User Guide EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Add to my manuals
32 Pages

advertisement

User Guide EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler | Manualzz

United Kingdom

en

User Guide

Gas Fired Wall Mounted Condensing Boiler

EcoBlue Advance Heat

13 - 16 - 19 - 25 - 30

Please keep these instructions in a safe place.

If you move house please hand them over to the next occupier.

Model Range

Baxi EcoBlue Advance 13 Heat ErP

G.C.N

o 41 470 34

Baxi EcoBlue Advance 16 Heat ErP

G.C.N

o 41 470 35

Baxi EcoBlue Advance 19 Heat ErP

G.C.N

o 41 470 36

Baxi EcoBlue Advance 25 Heat ErP

G.C.N

o 41 470 37

Baxi EcoBlue Advance 30 Heat ErP

G.C.N

o 41 470 38

Dear Customer,

Thank you for purchasing this appliance.

Please read this manual carefully before using the product and keep it in a safe place for future reference.

In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained. Our Service and

After Sales organization can assist with this.

We hope you will receive many years of satisfactory service.

ISO 9001

FM 00866

0086

© Baxi Heating UK Ltd 2015 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and

Patents Act 1988.

Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:

The Company Secretary, Baxi Heating UK Limited,

Brooks House, Coventry Road, Warwick. CV34 4LL

Full acknowledgement of author and source must be given.

WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.

The Benchmark Scheme

Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.

Benchmark is managed and promoted by Heating and Hotwater

Industry Council. For more information visit www.centralheating.co.uk

2 EcoBlue Advance Heat 7219720 - 01 (04/15)

6

7

Contents

1

2

3

4

5

Introduction

1.1

General

1.2

1.3

1.4

1.5

Additional Documentation

Symbols Used

Abbreviations / Glossary

Extent of Liabilities

1.5.1

1.5.2

1.5.3

Manufacturer’s Liability

Installer’s Responsibility

User’s Responsibility

Safety

2.1

2.2

General Safety Instructions

Recommendations

2.2.1

Benchmark Commissioning Checklist

Technical Specifications

3.1

Technical Data

3.1.1

Clearances

Description of the Product

4.1

General Description

4.2

4.3

4.4

4.5

Operating Principle

4.2.1

In Operation

Control Panel Description

4.3.1

User Interaction Controller

4.3.2

Indicator Lights

Standard Delivery

Accessories & Options

4.5.1

Optional Extras

Operation

5.1

Operation Checking Procedure & Basic Fault Identification

5.2

5.3

Shutdown

Frost Protection

Settings

6.1

Setting the Boiler Flow Temperature

Maintenance

7.1

General

7.2

7.3

7.4

7.5

Maintenance Instructions

Filling the System

Venting the System

Draining the System

Contents

16

16

18

18

18

18

19

19

19

20

21

22

9

9

10

10

11

11

12

7

8

8

7

7

6

6

6

6

13

13

14

15

15

15

13

13

14

14

7219720 - 01 (04/15) EcoBlue Advance Heat 3

8

9

10

11

12

13

Contents

Troubleshooting

8.1

Fault Warning & Lock-out Codes

8.2

Fault Finding

Decommissioning

9.1

Decommissioning Procedure

Disposal

10.1

Disposal / Recycling

Environmental

11.1

Energy Saving

11.2

Room Thermostats and Settings

Warranty

12.1

General

12.2

Terms of Warranty

12.2.1

Standard Warranty Terms and Conditions

Appendix

13.1

ErP Information

13.1.1

Product Fiche - Boiler Space Heaters

13.1.2

Package Fiche - Boilers

26

26

26

27

27

27

27

29

29

29

30

23

23

24

25

25

25

25

4 EcoBlue Advance Heat 7219720 - 01 (04/15)

This page is intentionally blank

7219720 - 01 (04/15) EcoBlue Advance Heat 5

1 Introduction

1 Introduction

1.1 General

1.2

Additional Documentation

1.3

Symbols Used

6 EcoBlue Advance Heat

All Gas Safe registered engineers carry an ID card with their licence number and a photograph. You can check your engineer is registered by telephoning 0800 408 5500 or online at www.gassaferegister.co.uk

This manual is intended for the user of the Baxi EcoBlue

Advance Heat boiler. If the appliance is sold or transferred, or if the owner moves leaving the appliance behind you should ensure that the manual is kept with the appliance for consultation by the new owner and their installer.

The appliance is designed as a boiler for use in residential domestic environments on a governed meter supply only. The selection of this boiler is entirely at the owner’s risk. If the appliance is used for purposes other than or in excess of these specifications, the manufacturer will not accept any liability for resulting loss, damage or injury.

The manufacturer will not accept any liability whatsoever for loss, damage or injury arising as a result of failure to observe the instructions for use, maintenance and installation of the appliance.

Various timers, external controls, etc. are available as optional extras. Full details are contained in the relevant sales literature.

In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, prevent hazards and guarantee correct operation of the appliance.

DANGER

Risk of a dangerous situation causing serious

physical injury.

WARNING

Risk of a dangerous situation causing slight physical

injury.

CAUTION

Risk of material damage.

Signals important information.

Signals a referral to other instructions or other pages

in the instructions.

7219720 - 01 (04/15)

1.4

Abbreviations / Glossary

1.5

Extent of Liabilities

Introduction 1

DHW: Domestic Hot Water

CH: Central Heating

GB: Great Britain

IE: Ireland

BS: British Standard

HHIC: Heating and Hotwater Industry Council

1.5.1. Manufacturer's Liability

Our products are manufactured in compliance with the requirements of the various european applicable Directives.

They are therefore delivered with marking and all relevant documentation. In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.

The manufacturer will not accept any liability for loss, damage or injury arising as a result of:-

Failure to abide by the instructions on using the appliance.

Failure to regularly maintain the appliance, or faulty or

inadequate maintenance of the appliance.

Failure to abide by the instructions on installing the

appliance.

This company declares that no substances harmful to health are contained in the appliance or used during appliance manufacture.

The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force, and only used in a suitably ventilated location.

In GB, the installation must be carried out by a Gas Safe

Registered Installer. It must be carried out in accordance with the current and relevant requirements of legislation and guidance.

Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice.

In IE, the installation must be carried out by a competent person and installed in accordance with the current edition of I.S. 813

‘Domestic Gas Installations’, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation.

Incorrect installation could invalidate the warranty and may lead to prosecution.

7219720 - 01 (04/15) EcoBlue Advance Heat 7

1 Introduction

8 EcoBlue Advance Heat

1.5.2 Installer's Responsibility

The installer is responsible for the installation and initial start up of the appliance. The installer must adhere to the following instructions:

Read and follow the instructions given in the manuals

provided with the appliance.

Carry out installation in compliance with the prevailing

legislation and standards.

Ensure the system is flushed and inhibitor added.

Install the flue/chimney system correctly ensuring it is

operational and complies with prevailing legislation and

standards, regardless of location of the boiler’s installation.

Only the installer should perform the initial start up and carry

out any checks necessary.

Explain the installation to the user.

Complete the Benchmark Commissioning Checklist in the

Installation Manual - this is a condition of the warranty !

Warn the user of the obligation to check the appliance and

maintain it in good working order.

Give all the instruction manuals to the user.

1.5.3. User's Responsibility

To guarantee optimum operation of the installation, you must observe the following instructions:

Read and observe the instructions given in the manuals

supplied with the appliance.

Seek the assistance of a qualified installer for the installation

and initial commissioning.

Ask the installer to explain the installation.

Have the required annual inspection and maintenance

carried out by a qualified installer and ensure the Benchmark

Service Record in the Installation Manual is completed - this

is a condition of the warranty !

Keep the manuals in good condition and near to the

appliance.

This appliance must not be used by people with a lack of experience or knowledge, unless they are supervised by someone familiar with the appliance or if they have been instructed on how to operate the appliance correctly. Do not allow children to operate or play with the appliance.

7219720 - 01 (04/15)

Safety 2

2 Safety

2.1

General Safety Instructions

7219720 - 01 (04/15)

DANGER

If you smell gas:

1. Turn off the gas supply at the meter

2. Open windows and doors in the hazardous area

3. Do not operate light switches

4. Do not operate any electrical equipment

5. Do not use a telephone in the hazardous area

6. Extinguish any naked flame and do not smoke

7. Warn any other occupants and vacate the

premises

8. Telephone the National Gas Emergency Service

on:- 0800 111 999

The boiler can be isolated at the gas valve under the

appliance by turning the tap through 90° ( 1 /

4 turn).

For advice please contact your Installer, Annual

Service Provider or Baxi Customer Support - The

Service Division of Baxi. You can contact Baxi

Customer Support on telephone number 0344 871 1525.

When contacting Baxi Customer Support it will be useful

to have the ‘Benchmark Checklist’ at the back of the

Installation & Service Manual to hand as it includes details

relevant to the boiler and installation.

WARNING

Do not touch flue/chimney pipes. Depending on the settings of the appliance, the temperature of flue/chimney pipes may exceed 60 °C.

Do not touch radiators for long periods. Depending on the settings of the appliance, the temperature of radiators may reach 85 °C.

Take precautions with domestic hot water. Depending on the settings of the appliance, domestic hot water temperature may reach 65 °C.

CAUTION

Do not neglect to service the appliance. Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance.

EcoBlue Advance Heat 9

2 Safety

2.2

Recommendations

CAUTION

Only qualified professionals are authorised to work on the appliance and the installation.

For sealed systems regularly check the water

pressure in the system (recommended pressure is

1.5 bar). Your installer will advise on the method of

repressurising if required.

Keep the appliance accessible at all times.

Do not remove or cover the serial number label

affixed to the slide-out flap at the boiler lower left.

It must remain legible throughout the

lifetime of the appliance.

2.2.1 Benchmark Commissioning Checklist

1. Please ensure that the installer has fully completed the

Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales).

2. All installations must be notified, by the installer, to Local Area

Building Control either directly or through a Competent Persons

Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the

Notification Number on the Benchmark Checklist.

3. This product should be serviced annually to optimise its safety, efficiency and performance. The service engineer should complete the relevant section of the Benchmark Service Record in the Installation & Service manual after each service.

4. The completed Benchmark Checklist & proof of annual servicing (where applicable) will be required in the event of any warranty work.

See Section 12 for warranty information.

10 EcoBlue Advance Heat 7219720 - 01 (04/15)

Technical Specifications 3

3 Technical Specifications

3.1

Technical Data

NOTE: All data in this section are nominal values and subject to normal production tolerances.

Flow Temperature (adjustable)

30° C to 80° C (± 5° C)

Outercase Dimensions

Overall Height

Inc Flue Elbow

- 790mm

Casing Height - 625mm

Casing Width - 370mm

Casing Depth - 280mm

Clearances

Both Sides 5mm Min

Above Casing

(Top Flue)

190mm Min

Above Casing

(Rear Flue)

35mm Min

Below Casing

(in Cupboard)

35mm Min

Below Casing 120mm Min

Front (For Servicing) 800mm Min

Front (In Operation) 5mm Min

Ventilation of Compartment

Where the boiler is installed in a cupboard or compartment, no air vents are required for cooling purposes providing that the minimum dimensions above are maintained.

Electrical Supply 230V~ 50Hz

(Appliance must be connected to an

earthed supply)

Power Consumption

13 model 17W

16 model 20W

19 model 23W

25 model 33W

30 model 44W

External Fuse Rating 3A

7219720 - 01 (04/15) EcoBlue Advance Heat 11

3 Technical Specifications

3.1.1. Clearances

1. A flat vertical area is required for the installation of the boiler.

2. These dimensions include the necessary clearances around the boiler for case removal, spanner access and air movement

(Figs. 1 & 2). Additional clearances may be required for the passage of pipes around local obstructions such as joists running parallel to the front face of the boiler.

5mm Min 370mm

5mm Min

190 mm

At least

1.5°

Fig. 1

At least

1.5°

Fig. 2

12 EcoBlue Advance Heat

800mm Min

For Servicing

Purposes

625mm

270mm

5mm Min

In Operation

5mm Min 370mm

800mm Min

For Servicing

Purposes

5mm Min

35mm Min in Cupboard

120mm Min

625mm

35mm Min* in cupboard (cut-outs required for pipework)

85mm Min* below ceiling (allows access to compression fittings on pipe)

5mm Min

In Operation

35mm Min in Cupboard

120mm Min

7219720 - 01 (04/15)

Description of the Product 4

4 Description of the Product

4.1

General Description

Information

Label

1. The Baxi EcoBlue Advance Heat is a wall mounted condensing boiler which is room sealed and fan assisted, and will serve central heating and stored domestic hot water

2. The boiler will be one of the following outputs:-

13 kW

16 kW

19 kW

25 kW

30 kW

3. The boiler is factory set for use only on Natural Gas (G20).

4. The boiler model, serial number and Gas Council number are shown on the information label under the boiler (Fig. 3). This is for user reference.

Slide

Forward

4.2

Operating Principle

Fig. 3

4.2.1 In Operation

1. Whilst the boiler is in operation cooled flue gases are discharged through the flue gas discharge pipe. This may appear as a cloud of steam which is normal.

2. Condensed water is discharged from the boiler heat exchanger into a pipe (the condensate drain). This pipe must never be altered or re-routed except by a qualified professional.

7219720 - 01 (04/15) EcoBlue Advance Heat 13

4 Description of the Product

4.3

Control Panel Description

Fig. 4

Fig. 5

Normal Operation - The green light remains on for around seven seconds and then extinguishes briefly, repeating the sequence whilst the boiler is operating.

The symbol indicates the Status Light ON.

LED

ON

LED

OFF

Fig. 6

Light ON (approx. 7 sec.)

1 flash OFF

Time

1 flash OFF

Upper Horizontal Line = Light ON

Lower Horizontal Line = Light OFF

Time

14 EcoBlue Advance Heat

4.3.1 User Interaction Controller (Fig. 4)

Key to symbols:-

Heating Water Temperature

Sweep Key and Status Signals

Reset button and On/Off Signal

1. The User Interaction Controller has 2 illuminating push buttons which provide information about the operating condition of the boiler.

2. The RESET button illuminates green when the boiler receives a demand for CH or DHW.

3. The button can flash orange, green or red and at different frequencies.

4. The User Interaction Controller also has one rotary knob. The

rotary knob is used to set the maximum flow temperature of the heating water.

5. The temperature selected by the rotary knob must be set to a higher temperature than the cylinder thermostat to achieve the required hot water demand.

4.3.2 Indicator Lights (Fig. 5)

The colour of the status light on the boiler control panel and the number of times that it flashes indicates whether the boiler is working normally, has a problem or requires servicing.

See Section 8.1. for details of the fault conditions.

Boiler Operating The light will flash orange at EVERY heating demand. The number of flashes will correspond with the heat output of the boiler. This is normal and does not indicate a fault condition. During normal running illuminates green and blinks off momentarily every seven seconds approximately to show the boiler is running normally and supplying heat (Fig. 6).

Error When flashing green light indicates that the boiler has detected a problem, and is attempting to resolve it. If it does not succeed the boiler will go into fault mode and display a red light.

Defect When flashing red light indicates that the boiler has a fault. Press the RESET button for a minimum of 5 seconds to try and clear the fault condition.

A lock-out condition can be re-set up to 5 times within one hour using the reset button. Any fault that occurs repeatedly should be fully investigated and appropriate remedial actions taken by your installer or Baxi Customer Support.

If there is a continuous red light, contact your installer or Baxi

Customer Support

The lights will be OFF when there is no demand for heat.

7219720 - 01 (04/15)

4.4

Standard Delivery

4.5

Accessories & Options

Description of the Product 4

1. The literature pack contains:

Literature pack

• Installation & Servicing Manual

(including ‘benchmark’)

• User Guide Instructions

• Flue Accessories & Fitting Guide

• Registration Card

• Fernox Leaflet

• Wall Template

• Product Leaflet

• Package Leaflet

4.5.1 Optional Extras

1. Various items are available as optional extras.

Flue Accessories (elbows, extensions, clamps etc.)

(refer to the Flue Accessories & Fitting Guide supplied

in the literature pack.)

Remote relief valve kit

1M Condensate Drain Pipe ‘Trace Heating’ Element

2M Condensate Drain Pipe ‘Trace Heating’ Element

3M Condensate Drain Pipe ‘Trace Heating’ Element

5M Condensate Drain Pipe ‘Trace Heating’ Element

Any of the above MUST be fitted ONLY by a qualified competent person. Further details can be found in the relevant sales literature and at www.baxi.co.uk

7219720 - 01 (04/15) EcoBlue Advance Heat 15

5 Operation

5 Operation

5.1

Operation Checking Procedure & Basic Fault Identification

START

Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). If the property has a prepayment meter ensure it has sufficient credit.

NO

If no gas, consult your supplier.

YES

Typical examples of external timer

Is the Timer ON and calling for heat ?

10

11

12

1

7

NO

6

5

2

CH ON CH OFF

YES

Is the Room Thermostat (if fitted) set high enough ?

NO

5

10

15

20

25

Turn Room Thermostat to maximum setting (typical example shown)

Ensure timer is set for Central

Heating ON (see any instructions supplied with timer)

5

10

15

20

25

NO

Boiler fails to light ?

NO

Press the Reset Button

If boiler will not light.

CONTACT

YOUR

INSTALLER OR

SERVICE

ENGINEER.

Reset Button

16 EcoBlue Advance Heat 7219720 - 01 (04/15)

Operation 5

YES

Is there electricity to the boiler ?

YES

NO

Check the fused spur to the boiler is in the on position.

Switch on.

NO

YES

Ignition Spark will commence

YES

Boiler flame established

(Both lights are on)

If the boiler fails to operate. Contact your

Installer.

Chimney Sweep /On

Button /Light

Reset

Button/Light

YES

Boiler operating satisfactorily.

NO

If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible

7219720 - 01 (04/15) EcoBlue Advance Heat 17

5 Operation / Settings

5.2

Shutdown

5.3

Frost Protection

1. If it is anticipated that the boiler will not be used for a long period or the property is to be unoccupied it is recommended that the system is drained if the electricity & gas supplies are to be turned off. Your installer will be able to offer advice.

1. To prevent radiators and the system from freezing in rooms where there is a risk of frost (e.g. a garage or storage room), a frost thermostat can be connected to the system

6 Settings

6.1

Setting the Boiler Flow Temperature

To increase or decrease the boiler temperature:-

1. Turn the rotary knob to the right (Fig. 7) to increase the boiler temperature.

2. Turn the rotary knob to the left (Fig. 7) to decrease the boiler temperature.

3. To achieve the required domestic hot water temperature the rotary knob must be set to a higher temperature than that selected on the cylinder thermostat.

Rotary Knob - Boiler

Temperature Adjustment

+

-

Fig. 7

18 EcoBlue Advance Heat 7219720 - 01 (04/15)

Maintenance 7

7 Maintenance

7.1

General

7.2

Maintenance Instructions

1. The boiler does not require any special maintenance.

However, the boiler must be serviced annually in accordance with the Installation and Service Manual and the relevant section of the Benchmark Service Record completed in order to maintain the warranty.

Taking out a maintenance contract is recommended.

CAUTION

Maintenance operations must be performed by a

qualified competent person.

Use only genuine spare parts.

2. The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING

AGENTS.

1. The central heating system should be checked regularly.

Proceed as follows:

For Sealed Systems

If the water pressure is lower than 0.7 bar, the water must be topped up. If necessary: top up the CH system

(recommended water pressure between 1 and 2 bar).

• Check radiators for leaks and (especially in damp areas) for rust.

• Open and close the radiator valves several times a year to ensure they can still be rotated.

• Only clean the outside of the boiler with a damp cloth. Do not use abrasive cleaning agents.

CAUTION

Only a qualified installer may clean the inside of the

boiler.

7219720 - 01 (04/15) EcoBlue Advance Heat 19

7 Maintenance

7.3

Filling the System

The boiler will be installed on either an open-vented or sealed

(pressurised) heating system. If you are unsure which type of system you have consult your installer.

Sealed systems may require periodic re-pressurisation. If this is required on a regular basis a fault or leak is indicated. Seek advice from your installer.

20 EcoBlue Advance Heat 7219720 - 01 (04/15)

7.4

Venting the System

1

2

10

4

3

1

2

4

A

6

5

C

B

7

Maintenance 7

If any air is present in the appliance or system it must be removed in order to prevent nuisance noises that may occur during operation. The boiler has an inbuilt auto air vent to aid the removal of air and is supplied in the open position. Proceed as follows:

1. Open the valves of all the radiators connected to the

system.

2. Set the room thermostat to the highest possible

temperature and any timers to ‘ON’.

3. Wait until the radiators are warm.

4. Switch off the boiler.

5. Vent the radiators. Work from the lowest radiator in the

property.

6. Open the bleed vent with the key, keeping a cloth

pressed against the vent.

7. Wait until water comes out of the bleed vent and then

close.

WARNING

The CH water in the radiators will still be hot.

8. Switch the boiler on.

9. After venting, if the system is of the sealed (pressurised)

type check that the water pressure is still adequate.

For sealed systems - if the water pressure is lower than

0.7 bar, the water must be topped up (recommended

water pressure between 1.0 and 1.5 bar when the

system is cold).

10. Reset the room thermostat to the desired temperature..

7219720 - 01 (04/15) EcoBlue Advance Heat 21

7 Maintenance

7.5

Draining the System

1

2

3

1

2

4

5

It may be necessary to drain the CH system if radiators need to be replaced or removed, if there is a major water leak or if there is a risk of freezing. Proceed as follows:

1. Open the valves of all the radiators connected to the

system.

2. Switch off or disconnect the boiler’s electrical isolation point.

3. Wait until all the radiators are cold.

4. Connect a drain hose to the lowest draining point. Place the

end of the hose in a drain or at a place where drained

water will not cause any damage.

5. Open the CH system drain valve. Drain the system.

WARNING

The CH water may still be hot.

6. When water stops flowing from the draining point, close the

draining valve.

See Section 7.4 Venting the system. If in doubt seek advice from your installer.

After draining the concentration of system corrosion

inhibitor and anti-freeze may become excessively diluted -

seek advice from your installer.

4

22 EcoBlue Advance Heat 7219720 - 01 (04/15)

Troubleshooting 8

8 Troubleshooting

8.1

Fault Warning & Lock-out Codes

No. of

Flashes

1

2

3

4

5

6

Green Light

Flashing

Red Light

Flashing

Temperature

Protection

Shutdown

Input

Flame

Loss

Communication

Fault

Parameter

Fault

Sensor

Error

High Temperature

Protection

Ignition

Fault

Fan

Fault

Parameter

Fault

Miscellaneous Miscellaneous

1. The colour of the status light on the boiler control panel and the number of times that it flashes indicates whether the boiler is working normally, has a problem or requires servicing.

Fault - Warning When flashing green light indicates that the boiler has detected a problem, and is attempting to resolve it. If it does not succeed the boiler will go into lock-out mode and will display a red light.

Fault - Lock-out When flashing red light indicates that the boiler has a fault and has locked out. Press the RESET button for a minimum of 5 seconds to try and clear the fault condition.

2. A lock-out condition can be re-set up to 5 times within one hour using the reset button. Any fault that repeats regularly should be fully investigated and appropriate remedial actions taken by your

Installer, Annual Service Provider or Baxi Customer Support -

The Service Division of Baxi.

3. If there is a continuous red light, contact your Installer, Annual

Service Provider or Baxi Customer Support - The Service

Division of Baxi, and inform them of the fault code displayed.

4. You can contact Baxi Customer Support on 0344 871 1525.

When contacting Baxi Customer Support it will be useful to have the ‘Benchmark Checklist’ at the back of the Installation &

Service Manual to hand as it includes details relevant to the boiler and installation.

LED

ON

LED

OFF

LED

ON

LED

OFF

LED

ON

LED

OFF

LED

ON

LED

OFF

LED

ON

LED

OFF

LED

ON

LED

OFF

The symbol indicates the flashing Status Light.

1 flash

Time

1 flash

Time

2 rapid flashes

Time

2 rapid flashes

Time

3 rapid flashes

Time

3 rapid flashes

Time

4 rapid flashes

Time

4 rapid flashes

5 rapid flashes

Time

5 rapid flashes

6 rapid flashes

Time

6 rapid flashes

Upper Horizontal Line = Light ON

Lower Horizontal Line = Light OFF

Time

Time

Time

LED

ON

LED

OFF

Normal Operation

The symbol indicates the Status Light ON.

Light ON (approx. 7 sec.)

1 flash OFF

Time

1 flash OFF

Upper Horizontal Line = Light ON

Lower Horizontal Line = Light OFF

Time

7219720 - 01 (04/15) EcoBlue Advance Heat 23

8 Troubleshooting

8.2

Fault Finding

1. If the boiler is not working, check section 5.1 Operation Checking Procedure & Basic Fault

Identification or the fault finding table. Contact your Installer.

Problem

There is no domestic hot water and/or the radiators are cold.

The boiler is not working.

Possible Causes

Check that the boiler is being supplied with power

(all controls set to ON).

Check the fuses and the switches.

If possible check whether the gas cock is properly open.

If the property has a prepayment meter ensure it has sufficient credit.

Check if the Fault - Lock-out is illuminated. See

Section 8.1 to reset.

The domestic hot water is not hot enough.

The boiler temperature setting is below the cylinder thermostat setting.

The radiators are not hot enough.

The radiator valves are not open.

The temperature set point for the heating is too low (check boiler & room thermostat).

24 EcoBlue Advance Heat 7219720 - 01 (04/15)

Decommissioning / Disposal 9 / 10

9 Decommissioning

9.1

Decommissioning Procedure

CAUTION

Only qualified professionals are authorised to

work on the appliance and system to decommission.

1. If your the boiler needs to be decommissioned either temporarily or permanently the following should be performed:

• Switch off the boiler.

• Switch off the boiler’s electrical connection.

• Close the boiler gas valve.

• Drain the CH system.

Seek the advice of your installer.

10 Disposal

10.1 Disposal / Recycling

WARNING

Removal and disposal of the boiler must be carried

out by a qualified installer in accordance with local

and national regulations.

7219720 - 01 (04/15) EcoBlue Advance Heat 25

11 Environmental

11 Environmental

11.1

Energy Saving

11.2

Room Thermostats and Settings

Tips on saving energy:

Do not cover radiators. Do not hang curtains in front of

radiators.

Install reflective panels behind the radiators to prevent heat

losses.

Insulate the pipes in rooms that are not heated (cellars and

lofts).

Install loft insulation & double glazing.

Use draught excluders where necessary.

Upgrade any older external controls.

Turn down room thermostats by 1°C

Turn off radiators in rooms not in use.

Do not run hot (or cold) water pointlessly.

Fit a water-saving shower head to save up to 40 % energy.

Take showers rather than baths. A bath consumes twice as

much water and energy.

Various models of room thermostats are available. The thermostat type and setting affect the total energy consumption.

A few tips:

Fully opening or closing thermostatic radiator valves result in unwanted temperature fluctuations. Turn the thermostat knob or valve higher or lower in small steps.

Lower the thermostat to approximately 20°C. This reduces heating costs and energy consumption.

When rooms are to be aired, lower the thermostat well in advance.

When setting thermostats or programmers take account of days when nobody will be in and of holidays.

26 EcoBlue Advance Heat 7219720 - 01 (04/15)

12 Warranty

12.1 General

12.2 Terms of Warranty

Warranty 12

To make sure your boiler warranty is activated and maintained, it is essential that the:

1. Benchmark checklist is completed by your installer

2. Warranty is registered with Baxi

3. Boiler has an annual service

Please note that failure to adhere to terms and conditions will make your warranty invalid.

12.2.1 Standard Warranty Terms and Conditions

Warranty Registration, Service & Repair

For full terms and conditions, visit www.baxi.co.uk/terms.

Benchmark Checklist

The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly. It can be found at the back of the installation and service manual and should be kept in a safe place for the life of the boiler. We will check that the Benchmark Checklist has been completed on an in-warranty visit.

Ways to register your warranty

If your boiler is eligible for an extended warranty, your installer may register the product on your behalf and provide you with the relevant documentation. Please check with your installer.

Should this not be the case, you can register your warranty online at www.baxi.co.uk/registration

7219720 - 01 (04/15) EcoBlue Advance Heat 27

12 Warranty

Information

Label

Slide

Forward

Annual Service

A service must be completed every 12 months from the date of installation to maintain your warranty.

This service must be completed by one of the following:

• A Gas Safe registered installer/engineer

• Baxi Customer Support; call us 0344 871 1525

Please make sure that your engineer has logged the service information at the back of the installation and service manual.

You will be asked for your service history on any in-warranty repair visit.

If you experience a problem with your boiler

For any in or out of warranty repair, Baxi Customer Support is on hand to help you. Call our award-winning team to arrange for one of our nationwide team of Gas Safe registered engineers to visit.

If your product is in warranty, everything is free of charge, subject to our warranty terms and conditions. If it is out of warranty, we can still help and offer a range of options you can choose from to suit your needs.

Contact Baxi Customer Support 0344 871 1525

Opening hours

Monday - Friday, 8.00am - 6.00pm

Weekends and Bank Holidays, 8.30am - 2.00pm

Please note calls may be recorded for training and monitoring purposes.

When contacting Baxi Customer Support, please have the following information to hand:

• Boiler serial number. This can be found on the

appliance.

• Proof of purchase if you do not have the boiler serial

number.

Please note that for in-warranty repairs, our engineers will ask to see your service history record, completed Benchmark

Checklist and details of your installer. These can all be found in the installation and user manual.

28 EcoBlue Advance Heat 7219720 - 01 (04/15)

Appendix 13

13 Appendix

13.1 ErP Information

13.1.1. Product Fiche - Boiler Space Heaters

Product fiche for boiler space heaters

Baxi EcoBlue Advance Heat ErP

Seasonal space heating energy efficiency class

Rated heat output

(Prated or Psup)

Seasonal space heating energy efficiency

Annual energy consumption

Sound power level L

WA

indoors kW

% kWh

GJ dB

13

A

13

93

11183

40

32

16

A

16

93

13764

50

33

19

A

19

93

16344

59

34

25

A

25

93

21506

77

37

30

A

30

93

25807

93

41

See

For specific precautions about assembling, installing and maintaining,

consult the relevant section as detailed on the Contents page.

7219720 - 01 (04/15) EcoBlue Advance Heat 29

13 Appendix

13.1.2. Package Fiche - Boilers

Package fiche for boilers indicating the space heating energy efficiency of the package

S e a s o n a l s p a c e h e a t i n g e n e r g y e f fi c i e n c y o f b o i l e r

T e m p e r a t u r e c o n t r o l

f r o m fi c h e o f t e m p e r a t u r e c o n t r o l

C l a s s I = 1 % , C l a s s I I = 2 % , C l a s s I I I = 1 .

5 % ,

Class IV = 2%, Class V = 3%, Class VI = 4%,

Class VII = 3.5%, Class VIII = 5%

+

S u p p l e m e n t a r y b o i l e r

f r o m fi c h e o f b o li e r

S e a s o n a l s p a c e h e a t i n g e n e r g y e f fi c i e n c y ( i n % )

S o l a r c o n t r i b u t i o n A N D S u p p l e m e n t a r y h e a t p u m p

s e l e c t s m a ll e r v a l u e

4

( - ‘I’ ) x 0.1 = ±

S o l a r c o n t r i b u t i o n

f r o m fi c h e o f s o l a r d e v i c e

C o ll e c t o r s i z e ( i n m ² ) T a n k v o l u m e ( i n m ³ ) C o

%) ll e c t o r e f fi c i e n c y ( i n

(1)

T a n k r a t i n g

A* = 0.95, A = 0.91,

B = 0.86, C = 0.83,

D - G = 0.81

(‘III’ x + ‘IV’ x ) x 0.9 x ( /100) x = +

( 1 ) I f t a n k r a t i n g i s a b o v e A , u s e 0 .

9 5

S u p p l e m e n t a r y h e a t p u m p

f r o m fi c h e o f h e a t p u m p

S e a s o n a l s p a c e h e a t i n g e n e r g y e f fi c i e n c y ( i n % )

( - ‘I’ ) x ‘II’ = +

5

‘I’

1

2

3

4

5

6

%

%

%

%

%

%

S e a s o n a l s p a c e h e a t i n g e n e r g y e f fi c i e n c y o f p a c k a g e

7

%

S e a s o n a l s p a c e h e a t i n g e n e r g y e f fi c i e n c y c l a s s o f p a c k a g e

A

+

A

++

A

+++

G

<30%

F E D C B A

B o i l e r a n d s u p p l e m e n t a r y h e a t p u m p i n s t a l l e d w i t h l o w t e m p e r a t u r e h e a t e m i t t e r s a t 3 5 ° C ?

f r o m fi c h e o f h e a t p u m p

7

+ (50 x ‘II’) = %

30

T h e e n e r g y e f fi c i e n c y o f t h e p a c k a g e o f p r o d u c t s p r o v i d e d f o r i n t h i s fi c h e m a y n o t c o r r e s p o n d t o i t s a c t u a l e n e r g y e f fi c i e n c y o n c e i n s t a in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the ll e d products in relation to building size and characteristics.

AD-3000743-01

I

II

The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %.

The factor for weighting the heat output of preferential and supple mentary heaters of a package as set out in the following table.

EcoBlue Advance Heat 7219720 - 01 (04/15)

Appendix

13.1.2. Package Fiche - Boilers (cont)

13

The value of the mathematical expression: 294/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater.

The value of the mathematical expression 115/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater.

Weighting of boilers

Psup / (Prated + Psup)

(1)(2)

0

0.1

0.2

II, package without hot water storage tank II, package with hot water storage tank

0

0.3

0.55

0

0.37

0.70

0.3

0.4

0.5

0.6

0.75

0.85

0.95

0.98

0.85

0.94

0.98

1.00

≥ 0.7

1.00

1.00

(1) The intermediate values are calculated by linear interpolation between the two adjacent values.

(2) Prated is related to the preferential space heater or combination heater.

Package efficiency

Baxi EcoBlue Advance Heat ErP

Temperature control X

Temperature control Y

%

%

13 16 19 25 30

7219720 - 01 (04/15) EcoBlue Advance Heat 31

Baxi Customer Support

0344 871 1525

Opening hours

Monday - Friday, 8.00am-6.00pm

Weekends and Bank Holidays, 8.30am-2.00pm

Please note calls may be recorded for training and monitoring purposes

baxi.co.uk

Register now to activate your warranty:

www.baxi.co.uk/registration

For the warranty to be maintained, please make sure...

1

2

3

Benchmark checklist is completed

Warranty is registered with Baxi

The boiler has an annual service

For full terms and conditions, visit www.baxi.co.uk/terms. Failure to adhere to terms and conditions will void your manufacturer’s warranty.

Baxi

Brooks House,

Coventry Road,

Warwick, CV34 4LL

Please ensure the boiler is installed in accordance with these installation instructions and that you adhere to the Building Regulations.

e&oe

All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request.

7219720 - 01 (04/15)