Rosemount 2051 Datasheet - eswl

Rosemount 2051 Datasheet - eswl
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Rosemount 2051 Pressure Transmitter
• Reference Accuracy of 0.075%
• Rangeability of 100:1
• Protocols available include 4-20 mA HART®,
FOUNDATION™ fieldbus, 1-5 Vdc HART Low
Power
• Coplanar™ platform enables integration of
primary elements, manifolds, and diaphragm
seal solutions
• Complete pressure transmitter family to meet
your pressure, level, and flow needs
Contents
Product Offering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Product Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 26
www.rosemount.com
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Measure Pressure with Confidence
Confidence Begins with Reliable
Measurement
Reduce Engineering and Installed Cost
with Flexible Coplanar Design
The 2051 capabilities are designed to meet a wide
range of applications. Combining 0.075% reference
accuracy, 100:1 rangedown, and extended two-year
stability provides confidence in your pressure
measurements.
The versatile Coplanar platform design enables the
best process connection for pressure, flow, and level
applications. The final 2051 assembly arrives factory
calibrated, pressure-tested, and ready to install. The
flexible design reduces engineering and inventory
costs.
Integrate With Any Host
The 2051 is available in 4-20mA HART, Low Power
HART, or FOUNDATION fieldbus output protocols.
Easily integrate the 2051 into existing or new
installations.
Meet Your Application Needs with a
Complete Offering
The 2051 family of pressure transmitters offers
differential, gage, and absolute pressure
measurements. The complete offering ensures the
2051 meets your measurement needs.
Rosemount Pressure Solutions
Rosemount 3051S Series of Instrumentation
Highest performing scalable pressure, flow and level
measurement solutions drive better plant efficiency and more
productivity. Innovative features include wireless, advanced
diagnostics, and multivariable technologies.
Rosemount 3095 Mass Flow Transmitter
Accurately measures differential pressure, static pressure and
process temperature to dynamically calculate fully compensated
mass flow.
Rosemount 3051 Pressure Transmitter Family
Proven industry standard performance and reliability to increase
plant profitability. Includes the most comprehensive offering to
meet all application needs.
Rosemount 305, 306 and 304 Manifolds
Factory-assembled, calibrated and seal-tested
transmitter-to-manifold assemblies reduce installation costs.
Rosemount 1199 Diaphragm Seals
Provides reliable, remote measurements of process pressure and
protects the transmitter from hot, corrosive, or viscous fluids.
Orifice Plate Primary Element Systems: Rosemount
1495 and 1595 Orifice Plates, 1496 Flange Unions and
1497 Meter Sections
A comprehensive offering of orifice plates, flange unions and
meter sections that are easy to specify and order. The 1595
Conditioning Orifice provides superior performance in tight fit
applications.
Annubar® Flowmeter Series: Rosemount 3051SFA
ProBar®, 3095MFA Mass ProBar, and 485
The state-of-the-art, fifth generation Rosemount 485 Annubar
combined with the 3051S or 3095 MultiVariable transmitter creates
an accurate, repeatable and dependable insertion-type flowmeter.
Compact Orifice Flowmeter Series: Rosemount
3051SFC, 3095MFC, and 405
Compact Orifice Flowmeters can be installed between existing
flanges, up to a Class 600 (PN100) rating. In tight fit applications,
a conditioning orifice plate version is available, requiring only two
diameters of straight run upstream and two downstream.
ProPlate® Flowmeter Series: Rosemount 3051SFP
ProPlate, 3095MFP Mass ProPlate, and 1195
These integral orifice flowmeters eliminate the inaccuracies that
become more pronounced in small orifice line installations. The
completely assembled, ready to install flowmeters reduce cost and
simplify installation.
2
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Product Offering
Rosemount 2051C Differential and Gage
See ordering information on page 26.
•
Performance of 0.075% accuracy, optional 0.065%
•
Two-year stability of 0.10%, optional five-year stability
•
Coplanar platform enables integrated manifold,
primary element and diaphragm seal solutions
•
Calibrated spans/ranges from 0.5 inH2O to 2000 psi
(1,2 mbar to 138 bar)
•
316L SST and Alloy C-276 process wetted parts
Rosemount 2051T Gage and Absolute
See ordering information on page 30.
• Performance of 0.075% accuracy, optional 0.065%
• Two-year stability of 0.10%, optional
five-year stability
• Calibrated spans/ranges from 0.3 to 10000 psi
(10,3 mbar to 689 bar)
• Multiple process connections available
• 316L SST and Alloy C-276 process wetted parts
Rosemount 2051L Liquid Level
See ordering information on page 33.
•
Performance of 0.075% accuracy
•
Welded fill fluid system provides
best-in-class system reliability
•
Flush and extended diaphragms
•
Multiple fill fluids and process wetted
materials available
3
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Specifications
PERFORMANCE SPECIFICATIONS
For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange (2051C) or 1/2 in. - 14 NPT (2051T) process connections,
digital trim values set to equal range points. Applicable to 4-20 mA HART output only unless otherwise noted.
Conformance To Specification (±3σ (Sigma))
Technology leadership, advanced manufacturing techniques and statistical process control ensure specification conformance to at least ±3σ.
Reference Accuracy(1)
Models(1)
Standard
Performance Option, P8
±0.075% of span
For spans less than 10:1, accuracy =
Ranges 2-5
2051C
Ranges 2-5
URL
± 0.025 + 0.005 ⎛ ---------------⎞ % of Span
⎝ Span⎠
Range 1
High Accuracy Option, P8
±0.065% of span
For spans less than 10:1, accuracy =
URL
± 0.015 + 0.005 ⎛ ---------------⎞ % of Span
⎝ Span⎠
±0.10% of span
For spans less than 15:1, accuracy =
URL
± 0.025 + 0.005 ⎛ ---------------⎞ % of Span
⎝ Span⎠
2051T
Ranges 1-4
±0.075% of span
For spans less than 10:1, accuracy =
Ranges 1-4
URL
± 0.0075 ⎛ ---------------⎞ % of Span
⎝ Span⎠
Range 5
±0.075% of span for spans greater than 5:1
2051L
Ranges 2-4
±0.075% of span
For spans less than 10:1, accuracy =
URL
± 0.025 + 0.005 ⎛ ---------------⎞ % of Span
⎝ Span⎠
(1) For FOUNDATION fieldbus transmitters, use calibrated range in place of span.
4
High Accuracy Option, P8
±0.065% of span
For spans less than 10:1, accuracy =
URL
± 0.0075 ⎛ ---------------⎞ % of Span
⎝ Span⎠
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Long Term Stability
Models
Standard
Performance Option, P8
Range 1 (CD)
Ranges 2-5
±0.2% of URL for 1 year, Reference Stability
±0.1% of URL for 2 years, Operating Stability
±0.125% of URL for 5 years, Operating Stability
Ranges 1-5
±0.1% of URL for 2 years, Operating Stability
±0.125% of URL for 5 years, Operating Stability
Ranges 2-4
Not Specified
2051CD, CG
2051T
2051L
Dynamic Performance
4-20 mA HART(1)
1-5 Vdc HART Low Power
Fieldbus(3)
Typical HART Transmitter Response Time
(2)
Total Response Time (Td + Tc)
2051C, Range 3-5:
Range 1:
Range 2:
2051T:
2051L:
Dead Time (Td)
Update Rate
:
115 milliseconds
270 milliseconds
130 milliseconds
100 milliseconds
See Instrument Toolkit®
60 milliseconds (nominal)
22 times per second
152 milliseconds
307 milliseconds
152 milliseconds
152 milliseconds
See Instrument Toolkit
97 milliseconds
22 times per second
Transmitter Output vs. Time
Pressure Released
Td
100%
Tc
Td = Dead Time
Tc = Time Constant
Response Time = Td +Tc
63.2% of Total
Step Change
36.8%
(1) Dead time and update rate apply to all models and ranges; analog output only
(2) Nominal total response time at 75 °F (24 °C) reference conditions.
(3) Transmitter fieldbus output only, segment macro-cycle not included.
0%
Time
Line Pressure Effect per 1000 psi (6,9 MPa)
For line pressures above 2000 psi (13,7 MPa) and Ranges 4-5, see user manual (Rosemount publication number 00809-0100-4101).
Models
2051CD
Line Pressure Effect
Zero Error(1)
Ranges 2-3 ±0.1% of URL/1000 psi (68,9 bar) for line pressures from 0 to 2000 psi (0 to 13,7 MPa)
Range 1 ±0.5% of URL/1000 psi (68,9 bar)
Span Error
Ranges 2-3 ±0.1% of reading/1000 psi (68,9 bar)
Range 1 ±0.4% of reading/1000 psi (68,9 bar)
(1) Can be calibrated out at line pressure.
5
Product Data Sheet
Rosemount 2051
00813-0100-4101, Rev BA
February 2009
Ambient Temperature Effect per 50°F (28°C)
Models
Ambient Temperature Effect
2051C
Ranges 2-5 ±(0.025% URL + 0.125% span) from 1:1 to 5:1
±(0.05% URL + 0.25% span) from 5:1 to 100:1
Range 1 ±(0.2% URL + 0.5% span) from 1:1 to 50:1
2051T
Range 2-4
Range 1
Range 5
2051L
±(0.05% URL + 0.25% span) from 1:1 to 30:1
±(0.07% URL + 0.25% span) from 30:1 to 100:1
±(0.05% URL + 0.25% span) from 1:1 to 10:1
±(0.10% URL + 0.25% span) from 10:1 to 100:1
±(0.2% URL + 0.3% span)
See Instrument Toolkit
Mounting Position Effects
Models
Mounting Position Effects
2051C
2051T
2051L
Zero shifts up to ±1.25 inH2O (3,1 mbar), which can be calibrated out. No span effect.
Zero shifts up to ±2.5 inH2O (6,2 mbar), which can be calibrated out. No span effect.
With liquid level diaphragm in vertical plane, zero shift of up to 1 inH2O (2,49 mbar). With diaphragm in
horizontal plane, zero shift of up to 5 inH2O (12,43 mbar) plus extension length on extended units. Zero
shifts can be calibrated out. No span effect.
Vibration Effect
Less than ±0.1% of URL when tested per the requirements of
IEC60770-1 field or pipeline with high vibration level (10-60 Hz
0.21mm displacement peak amplitude / 60-2000 Hz 3g).
Power Supply Effect
Less than ±0.005% of calibrated span per volt.
Electromagnetic Compatibility (EMC)
Meets all relevant requirements of EN 61326 and NAMUR NE-21.
Transient Protection (Option Code T1)
Meets IEEE C62.41, Category Location B
6 kV crest (0.5 μs - 100 kHz)
3 kV crest (8 × 20 microseconds)
6 kV crest (1.2 × 50 microseconds)
6
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
FUNCTIONAL SPECIFICATIONS
Range and Sensor Limits
Range
2051CD, 2051CG, 2051L
1
2
3
4
5
Range and Sensor Limits
Lower (LRL)
Minimum Span
Upper (URL)
2051C Differential
2051C Gage(1)
2051L Differential
2051L Gage(1)
0.5 inH2O
(1,2 mbar)
2.5 inH2O
(6,2 mbar)
10 inH2O
(24,9 mbar)
3 psi
(0,207 bar)
20 psi
(1,38 bar)
25 inH2O
(62,3 mbar)
250 inH2O
(0,62 bar)
1000 inH2O
(2,49 bar)
300 psi
(20,6 bar)
2000 psi
(137,9 bar)
–25 inH2O
(–62,1 mbar)
–250 inH2O
(–0,62 bar)
-1000 inH2O
(-2,49 bar)
-300 psi
(-20,6 bar)
-2000 psi
(-137,9 bar)
–25 inH2O
(–62,1 mbar)
–250 inH2O
(–0,62 bar)
–393 inH2O
(–979 mbar)
–14.2 psig
(–979 mbar)
–14.2 psig
(–979 mbar)
N/A
N/A
–250 inH2O
(–0,62 bar)
–1000 inH2O
(–2,49 bar)
–300 psi
(–20,7 bar)
N/A
–250 inH2O
(–0,62 bar)
–393 inH2O
(–979 mbar)
–14.2 psig
(–979 mbar)
N/A
(1) Assumes atmospheric pressure of 14.7 psig.
Range
2051T
1
2
3
4
5
Range and Sensor Limits
Minimum
Span
Upper
(URL)
Lower
(LRL) (Abs)
Lower(1)
(LRL) (Gage)
0.3 psi
(20,6 mbar)
1.5 psi
(0,103 bar)
8 psi
(0,55 bar)
40 psi
(2,76 bar)
2000 psi
(137,9 bar)
30 psi
(2,06 bar)
150 psi
(10,3 bar)
800 psi
(55,2 bar)
4000 psi
(275,8 bar)
10000 psi
(689,4 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
–14.7 psig
(–1,01 bar)
–14.7 psig
(–1,01 bar)
–14.7 psig
(–1,01 bar)
–14.7 psig
(–1,01 bar)
–14.7 psig
(–1,01 bar)
(1) Assumes atmospheric pressure of 14.7 psig.
7
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Service
FOUNDATION fieldbus Parameters
Schedule Entries
Links
Virtual Communications Relationships (VCR)
Liquid, gas, and vapor applications
Protocols
7 (max.)
20 (max.)
12 (max.)
Standard Function Blocks
4–20 mA HART (Output Code A)
Resource Block
Output
• Contains hardware, electronics, and diagnostic information.
Two-wire 4–20 mA, user-selectable for linear or square root
output. Digital process variable superimposed on 4–20 mA
signal, available to any host that conforms to the HART
protocol.
Transducer Block
Power Supply
LCD Block
External power supply required. Standard transmitter operates
on 10.5 to 42.4 V dc with no load.
• Configures the local display.
Turn-On Time
• Processes the measurements for input into other function
blocks. The output value is in engineering units or custom
and contains a status indicating measurement quality.
Performance within specifications less than 2.0 seconds after
power is applied to the transmitter.
• Contains actual sensor measurement data including the
sensor diagnostics and the ability to trim the pressure
sensor or recall factory defaults.
2 Analog Input Blocks
PID Block
Load Limitations
Maximum loop resistance is determined by the voltage level of
the external power supply, as described by:
• Contains all logic to perform PID control in the field including
cascade and feedforward.
Backup Link Active Scheduler (LAS)
Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 10.5)
Load (Ohms)
1387
The transmitter can function as a Link Active Scheduler if the
current link master device fails or is removed from the
segment.
1000
1-5 Vdc HART Low Power (Output Code M)
500
Operating
Region
Output
0
10.5
20
30
Voltage (V dc)
42.4
The HART communicator requires a minimum
loop resistance of 250Ω for communication.
FOUNDATION fieldbus (Output Code F)
Three wire 1–5 Vdc output, user-selectable for linear or
square root output. Digital process variable superimposed on
voltage signal, available to any host conforming to the HART
protocol.
Power Supply
External power supply required. Standard transmitter operates
on 9 to 28 Vdc with no load.
Power Consumption
Power Supply
3.0 mA, 27–84 mW
External power supply required; transmitters operate on 9.0 to
32.0 V dc transmitter terminal voltage.
100 kΩ or greater
Current Draw
17.5 mA for all configurations (including LCD display option)
Turn-On Time
Turn-On Time
Performance within specifications less than 2.0 seconds after
power is applied to the transmitter.
Performance within specifications less than 20.0 seconds after
power is applied to the transmitter.
FOUNDATION fieldbus Function Block Execution Times
Block
Execution Time
Resource
Transducer
LCD Block
Analog Input 1, 2
PID
8
Output Load
30 milliseconds
45 milliseconds
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Overpressure Limits
Temperature Limits
Transmitters withstand the following limits without damage:
Ambient(1)
–40 to 185 °F (–40 to 85 °C)
2051C
With LCD display(2): –40 to 175 °F (–40 to 80 °C)
• Ranges 2–5: 3626 psig (250 bar)
4500 psig (310,3 bar) for option code P9
Storage(1)
• Range 1: 2000 psig (137,9 bar)
–50 to 230 °F (–46 to 110 °C)
With LCD display: –40 to 185 °F (–40 to 85 °C)
2051T
(1) Limits for silicone fill fluid only.
• Range 1: 750 psi (51,7 bar)
(2) LCD display may not be readable and LCD updates will be slower
at temperatures below -4 °F (-20 °C).
• Range 2: 1500 psi (103,4 bar)
• Range 3: 1600 psi (110,3 bar)
• Range 4: 6000 psi (413,7 bar)
Process Temperature Limits
• Range 5: 15000 psi (1034,2 bar)
At atmospheric pressures and above.
TABLE 2. 2051 Process Temperature Limits
2051L
Limit is flange rating or sensor rating, whichever is lower (see
Table 1).
TABLE 1. 2051L Flange Rating
Standard
Type
CS Rating SST Rating
ANSI/ASME
Class 150
285 psig
275 psig
ANSI/ASME
Class 300
740 psig
720 psig
At 100 °F (38 °C), the rating decreases with
increasing temperature.
DIN
PN 10–40
40 bar
40 bar
DIN
PN 10/16
16 bar
16 bar
At 248 °F (120 °C), the rating decreases
with increasing temperature.
Static Pressure Limit
2051CD
• Operates within specifications between static line pressures of
-14.2 psig (0.034 bar) and 3626 psig (250 bar)
•
For Option Code P9, 4500 psig (310,3 bar)
• Range 1: 0.5 psia to 2000 psig (34 mbar and 137,9 bar)
Burst Pressure Limits
2051C Coplanar or traditional process flange
• 10000 psig (689,5 bar)
2051T
• Ranges 1–4: 11000 psi (758,4 bar)
• Range 5: 26000 psi (1792,64 bar)
2051C
Silicone Fill Sensor(1)
with Coplanar Flange
–40 to 250 °F (–40 to 121 °C)(2)
with Traditional Flange
–40 to 300 °F (–40 to 149 °C)(2)
with Level Flange
–40 to 300 °F (–40 to 149 °C)(2)
with 305 Integral Manifold –40 to 300 °F (–40 to 149 °C)(2)
Inert Fill Sensor(1)
0 to 185 °F (–18 to 85 °C)(3)
2051T (Process Fill Fluid)
Silicone Fill Sensor(1)
–40 to 250 °F (–40 to 121 °C)(2)
Inert Fill Sensor(1)
–22 to 250 °F (–30 to 121 °C)(2)
2051L Low-Side Temperature Limits
Silicone Fill Sensor(1)
–40 to 250 °F (–40 to 121 °C)(2)
Inert Fill Sensor(1)
0 to 185 °F (–18 to 85 °C) (2)
2051L High-Side Temperature Limits (Process Fill Fluid)
Syltherm® XLT
D.C. Silicone 704®
D.C. Silicone 200
Inert
Glycerin and Water
Neobee M-20
Propylene Glycol and
Water
–100 to 300 °F (–73 to 149 °C)
32 to 400 °F (0 to 205 °C)
–40 to 400 °F (–40 to 205 °C)
–50 to 350 °F (–45 to 177 °C)
0 to 200 °F (–18 to 93 °C)
0 to 400 °F (–18 to 205 °C)
0 to 200 °F (–18 to 93 °C)
(1) Process temperatures above 185 °F (85 °C) require derating
the ambient limits by a 1.5:1 ratio.
(2) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for
pressures below 0.5 psia.
(3) 160 °F (71 °C) limit in vacuum service.
Humidity Limits
0–100% relative humidity
Volumetric Displacement
Less than 0.005 in3 (0,08 cm3)
Damping
Analog output response to a step input change is user-selectable
from 0 to 25.6 seconds for one time constant. This software
damping is in addition to sensor module response time.
9
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Failure Mode Alarm
2051C Process Wetted Parts
If self-diagnostics detect a sensor or microprocessor failure, the
analog signal is driven either high or low to alert the user. High or
low failure mode is user-selectable with a jumper on the
transmitter. The values to which the transmitter drives its output in
failure mode depend on whether it is factory-configured to
standard or NAMUR-compliant operation. The values for each are
as follows:
Standard Operation
Drain/Vent Valves
Output Code
Linear Output
3.9 ≤ I ≤ 20.8
0.97 ≤ V ≤ 5.2
A
M
Fail High
Fail Low
I ≥ 21.75 mA
V ≥ 5.4 V
I ≤ 3.75 mA
V ≤ 0.95V
316 SST or Alloy C-276
Process Flanges and Adapters
Plated carbon steel, SST CF-8M (cast version of 316 SST,
material per ASTM-A743), or CW12MW (cast version of Alloy
C-276)
Wetted O-rings
Glass-filled PTFE or Graphite-filled PTFE
Process Isolating Diaphragms
NAMUR-Compliant Operation
Output Code
Linear Output
3.8 ≤ I ≤ 20.5
A
316L SST or Alloy C-276
Fail High
Fail Low
I ≥ 22.5 mA
I ≤ 3.6 mA
2051T Process Wetted Parts
Process Connections
Output Code F
If self-diagnostics detect a gross transmitter failure, that
information gets passed as a status along with the process
variable.
• 316L SST or Alloy C-276
Process Isolating Diaphragms
• 316L SST or Alloy C-276
PHYSICAL SPECIFICATIONS
2051L Process Wetted Parts
Electrical Connections
1
/2–14 NPT, G1/2, and M20 × 1.5 (CM20) conduit.
Flanged Process Connection (Transmitter High Side)
Process Diaphragms, Including Process Gasket Surface
Process Connections
•
2051C
Extension
• 1/4–18 NPT on 21/8-in. centers
•
• 1/2–14 NPT and RC 1/2 on 2-in.(50.8mm), 21/8-in. (54.0 mm),
or 21/4-in. (57.2mm) centers (process adapters)
•
CF-3M (Cast version of 316L SST, material per
ASTM-A743), or Cast C-276. Fits schedule 40 and 80
pipe.
Mounting Flange
2051T
1/2–14
316L SST or Alloy C-276
•
NPT female
Zinc-cobalt plated CS or SST
1
• G /2 A DIN 16288 Male (available in SST for Range 1–4
transmitters only)
9/16–18
gland
• Autoclave type F-250-C (Pressure relieved
thread; 1/4 OD high pressure tube 60° cone; available in SST
for Range 5 transmitters only)
Reference Process Connection (Transmitter Low Side)
Isolating Diaphragms
•
316L SST or Alloy C-276
Reference Flange and Adapter
2051L
• High pressure side: 2-in.(50.8mm), 3-in. (72 mm), or 4-in.
(102mm), ASME B 16.5 (ANSI) Class 150 or 300 flange;
50, 80 or 100 mm, DIN 2501 PN 40 or 10/16 flange
• Low pressure side: 1/4–18 NPT on flange, 1/2–14 NPT on
process adapter
10
•
CF-8M (Cast version of 316 SST, material per
ASTM-A743)
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Non-Wetted Parts for 2051C/T/L
Electronics Housing
Low-copper aluminum or CF-8M (Cast version of 316 SST).
Enclosure Type 4X, IP 65, IP 66, IP68
Coplanar Sensor Module Housing
Rosemount 2051
Shipping Weights
TABLE 3. Transmitter Weights without Options
Transmitter
lb. (kg)
2051C
2051L
2051T
4.9 (2,2)
Table 4 below
3.1 (1,4)
CF-3M (Cast version of 316L SST)
Bolts
ASTM A449, Type 1 (zinc-cobalt plated carbon steel)
ASTM F593G, Condition CW1 (Austenitic 316 SST)
ASTM A193, Grade B7M (zinc plated alloy steel)
Sensor Module Fill Fluid
Silicone oil (D.C. 200) or Fluorocarbon oil (Halocarbon or
Fluorinert® FC-43 for 2051T)
Process Fill Fluid (2051L only)
Syltherm XLT, D.C. Silicone 704,
D.C. Silicone 200, inert, glycerin and water, Neobee M-20 or
propylene glycol and water
Paint
Polyurethane
TABLE 4. 2051L Weights without Options
Flange
2-in., 150
3-in., 150
4-in., 150
2-in., 300
3-in., 300
4-in., 300
DN 50/PN 40
DN 80/PN 40
DN 100/
PN 10/16
DN 100/
PN 40
Flush
lb. (kg)
2-in. Ext.
lb (kg)
4-in. Ext.
lb (kg)
6-in. Ext.
lb (kg)
12.5 (5,7)
17.5 (7,9)
23.5 (10,7)
17.5 (7,9)
22.5 (10,2)
32.5 (14,7)
13.8 (6,2)
19.5 (8,8)
17.8 (8,1)
—
19.5 (8,8)
26.5 (12,0)
—
24.5 (11,1)
35.5 (16,1)
—
21.5 (9,7)
19.8 (9,0)
—
20.5 (9,3)
28.5 (12,9)
—
25.5 (11,6)
37.5 (17,0)
—
22.5 (10,2)
20.8 (9,5)
—
21.5 (9,7)
30.5 (13,8)
—
26.5 (12,0)
39.5 (17,9)
—
23.5 (10,6)
21.8 (9,9)
23.2 (10,5)
25.2 (11,5)
26.2 (11,9)
27.2 (12,3)
Cover O-rings
Buna-N
TABLE 5. Transmitter Options Weights
Code
J, K, L, M
M5
B4
B1 B2 B3
B7 B8 B9
BA, BC
H2
H3
H4
H7
FC
FD
FA
FB
FP
FQ
Option
Add
lb (kg)
Stainless Steel Housing
3.9 (1,8)
LCD display for Aluminum Housing
0.5 (0,2)
SST Mounting Bracket for Coplanar Flange 1.0 (0,5)
Mounting Bracket for Traditional Flange
2.3 (1,0)
Mounting Bracket for Traditional Flange
2.3 (1,0)
SST Bracket for Traditional Flange
2.3 (1,0)
Traditional Flange
2.6 (1,2)
Traditional Flange
3.0 (1,4)
Traditional Flange
3.0 (1,4)
Traditional Flange
2.7 (1,2)
Level Flange—3 in., 150
12.7 (5,8)
Level Flange—3 in., 300
15.9 (7,2)
Level Flange—2 in., 150
8.0 (3,6)
Level Flange—2 in., 300
8.4 (3,3)
DIN Level Flange, SST, DN 50, PN 40
7.8 (3,5)
DIN Level Flange, SST, DN 80, PN 40
12.7 (5,8)
11
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Product Certifications
Approved Manufacturing Locations
Rosemount Inc. — Chanhassen, Minnesota USA
Emerson Process Management GmbH & Co. — Wessling,
Germany
Emerson Process Management Asia Pacific
Private Limited — Singapore
Beijing Rosemount Far East Instrument Co., LTD — Beijing, China
European Directive Information
The EC declaration of conformity for all applicable European
directives for this product can be found on the Rosemount website
at www.rosemount.com. A hard copy may be obtained by
contacting an Emerson Process Management representative.
HART PROTOCOL
Hazardous Locations Certifications
North American Certifications
FM Approvals
E5
Explosion-Proof for Class I, Division 1, Groups B, C, and D.
Dust-Ignition-Proof for Class II, Division 1, Groups E, F, and
G. Dust-Ignition-Proof for Class III, Division 1.
T5 (Ta = 85 °C), Factory Sealed, Enclosure Type 4X
I5
Intrinsically Safe for use in Class I, Division 1, Groups A, B,
C, and D; Class II, Division 1, Groups E, F, and G; Class III,
Division 1 when connected per Rosemount drawing
02051-1009; Non-incendive for Class I, Division 2, Groups
A, B, C, and D.
Temperature Code:T4 (Ta = 40 °C), T3 (Ta = 85 °C),
Enclosure Type 4X
For input parameters see control drawing 02051-1009.
ATEX Directive (94/9/EC)
All 2051 transmitters comply with the ATEX Directive.
European Pressure Equipment Directive (PED) (97/23/EC)
2051CG2, 3, 4, 5; 2051CD2, 3, 4, 5 (also with P9 option)
— QS Certificate of Assessment - EC No. PED-H-100
Module H Conformity Assessment
All other 2051 Pressure Transmitters
— Sound Engineering Practice
Transmitter Attachments: Diaphragm Seal - Process
Flange - Manifold
Canadian Standards Association (CSA)
All CSA hazardous approved transmitters are certified per
ANSI/ISA 12.27.01-2003.
E6
Explosion-Proof for Class I, Division 1, Groups B, C, and D.
Dust-Ignition-Proof for Class II and Class III, Division 1,
Groups E, F, and G. Suitable for Class I, Division 2 Groups
A, B, C, and D for indoor and outdoor hazardous locations.
Enclosure type 4X, factory sealed
I6
Intrinsically safe approval. Intrinsically safe for Class I,
Division 1, Groups A, B, C, and D when connected in
accordance with Rosemount drawing 02051-1008.
Temperature Code T3C.
Dust-Ignition-Proof for Class II and Class III, Division 1,
Groups E, F, and G. Suitable for Class I, Division 2 Groups
A, B, C, and D hazardous locations. Enclosure type 4X,
factory sealed
For input parameters see control drawing 02051-1008.
— Sound Engineering Practice
Electro Magnetic Compatibility (EMC) (2004/108/EC)
All 2051 Pressure Transmitters meet all of the requirements of
IECEN61326:2006 and NAMUR NE-21.
Ordinary Location Certification for Factory Mutual
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical,
and fire protection requirements by FM, a nationally recognized
testing laboratory (NRTL) as accredited by the Federal
Occupational Safety and Health Administration (OSHA).
12
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
European Certifications
I1
ATEX Intrinsic Safety
Certification No. Baseefa08ATEX0129X
Ex ia IIC T4 (–60 ≤ Ta ≤ +70 °C)
IP66 IP68
1180
ND
II 1 G
Special Conditions for Safe Use (X):
If the equipment is fitted with an optional 90V transient
suppressor, it is incapable of isolation from earth test and
this must be taken into account during installation.
TABLE 6. Input Parameters
Ui = 30V
Ii = 200 mA
Pi = 1.0W
Ci = 0.012 µF
Li = 10 µH
IECEx Certifications
I7
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is
installed, the apparatus is not capable of withstanding the
500V insulation test required by Clause 6.3.12 of
EN60079-11. This must be taken into account when
installing the apparatus.
N1
ATEX Type n
Certification No. Baseefa08ATEX0130X
Ex nAnL IIC T4 (–40 ≤ Ta ≤ +70 °C)
Ui = 42.4 Vdc max
IP66
ATEX Flame-Proof
Certification No. KEMA 08ATEX0090X G
Ex d IIC T6 (–50 ≤ Ta ≤ 65 °C)
Ex d IIC T5 (–50 ≤ Ta ≤ 80 °C)
IP66
1180
Vmax = 42.4 V dc
II 1/2 G
Special Conditions for Safe Use (X):
This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure safety
during its expected lifetime.
IECEx Intrinsic Safety
Certification No. IECExBAS08.0045X II 1 G
Ex ia IIC T4 (–60 ≤ Ta ≤ +70 °C)
1180
TABLE 7. Input Parameters
Ui = 30V
Ii = 200 mA
Pi = 1.0W
Ci = 0.012 µF
II 3 G
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is
installed, the apparatus is not capable of withstanding a
500V r.m.s. test to case. This must be taken into account on
any installation in which it is used, for example by assuring
that the supply to the apparatus is galvanically isolated.
E1
ATEX Dust
Certification No. Baseefa08ATEX0182X
II 1 D
Dust Rating: II 1 D Ex tD A20 T115 °C (-20 °C ≤ Ta ≤ 85 °C)
IP66 IP68
Vmax = 42.4 V dc
A = 22 mA
1180
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is
installed, the apparatus is not capable of withstanding the
500V insulation test required by Clause 6.3.12 of
IEC60079-11. This must be taken into account when
installing the apparatus.
E7
IECEx Explosion-Proof (Flame-Proof)
Certification No. IECEx KEM 08.0024X II 1/2 G
Ex d IIC T6 (–50 ≤ Ta ≤ 65 °C)
Ex d IIC T5 (–50 ≤ Ta ≤ 80 °C)
1180
Vmax = 42.4 V dc
Special Conditions for Safe Use (X):
This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure safety
during its expected lifetime.
13
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
N7
IECEx Type n
Certification No. IECExBAS08.0046X II 3 G
Ex nAnL IIC T4 (–40 ≤ Ta ≤ +70 °C)
Ui = 42.4 Vdc max
China (NEPSI) Certifications
E3
Flame-Proof
Ex d II B+H2T3~T5
I3
Intrinsic Safety
Ex ia IIC T4
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is
installed, the apparatus is not capable of withstanding a
500V r.m.s. test to case. This must be taken into account on
any installation in which it is used, for example by assuring
that the supply to the apparatus is galvanically isolated.
KOSHA Certifications
EP
Flame-Proof
Ex d IIB+H2 T5
IP
Intrinsic Safety
Ex ia IIC T3
TIIS Certifications
E4
I4
TIIS Flame-Proof
Ex d IIC T6
TIIS Intrinsic Safety
Ex ia IIC T4
CCoE Certifications
IW
Intrinsic Safety
Ex ia IIC T4
EW
Flame-Proof
Ex d IIC T5 or T6
Inmetro Certifications
E2
Flame-Proof
BR-Ex d IIC T6/T5
I2
Intrinsic Safety
BR-Ex ia IIC T4
GOST Certifications
IM
EM
14
Intrinsic Safety
Certificate Pending
Flame-Proof
Certificate Pending
Combinations of Certifications
Stainless steel certification tag is provided when optional approval
is specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval
types. Permanently mark the approval label to distinguish it from
unused approval types.
K1
E1, I1, N1, and ND combination
K2
E2 and I2 combination
K4
E4 and I4 combination
K5
E5 and I5 combination
K6
I6 and E6 combination
K7
E7, I7, and N7 combination
KA
E1, I1, E6, and I6 combination
KB
E5, I5, E6, and I6 combination
KC
E1, I1, E5, and I5 combination
KD
E1, I1, E5, I5, E6, and I6 combination
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
FIELDBUS PROTOCOL
Hazardous Locations Certifications
North American Certifications
IA
FM Approvals
E5
Explosion-Proof for Class I, Division 1, Groups B, C, and D.
Dust-Ignition-Proof for Class II, Division 1, Groups E, F, and
G. Dust-Ignition-Proof for Class III, Division 1.
Ui = 17.5 V
Ii = 380 mA
Pi = 5.32 W
Ci = ≤ 5 µF
Li = ≤ 10 µH
I5/IE Intrinsically Safe for use in Class I, Division 1, Groups A, B,
C, and D; Class II, Division 1, Groups E, F, and G; Class III,
Division 1 when connected per Rosemount drawing
02051-1009; Non-incendive for Class I, Division 2, Groups
A, B, C, and D.
Special Conditions for Safe Use (X):
The device is not capable of withstanding the 500V
insulation test required by Clause 6.3.12 of EN60079-11.
This must be taken into account when installing the
apparatus.
Temperature Code:T4 (Ta = 40 °C), T3 (Ta = 85 °C),
Enclosure Type 4X
For input parameters see control drawing 02051-1009.
N1
All CSA hazardous approved transmitters are certified per
ANSI/ISA 12.27.01-2003.
E6
Explosion-Proof for Class I, Division 1, Groups B, C, and D.
Dust-Ignition-Proof for Class II and Class III, Division 1,
Groups E, F, and G. Suitable for Class I, Division 2 Groups
A, B, C, and D for indoor and outdoor hazardous locations.
Enclosure type 4X, factory sealed
I6/IF Intrinsically safe approval. Intrinsically safe for Class I,
Division 1, Groups A, B, C, and D when connected in
accordance with Rosemount drawings 02051-1008.
Temperature Code T3C.
Dust-Ignition-Proof for Class II and Class III, Division 1,
Groups E, F, and G. Suitable for Class I, Division 2 Groups
A, B, C, and D hazardous locations. Enclosure type 4X,
factory sealed
For input parameters see control drawing 02051-1008.
European Certifications
I1
ATEX Intrinsic Safety
Certification No. Baseefa08ATEX0129X
Ex ia IIC T4 (Tamb = –60 to +60 °C)
IP66
1180
II 1 G
II 1 G
TABLE 9. Input Parameters
T5 (Ta = 85 °C), Factory Sealed, Enclosure Type 4X
Canadian Standards Association (CSA)
ATEX FISCO Intrinsic Safety
Certification No. Baseefa08ATEX0129X
Ex ia IIC T4 (Tamb = –60 to +60 °C)
IP66
1180
ATEX Type n
Certification No. Baseefa08ATEX0130X
Ex nAnL IIC T4 (Tamb = –40 to +70 °C)
Ui = 32 Vdc max
IP66
II 3 G
Special Conditions for Safe Use (X):
The device is not capable of withstanding the 500V
insulation test required by Clause 6.8.1 of EN60079-15. This
must be taken into account when installing the apparatus.
E1
ATEX Flame-Proof
Certification No. KEMA 08ATEX0090X G
Ex d IIC T6 (Tamb = –50 to 65 °C)
Ex d IIC T5 (Tamb = –50 to 80 °C)
IP66
1180
Vmax = 32 V dc
II 1/2 G
Special Conditions for Safe Use (X):
This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure safety
during its expected lifetime.
TABLE 8. Input Parameters
Ui = 30V
Ii = 300 mA
Pi = 1.3 W
Ci = 0 µF
Li = 0 uH
Special Conditions for Safe Use (X):
The device is not capable of withstanding the 500V
insulation test required by Clause 6.3.12 of EN60079-11.
This must be taken into account when installing the
apparatus.
15
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
ND
ATEX Dust
Certification No. Baseefa08ATEX0182X
II 1 D
Dust Rating: II 1 D Ex tD A20 T115 °C (-20 °C ≤ Ta ≤ 85 °C)
IP66 IP68
Vmax = 42.4 V dc
A = 22 mA
1180
E7
Special Conditions for Safe Use (X):
Special Conditions for Safe Use (X):
If the equipment is fitted with an optional 90V transient
suppressor, it is incapable of isolation from earth test and
this must be taken into account during installation.
This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure safety
during its expected lifetime.
IECEx Certifications
I7
IECEx Intrinsic Safety
Certification No. IECExBAS08.0045X II 1 G
Ex ia IIC T4 (Tamb = –60 to +60 °C)
IP66
1180
N7
TABLE 10. Input Parameters
Ui = 30V
Ii = 300 mA
Pi = 1.3 W
Ci = 0 µF
ATEX FISCO Intrinsic Safety
Certification No. IECExBAS08.0045X
Ex ia IIC T4 (Tamb = –60 to +60 °C)
IP66
1180
The device is not capable of withstanding the 500V
insulation test required by Clause 6.8.1 of IEC60079-15.
This must be taken into account when installing the device.
II 1 G
TABLE 11. Input Parameters
Ui = 17.5 V
Ii = 380 mA
Pi = 5.32 W
Ci = ≤ 5 µF
Li = ≤ 10 µH
Special Conditions for Safe Use (X):
The device is not capable of withstanding the 500V
insulation test required by Clause 6.3.12 of EN60079-11.
This must be taken into account when installing the
apparatus.
16
IECEx Type n
Certification No. IECExBAS08.0046X II 3 G
Ex nAnL IIC T4 (Tamb = –40 to +70 °C)
Ui = 32 Vdc max
Special Conditions for Safe Use (X):
Special Conditions for Safe Use (X):
The device is not capable of withstanding the 500V
insulation test required by Clause 6.3.12 of IEC60079-11.
This must be taken into account when installing the
apparatus.
IG
IECEx Explosion-Proof (Flame-Proof)
Certification No. IECEx KEM 08.0024X II 1/2 GD
Ex d IIC T6 (Tamb = –50 to 65 °C)
Ex d IIC T5 (Tamb = –50 to 80 °C)
IP66
1180
Vmax = 32 V dc
TIIS Certifications
E4
TIIS Flame-Proof
Ex d IIC T6
I4
TIIS Intrinsic Safety
Ex ia IIC T4
ID
TIIS FISCO Intrinsic Safety
Certificate Pending
Inmetro Certifications
E2
Flame-Proof
BR-Ex d IIC T6/T5
I2
Intrinsic Safety
BR-Ex ia IIC T4
IB
FISCO Intrinsic Safety
Certificate Pending
GOST Certifications
IM
Intrinsic Safety
Certificate Pending
EM
Flame-Proof
Certificate Pending
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
China (NEPSI) Certifications
E3
Flame-Proof
Ex d II B+H2T3~T5
I3
Intrinsic Safety
Ex ia IIC T4
KOSHA Certifications
EP
Flame-Proof
Ex d IIB+H2 T5
IP
Intrinsic Safety
Ex ia IIC T3
CCoE Certifications
IW
Intrinsic Safety
Ex ia IIC T4
EW
Flame-Proof
Ex d IIC T5 or T6
Combinations of Certifications
Stainless steel certification tag is provided when optional approval
is specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval
types. Permanently mark the approval label to distinguish it from
unused approval types.
K1
E1, I1, N1, and ND combination
K2
E2 and I2 combination
K4
E4 and I4 combination
K5
E5 and I5 combination
K6
I6 and E6 combination
K7
E7, I7, and N7 combination
KA
E1, I1, E6, and I6 combination
KB
E5, I5, E6, and I6 combination
KC
E1, I1, E5, and I5 combination
KD
E1, I1, E5, I5, E6, and I6 combination
17
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Dimensional Drawings
Dimensions are in inches (millimeters).
2051C Coplanar Flange Dimensional Drawing
5.00 (127)
4.36 (111)
3.85 (98)
7.03 (179)
6.40 (163)
2051C Coplanar with Rosemount 305 Coplanar Integral Manifold
3.85 (98)
5.00 (127)
4.36 (111)
6.19
(157)
7.44
(229)
Drain/ Vent Valve
5.50 (140)
Max Open
18
10.60 (270)
Max Open
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Coplanar Flange Mounting Configurations with
Optional Bracket (B4) for 2-in. Pipe or Panel Mounting
PANEL MOUNTING
2.82
(72)
4.36
(111)
2.18
(55)
7.03
(178)
6.15
(156)
5
/16 ⫻ 11/2 Bolts
for Panel Mounting
(Not Supplied)
2.8 (71)
3/8–16
× 11/4 Bolts
for Mounting
to Transmitter
2.81
(71)
3.4 (85)
4.73
(120)
PIPE MOUNTING
2-inch U-Bolt
for Pipe Mounting
3
/8 -16 x 11/4 Bolts
for Mounting
to Transmitter
6.22
(158)
3.4(85)
3.51
(89)
19
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
2051C Coplanar with Traditional Flange
5.00 (127)
3.85 (98)
4.36 (111)
7.76
(197)
1/2 - 14 NPT
Flange Adapter
(optional)
Drain/
Vent Valve
1.626
(41,3)
1.10 (28)
3.40 (86)
2.126
(54)
1.05 (27)
2051C Coplanar with Rosemount 305 Traditional Integral Manifold
5.00 (127)
3.85 (98)
4.36 (111)
6.19
(157)
1/2 -
14 NPT
Flange
Adapter
(optional)
Drain/
Vent Valve
1.626
(71)
3.75 (95)
Max Open
2.126
(54)
1.05
(27)
3.50
(89)
1.10
(28)
6.20 (158)
Max Open
2.70 (69)
Max Open
8.90 (226)
Max Open
20
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Traditional Flange Mounting Configurations with
Optional Brackets for 2-in. Pipe or Panel Mounting
Panel Mount (Bracket Option B2/B8)
Pipe Mount (Bracket Option B3/B9/BC)
9.18 (233)
2.62
(67)
6.19
(157)
1.94
(49)
11.51
(292)
3.56 (90)
Max Open
5.32
(135)
6.19 (157)
PANEL
MOUNTING
BRACKET
4.85
(123)
3.50
(89)
1.10
(28)
Pipe Mount (Bracket Option B1 / B7 / BA)
6.76 (172)
3.56 (90)
MAX OPEN
1.10 (28)
3.50 (89)
2.62 (67)
0.93
(24)
21
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
2051T Dimensional Drawings
5.00 (127)
4.36 (111)
3.85 (98)
7.15 (182)
2051T with Rosemount 306 Integral Manifold
3.85 (98)
5.00 (127)
4.36 (111)
7.15
(182)
4.10
(105)
4.85
(123)
6.25 (159)
Max Open
22
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
2051T Typical Mounting Configurations with Optional Mounting Bracket
Pipe Mounting
Panel Mounting
3.85
(98)
5.16 (131)
1.99 (51)
2.81 (71)
6.21
(158)
3.49
(89)
4.72
(120)
6.90
(175)
23
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
2051L Liquid Level
2-in. Flange Configuration (Flush Mount Only)
3- and 4-in. Flange Configuration
3.85
(98)
3.85
(98)
E
A
H
D
A
H
2-in., 4-in., or 6-in.
Extension
(50.8, 101.6, 152.4)
Optional Flushing Connection Ring
(Lower Housing)
5.00
(127) 4.36
(111)
G
6.60
(68)
F
7.02
(178)
E
8.12
(206)
Flushing Connection
Diaphragm Assembly and
Mounting Flange
B
24
C
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
TABLE 12. 2051L Dimensional Specifications
Except where indicated, dimensions are in inches (millimeters).
Class
ASME B16.5 (ANSI) 150
ASME B16.5 (ANSI) 300
DIN 2501 PN 10–40
DIN 2501 PN 25/40
Class(1)
ASME B16.5 (ANSI) 150
ASME B16.5 (ANSI) 300
DIN 2501 PN 10–40
DIN 2501 PN 25/40
Pipe
Size
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
4 (102)
DN 50
DN 80
DN 100
Flange
Thickness A
Bolt Circle
Diameter B
Outside
Diameter C
No. of
Bolts
Bolt Hole
Diameter
Extension
Diameter(1) D
O.D. Gasket
Surface E
0.69 (18)
0.88 (22)
0.88 (22)
0.82 (21)
1.06 (27)
1.19 (30)
20 mm
24 mm
24 mm
4.75 (121)
6.0 (152)
7.5 (191)
5.0 (127)
6.62 (168)
7.88 (200)
125 mm
160 mm
190 mm
6.0 (152)
7.5 (191)
9.0 (229)
6.5 (165)
8.25 (210)
10.0 (254)
165 mm
200 mm
235 mm
4
4
8
8
8
8
4
8
8
0.75 (19)
0.75 (19)
0.75 (19)
0.75 (19)
0.88 (22)
0.88 (22)
18 mm
18 mm
22 mm
NA
2.58 (66)
3.5 (89)
NA
2.58 (66)
3.5 (89)
NA
65 mm
89 mm
3.6 (92)
5.0 (127)
6.2 (158)
3.6 (92)
5.0 (127)
6.2 (158)
4.0 (102)
5.4 (138)
6.2 (158)
Lower Housing G
Pipe
Size
Process
Side F
1/4 NPT
1/2 NPT
H
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
4 (102)
DN 50
DN 80
DN 100
2.12 (54)
3.6 (91)
3.6 (91)
2.12 (54)
3.6 (91)
3.6 (91)
2.4 (61)
3.6 (91)
3.6 (91)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
(1) Tolerances are -0.020 and +0.040 (-0,51 and +1,02)
25
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Ordering Information
Model
Transmitter Type (Select One)
2051C
Pressure Transmitter
•
•
Model
Measurement Type
CD
CG
Differential
Gage
•
—
—
•
CD
CG
•
•
•
•
•
•
•
•
•
•
CD
CG
•
•
•
•
D
G
Code
1
2
3
4
5
Code
A
M
F
Code
2
3(1)
5
7(1)
8(1)
0
Code
4–20 mA with Digital Signal Based on HART Protocol
Low-Power, 1–5 V dc with Digital Signal Based on HART Protocol
FOUNDATION fieldbus Protocol
Materials of Construction
Process Flange Type
Flange Material
Drain/Vent
Coplanar
SST
SST
Coplanar
Cast C-276
Alloy C-276
Coplanar
Plated CS
SST
Coplanar
SST
Alloy C-276
Coplanar
Plated CS
Alloy C-276
Alternate Process Connection (Requires selecting Flange, Manifold, or Primary Element option code, see page 27)
Isolating Diaphragm
A
B
Glass-filled PTFE
Graphite-filled PTFE
1
2
Code
A
B
D
J
K(2)
M(2)
2051CG
–25 to 25 inH2O/0.5 inH2O
(–62,1 to 62,2 mbar/1,2 mbar)
–250 to 250 inH2O/2.5 inH2O
(–623 to 623 mbar/6,2 mbar)
–393 to 1000 inH2O/10 inH2O
(–0,98 to 2,5 bar/25 mbar)
–14.2 to 300 psi/3 psi
(–0,98 to 20,7 bar/0,2 bar)
–14.2 to 2000 psig/20 psi
(–0,98 to 137,9 bar/1,4 bar)
Output
316L SST
Alloy C-276
Code
26
Pressure Ranges (Range/Min. Span)
2051CD
–25 to 25 inH2O/0.5 inH2O
(–62,2 to 62,2 mbar/1,2 mbar)
–250 to 250 inH2O/2.5 inH2O
(–623 to 623 mbar/6,2 mbar)
–1000 to 1000 inH2O/10 inH2O
(–2,5 to 2,5 bar/25 mbar)
–300 to 300 psi/3 psi
(–20,7 to 20,7 bar/0,2 bar)
–2000 to 2000 psi/20 psi
(–137,9 to137,9 bar/1,4 bar)
(1)
2
3(1)
Code
CD
CG
•
•
CD
CG
•
•
•
•
•
•
•
•
•
•
•
•
CD
CG
•
•
•
•
•
•
•
•
CD
CG
•
•
•
•
CD
CG
•
•
•
•
•
•
•
•
•
•
•
•
O-ring
Fill Fluid
Silicone
Inert fill (Halocarbon)
Housing Material
Conduit Entry Size
Polyurethane-covered Aluminum
Polyurethane-covered Aluminum
Polyurethane-covered Aluminum
SST
SST
SST
½–14 NPT
M20 × 1.5 (CM20)
G½
½–14 NPT
M20 × 1.5 (CM20)
G½
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Code
Rosemount 2051
Options
CD
CG
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
—
•
•
•
—
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
(3)
Alternate Process Connection: Flange
H2
Traditional Flange, 316 SST, SST Drain/Vent
H3(1)
Traditional Flange, Cast C-276, Alloy C-276 Drain/Vent
H7(1)
Traditional Flange, 316 SST, Alloy C-276 Drain/Vent
HJ
DIN Compliant Traditional Flange, SST, 7/16 in. Adapter/Manifold Bolting
HK(4)
DIN Compliant Traditional Flange, SST, 10 mm Adapter/Manifold Bolting
HL
DIN Compliant Traditional Flange, SST, 12mm Adapter/Manifold Bolting
FA
Level Flange, SST, 2 in., ANSI Class 150, Vertical Mount
FB
Level Flange, SST, 2 in., ANSI Class 300, Vertical Mount
FC
Level Flange, SST, 3 in., ANSI Class 150, Vertical Mount
FD
Level Flange, SST, 3 in., ANSI Class 300, Vertical Mount
FP
DIN Level Flange, SST, DN 50, PN 40, Vertical Mount
FQ
DIN Level Flange, SST, DN 80, PN 40, Vertical Mount
Alternate Process Connection: Manifold(3)(5)
S5
Assemble to Rosemount 305 Integral Manifold
S6
Assemble to Rosemount 304 Manifold or Connection System
Alternate Process Connection: Primary Element(3)(5)
S4(6)
Assemble to Rosemount Primary Element
S3
Assemble to Rosemount 405 Primary Element
Diaphragm Seal Assemblies(5)
S1(7)
Assemble to one Rosemount 1199 diaphragm seal
S2(8)
Assemble to two Rosemount 1199 diaphragm seals
Mounting Brackets
B1(9)
Traditional Flange Bracket for 2-in. Pipe Mounting, CS Bolts
B2(9)
Traditional Flange Bracket for Panel Mounting, CS Bolts
B3(9)
Traditional Flange Flat Bracket for 2-in. Pipe Mounting, CS Bolts
B4(10)
Coplanar Flange Bracket for 2-in. Pipe or Panel Mounting, all SST
B7(9)
B1 Bracket with Series 300 SST Bolts
B8(9)
B2 Bracket with Series 300 SST Bolts
B9(9)
B3 Bracket with Series 300 SST Bolts
BA(9)
SST B1 Bracket with Series 300 SST Bolts
BC(9)
SST B3 Bracket with Series 300 SST Bolts
Product Certifications
E1(2)
ATEX Flameproof
E2(2)
INMETRO Flameproof
E3(2)
China Flameproof
E4(2)
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
E6
CSA Explosion-proof, Dust Ignition-proof, Division 2
E7(2)
IECEx Flameproof
EP(2)
Korea (KOSHA) Flameproof Approval
India (CCOE) Flameproof Approval
EW(2)
GOST Explosion-proof
EM(2)
ATEX Intrinsic Safety
I1(2)
I2(2)
INMETRO Intrinsic Safety
I3(2)
China Intrinsic Safety
I4(2)
TIIS Intrinsic Safety
I5
FM Intrinsically Safe, Division 2
I6
CSA Intrinsically Safe
I7(2)
IECEx Intrinsic Safety
IA(11)
ATEX FISCO Intrinsic Safety
IB(11)
INMETRO FISCO Intrinsic Safety
ID(11)
TIIS FISCO Intrinsic Safety
IE(11)
FM FISCO Intrinsically Safe
IF(11)
CSA FISCO Intrinsically Safe
•
•
•
•
•
•
27
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
IG(11)
IECEx FISCO Intrinsically Safe
IP(2)
Korea (KOSHA) Instrinsic Safety
IM(2)
GOST Intrinsically Safe
IW(2)
India (CCOE) Intrinsic Safety Approval
K1(2)
ATEX Flameproof, Intrinsic Safety, Type n, Dust
K2(2)
INMETRO Flameproof, Intrinsic Safety
K4(2)
TIIS Flameproof, Intrinsic Safety
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
K7(2)
IECEx Flameproof, Intrinsic Safety, Type n
KA(2)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KC(2)
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KD(2)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
N1(2)
ATEX Type n
N7(2)
IECEx Type n
ND(2)
ATEX Dust
DW
NSF Drinking Water Certification
Bolting Configurations
L4
Austenitic 316 SST Bolts
L5
ASTM A 193, Grade B7M Bolts
L8
ASTM A 193 Class 2, Grade B8M Bolts
Digital Display
M5
LCD display
Special Configuration (Hardware)
D4(12)
Zero and Span Hardware Adjustments
1/2-14 NPT Flange Adapters
DF(13)
(14)
D9
JIS Process Connection-RC 1/4 Flange with RC 1/2 Flange Adapter
(15)
V5
External Ground Screw Assembly
Performance
P8(16)
0.065% accuracy and 5 year stability
Terminal Blocks
T1
Transient Protection Terminal Block
Special Configuration (Software)
C1(17)
Custom Software Configuration (Requires completed Configuration Data Sheet)
C4(17)(18) Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High
CN(17)(18) Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Low
Special Procedures
P1
Hydrostatic Testing with Certificate
P2(19)
Cleaning for Special Service
P9
4500 psig (310 bar) static pressure limit (Ranges 2-5 only)
P3(19)
Cleaning for <1 PPM Chlorine/Fluorine
Special Certifications
Q4
Calibration Certificate
Q8
Material Traceability Certification per EN 10204 3.1.B
QS(17)
Prior-use certificate of FMEDA data
Q16(20) Surface finish certification for sanitary remote seals
QP
Calibration certification and tamper evident seal
QZ(20)
Remote Seal System Performance Calculation Report
Typical Model Number:
2051C D
2
A
2
2
A
1
A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
B4 M5
(1) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(2) Not available with Low Power output code M.
28
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
(3) Requires 0 code in Materials of Construction for Alternate Process Connection.
(4) Not valid with optional code P9 for 4500psi Static Pressure.
(5) “Assemble-to” items are specified separately and require a completed model number.
(6) Process Flange limited to Coplanar (codes 2, 3, 5, 7, 8) or Traditional (H2, H3, H7).
(7) Not valid with optional code D9 for RC1/2 Adaptors.
(8) Not valid with optional codes DF and D9 for Adaptors.
(9) Requires option in the Alternate Process Connection: Flange section.
(10) Requires Coplanar flange.
(11) Only valid with FOUNDATION fieldbus output code F.
(12) Not available with FOUNDATION fieldbus output code F.
(13) Not valid with Alternate Process Connection options S3, S4, S5, S6.
(14) Not available with Alternate Process Connection: DIN Flanges and Level Flanges.
(15) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(16) Available with 4-20mA HART output code A and FOUNDATION fieldbus output code F. Valid for Ranges 2-5 only.
(17) Only available with HART 4-20mA output (output code A).
(18) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(19) Not required with Alternate Process Connections S5 and S6. Include P2 option in manifold model.
(20) Requires one of the Diaphragm Seal Assemblies codes (S1 or S2).
29
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
2051T Ordering Information
Model
Transmitter Type (Select One)
2051T
In-Line Pressure Transmitter
Model
G
A
Code
1
2
3
4
5
Code
A
M
F
Code
2B
2C
2F
Code
2(1)
3(1)
Code
1
2
Code
A
B
D
J
K
M
Code
Measurement Type
Gage
Absolute
Pressure Ranges (Ranges/ Min. Span)
2051TG
–14.7 to 30 psi/0.3 psi (–1,01 to 2,1 bar/20,7 mbar)
–14.7 to 150 psi/1.5 psi (–1,01 to 10,3 bar/103,4 mbar)
–14.7 to 800 psi/8 psi (–1,01 to 55,2 bar/0,55 bar)
–14.7 to 4000 psi/40 psi (–1,01 to 275,8 bar/2,8 bar)
–14.7 to 10000 psi/2000 psi (–1,01 to 689,5 bar/138 bar)
Output
4–20 mA with Digital Signal Based on HART Protocol
Low-Power, 1–5 V dc with Digital Signal Based on HART Protocol
FOUNDATION fieldbus Protocol
Process Connection Style
1
/2–14 NPT female
G1/2 A DIN 16288 male (Range 1-4 only)
Coned and Threaded, Compatible with Autoclave Type F-250-C (Includes Gland and Collar, Available in SST for Range 5 only)
Isolating Diaphragm
316L SST
Alloy C-276
Fill Fluid
Silicone
Inert fill (Fluorinert FC-43)
Housing Material
Conduit Entry Size
Polyurethane-covered Aluminum
Polyurethane-covered Aluminum
Polyurethane-covered Aluminum
SST
SST
SST
½–14 NPT
M20 × 1.5 (CM20)
G½
½–14 NPT
M20 × 1.5 (CM20)
G½
Options
Manifold Assemblies
S5(2)
Assemble to Rosemount 306 Integral Manifold
Diaphragm Seal Assemblies
S1(2)
Assemble to one Rosemount 1199 diaphragm seal
Mounting Brackets
B4
Bracket for 2-in. Pipe or Panel Mounting, all SST
30
2051TA
0 to 30 psia/0.3 psia (0 to 2,1 bar/20,7 mbar)
0 to 150 psia/1.5 psia (0 to 10,3 bar/103,4 mbar)
0 to 800 psia/8 psia (0 to 55,2 bar/0,55 bar)
0 to 4000 psia/40 psia (0 to 275,8 bar/2,8 bar)
0 to 10000 psia/2000 psia (0 to 689,5 bar/138 bar)
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Product Certifications
E1(3)
ATEX Flameproof
E2(3)
INMETRO Flameproof
E3(3)
China Flameproof
E4(3)
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
E6
CSA Explosion-proof, Dust Ignition-proof, Division 2
E7(3)
IECEx Flameproof
EP(3)
Korea (KOSHA) Flameproof Approval
India (CCOE) Flameproof Approval
EW(3)
GOST Explosion-proof
EM(3)
ATEX Intrinsic Safety
I1(3)
I2(3)
INMETRO Intrinsic Safety
I3(3)
China Intrinsic Safety
I4(3)
TIIS Intrinsic Safety
I5
FM Intrinsically Safe, Division 2
I6
CSA Intrinsically Safe
I7(3)
IECEx Intrinsic Safety
IA(4)
ATEX FISCO Intrinsic Safety
IB(4)
INMETRO FISCO Intrinsic Safety
ID(4)
TIIS FISCO Intrinsic Safety
IE(4)
FM FISCO Intrinsically Safe
IF(4)
CSA FISCO Intrinsically Safe
IG(4)
IECEx FISCO Intrinsically Safe
IP(3)
Korea (KOSHA) Instrinsic Safety
IM(3)
GOST Intrinsically Safe
IW(3)
India (CCOE) Intrinsic Safety Approval
K1(3)
ATEX Flameproof, Intrinsic Safety, Type n, Dust
K2(3)
INMETRO Flameproof, Intrinsic Safety
K4(3)
TIIS Flameproof, Intrinsic Safety
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
K7(3)
IECEx Flameproof, Intrinsic Safety, Type n
KA(3)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KC(3)
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KD(3)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
N1(3)
ATEX Type n
N7(3)
IECEx Type n
ND(3)
ATEX Dust
DW
NSF Drinking Water Certification
Digital Display
M5
LCD display
Special Configuration (Hardware)
D4(5)
Zero and Span Hardware Adjustments
V5(6)
External Ground Screw Assembly
Performance
P8(7)
0.065% accuracy and 5 year stability
Terminal Blocks
T1
Transient Protection Terminal Block
31
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Special Configuration (Software)
C1(8)
Custom Software Configuration (Requires completed Configuration Data Sheet)
C4(8)(9)
Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High
CN(8)(9)
Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Low
Special Procedures
P1
Hydrostatic Testing with Certificate
P2(10)
Cleaning for Special Service
P3(10)
Cleaning for <1 PPM Chlorine/Fluorine
Special Certifications
Q4
Calibration Certificate
Q8
Material Traceability Certification per EN 10204 3.1.B
QS(8)
Prior-use certificate of FMEDA data
Q16(11)
Surface finish certification for sanitary remote seals
QP
Calibration certification and tamper evident seal
QZ(11)
Remote Seal System Performance Calculation Report
Typical Model Number:
2051T G 3
A
2B
2
1
A
B4 M5
(1) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(2) “Assemble-to” items are specified separately and require a completed model number.
(3) Not available with Low Power output code M.
(4) Only valid with FOUNDATION fieldbus output code F.
(5) Not available with FOUNDATION fieldbus output code F.
(6) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(7) Available with 4-20mA HART output code A and FOUNDATION fieldbus output code F. Valid for Ranges 2-5 only.
(8) Only available with HART 4-20mA output (output code A).
(9) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(10) Not valid with Alternate Process Connection S5.
(11) Requires S1 Diaphragm Seal Assembly code.
32
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
2051LLT Ordering Inform
Model
Transmitter Type
2051L
Flange-Mounted Liquid Level Transmitter
Code
2
3
4
Code
A
M
F
Code
G0
H0
A0
A2
A4
A6
B0
B2
B4
B6
C0
C2
C4
C6
D0
D2
D4
D6
Code
M
A
B
N
C
D
X
F
G
Y
H
J
Q
R
K
T
Pressure Ranges (Range/Minimum Span)
–250 to 250 inH2O/2.5 inH2O (–0,6 to 0,6 bar/6,2 mbar)
–1000 to 1000 inH2O/10 inH2O (–2,5 to 2,5 bar/25 mbar)
–300 to 300 psi/3 psi (–20,7 to 20,7 bar/0,2 bar)
Output
4–20 mA with Digital Signal Based on HART Protocol
Low-Power, 1–5 V dc with Digital Signal Based on HART Protocol
FOUNDATION fieldbus Protocol
High Pressure Side
Diaphragm Size
2 in./DN 50
2 in./DN 50
3 in./DN 80
3 in./DN 80
3 in./DN 80
3 in./DN 80
4 in./DN 100
4 in./DN 100
4 in./DN 100
4 in./DN 100
3 in./DN 80
3 in./DN 80
3 in./DN 80
3 in./DN 80
4 in./DN 100
4 in./DN 100
4 in./DN 100
4 in./DN 100
Material
316L SST
Alloy C-276
316L SST
316L SST
316L SST
316L SST
316L SST
316L SST
316L SST
316L SST
Alloy C-276
Alloy C-276
Alloy C-276
Alloy C-276
Alloy C-276
Alloy C-276
Alloy C-276
Alloy C-276
Extension Length
Flush Mount Only
Flush Mount Only
Flush Mount
2 in./50 mm
4 in./100 mm
6 in./150 mm
Flush Mount
2 in./50 mm
4 in./100 mm
6 in./150 mm
Flush Mount
2 in./50 mm
4 in./100 mm
6 in./150 mm
Flush Mount
2 in./50 mm
4 in./100 mm
6 in./150 mm
Rating
Class 150, ANSI
Class 150, ANSI
Class 150, ANSI
Class 300, ANSI
Class 300, ANSI
Class 300, ANSI
Class 150, ANSI
Class 150, ANSI
Class 150, ANSI
Class 300, ANSI
Class 300, ANSI
Class 300, ANSI
PN 10-40, DIN
PN 40, DIN
PN 10-40, DIN
PN 40, DIN
Material
CS
CS
CS
CS
CS
CS
SST
SST
SST
SST
SST
SST
CS
CS
SST
SST
Mounting Flange
Size
2 in.
3 in.
4 in.
2 in.
3 in.
4 in.
2 in.
3 in.
4 in.
2 in.
3 in.
4 in.
DN50
DN80
DN50
DN80
33
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Code
A
C
D
H
G
N
P
Code
11
21
22
2A
2B
31
Code
Process Fill-High Pressure Side
Temperature Limits
Syltherm® XLT
D.C. Silicone 704
D.C. Silicone 200
Inert (Halocarbon)
Glycerin and Water
Neobee® M-20
Propylene Glycol and Water
-100 to 300 °F (-73 to 135 °C)
60 to 400 °F (15 to 205 °C)
-40 to 400 °F (-40 to 205 °C)
-50 to 350 °F (-45 to 177 °C)
0 to 200 °F (-17 to 93 °C)
0 to 400 °F (-17 to 205 °C)
0 to 200 °F (-17 to 93 °C)
Low Pressure Side
Configuration
Gage
Differential
Differential (SST Valve Seat)
Differential
Differential (SST Valve Seat)
Remote Seal
Flange Adapter
SST
SST
SST
SST
SST
SST
O-ring
A
Glass-filled PTFE
Code
Housing Material
Conduit Entry Size
Polyurethane-covered Aluminum
Polyurethane-covered Aluminum
Polyurethane-covered Aluminum
SST
SST
SST
½–14 NPT
M20 × 1.5 (CM20)
G½
½–14 NPT
M20 × 1.5 (CM20)
G½
A
B
D
J
K
M
Code
Options
Diaphragm Seal Assembly
S1(1)
Assemble to one Rosemount 1199 diaphragm seal
Product Certifications
E1(2)
ATEX Flameproof
E2(2)
INMETRO Flameproof
E3(2)
China Flameproof
E4(2)
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
E6
CSA Explosion-proof, Dust Ignition-proof, Division 2
E7(2)
IECEx Flameproof
EP(2)
Korea (KOSHA) Flameproof Approval
India (CCOE) Flameproof Approval
EW(2)
GOST Explosion-proof
EM(2)
ATEX Intrinsic Safety
I1(2)
I2(2)
INMETRO Intrinsic Safety
I3(2)
China Intrinsic Safety
I4(2)
TIIS Intrinsic Safety
I5
FM Intrinsically Safe, Division 2
I6
CSA Intrinsically Safe
I7(2)
IECEx Intrinsic Safety
IA(3)
ATEX FISCO Intrinsic Safety
IB(3)
INMETRO FISCO Intrinsic Safety
ID(3)
TIIS FISCO Intrinsic Safety
IE(3)
FM FISCO Intrinsically Safe
IF(3)
CSA FISCO Intrinsically Safe
IG(3)
IECEx FISCO Intrinsically Safe
IP(2)
Korea (KOSHA) Instrinsic Safety
IM(2)
GOST Intrinsically Safe
34
Diaphragm Material
316L SST
316L SST
Alloy C-276
316L SST
Alloy C-276
316L SST
Sensor Fill Fluid
Silicone
Silicone
Silicone
Inert (Halocarbon)
Inert (Halocarbon)
Silicone
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
IW(2)
India (CCOE) Intrinsic Safety Approval
K1(2)
ATEX Flameproof, Intrinsic Safety, Type n, Dust
K2(2)
INMETRO Flameproof, Intrinsic Safety
K4(2)
TIIS Flameproof, Intrinsic Safety
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
K7(2)
IECEx Flameproof, Intrinsic Safety, Type n
KA(2)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KC(2)
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KD(2)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
N1(2)
ATEX Type n
N7(2)
IECEx Type n
ND(2)
ATEX Dust
DW
NSF Drinking Water Certification
Digital Display
M5
LCD display
Special Configuration (Hardware)
D4(4)
Zero and Span Hardware Adjustments
1/2-14 NPT Flange Adapters
DF(5)
(6)
V5
External Ground Screw Assembly
Terminal Blocks
T1
Transient Protection Terminal Block
Special Configuration (Software)
C1(7)
Custom Software Configuration (Requires completed Configuration Data Sheet)
C4(7)(8)
Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High
CN(7)(8)
Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Low
Special Certifications
Q4
Calibration Certificate
Q8
Material Traceability Certification per EN 10204 3.1.B
QS(7)
Prior-use certificate of FMEDA data
Q16
Surface finish certification for sanitary remote seals
QP
Calibration certification and tamper evident seal
QZ
Remote Seal System Performance Calculation Report
Flushing Connections
F1
One 1/4-inch Connector, SST Ring Material
F2
Two 1/4-inch Connectors, SST Ring Material
(9)
F3
One 1/4-inch Connector, Cast C-276 Ring Material
F4(9)
Two 1/4-inch Connectors, Cast C-276 Ring Material
F7
One 1/2-inch Connector, SST Ring Material
F8
Two 1/2-inch Connectors, SST Ring Material
F9
One 1/2-inch Connector, Cast C-276 Ring Material
F0
Two1/2-inch Connectors, Cast C-276 Ring Material
Typical Model Number:
2051L
2
A
A0 X D 21 A
A
B4
M5 F1
(1) “Assemble-to” items are specified separately and require a completed model number.
(2) Not available with Low Power output code M.
(3) Only valid with FOUNDATION fieldbus output code F.
(4) Not valid with FOUNDATION fieldbus output code F.
(5) Not available with Diaphragm Seal Assembly option S1.
(6) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(7) Only available with HART 4-20mA output (output code A).
(8) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(9) Not available with Option Codes A0, B0, and G0.
35
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
OPTIONS
Output Information
Standard Configuration
Output range points must be the same unit of measure. Available
units of measure include:
Unless otherwise specified, transmitter is shipped as follows:
Engineering Units 2051C:
Engineering Units 2051T:
Engineering Units 2051L:
4 mA (1 V dc)(1):
20 mA (5 V dc)(1):
Output:
Flange type:
Flange material:
Drain/vent:
Integral meter:
Alarm(1):
Software tag:
inH2O (Ranges 1-3), psi (Ranges 4-5)
psi (all ranges)
inH2O
0 (engineering units)
Upper range limit
Linear
Specified model code option
Specified model code option
Specified model code option
Installed or none
High
(Blank)
inH2O
inHg
mmH2O
mmHg
[email protected] °C(1)
ftH2O
[email protected] °C(1)
g/cm2
psi
bar
mbar
kg/cm2
Pa
kPa
torr
atm
(1) Not available on low power.
Hardware Adjustments
D4
Local zero and span adjustments
• Alarm and security adjustments ship standard
LCD display
M5
Digital Meter
• 2-Line, 5-Digit LCD for 4-20 mA HART and FOUNDATION fieldbus
• 1-Line, 4-Digit LCD for 1-5 Vdc HART Low Power
(1) Not applicable to fieldbus.
Tagging (3 options available)
• Standard SST hardware tag is permanently affixed on
transmitter. Tag character height is 0.125 in. (3,18 mm), 140
characters maximum.
• Tag may be wired to the transmitter nameplate upon request, 85
characters maximum.
• Tag may be stored in transmitter memory (8 characters
maximum). Software tag is left blank unless specified.
• Direct reading of digital data for higher accuracy
• Displays user-defined flow, level, volume, or pressure units
• Displays diagnostic messages for local troubleshooting
• 90-degree rotation capability for easy viewing
Transient Protection
T1
6 kV crest (0.5 μs - 100 kHz)
3 kV crest (8 × 20 microseconds)
6 kV crest (1.2 × 50 microseconds)
Commissioning tag (fieldbus only)
A temporary commissioning tag is attached to all transmitters. The
tag indicates the device ID and allows an area for writing the location.
Integral Transient Protection Terminal Block
Meets IEEE C62.41, Category Location B
Bolts for Flanges and Adapters
• Standard material is plated carbon steel per ASTM A449, Type 1
Optional Rosemount 304, 305 or 306 Integral Manifolds
Factory assembled to 2051C and 2051T transmitters. Refer to
Product Data Sheet (document number 00813-0100-4839 for
Rosemount 304 and 00813-0100-4733 for Rosemount 305 and 306)
for additional information.
Optional Diaphragm and Sanitary Seals
Refer to Product Data Sheet (document number 00813-0100-4016 or
00813-0201-4016) for additional information.
L4
L5
L8
Austenitic 316 Stainless Steel Bolts
ASTM A 193, Grade B7M Bolts
ASTM A 193 Class 2, Grade B8M Bolts
Rosemount 2051C Coplanar Flange and 2051T Bracket
Option
B4
Bracket for 2-in. Pipe or Panel Mounting
• For use with the standard Coplanar
flange configuration
• Bracket for mounting of transmitter on 2-in. pipe or panel
• Stainless steel construction with stainless steel bolts
36
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051C Traditional Flange Bracket Options
B1
Bracket for 2-in. Pipe Mounting
• For use with the traditional flange option
• Bracket for mounting on 2-in. pipe
• Carbon steel construction with carbon
steel bolts
• Coated with polyurethane paint
B2
Bracket for Panel Mounting
• For use with the traditional flange option
• Bracket for mounting transmitter on wall
or panel
• Carbon steel construction with carbon
steel bolts
• Coated with polyurethane paint
B3
Flat Bracket for 2-in. Pipe Mounting
Rosemount 2051
B7
B1 Bracket with SST Bolts
• Same bracket as the B1 option with Series 300 stainless steel
bolts
B8
B2 Bracket with SST Bolts
• Same bracket as the B2 option with Series 300 stainless steel
bolts
B9
B3 Bracket with SST Bolts
• Same bracket as the B3 option with Series 300 stainless steel
bolts
BA
Stainless Steel B1 Bracket with SST Bolts
• B1 bracket in stainless steel with Series 300 stainless steel
bolts
BC
Stainless Steel B3 Bracket with SST Bolts
• B3 bracket in stainless steel with Series 300 stainless steel
bolts
• For use with the traditional flange option
• Bracket for vertical mounting of transmitter on 2-in. pipe
• Carbon steel construction with carbon
steel bolts
• Coated with polyurethane paint
37
Product Data Sheet
00813-0100-4101, Rev BA
February 2009
Rosemount 2051
Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Rosemount, Annubar, ProPlate, and the Rosemount logotype are registered trademarks of Rosemount Inc.
PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.
Complete Point Solutions, Coplanar and Multivariable are trademarks of Rosemount Inc.
HART is a registered trademark of the HART Communications Foundation..
Syltherm 800, Dow Corning, and D.C. are registered trademarks of Dow Corning Co.
Neobee M-20 is a registered trademark of Stephan Chemical Co.
The 3-A symbol is a registered trademark of the 3-A Sanitary Standards Symbol Council.
FOUNDATION fieldbus is a registered trademark of the Fieldbus Foundation.
Fluorinert is a registered trademark of 3M Company.
© 2009 Rosemount, Inc. All rights reserved.
All other marks are the property of their respective owners.
Rosemount 2051 Smart Pressure Transmitters may be protected by one or more of the following U.S. Patent Nos. 4926340, 5028746,
5248167, 5278543, 5287746, 5329818, 5333504, 5495768, 5585777, 6017143, 6119047, and 6295875. Other foreign patents issued and
pending.
Emerson Process Management
Rosemount Measurement
8200 Market Boulevard
Chanhassen MN 55317 USA
Tel (USA) 1 800 999 9307
Tel (International) +1 952 906 8888
Fax +1 952 949 7001
00813-0100-4101 Rev BA, 02/09
Emerson Process Management
Blegistrasse 23
P.O. Box 1046
CH 6341 Baar
Switzerland
Tel +41 (0) 41 768 6111
Fax +41 (0) 41 768 6300
Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465
Emerson Process Management Asia Pacific
Pte Ltd
1 Pandan Crescent
Singapore 128461
Tel +65 6777 8211
Fax +65 6777 0947
Service Support Hotline : +65 6770 8711
Email : [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement