Data sheet
Applications:
Ordering:
Specifications:
ABV Thermo-Hydraulic Actuator
Electronic Actuator
ABV
•
•
•
•
•
•
Low voltage, 24 volt thermo-hydraulic actuator
Normally open or Normally closed versions
Power consumption 9VA
Built-in manual operation
Built-in Cv limiting
ABV is recommended for flow temperature control as well as ON/OFF control in hot water systems.
Applications include heat exchangers, zone control for mixed loop systems, and storage tanks
• Use with type RAV, VMT, and KOVM 3-way valve
• Used on flow temperature or floor heating systems
Type
ABV-NO
ABV-NC
Code No.
082F0002
082F0052
Used with 2-way valve, ports are
Normally open
Normally closed
Used with KOVM, 3-way valve, ports B-AB
Normally open
Normally open
Valve
VMT
KOVM
Ordering No.
065F8960
065F8961
065F1242
013U3017
013U3015
013U3020
Style
2-way
3-way
Supply voltage
Frequency
Control signal
Consumption
Time for full spindle travel
Max. permissible spindle travel
Ambient temperature
Weight
Actuator mounted onto
Mounted orientation
Stem force
Pipe size
1/2”
3/4”
1”
1/2”
Cv
3.3
5.9
9.4
1.75
2.34
Connection type
Double solder unions
Male NPT unions
Female NPT
Compression fittings
24 V ~ +30%, -15%
50-60 Hz
2-point (ON/OFF)
9VA
< 9 min
ABV-NO: 4mm
ABV-NC: 2.2mm
32-140°F (0-60°C)
0.6 lb
2-way: RAV, VMT / 3-way: KOVM
Any orientation, except upside down
18 lbf (80N)
VDLEA122 © Danfoss 09/07 1
Data sheet ABV Thermo-Hydraulic Actuator
Electronic Actuator
Electrical
Connections:
Mechanical
Connection:
RAV / VMT
/ KOVM
1-5/16” (34 mm) outside diameter
Manual control:
ABV has a collar that is marked with arrows indicating settings for manual and automatic operation.
Manual Operation Return to Automatic Operation
Lift collar up.
Rotate base counter clockwise until right arrow
( ) aligns with A on the collar.
Lift collar up.
Rotate base clockwise until triangle ( ) aligns with A on collar.
Push collar down.
For the ABN-NC, the valve can be opened manually by turning the collar in a counterclockwise direction as indicated. Likewise when fitted with ABN-NO, the valve can be manually closed by turning the collar in a clockwise direction
VDLEA122 © Danfoss 09/07 2
Data sheet ABV Thermo-Hydraulic Actuator
Electronic Actuator
Automatic control settings:
Operation:
The ABV when mounted to the VMT has the unique ability of provide automatic control with or without
Cv limitation. When the collar is raised, the scale setting is exposed.
A
With the right triangle ( , AUTO) set to “A” on the collar’s scale, there will be a full flow rate through the valve, i.e. the entire travel of the valve stem and 100% of the valve’s Cv. If the triangle ( ) is set to any other position along the collar’s scale, the maximum stem travel will be reduced resulting in a reduced flow rate and Cv value.
Normally closed actuator Normally open actuator
RAV/ VMT
KOVM
VDLEA122 © Danfoss 09/07 3
Data sheet ABV Thermo-Hydraulic Actuator
Electronic Actuator
Dimensions:
RAV
A
B
L
C
H
VMT
A
B
L
C
H
KOVM
B
A
C
G
AB KOVM
A
B
L
D
E
F
Size
1/2”
3/4”
1”
1/2”
3/4”
1”
1/2”
Type
RAV
VMT
KOVM
H
4.4”
4.4”
4.9”
4.4”
4.4”
4.9”
L
2.3”
L
3.7”
4.2”
4.9”
4.1”
4.8”
5.7”
D
1.1”
A
B
C
2.8”
2.0”
3.6”
E
1.1”
F
1.0”
G
4.6”
Typical specification:
The electronic actuator shall be a 2-wire thermo-wax actuator powered by 24 volts AC.
The signal to the actuator shall be ON/ OFF.
The actuator shall have manual operator and integrated Cv limitation for control in hot water systems. The applications for the actuator shall be for linear actuation for 2-way and 3-way valves for normally open or normally closed applications. The electronic actuator shall be an
ABV thermo-wax actuator.
Danfoss can accept no responsibility for possible errors in printed materials and reserves the right to alter its products without notice.
All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Inc.
6711 Mississauga Road, Suite 410
Mississauga, ON, L5N 2W3
Tel.: 905-285-2050, Fax: 905-285-2055 www.na.heating.danfoss.com
Danfoss Inc.
7941 Corporate Drive
Baltimore, MD 21236 USA
Tel.: 443-512-0266, Fax: 443-512-0270 www.na.heating.danfoss.com
VDLEA122 © Danfoss 09/07
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement