OUTDOOR INSTALLATION WARNING
IMPORTANT SAFETY PRECAUTIONS:
LIVES MAY BE AT RISK! Carefully observe these instructions and any special instructions that are included with the equipment you are installing.
IMPORTANT: Look over the site before beginning any installation, and anticipate possible hazards, especially these:
CONTACTING POWER LINES CAN BE LETHAL. Make sure no power lines are anywhere where possible contact
can be made. Antennas, masts, towers, guy wires or cables may lean or fall and contact these lines. People may be injured or
killed if they are touching or holding any part of equipment when it contacts electric lines. Make sure there is NO possibility
that equipment or personnel can come in contact directly or indirectly with power lines.
Assume all overhead lines are power lines.
The horizontal distance from a tower, mast or antenna to the nearest power line should be at least twice the total length of the
mast/antenna combination. This will ensure that the mast will not contact power if it falls either during installation or later.
TO AVOID FALLING, USE SAFE PROCEDURES WHEN WORKING AT HEIGHTS ABOVE GROUND.
•
•
•
•
•
•
Select equipment locations that will allow safe, simple equipment installation.
Don’t work alone. A friend or co-worker can save your life if an accident happens.
Use approved non-conducting ladders and other safety equipment. Make sure all equipment is in good repair.
If a tower or mast begins falling, don’t attempt to catch it. Stand back and let it fall.
If anything such as a wire or mast does come in contact with a power line, DON’T TOUCH IT OR ATTEMPT TO MOVE IT. Instead, save your life by
calling the power company.
Don’t attempt to erect antennas or towers on windy days.
MAKE SURE ALL TOWERS AND MASTS ARE SECURELY GROUNDED, AND ELECTRICAL CABLES CONNECTED TO ANTENNAS
HAVE LIGHTNING ARRESTORS. This will help prevent fire damage or human injury in case of lightning, static build-up, or short circuit within equipment
connected to the antenna.
•
•
•
The base of the antenna mast or tower must be connected directly to the building protective ground or to one or more approved grounding rods, using 1 O AWG
ground wire and corrosion-resistant connectors.
Refer to the National Electrical Code for grounding details.
Lightning arrestors for antenna feed coaxial cables are available from HyperLink Technologies, Inc.
IF A PERSON COMES IN CONTACT WITH ELECTRICAL POWER, AND CANNOT MOVE:
•
•
•
DON’T TOUCH THAT PERSON, OR YOU MAY BE ELECTROCUTED.
Use a non-conductive dry board, stick or rope to push or drag them so they no longer are in contact with electrical power.
Once they are no longer contacting electrical power, administer CPR if you are certified, and make sure that emergency medical aid has been requested.
Copyright © This drawing is property of L-com Global Connectivity. All rights reserved.
L-com Global Connectivity | 50 High St., West Mill, 3rd floor, Suite #30 | North Andover, MA 01845 | USA
© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com Logo are registered marks.
Toll Free Ordering and Technical Support: 1-800-343-1455
www.L-com.com
AL-D4W-05 / AL-D8W-12 Installation Instructions
1. Slots required in Cable Grommet to insert wires. (Cable Grommet
is removable)
2. If using a jacketed type cable, strip back cable jacket and then strip the stranded
wires. Loosen the individual screw terminals and insert the wire strands into the
terminal blocks, tighten screw to secure wire. The pc board should be removed
to ease wiring and ensure proper insertion of the stranded wires.
3. Attach ground wire to the included Ground Lug (12 AWG max.) and attach
it to terminal inside the protector. This ground lug can be mounted below
the pc board if attaching an additional shielding ground to the protector's
ground terminal (see diagram below).
Screw
Terminals
Ground
Terminal
Grounding Note: To ensure proper operation of protector, install an
earth ground to the ground lug in the protector. Please refer to the
National Electric Code (or your local codes) for additional information
or contact a licensed electrician for assistance.
Ground Lug
Screw
Terminals
4. If mounting this unit to a wall or other surface, break-away holes are
provided on the rear of the unit.
Note: This unit provides Bi-Directional Protection, input and output
cables may be interchanged.
Optional Lug for
Ground Terminal
Shielded Cable
Nut
Break-Away Holes
Washers
PCB
Cable Grommet
Washer
2"
Ground Lug
Protector Cross Section
AIP-00091 Rev. A – 01/07 Page 2/2
Note: This unit provides Bi-Directional
Protection, input and output cables may
be interchanged.
Copyright © This drawing is property of L-com Global Connectivity. All rights reserved.
L-com Global Connectivity | 50 High St., West Mill, 3rd floor, Suite #30 | North Andover, MA 01845 | USA
© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com Logo are registered marks.
Toll Free Ordering and Technical Support: 1-800-343-1455
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement