2 Scene Controller with Switches - Single Pole (One Location)

2 Scene Controller with Switches - Single Pole (One Location)
2 Scene Controller with Switches - Single Pole (One Location)
Cat. No. VRCS2, 120/240VAC, 50/60Hz
Incandescent-1000W/Switch – Magnetic Low-Voltage-1000VA/Switch
Electronic Low-Voltage-1000W/Switch – Fluorescent-1000VA/Switch – Supplemental-1/4 HP/Switch
Installation Instructions
WARNINGS AND CAUTIONS:
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
• Vizia RF +™ electronic combo switches are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia RF +™ controllers.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Recommended minimum wall box depth is 2-1/2".
• Use this device only with copper or copper clad wire.
INSTALLING YOUR DEVICE
INTRODUCTION
Leviton’s Vizia RF +™ Z-Wave components are designed to communicate
with each other via Radio Frequency (RF) to provide remote control of
your lighting. Using RF technology allows Leviton to provide the greatest
signal integrity possible. Each module in Leviton’s Vizia RF +™ component
line is a Z-Wave® enabled device. In a Z-Wave® network, each device is
designed to act as a router. These routers will re-transmit the RF signal
from one device to another until the intended device is reached. This
ensures that the signal is received by its intended device by routing the
signal around obstacles and radio dead spots. The Scene Capable Combo
Switch is compatible with any Z-Wave® enabled network, regardless of
the manufacturer and can also be used with other devices displaying the
Z-Wave® logo.
®
Step 4
Single Pole Wiring Application:
Switch ON/OFF
Scene Capable
This is a Z-Wave® Controller
Can call 2 Scene Controller
ON/OFF LED
Two way communication
RF reliability
Ease of installation – No new wiring
Compatible with other Z-Wave® enabled devices
Step 1 WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is off
before wiring!
Black
1
White
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
2
Blue
5
Green
3
NOTE: If the wiring in your wall box does
not resemble any of these configurations,
consult a qualified electrician.
1
red
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load 1
5. Load 2
2
3
4
5
Black
Step 3 Preparing and connecting wires:
Black
Load
Tools needed to install your Device
Electrical Tape
Cutters
Pliers
Ruler
Changing the color of your Device
Your 2-Scene Controller with Switches includes three color options. The
device ships with the White frame attached. To change color of frame,
proceed as follows:
5/8"
(1.6 cm)
Cut
(if necessary)
Strip Gage
(measure bare
wire here)
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.
For non-standard wiring applications,
refer to Wire Nut and Connector Size Chart
WIRE CONNECTOR / # OF COND. COMBINATION CHART
Push in
side at tab
to release
Line up tabs and
press in sides one
at a time to attach
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
•
•
•
4
2 Scene Controller with Switches
Load
Slotted/Phillips Screwdriver
Pencil
Step 5 Testing your Switch prior to mounting
in wall box:
when Steps are completed.
Step 2 Identifying your wiring application (most common):
FEATURES
•
•
•
•
•
•
•
•
•
NOTE: Use check boxes
White
Hot (Black)
BL
BK
RD
WH
Green
Ground
Line
120/240VAC, 50/60Hz
Position all wires to provide room in outlet wall box for device.
Ensure that the word “TOP” is facing up on device strap.
Partially screw in mounting screws in wall box mounting holes.
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
• Restore power at circuit breaker or fuse.
• Press pad until locator light is OFF. Lights
should turn ON.
If lights do not turn ON, refer to the
TROUBLESHOOTING section.
Step 6 Switch Mounting:
White
Neutral (White)
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
WIRING COMBO 2-Scene Controller with Switches:
Connect wires per WIRING DIAGRAM as follows:
•
•
•
•
•
•
Green or bare copper wire in wall box to Green switch lead.
Line Hot wall box wire to Black switch lead.
Line Neutral wall box wire to White dimmer lead.
Load 1 wall box wire to Red switch lead.
Load 2 wall box wire to Blue switch lead.
Proceed to Step 5.
Installation may now be completed by tightening
mounting screws into wall box. attach wallplate.
Step 7 Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
DI-000-VRCS2-02A
Step 8 Including 2-Scene Controller with Switches
into Z-Wave® Network:
NOTES:
• If using a non-Leviton Programmer/Controller, refer to the
Programmer/Controller instruction sheet for Including a device.
• Controllers included into a Z-Wave network must be updated after
you have included all other devices
• If using VRCPG install checklist go directly to step B.
A) Follow These steps for Leviton Vizia RF+ Programmer/Controller,
Cat. No. VRCPG, press the Menu button and scroll down to System.
Press the center button to select System Menu. Choose Advanced
Settings. Press the center button to select Advanced Install. Press the
center button to select <Include Node>
B) You will be prompted to place 2-Scene controller into programming
mode.
C) To access Program mode press and hold buttons 1 and 2. Wait
approximately 5 seconds until the LED turns Amber. Release the
buttons and the LEDs will blink Amber. You are now in programming
mode.
NOTE: If the LED on the 2-Scene Controller turns solid Red while
including, there has been a communication error.
D) While standing close to the 2-Scene Controller with switch
(approximately 1 foot), press the center button on the
Programmer/Remote to <Include> device into network.
Note: Only one device may be included at any time
E) The Primary Programmer/Controller will assign a Home ID and Node
ID number for this device.
NOTE: This information will be stored in the Programmer/ Remote to
be used for future reference.
NOTE: You may name or edit your device at this time.
F) The 2-Scene Controller is now installed in the network. If using
Leviton VRCPG you will be automatically prompted to include load
1 and load 2, otherwise please proceed to Step G). If you would like
to use just as a controller press the "Back" button to proceed with
installation.
G) Including Local Switches:
*Remain in Advanced Settings
*Press Center Button to select Include switch 1
*The Primary Programmer/Remote will assign a Node ID switch 1.
*You may name or edit the device at this time
Note: To include Load 2, repeat Step G using Button 2.
H) After all devices are included into the network, the controller must be
updated. To update controller proceed as follows:
• If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for updating controller.
Step 8 cont’d
Step 9 cont’d
•
If using Leviton Z-Wave® Programmer/Remote, Cat. No. VRCPG, press
the Menu button and scroll down to System. Press the center button
to select System Menu. Choose Advanced Settings. Press the center
button to select Advanced Install. Select Update controller. Select your
controller from the list. Press center Button to begin update. Update
will start automatically. Stand within (1ft) of controller while updating
Network topology.
• Wait until the VRCPG Programmer/Remote confirms completion.
Update is done.
Note: If the 2-Scene controller with switches has been successfully
Included in the network and the user tries to Include it again without first
excluding it from the network, the node ID will remain the same.
Programmer/Controller
Cat. No. VRCPG
Menu
Button
B) To Exclude, press button 1. Switch 1 will exclude from your network.
NOTE: If the LED on the Load control turns solid Red while excluding,
there has been a communication error. Try excluding node again.
C) Repeat Steps above to exlcude Load 2, pressing Button 2
Excluding 2-Scene controller:
A) If using a Leviton Z-Wave® Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down to System. Press the center
button to select System Menu. Choose Advanced. Press the center
button to select Advanced Install. Scroll down to <Exclude Node> and
press the center button.
B) If using VRCPG Programmer/Remote, you will be prompted to place
2-Scene controller into programming mode.
C) To access program mode, press and hold buttons 1 and 2 (refer to
figure). Wait approximately 5 seconds until the LED turns Amber. Release
the buttons and the LED will blink Amber. You are now ready to exclude.
NOTE: If the LED on the 2-Scene controller turns solid Red while
excluding, there has been a communication error.
D) While standing close to the 2-Scene controller (approximately 1 ft.),
press the center button on the Programmer/Remote to <Exclude>
device from the network.
Factory Default:
1 ON
OFF
2 ON
OFF
3 ON
OFF
4 ON
OFF
Center
Button
Programmer/Controller
Cat. No. VRCPG
If your 2-Scene controller with switch is not responding, or you are unable to
control it after you have tried to Include/Exclude it multiple times, it may be
necessary to reset the 2-Scene controller with switch to its original factory
settings. To accomplish this, proceed as follows:
• On the 2-Scene controller with switch (refer to figure), press and hold
buttons 1 and 2. Wait approximately 10 seconds until the LED turns
Amber and then turns solid Red. Allow LED's to blink red twice, release
the buttons. The 2-Scene controller with switches is now reset. Once
the controller is reset, it will be necessary to Re-Include it to a network
before it can be used.
CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOES
NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE EXCLUSION
PROCEDURE MUST STILL BE FOLLOWED TO REMOVE THE DEVICE
FROM THE PRIMARY CONTROLLER’S INFORMATION TABLE. FAILURE
TO DO SO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND, OR
MAY FAIL TO RESPOND TO SOME DEVICES.
Step 10 Device Association:
NOTE: Programmer/Controller must be in close
proximity to 2-Scene Controller with Switches when
including in the network.
Step 9 Excluding 2-Scene Controller with Switches from
Z-Wave® Network:
Excluding Load Control:
A) If using a Leviton Z-Wave® Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down to System. Press the center
button to select System Menu. Choose Advanced. Press the center
button to select Advanced Install. Scroll down to <Exclude Node> and
press the center button.
After inclusion process, you may associate Vizia RF + light switches, to
buttons on the controllers. Refer to the Primary Programmer/Remote
instruction sheet for complete details.
NOTE: This step requires a controller that can create association lists to
specific groups.
NOTE: If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for associating a Vizia RF+ light
switch.
OPERATION
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON.
Turn OFF from ON position:
Tap – Lights turn OFF.
If there is a power outage, when the
power is restored, the lights will return
to the last setting before the power
interruption.
Cleaning: Clean with a damp cloth. DO
Push Pads
NOT use chemical cleaners.
Locator
Lights
TROUBLESHOOTING
•
•
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors of switch.
Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.viziarfplus.com
Protected under U.S. Patent Number 6,388,399 and patents pending
and licensed under U.S. Patents Numbers 5,905,442, and 5,982,103
FCC COMPLIANCE STATEMENT:
This device complies with Part 15 of the FCC Rules. Operation is subject to following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation
of the device.
This equipment has been tested and found to comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment OFF and ON, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION: Any changes or modifications not expressly approved by Leviton
Manufacturing Co., Inc., could void the user's authority to operate the equipment.
© 2009 Leviton Mfg. Co., Inc.
DI-000-VRCS2-02A
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,
at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, N.Y. 11747. This warranty excludes and there is disclaimed liability for labor for
removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement