GE DWSR405GBWW / DWSR405GBCC Gas Dryer

GE DWSR405GBWW / DWSR405GBCC Gas Dryer
GE Appliances
DWSR405GBWW/CC – GE Super 7.0 Cu. Ft. Capacity Dryer
Dryer Dimensions (in inches)
23-1/2
28-1/4
*24-1/2" from the edge of the side panel to the front.
25-1/2" from front to edge of endcaps.
25-1/2*
27
Exhaust Options:
When viewed from the front of the unit, exhaust 3-way via rear, left and bottom.
Dryer is shipped exhausted to the rear. Alternate exhausting knockouts are supplied.
Gas: An individual properly-grounded branch circuit, with a three-prong groundingtype receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse
is required.
Gas Dryer Electric Rating: 120V, 60Hz, 6A
8-1/2
36
42
2-1/2
Side View
11-1/2
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas
supply requires a conversion kit. Check installation instructions for correct kit and
have a qualified gas technician install a conversion kit. See dryer ducting information
for proper installation.
2
Note: Dryer wall outlet must be located within 36" of service cord entry and
accessible when dryer is mounted in position.
3-1/2
Installation Information: For complete information, see installation instructions
packed with your dryer.
Rear View
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
Specification Revised 3/03
GE Appliances
DWSR405GBWW/CC – GE Super 7.0 Cu. Ft. Capacity Dryer
Dryer Exhausting Information – Use Metal Duct Only
Vertical and Horizontal Ducting
For complete information, see installation instructions packed with your dryer.
Best Performance
Maximum Length of 4"
Dia. Rigid Metal Duct
Exhaust Hood Type
Maximum Length of 4"
Dia. Flexible Metal Duct
Exhaust Hood Type
Number
of
90°
Turns
A
4" Opening
B
2-1/2"
Opening
A
4" Opening
0
1
2
3
4
0
1
2
3
4
0
1
2
3
0
1
2
3
4
150 ft.
140 ft.
130 ft.
120 ft.
110 ft.
90 ft.
60 ft.
45 ft.
35 ft.
25 ft.
90 ft.
60 ft.
45 ft.
35 ft.
60 ft.
52 ft.
44 ft.
32 ft.
28 ft.
127 ft.
117 ft.
107 ft.
97 ft.
87 ft.
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
60 ft.
45 ft.
35 ft.
25 ft.
48 ft.
40 ft.
32 ft.
24 ft.
16 ft.
75 ft.
65 ft.
55 ft.
45 ft.
35 ft.
55 ft.
40 ft.
30 ft.
20 ft.
15 ft.
55 ft.
40 ft.
30 ft.
20 ft.
30 ft.
22 ft.
14 ft.
—
—
A
A
4
B
Domestic
Dryer Models
2-1/2
7.3 Capacity Electric
and Gas Dryers
7.0 and 6.0
Capacity Models
all Electric Dryers
7.0 and 6.0
Capacity Models
all Gas Dryers
5.7 Capacity Electric
and Gas Dryers
B
2-1/2"
Opening
52 ft.
42 ft.
32 ft.
22 ft.
12 ft.
45 ft.
30 ft.
20 ft.
15 ft.
10 ft.
45 ft.
30 ft.
20 ft.
15 ft.
18 ft.
14 ft.
10 ft.
—
—
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of
open area equally distributed. If this closet contains both a washer and a dryer, doors must contain
a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" both sides
3" rear
Specification Revised 3/03
Ducting Materials:
For best performance, this dryer should be vented with 4” diameter all rigid metal exhaust duct. If “all rigid metal”
duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended
duct length.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
The maximum length for flexible ducts are less than for rigid duct.
2. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint
from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed Down.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening
dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE CARES.
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
GE Appliances
DWSR405GBWW/CC – GE Super 7.0 Cu. Ft. Capacity Dryer
10 C
lo t h es
Care Cycle
COTTONS
COTTONS
ON
MED. HEAT
COOL DOWN
WRINKLE
CARE
LESS DRY
ON
MORE DRY
OFF
MORE DRY
OFF
DELICATES
REG. HEAT
LESS DRY
TIMED DRY
QUICK FLUFF 10
WRINKLE CARE
DEWRINKLE 20
DAMP DRY
DELICATES
FLUFF
EASY CARE
WRINKLE FREE
PERM. PRESS
OPTIMUM DRY
Extended Cool
Sensor
EASY CARE
START
SIGNAL
Electronic Tone
WRINKLEAirCARE
Tumble
CARE
FABRIC Dry
s • Super Capaci
ty
MORE DRY
LESS DRY
WRINKLE CARE
START
Deluxe Quiet
LOW HEAT
NO HEAT
Specification Revised 3/03
30
40
80
50
60
70
MIN
KNITS
Features and Benefits
• 7.0 cu. ft. Super Capacity Dryer
• Sensor Dry
• 4 Heat Selections
• 10 Cycles:
– Cottons with Auto Cottons and Optional Wrinkle Care
– Easy Care with Auto Easy Care and Optional Wrinkle Care
– Delicates with Auto Delicates and Optional Wrinkle Care
– Timed Dry (80 Min.) with Damp Dry, Dewrinkle and Quick Fluff (no heat)
• Deluxe End-of-Cycle Signal
• Deluxe Dryer Rack
• Dryer Interior Light
• Removable Upfront Lint Filter
• DuraDrum™ Interior
• Deluxe Quiet Performance
• Reverse-A-Door
• 100% Front Serviceable
• Model DWSR405EBWW – White on white (Electric)
• Model DWSR405EBCC – Bisque on bisque (Electric)
• Model DWSR405GBWW – White on white (Gas)
• Model DWSR405GBCC – Bisque on bisque (Gas)