Add to my manuals
20 Pages

advertisement

 | Manualzz

FCC Warning

This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference to household appliances, in which case the user will be required to correct the interference at his/her own expense.

CE Mark Warning

This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Caution

Risk of Explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

Disclaimer

Contents in this User Guide are subject to changes without prior notice.

Table of Contents

Table of Contents ................................................................................................................................. iii

Quick Installation ................................................................................................................................. 1

Flash Upgrade Operation Guide (Using Windows HyperTerminal) .................................................. 7

Serial Command Set ........................................................................................................................... 10

iii

Quick Installation

Thank you for purchasing TK-RP08.

TK-RP08 can be used

Features

together with a host PC to control the power on/off of up to 8 servers/AC-powered devices. With our highly reliable and

Hardware

quality product, user can enjoy countless benefits from using it.

Can be used alone or cascaded with multiple units for power control of 8 to 100 more AC-powered devices

Unit management using a host PC connected via serial interface (RS-232)

Allows full control of 8 AC power outlets using ASCII commands over a serial interface

Cascadable up to 16 units and control up to 128 AC power outlets, using UTP cables over RJ-45 interfaces

Last known port status of each port retained and

TK-RP08 – Serial Power Control Unit

Introduction

The TK-RP08 provides 8 AC power outlets and can be deployed alone with a host PC for serial power control of any

AC-powered devices. The TK-RP08 proves to be a reliable solution that offers cost-effective power control to enterpriselevel customers. optionally restored when restarted after unit power down

Timer setting restored when restarted after unit power down

Numerical display to show power unit bank number when in multiple cascaded application

Numerical display to monitor total current loads

(showing 0.0 ~ 15A)

8 green (ON/OFF) LED indicators to show the ON/OFF status of each A/C power outlet

8 red (Alarm) LED indicators to show the state of failure of each AC power outlet

“One-Touch" power ON/Off control by front-panel buttons (with 2” time-delay for activation/deactivation

To control your AC-powered devices, you only need to tap them to any of TK-RP08’s 8 power output outlets and then connect the TK-RP08 to a host PC installed with the Power

Management software. To power on/off the connected ACpowered devices, you only need to press the front-panel upon button release)

Internal battery to retain unit configuration and port status/timer settings.

19" rack-mountable design with metal case button (press and hold for 2 seconds to activate/deactivate

TK-RP08 Management Software

power port upon button release); or you can use the power management software. The software is installed on a host

PC and provides a virtual front-panel that allows user to click to power on/off any connected devices. It also provides timer function to preset the destined power on/off time or power-up duration for each of your devices either at specific time or for recurrences.

The TK-RP08 is also capable of cascading with multiple units into a daisy-chained configuration to maximize the port

Intuitive user interface with virtual front-panel, power buttons and LED indicators

Current loads (per port/total) and bank number displays

Auto-configuration of COM port

Power On/Off Timer function

Simultaneous Power on/off all ports of one/all banks

Power On/Off confirmation dialog prompt

Power activation/deactivation based on duration/specific time point/daily-weekly recurrence timer settings capacity up to one hundred more. Thus you can easily control up to hundred of AC-powered devices and/or servers.

Before you install

Before you connect your devices to TK-RP08, please verify

TK-RP08

connected to a host PC

You might need to use extra adapter cords between ioPower and your devices, especially when the devices are not of the plug specification that fits the standard power outlets on the backpanel of ioPower. that the specifications are appropriate for your usage, for example: the output voltage should be in accordance with that required by your devices; and the total power loads and the power loads per port should not exceed the maximum total/per port output within its specification. Also the installation and operation should adhere to the local safety regulations.

Out-of-the-box Installation

Take the out of the box and begin installation….

Step 1. Connect the TK-RP08 to the power outlet via its power chord.

Step 2. Connect a host PC serial port to the serial port on the TK-RP08 backpanel, using a serial (RS-232) cable, then power on the host PC.

Step 3. Insert the TK-RP08 Support CD-ROM into the CD-

ROM drive of the Host PC, and then install the IP

1

Management Software on your host PC. (Refer to

next section for more details).

Step 4. Connect your AC-powered devices each to one of the eight power output outlets on TK-RP08 backpanel. Now you can control the power-on/off of your AC-powered devices by the (1) pressing and hold a front-panel button by over 2 seconds and release it to activate/deactivate the power port, or (2) using the management software interface on the host PC.

The front-panel buttons implement a time-delayed and action upon button release mechanism to prevent accidental pressing of the button to

Step 5. Run the ioPower Management Software,

Step 5-1. Run IP Management Software

Step 5-2. Select Setting/Connect to connect to TK-

RP08.

Step 5-3 Select Setting/Configuration to configure the connection settings and the timer settings. (refer to the following sections).

Easy Front-panel Operation

To control the power on/off via the TK-RP08

Management

Software Interface or set the timer to control the power on/off time of any of your devices, please refer to the following instructions.

Front-panel

Alarm LED: (Red)

Current Loads Display

Power ON LED: (Green)

Rear panel – for the US Region

POWER Reset button

Power Button

Bank Number Display

Power Input

( IEC 320 C14 )

11-~240 Vac@60Hz

Daisy-chain port (RJ-45)

- Stack-in (upper)

- Stack-out (lower)

Serial port

(RS-232)

Power Output

(UL-498 5-15R)

Rear panel – for the EU Region

POWER Reset button

Power Input

( IEC 320 C14 )

11-~240 Vac@60Hz

Daisy-chain port (RJ-45)

- Stack-in (upper)

- Stack-out (lower)

Serial port

(RS-232)

Power Output

(IEC 320 C13)

You might need to use extra adapter cords between ioPower and your devices, especially when the devices are not of the plug specification that fits the standard power outlets on the backpanel of

TK-RP08. These adapter chords are not included with your package carton and are available by optional purchase.

“One-touch” Power ON/OFF via Front-panel Button

To power ON/OFF any connected device, simply press and hold the corresponding Power Button for over 2 seconds to toggle your device On and Off upon button release.

Press and hold for 2 “ ….

Press and hold for 2 “ ….

Powered Off Powered-On Powered-Off

Release! Release!

By default, each port is in powered-off state when TK-RP08 is powered on.

Install ioPower Management Software

Step 1. Insert the Support CD-ROM disc to your host PC

CD-ROM Drive. (or you can download the installer program from available support website)

Step 2. The installer program will auto-run when you

insert the Support CD to your CD drive. (If not, then double-click the installation program executable file to start program installation.)

Step 3. Follow subsequent instructions to finish installation.

Step 4. After you have finished installation, you will see a desktop icon and an TK-RP08 program group appears within the Programs menu.

Desktop Icon

(TK-RP08 Management Software)

2

Connect host PC to ioPower

Now you can begin connecting your ioPower to the host

PC

Step 1. Run the TK-RP08 Management software by doubleclicking its desktop icon or access Start /programs

/ioPower/ioPower Management.

Now get yourself a little bit familiar with the Management

Software interface ……….

Power Management Software Interface

When running the TK-RP08 Management Software, you should see a virtual front-panel identical to the physical frontpanel. If you are cascading multiple units of TK-RP08 (using the RJ-45 daisy-chain interfaces connected by a UTP cable), you can then see a corresponding number of stacked virtual front-panels, each of which showing its bank number, the total current loads and time remaining status per port.

Alarm LED (Red) Power ON LED (Green)

Current Loads Display

Power Button

Step 2. Connect the host PC to TK-RP08 by clicking

Setting/Connect. And the software will automatically detect

COM port for TK-RP08 ….

Check the COM port detection message on the message

Box. After the COM port has been successfully detected, click OK to connect.

Note that if you see the FAIL message such as in the following picture, it means you have a faulty connection. Check your physical

COM port connection to make sure that everything is in place, including the connectors and RS-232 cable integrity, etc.

Global Power Action Button

Bank Number Display

Time Remain

Virtual front-panels showing a single unit

Virtual front-panel operation

The virtual front-panel serves just like a real front-panel to provide “one-touch” power on/off function. Just click each virtual button to switch the power on and off

Press and hold for 2 “ ….

Press and hold for 2 “ ….

Powered Off Powered-On Powered-Off

Release! Release!

However, to avoid accidental mistakes, TK-RP08

Management software will, by default, pop up a prompt for confirmation of this change after you click the virtual power button.

Failure of COM port detection

Step 3. Then you can see the virtual front panel of the connected TK-RP08 unit(s).

3

Power on/off confirmation dialog prompt

User can have free choice to disable/enable the confirmation prompt according one’s convenience.

Menu Function

File/Exit (Ctrl-X)

To exit the management program, click File/Exit or use the hotkey, Ctrl-X.

Setting/Connect

When TK-RP08 is disconnected with host PC, click

Setting/Connect to connect to host PC.

Setting/Disconnect

When TK-RP08 is connected with host PC, click

Setting/Disconnect to disconnect it from host PC.

Setting/Configuration

Click Setting/Configuration to access the TK-RP08

Configuration interface. You can use this dialog box to configure your COM port setting, Auto-connection and Power

ON/OFF confirmation prompt setting.

Then select the correct firmware upgrade file, e.g. TK-RP08

_V.x.x.x_dddddd.x Then click Open to start firmware upgrade.

The General Setting Tab

<Select COM port>: you can select Auto for auto- configuration of COM port, or you can specify your COM port setting as any of the available COM ports.

<Auto-connect to TK-RP08 on Start>: Check this option if you want to automatically connect to TK-RP08 when the management software is started. (Auto-connect is disabled by default)

<Touch-Panel Power ON/OFF Confirmation Prompt>: Check this option if you want a confirmation prompt pops up to confirm the Power ON/OFF change with you. (Confirmation

Prompt is enabled by default).

<Auto-sync system time with host time on start>: Check this option if you want to synchronize TK-RP08 system with PC system time every time when you start ioPower Management

Software.

<Restore last known port status on start on start>: Check this option if you want to restore the last known port status of each port when TK-RP08 unit is restarted.

Tools/Upgrade

Once TK-RP08 firmware upgrade is available, you can either get it from your local dealer or download it from available network resources. First, copy the firmware upgrade file to your host computer, and then access Tool/Upgrade to open the file locator dialog box.

You can also use the Windows HyperTerminal to perform firmware upgrade, please refer to the Firmware Upgrade Operation

Guide that comes with your firmware upgrade file. Normally, your

TK-RP08 unit is loaded with the latest firmware, you should have no need to reload/upgrade your firmware unless (1) there’s a new firmware upgrade ready (2) your firmware is corrupted and need reloading.

Tools/Check Version

To check the firmware version of Bank x (x = 1 ~ 16) of cascaded TK-RP08 units, just click Tools/Check

Version/Bank x to show the firmware version information in a small message box.

4

Time/ Set Timer

On this Time/Set Timer setting, you can specify whichever

port on whichever bank (of all available banks) to power on/off at a preset time point (within 23 hours 59 minutes) or

after certain duration (within 99 hours 59 minutes). After you have hit the Apply button, the enabled settings will be

registered and put into action accordingly, and each entry date/time will be shown.

Tickers showing remaining time for power actions

(still more than 21 minutes to go for a Power-On on all ports)

Note that the timer settings will also be executed nonetheless when (1) the host PC is shut down, or (2) the

TK-RP08

Management Software is disconnected to the

TK-RP08

. And the ioPower unit will also retain the last known port status of each port and will optionally restore each port to its last known status when ioPower is powered on again. However, if the

TK-RP08

Unit has been powered down itself, it would lose all its previous timer settings and need to be reconfigured or reloaded with (previous) timer settings once again.

Note that if you use the timer function to power on/off your device, the confirmation dialog prompt will not pop up for your confirmation just as you use the virtual front-panel button. Since it is assumed that you have intended to power on/off the specific device as you have planned… Therefore, timer will go directly to power on/off the device without warning you once the time is due.

When you input a value that is beyond the acceptable range of a setting field, a warning prompt will appear to warn you for incorrect input.

The Timer Setting Tab

Just use the series of check boxes and drop down combo boxes to specify the bank/port and time/duration for a power on/off.

There are several timer setting modes for selection:

After … to specify power on/off after specific duration

At … to specify power on/off at preset time

Every day … to specify daily power on/off at preset time

Every week …to specify weekly power on/off at preset day & time

To validate a specific timer setting item, just check the

Enable checkbox and press Apply to validate them, and press OK to save and exit.

To invalidate a specific timer setting item, just uncheck the Enable check box, press Apply and then OK to save and exit.

To set timer settings on Bank x, hit the Bank x tab to select the specific timer setting page of Bank x, and then configure the timer accordingly.

To clear all timer settings on Bank x, just hit the Clear

Bank x button and then hit Apply button to validate.

To save the timer settings on a bank to a file, just hit the

Save button to save the settings on your current bank into a file.

To load timer settings of a bank from a file, just hit Load button and find the timer setting file to load.

To clear all timer settings of all banks, just hit the Clear All button, and then hit Apply button to validate.

After the timer setting is enabled for a specific port, you will see a count down timer ticker under that specific port on the virtual front-panel of your TK-RP08 Management Software interface, and the alarm LED (red) will be flashing for a reminder. When within one minutes to power action, the ticker number will be flashing.

5

Range of hour settings

Global Power Action Button

Range of minute settings

TK-RP08 also allows you to perform global Power ON/OFF actions on all ports of a specific bank or of all cascaded banks….

Click the Global Power Action button on the lower left of the virtual touch panel will evoke a Quick Menu for global power action such as power on/off all ports of a specific bank or all banks.

Global Power Action Menu

On the Global Power Action Menu, you can choose the following power on/off options:

Power on all ports of a Bank x, x = 1~16

Power off all ports of a Bank x, x = 1~16

Power on all ports of all banks.

Power off all ports of all banks.

Just select any of these options for simultaneous power on/off all ports on a specific bank or on all banks, and a confirmation prompt will appear to ask you for confirmation.

Click OK to validate the action you selected.

The Confirmation Dialog Prompt

You can also access the timer setting interface on the Global

Power Action Menu as well as to check the firmware version of any specific bank of the daisy-chained TK-RP08 units.

System Requirements

Operation

Mode

Requirements

Used with a

Host PC

• a Win-based Host PC (with TK-RP08

Management Software installed)

Serial (RS-232) Cable for connection with host

UTP cable (only for cascading multiple units of ioPower)

Specifications

Model Name

Input Voltage

Output Voltage

AC Output

Front-panel control

Host connection

User interface

Cascade level

TK-RP08

100 ~ 240 VAC @ 50~60 Hz

100 ~ 240 VAC @ 50~60 Hz

(Depending on power input)

8 total

8 Power buttons

Serial RS-232 interface (DB-9)

Host PC / ioPower Management

Software

Up to 16 units

Cascade interface

RJ-45 (via UTP cable)

Max. current loads per port

6 amp per port

Current Overload

Protection

15 amp max.

Operating Temperature

0~45°C

Operating humidity

Storage Temperature

Storage Humidity

Dimensions (L x W x H)

10~90% RH

-20 ~ 70°C

0~90% RH

410 x 165 x 44.5 mm

Troubleshooting

An Alarm LED is Lit (Red)

In normal condition, the Alarm LED should never be lit.

However, when the Alarm LED is lit, it indicates that the corresponding power output port is put out of function by a hardware error, which prevents this port to power on or off.

If you see a lit Alarm LED, you should first disconnect the device connected with it and then try to troubleshoot by pressing several times its power button on the front-panel of

TK-RP08, to see if the Alarm LED still remains lit persistently.

If so, it indicates that this port is malfunctioning for good and need technical service from your local dealer.

When a port is currently scheduled with a Timer setting for later power on/off, its alarm LED (red) will be flashing for a reminder.

Also when you perform a firmware upgrade on

TK-RP08

, all the alarm LEDs will be flashing while it is still in process. In these conditions, flashing red LEDs do not indicate a problem.

Current Overloads Warning - A Flashing Numerical LED display (Red)

If the total current loads exceed 15 AMP-- the maximum allowable current loads of TK-RP08 --the numerical display of the current loads (Red) will be flashing. If you see the flashing Numerical LED display, it means TK-RP08 is now suffering form a current overloads. If that is the case, you should try to shutdown some devices to keep the current loads within its reasonable range.

Circuit Breaker Open Due to Current Overloads

If the total current loads exceed 15 AMP, the circuit breaker device might be activated to physically break off the internal circuit for safety and stop the function of TK-RP08. To restart the unit, just press the Power Reset button on the back panel.

Firmware Upgrade Not Successful or Firmware

Corrupted

If your firmware upgrade has not succeeded or your firmware is somehow corrupted and could no longer function anymore, your current loads LED display will show forth a message such as “OP”. If you see such message on your current loads display, please upgrade your firmware once more or check the integrity of your firmware code.

Port Error (unable to power on) Port Error (unable to power off)

While an alarm LED is lit, the timer setting interface on your

TK-RP08

Management Software will also show forth the

“invalid” message and block all sequent setting possibility on that malfunctioned port.

6

Flash Upgrade Operation Guide

(Using Windows HyperTerminal)

Important Note: Besides using Windows HyperTerminal for TK-RP08 flash upgrade, you can also use the Tools/Upgrade option on the IP Management Software Menu. Please refer to the Quick Installation section on this User Guide.

Click OK.

The TK-RP08 allows its user to upgrade firmware contents whenever is needed to enhance its functionality and/or performance. With the firmware upgrade feature, your investment on the unit is further ensured and its life-time value

Step 3. Select COM 1 or COM 2 (depending on r actual COM port configuration). In this case, we select COM 1. just maximized. You don’t have to buy a newer unit just to have better features, instead you can have them all added to your current unit with an easy flash upgrade! The correct Flash upgrade procedure is described below. Please follow the instructions to complete your firmware upgrade.

Flash Upgrade Procedure

Before you can perform a flash upgrade, you should have (1) a powered-on PC with an available RS-232 port (DB9) (2) the TK-

RP08

Unit to be upgraded, and (3) a RS-232 cable (DB9 to-DB9) connected already to RS-232 ports on both your PC and the ioPower

Unit.

AND also…..

Pease be sure to have (4) the latest flash upgrade file (

*.x

) ready on your local computer. You can copy them from the diskette/CD-ROM provided by the technical support or download it from available support website.

Check the connection between the

TK-RP08

Unit and PC

Make sure you have powered on the PC and also the

TK-RP08 Unit before you perform the flash upgrade procedure.

Step 1. Connect your PC and the TK-RP08 Unit using a RS-

232 cable.

Setting the Windows HyperTerminal

Once you have successfully established a serial connection, the settings will be stored on your PC and a shortcut with the connection’s name generated under your HyperTerminal program menu. Next time, you can establish the connection again simply by clicking the connection shortcut without going over the procedure in this section again. If that is the case, just click the connection shortcut and go right to the last section,

Flash Upgrade File Transfer

.

Step 2. On your PC (which should already be connected to your ioPower Unit with a DB9-to-DB9 RS-232 cable), activate the Windows HyperTerminal

(Start/Programs/Accessories/Communications/Hyper

Terminal). Designate your HyperTerminal connection with a specific name, e.g. Power Control 01.

Click OK.

Step 4. Configure your port setting with the following parameters:

Bits per seconds: 9600

Data bits: 8

Parity: None

Stop bits: 1

Flow Control: Hardware

Click Apply then click OK. Then HyperTerminal windows appears…..

Step 5. Hit Enter key twice to go into command mode …..

7

Flash Upgrade File Transfer

Step 7. To start loading the file, access the drop-down menu on HyperTerminal: Transfer/Send Text File….

If the firmware version is lower than 040421, here you should type in /

TK-RP08

\ on the command line and then hit

Enter

to go into command mode.

On the HyperTerminal window, you’ll see the Testing

OK message and the existing firmware version number…..

….and a dialog box will prompt you to select the flash upgrade file, *.x (with a file extension name as .x). In this case, we have our flash upgrade file as TK-RP08

3.0.1_040907.x (it could be any other file name with an .x extension!). Note that since it has an extension name other than .txt, we have to select the “All file

[*.*]” option in order to see it on the file listing…

Step 6. Type Upgrade on the command line and hit

Enter…Now you have your HyperTerminal ready for file transfer. Keep your HyperTerminal window open and go to the next step….

Then select our target file: PowerGate.hex.bin.x. And then Click Open to begin the file transfer …..

8

When the file transfer is completed, you will see the message: OK!! Please Restart on the HyperTerminal window to tell you that Flash Upgrade process is successful….

Step 8. After you have successfully upgraded the flash firmware and before you utilize the TK-RP08 Unit, you should perform a system reset by powering down the unit. Wait for a few seconds and then complete the reset again.

Troubleshooting

If the flash upgrade procedure seems never ending or you see the following message:

Please send new firmware

, shown on the screen, it indicates that the flash process had failed. If that is the case, please power off the TK-RP08 Unit and then power it on restart the whole flash procedure again. You also press any button on front panel about 3 seconds when you power on the

TK-RP08 Unit.

9

Install the TK-RP08 as a Power Control

Accessory for the TK-IP101 Switch

The TK-RP08 can be used as a power control accessory for

TK-IP101 Swtich, or any other KVM Switch that supports a standard serial power control.

and TK-IP101

Trendnet KVM back panel

When used in conjunction with power device or KVM, you have to properly connect the TK-RP08 to the TK-IP101 via a serial interface connection, using the special serial cable that comes with your TK-IP101. Further, you have to correctly configures the setting on the TK-IP101, in order to enable the remote power control function that can be effected via the viewer menu interface on any of the remote connection client computers.

Serial power control cable

(can be found within the TK-

IP101 package)

I. Connect TK-RP08 to TK-IP101

Before you connect the TK-RP08 to the TK-IP101, you might need to install them first into their own proper placements within a rack, that is , if you are going to use them within a rack. After you have installed the TK-RP08, TK-IP101 into the rack, or into their proper locations, you can now proceed with following steps for further connections.

Step 1. Use the serial power control cable that comes with your TK-IP101 package to connect the TK-

RP08 serial interface to the serial port on the backpanel of the TK-IP101.

TK-IP101 back panel

Serial power control cable

(can be found within the TK-

IP101 package)

TK-RP08 Backpanel

Step 2. Make sure that the TK-IP101 and TK-RP08 are powered on. If not, power them up first before proceeding.

Next, you should access the TK-IP101 Web management interface to set up the various power control settings….

II. Enable the Power Control Feature on

TK-IP101 Web Management Interface

Step 3. Access the Web Management Interface of your

TK-IP101.

And from there, you can then go forth to (1) enable the power control feature of TK-IP101, and then (2) configure the

Power control commands for each and every port on the TK-

RP08. (

Also please refer to TK-IP101 User Guide, Section 4.11,

KVM Server/Power Control – Enable the power control.

)….

Step 4. Go to the Power Control page. Then Enable and

Select various Power Control features.

TK-RP08 Backpanel

The Power Control page allows you to enable or disable the power control feature via the serial port on the back panel of your

TK-IP101. (Also please refer toTK-IP101 User Guide, Section 4.11,

KVM Server/Power Control – Enable the power control.)

A real connection case of TK-RP08

10

Configure the Power Control Command for each and every port on the TK-IP101

Step 6. Go to the KVM Server/Computers page.

Step 5. Check the Enabled option to activate the remote power control support feature of the back panel serial port of the TK-IP101.

Once the

Enabled

option is checked, a subsequent

Power Device Login option will appear for you to decide whether to enter the login script. The TK-RP08 does not require a login script. Hence you don’t have to enter any script.

Other options:

Simple Users Can Control Power

Check this box if you want that simple users be able to power on and power off the computers. By default, the TK-IP101 allows only Super admin and admin the right to power on/off the computer from the viewer Quick Menu.

If you want to allow this feature to simpler users, you can check this option.

Power Device Login

Depending on the Serial Power control device you used behind TK-IP101, sometimes you will need a login script to login or initialize your power control device. If that is the case, just check the Power Device Needs a

Login option, and a Login Dialog field will appear for you to enter your login script. In this case, you don’t have to enter any script, since TK-RP08 does not need any.

After you have made all modifications, click Store Settings to save your settings and then hit Apply Settings/Restart

Servers to validate these new settings. Every change you have made on this page will NOT apply until you hit Apply

Settings/Restart Servers!

11

The various settings on this page are KVM port-specific because a computer is first identified by the KVM port it is attached to. Select the target port on which your subsequent settings on this page are directed. You can use the dropdown combo box as well as use the Previous and the Next button to navigate to a specific port.

Important Note:

when using a power control device, please note that some newer computers will require some

BIOS option adjustment to restart when power is coming back. Otherwise they will not restart without a push of the computer power button. Usually, you should enable the

Power Loss Restart

option on your computer BIOS (or similar option depending on the BIOS vendor), so that your computer can boot up when the power control device is feeding power again

.

Step 6-1. Configure the Power down and Power On command for each and every port on the IP KVM Switch.

First, you select the 1 st

port and configure the Power Down and Power Off command, (and if necessary the delay time between the Power Off and Power On Command, or you can leave it as default) then hit the Store Settings buttons. Then, you go the 2 nd

port and then do the configurations likewise, then hit the Store Settings button. …. So you configure every port right through to the last port of your IP KVM switch, and then hit the Store Settings button. Then you hit the Apply Settings button to make the changes effective.

Power down command: /Fbbp\

F: OFF bb: 2-digit bank number on which the target port resides. p: 1-digit target port number. e.g. If you want to turn off port 3 on bank 1. Then you have to enter:

/F013\

Power on command: /Obbp\

O: ON bb: 2-digit bank number on which the target port resides. p: 1-digit target port number.

e.g. If you want to turn on port 3 on bank 1. Then you have to enter:

/O013\

Delay

Here you should specify the delay time between the sending of power-down and power-on commands to complete a power cycling. A power cycling is processed only if you have selected Restart Computer into the Alarm page. By default this delay is 5 seconds.

Important Note: To remotely power on/ off this computer from the Windows or the Java Viewers, switch to this computer and then click

Power On/Power Off automatically by TK-IP101 to the TK-RP08.

in the

Viewer menu. The command specified here will be sent

After you have made all modifications, click Store Settings to save your settings and then hit Apply Settings/Restart Servers to validate these new settings. Every change you have made on this page will

NOT apply until you hit Apply Settings/Restart Servers! (Also refer to TK-IP101 User Guide, Section 4.10, KVM Server/Computers –

Port and IP settings)

Verify the remote Power Control function via Viewer Quick Menu

Step 7. On a client computer that has been installed with the TK-IP101 viewer program, you can then make a viewer connection to the TK-IP101.

For viewer connection details, please refer to Chapter 4, Unit

Management over a secure https browser connection.

Step 7-1. To power off a specific computer, first you have to switch to that computer desktop by clicking its icon in the Select Computer Box to switch to whatever

PC you WAN to perform power on/off from remote.

Step 7-2. Access the Viewer Quick Menu by clicking on the title bar of the viewer window.

Step 7-3. To power on or power off a specific computer desktop of your choice, you need only to select the

Power On /Power Off option on the Viewer Quick Menu.

Now you can use the Viewe Quick Menu to perform power on / power off command remotely across internet by using the TK-IP101 together with an TK-RP08.

Likewise, if you are using any other IP KVM switch that supports serial interface, then you can configure it according to its manual instructions.

12

Serial Command Set

Before you use the serial command …

(1) To use the serial commands for TK-RP08 control, you have to establish a HyperTerminal

connection between

TK-RP08

and the host PC, using a RS-232 cable for connection. Use the following parameters for HyperTerminal connection:

Bits per seconds: 9600

Data bits: 8

Parity: None

Stop bits: 1

Flow Control: Hardware

(2) After your HyperTerminal session has been established, you have to hit the Enter key twice

to go into command mode, then you can input the serial commands within the HyperTerminal

window according to the following command usages ………………

Command usage notes:

1. The commands are NOT case-sensitive. That means you can use lower case in typing your commands! The commands does not require a strict double-digit entry of bank number

or port number (such as ON 01 03 – Power on bank 1 port 3) but can accept their single-

digit entries (such as ON 1 3), and also allow multiple blank spaces in between its

command parameters (such as ON 1 3).

2. When using the HyperTerminal, note that ScrollLock should not be ON. Otherwise, it will block you from entering commands. ScrollLock is OFF by default in HyperTerminal.

However, if you cannot type in commands, please check the ScrollLock status, which can be viewed on status bar at the bottom of your HyperTerminal window. If ScrollLock is ON, hit ScrollLock key again to relieve it.

HELP – Show Help Menu

[Description]Show the Help Menu on the HyperTerminal screen

[Usage] HELP

[Example] Help

? - Show Help Menu

[Description]Show the Help Menu on the HyperTerminal screen

[Usage] ?

[Example]

?

QUIT - Exit serial command mode

[Description] exit serial command mode

[Usage] QUIT

[Example]

QUIT

Notes: Once you exit serial command mode, you have to hit Enter twice again to enter the serial command mode again.

13

ON – Power ON

[Description]Power on one/all AC outlet port(s) immediately

[Usage] ON [bank_number] [port_number]

[Examples]

ON 1 4 – Power on port 4 on bank 1 immediately

ON 1 0 – Power on all ports on bank 1 immediately

ON 0 0 – Power on all ports on all cascaded banks immediately

Notes:

1. A port number of 0 represents all ports; while a bank number of 0 represents all cascaded banks.

2. The command: ON 0 x ………, x = 1~9, is not valid.

OF – Power OFF

[Description]Power off one/all AC outlet port(s) immediately

[Usage] OF [bank_number] [port_number]

[Examples]

OF 1 4 – Power off bank 1 port 4 immediately

OF 1 0 – Power off bank 1 all ports immediately

OF 0 0 – Power off all ports on all cascaded banks immediately

Notes:

1. A port number of 0 represents all ports; while a bank number of 0 represents all cascaded banks.

2. The command: OF 0 x ………, x = 1~9, is not valid.

TA – Timer Activate at specific time point

[Description]Set the timer to turn on/off a specific port

at specific time

[Usage] TA [bank_number] [port_number] [ON | OF] [Time_point]

[Examples]

TA 1 4 ON 01:22:50 – Set timer to power on port 4 on bank 1 exactly at 01:22:50.

TA 1 0 ON 00:10:00 – Set timer to power on all ports on bank 1 exactly at 00:10:00

TA 0 0 OF 01:00:00 – Set timer to power off all ports on all cascaded banks at 01:00:00

Notes:

1. A port number of 0 represents all ports; while a bank number of 0 represents all cascaded banks.

2. The command: TA 0 0x ………, x = 1~9, is not valid.

3. The system time should be calibrated before use for the first time.

TF – Timer Activate after specific time duration

[Description]Set the timer to turn on/off a specific port after specific time duration

[Usage] TF [bank_number] [port_number] [ON | OF] [Time_duration]

[Examples]

TF 1 4 ON 03:25:56 – Set timer to power on port 4 on bank 1 exactly after 3 hour 25 minutes and 56 seconds.

TF 1 0 ON 00:10:00 – Set timer to power on all ports on bank 1 exactly after 10 minutes

TF 0 0 OF 01:00:00 – Set timer to power off all ports on all cascaded banks after 1 hour.

Notes:

1. A port number of 0 represents all ports; while a bank number of 0 represents all cascaded banks.

2. The command: TF 0 0x ………, x = 1~9, is not valid.

14

ED – Timer Activate everyday at a specific time point

[Description]Set the timer to turn on/off a specific port every day at specific time point

[Usage] ED [bank_number] [port_number] [ON | OF] [Time_point]

[Examples]

ED 1 4 ON 02:12:20 – Set timer to power on port 4 on bank 1 exactly every day at 02:12:20.

ED 1 0 ON 00:10:00 – Set timer to power on all ports on bank 1 exactly every day at 00:10:00.

ED 0 0 OF 01:00:00 – Set timer to power off all ports on all cascaded banks every day at 01:00:00.

Notes:

1. A port number of 0 represents all ports; while a bank number of 0 represents all cascaded banks.

2. The command: ED 0 0x ………, x = 1~9, is not valid.

EW – Timer Activate every week at a specific time point

[Description]Set the timer to turn on/off a specific port every week at specific time point

[Usage] EW [bank_number] [port_number] [ON | OF] [day] [Time_point]

[Examples]

EW 1 4 ON 1 01:22:50 – Set timer to power on port 4 on bank 1 exactly every Monday at 01:22:50..

EW 1 0 ON 3 00:10:00 – Set timer to power on all ports on bank 1 exactly every Wednesday at 00:10:00.

EW 0 0 OF 5 01:00:00 – Set timer to power off all ports on all cascaded banks every Friday at 01:00:00.

Notes:

1. A port number of 0 represents all ports; while a bank number of 0 represents all cascaded banks.

2. The command: EW 0 0x ………, x = 1~9, is not valid.

3. A day of 0 represents Sunday; while a day of 1 represents Monday, later calculate for this reason.

TQ – Timer Quit

[Description]Cancel a specific/all timer setting(s)

[Usage] TQ [bank_number] [port_number] [ON | OF]

[Examples]

TQ 1 4 ON – Cancel timer power-on setting on port 4 of bank 1

TQ 1 4 ON – Cancel timer power-on setting on port 4 of bank 1

TQ 0 4 - Cancel timer power-on&off setting on port 4 of bank 1

TQ 1 0 OF - Cancel timer power-off setting on all port of bank 1

TQ 0 0 ON - Cancel timer power-on setting on all port of all banks

TQ 0 0 - Cancel timer power-on&off setting on all port of all banks

Notes:

1. A port number of 0 represents all ports; while a bank number of 00 represents all cascaded banks.

2. The command: TQ 0 x ………, x = 1~9, is not valid.

3. If you have not specified either “ON” or “OF” as the command parameter, it is assumed that this Timer Quit directive will be directed on both the Power-ON and Power-

OFF setting of that specific port.

15

ST – Status

[Description]Show the system status of a specific bank, such as current loads, on/off status and timer settings

[Usage] ST [bank_number]

[Examples]

ST 1 – Show the system status of bank 1

ST 16 – Show the system status of bank 16

ST 0 – Show the system status of all banks

UPGRADE – Upgrade Firmware

[Description]Upgrade the system firmware

[Usage] UPGRADE

[Example]

UPGRADE

Note: Please also refer to ioPower Flash Operation Guide for details.

SETTIME – Set Up System Date and Time

[Description]Set up the system date and time

[Usage] SETTIME [20yy/mm/dd] [hh:mm:ss]

[Example]

SETTIME 2004/09/27 18:10:00 – Set up the system Date and time to be 2004/09/27 18:10:00

GETTIME – Get System Time

[Description]Show the system date, day and time

[Usage] GETTIME

[Example]

GETTIME

VER – Firmware Version

[Description]Show the firmware version of a specific bank.

[Usage] VER [bank_number]

[Example]

VER 01 – Show the firmware version of bank 1

VER 16 – Show the firmware version of bank 16

VER 00 – Show the firmware version of all bank

16

17

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement