right for pin definitions.
GLAN1/2 (Ethernet Ports)
Two gigabit Ethernet ports (designated GLAN1 and GLAN2) are located on the I/O backplane. These
ports accept RJ45 type cables.
5-19
Overheat LED
Pin Definitions (JOH1)
Pin
Number
1
2
Definition
+5V
OH Active
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
5-9
Jumper Settings
Explanation of
Jumpers
Connector
Pins
To modify the operation of the
serverboard, jumpers can be
used to choose between
optional settings.
Jumpers
create shorts between two pins
to change the function of the
connector. Pin 1 is identified
with a square solder pad on
the printed circuit board. See
the serverboard layout pages
for jumper locations.
3
2
1
3
2
1
Jumper
Cap
Setting
Pin 1-2 short
Note: On two pin jumpers,
"Closed" means the jumper is
on and "Open" means the
jumper is off the pins.
CMOS Clear
JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper consists of contact pads to prevent accidentally
clearing the contents of CMOS.
To clear CMOS,
1) First power down the system and unplug the power cord(s).
2) With the power disconnected, short the CMOS pads with a metal object
such as a small screwdriver.
3) Remove the screwdriver (or shorting device).
4) Reconnect the power cord(s) and power on the system.
Note: Do not use the PW_ON connector to clear CMOS.
5-20
Chapter 5: Advanced Serverboard Setup
3rd Power Supply Alarm
Enable/Disable
Power Supply
Alarm Enable/Disable
Jumper Settings (JP10)
The system can notify you in the
event of a power supply failure.
This feature assumes that three
power supply units are installed in
the chassis with one acting as a
backup. If you only have one or
two power supply units installed,
you should disable this (the default
setting) with JP10 to prevent false
alarms. See the table on right for
pin definitions.
Jumper
Position
Open
Closed
Definition
Disabled
Enabled
VGA
Enable/Disable
Jumper Settings
(JPG1)
VGA Enable/Disable
JPG1 enables or disables the VGA
Connector on the motherboard.
See the table on the right for
jumper settings. The default setting is enabled.
Jumper
Position
Pins 1-2
Pins 2-3
Definition
Enabled
Disabled
Watch Dog Enable/Disable
JWD enables the Watch Dog function. Watch Dog is a system monitor that can reboot the system when
a software application is "hung up".
Pins 1-2 will cause WD to reset the
system if an application is hung up.
Pins 2-3 will generate a nonmaskable interrupt signal for the application that is hung up. See the
table on the right for jumper settings.
Watch Dog can also be enabled via
BIOS.
Note: When enabled, the user needs
to write his own application software
in order to disable the WD Timer.
5-21
Watch Dog
Jumper Settings (JWD)
Jumper
Position
Pins 1-2
Pins 2-3
Open
Definition
WD to Reset
WD to NMI
Disabled
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
GLAN
Enable/Disable
Jumper Settings
(JPL1)
GLAN Enable/Disable
Change the setting of jumper JPL1
to enable or disable the onboard
GLAN ports (GLAN1 and GLAN2)
on the serverboard. See the table
on the right for jumper settings.
The default setting is enabled.
Jumper
Position
Pins 1-2
Pins 2-3
Memory Speed Select
Definition
Enabled
Disabled
Memory Speed Select
Jumper Settings
(J4F4, J4F5)
Use J4F4 and J4F5 to select the
speed of the system memory. See
the table on the right for jumper
definitions. The default setting is
closed (DDR333).
J4F4
Closed
J4F5
Closed
Open
Open
Memory Speed
333 MHz
(DDR333)
266 MHz
(DDR266)
Note: if these jumpers are not set
correctly, you may experience
problems with your video display.
5-10 Onboard Indicators
GLAN LEDs
Each Ethernet port has two LEDs.
The yellow LED indicates activity
while the other LED may be green,
orange or off to indicate the speed
of the connection. See the table
on the right for the functions associated with this second LED.
5-22
Gb LAN Right LED
Indicator
LED
Color
Off
Green
Orange
Definition
No Connection
100 MHz
1 GHz
Chapter 5: Advanced Serverboard Setup
5-11 Floppy and Hard Disk Drive Connections
Note the following when connecting the floppy and hard disk drive cables:
• The floppy disk drive cable has seven twisted wires.
• A red mark on a wire typically designates the location of pin 1.
• A single floppy disk drive ribbon cable has 34 wires and two connectors
to provide for two floppy disk drives. The connector with twisted wires
always connects to drive A, and the connector that does not have
twisted wires always connects to drive B.
Floppy Connector
The floppy connector is located
on J12. See the table below for
pin definitions.
Floppy Connector Pin Definitions (J12)
Pin Number
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
Function
GND
GND
Key
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
5-23
Pin Number
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
Function
FDHDIN
Reserved
FDEDIN
IndexMotor Enable
Drive Select BDrive Select AMotor Enable
DIRSTEPWrite DataWrite GateTrack 00Write ProtectRead DataSide 1 SelectDiskette
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
IDE Connectors
There are no jumpers to
configure the onboard IDE#1
and #2 connectors. See the
table below for pin definitions.
IDE Connector Pin Definitions
(J5, J6)
Pin Number
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
Function
Reset IDE
Host Data 7
Host Data 6
Host Data 5
Host Data 4
Host Data 3
Host Data 2
Host Data 1
Host Data 0
GND
DRQ3
I/O WriteI/O ReadIOCHRDY
DACK3IRQ14
Addr 1
Addr 0
Chip Select 0
Activity
5-24
Pin Number
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
Function
GND
Host Data 8
Host Data 9
Host Data 10
Host Data 11
Host Data 12
Host Data 13
Host Data 14
Host Data 15
Key
GND
GND
GND
BALE
GND
IOCS16GND
Addr 2
Chip Select 1GND
Chapter 6: Advanced Chassis Setup
Chapter 6
Advanced Chassis Setup
This chapter covers the steps required to install components and perform
maintenance on the SC812i-420 chassis. For component installation, follow
the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step.
Tools Required
The only tool you will need to install components and perform maintenance
is a Philips screwdriver.
6-1
Static-Sensitive Devices
Electricstatic discharge (ESD) can damage electronic components. To prevent damage to any printed circuit boards (PCBs), it is important to handle
them very carefully. The following measures are generally sufficient to
protect your equipment from ESD damage.
Precautions
z Use a grounded wrist strap designed to prevent static discharge.
z Touch a grounded metal object before removing any board from its antistatic bag.
z Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.
z When handling chips or modules, avoid touching their pins.
z Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.
z For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting
fasteners and the serverboard.
6-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Figure 6-1.
Slim Floppy Drive
Chassis: Front and Rear Views
System LEDs
Slim CD-ROM Drive
IDE Drives
Power Supply
USB0/1 Ports
Mouse/Keyboard Ports
6-2
COM2 Port
System Reset
GLAN (Ethernet) Ports
COM1 Port
USB Ports
Main Power
VGA Port
PCI Expansion Slots
Control Panel
The control panel (located on the front of the chassis) must be connected
to the JF1 connector on the serverboard to provide you with system status
indications. A ribbon cable has bundled these wires together to simplify the
connection. Connect the cable from JF1 on the serverboard to the appropriate header on the Control Panel PCB (printed circuit board). Make sure
the red wire plugs into pin 1 on both connectors. Pull all excess cabling out
of the airflow path.
The control panel LEDs inform you of system status. See "Chapter 3:
System Interface" for details on the LEDs and the control panel buttons.
Details on JF1 can be found in "Chapter 5: Advanced Serverboard Setup."
6-2
Chapter 6: Advanced Chassis Setup
6-3
System Fans
Two 10-cm blower fans provide all the cooling needed for the SuperServer
6014H-i2/6014H-i/6014H-Xi. It is very important that the chassis top cover
is properly installed and making a good seal in order for the cooling air to
circulate properly through the chassis and cool the components. See Figure 6-2.
Fan speed is DC controlled by a setting in BIOS (see page 7-17). The
recommended setting for the 6014H-i2/6014H-i/6014H-Xi is "3-pin (Server)".
System Fan Failure
If a fan fails, the ambient air temperature in the chassis will rise and activate the Overheat/Fan Fail LED on the control panel. Replace any failed fan
immediately with the same type and model. You must power down the
system before replacing a cooling fan (removing the power cord is also
recommended as a safety precaution).
Replacing System Cooling Fans
1.
Removing a fan:
After first turning off the power to the system, remove the chassis cover
and unplug the fan cable from the motherboard. Unscrew the failed
blower fan from the chassis and pull it completely out from the
serverboard.
2.
Installing a new fan:
Replace the failed fan with an identical 10-cm, 12 volt fan (available from
Supermicro: p/n FAN-0071). Install the new fan in its proper place in the
chassis by positioning it on the two mounting posts. Secure the fan to
the chassis with the screws you removed previously, then attach the fan
wires to the same chassis fan header you removed it from. Make sure
the air seal under the fan is properly installed and creating a good seal.
Power up the system and check that the fan is working properly and that
the Overheat/Fan Fail LED on the control panel has turned off. Finish by
replacing the chassis cover.
6-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Figure 6-2. System Cooling Fans (with optional front bezel shown)
10-cm Blower Fans
6-4
Drive Bay Installation/Removal
Removing the Front Bezel
If your system has a front bezel (optional) attached to the chassis, you
must first remove it to gain access to the drive bays. To remove the bezel,
first unlock the front of the chassis then press the release knob. Carefully
remove the bezel with both hands. A filter located within the bezel can be
removed for replacement/cleaning. It is recommended that you keep a maintenance log of filter cleaning/replacement, since its condition will affect the
airflow throughout the whole system.
6-4
Chapter 6: Advanced Chassis Setup
Accessing the Drive Bays
IDE Drives: IDE drives may be installed and removed from the front of the
chassis without removing the chassis cover, however you will need to
power down the system when installing or removing IDE drives. Proceed to
the next page for instructions.
CD-ROM/Floppy Disk Drives: For installing/removing a CD-ROM or floppy disk
drive, you will need to power down the system and remove the top cover
of the chassis to gain access to the inside of the system. Proceed to the
"CD-ROM and Floppy Drive Installation" section later in this chapter for instructions.
Note: Only a "slim" type CD-ROM and floppy drive will fit into the 6014H-i2/
6014H-i/6014H-Xi.
Removing the Top Chassis Cover
First, release the retention screws that secure the server unit to the rack.
Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click"). Next, depress the two buttons on the top of
the chassis to release the top cover and at the same time, push the cover
away from you until it stops. You can then lift the top cover from the
chassis to gain full access to the inside of the server.
6-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
IDE Drive Installation
1.
Mounting an IDE drive in a drive carrier:
The IDE drives are mounted in drive carriers to simplify their installation
and removal from the chassis. These carriers also help promote proper
airflow for the system. For this reason, even empty carriers without IDE
drives installed must remain in the chassis. To add a new IDE drive,
install a drive into the carrier with the printed circuit board side tfacing
down so that the mounting holes align with those in the carrier. Secure
the drive to the carrier with four screws, as shown in Figure 6-3.
2.
Installing/removing IDE drives
The three IDE drive bays are located in the front of the chassis in
carriers that make them easily accessible for installation and removal.
The IDE drives are not hot-swap units, meaning system power must be
turned off before installing and/or removing them. To install or remove a
drive, first power down the system and then push the colored release
button to unlock the carrier. Swing the handle fully out and use it to pull
the IDE drive carrier straight out (see Figure 6-4).
Figure 6-3. Installing an IDE Drive into a Drive Carrier
6-6
Chapter 6: Advanced Chassis Setup
Figure 6-4. Removing an IDE Drive from the Chassis
6-7
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
CD-ROM and Floppy Drive Installation
The top cover of the chassis must be opened to gain full access to the CDROM and floppy drive bays. The 6014H-i2/6014H-i/6014H-Xi accomodates
only slim CD-ROM and floppy drives. Side mounting brackets are needed to
mount a slim CD-ROM drive in the 6014H-i2/6014H-i/6014H-Xi server.
You must power down the system before installing or removing a floppy or
CD-ROM drive. Then, release the retention screws that secure the server
unit to the rack. Grasp the two handles on either side and pull the unit
straight out until it locks (you will hear a "click"). Next, depress the two
buttons on the top of the chassis to release the top cover and at the same
time, push the cover away from you until it stops. You can then lift the top
cover from the chassis to gain full access to the inside of the server.
With the chassis cover removed, unplug the power and data cables from
the drive you want to remove. Then locate the locking tab at the rear of the
drive. It will be on the left side of the drive when viewed from the front of
the chassis. Pull the tab away from the drive and push the drive unit out
the front of the chassis. Add a new drive by following this procedure in
reverse order. You may hear a faint *click* of the locking tab when the
drive is fully inserted. Remember to reconnect the data and power cables
to the drive before replacing the chassis cover and restoring power to the
system. Please be aware of the following:
• The floppy disk drive cable has seven twisted wires.
• A color mark on a cable typically designates the location of pin 1.
• A single floppy disk drive ribbon cable has 34 wires and two connectors
to provide for two floppy disk drives. The connector with twisted wires
always connects to drive A, and the connector that does not have
twisted wires always connects to drive B.
6-8
Chapter 6: Advanced Chassis Setup
6-5
Power Supply
The SuperServer 6014H-i2/6014H-i/6014H-Xi has a single 420 watt power
supply, which is auto-switching capable. This enables it to automatically
sense and operate at a 100v - 240v input voltage.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need
to replace the unit. Replacement units can be ordered directly from
Supermicro (see contact information in the Preface). As there is only one
power supply unit in the 6014H-i2/6014H-i/6014H-Xi, power must be completely removed from the server before removing and replacing the power
supply unit for whatever reason.
Removing/Replacing the Power Supply
1.
Removing the power supply:
First shut-down the operating system. Then turn the power switch on
the control panel off and unplug the power cord from the server. You
may have to pull the server out from the rack to remove the top cover.
To remove the top chassis cover, press the two release buttons on the
cover (near the front) and then push the cover rearward about one inch
before lifting it off. Locate the power connectors leading from the power
supply to the motherboard and disconnect them. Next, push the release
tab on the back of the power supply to the right and pull the unit straight
out of the chassis with the handle provided.
2.
Installing a new power supply:
Replace the failed unit with another unit of the same input voltage, output
voltage and wattage. It is highly recommended to replace it with exactly
the same model power supply (p/n: PWS-0053-20). Carefully insert the
new unit into the empty power supply bay and push it completely into the
chassis. Reconnect all the power connectors to the same headers you
removed the old power supply cables from, making sure you reroute the
power cables so that they do not block system airflow. Replace the
chassis top cover and reposition the unit back into the rack. Finish by
reconnecting the power cord and depressing the power button on the
chassis front control panel.
6-9
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Notes
6-10
Chapter 7: BIOS
Chapter 7
BIOS
7-1
Introduction
This chapter describes the Phoenix BIOS™ Setup utility for the X6DHR-iG2/
X6DHR-iG/X6DHR-XiG. The Phoenix BIOS is stored in a flash chip and can
be easily upgraded using a floppy disk-based program. Due to periodic
changes in the BIOS, some settings may have been added or deleted that
might not yet be recorded in this manual. Please refer to the Manual Download area of the Supermicro web site for any such changes.
Starting the Setup Utility
To enter the BIOS Setup Utility, hit the <Delete> key while the system is
booting-up. (In most cases, the <Delete> key is used to invoke the BIOS setup
screen. There are a few cases when other keys are used, such as <F1>,
<F2>, etc.)
Each main BIOS menu option is described in this manual. The Main BIOS
screen has two main frames. The left frame displays all the options that can
be configured. “Grayed-out” options cannot be configured. The right frame
displays the key legend. Above the key legend is an area reserved for a
text message. When an option is selected in the left frame, it is highlighted
in white. Often a text message will accompany it. (Note: BIOS has default
text messages built in. Supermicro retains the option to include, omit, or
change any of these text messages.) Options printed in Bold are the
default settings.
The BIOS setup/utility uses a key-based navigation system called hot keys.
Most of these hot keys (<F1>, <F10>, <Enter>, <ESC>, <Arrow> keys, etc.)
can be used at any time during the setup navigation process.
Note: fan speed is controlled by the "Auto Fan Control" setting in BIOS.
The recommended setting for the 6014H-i2/6014H-i/6014H-Xi is "3-pin
(Server)" If you load the BIOS default settings this setting may change.
Therefore, when loading BIOS defaults you should reenter BIOS setup and
change this setting back to "3-pin (Server)", then save and exit (see page
7-17).
7-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
7-2
Running Setup
*Default settings are in bold text unless otherwise noted.
The BIOS setup options described in this section are selected by choosing the appropriate text from the main BIOS Setup screen. All displayed
text is described in this section, although the screen display is often all
you need to understand how to set the options (see on next page).
When you first power on the computer, the Phoenix BIOS™ is immediately
activated.
While the BIOS is in control, the Setup program can be activated in one of two
ways:
1. By pressing <Delete> immediately after turning the system on, or
2. When the message shown below appears briefly at the bottom of the
screen during the POST (Power On Self-Test), press the <Delete> key to
activate the main Setup menu:
Press the <Delete> key to enter Setup
7-3
Main BIOS Setup
All main Setup options are described in this section. The main BIOS Setup screen
is displayed below.
Use the Up/Down arrow keys to move among the different settings in each menu.
Use the Left/Right arrow keys to change the options for each setting.
Press the <Esc> key to exit the CMOS Setup Menu. The next section describes
in detail how to navigate through the menus.
Items that use submenus are indicated with the
press the <Enter> key to access the submenu.
7-2
icon. With the item highlighted,
Chapter 7: BIOS
Main BIOS Setup Menu
Main Setup Features
System Time
To set the system date and time, key in the correct information in the
appropriate fields. Then press the <Enter> key to save the data.
System Date
Using the arrow keys, highlight the month, day and year fields and enter
the correct data. Press the <Enter> key to save the data.
BIOS Date
This feature allows BIOS to automatically display the BIOS date.
7-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Legacy Diskette A
This setting allows the user to set the type of floppy disk drive installed as
diskette A. The options are Disabled, 360Kb 5.25 in, 1.2MB 5.25 in, 720Kb
3.5 in, 1.44/1.25MB, 3.5 in and 2.88MB 3.5 in.
Parallel ATA
This setting allows the user to enable or disable the funciton of Parallel
ATA. The options are Disabled, Channel 0, Channel 1 and Both.
Serial ATA
This setting allows the user to enable or disable the funciton of Serial ATA.
The options are Disabled and Enabled.
Serial ATA RAID Enable
Select Enable to enable Serial ATA RAID Functions. (For the Windows OS
environment, use the RAID driver if this feature is set to "Enabled". If
"disabled", use the "Non-RAID" driver.)
Native Mode Operation
This option allows the user to select the Native Mode for ATA. Some
Operating Systems are not supported by the Native Mode. The options are:
Serial ATA, Parallel ATA, Auto, and Both.
IDE Channel 0 Master/Slave, IDE Channel 1 Master/Slave, IDE
Channel 2 Master, IDE Channel 3 Master
These settings allow the user to set the parameters of IDE Channel 0
Master/Slave, IDE Channel 1 Master/Slave, IDE Channel 2 Master, IDE
Channel 3 Master slots. Hit <Enter> to activate the following sub-menu
screen for detailed options of these items. Set the correct configurations
accordingly. The items included in the sub-menu are:
7-4
Chapter 7: BIOS
Type
Selects the type of IDE hard drive. The options are Auto (allows BIOS
to automatically determine the hard drive's capacity, number of heads,
Sectors, Maximum Capacity, LBA Format, ect.). Enter a number from 139 to select a predetermined type of hard drive, CD-ROM and ATAPI
Removable. The option- "User" will allow the user to enter the parameters
of the HDD installed at this connection. The option-"Auto" will allow BIOS
to automatically configure the parameters of the HDD installed at the
connection. Choose the option"1-39" to select a pre-determined HDD
type. Select CD-ROM if a CD-ROM drive is installed. Select ATAPI if a
removable disk drive is installed.
7-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Multi-Sector Transfers
Select the number of transfer sectors. The options are Disabled, 2, 4, 6,
8 and 16 Sectors.
LBA Mode Control
This item determines whether Phoenix BIOS will access the IDE Primary
Master Device via LBA mode. The options are Disabled and Enabled.
32 Bit I/O
Selects 32 Bit I/O operation. The options are Enabled and Disabled.
Transfer Mode
Selects the transfer mode. The options are Standard, Fast PIO1, Fast
PIO2, Fast PIO3, Fast PIO4, FPIO3/DMA1 and FPIO4/DMA2.
Ultra DMA Mode
Selects Ultra DMA Mode. The options are Disabled, Mode 0, Mode 1,
Mode 2, Mode 3, Mode 4, Mode 5 and Mode 6.
System Memory
This display informs you how much system memory is recognized as being
present in the system.
Extended Memory
This display informs you how much extended memory is recognized as
being present in the system.
7-6
Chapter 7: BIOS
7-4
Advanced Setup
Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow
keys. You should see the following display. The items with a triangle beside
them have sub menus that can be accessed by highlighting the item and pressing
<Enter>. Options for PIR settings are displayed by highlighting the setting option
using the arrow keys and pressing <Enter>. All Advanced BIOS Setup options
are described in this section.
Boot Features
Access the submenu to make changes to the following settings.
Quick Boot Mode
If enabled, this feature will speed up the POST (Power On Self Test) routine
after the computer is turned on. The settings are Enabled and Disabled. If
Disabled, the POST routine will run at normal speed.
Quiet Boot
This setting allows you to Enable or Disable the diagnostic screen during
boot-up.
7-7
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
ACPI Mode
Use the setting to determine if you want to employ ACPI (Advanced
Configuration and Power Interface) power management on your system.
The options are Yes and No.
Power Button Behavior
If set to Instant-Off, the system will power off immediately as soon as the
user hits the power button. If set to 4-sec, the system will power off when
the user presses the power button for 4 seconds or longer. The options
are instant-off and 4-sec override.
Power Loss Control
This setting allows you to choose how the system will react when power
returns after an unexpected loss of power. The options are Stay On, Power
Off and Last State.
Watch Dog
Use this setting to Enable or Disable the Watch Dog feature.
Summary Screen
This setting allows you to Enable or Disable the summary screen.
Memory Cache
Cache System BIOS Area
This setting allows you to designate a reserve area in the system
memory to be used as a System BIOS buffer to allow the BIOS write
(cache) its data into this reserved memory area. Select "Write Protect"
to enable this function, and this area will be reserved for BIOS ROM
access only. Select "Uncached" to disable this function and make this
area available for other devices.
Cache Video BIOS Area
This setting allows you to designate a reserve area in the system
memory to be used as a Video BIOS buffer to allow the BIOS write
7-8
Chapter 7: BIOS
(cache) its data into this reserved memory area. Select "Write Protect"
to enable the function and this area will be reserved for BIOS ROM
access only. Select "Uncached" to disable this function and make this
area available for other devices.
Cache Base 0-512K
If enabled, this feature will allow the data stored in the base memory
area: block 0-512K to be cached (written) into a buffer, a storage area
in the Static DRM (SDROM) or written into L1, L2, L3 cache inside the
CPU to speed up CPU operations . Select "Uncached" to disable this
funciton. Select "Write Through" to allow data to be cached into the
buffer and written into the system memory at the same time. Select
"Write Protect" to prevent data from being written into the base memory
area of Block 0-512K. Select "Write Back" to allow CPU to write data
back directly from the buffer without writing data to the System Memory
for fast CPU data processing and operation. The options are
"Uncached", "Write Through", "Write Protect", and "Write Back".
Cache Base 512K-640K
If enabled, this feature will allow the data stored in the memory area:
512K-640K to be cached (written) into a buffer, a storage area in the
Static DRM (SDROM) or written into L1, L2, L3 cache inside the CPU to
speed up CPU operations . Select "Uncached" to disable this funciton.
Select "Write Through" to allow data to be cached into the buffer and
written into the system memory at the same time. Select "Write Protect"
to prevent data from being written into the base memory area of Block
0-512K. Select "Write Back" to allow CPU to write data back directly from
the buffer without writing data to the System Memory for fast CPU data
processing and operation. The options are "Uncached", "Write Through",
"Write Protect", and "Write Back".
Cache Extended Memory
If enabled, this feature will allow the data stored in the extended memory
area to be cached (written) into a buffer, a storage area in the Static
DRM (SDROM) or written into L1, L2, L3 cache inside the CPU to speed
up CPU operations . Select "Uncached" to disable this funciton. Select
"Write Through" to allow data to be cached into the buffer and written
into the system memory at the same time. Select "Write Protect" to
prevent data from being written into the base memory area of Block 0-
7-9
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
512K. Select "Write Back" to allow CPU to write data back directly from
the buffer without writing data to the System Memory for fast CPU data
processing and operation. The options are "Uncached", "Write Through",
"Write Protect", and "Write Back.
PCI Configuration
Access the submenu to make changes to the following settings for PCI
devices.
Onboard GLAN (Gigabit- LAN) OPROM Configure
Enabling this option provides the capability to boot from GLAN.
options are Disabled and Enabled.
The
Onboard SCSI OPROM Configure
Enabling this option provides the capability to boot from SCSI HDD. The
options are Disabled and Enabled.
Reset Configuration Data
If set to Yes, this setting clears the Extended System Configuration Data(ESCD) area. The options are Yes and No.
Frequency for RAID-SLOT/SCSI
This option allows the user to change the bus frequency for the devices
installed in the slot indicated. The options are Auto, PCI 33 MHz, PCI 66
MHz, PCI-X 66 MHz, PCI-X 100 MHz, and PCI-X 133 MHz.
Frequency for G-LAN
This option allows the user to change the bus frequency of the devices
installed in the slot indicated. The options are Auto, PCI 33 MHz, PCI 66
MHz, PCI-X 66 MHz, PCI-X 100 MHz, and PCI-X 133 MHz.
Frequency for PCI-X #1/Frequency for PCI-X #2
This option allows the user to change the bus frequency of the devices
installed in the slot indicated. The options are Auto, PCI 33 MHz, PCI 66
MHz, PCI-X 66 MHz, PCI-X 100 MHz, and PCI-X 133 MHz.
7-10
Chapter 7: BIOS
PCI-X 133MHz Slot #1/Slot#2, PCI-Expx8 Slot#3/PCI-Expx4
Slot#4
Access the submenu for each of the settings above to make changes to
the following:
Option ROM Scan
When enabled, this setting will initialize the device expansion ROM.
Enable Master
This setting allows you to enable the selected device as the PCI bus
master. The options are Enabled and Disabled.
Latency Timer
This setting allows you to set the clock rate for Bus Master.A highprioity, high-throughout device may benefit from a greater Clock rate.
The options are Default, 0020h, 0040h, 0060h, 0080h, 00A0h, 00C0h,
and 00E0h.
For Unix, Novell and other Operating Systems, please
select the option:"other". If a drive fails after the installation of a new
software , you might want to change this settiing and try again.
Different OS requires different Bus Master clock rate.
Large Disk Access Mode
This setting determines how large hard drives are to be accessed. The
options are DOS or Other (for Unix, Novellle NetWare and other operating
systems).
Advanced Chipset Control
Access the submenu to make changes to the following settings.
Force Compliance Mode Entry
This feature allows you to enable the PCI-Express Compliance 1.0 Mode.
The options are: Disabled or Enabled.
7-11
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Memory RAS Feature Control
Select this option to enable the Memory RAS Feature Control The options
are Miirroring, Sparing and Standard.
Clock Spectrum Feature
If "Enabled", BIOS will monitor the level of Electromagnetic Interference
caused by the components and will attempt to decrease the interference
whenever needed. The options are Enabled and Disabled.
DRAM Data Integrity Mode
If enabled, this feature allows the data stored in the DRMA memory to
be integrated for faster data processing. The options are 72-bit ECC,
144-bit ECC, Auto, Algorithms and Disabled.
ECC Error Type
This setting lets you select which type of interrupt to be activated as a
result of an ECC error. The options are None, NMI (Non-Maskable
Interrupt), SMI (System Management Interrupt) and SCI (System Control
Interrupt.)
SERR Signal Condition
This setting specifies the conditions required to be qualified as an ECC
error. The options are None, Single Bit, Multiple Bit and Both.
USB Function
This setting allows you to Enable or Disable all functions for the USB
devices specified.
Legacy USB Support
This setting allows you to enable support for Legacy USB devices. The
settings are Enabled and Disabled.
7-12
Chapter 7: BIOS
Advanced Processor Options
Access the submenu to make changes to the following settings.
CPU Speed
This is a display that indicates the speed of the installed processor.
Hyper-threading
This setting allows you to Enable or Disable the function of hyperthreading. Enabling hyper-threading results in increased CPU
performance. (Applicable for the XP systems.)
Machine Checking
This setting allows you to Enable or Disable Machine Checking.
Adjacent Cache Line Prefetch
The CPU fetches the cache line for 64 bytes if Disabled. The CPU fetches
both cache lines for 128 bytes as comprised if Enabled.
I/O Device Configuration
Access the submenu to make changes to the following settings.
7-13
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
KBC Clock Input
This setting allows you to select clock frequency for KBC. The options
are 6MHz, 8MHz, 12MHz and 16MHz.
On-board COM 1
This setting allows you to assign control of serial port A. The options
are Enabled (user defined), Disabled and Auto (BIOS controlled).
Base I/O Address
Select the base I/O address for serial port A. The options are 3F8,
2F8, 3E8 and 2E8.
Interrupt
Select the IRQ (interrupt request) for serial port A. The options are
IRQ3 and IRQ4.
On-board COM 2
This setting allows you to assign control of serial port B. The options
are Enabled (user defined), Disabled and Auto (BIOS controlled).
Mode
Specify the type of device that will be connected to serial port B. The
options are Normal, IR (for an infrared device) and ASK-IR.
Base I/O Address
Select the base I/O address for serial port B. The options are 3F8,
2F8, 3E8 and 2E8.
Interrupt
Select the IRQ (interrupt request) for serial port B. The options are
IRQ3 and IRQ4.
7-14
Chapter 7: BIOS
Parallel Port
This setting allows you to assign control of the parallel port. The options
are Enabled (user defined), Disabled and Auto (BIOS controlled).
Base I/O Address
Select the base I/O address for the parallel port. The options are 378,
278 and 3BC.
Interrupt
Select the IRQ (interrupt request) for the parallel port. The options
are IRQ5 and IRQ7.
Mode
Specify the parallel port mode.
directional, EPP and ECP.
The options are Output Only, Bi-
DMA Channel 1
Specify the DMA channel. The options are DMA1 and DMA3.
Floppy Disk Controller
This setting allows you to assign control of the floppy disk controller.
The options are Enabled (user defined), Disabled and Auto (BIOS
controlled).
Base I/O Address
Select the base I/O address for the parallel port.
Primary and Secondary.
7-15
The options are
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
DMI Event Logging
Access the submenu to make changes to the following settings.
Event Log Validity
This is a display, not a setting, informing you of the event log validity.
Event Log Capacity
This is a display, not a setting, informing you of the event log capacity.
View DMI Event Log
Highlight this item and press <Enter> to view the contents of the event
log.
Event Logging
This setting allows you to Enable or Disable event logging.
ECC Event Logging
This setting allows you to Enable or Disable ECC event logging.
Mark DMI Events as Read
Highlight this item and press <Enter> to mark the DMI events as read.
Clear All DMI Event Logs
Select Yes and press <Enter> to clear all DMI event logs. The options are
Yes and No.
Console Redirection
Access the submenu to make changes to the following settings.
COM Port Address
Specifies to redirect the console to On-board COM A or On-board COM
B. This setting can also be Disabled.
7-16
Chapter 7: BIOS
BAUD Rate
Select the BAUD rate for console redirection. The options are 300, 1200,
2400, 9600, 19.2K, 38.4K, 57.6K and 115.2K.
Console Type
Choose from the available options to select the console type for console
redirection. The options are VT100, VT100,8bit, PC-ANSI, 7bit, PCANSI,
VT100+, VT-UTF8.
Flow Control
Choose from the available options to select the flow control for
console redirection. The options are: None, XON/XOFF, and CTS/RTS.
Console Connection
Select the console connection: either Direct or Via Modem.
Continue CR after POST
Choose whether to continue with console redirection after the POST
routine. The options are On and Off.
Hardware Monitor
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds
of the onboard fans. If the option is set to "3-pin", the fan speed is controlled based upon the CPU die temperature. When the CPU die temperature
is higher, the fan speed will be higher as well. If the option is set to "4-pin",
the fan speed will be controlled by the Thermal Management Settings preconfigured by the user at this feature. Select "3-pin" if your chassis came
with 3-pin fan headers. Select "4-pin" if your chassis came with 4-pin fan
headers.
Select "Workstation" if your system is used as a Workstation.
Select "Server" if your system is used as a Server. Select "Disable" to
disable the fan speed control function to allow the onboard fans to run at
the full speed (12V) at all time. The options are Disable, 3-pin (Server),
3-pin (Workstation), 4-pin (Server) and 4-pin (Workstation).
The recommended setting for the 6014H-i2/6014H-i/6014H-Xi is "3-pin
(Server)".
7-17
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
7-5
Security
Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow
keys. You should see the following display. Security setting options are
displayed by highlighting the setting using the arrow keys and pressing <Enter>.
All Security BIOS settings are described in this section.
Supervisor Password Is:
This displays whether a supervisor password has been entered for the
system. Clear means such a password has not been used and Set means
a supervisor password has been entered for the system.
User Password Is:
This displays whether a user password has been entered for the system.
Clear means such a password has not been used and Set means a user
password has been entered for the system.
7-18
Chapter 7: BIOS
Set Supervisor Password
When the item "Set Supervisor Password" is highlighted, hit the <Enter> key.
When prompted, type the Supervisor's password in the dialogue box to set
or to change supervisor's password, which allows access to BIOS.
Set User Password
When the item "Set User Password" is highlighted, hit the <Enter> key.
When prompted, type the user's password in the dialogue box to set or to
change the user's password, which allows access to the system at bootup.
Fixed Disk Boot Sector
This setting may offer some protection against viruses when set to Write
Protect, which protects the boot sector on the hard drive from having a
virus written to it. The other option is Normal.
Password on Boot
This setting allows you to require a password to be entered when the
system boots up. The options are Enabled (password required) and
Disabled (password not required).
7-19
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
7-6
Boot
Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys.
You should see the following display. Highlighting a setting with a + or - will
expand or collapse that entry. See details on how to change the order and specs
of boot devices in the Item Specific Help window. All Boot BIOS settings are
described in this section.
Phoenix BIOS Setup Utility
Main
Advanced
Security
Boot
Exit
Item Specific Help
+Removable Devices
CD-ROM Drive
+Hard Drive
F1 Help
Esc Exit
↑↓
↔
Select Item
Select Menu
-/+ Change Values
Enter SelectSub-Menu
F9 Setup Defaults
F10 Save and Exit
+Removable Devices
Highlight and press <Enter> to expand the field. See details on how to
change the order and specs of devices in the Item Specific Help window.
CD-ROM Drive
See details on how to change the order and specs of the CD-ROM drive in
the Item Specific Help window.
+Hard Drive
Highlight and press <Enter> to expand the field. See details on how to
change the order and specs of hard drives in the Item Specific Help
window.
7-20
Chapter 7: BIOS
7-7
Exit
Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys.
You should see the following display. All Exit BIOS settings are described in this
section.
Exit Saving Changes
Highlight this item and hit <Enter> to save any changes you made and to
exit the BIOS Setup utility.
Exit Discarding Changes
Highlight this item and hit <Enter> to exit the BIOS Setup utility without saving
any changes you may have made.
Load Setup Defaults
Highlight this item and hit <Enter> to load the default settings for all items in
the BIOS Setup. These are the safest settings to use.
7-21
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Discard Changes
Highlight this item and hit <Enter> to discard (cancel) any changes you
made. You will remain in the Setup utility.
Save Changes
Highlight this item and hit <Enter> to save any changes you made. You will
remain in the Setup utility.
7-22
Appendix A: BIOS POST Messages
Appendix A
BIOS POST Messages
During the Power-On Self-Test (POST), the BIOS will check for problems. If a problem
is found, the BIOS will activate an alarm or display a message. The following is a list
of such BIOS messages.
Failure Fixed Disk
Fixed disk is not working or not configured properly. Check to see if fixed disk is
attached properly. Run Setup. Find out if the fixed-disk type is correctly identified.
Stuck key
Stuck key on keyboard.
Keyboard error
Keyboard not working.
Keyboard Controller Failed
Keyboard controller failed test. May require replacing keyboard controller.
Keyboard locked - Unlock key switch
Unlock the system to proceed.
Monitor type does not match CMOS - Run SETUP
Monitor type not correctly identified in Setup
Shadow Ram Failed at offset: nnnn
Shadow RAM failed at offset nnnn of the 64k block at which the error
was detected.
System RAM Failed at offset: nnnn
System RAM failed at offset nnnn of in the 64k block at which the error
was detected.
Extended RAM Failed at offset: nnnn Extended memory not
working or not configured properly at offset nnnn.
System battery is dead - Replace and run SETUP
The CMOS clock battery indicator shows the battery is dead. Replace the
battery and run Setup to reconfigure the system.
A-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
System CMOS checksum bad - Default configuration used
System CMOS has been corrupted or modified incorrectly, perhaps by an
application program that changes data stored in CMOS. The BIOS installed Default
Setup Values. If you do not want these values, enter Setup and enter your own
values. If the error persists, check the system battery or contact your dealer.
System timer error
The timer test failed. Requires repair of system board.
Real time clock error
Real-Time Clock fails BIOS hardware test. May require board repair.
Check date and time settings
BIOS found date or time out of range and reset the Real-Time Clock. May require
setting legal date (1991-2099).
Previous boot incomplete - Default configuration used
Previous POST did not complete successfully. POST loads default values and
offers to run Setup. If the failure was caused by incorrect values and they are
not corrected, the next boot will likely fail. On systems with control of wait
states, improper Setup settings can also terminate POST and cause this error on
the next boot. Run Setup and verify that the waitstate configuration is correct.
This error is cleared the next time the system is booted.
Memory Size found by POST differed from CMOS
Memory size found by POST differed from CMOS.
Diskette drive A error
Diskette drive B error
Drive A: or B: is present but fails the BIOS POST diskette tests. Check to see that
the drive is defined with the proper diskette type in Setup and that the diskette
drive is attached correctly.
Incorrect Drive A type - run SETUP
Type of floppy drive A: not correctly identified in Setup.
Incorrect Drive B type - run SETUP
Type of floppy drive B: not correctly identified in Setup.
A-2
Appendix A: BIOS POST Messages
System cache error - Cache disabled
RAM cache failed and BIOS disabled the cache. On older boards, check the
cache jumpers. You may have to replace the cache. See your dealer. A disabled
cache slows system performance considerably.
CPU ID:
CPU socket number for Multi-Processor error.
EISA CMOS not writeable
ServerBIOS2 test error: Cannot write to EISA CMOS.
DMA Test Failed
ServerBIOS2 test error: Cannot write to extended DMA (Direct Memory
Access) registers.
Software NMI Failed
ServerBIOS2 test error: Cannot generate software NMI (Non-Maskable
Interrupt).
Fail-Safe Timer NMI Failed
ServerBIOS2 test error: Fail-Safe Timer takes too long.
device Address Conflict
Address conflict for specified device.
Allocation Error for: device
Run ISA or EISA Configuration Utility to resolve resource conflict for the
specified device.
CD ROM Drive
CD ROM Drive identified.
Entering SETUP ...
Starting Setup program
Failing Bits: nnnn
The hex number nnnn is a map of the bits at the RAM address which failed
the memory test. Each 1 (one) in the map indicates a failed bit. See errors
230, 231, or 232 above for offset address of the failure in System,
Extended, or Shadow memory.
A-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Fixed Disk n
Fixed disk n (0-3) identified.
Invalid System Configuration Data
Problem with NVRAM (CMOS) data.
I/O device IRQ conflict
I/O device IRQ conflict error.
PS/2 Mouse Boot Summary Screen:
PS/2 Mouse installed.
nnnn kB Extended RAM Passed
Where nnnn is the amount of RAM in kilobytes successfully tested.
nnnn Cache SRAM Passed
Where nnnn is the amount of system cache in kilobytes successfully tested.
nnnn kB Shadow RAM Passed
Where nnnn is the amount of shadow RAM in kilobytes successfully
tested.
nnnn kB System RAM Passed
Where nnnn is the amount of system RAM in kilobytes successfully tested.
One or more I2O Block Storage Devices were excluded from the Setup
Boot Menu
There was not enough room in the IPL table to display all installed I2O blockstorage devices.
Operating system not found
Operating system cannot be located on either drive A: or drive C:. Enter Setup
and see if fixed disk and drive A: are properly identified.
Parity Check 1 nnnn
Parity error found in the system bus. BIOS attempts to locate the address and
display it on the screen. If it cannot locate the address, it displays ????. Parity is
a method for checking errors in binary data. A parity error indicates that some
data has been corrupted.
A-4
Appendix A: BIOS POST Messages
Parity Check 2 nnnn
Parity error found in the I/O bus. BIOS attempts to locate the address and display
it on the screen. If it cannot locate the address, it displays ????.
Press <F1> to resume, <F2> to Setup, <F3> for previous
Displayed after any recoverable error message. Press <F1> to start the boot
process or <F2> to enter Setup and change the settings. Press <F3> to display
the previous screen (usually an initialization error of an Option ROM, i.e., an
add-on card). Write down and follow the information shown on the screen.
Press <F2> to enter Setup
Optional message displayed during POST. Can be turned off in Setup.
PS/2 Mouse:
PS/2 mouse identified.
Run the I2O Configuration Utility
One or more unclaimed block storage devices have the Configuration Request bit
set in the LCT. Run an I2O Configuration Utility (e.g. the SAC utility).
System BIOS shadowed
System BIOS copied to shadow RAM.
UMB upper limit segment address: nnnn
Displays the address nnnn of the upper limit of Upper Memory Blocks,
indicating released segments of the BIOS which can be reclaimed by a virtual
memory manager.
Video BIOS shadowed
Video BIOS successfully copied to shadow RAM.
A-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Notes
A-6
Appendix B: BIOS POST Codes
Appendix B
BIOS POST Codes
This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST
codes are divided into two categories: recoverable and terminal.
Recoverable POST Errors
When a recoverable type of error occurs during POST, the BIOS will display
an POST code that describes the problem. BIOS may also issue one of the
following beep codes:
1 long and two short beeps - video configuration error
1 continuous long beep - no memory detected
Terminal POST Errors
If a terminal type of error occurs, BIOS will shut down the system. Before
doing so, BIOS will write the error to port 80h, attempt to initialize video and
write the error in the top left corner of the screen.
The following is a list of codes that may be written to port 80h.
POST Code
02h
03h
04h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Eh
0Fh
10h
11h
12h
13h
14h
16h
17h
Description
Verify Real Mode
Disable Non-Maskable Interrupt (NMI)
Get CPU type
Initialize system hardware
Disable shadow and execute code from the ROM.
Initialize chipset with initial POST values
Set IN POST flag
Initialize CPU registers
Enable CPU cache
Initialize caches to initial POST values
Initialize I/O component
Initialize the local bus IDE
Initialize Power Management
Load alternate registers with initial POST values
Restore CPU control word during warm boot
Initialize PCI Bus Mastering devices
Initialize keyboard controller
1-2-2-3 BIOS ROM checksum
Initialize cache before memory Auto size
B-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
POST Code
18h
1Ah
1Ch
20h
22h
24h
28h
29h
2Ah
2Ch
2Eh
2Fh
32h
33h
36h
38h
3Ah
3Ch
3Dh
41h
42h
45h
46h
47h
48h
49h
4Ah
4Bh
4Ch
4Eh
4Fh
50h
51h
52h
54h
55h
58h
59h
5Ah
5Bh
Description
8254 timer initialization
8237 DMA controller initialization
Reset Programmable Interrupt Controller
1-3-1-1 Test DRAM refresh
1-3-1-3 Test 8742 Keyboard Controller
Set ES segment register to 4 GB
Auto size DRAM
Initialize POST Memory Manager
Clear 512 kB base RAM
1-3-4-1 RAM failure on address line xxxx*
1-3-4-3 RAM failure on data bits xxxx* of low byte of
memory bus
Enable cache before system BIOS shadow
Test CPU bus-clock frequency
Initialize Phoenix Dispatch Manager
Warm start shut down
Shadow system BIOS ROM
Auto size cache
Advanced configuration of chipset registers
Load alternate registers with CMOS values
Initialize extended memory for RomPilot
Initialize interrupt vectors
POST device initialization
2-1-2-3 Check ROM copyright notice
Initialize I20 support
Check video configuration against CMOS
Initialize PCI bus and devices
Initialize all video adapters in system
QuietBoot start (optional)
Shadow video BIOS ROM
Display BIOS copyright notice
Initialize MultiBoot
Display CPU type and speed
Initialize EISA board
Test keyboard
Set key click if enabled
Enable USB devices
2-2-3-1 Test for unexpected interrupts
Initialize POST display service
Display prompt “Press F2 to enter SETUP”
Disable CPU cache
B-2
Appendix B: BIOS POST Codes
POST Code
5Ch
60h
62h
64h
66h
67h
68h
69h
6Ah
6Bh
6Ch
6Eh
70h
72h
76h
7Ch
7Dh
7Eh
80h
81h
82h
83h
84h
85h
86h
87h
88h
89h
8Ah
8Bh
8Ch
8Fh
90h
91h
92h
93h
95h
96h
97h
98h
Description
Test RAM between 512 and 640 kB
Test extended memory
Test extended memory address lines
Jump to UserPatch1
Configure advanced cache registers
Initialize Multi Processor APIC
Enable external and CPU caches
Setup System Management Mode (SMM) area
Display external L2 cache size
Load custom defaults (optional)
Display shadow-area message
Display possible high address for UMB recovery
Display error messages
Check for configuration errors
Check for keyboard errors
Set up hardware interrupt vectors
Initialize Intelligent System Monitoring
Initialize coprocessor if present
Disable onboard Super I/O ports and IRQs
Late POST device initialization
Detect and install external RS232 ports
Configure non-MCD IDE controllers
Detect and install external parallel ports
Initialize PC-compatible PnP ISA devices
Re-initialize onboard I/O ports.
Configure Motherboard Configurable Devices
(optional)
Initialize BIOS Data Area
Enable Non-Maskable Interrupts (NMIs)
Initialize Extended BIOS Data Area
Test and initialize PS/2 mouse
Initialize floppy controller
Determine number of ATA drives (optional)
Initialize hard-disk controllers
Initialize local-bus hard-disk controllers
Jump to UserPatch2
Build MPTABLE for multi-processor boards
Install CD ROM for boot
Clear huge ES segment register
Fix up Multi Processor table
1-2 Search for option ROMs. One long, two short
beeps on checksum failure
B-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
POST Code
99h
9Ah
9Ch
9Dh
9Eh
9Fh
A0h
A2h
A4h
A8h
AAh
ACh
AEh
B0h
B1h
B2h
B4h
B5h
B6h
B7h
B9h
BAh
BBh
BCh
BDh
BEh
BFh
C0h
C1h
C2h
C3h
C4h
C5h
C6h
C7h
C8h
C9h
CAh
CBh
CCh
Description
Check for SMART Drive (optional)
Shadow option ROMs
Set up Power Management
Initialize security engine (optional)
Enable hardware interrupts
Determine number of ATA and SCSI drives
Set time of day
Check key lock
Initialize typematic rate
Erase F2 prompt
Scan for F2 key stroke
Enter SETUP
Clear Boot flag
Check for errors
Inform RomPilot about the end of POST.
POST done - prepare to boot operating system
1 One short beep before boot
Terminate QuietBoot (optional)
Check password (optional)
Initialize ACPI BIOS
Prepare Boot
Initialize SMBIOS
Initialize PnP Option ROMs
Clear parity checkers
Display MultiBoot menu
Clear screen (optional)
Check virus and backup reminders
Try to boot with INT 19
Initialize POST Error Manager (PEM)
Initialize error logging
Initialize error display function
Initialize system error handler
PnPnd dual CMOS (optional)
Initialize note dock (optional)
Initialize note dock late
Force check (optional)
Extended checksum (optional)
Redirect Int 15h to enable remote keyboard
Redirect Int 13h to Memory Technologies
Devices such as ROM, RAM, PCMCIA, and
serial disk
Redirect Int 10h to enable remote serial video
B-4
Appendix B: BIOS POST Codes
POST Code
CDh
CEh
D2h
Description
Re-map I/O and memory for PCMCIA
Initialize digitizer and display message
Unknown interrupt
The following are for boot block in Flash ROM
POST Code
E0h
E1h
E2h
E3h
E4h
E5h
E6h
E7h
E8h
E9h
EAh
EBh
ECh
EDh
EEh
EFh
F0h
F1h
F2h
F3h
F4h
F5h
F6h
F7h
Description
Initialize the chipset
Initialize the bridge
Initialize the CPU
Initialize system timer
Initialize system I/O
Check force recovery boot
Checksum BIOS ROM
Go to BIOS
Set Huge Segment
Initialize Multi Processor
Initialize OEM special code
Initialize PIC and DMA
Initialize Memory type
Initialize Memory size
Shadow Boot Block
System memory test
Initialize interrupt vectors
Initialize Run Time Clock
Initialize video
Initialize System Management Manager
Output one beep
Clear Huge Segment
Boot to Mini DOS
Boot to Full DOS
* If the BIOS detects error 2C, 2E, or 30 (base 512K RAM error), it displays an additional
word-bitmap (xxxx) indicating the address line or bits that failed. For example, “2C
0002” means address line 1 (bit one set) has failed. “2E 1020" means data bits 12
and 5 (bits 12 and 5 set) have failed in the lower 16 bits. The BIOS also sends the
bitmap to the port-80 LED display. It first displays the checkpoint code, followed by
a delay, the high-order byte, another delay, and then the loworder byte of the error.
It repeats this sequence continuously.
B-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Notes
B-6
Appendix C: Software Installation
Appendix C
Software Installation
After all the hardware has been installed, you must first configure the
Adaptec Embedded Serial ATA RAID Driver before you install the
Windows operating system. The necessary drivers are all included on
the Supermicro bootable CDs that came packaged with your motherboard.
(For Adaptec's SCSI Host RAID Utility, please refer to the CDs that came
with your motherboard.)
C-1 Adaptec Embedded SATA RAID Controller Driver
Serial ATA (SATA)
Serial ATA (SATA) is a physical storage interface. It uses a single cable
with a minimum of four wires to create a point-to-point connection between
devices. SATA is a serial link which supports transfer rates from 150
MBps. Because the serial cables used in SATA are thinner than the traditional cables used in Parallel ATA (PATA), SATA systems have better airflow and can be installed in smaller chassis than Parallel ATA. In addition,
the cables used in PATA can only extend to 40cm long, while SATA cables
can extend up to one meter. Overall, SATA provides better functionality than
PATA.
Configuring BIOS settings for the SATA RAID Functions
1. Press the Del key during system bootup to enter the BIOS Setup Utility.
Note: If it is the first time to power on the system, we recommend that
you load the Optimized Default Settings. If you have already done so,
please skip to Step 3.
2. Use the arrow keys to select the "Exit" Menu. Once in the "Exit" Menu,
scroll down the menu to select the item "Load Optimized Default Settings"
and press the Enter key. Select OK to confirm the selection. Press the
Enter key to load the default settings to the BIOS.
3. Use the arrow keys to select the "Main" Menu in BIOS.
4. Scroll down to the item "SATA RAID Enable", select Enabled and
press Enter.
C-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
5. Tap the Esc key and scroll down to "Exit". Select "Save and Exit" from
the "Exit" menu. Press the Enter key to save the changes and exit the
BIOS.
6. Once you've exited the BIOS Utility, the system will re-boot.
7. During system startup, press the Ctrl and the A keys simultaneously
to run the Adaptec RAID Configuration Utility when prompted by the message: "Press <Ctrl><A> for Adaptec RAID Configuration Utility".
Adaptec Embedded SATA with HostRAID Controller
Driver
Adaptec's Embedded Serial ATA RAID with HostRAID controller adds
RAID functionality to the Serial ATA I/O controller by supporting RAID 0
(Striping) or RAID 1 (Mirroring) to enhance the industry's pioneer PCI-toe host controller products. RAID striping (RAID 0) can greatly improve
hard disk I/O performance because of its capability in striping data
across multiple drives. RAID mirroring (RAID 1) allows the data to be
simultaneously written to two drives, so critical data is always available
even if one hard disk fails.
Due to this built-in functionality, your Supermicro motherboard is specially
designed to keep pace with the increasing performance demands of
today's computer systems by improving disk I/O throughput and providing
data accessibility regardless of a single disk failure. By incorporating
Adaptec Embedded Serial ATA into the motherboard design, Supermicro
offers the user the benefits of SATA RAID without the high costs associated with RAID hardware.
Note: For Adaptec's RAID Driver Installation Instructions, please refer to
the Adaptec RAID Controller User's Guide: "Emb_SA_RAID_UG.pdf",
which is located in the CD that came with this motherboard. You can
also download a copy of Adaptec's User's Guide from our website at
www.supermicro.com.
C-2
Appendix C: Software Installation
Using the Adaptec RAID Configuration Utility (ARC)
The Adaptec RAID Configuration Utility is an embedded BIOS Utility, including:
*Array Configuration Utility: Use this utility when you want to create,
configure and manage arrays.
*Disk Utilities: Use this option to format or verify disks.
To run the Adaptec RAID Configuration Utility, you will need to enable the
RAID function in the system BIOS (refer to Chapter 7 for System BIOS
Configurations), and then press the Ctrl and A keys simultaneously
when prompted to do so during the system startup. (Refer to the previous page for detailed instructions.)
Note: To select an option, use the arrow keys to highlight the item and
then press the Enter key to select it. To return to the previous menu,
press the ESC key.
Using the Array Configuration Utility (ACU)
The Array Configuration Utility (ACU) enables you to create, manage, and
delete arrays from the controller’s BIOS, add and delete spare drives,
and initialize drives. During the system startup, press the Ctrl and A keys
simultaneously, and the main menu will appear.
C-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Managing Arrays
Select this option to view array properties and delete arrays. The following sections describe the operations Of "Managing Arrays".
To select this option, use the arrow keys and the Enter key to select
Managing Arrays from the main menu (as shown below).
C-4
Appendix C: Software Installation
Viewing Array Properties
To view the properties of an existing array:
1. At the BIOS prompt, press Ctrl+A.
2. From the ARC menu, select Array Configuration Utility (ACU).
3. From the ACU menu, select Manage Arrays (as shown on the previous screen.)
4. From the List of Arrays dialog box, select the array you want to view
and press Enter.
The Array Properties dialog box appears, showing detailed
information on the array. The physical disks associated with the array
are displayed here.
5. Press Esc to return to the previous menu.
Deleting Arrays
Warning: Back up the data on an array before you delete it to prevent
the loss of data. Deleted arrays cannot be restored.
1. Turn on your computer and press Ctrl+A when prompted to access
the ARC utility.
2. From the ARC main menu, select Array Configuration Utility
(ACU).
3. From the ACU menu, select Manage Arrays.
4. Select the array you wish to delete and press Delete.
5. In the Array Properties dialog box, select Delete and press
Enter. The following prompt is displayed:
Warning!! Deleting the array will render array unusable. Do you
want to delete the array?(Yes/No):
RAID 1 only - the following prompt is also displayed:
Deleting the partition will result in data loss! Do you also want to
delete the partition? (Yes/No):
6. Press Yes to delete the array or partition or No to return to the
previous menu.
7. Press Esc to return to the previous menu.
C-5
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Creating Arrays
Before creating arrays, make sure the disks for the array are connected
and installed in your system. Note that disks with no usable space, or
disks that are un-initialized are shown in gray and cannot be used. See
Initializing Disk Drives.
To create an array
1. Turn on your computer and press Ctrl+A when prompted to access
the ARC utility.
2. From the ARC menu, select Array Configuration Utility Main Menu
(ACU) (as shown on the first screen on page B-4).
3. From the ACU menu select Create Array.
4. Select the disks for the new array and press Insert (as shown on the
the screen below).
Note: To deselect any disk, highlight the disk and press Delete.
5. Press Enter when both disks for the new array are selected. The
Array Properties menu displays (as the shown on the screen on the next
page).
C-6
Appendix C: Software Installation
Assigning Array Properties
Once you've create a new array, you are ready to assign properties to
the array.
Caution: Once the array is created and its properties are assigned, you
cannot change the array properties using the ACU. You will need to use
the Adaptec Storage Manager - Browser Edition. (Refer to Adaptec's
User's Guide in the enclosed CD.)
To assign properties to the new array
1. In the Array Properties menu (as shown on the following screen),
select an array type and press Enter.
Note that only the available array types (RAID 0 and RAID 1) are displayed on the screen. (Using RAID 0 or RAID 1 requires two drives.)
2. Under the item "Arrays Label", type in a label and press Enter. The
label cannot be more than 15 characters.
3. For RAID 0, select the desired stripe size. (Available stripe sizes are
16, 32, and 64 KB - default. It is recommended that you do not change
the default setting.)
C-7
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
4. The item "Create RAID via" allows you to select between the different methods of creating RAID 0 and RAID 1.
The following table gives examples of when each is appropriate.
Raid Level
RAID 0
RAID 0
RAID 1
Create Via
No Init
Migrate
(*Note)
Build1
RAID 1
Clear
RAID 1
Quick
RAID 1
Init
When Appropriate
Creating a RAID 0 on new drives
Creating a RAID 0 from one new drive and
one drive with data you wish to preserve
Any time you wish to create a RAID 1, but especially if
you have data on one drive that you wish to preserve
Creating a RAID 1 on new drives, or when you want to
ensure that the array contains no data after creation.
Fastest way to create a RAID 1.
Appropriate when using new drives
5. When finished, press Done (as shown on the following screen).
Note: If you select Migrate for RAID 0, or Build for RAID 1, you will be
asked to select the source drive. The contents of the source drive will be
preserved. However, the data on the new drive will be lost.
C-8
Appendix C: Software Installation
Notes
1. Before adding a new drive to an array, back up any data contained on
the new drive. Otherwise, all data will be lost.
2. If you stop the build or clear process on a RAID 1 from ACU, you can
restart it by pressing Ctrl+R.
3. A RAID 1 created using the Quick Init option may return some data miscompares if you later run a consistency check. This is normal and is not a
cause for concern.
4. The ACU allows you to use drives of different sizes in a RAID. However,
during a build operation, only the smaller drive can be selected as the
source or first drive.
5. When migrating from single volume to RAID 0, migrating from a larger
drive to a smaller drive is allowed. However, the destination drive must be
at least half the capacity of the source drive.
6. Adaptec does not recommend that you migrate or build an array on
Windows dynamic disks (volumes), as it will result in data loss.
Warning: Do not interrupt the creation of RAID 0 using the Migrate option.
If you do, you will not be able to restart or to recover the data that was on
the source drive.
C-9
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Adding a Bootable Array
1. From the Main menu, select Manage Arrays.
2. From the list of arrays, select the array you want to make bootable and
press Ctrl+B.
3. Enter Y to create a bootable array when the following message is displayed: "This will make all other existing bootable array non-bootable. Do
you want to make this array bootable? (Yes/No):" A bootable array will
then be created. An asterisk will appear next to the bootable array.
Deleting a Bootable Array
To delete a bootable array
1. From the Main menu, select Manage Arrays.
2. From the List of Arrays, select the bootable array (*) you want to delete
and press Ctrl+B. (A bootable array is an array marked with an asterisk.)
3. Enter Y to delete a bootable array when the following message is displayed: "The array is already marked bootable. Do you want to make this
array as not bootable? (Yes/No):" The bootable array will then be deleted
and the asterisk will disappear.
Note: do not use the delete key to delete a bootable array.
C-10
Appendix C: Software Installation
Adding/Deleting Hotspares
Note: In order to rebuild a RAID (RAID 0 or RAID 1), you need to add a new
HDD as a hotspare.
1. Turn on your computer and press Ctrl+A as prompted to access the ARC
Utility.
2. From the ARC menu, select Array Configuration Utility (ACU).
3. From the ACU menu, select Add/Delete Hotspares.
4. Use the up and down arrow keys to highlight and select the disk you
want to designate as a hotspare, and press Insert, then press Enter.
5. Select Yes when the following prompt is displayed:
"Do you want to create spare?" (Yes/No?)
The spare you have selected will appear in the Select Drive Menu.
C-11
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Initializing Disk Drives
If an installed disk does not appear in the disk selection list for creating a
new array or if it appears grayed out, you may have to initialize it before
you can use it as part of an array. Drives attached to the controller must
be initialized before they can be used in an array.
Caution: Initializing a disk overwrites the partition table on the disk and
makes any data on the disk inaccessible. If the drive is used in an array,
you may not be able to use the array again.
Do not initialize a disk that is part of a boot array. To determine which
disks are associated with a particular array, please refer to Viewing
Array Properties.
To initialize drives:
1. Turn on your computer and press Ctrl+A when prompted to access
the ARC utility.
2. From the ARC menu, select Array Configuration Utility (ACU) (as
shown on the screen below).
3. Select Initialize Drives.
4. Use the up and down arrow keys to highlight the disk you wish to
initialize and press Insert (as shown on the following screen).
C-12
Appendix C: Software Installation
5. Repeat Step 4 so that both drives to be initialized are selected (as
shown on the following screen).
C-13
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
6. Press Enter.
7. Read the warning message as shown on the screen below.
8. Make sure that you have selected the correct disk drives to initialize.
If correct, type Y to continue.
Rebuilding Arrays
Note 1: Rebuilding applies to Fault Tolerant arrays (RAID 1) only.
If an array build process (or initialization) is interrupted or critical with
one member missing, you must perform a rebuild to optimized its functionality. For a critical array rebuild operation, the optimal drive is the source
drive.
Note 2: If no spare array exists and a hard disk drive fails, you need to
create a spare before you can rebuild an array.
To Rebuild an array:
1. From the Main Menu, select Manage Arrays. From the list of arrays,
select the array you want to rebuild.
2. Press Ctrl+R to rebuild.
C-14
Appendix C: Software Installation
Using the Disk Utilities
The Disk Utilities enable you to format or verify the media of your Serial
ATA hard disks.
To access the disk utilities:
1. Turn on your computer and press Ctrl+A when prompted to access
the ARC utility.
2. From the ARC menu, select Disk Utilities.
3. Select the desired disk and press Enter (as shown below.)
You can choose from the following options
1. Format Disk - Simulates a low-level format of the hard drive by writing
zeros to the entire disk. Serial ATA drives are low-level formatted at the
factory and do not need to be low-level formatted again.
Caution: Formatting destroys all data on the drive. Be sure to back up
your data before performing this operation.
2. Verify Disk Media - Scans the media of a disk drive for defects.
C-15
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
To Exit Adaptec RAID Configuration Utility
1. Once you have completed RAID array configurations, press ESC to
exit. The following screen will appear.
2. Press Yes to exit the Utility.
For more information regarding the Adaptec RAID Utility, please
refer to Adaptec's User's Guide in the CD included in your shipping package. You can also download a copy of Adaptec User's
Guide from our web site at: www. supermicro.com.
C-16
Appendix C: Software Installation
C-2 Installing Intel's ICH5R Driver by Adaptec and
Windows OS
1. Insert Supermicro's bootable CD that came with the package into the
CD Drive during the system reboot. The "Super Micro Driver Diskette
Maker" screen will appear.
2. Choose "Intel ICH5R Driver by 3rd Party (Adaptec)" from the items
listed and press Enter.
3. From the next screen displayed, choose the OS driver you want to
install and press Enter.
4. Insert a formatted diskette into drive A: and press Enter as prompted.
5. Exit the program after the process is completed. Then, reboot the
system.
6. Insert Microsoft Windows OS Setup CD in the CD Driver. The system
will boot up from the CD.
7. Press the F6 key when the message "Press F6 if you need to install a
third party SCSI or RAID driver" is displayed.
8. When the Windows OS Setup screen appears, press S to specify
additional device(s).
9. Insert the driver diskette labelled "Adaptec Embedded Serial ATA Raid
Controller Driver" into your floppy drive and press the Enter key.
10. Choose Adaptec Embedded Host Serial ATA Raid Controller
from the list indicated in the Windows OS Setup Screen and press the
Enter key.
11. Press the Enter key to continue the installation process. (If you need
to specify any additional devices to be installed, do so at this time.) Once
all devices are specified, press the Enter key to continue with the installation.
12. From the Windows OS Setup screen, press the Enter key. The OS
setup routine will automatically load all device files and continue the Windows OS installation.
13. After the Windows OS installation has completed, the system will
automatically reboot.
C-17
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
C-3 Installing Other Software Programs and Drivers
Installing Other Drivers
After you've installed the Windows Operating System, a screen (as
shown in Figure C-1) will appear. You are now ready to install additional
software programs and drivers. To install these software programs and
drivers, click the icons to the right of these items.
Figure C-1. Driver/Tool Installation Display Screen
Click the icons showing a hand writing on paper to view the readme files
for each item. Click the computer icons to the right of these items to install
each item (from top to the bottom) one at a time. After installing each
item, you must re-boot the system before moving on to the next
item on the list. You should install everything here except for the SUPER
Doctor utility, Intel LDCM and the LAN/SCSI driver diskettes, which are
optional. The bottom icon with a CD on it allows you to view the entire
contents of the CD.
Note: Please refer to the Adaptec User's Guide (included in the CD) for
installing the Adaptec SATA RAID Controller Driver. You can also download
a copy of the guide from our website.
C-18
Appendix C: Software Installation
Supero Doctor III
The Supero Doctor III program is a web-based management tool that
offers both remote and local management tools. The local management
application is called SD III Client. The Supero Doctor III program included
on the CDROM that came with your motherboard allows you to monitor
the environment and operations of your system. Supero Doctor III displays crucial system information such as CPU temperature, system voltages and fan status. See Figures C-2 and C-3 for examples of the
Supero Doctor III interface.
Figure C-2. Supero Doctor III: Health Information Display
C-19
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Figure C-3. Supero Doctor III: Remote Control Display
Note: SD III Software Revision 1.0 can be downloaded from our Web site
at: ftp://ftp.supermicro.com/utility/Supero_Doctor_III/. You can also
download the SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we recommend using Supero
Doctor II.
C-20
Appendix D: System Specifications
Appendix D
System Specifications
Processors
Single or dual Intel ® Xeon EM64T 604-pin processors at a front side
(system) bus speed of 800 MHz
Note: Please refer to the support section of our web site for a complete listing of supported
processors. (http://www.supermicro.com/support/)
Chipset
Intel E7520 chipset
BIOS
4 Mb Phoenix ® Flash ROM
Memory Capacity
6014H-i2 (X6DHR-iG2): Eight 240-pin DIMM sockets supporting up to 16
GB of low-profile, registered ECC DDR2-400 SDRAM
6014H-i/6014H-Xi (X6DHR-iG/X6DHR-XiG): Eight 184-pin DIMM sockets
supporting up to 16 GB of low-profile, registered ECC DDR333 SDRAM or
32GB of low-profile, registered ECC DDR266 SDRAM
Note: Interleaved memory - requires memory to be installed two at a time. See the memory section
in Chapter 5 for details.
Peripheral Drive Bays
One (1) 3.5" slim floppy drive
One (1) slim CD-ROM drive
Three (3) 3.5 x 1" drive bays (for IDE drives)
Expansion Slots
6014H-i2: one standard PCI-X card of any speed and one low-profile PCIX card (100 or 66 MHz only) or (with optional riser cards sold
separately) two x8 PCI-Express cards.
6014H-i: one standard PCI-X card and one low-profile PCI-X card of any
speed or (with optional riser cards sold separately) one x8 PCI-Express
and one x4 PCI-Express card.
6014H-Xi: two (one standard, one low-profile) PCI-X cards of any speed.
D-1
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Motherboard
6014H-i2: X6DHR-iG2 (Extended ATX form factor)
6014H-i: X6DHR-iG (Extended ATX form factor)
6014H-Xi: X6DHR-XiG (Extended ATX form factor)
Dimensions: 12 x 13 in (305 x 330 mm)
Chassis
Model: SC812i-420 Form Factor: 1U rackmount
Dimensions: (WxHxD) 16.7 x 1.7 x 25.6 in. (424 x 44 x 650 mm)
Weight
Net (Bare Bone): 38 lbs. (17.3 kg.)
System Cooling
Two (2) 10-cm blower fans (fan speed controlled by BIOS setting)
System Input Requirements
AC Input Voltage: 100-240V AC auto-range
Rated Input Current: 7A (max.)
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: Model# SP423-1S, Part# PWS-0053-20
(420W AC w/PFC)
Rated Output Voltages: +3.3V (20A), +5V (30A), +12V ALL (32A), +5Vsb
(2.0A)
BTU Rating
2200 BTUs/hr (for rated output power of 420W)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
D-2
Appendix D: System Specifications
Regulatory Compliance
Electromagnetic Emissions:
FCC Class B, EN 55022 Class B, EN 61000-3-2 & EN 61000-3-3,
CISPR 22 Class B
Electromagnetic Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada),
TUV Certified (Germany), CE Marking (Europe)
D-3
SUPERSERVER 6014H-i2/6014H-i/6014H-Xi Manual
Notes
D-4

advertisement

Related manuals

Download PDF

advertisement