SCBA Pre-production images and information provided, production model may vary.

SCBA Pre-production images and information provided, production model may vary.
MSA G1 SCBA
Pre-production images and information provided, production model may vary.
MSA G1 SCBA
A Timeline of Innovation
At MSA, “When you go in…We go in with you” is more than just words, it’s what drives us.
Everything we do is done with your safety and comfort in mind. When we create our products,
we’re guided by a single question: How do we meet and exceed our customers’ safety needs?
In answer, we solicited feedback from firefighters across the nation, we listened closely and we
incorporated those ideas to produce the most advanced, intelligent user-friendly
self-contained breathing apparatus (SCBA) available today.
1917: MSA enters breathing apparatus market with
Gibbs & Mcaa closed-circuit apparatus for rescue &
firefighting.
1936: First firefighting breathing apparatus –
MSA Lightweight Half-Hour OBA.
1954: Bureau of Mines approved Demand Air Mask
for air or oxygen.
1967: MSA introduces Belt-Mounted Regulator
SCBA, Model 401.
1980: Ultralite fully-wrapped cylinder launched.
Introducing the MSA G1 SCBA: The most comfortable, streamlined, balanced,
configurable, and customizable SCBA we’ve ever produced.
1983: Custom 4500® Air Mask - MSA’s first high
pressure SCBA.
1985: Nomex SCBA shoulder straps introduced; all
Nomex Flame & Heat Resistant (FHR) SCBA harness.
Our Commitment to the Fire Service
MSA’s long-standing commitment to the
fire service began nearly 100 years ago.
Our continuous goal has been to provide
dependable, high-quality personal
protective equipment, instruments and
service to help to ensure a safe return home.
MSA’s extensive knowledge and expertise
has helped to harness new technologies to
produce exceptional protective equipment.
The MSA G1 SCBA offers integrated and
enhanced solutions to exceed your needs
today as well as years into the future.
“MSA has taken all of the firefighters’ concerns
and addressed them in the MSA G1 SCBA.”
– TB, Firefighter
1987: First breathing apparatus to meet NFPA 1981
Edition fire service standards – Ultralight II & Custom
4500 II. Revolutionary Quick-Fill® System allows
firefighters to replenish air supply; becomes
requirement on all NFPA SCBA in 2002. ClearComTM
RI Communications System integrates facepiece
mic with radio.
1990: Ultralite® MMR and Custom
4500 MMR Air Masks introduced.
Composite III Cylinder can be
pressurized to 3000 psig.
1992: FireFly® PASS System.
1994: Ultra Elite® Facepiece launched.
1999: MMR Xtreme® SCBA offers new levels of
performance. Vulcan Carrier & Harness is first
composite-molded SCBA back frame. DragonFly® PASS
is offered in stand-alone or integrated versions.
2000: Integrated Control Module (ICM).
2002: FireHawk® Air Mask, first unit certified to new
NFPA 1981, 2002 Edition standard that includes CBRN
component and Quick-Fill System.
2007: FireHawk M7 - First SCBA compliant to NFPA
1981 & 1982, 2007 Edition.
2013: FireHawk M7XT Air Mask.
2014: MSA G1 SCBA.
www.MSAFire.com
3
The MSA G1 SCBA stands out from the crowd.
6. MSA G1 SCBA ergonomics
• Swiveling, adjustable lumbar pad
manages SCBA weight
• Improved comfort, balance, fit
1. G1 Facepiece is lightweight and compact:
No electronics needed
• Open port design with cross contamination protection
• Comfortable and easy to use,
with low breathing resistance on and off air
2. Control Module provides both color LCD
and analog displays
• Display automatically turns on when
control module is lifted into viewing position
• Large print makes display easy to read
• Provides more data and functionality than ever before
• No matter which button is pressed,
necessary information displays
3. Improved visibility through buddy lights
and reflective material
• 4 buddy lights located on the backplate
• 2 control module lights
• Regulator light
q
r
8. Available in easily-upgradeable threaded
or quick-connect cylinder attachment
• Quick attachment and replacement
for return to the fireground
Integrated technology for future expansion
• Bluetooth, RFID, Near Field Communication
(NFC), long-range radio
e
Customizable — Built to meet your
specific needs
• Control module and HUD display required
information; easily adapt to your existing
standard operating procedure
• Wires/hoses can be routed as necessary
t
4. Heads up display (HUD) shows
remaining cylinder pressure
in 4 increments via colored LEDs
• Clear and easy to understand
and interpret provided information
5. Electronic communications
are integrated into every unit
• Loud, clear communication
• Removes inhalation
breathing noise
7. Central power system for all electronics
• Only one power source
• Uses either alkaline or rechargeable battery
• No need for multiple battery sizes
• Low cost of ownership
w
u
y
e
5
i
www.MSAFire.com
MSA G1 SCBA Components
MSA G1 SCBA Components
About FACE.
Designed to fit YOUR needs.
The G1 Facepiece was designed without electronic components, to
minimize weight, reduce your stress and fatigue and improve your
overall performance level. This design also means that there are no
electronic components on the outside of the facepiece that may
result in snag and entanglement hazards. What’s more, by
eliminating costly electronic components, the price is reduced
substantially, allowing personal-issue facepieces to be a cost
effective measure. As an added bonus, the facepiece is equipped
with cross-contamination prevention to reduce the spread of
illness when facepieces are shared. But MSA didn’t stop there. The
MSA G1 SCBA is also equipped with a speaking diaphragm to
increase speech clarity while off air.
Cutting edge technology. The MSA G1 SCBA has been designed
to meet and exceed your demands, providing more functionality
than ever before. The G1 Control Module has both analog and color
digital LCD displays, making certain that your status is available at
all times. Auto-start motion control mechanism built into the
control module intuitively provides the information you need
when you need it. Adding yet another layer to ease-of-use: no
matter which button is pressed, your information displays.
Highly configurable and customizable. The MSA G1 SCBA’s user
selectable configurations are an industry first: pressure; time
remaining calculation; breathing time; temperature (the ability to
set your own temperature alarm); and pressure drop (to alert you
to leaks, either primary or secondary). What’s more, the control
module and HUD can be programmed to display information
required by your particular specification. But best of all, electronics
can be adjusted to the way YOU want. The MSA G1 SCBA provides
the ability to configure this device to follow any standard operating
procedure, with alarm settings, lights and information provided on
the control module. The MSA G1 SCBA…designed for the flexibility
you need!
The new G1 Facepiece is not only lightweight and compact with
overall low profile design, it’s comfortable and built to last. Taking
the preferred design features of the Ultra Elite Facepiece, including
wide field of view and comfortable, robust seal geometry, we’ve
taken the MSA G1 SCBA to the next level with an open port to
provide low breathing resistance, both on and off air.
The G1 Facepiece can help you to conserve energy for when you
need it most.
Be Heard.
Electronic Voice Amplification Shouldn’t Be Optional.
Every MSA G1 SCBA is equipped with electronic voice amplification
because high quality fireground communications shouldn't be
optional. With patent-pending design, dual microphones
integrated into the regulator eliminate the Darth Vader-like
inhalation sound. This unique feature automatically activates and
shuts down with the unit. Shoulder strap-mounted speaker
module provides loud and clear communications from the
regulator microphone while maintaining low profile to aid in
reducing snag points. Every MSA G1 SCBA is equipped with this
cutting edge technology.
Heads up.
Internal HUD display. No facepiece electronics? It’s not only
possible, it’s here. By placing electronics that power the Heads Up
Display within the regulator, MSA has effectively reduced weight,
profile, pairing, and cross talk. The HUD is inside the facepiece, so
external contaminants cannot block the view and vital displayed
relayed information. This new design means that you no longer
have to buy HUDs for each facepiece, reducing costs and
maintenance. By using revolutionary light pipes, the MSA G1 SCBA
heads up display is clear and simple to understand; it’s a HUD
system made easy!
7
www.MSAFire.com
MSA G1 SCBA Components
MSA G1 SCBA Components
Always in Demand.
The Power of One.
G1 Mask-Mounted Regulator. The G1 Regulator houses easy-tooperate heads up display and communications, yet is the smallest
and lightest regulator available. The G1 Regulator has an optional
purge cover that can be used to start air flow during emergency
situations. The G1 Regulator can also be shut off and removed from
the mask with one simple action!
Central Power System. With only one centralized power source,
you can use either alkaline or an industry first rechargeable
battery. As the ONLY manufacturer to offer rechargeable batteries,
we’ve taken SCBA protection to a whole new level — finally, an
SCBA that doesn’t require multiple battery sizes! No need to
manage battery types, compartments and change-outs, resulting
in lower cost of ownership.
The G1 Regulator is always in DEMAND!
Make a Connection.
Finally, an SCBA where one size really can fit all.
Pressure Reducer. Designed to work with quick connect or
CGA threaded cylinders, there’s a connection to meet your need.
Adding to this flexibility are available direct and remote quickconnect attachment options to enable effortless cylinder
change-outs. Pressure reducer accessory ports allow for future
upgrades, including the high pressure Quick Fill® System.
The MSA G1 SCBA is available in both quick-connect and threadedconnection options. With minimal parts, you can easily upgrade
from one option to the other! All in all, this unit provides each user
with many choices, all of which result in lower cost of ownership.
Ergonomics. The MSA G1 SCBA is the only SCBA on the market
that offers harness customization to ensure improved comfort,
balance and fit. By providing an adjustable lumbar pad, you can
have a tailored unit with up/down and pivot capabilities that can
actually move with you. Widened, adjustable shoulder straps
enhance weight distribution and comfort. Through use of
interlocking shoulder straps and strategically placed friction pads,
the MSA G1 SCBA provides increased fit and
stability while allowing for easy donning
and doffing. The G1 Control Module,
G1 Regulator and G1 Speaker Module
can be configured on either
shoulder, easily integrating
into any standard operating
procedure.
When Air is Low, Seconds Matter.
Universal Air Connection (UAC). When air is low and you must
access the UAC for emergency purposes, seconds matter. That’s
why MSA invented the patent-pending RIT light to shine a bright
white LED on the UAC connection, making it easier to find and
connect to a rescue air source. The primary UAC illuminates when
End of Service Time Indicator (EOSTI) reaches 35%.
9
www.MSAFire.com
MSA G1 SCBA Accessories
MSA G1 SCBA Accessories
The Quick-Fill System
MSA G1 SCBA Accessories
The Quick-Fill System lets MSA air mask users refill and transfill air
cylinders while SCBA is worn, without removing air cylinder —
even in IDLH atmospheres. Use this MSA option to:
• Fill SCBA cylinder from mobile compressor or cascade system
in less than a minute.
• Transfill between two cylinders, providing emergency
breathing system.
• Extend air supply over longer durations, using remote
compressed-air source.
Air masks compliant to recent NFPA standards have Quick-Fill URC
fitting located at the Audi-Larm™ Audible Alarm warning device.
Quick-Fill System hose with quick-disconnect connects air source
to adapter for air transfer. See Bulletin 0105-92-MC for a Quick-Fill
System Q&A.
Ordering Information
QUICK-FILL SYSTEM
REPLACEMENT
PARTS
10156464
ExtendAire II Kit for MSA G1 SCBA
10156465
Waist Mounted Quick-Fill for MSA G1 SCBA
10156466-SP
Replacement ExtendAire II Pouch for MSA G1 SCBA
10156467-SP
Replacement Quick-Fill Pouch for MSA G1 SCBA
10156468
3 ft Quick-Fill hose in pouch for MSA G1 SCBA
25 ft
QUICK-FILL
HOSES
12 ft
10 ft
8 ft
6 ft
Part Number
Description
10148740-SP
Replacement Alkaline Battery Pack
10148741-SP
Replacement Rechargeable Battery Pack
10158385
Rechargeable Battery Charging Station
10149701-SP
Quick Connect Adapter for 2216 psig Cylinders
10149702-SP
Quick Connect Adapter for 4500/5500 psig Cylinders
10158389
Retainer Kit for H-30 Carbon (807587) 4500 psig (Type 2 - dovetail)
10158390
Retainer Kit for H-45 LP Carbon (10035644) 4500 psig (Type 3 - dovetail)
10158401
Retainer Kit for L-30 Carbon (807586) 2216 psig (Type 4 - dovetail)
10158401
Retainer Kit for H-45 Carbon (807570) 4500 psig (Type 4 - dovetail)
10158402
Retainer Kit for H-60 Carbon (807588) 4500 psig (Type 5 - dovetail)
10158408
Quick Connect Adapter for Fill Station
10158403
Tool Kit (M7 P.N 10120427)
10158409
G1 Flow Test Adapter
10083875
RFID (M7 P.N 10083875)
10158407
RFID Reader/Writer (M7 P.N 10083876)
3 ft
485332
802690
802689
802688
802687
485331
FQD x FQD
487907
802677
802675
802673
802671
492796
FQD x CGA-347 Outlet
487909
802685
802683
802681
802679
487427
FQD x CGA-347 CN
487906
802704
802703
802702
802701
802705
FQD x SAE-4
487908
802678
802676
802674
802672
492797
FQD x CGA-346 Outlet
487910
802686
802684
802682
802680
487428
FQD x CGA-346 CN
25-ft lengths are stocked; other custom lengths are available on special material basis. All SAE fittings are for high-pressure service. Female quick-disconnect fittings have dust covers.
11
Spectacle Kit for G1 Facepiece
We have taken the old and outdated spectacle kits of the past
and thrown them in the trash. Working with TriSpec, MSA has
designed a modern and sophisticated option, providing both
clear sight and style.
Part Number
10144230
Description
Spectacle Kit for G1 Facepiece
www.MSAFire.com
MSA G1 SCBA Cylinders
MSA G1 SCBA Facepieces and Accessories
MSA G1 SCBA Cylinders for Remote Connection
MSA G1 SCBA Facepieces
Cylinder Pressure
Cylinder Duration
Connection Type
Air
Less Air
2216 psig
30 min
Remote
10156422-SP
10156431-SP
4500 psig
30 min
Remote
10156423-SP
10156432-SP
4500 psig
45 min LP*
Remote
10156424-SP
10156433-SP
4500 psig
45 min
Remote
10156425-SP
10156434-SP
4500 psig
60 min
Remote
10156426-SP
10156435-SP
Part Number
Type
Size
Nosecup Size
Head Harness
ATO Configuration
10156458
Fire Service
Small
Small
4 pt adjustable
G1FP-F-S-1-S-4-0-1
10156459
Fire Service
Medium
Medium
4 pt adjustable
G1FP-F-M-1-M-4-0-1
10156460
Fire Service
Large
Large
4 pt adjustable
G1FP-F-L-1-L-4-0-1
10156461
Fire Service
Small
Small
Rubber
G1FP-F-S-1-S-R-0-1
10156462
Fire Service
Medium
Medium
Rubber
G1FP-F-M-1-M-R-0-1
10156463
Fire Service
Large
Large
Rubber
G1FP-F-L-1-L-R-0-1
PLEASE NOTE: Quick Connect Cylinder Adapter must be ordered for each cylinder separately.
Quick Connect Cylinder Adapter part numbers for: 2216 PSI = 10149701-SP; 4500/5500 PSI = 10149702-SP.
* Low Profile version of the 45 min, 4500 psig cylinder
MSA G1 SCBA Facepiece Accessories
MSA G1 SCBA Cylinders for Direct Connection
Cylinder Pressure
2216 psig
Cylinder Duration
30 min
Connection Type
Direct
Part Number
Air
10156440-SP
Less Air
10156449-SP
4500 psig
30 min
Direct
10156441-SP
10156450-SP
4500 psig
45 min LP*
Direct
10156442-SP
10156451-SP
4500 psig
45 min
Direct
10156443-SP
10156452-SP
4500 psig
60 min
Direct
10156444-SP
10156453-SP
10144230
Spectacle Kit for G1 Facepiece
10144220-SP
Replacement Cloth Neck Strap
10159699-SP
Replacement Rubber Neck Strap
10144231-SP
Filter Adapter Assembly
805078
QuikChek Adapter
Assemble-To-Order System for MSA G1 SCBA Facepiece
PLEASE NOTE: Quick Connect Cylinder Adapter must be ordered for each cylinder separately.
Quick Connect Cylinder Adapter part numbers for: 2216 PSI = 10149701-SP; 4500/5500 PSI = 10149702-SP.
* Low Profile version of the 45 min, 4500 psig cylinder
A
B
C
D
E
F
G
Application
Size
Material
Nosecup
Head Harness
Neckstrap
Regulator Connection
F Fire
MSA G1 SCBA Cylinders for 5500 psig system
Description
S Small
1 Hycar
M Medium
Cylinder Pressure
Cylinder Duration
Connection Type
Air
Less Air
L Large
0 None
0 None
0 None
S Small
4 4 pt Adjustable
C Cloth
M Medium
5 5 pt Adjustable
R Rubber
L Large
5500 psig
30 min
Remote
10156427-SP
10156436-SP
5500 psig
45 min
Remote
10156428-SP
10156437-SP
5500 psig
60 min
Remote
10156429-SP
10156438-SP
5500 psig
75 min
Remote
10156430-SP
10156439-SP
5500 psig
30 min
Direct
10156445-SP
10156454-SP
5500 psig
45 min
Direct
10156446-SP
10156455-SP
5500 psig
60 min
Direct
10156447-SP
10156456-SP
5500 psig
75 min
Direct
10156448-SP
10156457-SP
NOTE: Part number facepieces are also available.
* Available in January 2015
Column:
G1FP
A
F
B
C
1 Fixed Push-toConnect
R Rubber*
D
E
F
1
PART NUMBERS (BOLD LEFT HAND COLUMNS)
G
13
1
QUANTITY
PLEASE NOTE: Quick Connect Cylinder Adapter must be ordered for each cylinder separately.
Quick Connect Cylinder Adapter part numbers for: 2216 PSI = 10149701-SP; 4500/5500 PSI = 10149702-SP.
www.MSAFire.com
MSA G1 SCBA Assemble-To-Order-System
A
B
C
D
E
F
G
H
J
K
L
System
Pressure
Cylinder
Connection
Harness
Cradle Type
Lumbar Type
Regulator Type
Regulator Hose Type
Emergency Breathing
Support
Speaker Module
PASS
Battery Type
C Continuous
0 None
L Left Chest †
A PASS Right Shoulder †
A Alkaline
Q Quick-Connect
1 Waist Mounted
Quick-Fill~
R Right Chest †
B PASS Left Shoulder †
R Rechargeable*
2 2216 psig
1 CGA Threaded
Direct
Connection~
4 4500 psig
1 Standard without
Chest Strap
B Basic
F Fabric Band~
2 CGA Threaded
Remote Connection
5 5500 psig *
M Metal Band
3 CGA Quick Connect
Direct Connection~
4 CGA Quick Connect
Remote Connection
1 Purge cover
Left Shoulder †
F Fixed Swiveling
Lumbar Pad
2 Standard with Chest
Strap
2 Solid cover
Left Shoulder †
A Adjustable Swiveling
Lumbar Pad
3 Serviceable Tunnel
without Chest Strap
1 Rescue Belt II
50' Hook*
4 Serviceable Tunnel
with Chest Strap
2 ExtendAire II^
3 Purge cover
Right Shoulder †
4 Solid cover
Right Shoulder †
3 Waist Mounted
Quick-Fill and
ExtendAire II~
C PASS Telemetry
Right Shoulder †
D PASS Telemetry
Left Shoulder †
2 Rescue Belt II
50' Carabiner*
3 Rescue Belt II
50' FireTech Rope,
Hook*
If 1 or 3 are selected,
fabric band must be used.
4 Rescue Belt II,
50' FireTech Rope,
Carabiner*
† As worn
^ Available Spring 2015
* Available Summer 2015
~ Available Fall 2015
Column:
A
B
C
D
E
F
G
H
J
K
L
G1FS
PART NUMBERS (BOLD LEFT HAND COLUMNS)
QUANTITY
15
www.MSAFire.com
MSA—The Safety Company
Our business is safety. We’ve been the world's leading manufacturer of
high-quality safety products since 1914. MSA products may be simple to
use and maintain, but they’re also highly-sophisticated devices and
protective gear — the result of countless R&D hours, relentless testing,
and an unwavering commitment to quality that saves lives and protects
thousands of men and women each and every day. Many of our most
popular products integrate multiple combinations of electronics,
mechanical systems, and advanced materials to ensure that users around
the world remain protected in even the most hazardous of situations.
Our Mission
MSA’s mission is to see to it that men and women may work in safety and that they,
their families, and their communities may live in health throughout the world.
Note: This bulletin contains only a general
description of the products shown. While uses
and performance capabilities are described,
under no circumstances shall the products be
used by untrained or unqualified individuals
and not until the product instructions
including any warnings or cautions provided
have been thoroughly read and understood.
Only they contain the complete
and detailed information
concerning proper use and
care of these products.
MSA – The Safety Company
1000 Cranberry Woods Drive
Cranberry Township, PA 16066 USA
Phone 724-776-8600
www.MSAFire.com
U.S. Customer Service Center
Phone 1-877-MSA-FIRE
Fax
1-877-672-3930
MSA Mexico
Phone 1-877-672-3473
Fax
011 52 55 5359 4330
MSA International
Phone 724-776-8626
Toll Free 1-800-672-7777
Fax
724-741-1553
Email
[email protected]
MSA Canada
Phone 1-877-MSA-FIRE
Fax
1-800-967-0398
ID 0105-169-MC / Apr 2015
© MSA 2015 Printed in U.S.A.
www.MSAsafety.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement