Concentrated performance Programmable relay, Ethernet relay, WI-FI relay, GSM/GPRS Relay www.rievtech.com

Concentrated performance Programmable relay, Ethernet relay, WI-FI relay, GSM/GPRS Relay www.rievtech.com
Programmable relay, Ethernet relay,
WI-FI relay, GSM/GPRS Relay
Concentrated performance
Update:2015.12
Ver. 1.1
www.rievtech.com
Contents
Presentation of RIEVTECH
P.3
xLogic programmable relay overview
P.4
The range of xLogic programmable relay
P.5
x-Messenger GSM/GPRS/Ethernet/ WIFI relay overview
P.6
The range of x-Messenger GSM/GPRS/Ethernet/ WIFI relay
P.7
Accessories of xLogic and x-Messenger
P.8
Communication solution
P.9
Software
P.11
Application
P.12
Installation Dimensions
P.15
Model Selection
P.17
xLogic and x-Messenger Wiring
P.20
xLogic and x-Messenger Technical Data
P.22
Tel:025-52895099
订购:
[email protected]
2
Presentation of
RIEVTECH
RIEVTECH(R: reliable, I: innovative, E: easy, V: value-added) ,EEC(Easy Electronic Co.,Ltd)a sister company of EEC ,
would be dedicated into global marketing and sales of all products developed and made by EEC under the trademark of
"RIEVTECH" since its establishment.
EEC(Easy Electronic Co.,Ltd) is a leading manufacturer of automation Micro-control components, such as Micro PLC,
super relay , super power, multifunction timer, counter etc, has been fast growing since its foundation, EEC also adapts
its products to meet your specific application requirements. These products are ideal for applications like heating/air
conditioning, access control, heat pumps, water and air treatment, waste treatment, lifting and handling, medical
equipment and pump management.
We invest heavily in the areas of quality, R&D and new product innovation, EEC customers include manufacturers of
machines and industrial equipment, OEMs, distributors, panel-builders, installers, system integrators.
Recognized across the industry for its responsive, flexible services; EEC can customize its products to match the
specifications of OEMs, equipment manufacturers, distributors and integrators. We are driven by a culture of customer
satisfaction. EEC works closely with customers to identify their exact technical and budget requirements to develop the
suitable solution for their application.
Some of the company’s most popular products can be found in the our SuperRelay series. These are the latest in a
generation of powerful and flexible Micro-PLCs. The manufacturing process ensures they can be offered at affordable
prices, and they are suitable for replacing such devices as Mini-PLCs and multiple components, like timers, counters and
relays. Today, EEC xLogic SuperRelay products are considered by many to be cost-effective alternatives to the more
expensive options on the market.
EEC Electronics also has the x-Messenger GSM/GPRS PLC, a telemetry solution that calls on a broad range of CPUs,
software and accessories – all designed for GSM and GPRS wireless systems, which are in turn used for tasks such as
diagnostics and data logging. The recent introduction of our Ethernet and Wi-Fi based low cost programmable logic
controls underlines our companys’ commitment to market changes and product development!
As a innovative and fast-growing maker, EEC's strategy is founded on continuous innovation. We spend 8%-10% of our
annual revenue on research and development. To cater for the stringent demands of industrial markets, EEC has also
established a policy of continuous improvement through strict quality management.
EEC incorporates eco-design into its processes and ensures that we comply with environmental directives, including the
RoHS regulations.
www.rievtech.com
3
xLogic. overview
Rievtech Program Relay
xLogic, overview
The xLogic program relay includes economic and advanced models, incorporating a good mix of digital &
analogue IO , Integrated High Speed inputs and PWM output, counters, timers,real time clock and time switch functi
ons. Available in 120V/240VAC or 12V/24VDC versions;Easy to configure with drag-and-drop function blocks usi
ng FREE xLogicSoft software.With HMI range offers 4-line detachable LCD display and keypad for modifying
parameters or display and control whilst program is running.
+
+
Timers
Control Relays
+ More
+
Counters
Temperature Controllers
Power Supply Terminal
Input Terminals
Program port(RS232 or
USB program cable is
LCD
4x16
required.)
characters
display
Expansion port(can be
connected
6 keypads:
with
expansions and RS485
Up,Down,Left,Right,ESC,OK
communication module.)
Output terminals
Up/Down
Kinds of
Astronomical
Analog
PI
counter
Timer function
Clock
Math
Controller
To tackle simpler applications that still require a powerful logic controller.
Rievtech offers various range CPU and extensions(6 to 274I/Os) selection with a range of accessories to cover
a lots of control requirements.
4
www.rievtech.com
The Range of
xLogic
Rievtech Program Relay
xLogic Hightlight













Extremely large program capacity:up to 1024 functions possible.(64 functions for economic series)
Flexibly expandable up to 140DI,136DO,70AI,and 32AO.
Display of message texts,actual and set-point values and direct modification of the values on the display(not on pure
variants).
Integrated data retentivity-ensures backup of the current values in the event of a power failure.(not on pure variants)
Bool function,multiple timers,counters,PWM,PI controller,Ramp.Analog math supported.
Modbus RTU/ASCII/TCP protocol supported.(MODBUS TCP is only for Ethernet CPU)
It’s optional for xLogic to act as salve or master in certain Modbus communication network.
Backup at Real Time Clock(RTC) at 25 ℃: 20days.
Communicate with third party device which supports Modbus network.
Data-logging:Data from the production process can be saves in SD card of the external accessory called
ELC-MEMORY to either read it with a PC or evaluate it from the SD card at the workstation.
70 ready-to use functions integrated-no additional devices such as operating hours counter required. (34 for
economic range)
Powerful communication capability(1RS232 port,1 RS485 port and 1 expansion port)
Password protection, the “disable read program” function protect program of OEM customer better.
Built-in Ethernet series
Micro series(Non-expandable)
ELC-6(no display)
4DI/2DO
PR-12E-CAP(no
display)
Expandable Series
PR-18
8DI/4DO
ELC-12-N
8DI/4DO
PR-12-HMI
8DI/4DO
Extension modules
PR-24
14DI/10DO
PR-E-16
8DI/8DO
5
V(0...10V),
mA(0/4...20mA), PT100
Special signal extension
RS485 Communication
module
www.rievtech.com
x-Messenger. overview
Rievtech GSM/GPRS Controller
x-Messenger overview
Incorporates a wide range of CPUs, expansions, various accessories and software, specially designed for GSM/
GPRS wireless systems being used for remote measurements, data logging, control, diagnostics and object via
short text messages (SMS) or CLIP calls. Configurable messages sending from device with static (text) or
dynamic (text) and measured values content are a convenient way of passing important information to the
monitoring center, or directly tothe defined phone numbers. SMS messages sending or Call out can be
triggered by change of binary input state, reaching alarm thresholds, marker state change, counters and clocks.
In particular, x-Messenger shall possess industrial design, practical set of I/O resources& easy to use configuration
software tools. Multiple optional analog signals (0..10V DC) (0…20mA) ,(PT100) inputs built-in the module ,
make it possible to have direct connection of sensors, which lowers the cost of building system. Hence, it can
directly work with humidity sensors,water level sensor, pressure transducers, flow sensors, smoke, gas, motion,
shock and noise detectors, etc.
Inputs terminal
Power Supply Terminal
Expansion port or
Program port(RS232 or
USB cable is required)
RS485 module
connection port
Keypad for modify
parameters
LCD 4x16 characters
display ( SIM card slot
is under LCD panel)
Wifi Antenna SMA
connector(Only WIFI
CPU has this connector)
GSM Antenna SMA connector
(3 meters antenna in package)
Output Terminals
LAN interface(Only Ethernet CPU
or WIFI cpu has such connector)
Rievtech offers various range x-Messenger CPU and extensions selection with a range of accessories to cover
a lots of control and telemetry requirements with GSM/GPRS/WIFI.
6
www.rievtech.com
The Range of x-Messenger
Rievtech GSM/GPRS controller
x-Messenger hightlight














Integral GSM 850/900/1800/1900 modem
GPRS, SMS ,Email and CLIP support
Parameters in the program changing by means of SMS via cell phone
RTC, Timers and Counters, High speed input
Time-based and event-based SMS, Call-IN, Call-Out, Ring, voice
IO status ,alarming message includes counters, analog values can be directly sent to Users
Max. 64 different short messages and voice alarms
Backup at Real Time Clock (RTC) at 25 °C:100 hours
4-lines, 16-character per line, backlight display& keypad optional
Standard Modbus RTU/ASCII/TCP communication protocol supported
1 RS232,1 RS485, 1Ethernet interface optional
It’s optional for x-Messenger to act as slave or master in certain Modbus communication network.
1 Audio output interface optional
WIFI connection optional(WIFI CPU)
Standard model
Built-in Ethernet(with“-N”)
EXM-12
8DI/4DO
Built-in Wifi function(With “-Wifi”)
EXM-12-WIFI
8DI/4DO
Built-in voice function(with“-V”)
EXM-12-N
8DI/4DO
EXM-12-VN
8DI/4DO
EXM expansion modules
V(0...10V),
mA(0/4...20mA), PT100
special signal extension
EXM-E-8
4DI/4DO
7
RS485 communication
module
Accessories of xLogic and x-Messenger
Rievtech program relay and controllers
Accessories of xlogic and x-Messenger
With a whole accessories range: switch power supply, program copier, data-logger, RTC backup battery, 4.3touch
screen(only can display the contents of bilt-in LCD), and communication cables(RS232,USB,RS485 types), simple and
small control requirement can be easily developed with xlogic program relay or x-Messenger GSM controller.
USB Program
RS232
cable
program
cable
Switch power supply
Data-logger
5V/12V/24V
xLogic
RTC backup battery
4.3 inch screen(
Same role as the LCD)
Program copier
x-Messenger
Connection cable
between EXM CPU and
extension(3 meter long)
Ex-flat cable between
PRO-RS485(Program
PR series CPU and
port to RS485 BUS)
extension(1.5
meter
long)
8
www.rievtech.com
Communication solution
Communication selection
LCD need be installed separately with CPU

RS232 program cable
CPU installed in cabinet, operation panel in
xLogic
the front door of cabinet.

Viewing setpoints and alarming message on
a touch panel less than 15 m away.

RS232 program cable
Two screen display, LCD built-in and touch
x-Messenger
panel remotely.

No additional configure software Simple
directly make the connection with RS232
cable then it will works.
Modbus protocol via RS232/RS485/Ethernet supported makes it almost any HMI/touch panel can communicate with xlogic/x-messenger.

Touch
screen
works
as
master,
all
从站 1
xLogic/x-Messenger work as slaves.

Text
panel
works
as
slave,
the
PRO-RS485 cable
xLogic/x-Messenger works as master

All the xlogics and x-Messenger
从站 2
Or RS485 module
RS232 communication cable
programming port can be used as RS232
从站 3
connection or RS485 connection with
different accessories .
PR-E series extension can be linked up to 1km away from CPU.

CAN BUS connection between PE-E
series expansion and expandable CPU,
Max. Distance 1km
can meet the dispersal IO control
requirement.

Twisted cable
Extension module works like remote
CAN IO unit

Total 16 expansion can be connected to
CPU up to 274 IOs.
CPU
Extension 1
Extension 2
Extension 16
It’s option to make the xlogic or x-Messenger works as master or slave, each com port works separately.

We can use xLogic and x-Messenger
connection through RS485, then SMS
function will be available on xLogic
RS232/RS485
system and total IO numbers will be
Slav
e
added.

Programming port/RS232 works as slave
communicate with HMI, then RS485 port
works as master to communicate with
Master
Master
Slave 1
other devices: inverter, counter, sensors,
Slave 2
Slave 3
meters.
9
www.rievtech.com
Communication solution
GSM, GPRS, Ethernet, Wifi communication
Alarming and Control by GSM

Alarming message or report data
(includes IO status, sensor values, counter
values , machine parameters). Control
relays, doors, motors with cellphone.

Send SMS to change the setpoints or
receiver numbers with fixed format SMS.

Remote station x-Messenger can send
SMS includes kinds of parameters to local
x-Messenger.
Modbus is also applied to x-Messenger, so other modbus devices connected to x-Messenger will have SMS,GPRS capacity.

x-Messenger can read other modbus
device status and values for display or
Sensor
Switch
use in its program or transfer to data
center

You can make a call to trigger a bit
status in x-Messenger, for example
make a call to open door.

Router
Application server
Alarming messages or data report also
can be sent out with Email.
RS485
Slave1
Slave 2
Slave 32
Ethernet communication: built-in LAN port, standard TCP/IP protocol

Built-in LAN port, ethernet module
configure software shows all the
on-line units

Ethernet module can be configured as
TCP server, or TCP client.

4 Ethernet units can communicate each
other, one works as tcp server, other 3
work as tcp client.

Communication with other device
(touch screen , PC SCADA etc) which
support MODBUS TCP.
The WIFI unit can connect to Ethernet network without any cable

Wireless Parameters Support 802.11b/g
/n wireless standards

WIFI unit can be configured work as
AP or STA mode

Wireless upload/download program

xLogicApp(Andriod) can directly
control wifi unit through standard
MODBUS TCP protocol.
10
www.rievtech.com
Software
xLogicsoft(ELC and PR series PLC program software)& eSmsConfig(EXM series controller programming software)
Free
xLogicsoft&eSmsConfig are both can be downloaded from our website (www.rievtech.com)
Easy to use

Quick, simple and intuitive
programming requires no specialist
knowledge

Self-teaching made easier thanks to a
user-friendly on-line help guide

A simulation mode that consistently
represents controller operation
Powerful
 70 kinds of function
blocks:counting,timing,comparison,dis
play,logic etc can be connected in a
program can be up to 512 blocks in
Maximum.

The interface supports 7
languages:English,Russian,
EasySCADA
Czech,German,French,Spanish,Chinese
Free Again
EasySCADA package can be downloaded from our website (www.rievtech.com) as well
Complete functions
including basic shape drawing,trend
picture display,meter,historical data
collection
Powerful Communication
easyMonitor provides drives for
communication with PLCs projects of all
PR,ELC and EXM series CPU via RS232,
RS485,Ethernet/GPRS. Available protocol is
MODBUS RTU/TCP.
Multiple Resources
Easy Monitor provides abundant resources.
The picture library of easy monitor includes
indicator light, button, tank, pipe, bars. In add
ition, many pictures are provided with
animation properties and can be used to design
vivid animation.
It also allows for user-defined picture library
and inserting pictures from Windows.
11
www.rievtech.com
Application
Where are they found?
Building Equipment
Access Control
Automatic Barriers
Opening Control for doors
Control opening and
closing of doors and
other associated
security devices for
Restricting access;
synchronization
between the various
doors
Control barriers with
automatic detection of
vehicles.
Function for selecting
opening times/days
HVAC
Air treatment plant
Heat Pump
Management of various
parameters such as
heating, cooling,
Fluid temperatures,
operation,calendar-based
function,alarm
management, etc
Maintaining force air
at the correct
temperature.
PI controller block is
available in program
Building Automation
Light Control
Solar water heating
Managing flashing
on LED lights,
illuminated signs.
Actions(ON/OFF)
based on Weekly
timer,year timer,
astronomical
clock.
Automation of
operation and
heating regulation,
remote management
of the installation
12
www.rievtech.com
Application
Infrastructure and Energy
Fluid Management
Swimming pools, fountains, spas
Irrigation/Sprinklers
Managing circulation
pumps,
monitoring levels,
temperature
and conductivity of
the water
Irrigation control
based on
temperature,
humidity, and
day/night cycle
Energy Saving
Wind strength and direction measurement
Hotel power saving
The xlogic has been
applied to a variety of
hotels for energy
saving in Europe.
Switch off power
when occupy sensor
checked no person in
room.
Customer is using the
xLogic to monitor
wind speed and
direction for off-shore
wind farms around the
UK coast.
Industry Equipment
Steel pipe process equipment
Hoisting machine
xLogic is already used
on the equipment
which process the steel
pipe. To measure the
steel pipe length and
make it with a angle or
cut off it.
The xlogic has been
used for controlling
the electromagnetism
derrick in China
13
www.rievtech.com
Application
GSM/GPRS Controller application
Home security and
Fluid ,Temperature monitoring and control
Industry equipment
Remote monitor the
fluid(With SMS message
report or alarming).
Control the valve on/off
remotely by SMS.
Home security, user is
allowed to edit kinds of
SMS to indicator the
status of the sensor
installed at home.
Temperature
monitoring and control
in Data Central room.
Equipment status and
production information
can be report to
management person or
System on PC.
Collection sensor datas through GPRS
Multiple Signals( Digital, Analog, PT100, Relay)
Control light, Heat, Cooling, Sprinkler,
automatic door by SMS. Get alarming
message or collection datas by SMS as well
Collect data from kinds of sensor through GPRS,
Ethernet remotely. It’s a good combination of
DTU and PLC.
Other typical applications:
Medical,Solar, Agricultural Equipment, Transportation, Hoisting,Handling...
14
www.rievtech.com
Installation Dimensions
PR-6 CPU
And EXM-E
extension
游泳池,喷泉,温泉
灌溉/喷头
PR-12-CAP(no
HMI) CPU
加热泵
酒店节能
风力,风向检测
PR-12-HMI
CPU
PR-18 CPU
钢管折弯设备
起重设备控制
PR-E series
extension
15
www.rievtech.com
Installation Dimensions
PR-24 series
家庭安全
CPU
EXM series
CPU
And ELC-12-N
Ethernet CPU
通过 GPRS 网络远程采集各种传感器信息
ELC-AS/AL
Power supply
Data-logger
Program-Copier
RTC-Battery
RS232 Program cable(2M)
USB Program cable (2M)
PRO-RS485 cable(2M)
16
Model Selection
xLogic
Model
Power
PR-6AC-R
AC 110-240V
4 AC
2(10A Rly)
---
---
N
PR-6DC-DA-R
DC12-24V
4 DC
2(10A Rly)
---
---
N
PR-12AC-R-E-CAP
AC 110-240V
8 AC
4(10A Rly)
---
---
N
PR-12DC-DA-R-E-CAP
DC12-24V
8 DC
4(10A Rly)
4 (0...10V)
---
N
PR-12AC-R-HMI
AC 110-240V
8 AC
4(10A Rly)
---
---
Y
PR-12DC-DA-R-HMI
DC12-24V
8 DC
4(10A Rly)
4 (0...10V)
---
Y
4HSI(60KHZ)
PR-12DC-DA-TN-HMI
DC12-24V
8 DC
4(0.3A PNP)
4 (0...10V)
---
Y
4HSI(60KHZ)
PR-18AC-R-HMI
AC 110-240V
12 AC
6(10A Rly)
---
---
Y
PR-18DC-DA-R-HMI
DC12-24V
12 DC
6(10A Rly)
6 (0...10V)
---
Y
4HSI(60KHZ)
PR-18DC-DA-RT-HMI
DC12-24V
12 DC
4R(10A)+2T(0.3A)
6 (0...10V)
---
Y
4HSI(60KHZ)
PR-24AC-R-HMI
AC 110-240V
14 AC
10(10A Rly)
---
Y
4HSI(60KHZ)
PR-24DC-DA-R-HMI
DC12-24V
14 DC
10(10A Rly)
6 (0...10V)
---
Y
4HSI(60KHZ)
PR-24DC-DAI-RTA-HMI
DC12-24V
12 DC
6R+2T+2Analog
2I+4V
1 V/1 I
Y
V=0-10V;I=0/4..20mA;
Eth
CPU
ELC-12AC-R-N-HMI
AC 110-240V
8 AC
4(10A Rly)
---
Y
Eth=Ethernet
ELC-12DC-DA-R-N-HMI
DC12-24V
8 DC
4(10A Rly)
---
Y
2HSI(60KHZ)
Expansions for PR-18 CPU
xLogic Program Relay
PR-E-16AC-R
AC 110-240V
8 AC
8 Rly
---
---
Q1-Q4(3A)+Q5-Q8(10A)
PR-E-16DC-DA-R
DC12-24V
8 DC
8 Rly
4 (0...10V)
---
---
Q1-Q4(3A)+Q5-Q8(10A)
PR-E-AI-I
DC12-24V
---
---
4(0/4...20mA)
---
---
Resolution(0.02mA)
PR-E-PT100
DC12-24V
---
---
3 PT100
---
---
Range:(-50--200℃)
Accessories
Expandable CPU
Non-expandable CPU
Type
Digital
Input
Digital Output
Analog
Input
Analog
Output
---
--4 (0...10V)
---
HMI
Comment(HSI=High
speed input)
4HSI
Resolution:0.3℃
PR-E-AQ-VI
DC12-24V
---
---
---
2(0...10V)
---
/2(0...20mA)
---
---
---
---
Resolution(0.02V)/
Resolution(0.02mA)
PR-RS485
DC12-24V
---
With Isolated RS485 module
ELC-USB
USB download cable
ELC-RS232
RS232 download cable, also can be used as the RS232 connection cable between PLC and other device with RS232 interface
ELC-43TS
4.3touch screen, it plays the same role as the LC, just install separately of PLC.
ELC-Copier
Program copier, copy program between same model PLCs
ELC-MEMORY
Data-logger,,save IO,Analog value,parameters into .txt file in SD card.
ELC-BATTERY
RTC backup battery,
PRO-RS485
Program port convert RS485 port
Naming Rule:
CPU:1.Series Name:ELC and PR series
Extension:1.Series name:PR series
2.Total points of IO:6,12,18,22
2.E, expansion
3.Power:DC(12/24V) AC(110-240V)
3.Total points of IO:6,12,18,22
4.Input type:DA,digital&analog
4.Power:DC(12/24V) AC(110-240V)
5.Output type: R:relay; TN:PNP type transistor
5.Input type:DA,digital&analog
6.HMI:-HMI,with display,no/-CAP :without display
6.Output type: R:Relay; TN:PNP type transistor
Note:-N:with Ethernet module
Note:AI-I:0/4..20mA Input; AQ-I:0..20mA output
AQ-VI:0...10V/ 0..20mA output
17
PT100:PT100 input
www.rievtech.com
Model Selection
x-Messenger
x-Messenger GSM/GPRS Controller
standard
Type
Model
Power
Digital
Input
Digital
Output
Analog Input
EXM-8AC-R-HMI
AC 110-240V
6 AC
2(10A Rly)
EXM-12DC-DA-R-HMI
DC12-24V
8 DC
4(10A Rly)
EXM-12DC-DAI-R-HMI
DC12-24V
6 DC
4(10A Rly)
Analog
Output
---
HMI
Comment
---
N
Support GSM,GPRS,EMAIL
4(0...10V)
---
N
Support GSM,GPRS,EMAIL
2(0...10V)
---
N
Support GSM,GPRS,EMAIL)
---
N
Support GSM,GPRS,EMAIL
---
Y
With
+2(0..20mA)
EXM-8DC-PT100-R-HMI
DC12-24V
2 DC
4(10A Rly)
2 PT100+
Accessories
Extension for all EXM
series CPU
With Wifi
CPU
With Ethernet
CPU
2(0...10V)
EXM-12DC-DA-R-N-HMI
DC12-24V
8 DC
4(10A Rly)
4(0...10V)
GSM,GPRS,EMAIL,Ethernet
EXM-12DC-DA-R-VN-HMI
DC12-24V
8 DC
4(10A Rly)
4(0...10V)
---
Y
Support GSM,GPRS,EMAIL,
Ethernet,voice
EXM-12DC-DA-RT-WIFI-
DC12-24V
8 DC
HMI
2(10A Rly)+2
4(0...10V)
---
Y
No GSM,GPRS,EMAIL
4(0...10V)
---
Y
Support GSM,GPRS,EMAIL
---
---
Q1-Q2(3A)+Q3-Q4(10A)
4(0...10V)
---
---
Q1-Q2(3A)+Q3-Q4(10A)
(0.3A Trn)
EXM-12DC-DA-RT-GWIFI-
DC12-24V
8 DC
HMI
2(10A Rly)+2
(0.3A Trn)
EXM-E-8AC-R
AC 110-240V
4 AC
4 Rly
---
EXM-E-8DC-DA-R
DC12-24V
8 DC
8 Rly
EXM-E-AI-I
DC12-24V
---
---
4(0/4...20mA)
---
---
Resolution(0.02mA)
EXM-E-PT100
DC12-24V
---
---
3 PT100
---
---
Range:(-50--200℃)
Resolution:0.3℃
EXM-E-AQ-V
DC12-24V
---
---
---
2(0...10V)
---
Resolution(0.02V)
EXM-E-AQ-I
DC12-24V
---
---
---
2(0...20mA)
---
Resolution(0.02mA)
EXM-E-RS485
DC12-24V
---
---
---
---
---
With Isolated RS485 module
ELC-USB
USB download cable
ELC-RS232
RS232 download cable, also can be used as the RS232 connection cable between PLC and other device with RS232 interface
ELC-43TS
4.3touch screen, it plays the same role as the LC, just install separately of PLC.
ELC-Copier
Program copier, copy program between same model PLCs
ELC-MEMORY
Data-logger,,save IO,Analog value,parameters into .txt file in SD card.
ELC-BATTERY
RTC backup battery,
PRO-RS485
Program port convert RS485 port
EXM-CB-B
Connection cable between EXM CPU and Extension 3meters long
Naming rule:
CPU:1.Series name:EXM series
Extension:1.Series Name:PR series
2.Total IOs:8,12
2.E, expansion
3.Power:DC(12/24V) AC(110-240V)
3.Total IOs:6,12,18,26
4.Input type:DA,digital and analog
4.Power:DC(12/24V) AC(110-240V)
5.Output type: R:Relay; T:PNP type transistor
5.Input type:DA,digital and analog
6.Special function:-N:built-in Ethernet;-VN: With
6.Output type: R:Relay; TN:PNP type transistor
Ethernet and voice; WIFI; with WIFI function
Note:AI-I:AI-I:0/4..20mA Input; AQ-I:0..20mA output
7.-HMI:with display panel
AQ-V:0...10V output
18
PT100:PT100 input
www.rievtech.com
Model Selection
xLogic switch power supply
Model
ELC-05AS
ELC-12AS
ELC-24AS
ELC-05AL
ELC-12AL
ELC-24AL
Ouput voltage
DC 5V
DC 12 V
DC 24 V
DC 5V
DC 12V
DC 24V
Output Current
6A
3A
1.5A
10 A
Dimension
(LxWxH)
71*106*65
Installation
6A
3A
126*106*65
35mm standard DIN rail, or wall-mounting
Input Voltage
110--240VAC/140--340VDC
Allowance range
85--265VAC/140--340VDC
Input Frequency
43-67 Hz
Output Voltage
Stability
≤ 0.5%
Ripple
≤ 150 mVp-p
Temperature
-25℃--70℃
Insulation and
breakdown
> 1.5KV
Efficiency
>75%
1. Remote Control:
Close switchK1,output voltage,
Open switchK1,no voltage output。
(Short circuit block connected in default)
2. Using UPS function:
(If the battery voltage is over +24V, you need
to adjust potentiometer(V) to make it over
battery voltage, the adjustable voltage is not
exceed 26.5V.
19
www.rievtech.com
xLogic/x-Messenger wiring
I/O(Input/Output)wiring
Input DC12-24V (Digital,analog DC0..10V, high speed input)
CPU:PR-6DC,PR-12DC,PR-18DC,ELC12DC-N,EXM-12DC,PR-24DC
Extension:PR-E-16DC,EXM-E-8DC
3-wire PNP sensor
Contact
Digital input of CPU and Ext.
CPU:PR-12DC,PR-18DC,
ELC-22DC,EXM-12DC,PR-24DC
Extension:PR-E-16DC,EXM-E-8DC
CPU:PR-12DC,PR-18DC,
ELC-12DC,EXM-12DC,PR-24DC
DC 0..10V(input set to 0..10V)
Potentiometer type (input set to 0--10V)
Potentiometer(input set as a potentiometer)
Encode
High speed digital
input
Analog input(0...10V) of CPU or extension
Input AC110-240V (digital)
CPU:PR-6AC,PR-12AC,PR-18AC,ELC-12AC-N,EXM-8AC,PR-24AC
Extension:PR-E-16AC,EXM-E-8AC
Contact
Digital input of CPU and extension
Analog input signal(0/4...20mA, PT100 input)
CPU:EXM-12DC-DAI-R(I3,I4);
Extension:PR-E-AI-I,EXM-E-AI-I
0/4..20mA signal
0/4..20mA input terminal(I1,
CPU:EXM-8DC-PT100-R
Extension:PR-E-PT100,EXM-E-PT100
PT100 4-wire
PT100 3-wire
M1) of CPU and extension
PT100 2-wire
PT100 input terminal
CPU and extension
of
www.rievtech.com
20
xLogic/x-Messenger wiring
Relay Output
CPU:ELC-6,PR-12,PR-18,PR-24,,EXM series
Extension:PR-E-16,EXM-E-8
Relay of CPU or
Extension(Normally open)
Load(DC or AC)
Transistor output
CPU:PR-12-TN,,PR-18DC-DA-RT,PR-24DC-DAI-RTA,N,EXM-12DC-DA-RT series
Extension:PR-E-16-TN,EXM-E-8DC-TN
Transistor of CPU or extension(M
terminal need be connected with
L+)
Digital Output/PWM(Max.0.3A)
Analog Output(DC0..10V, 0/4....20mA)
DC 0..10V: PR-E-AQ-VI, EXM-E-AQ-V
0/4...20mA: PR-E-AQ-VI, EXM-E-AQ-I
0..10V terminal of Extension
0...20mA output terminal of Extension
Load: R>=5000R
Load: R<=250R
www.rievtech.com
21
xLogic/x-Messenger Technical Data
General environment characteristics for PR product types
Certifications
CE
Conformity to standards (with the low voltage
IEC/EN 61131-2 (Open equipment)
directive and EMC directive)
IEC/EN 61131-2 (Zone B)
IEC/EN 61000-6-2
IEC/EN 61000-6-3 (*)
IEC/EN 61000-6-4
Earthing
Not included
Protection rating
In accordance with IEC/EN 60529: IP20
Overvoltage category
3 in accordance with IEC/EN 60664-1
Pollution
in accordance with IEC 60068-2-42
in accordance with IEC 60068-2-43
Max operating Altitude
Operation: 2000 m
Transport: 3048 m
Mechanical resistance
Resistance to electrostatic discharge
Immunity to vibrations IEC/EN 60068-2-6
5 ... 8.4 Hz (constant amplitude 3.5 mm)
Immunity to shock IEC/EN 60068-2-27
8.4 ... 150 Hz (constant acceleration 1 g)
IEC/EN 61000-4-2 Severity 3
8 kV air discharge
6 kV contact discharge
Resistance to HF interference
Immunity to radiated electrostatic fields
IEC/EN 61000-4-3
Immunity to fast transients (burst immunity)
IEC/EN 61000-4-4, level 3
Immunity to shock waves
IEC/EN 61000-4-5 Severity 3
Radio frequency in common mode
IEC/EN 61000-4-6, level 3
Conducted and radiated emissions
Class B in accordance with EN 55022
Operating temperature
-20 ➞ +55°C in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2
Storage temperature
-40 ➞ +70℃ in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2
Relative humidity
10 ➞ 95 % . (no condensation or dripping water) in accordance with IEC/EN 60068-2-30
Mounting
On 35 mm standard mounting rail, 4 MW, or wall-mounting
Screw terminals connection capacity
Flexible wire with ferrule =
1 conductor: 0.25 to 2.5 mm2(AWG 24 ➞AWG 14)
2 conductors 0.25 to 0.75 mm2(AWG 24 ➞AWG 18)
Semi-rigid wire =
1 conductor: 0.2 to 2.5 mm2(AWG 25 ➞AWG 14)
Processing characteristics of PR-6,PR12, PR18,PR-24,EXM product types
PR-6 Series
PR-12-E
PR-12 series
EXM and
Without display
With display
ELC-12-N
PR-18 series
PR-24 series
series
Program size function blocks (FBD)
64
512
1024
Memory size function blocks (FBD)
4K
32K
64K
22
LCD display
No
4 lines of 16 characters and configurable backlighting
Programming method
Function block Diagram
Program memory
Flash EEPROM
Back-up time in the event of power failure
Program and settings in the controller: 10 years
Program and settings in the plug-in memory: 10 years
Data memory: 10 years
Cycle time
FBD:
Response time
Input acquisition time: + 1 to 2 cycle times
Clock data retention
25°C
Clock drift
typ. 0.6ms ➞ 8.0ms
typ. 20days
± 2 s/day
Timer block accuracy
1 % ± 2 cycle times
Start up time on power up
Typ. 4s
Unit
(resolution) :s :+10 ms
m :+1 s
Characteristics of products with AC power supplied
Supply
110 ➞ 240 V
Nominal voltage
110 ➞ 240 V
Operating limits
85 ➞ 265 V
Supply frequency range
47 ➞ 63 Hz
Immunity from micro power cuts
Max. absorbed power
ac
ac
ac
115 VAC typ. 10 ms
240 VAC typ. 20 ms
PR24: 130 mA (85V ac) ; 40mA (265V ac)
PR18: 49 mA (85V ac) ; 37mA (265V ac)
PR12(standard): 48.5mA (85V ac) ; 35mA (265V ac)
PR12(Economy): 38mA (85V AC); 30mA (265V AC)
PR16: 53 mA (85V ac) ; 38mA (265V ac)
PR 6: 34 mA (85V ac) ; 26mA (265V ac)
EXM-8AC-R:86 mA (85V ac);35mA (265V ac)
ELC-12AC-R-N: 51 mA (85V ac);37mA (265V ac)
Isolation voltage
1780V ac
Inputs
110 ➞ 240 V
Input voltage
110 ➞ 240 V ac
Input current
0.07 mA @ 85 V ac
ac
0.26 mA @ 265 V ac
Logic 1 voltage threshold
> 79 V ac
Making current at logic state 1
> 0.06 mA ac
Logic 0 voltage threshold
< 40 V ac
Release current at logic state 0
< 0.03 mA ac
Input Response Time
Delay time at 0 to 1:
Delay time at 1 to 0:
120V AC :Typ. 50 ms
120V AC :Typ. 90ms
240V AC:Typ. 30 ms
240V AC:Typ.100 ms
Maximum counting frequency
Normal 4 Hz ; High speed input:
Sensor type
Contact or 3-wire PNP
Input type
Resistive
Isolation between power supply and inputs
None
23
NO
h :+1 min
Isolation between inputs
None
Protection against polarity inversions
Yes
Status indicator
No, only can monitor with software
On LCD screen
Characteristics of relay outputs common to the entire range
Max. breaking voltage
AC 250 V
DC 110 V(0.1A)
Breaking current
DC30V(10A)
PR 6 Series, PR12 Series, PR16 Series(Q5-Q8), PR18 Series,PR24 Series, EXM Series: 10 A
PR16 Series(Q1-Q4), EXM-E Series : 3A
Electrical durability for 500 000 operating cycles
105 Operations at Rated Resistive Load
Max. Output Common Current
Type. 10 A with resistive load
But,(PR-E-16,Q1-Q4; EXM-E-8, Q1-Q2)
Type. 2 A with inductive load
Maximum rate
10 Hz
mechanical
2 Hz
resistive load
0.5 Hz
inductive load
Mechanical life
107
Response time
Operate Time : 15 mSec. Max.
3 A with resistive load
1 A with inductive load
Operations at No Load condition
Release Time : 10 mSec. Max.
Built-in protections
Against short-circuits: None
Against overvoltages and overloads: None
Status indicator
no
On LCD screen
Characteristics of product with DC power supplied
Supply
12 ➞ 24V dc
Nominal voltage
12 ➞ 24V dc
Operating limits
10.8 ➞ 28.8V dc
Immunity from micro power cuts
1 ms (repetition 20 times)
Max. absorbed power
PR24: 4.8 W (10.8V dc) ; 5 W (28.8V dc)
PR18: 3.5 W (10.8V dc) ; 4 W (28.8V dc)
PR12(standard):
-R: 3.2 W (10.8V dc) ; 3.8 W (28.8V dc)
-TN: 2 W (10.8V dc) ; 2.3 W (28.8V dc)
PR12(Economy): 3.5 W (10.8V dc) ; 4 W (28.8V dc)
PR16: 3.5 W (10.8V dc) ; 4.5 W (28.8V dc)
PR6: 1.1 W (10.8V dc) ; 1.2 (28.8V dc)
EXM:4 W (10.8V dc) ;4.5 W (28.8V dc)
Protection against polarity inversions
No
Digital inputs (I7 to IC for PR-18 , I5 to I8 for
12 ➞ 24V dc
PR-12, and I7 to IE for PR-24 )
Input voltage
12 ➞ 24V dc
Input current
2.3 mA @ 10.8V dc
2.6 mA @ 12.0 V dc
5.2 mA @ 24 V dc
6.5 mA @ 30.0 V dc
24
Transient current:1A (12V DC)
Logic 1 voltage threshold
> 8VDC
Making current at logic state 1
> 1.6 mA
Logic 0 voltage threshold
< 5 VDC
Release current at logic state 0
< 1.0 mA
Response time
0 to 1 :Typ. 1.5 ms ;<1.0 ms(PR18: I9-IC; PR12: I5-I8)
1 to 0 :Typ. 1.5 ms ;<1.0 ms(PR18: I9-IC; PR12: I5-I8)
Maximum counting frequency
PR18,PR-24:
I9- IC : 60K HZ
PR12(With LCD) I5- I8 : 60K HZ
EXM-12:
I7 , I8 : 60K HZ
Sensor type
Contact or 3-wire PNP
Input type
Resistive
Isolation between power supply and inputs
None
Isolation between inputs
None
Protection against polarity inversions
None
Status indicator
On LCD screen for PR12,PR18,PR-24 and EXM
Analog or digital inputs
12 ➞ 24V dc
PR18 and PR24 Series
6 inputs : I1 ➞ I6
PR12 Series
4 inputs : I1 ➞ I4
and
PR16Series,
PR-6, EXM-12 and ELC-12-N
Inputs used as analog inputs
Measurement range
(0 ➞ 10 V)
Input impedance
Min, 24KΩ ; Max. 72KΩ
Input voltage
28.8 V dc max.
Value of LSB
15 mV
Input type
Common mode
Resolution
10 bit/0.01V
Conversion time
300ms
Accuracy at 25 °C
± (Max.0.02)V
Accuracy at 55 °C
± (Max.0.04)V
Isolation between analog channel and power supply
None
Cable length
10 m max.
Protection against polarity inversions
NO
(PR-6DC,PR-12DC-DA-R-E,PR-E-16DC-DA-R,PR-E-16DC-DA-TN,EXM-E-8DC-DA-R:9bit ,0.015V)
shielded and twisted
Inputs used as digital inputs(PR18 and PR24 series:I1-I6,PR12 Series and PR16Series, PR-6, EXM-12 and ELC-12-N:I1-I4)
Input voltage
0 ➞ 28.8 V DC
Input current
0.4mA @ 10.8V dc
0.5mA @ 12.0 V dc
1.2mA @ 24 V dc
1.5mA @ 28.8 V dc
Input impedance
Min, 21KΩ ; Max. 72KΩ
Logic 1 voltage threshold
> 8 V dc
Making current at logic state 1
> 0.30 mA
Logic 0 voltage threshold
< 5 V dc
Release current at logic state 0
< 0.10 mA
25
Response time
ELC-6,PR-12 Series : 0 to 1 :Typ. 1.5 ms ;1 to 0 :typ. 1.5 ms
EXM-12,ELC-12-N,PR-18,PR-24 Series : 0 to 1 :Typ. 1.5 ms ;1 to 0 :Typ. 1.5 ms
PR16 extension Series : 2ms * n + (0 to 1 :Typ 1.5 ms ;1 to 0 :typ 1.5 ms)
n=1-16(number of extension is connected together
EXM8 extension Series : 2ms * n + (0 to 1 :Typ 1.5 ms ;1 to 0 :typ 1.5 ms)
n=1-16(number of extension is connected together
Maximum counting frequency
Typ. 4Hz
Sensor type
Contact or 3-wire PNP
Input type
Resistive
Isolation between power supply and inputs
None
Isolation between inputs
None
Protection against polarity inversions
None
Status indicator
No, but LCD can display for the CPU with LCD
Digital / PWM transistor outputs
12 ➞ 24V dc
PWM transistor outputs
PR-12DC-DA-TN : Q3 , Q4 ;
Breaking voltage
10.4 ➞ 30 V dc
Nominal voltage
≤ Supply voltage
Nominal current
Max. 0.3 A per channel
Max. breaking current
0.3A
Voltage drop
<1 V
Response time
Make
Frequency (Hz)
resistive load : 10 Hz
PR-18DC-DA-RT : Q5 , Q6;
for I = 0.3 A (at state 1)
≤ 1 ms
Release ≤ 1 ms
inductive load : 0.5 Hz
Built-in protections
Against overloads and short-circuits: NO
Against overvoltages (*): NO
Against inversions of power supply: YES
Min. Load
1 mA
Maximum incandescent load
0.3 A / 12 V dc
0.3 A / 24 V dc
Galvanic isolation
None
PWM frequency
10K HZ
PWM cyclic ratio
0 ➞ 100 %
PWM accuracy at 120 Hz
< 5 % (20 % ➞ 80 %) load at 10 mA
Max. Breaking current PWM
50 mA
Max. cable length PWM
20m
PWM accuracy at 500 Hz
< 10 % (20 % ➞ 80 %) load at 10 mA
Status indicator
No, but LCD can display for the CPU with LCD
26
PR-24DC-DAI-RTA : Q5 , Q6;
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement