ADVANCE SmartSeries - GAI

ADVANCE SmartSeries - GAI
When faced with the responsibility of upgrading your plant communication system...or
with the task of designing or recommending an Emergency Notification System for your
facility...GAI-Tronics ADVANCE / SmartSeries™ systems offer a smart solution.
After 60 years’ experience in producing rugged and reliable communications systems for
industrial and hazardous environments, GAI-Tronics knows what it takes to keep a
communication system running smoothly. We used this experience in designing the
microprocessor-based ADVANCE / SmartSeries™ System, the intelligent way to address
all of your communication, supervision, and notification needs.
ADVANCE / SmartSeries™ systems are fully adaptable to a variety of facility sizes, from a
few handsets to several hundred. Using SmartLink technology, multiple independent
communication systems can be interfaced and monitored from a central location.
The same features that improve operational communications assume even greater
significance in an Emergency Notification System:
n
Broadcast of up to 100 alarm tones and pre-recorded speech messages, all custom configured.
n
The ID feature identifies the specific station generating a page, so that control room personnel
can locate the source of the emergency.
n
The Emergency Party Line feature automatically connects the SmartSeries station to the
Control Room, as well as identifying the specific station, to locate the source of the emergency.
n
The Priority Page feature allows a control room operator to override operational communication
to issue priority pages to emergency response personnel, or to issue live updates to the emergency
situation.
n
The SmartStatus feature provides a graphical user interface to the system, allowing quick
location of emergency pages or reports. SmartView Portal provides a graphical representation of
the facility and communication system.
n
GAI-Tronics’ SmartVolume technology ensures that even in the presence of high ambient noise
levels, employees will hear important emergency announcements.
n
Auxiliary Input/Output features allows alarm initiation and auxiliary device activation from the
field stations.
ADVANCE / SmartSeries™ system field
devices utilize the latest technology in
data communications to significantly
improve system integrity and functionality.
By interfacing with the ADVANCE control unit, the devices exchange fault and activity messages. The SmartView Portal provides a graphical display of the entire communication system, making the system very user-friendly.
Current faults are displayed or logged, depending on the system configuration, to provide
maintenance personnel a means to diagnose equipment problems. For example, a handset
left off-hook can degrade an audio channel. To alleviate this problem, the stations report
this condition and are programmed to go electronically on-hook after a pre-set time period
configured at start up.
Other system functions monitored by the control unit include use of the page line, integrity
of the system cable, and the functionality of the station amplifier and associated speakers.
Supervision of these features significantly reduces the costs associated with maintaining
your communication system.
With emergency notification as a major industrial concern, GAI-Tronics offers the ADVANCE
Emergency Notification System. The ADVANCE Control Unit interfaces with GAI-Tronics
standard Page/Party® or SmartSeries™ stations to provide all of the features required for an
Emergency Notification System that you and your employees can depend on.
ADVANCE SmartSeries™
Indoor/Outdoor Stations
n Station off-hook status monitored
n Page and off-hook duration
limited to prevent nuisance pages
and open microphone problems
n SmartVolume feature automatically
adjusts station speaker volume
according to background noise
Desktop Station
Outdoor and
Explosionproof Station
n Self-diagnostics monitor status
and report problems with speaker
amplifier, speaker voice coil, cable
path, and handset amplifier
n Priority page allows important
messages to override operational
communications. Different priorities
are available for normal and alarm
modes
n Hazardous Area Approvals
- UL/cUL (Division 1 and Division 2)
- ATEX (Zone 1)
Indoor Speaker Amplifier
Outdoor Station
Indoor/Outdoor Handset Stations and Speaker Amplifiers
SmartSeries™ Indoor/Outdoor Handset Stations offer communication and monitoring features for use in the
GAI-Tronics SmartSeries™ System. The stations interface with the SmartSeries™ Control Unit, exchanging
information including station health check and the status of the associated speaker. These stations are
equipped with GAI-Tronics’ SmartVolume feature to automatically adjust speaker volume by measuring
ambient noise levels.
Indoor/Outdoor Stations with RTU
The SmartSeries™ Remote Terminal Unit (RTU) Station provides the added benefit of interfacing with the
SmartSeries™ Control Unit to monitor inputs such as pullboxes or smoke detectors, and activate outputs
such as strobes. A typical installation allows the user to initiate alarms or signal equipment starts by pressing
a remotely located pushbutton (up to twenty feet from the enclosure). The system recognizes the input and
proceeds as configured by the system software.
Indoor/Outdoor Stations with Emergency Party Line
SmartSeries™ Indoor/Outdoor Emergency Party Line stations are designed especially for use in emergency
notification systems. The stations interface with the SmartSeries™ Control Unit, exchanging information
including station off-hook status, page detection, and station health check. The Emergency Party Line
stations offer the added benefit of reporting use of Party Lines #1 and #2. This feature is essential when
reporting life critical events or for providing hot-line service to a central command center.
GAI-TRONICS® A Hubbell Company
Toll Free: 1-800-492-1212
Tel: 610-777-1374
FAX: 610-796-5954
www.gai-tronics.com
ADVANCE SmartSeries™
Master Control Unit (MCU)
The Master Control Unit (MCU), the central processing component of the
SmartSeries™ system, coordinates and processes all system functions.
Pre-loaded with system software, the MCU includes system configuration
information stored on a solid state disk. During start-up, the MCU executes
all system operations based on the programmed configuration.
The MCU maintains constant communication with the Card Rack interface
assemblies through an ISA PC style bus structure. Static conditions (e.g.,
Page/Party® Interface line in-use status) are monitored by the MCU through
this mechanism. Data communications to field devices are supported by this
mechanism and the specialized data port of each interface.
External Audio Interface (EAI)
Audio Messenger Interface (AMI)
The External Audio Interface (EAI) allows multiple audio paths to be interfaced
to a SmartSeries™ system. The EAI works in concert with the Audio Messenger
Interface (AMI) to route alarms and pre-recorded speech messages. The EAI
supports 4 external audio inputs; two are dedicated for use by the AMI whereas
the other two can be independently configured. Additionally, the EAI provides 2
audio outputs . The EAI contains a 1.00 kHz sine wave detector for use in the
supervision of several internal audio paths.
The Audio Messenger Interface (AMI) provides pre-recorded
alarm tones, pre-recorded speech messages. The tones include
typical emergency tones (i.e., a siren, slow whoop, etc.) and
signaling or process tones (i.e., a gong, steady tone, etc.).
All of the tones and speech messages broadcast by the AMI
are stored in MP3 file format. For applications where
a needed tone is not supplied, any tone
recorded or stored in an MP3 file format can
be used with the AMI. The telephone interface
option allows users to access the SmartSeries™
system for page and party line communication through
a telephone.
GAI-TRONICS® A Hubbell Company
Toll Free: 1-800-492-1212
Tel: 610-777-1374
FAX: 610-796-5954
www.gai-tronics.com
ADVANCE SmartSeries™
SmartView/Portal Graphical User Interface
Standard SmartSeries™ systems provide a printout of equipment and system status. Customers who prefer a flexible PC
platform utilize the SmartView/Portal Graphical User Interface.
Via a dedicated PC, SmartView/Portal provides an interactive
tool for monitoring system and equipment status in real-time
Use of this feature requires a dedicated PC
for the Portal Server application.
SmartLink Network Connection
Larger facilities with many communication points frequently use multiple SmartSeries™
Control Units. These customers benefit from the use of our SmartLink technology because the systems can be combined for page and party line communication, and for the
exchange of system status data.
Use of this feature requires a Voice Network Adapter Interface Card and an Ethernet card
connection to each MCU card.
Smart Service
GAI-Tronics offers system support agreements in four flexible coverage plans designed to
meet the facility needs. Key features of these plans are:
• 24 Hour Telephone Support
• On-Site Emergency Support
• Advance Replacement of Critical Spares
• System Support and Maintenance Training for Quick Restore
• Software Support
Our Services Bring Peace of Mind
GAI-TRONICS® A Hubbell Company
Toll Free: 1-800-492-1212
Tel: 610-777-1374
FAX: 610-796-5954
www.gai-tronics.com
ADVANCE SmartSeries™
Access Panels
Access Panels provide an operator interface for alarm control,
speech communications and system status monitoring.
Four models of Access Panels address a variety of customer
requirements.
Console models include an integral display, handset and
programmable switch/lamp array. Rear connections are
available for remote amplified speaker and sounder
attachments. These models are available with a 28 button
configuration. Desktop models include a handset, integral
speaker and 28 programmable switch/lamp elements.
The handset supports paging and/or party line communications as determined by the system configuration. Models
with a display include an LCD screen, acknowledge switch
sounder and lamp, and previous switch. The VFD allows
operator review of textual system status messages including
system alarm initiation, faults and operation information. A
sounder and lamp alert the operator of system status changes.
Access Panel Interface Card (API)
The Access Panel Interface (API) supports the deployment of eight customer configured Access
Panels. These panels provide operator-machine interface for SmartSeries system alarm, page, party
and status operations.
The Master Control Unit (MCU) interrogates and establishes audio connections for each of the eight
(8) Access Panels through each API. The line connection to the panel is one twisted pair. This line
supports one-way speaker output audio (page output), two-way handset audio (page and party),
and data communications.
Each API provides digital switching, conferencing and conversion capabilities to support one
analog and four digital party lines, and two analog page lines. The API page and party lines connect
to the Card Rack resources.
GAI-TRONICS® A Hubbell Company
Toll Free: 1-800-492-1212
Tel: 610-777-1374
FAX: 610-796-5954
www.gai-tronics.com
ADVANCE SmartSeries™
Monitored Relay Module (MRM)
Monitored Input Module (MIM)
Amplifier Distribution Module (ADM)
The Monitored Relay Module (MRM) controls relays typically used
for alarm notification, such as strobe lights to supplement alarm
broadcasts. The MRM supports line supervision to the notification
appliance when it is not in use.
The MRM is capable of supplying and supervising eight (8) relay circuits. Any outputs that are not utilized may be configured for use as
an alarm initiation input. Each line may be configured independently
for its intended use. All lines are supervised for open circuits and
ground faults. Indication and single device configurations monitor
short circuit conditions.
The Monitored Input Module (MIM) interrogates switch status
changes for an alarm initiation request or various line fault conditions.
The MIM is capable of supervising eight (8) alarm initiating lines for
such use as alarm pull box loops. Each line may be configured
independently to monitor single or multiple switch activation or
deactivated if not used. All lines are supervised for open circuits and
ground faults. The single device configuration monitors short circuit
conditions.
The Amplifier Distribution Monitor/Module (ADM) distributes the
audio level to amplifiers and monitors the return speaker loop
integrity and amplifier fault status condition. The ADM is used to
distribute audio to up to six central amplifiers. The ADM also verifies
the integrity of the related speaker loops and monitors up to six
amplifier failure contacts, reporting their status to the MCU.
The ADM’s speaker loop inputs detect various fault conditions on up
to six speaker loops. These fault conditions include ground faults,
cable breaks and wire-to-wire short circuits (while associated amplifier
is not in use), and amplifier failures.
The ADM’s contact closure inputs are typically used to monitor the
contacts of the central amplifiers to determine amplifier failure.
GAI-TRONICS® A Hubbell Company
Toll Free: 1-800-492-1212
Tel: 610-777-1374
FAX: 610-796-5954
www.gai-tronics.com
ADVANCE SmartSeries™
Dual Page/Party® Interface (PPI)
The Dual Page/Party® Interface (PPI) is used to route audio to Page/Party®
and SmartSeries™ field equipment connected to a Page/Party® system cable
with interrogation for up to 400 SmartSeries™ devices and/or numerous
Page/Party® stations in 2 zones. A data communications port supports
interrogation of the addressable devices by the Master Control Unit (MCU).
System page operation to/from the Page/Party® area is sequenced by the
MCU through use of the Card Rack Assembly page resources. The internal
page audio path is supervised when not in use. Two Card Rack party line
connections support MCU system merge/isolate party operations. The
corresponding Page/Party® party lines are monitored for in-use status.
The Dual PPI monitors the Page/Party® page line and one party line for faults
that degrade audio quality. Faults may be attributed to continuity to ground,
wire-to-wire shorts or open circuit conditions. Detection of short or open
conditions require a SmartSeries™ station to be placed at the end of each
circuit branch.
Amplifier Zone Interface (AZI)
The Amplifier Zone Interface (AZI) is used to route Card Rack page audio
to twelve power amplifiers. These amplifiers may feed from one to twelve
speaker-loops.
The AZI supports Master Control Unit (MCU) selection of any of the 12
audio outputs for three simultaneous page operations: two page broadcasts and audio supervision. Two output level settings are provided for
normal or emergency page broadcasts. In addition, the interface supports
ten MIMs, MRMs or ADMs through a data communications port. These
devices are interrogated by the MCU.
Supervision of any amplifier audio path requires the use of one or more
Amplifier Distribution/Monitor Modules (ADM). To test the systems’
amplifier and speaker loop integrity a high frequency inaudible test tone is
routed to the amplifier and associated speaker-loops when the circuit is
not in use. The ADM monitors the return path for faults that degrade
audio quality. Faults may be attributed to continuity to ground, wire-towire shorts or open circuit conditions.
GAI-TRONICS® A Hubbell Company
Toll Free: 1-800-492-1212
Tel: 610-777-1374
FAX: 610-796-5954
www.gai-tronics.com
ADVANCE SmartSeries™
Model and Part Numbers
Order
Model
No.
Desktop,
Desk-edge
and
Flush-Mount
Stations
Subset
723-901
7245-004
726-101
726-912**
723-905
7245-005
726-101
7265-802
723-901
7245-004
7265-101
7265-912**
723-905
7245-005
7265-101
710-804
723-901
7245-004
711-102
7105-804
723-901
7245-004
7115-102
715-804
723-901
7245-004
716-102
7155-804
723-901
7245-004
7165-102
821-141C501
820-340G502
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
750-801
751-901
702A
750-821
751-901
703-005
760-801
751-901
758-001
760-803
751-901
733-001
760-821
751-901
7325-105
760-822
751-901
7335-005
825-141C501
825-151C501
825-161C501
825-141G502
825-151G502
825-161G502
820-340C501
Speaker
Amplifiers
Amplifier Enclosure
726-802
821-141G502
Outdoor
Explosionproof
Stations
Consists of:
Party Line
Enclosure
Material
Aux.
Quad
NonRTU EPL
Single Multi Metallic
Receptacle
Page
Metallic
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Notes:
Unless otherwise noted, all items are UL listed for North America
** CE marked for non-hazardous areas only
GAI-TRONICS® A Hubbell Company
Toll Free: 1-800-492-1212
Tel: 610-777-1374
FAX: 610-796-5954
www.gai-tronics.com
ADVANCE SmartSeries™
Indoor and Outdoor Stations
Model and Part Numbers
Consists of:
Order
Model
No.
Amplifier
Enclosure
700-802
701-902
702A
700-803
701-904
702A
7005-802
701-902
703A
7005-803
701-904
703A
7005-821
701-902
703-005
7005-822
701-904
703-005
7005-831
701-902
703-004
7005-832
701-904
703-004
730-803
701-902
732-101
730-804
701-902
733-001
730-805
701-904
732-101
730-806
701-904
733-001
7305-803
701-902
7325-101
7305-804
701-902
7335-001
7306-806
701-904
7325-101
7305-807
701-904
7335-001
7305-821
701-902
7325-105
7305-822
701-902
7335-005
7305-823
701-904
7325-105
7305-824
701-904
7335-005
7305-831
701-902
7335-004
7305-832
701-904
7335-004
7305-833
701-902
7325-104
7305-834
701-904
7325-104
GAI-TRONICS® A Hubbell Company
Subset
Toll Free: 1-800-492-1212
Party Line
Aux.
Receptacle
RTU
EPL
Quad
Single Multi Metallic
Page
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Tel: 610-777-1374
Enclosure
Material
•
•
•
•
FAX: 610-796-5954
NonMetallic
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
www.gai-tronics.com
Contact your sales
representative or call
our toll-free sales
hotline for further
information at
1-800-492-1212.
Visit our Web site at
www.gai-tronics.com
Look to GAI-Tronics®, a leader in
the emergency notification industry
through its innovative products,
uncompromising quality and
advanced technological experience
GAI-Tronics® - USA (Corporate) Toll Free: 1 (800) 492-1212 Tel: (610) 777-1374 Fax: (610) 796-5954 www.gai-tronics.com
GAI-Tronics® United Kingdom Tel: +44 (0)1283 500500 Fax: +44 (0)1283 500400 www.gai-tronics.co.uk
GAI-Tronics® S.r.l - Italy Tel: +39 02 48601460 Fax: +39 02 93663110 www.gai-tronics.it
GAI-Tronics® - Malaysia Tel: +60-3-8945-4035 / 8945-7348 Fax: +60-3-8945-4675 www.gai-tronics.com
GAI-Tronics® Austdac - Australia Tel: 011-61-28-851-5000 Fax: 011-61-29-899-2490 www.austdac.com.au
Quality Management System Certified by DNV - ISO 9001:2008
Pub 961109 Rev. 9/2013
The policy of GAI-Tronics is one of continuous improvement, therefore the company reserves the right to change specifications without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF