DIGISMART™ PTAC
DIGISMART™ PTAC
PACKAGED TERMINAL AIR
CONDITIONER AND HEAT PUMP
PRODUCT SPECIFICATIONS
We have designed the Amana® brand Packaged
Terminal Air Conditioner for customer comfort and
owner piece of mind. No other unit in the industry
offers so many energy management features as
standard. With the ability of the DigiSmart™ PTAC to
reduce operating costs by 35%, there is no need to
settle for anything less than an Amana® brand PTAC.
Features
• Energy Efficiency — Amana® brand PTACs have an EER
of up to 12.8 (on heat pumps, a COP of up to 3.6) to
keep energy consumption to a minimum
• On-board Energy Management System — Amana®
brand units are equipped with EMS technology to
better control room temperature and save energy
dollars
• DigiSmart™ Control Board — ready for wireless or
wired operation
WITH
DIGISMART™ CONTROL BOARD
• Programmable Set-back Program — owner-controlled
settings allows automatic temperature setback when
unit is idle
• Network Ready — Amana® brand DigiSmart™ units
connected to a Tridium JACE controller automatically
build their own wireless network
• DigiSmart™ Suite of Peripherals — remote occupancy
sensor, remote thermostat, RF antennas, and RF platform controller provide everything you need to reduce energy costs by 35%
FULL WARRANTY
• 1ST YEAR
• 2ND THROUGH 5TH YEAR —
SEALED SYSTEM
ARI (Air Conditioning & Refrigeration Institute)
Standards 310/380
Underwriters Laboratories
USA and Canada
SS-DPTAC
LIMITED WARRANTY
• 2ND THROUGH 5TH YEAR — PARTS
Canadian Standards
Association
EEV Certification Programs
www.amana-ptac.com
6/07
Supersedes 1/07
Specification Sheet
DIGISMART™ SYSTEM
The Amana® DigiSmart™ suite of products work together to let you control and monitor each air conditioning unit.
IN-ROOM PRODUCTS
A PTAC — The PTAC itself contains all the processing power and software to manage energy
consumption, unit status, and comfort performance.
B Occupancy Control — The remote sensor above the door determines if the room is occupied
or not. If occupied, normal routines run, but if unoccupied the PTAC can change temperature settings based upon configurations set by owner.
C Remote Thermostat — The DigiSmart™ remote thermostat works just like the one at home
but unlike other PTACs does not disable the unit’s own controls. Remote and PTAC control
panels work at the same time and show the same information.
• Set-up — Best of all, no wiring. All of the peripheral devices can be installed by your handy
man without calling an expensive electrician. A touch of a button connects the peripherals
to the air conditioner in that room.
B
C
A
PROPERTY-WIDE NETWORK
• The Tridium Jace™ controller connects all Amana® DidgSmart™ PATCs in a property automatically through a self-detection routine.
• Once connected to your PC, the status and operating condition of each unit can be viewed remotely and its settings
changed.
• The Tridium Jace™ controller through its NiagaraAX protocol has already built connections to more than 100 commercially available building management systems. So once the network is up and running, Amana® PTACS can be integrated
with your existing building management system or if desired, controlled remotely through the internet.
For more information, go to www.amana-ptac.com.
PRODUCT FEATURES
On-Board Energy Management System (EMS)
• Set-Back Mode — the owner can determine amount of time unit is left ‘untouched’
(buttons not pushed) before the PTAC begins a set-back routine and new thermostat
temperature takes effect. All set-back routines can be changed by owner.
• Maintenance Status — Separate green LED indicator light to show if unit requires
maintenance
• Electronic Temperature Limits – owner can set separate cooling and heating temperaMaintenance
ture ranges and limit operation to one-degree increments, saving energy by preventIndicator Light
ing guests from over-cooling or over-heating.
• Enhanced Dehumidification Cooling Mode — the unit can be set to lengthen cooling cycles while the room is occupied
or unoccupied. This passes more air through the unit while the coil is below the dew point, increasing the amount of
moisture removed.
• Unit Diagnostics — when switched to diagnostics mode, the unit shows ten different self-diagnosis codes to help keep
the unit running most efficiently.
• Freeze Protection — when sensors show an outdoor temperature of 40ºF or below, the unit automatically activates the fan
motor and the electric or hydronic heat to help prevent burst water pipes or broken fixtures caused by freezing temperatures.
• Extended Heating with the Heat-Pump — heat pump models will operate in heat-pump mode with external temperatures
as low 24ºF to provide additional energy savings.
• 30-Second Fan-Off Delay — the fan continues to run for 30 seconds after the compressor has stopped or after electric
heat has been turned off. This improves efficiency by dispersing the cooled or heated air still on the coil into the room.
2
www.amana-ptac.com
SS-DPTAC
SPECIFICATION SHEET
EMS ACCESSORIES (@ WWW.AMANA-PTAC.COM)
DD01A — DIGIDOOR: WIRELESS RF OCCUPANCY SENSOR
The DigiDoor is a combination door switch and room motion sensor powered by 2 AAA batteries that are included in the kit.
Once wirelessly linked to an Amana® brand DigiSmart™ PTAC, the DigiDoor monitors room occupancy and automatically
activates the Energy Management System (EMS) temperature set-back function.
You can further refine your EMS programming by configuring the DigiSmart with up to 100,000 EMS set-back combinations,
either through the DigiSmart touch-pad or wirelessly through the optional DigiTenna DT01A and DP01A Gateway.
The DigiTenna (DT01A) is required for the DigiDoor to communicate to the DigiSmart PTAC
DP01A — DIGIPLATFORM: WEB-ENABLED PLATFORM CONTROLLER
The DigiPlatform uses standard 115-volt power and communicates by antennae to each Amana® brand DigiSmart ™ PTAC
with a DigiTenna (DT01A) on an encrypted 2.4 GHz signal using the 802.15 Zigbee standard.
All DigiSmart™ suite of peripherals linked to a DigiSmart™ PTAC can be monitored, controlled, and upgraded easily
through the DigiPlatform wireless RF network.
Because it is Web-enabled, all DigiPlatform functions can be accessed through the Amana® brand Hotel Link software
contained in the DigiPlatform.
The DigiPlatform has several other software applications embedded in the device that allow optional connectivity to a
property management system to monitor room rental status. Optional drivers and/or software are required.
Being BACnet- and LAN-compliant allows the DigiPlatform to integrate with almost every property controller available
in the industry today. The DigiPlatform allows operational monitoring of each PTAC and peripheral device. Additional
optional software may be required.
DS01B — DIGISTAT” RF WIRELESS REMOTE-MOUNTED THERMOSTAT
The DigiStat is a remote wall-mounted thermostat that can control the Amana® brand DigiSmart™ PTAC from anywhere
in the room. It is powered by 2 AAA batteries that are included in the kit.
The DigiStat communicates on a two-way RF encrypted signal. Settings can be changed either at the DigiStat or on the
PTAC at the DigiSmart touch-pad. Settings are automatically relayed to the other device within moments.
A DigiTenna (DT01A) is required for the DigiStat to communicate with the DigiSmart PTAC.
DSUK01B — DIGISMART CONTROL BOARD UPGRADE KIT
Any Amana® brand Series A or Series B PTAC produced since 1996 can be upgraded with a DigiSmart™ control board.
The DSUK01B is a field-installation kit to convert an older ‘knob control’ Amana® brand PTAC to the new DigiSmart™ LED control.
The converted Amana® brand PTAC has the same energy management system as a DigiSmart™ PTAC and can connect to
the DigiSmart™ suite of peripheral devices.
DT01A — DIGITENNA: WIRELESS RF GATEWAY TRANSCEIVER ANTENNA
The DigiTenna mounts inside the Amana® brand DigiSmart PTAC, hidden from sight. It is powered through PTAC and requires no
batteries. It is required for any of the DigiSuite RF wireless devices to communicate with the Amana® brand DigiSmart PTAC.
The DigiTenna communicates to any of the Amana DigiSmart suite of devices via an encrypted 2.4 Ghz signal using the
802.15 Zigbee standard. Some Amana® brand DigiSmart PTACs may require upgrades to the latest DigiSmart software to
allow RF devices to be linked to the control.
For use with: DD01A and DS01B, both required parts of package
REMOTE ENERGY MANAGEMENT SYSTEMS (EMS) READY
An 18-pin low-voltage connector links the unit to many wired energy management systems (EMS). The control board
has low-voltage terminals for a wired room motion sensor, a door switch, or a remote-mounted thermostat. Two serial
communication ports also allow for future communications capability to many other types of Amana-approved wireless
RF peripheral devices.
REMOTE THERMOSTAT-READY
The unit has an 18-pin connector with seven dedicated low-voltage terminals for easy connection to a wide variety
of remote wired thermostats. The unit’s off-board 20-va transformer has enough power to supply energy to most
commercially available thermostats. Also, the unit can be configured to be used with either a “B” or an “O” terminal,
further increasing the types of thermostats that can be connected to the unit.
SS-DPTAC
www.amana-ptac.com
3
Specification Sheet
PTAC ACCESSORIES (MORE @ WWW.AMANA-PTAC.COM)
CONDENSATE DRAIN KIT
Attaches to the wall sleeve base pan for controlled internal or external
disposal of condensate.
DK900D
161/16"
WALL SLEEVE 14⅛” (D) X 42” (W) X 161/16” (H)
Our insulated, Stonewood Beige metal sleeves with industrystandard dimensions are shipped with a weather board
for use during construction. The WS900D is an industrystandard depth of 14⅛”. The extra-deep sleeves can be
custom ordered starting at 16” to 24” (D) in 1” increments.
Sleeves may be shipped separately to allow for installation
during construction.
DK900D
42"
14
WS900D
Standard 14 ” Depth
WS9**D1
Extra Deep (16” to 24”)
"
DK9001D
Condensate Drain Kit (use with WS900D)
Condensate Drain Kit (use with WS900B & extra
deep wall sleeves)
** Depth in inches
OUTDOOR GRILLES
CONDENSER BAFFLE KIT
Available in stamped aluminum or architecturally louvered for application For use on non-baffled grilles. These deflectors direct the air in toward
with a WS900D wall sleeve.
the center and away from the inlet to prevent recirculation of the hot
AGK — Extruded aluminum architectural grille available with condenser air.
anodized aluminum finish and a baked-on paint finish for
Condenser Baffles
durability. Choose from three stock colors or a custom color.
PGK — One-piece injection molded grille using a polymer
blend of engineered thermoplastic high-impact strength
Condenser
material with chemical resistance and an exterior UV
protective coating. Choose from three stock colors.
Basepan
Colors:
DGK1B
Condenser Baffle Kit
DB (Dark Brown/Bronze), TB (Stonewood Beige), WB (White),
SB (Special/Custom Colors)
WIRE HARNESS KIT
For quick connections of the remote thermostat or front desk with
jumpers and connectors.
PWHK01C
AGK
or
PGK
Wire Harness Kit
STC 30 RATING ACCESSORY KIT
Raises sound ratings from 27 to 30 to meet or exceed most sound test
requirements.
Standard Outdoor Grille
SGK01B
STC101A
10 Pack
Single Pack
Architectural Grille
AGK01*B
Single Pack
PGK01*B
Single Pack
SECURITY KEY LOCKS
SUB-BASE EXTENSION COVER KIT
In conjunction with the tamper-resistant front, the installation of Converts older 30-amp sub-bases to allow for installation of
Amana® brand security key locks prevents tampering of the controls the larger 30-amp LCDI power cord and plugs.
used to set temperature, heating and cooling functions. UL approved
SBEC10A 10 Pack
for institutional use only.
KL03B
4
Security Key Lock
www.amana-ptac.com
SS-DPTAC
SPECIFICATION SHEET
ACCESSORIES (CONT.)
POWER VENT KIT (NOT SHOWN)
POWER DOOR KIT (NOT SHOWN)
Installation of Power Vent increases CFM up to approximately 95. Vent Vent door will automatically open when unit fan is on.
door will automatically close when unit fan is off.
PVK3A
PVK4A
PDK3A
PDK4A
230/208V
265V
FUSE HOLDER KIT
•
Cartridge-style fuses can be installed in the fuse holder for use in
the sub-base or chassis. Available in 15, 20 and 30 amp (included on
265-volt unit).
FHK315C
FHK320C
FHK330C
230/208V
230/208V
230/208V
230/208V
265V
Circuit Breaker Kit (230/208V only)
The circuit breaker kit, available in 15, 20 or 30 amp, can be used
with Amana® brand sub-bases. It gives overcurrent protection, and its
location allows you to turn the unit on or off without tools.
15A
20A
30A
CBK3**C
Circuit Breaker Kit
SUB-BASE KIT
THERMOSTATS
The fully skirted sub-base conceals wiring while providing strong The following thermostats offer remote control. Any thermostat other
support, if needed. Plug-in receptacle and field-wiring access speeds than those listed must be submitted to Goodman Company, L.P., for
installation. Electrical accessories, such as fuse holders, circuit breakers approval prior to use.
and disconnect switches, meet N.E.C. requirements.
Optional
Fuse Holder
Location
Optional
Power Switch and Circuit Breaker
Location
Power Receptacle
Skirting
Skirting
MODEL
Leveling Legs
HEAT
COOL
DISPLAY
STAGES STAGES
TYPE
SHAPE &
ORIENTATION
Subbase Box Assembly
C5200609
1*
1
Mech.
Manual
Round
PTSB320E
230/208V
15/20A
D9945801
2**
1
Mech.
Manual
Rect./Horiz.
PTSB330E
230/208V
30A
1246005/6
1*
1
Mech.
Manual
Rect./V or H
PTSB420E
265V
15/20A
1246001
1*
1
Digital
Manual
Rect./Horiz.
PTSB430E
265V
25A
1246003
2**
1
Digital
Manual
Rect./Horiz.
1246004
2**
1
Digital
Program
Rect./Horiz.
1241501
2**
1
Digital
Auto Change
Rect./Vert.
PTSB000E
Non-electrical
* PTC Models Only
** PTC and PTH Models
SS-DPTAC
www.amana-ptac.com
5
Specification Sheet
ACCESSORIES (CONT.)
HARD-WIRE KIT (NOT SHOWN)
POWER DISCONNECT SWITCH (NOT SHOWN)
Used to permanently wire to the chassis when a standard sub-base The PSHW**A power disconnect switch can be used for 265-volt or
and power cord are not utilized.
230/208-volt physical disconnect, where required by local codes. The
switch is rated at 30-amp capacity. The switch is for use with and
PTPWHWK4
Hard Wire Kit
Amana® brand standard sub-bases or PTPWHWK4 Hard Wire Kit.
PSHW03A
230/208V
PSHW04A
265V
CONDENSATE REMOVAL PUMP
SPARE FILTERS
Can be field installed. Assists in removing condensate developed by heat Helps keep dirt and lint out of the air and off the coil, thus increasing
pump operation and transfers it to indoor coil to dissipate into room the unit's efficiency. Amana® brand filters are easy to remove, wash
and replace.
while adding humidity to the room.
CDP302
CDP402
230/208V
265V
FK10A
FK10B
REPLACEMENT CHARCOAL FILTER KIT
Filters (10-pack) - A Series
Filters (10-pack) - B Series
HEATER KIT—FOR HEATER-LESS UNITS ONLY
Absorbs airborne odors caused by cigarette, pipe or cigar smoke and Optional 1.5 kW heater kits are available for use only with models
odors caused by mold, mildew, etc. Filters are made of polyester fibers originally shipped without electric heat. Ask salesperson for details.
coated with activated charcoal and are individually wrapped. This
Model Nominal BTUs
230V 208V 265V
filters are permanent and can be washed or cleaned. Call your Amana®
Rated Watts
All
1,500 1,200 1,500
brand PTAC sales person for details. 10 filters per pack.
CFK10A
Charcoal Filters (10-pack) - A Series
Full Load Amps
(incl. fan)
CFK10B
Charcoal Filters (10-pack) - B Series
Min. Ampacity
Fuse Size
HYDRONIC HEAT KIT
Add-on kits fit all units allowing the addition of hydronic water or
hydronic steam heat to cooling and heating units. The kits feature
left- or right-hand piping. Unit retains complete service access with a
kit installed. Unit must be connected to and operated by a wall
thermostat.
6.9
7.1
8.6
8.8
15
6.2
6.4
8.6
8.8
15
6.1
6.3
7.5
7.7
15
DUCT EXTENSION KIT
Extends air distribution to an adjoining room. Consists of a main duct
for the room of origin and an extension duct to reach the adjoining
room and terminal duct. PTDK01A allows for the new “B” series unit to
work with the “A” series duct kits.
Hydronic Heat Kit-Top View
5-1/2"
7K & 9K
12K & 15K
7K & 9K
12K & 15K
All
Main Duct Kit
Terminal Duct Kit
1-7/8"
PTAC UNIT WALL SLEEVE
3-1/4"
3-1/4"
1-7/8"
15/32"
2 places
TRANSITION
BAFFLES
2-3/4"
2 places
Hydronic Air
Discharge
Unit Controls
Compartment
Hot Water Inlet / Outlet Connections
Steam
Inlet
/ Outlet Connection
Outlet
Connection
Extension Duct Kit
Hydronic Heat Kit-Side View
Hydronic Heat Kit-Right View
3" +1/8"
-0"
Steam/Water
Coil Position
Top of Wall Sleeve
8-1/4"
20-3/16"
2-1/8"
10-13/16"
Toe Plate
0" - 3.0" Long
53"
Hydronic Air
Inlet
6
Hydronic Front
Wall Sleeve
Hot Water Inlet / Outlet Connections
SteamSteam
Inlet /Inlet
Outlet Connections
16-3/4"
4-1/8"
Bottom of Wall Sleeve
HWK03B
Hydronic Water Kit
HVK03B
Hydronic Steam Kit
www.amana-ptac.com
MDK02B
Main Duct
EDK02B
Extension Duct
TDK02
Terminal Duct
PTDK01A
Transition Duct Only
SS-DPTAC
SPECIFICATION SHEET
ACCESSORIES (CONT.)
HYDRONIC VALVES (NOT SHOWN)
HYDRONIC TRANSFORMER RELAY KIT (NOT SHOWN)
Water and steam valves are available for use with the HWK03 (water) Add-on kit that allows field conversion of a standard PTC unit to a
and HVK03 (steam) heat kits. (See Architects and Engineers Manual for hydronic unit.
specifications.)
VS2WNCA*
2-way/24V/NC/Steam
VS2WNOA*
2-way/24V/NO/Steam
VW2WNCA*
2-way/24V/NC/End Switch
VW2WNOA*
2-way/24V/NO/End Switch
VW3WNC2B*
3-way/24V/NC/NO/End Switch
HTK3A
230/208V
HTK4A
265V
REMOTE ESCUTCHEON KIT (NOT SHOWN)
Optional kit for use with units controlled via a wired, remote
thermostat. Covers control touch-pad for wired thermostat
installations.
* Pop-top Actuator
REK10B
Remote Escutcheon Kit (10pack)
Each kit contains 80 wires and wire nuts, enough to attach a thermostat
and one additional accessory to 10 PTAC units. Wires come in assorted
colors for easy attachment.
PULL-OUT EASY ACCESS FILTER
Maintaining the unit’s efficiency while saving time and money is easy. The filter is easily accessed for cleaning or
replacement without removing the unit front.
Step 2: Pull the filter up and out.
Step 1: Open the intake grille louver.
SS-DPTAC
www.amana-ptac.com
7
Specification Sheet
PRODUCT SPECIFICATIONS
PTC MODELS — COOLING/ELECTRIC HEAT
MODEL 1, 7, 9, 10, 12
VOLTAGE ¹, 3, ¹¹
CAPACITY
(BTU/H)
M MODELS
N MODELS
AMPS¹²
PTC
073B**A-
PTC
074B**A-
PTC
093B**AM
PTC
094B**AM
PTC
123B**AM
PTC
124B**AM
PTC
153B**AM
PTC
154B**AM
230/208
265
230/208
265
230/208
265
230/208
265
M = 7,100
9,100/
8,900
9,100
12,000/
11,900
12,000
14,000/
13,900
14,000
N = 7,300
N/A
N/A
N/A
N/A
N/A
N/A
2.3
3.7/3.8
3.0
4.6/5.0
4.3
6.3/6.9
5.9
1,130
1,470/
1,450
1,470
M= 7,100/
6,900
N= 7,400/
7,300
2.8/3.0
610/595
610
790/775
790
1,110/
1,100
M MODELS
M= 11.6/11.6
M = 11.6
11.5
11.5
10.8
10.8
9.5
9.5
N MODELS
N= 12.4/12.8
N = 12.4
N/A
N/A
N/A
N/A
N/A
N/A
4.0
3.6
5.1
4.4
6.4
5.7
8.8
7.7
WATTS¹²
EER
UNIT WITHOUT ELECTRIC HEATER
MIN. CIRCUIT AMPS 2,
4, 12
CFM
(COOL/WET
COIL)
HIGH
245/240
245
245/240
245
325/315
325
325/315
325
LOW
220/205
220
220/205
220
250/229
250
250/220
250
CFM (DRY
COIL)
HIGH
265/260
265
265/260
265
345/335
345
345/335
345
LOW
230/215
230
230/215
230
265/235
265
265/235
265
65*
65*
65*
65*
70*
70*
70*
70*
65*
65*
65*
65*
70*
70*
70*
70*
1.6
1.6
2.6
2.6
3.5
3.5
4.4
4.4
NET WEIGHT (LBS.)
90
90
95
95
105
105
110
110
SHIPPING WEIGHT (LBS.)
105
105
110
110
120
120
125
125
VENTILATED AIR, CFM
(FAN ONLY)*
VENTILATED AIR, CFM
(COMPRESSOR & FAN)*
DEHUMIDIFICATION
(PINTS/HR.)
- Denotes M or N models
* Approximately 95 CFM with optional power vent kit. Actual vent CFM performance will vary due to application and installation conditions.
NOTES:
1– All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
2– Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
3– Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
Minimum voltage on 265-volt models is 238.5 volts; maximum is 291.5 volts.
4– Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style
time-delay fuses (included and factory-installed on all Amana® brand 265-volt chassis). See heater performance for total MCA.
5– Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat
at approximately 24°F outdoor ambient.
6– Total watts for 12,000 and 15,000 BTU/h models; subtract 70 watts for PT07/09*B**A*
7– Specify two-digit heater kW size to complete model number.
8– Total amps for 12,000 and 15,000 BTU/h models; subtract 0.2 amps for PT07/09*B*A*.
9– R-22 refrigerant used in all systems.
10– All units meet or exceed ASHRAE 90.1 standards.
11– All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
12– Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
8
www.amana-ptac.com
SS-DPTAC
SPECIFICATION SHEET
PRODUCT SPECIFICATIONS (CONT.)
PTC AND PTH MODELS — ELECTRIC HEAT PERFORMANCE
(Primary Heating for PTC Models; Auxiliary Heating for PTH Models; See below for Power Cord Configuration)
ELECTRIC
HEATER SIZE
(KW)
NO. OF
STAGES
230/208V
2.5/2.0
230/208V
230/208V
VOLTAGE
NOMINAL HEATING (BTU/H)
TOTAL
WATTS6
TOTAL AMPS8
MINIMUM
CIRCUIT
AMPACITY²
MOD4
(AMPS)
POWER
CORD
@ 230V
@ 208V
@ 265V
1
8,500
6,800
--
2,650/2,140
11.5/10.2
14.2
15
6 - 15 P
3.5/2.9
1
12,000
9,900
--
3,650/3,040
15.8/14.5
19.6
20
6 - 20 P
5.0/4.1
1*
17,100
14,000
--
5,150/4,240
22.3/20.3
27.7
30
6 - 30 P
265V
2.5
1
--
--
8,500
2,650
10.0
12.4
15
7 - 20 P
265V
3.7
1
--
--
12,600
3,850
14.6
18.1
20
7 - 20 P
265V
5.0
1*
--
--
17,100
5,150
19.5
24.2
25
7 - 30 P
* PTH/PTC09*B50*G/K has the same airflow as a PTC/PTH12*B***G (not available on 7,000 BTU/h models).
NOTES:
1– All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
2– Minimum branch circuit ampacity ratings conform to the National Electric Code; however, local codes should apply.
3– Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
Minimum voltage on 265-volt models is 238.5 volts; maximum is 291.5 volts.
4– Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style
time-delay fuses (included and factory-installed on all Amana® brand 265-volt chassis).
5– Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat
at approximately 24°F outdoor ambient.
6– Total watts for 12,000 and 15,000 BTU/h models; subtract 70 watts for PT07/09*B**A*
7– Specify two-digit heater kW size to complete model number.
8– Total amps for 12,000 and 15,000 BTU/h models; subtract 0.2 amps for PT07/09*B*A*.
9– R-22 refrigerant used in all systems.
10– All units meet or exceed ASHRAE 90.1 standards.
11– All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
POWER CORD CONFIGURATION
Power Cord Plugs
Power Receptacle Configuration
250V Rating Power Cord Plugs with LCDI Device
NEMA 6 Configuration
G
NEMA6-15R; 250V receptacle,
used on 230/208V units
G
NEMA6-20R; 250V receptacle,
used on 230/208V units
G
20 amp
15 amp
30 amp
277V Rating Power Cord Plugs
NEMA 7 Configuration
G
20 amp
SS-DPTAC
G
G
W
W
G
W
30 amp
www.amana-ptac.com
NEMA6-30R; 250V receptacle,
used on 230/208V units
NEMA7-20R; 277V receptacle,
used on 265V units
NEMA7-30R; 277V receptacle,
used on 265V units
All units come with factory-installed power cords.
All units less than 250 volts come with LCDI device.
9
Specification Sheet
PRODUCT SPECIFICATIONS (CONT.)
PTH MODELS — COOLING/HEAT PUMP/ELECTRIC HEAT
MODEL 1, 7, 9, 10, ¹²
VOLTAGE 1, 3, 11
CAPACITY
(BTU/H)
M MODELS
N MODELS
PTH073B**A-
PTH
074B**A-
PTH
093B**AM
PTH
094B**AM
PTH
123B**AM
PTH
124B**AM
PTH
153B**AM
PTH
154B**AM
230/208
265
230/208
265
230/208
265
230/208
265
M=7,000
9,100/
8,900
9,100
12,000/
11,800
12,000
14,000/
13,900
14,000
N=7,300
N/A
N/A
N/A
N/A
N/A
N/A
M=7,000/
6,800
N=7,400/
7,300
AMPS
2.8/3.0
2.3
3.5/3.8
3.0
4.6/5.0
4.3
6.3/6.9
5.9
WATTS¹²
605/585
605
790/775
790
1,110/1,090
1,110
1,505/1,495
1,505
M MODELS
M=11.6/11.6
M=11.6
11.5
11.5
10.8
10.8
9.3
9.3
N MODELS
N=12.4/12.8
N=12.4
N/A
N/A
N/A
N/A
N/A
N/A
4.0
3.6
5.1
4.4
6.4
5.7
8.8
7.7
HIGH
245/240
245
245/240
245
325/315
325
325/315
325
LOW
220/205
220
220/205
220
250/229
250
250/220
250
HIGH
265/260
265
265/260
265
345/335
345
345/335
345
LOW
230/215
230
230/215
230
265/235
265
265/235
265
EER
UNITS WITHOUT ELECTRIC HEATER
MCA ², 4, ¹²
CFM
(COOL/WET COIL)
CFM (DRY COIL)
VENTILATED AIR, CFM
(FAN ONLY)*
VENTILATED AIR, CFM
(COMPRESSOR AND FAN)*
DEHUMIDIFICATION
(PINTS/HR.)
65*
65*
65*
65*
70*
70*
70*
70*
65*
65*
65*
65*
70*
70*
70*
70*
1.6
1.6
2.6
2.6
3.5
3.5
4.4
4.4
NET WEIGHT (LBS.)
95
95
100
100
110
110
115
115
SHIPPING WEIGHT (LBS.)
110
110
115
115
125
125
130
130
- Denotes M or N models
* Approximately 95 CFM with optional power vent kit; actual vent CFM performance will vary due to application and installation conditions.
** EER = Energy Efficiency Rating per Air Conditioning & Refrigeration Institute (ARI) and Canadian Standards Association (CSA) EEV Test
Procedures.
NOTES:
1– All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
2– Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
3– Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
Minimum voltage on 265-volt models is 238.5 volts; maximum is 291.5 volts.
4– Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style
time-delay fuses (included and factory-installed on all Amana® brand 265-volt chassis). See heater performance for total MCA.
5– Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat
at approximately 24°F outdoor ambient.
6– Total watts for 12,000 and 15,000 BTU/h models; subtract 70 watts for PT07/09*B**A*
7– Specify two-digit heater kW size to complete model number.
8– Total amps for 12,000 and 15,000 BTU/h models; subtract 0.2 amps for PT07/09*B*A*.
9– R-22 refrigerant used in all systems.
10– All units meet or exceed ASHRAE 90.1 standards.
11– All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
12– Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to
compressor only.
10
www.amana-ptac.com
SS-DPTAC
SPECIFICATION SHEET
PRODUCT SPECIFICATIONS (CONT.)
PTH MODELS — REVERSE-CYCLE HEATING PERFORMANCE
HEATING CAPACITY¹
M MODELS
BTU/H
5
N MODELS
PTH 073B**AM=6,200/
6,000
N=6,400/
6,300
PTH
074B**A-
PTH
093B**AM
PTH
094B**AM
PTH
123B**AM
PTH
124B**AM
PTH
153B**AM
PTH
154B**AM
M = 6,200
8,200/ 8,000
8,200
10,800/
10,600
10,800
13,300/
13,200
13,300
N = 6,200
---
---
---
---
---
---
AMPS¹²
2.6/ 3.0
2.2
3.2/ 3.6
2.6
4.5/ 5.1
3.9
5.7/ 6.3
5.4
WATTS¹²
550/ 530
550
750/ 730
750
1,020/ 1,000
1,020
1,340/ 1,330
1,340
M MODELS
M= 3.3/ 3.3
M = 3.3
3.2
3.2
3.1
3.1
2.9
2.9
N MODELS
N= 3.5/ 3.6
N = 3.5
---
---
---
---
---
---
235/ 230
235
235/ 230
230
310/ 290
310
345/ 335
345
COP5
CFM (DRY)
HEATING
(BTU/H)5
OUTDOOR
AMBIENT
RATING
POINT
WATTS
OUTDOOR
AMBIENT
13,000/
12,800
12,300/
12,100
11,600/
11,400
10,800/
10,600
13,000
15,800/
15,700
15,000/
14,900
14,200/
14,100
13,300/
13,200
62 °F
7,200/ 7,000
7,200
9,800/ 9,600
9,800
57 °F
6,900/ 6,700
6,900
9,300/ 9,100
9,300
52 °F
6,500/ 6,300
6,500
8,700/ 8,500
8,700
47 °F
6,200/ 6,000
6,200
8,200/ 8,000
8,200
COP*
3.3/ 3.3
3.3
3.2/ 3.2
3.2
3.1/ 3.1
3.1
42 °F
5,900/ 5,700
5,900
7,700/ 7,500
7,700
10,100/
9,900
10,100
37 °F
5,600/ 5,400
5,500
7,200/ 7,000
7,200
9,400/ 9,200
9,400
32 °F
5,300/ 5,100
5,200
6,700/ 6,500
6,700
8,600/ 8,400
8,600
27 °F
5,000/ 4,800
5,000
6,200/ 6,000
6,200
7,900/ 7,700
7,900
24 °F
4,800/ 4,600
4,800
5,900/ 5,700
5,900
7,500/ 7,300
7,500
9,500/ 9,400
9,500
62 °F
580/ 560
580
810/ 790
810
1,120/ 1,100
1,120
1,465/ 1,455
1,465
57 °F
575/ 555
575
800/ 780
800
1,090/ 1,075
1,090
1,440/ 1,430
1,440
52 °F
555/ 535
555
775/ 755
775
1,060/ 1,045
1,060
1,405/ 1,395
1,405
47 °F
550/ 530
550
750/ 730
750
1,020/ 1,005
1,020
1,340/ 1,330
1,340
42 °F
540/ 525
560
730/ 710
730
985/ 970
985
1,325/ 1,315
1,325
37 °F
530/ 515
545
705/ 685
705
950/ 935
950
1,285/ 1,275
1,285
32 °F
515/ 500
535
690/ 670
690
900/ 885
900
1,240/ 1,230
1,240
27 °F
505/ 490
525
660/ 640
660
855/ 840
855
1,190/ 1,180
1,190
24 °F
500/ 485
520
640/ 620
640
830/ 815
830
1,180/ 1,170
1,180
12,300
11,600
10,800
2.9/ 2.9
12,500/
12,400
11,700/
11,600
10,800/
10,700
10,000/
9,900
15,800
15,000
14,200
13,300
2.9
12,500
11,700
10,800
10,000
- Denotes M or N models
COP = Coefficiency of Performance; per ARI Test Procedures, units are rated for capacities and efficiencies.
See Page 6 for Notes and Auxiliary Electric Heater Performance.
SS-DPTAC
www.amana-ptac.com
11
Specification Sheet
CONTRACT BID SPECIFICATIONS
Ratings
Unit Digital Controls
Each unit must meet the following specifications:
ARI rating of ________BTU/h cooling (and ______ BTU/h
reverse cycle heating with a COP of ________ at 47° F O.D.)
Electric resistance heat of _________ BTU/h. Total Amp draw
must be of _______ and ______ Watts at ______ volts.
The unit must remove a minimum of _________ pints of
moisture per hour when operated at rating conditions. The
EER must be a minimum of _________ EER.
Unit control must be completely wired and accessible from
the top of the chassis. Controls shall be an LED touch-pad
design with six large, easy-to-read and use buttons: Heat –
Cool – Off – Fan – Temp+ (plus) – Temp- (minus) and two red
seven-segment LED temperature displays. Unit shall have
a green status LED to advise owner of dirty filter, dirty coil,
or operational diagnostic messages. Unit shall have onebutton activation via membrane touch-pad. Unit control
board shall have an 18-pin low-voltage connector to allow
for easy connection to remote wired devices. Unit shall have
two serial-port connectors for easy connection to wired or
future wireless EMS (Energy Management Systems).
Unit must have the ability to easily configure ownerselectable and programmable functions:
• • Fan-cycle operation
• • Electronic temperature limiting for cooling
• • Electronic temperature limiting for heating
• • Enhanced dehumidification cooling operation
• • Temperature set-back when inactive
• • Un-rented temperature set-back
• • Load-shedding operation
• • Front-desk on-off or temperature set-back
Unit must have the ability to connect to approved remote
devices:
• Wireless or wired thermostat
• Wireless or wired door switch
• Wireless or wired room occupancy sensor
• Wireless or wired room-to-room transfer fan
• Front Desk Control
• RF wireless communications devices
Unit must be able to acquire and display operational
temperature data from up to six installed thermistors to
include:
• IAT—Indoor air temperature (black)
• ICT—Indoor coil temperature (red )
• IDT—Indoor discharge temperature (yellow)
• OCT—Outdoor coil temperature (blue) (heat pumps)
• Green—Miscellaneous temperature (ex. Outdoor ambient)
(optional)
• Orange—Miscellaneous thermistor or analog device
(optional)
Unit Chassis
Each unit must be of slide-out design shipped with room
cabinet front-installed. Unit chassis must have the ability
to be installed with 0 clearance from finished floor. An
electrical power cord must be included with chassis and
installed by the manufacturer to assure proper NEMA 6 or 7
configuration and UL-approved length. Units less than 250
volts must also have a LCDI power cord. Unit must be tested
for conformance to ASTME water infiltration specification
ASTME 331-86, which ensures no water infiltration when
tested at 8" rain per hour at 63 mph wind for 15 minutes.
Room Cabinet
The monochromatic front of the room cabinet must be able to
be field-secured to chassis to inhibit tampering. Filter must be
accessible without removing room front. Cabinet depth must
not exceed 7⅜” to minimize unit’s impact on room space.
Coils
Unit coils must have rifled copper tubing expanded into
rippled-edge louvered aluminum fins. Exterior coil must be
of a two-row bent coil design with removable shroud top
to allow easy-access for cleaning of the exterior coil.
Heat Pumps
Each unit must include a change-over thermistor that
senses an outside ambient switch-over temperature as low
as 24°F, lock-open refrigerant reversing valve during heat
pump operation, temperature-activated defrost drain,
and automatic emergency heat operation to override the
heat pump’s change-over thermostat and bring on electric
resistance heaters in the event of a sealed system failure.
Unit must not operate compressor and electric heaters
simultaneously.
Compressor
The compressor must be hermetically sealed, internally
isolated, rotary-type, and permanently mounted on rubber
isolators. No removal or adjustment of compressor holddown bolts is to be required during installation.
Evaporator/Condenser Fans
Warranty
Air Discharge
The warranty is for Full One Year on the entire unit; Full
Second through Fifth Year on the entire sealed refrigerant
system components; Limited Second through Fifth Year on
functional parts only.
Must be a sloped surface so that obstructions cannot
be placed on the unit. Discharge conditioned air can be
directed into the room at an angle of 15 or 40 degrees
from the vertical position. The discharge grille must be of
polycarbonate material to resist bending, cracking, rusting
and corrosion.
12
Direct drive with a permanent, split-capacitor, two-speed
motor. Condensate must be directed onto the back and
sides of the bent coil to aid in evaporation and removal.
www.amana-ptac.com
SS-DPTAC
SPECIFICATION SHEET
NEW INSTALLATIONS TYPICALLY REQUIRE A MINIMUM OF WS900D WALL SLEEVE AND AN OUTDOOR GRILLE.
Wall Sleeves (WS900D)
Outdoor Grilles
The wall sleeve must be industry-accepted dimensions:
14⅛” depth x 42” width x 161/16” height and constructed
of G90 HDG galvanized steel with a baked corrosioninhibiting urethane primer and baked-polyester topcoat
enamel. Sleeve must be insulated and shipped with a
weather resistant rear closure panel installed.
Outdoor grille must be architecturally extruded, louvered
aluminum (AGK01*B), one-piece polymer-blend injection
molded louver (PGK01*B) or standard stamped aluminum
(SGK**B). All other grilles must be submitted to the PTAC
manufacturer for feasibility, airflow characteristics and
compliance with UL regulations, where necessary.
THE OPTIONAL ACCESSORIES LISTED BELOW PERFORM SPECIFIC FUNCTIONS REQUIRED IN SOME INSTALLATIONS.
Condensate Drain Kit (DK900D)
Duct Kits (MDK02B, EDK02B, TDK02)
Attaches to the bottom of the wall sleeve for directionalcontrolled internal or external disposal of condensate,
defrost or rain water.
Three kits must be supplied to provide ducted, conditioned
air into a second room: a main duct kit, an extension duct
kit and a terminal duct kit.
Sub-base Kit (PTSB***E)
Hydronic Heat Kit
Necessary for UL listing requirements for 265V units (Hard
Wire Kit may be substituted for Sub-base kit). Optional
for 230/208V units. Must be pre-wired to facilitate
field-electrical connections and include a NEMA 6 or 7
configuration electrical receptacle. It must have 2 leveling
screws for sleeve support and accurate unit leveling during
installation. Locations for field installation of physical
disconnect switches, cartridge-style fuse holders and
circuit breakers must be provided. Side-skirts must be
provided with sub-bases. (PTSB000E Non-Electrical Subbase available.)
Required for heating functions instead of electric resistance
heaters. Unit must retain complete service access with the
kit installed. Proper water or steam valves must be used.
Power Vent & Damper
Must be provided to maximize ventilation air intake to up to
approximately 95 CFM. Power vent must be off and damper
door closed when unit fan is de-energized.
Condensate Removal Pump (Heat Pumps only)
Must be installed to assist in removing the condensate
developed by the heat pump operation and transfer it to
the indoor coil to dissipate into the room, adding humidity
to the room.
Circuit Breaker Kit
Must be installed in sub-base to provide overcurrent
protection for proper 230/208V amperage. Can also be
used as a physical disconnect where local codes permit for
230/208 voltage.
Hard Wire Kit
Must be installed either in the unit or the sub-base and
must match the electrical requirements of the chassis.
Must be used to permanently wire chassis for hard wire
purposes. (For 265V units, Hard Wire Kit may be substituted
with Sub-base Kit.)
Security Key Locks (KL03B)
Charcoal Filter Kit -- Optional (CFK10B)
Fuse Holder (included in 265V chassis)
Must be installed to prevent tampering of the unit controls.
Unit room cabinet must also be secured to the chassis with
field supplied screws. UL-approved for institutional use
only.
Disconnect Switch
Power disconnect switch must be installed in sub-base
for use as a physical disconnect, where required by local
codes.
SS-DPTAC
Amana® brand Activated Charcoal filters absorb odors
caused by cigarette, pipe or cigar smoke and airborne odors
caused by mold, mildew, etc. These replacement filters are
polyester fibers coated with activated charcoal. Each filter
is individually wrapped to assure maximum absorption and
durability when installed. (10 filters per kit.)
Thermostats
A manufacturer-approved manual, auto changeover or
programmable traditional-wired thermostat must be
installed to provide full remote operation of the chassis. A
Remote Escutcheon Kit must be used to indicate remote
operation.
www.amana-ptac.com
13
Specification Sheet
INSTALLATION: UNIT WITH ACCESSORY WALL SLEEVE AND SUB-BASE ACCESSORY
42"
40"
TOP VIEW
6 - 1 / 8"
9 - 9 / 16"
24 - 5 / 16"
1"
Location of external drain holes
on bottom flange of Wall Sleeve
Air
Flow
Air
Flow
Air
Flow
Control
Door
Air Discharge Grille
3
AIR DISCHARGE GRILLE IS
REVERSIBLE TO PROVIDE EITHER
15° OR 40° DISCHARGE ANGLE
1"
3" Clearance
to side walls
"
7/8"
STAMPED GRILLE
21-1/2"
RIGHT VIEW
1-3/8"
ARCH GRILLE
14-1/8"
WALL SLEEVE
7-3/8"
15°
40°
16-1/16"
HINGED
CONTROL
DOOR
OPTIONAL
SUBBASE
4"
13/16"
1 -3 /8"
11-3/8"
13/16"
1/2" O.D.
COPPER
DRAIN TUBE
42"
2-3/4"
FRONT VIEW
LEFT
58” LCDI CORD
SET 230V/208V
UNIT*
R I GHT
16-1/16"
2-5/8"
3-1/4"
MIN
2"
MAX
1" AND 3/4" CONCENTRIC KNOCKOUTS BACK
& BOTTOM OF SUBBASE (ELECTRICAL ONLY)
14
www.amana-ptac.com
58" CORD
SET 230V/208V UNIT*
18" CORD
SET 265V UNIT*
SS-DPTAC
SPECIFICATION SHEET
FRAMING FOR ACCESSORY WALL SLEEVE (WS900D)
JACK STUDS
Alternative
Fastening Method
(Field Supplied)
Wood Screw
Toggle Bolt
Expansion
Anchor Bolt
Mounting
Holes
(Drilled by
Installer)
HEADER - 4" x 4" OR
DOUBLE 2"x 4" ON EDGE
MAIN STUD
16 1/4"
MIN
42
1/4
"
JACK STUD
Plastic
Anchor
Screws
CRIPPLE
ADJUST FRAMING TO
SECURE THIS DIMENSION
Wall Sleeve must extend
a minimum of ¼” beyond
outside wall to allow for
proper caulking.
FINISHED FLOOR
SUB-FLOOR
FASTENING WALL SLEEVE
When installed in an opening, the Wall Sleeve must be
horizontally level (side-to-side) and pitched ¼ bubble to the
outside. (NOTE: To ensure unit’s maximum efficiency, DO
NOT over- or under-pitch.)
Wall Sleeve Opening Height
should be squared with
Wall Sleeve Opening Width
H = 16¼"
W = 42¼"
INSTALLATION NOTES
1. If Sub-base (PTSB***E) is installed, allow minimum 3¼” height clearance and maximum 5” height clearance between wall
sleeve and floor; allow minimum 2¾” protrusion from a finished wall. See Note 4 if using hydronic units.
2. Drain Kit (DK900D) shipped separately. Can be mounted either right side, left side, or bottom of sleeve. If mounted to
bottom of sleeve, allow 2” height clearance from floor to bottom of sleeve.
3. For UL approval, 265V units must use Amana® brand Sub-base (PTSB***E) or Amana® brand Hard-Wire Kit (PTPWHWK4).
Overcurrent protection on 265V units must be by cartridge-style time-delay fuses, which are included and factoryinstalled on the Amana® brand 265V chassis.
4. If Hydronic Kit (HWK03B or HVK03B) is installed, Wall Sleeve must extend exactly 3" into the room from the finished
interior wall. If using the Amana® brand Sub-base (PTSB***E), only the minimum 3¼” height clearance between wall
sleeve and floor is permissible. Unit must also be operated with a remote-mounted thermostat.
5. If Duct Kit (MDK02B) is installed, allow a minimum of 2⅜” into the room from the finished interior wall.
SS-DPTAC
www.amana-ptac.com
15
Specification Sheet
NOMENCLATURE
P
T
C
0
9
3
A
3
5
A
M
Major Design
Series
Package
Terminal
Heater Sizes
Model Type
00 = 0.0 kW 35 = 3.5 kW (230/208v)
15 = 1.5 kW
3.7 kW (265v)
25 = 2.5 kW 50 = 5.0 kW
C = Cooler
H = Heat Pump
Nominal Cooling Capacity
Special Feature Code
07 = 7,000 BTU/h
09 = 9,000 BTU/h
A
B
C
D
J
K
L
P
Y
12 = 12,000 BTU/h
15 = 15,000 BTU/h
Electrical
2
3
4
5
115v, 60 Hz
230/208v, 60 Hz, 1 Ph
265v, 60 Hz, 1 PH
240/220v, 50 Hz, 1 Ph
Standard Model
Power Vent
Seacoast Model
Condensate Disposal Pump
Power Door
Condensate Pump w/ Power Vent
Condensate Pump w/ Power Door
Hydronic w/Manual Door
230/208-volt Fuse Holder
Engineering Design Series
M
DigiSmart Unit
(230/208 or 265v only)
N
Premium DigiSmart
w/ LED (230/208 or 265v only)
Amana® is a trademark of Maytag Corporation and used under license to Goodman
Company, L.P. All rights reserved. Our continuing commitment to quality products may
mean a change in specifications without notice.
Copyright © 2007 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
16
www.amana-ptac.com
SS-DPTAC