very important very important caution

very important very important caution
VERY IMPORTANT
Do not install and use your portable air conditioner
unit before carefully reading this instruction guide.
Please retain this manual brochure for product
MODEL: DXAC12000
warranty and future reference
INSTRUCTION FOR USE
CAUTION
1." DO NOT BLOCK VENTILATION "! Please make sure the inlet and
outlet ventilation is not blocked at all times.
2. Operate this unit on a horizontal surface to avoid water leakage.
3. Do not operate this unit in an explosive or corrosive atmosphere.
4. Operate this unit in an ambient of 32 degree centigrade or less.
5. Clean air filter periodically to enjoy the most efficient cooling.
6. When the unit is shut off, please wait at least 3 minutes before
restarting; this is to prevent the compressor from being damaged.
7. This unit needs at least 4.5 Amps of electricity to have its
compressor operational. To avoid the household electricity blacking
out, please do not use any extension cord for this unit.
8. This unit is for indoor cooling only.
9. Make sure the adjustable air vent is open, and also the exhaust pipe and
drain pipe are removed and extended to the closest window before using.
10.When the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid hazard.
PORTABLE AIR CONDITIONER
11.The batteries must be removed from the appliance before it is
scrapped and disposed of safely.
08/50753/0
1
CONGRATULATIONS ON YOUR
SELECTION OF A QUALITY
PORTABLE AIR CONDITIONER
UNPACKING INSTRUCTIONS
1. Place the unit in the correct upright position before unpacking.
PORTABLE AIR CONDITIONER
2. Cut the two packing straps.
Your Air Conditioner has been designed and manufactured to the
3. Slide the carton in an upwards motion and it will release from the base.
highest standards of modern engineering.
4. Grip the carry handles located on either side of the unit and carefully lift until it slides
Its many features not only include remote control operation that lets
out of the foam base.
you control all functions with ease and convenience.
- Moves easily from room to room on easy glide castors
CONTENTS
- No installation required-just plug into any household
1 / Air control unit
power outlet
2 / 1-remote control unit
- Refrigerated air system design cools instantly whenever
you want it
- Dehumidified filtered air cycle for improved breathing
conditions due to powerful dehumidification
process
-If remote control function is not required, your one touch
electronic pad provides easy to identify manual operation
-24 hour programmable timer that can be used with either the
air conditioning or dehumidification setting
-Unique sleep control function
-230-240 Volt 50Hz operation
-1.6 meter cord with plug
2
3
TACK SWITCH & DESCRIPTION OF FUNCTION
NAME OF THE PARTS
1. Tack switch
2. Display screen
3. Adjustable air vent
4. Joint tube
5. Exhaust tube
1. POWER KEY
Press to turn unit "ON” or "OFF".
2. FUNCTION
Press this key to select either refrigerated air or dehumidification cycle.
3. TEMPERATURE
6. Cool inlet
7. Cool Air filter
REGULATION
8. Hot inlet
KEY (UP)
4. TEMPERATURE
9. Drain pipe
REGULATION
10. Hot air filter
This key raises the preset temperature by 1℃ each time it is
pressed to a maximum of 30℃
This key lowers the preset temperature by 1℃ each time it is
pressed to a minimum of 15℃ .
KEY (DOWN)
※ In normal conditions, the temperature data which appears on the panel is the ambient
temperature, not the temperature which is set by the user. When the user has adjusted
and set the temperature as required, the data on the panel will return to the ambient
temperature 5 seconds later.
The ambient temperature will descend or change according to the temperature which is
set by the user, but the temperature descendant time and speed will depend on the
environment and space where the model is.
For example, if the ambient temperature is too hot or the room is too large, the speed for
4
5
the temperature descent will be slow, and the cooling efficiency will be poor as well.
5. L.E.D. DISPLAY
automatically.
3. Press the "POWER" key before time out, the setting time will
Indicates the temperature or the time setting. After any time set
the display will return to the present temperature automatically.
be canceled and the unit will turn on.
TIMER-OFF: The timer-off is used to turn off the unit automatically after the setting time is over.
Error Display
E1: Indicates open circuit or short circuit in room temperature sensor.
1. Press the "TIMER" key at stand-by status to set the time
E2: Indicates open circuit or short circuit in pipe temperature sensor.
desired.
E7: Indicates the water is full inside.
2. Once the set hour has come to an end, the unit will turn off
Please contact an authorized service centre if any of the above error messages are shown.
automatically.
6. SPEED
3. Press the "POWER" key before the time out, the setting
Press to select either LOW, MEDIUM, HIGH or AUTO fan
time will be canceled and the unit will turn off.
speed.
If "AUTO" is selected, the unit operates at maximum cooling
capacity when the room temperature is more than 2℃ below the
setting temperature.
8.SLEEP CONTROL
FUNCTION
When setting the "sleep comfort" mode please ensure that you
then set the number of hours required and press the timer
button till those hours are indicated on the L.E.D display. After
When the room temperature is less than 2℃ below the setting
setting the hours the L.E.D. display will automatically return to
temperature,
the current pre-set temperature. To increase this setting "up"
the unit operates at middle cooling capacity.
When the room temperature is equal the setting temperature, the
press the button indicated and for each press, the temperature
unit operates at minimum capacity.
will be increased by 1℃. Likewise to set for a lower temperature
If "HIGH" is selected, the unit operates at maximum cooling
press the button indicated and for each press the temperature
capacity no matter what the setting temperature is. "MEDIUM"
will be decreased by 1℃.
OR “LOW" operate as normal.
During the course of this cycle, to ensure maximum sleep
7. PROGRAMMABLE Programmable timer ON/OFF key.
TIMER
TIMER-ON: The timer-on is used to turn on the unit automatically after the set time is over.
1. Press the "TIMER" key at stand-by status to set the time
comfort. , the micro-processor memory will raise the pre-set
temperature 0.5℃ each half hour to a maximum of 2℃ over two
hours and then maintain that temperature for the remainder of
the time set.
desired.
2. Once the set hour has come to an end, the unit will turn on
6
7
The portable air conditioner is fitted with a 3 minute compressor
REMOTE CONTROL FUNCTION
delay protection circuit which simply means that the compressor
requires 3 minutes to start. From either being swiched on, or
when changing from “dehumidify” to any air conditioning cycle
chosen.
9.
ALARM
Indicates condensed water drainage required. However, if
the unit fails to get rid of the condensation in extremely humid
weather, the “water full” alarm on the control panel will light up and
the unit wil cease operating. To resume operation, simply remove
the rubber cap of the drain hose to drain out the excessive
condensation inside.
8
1. POWER
Stop/Start switch
2. FUNC
Function “MODE” selector
3. TIMER
Hourly programming
4. AUTO
Automatic fan speed
5. HI
High fan speed
6. MID
Medium fan speed
7. LOW
Low fan speed
8. SLEEP
Night operation selector
9. TEMP.
Temperature selector
9
INSTALLATION
MAINTENANCE
Install the portable air conditioner in a flat and spacious location where
PLEASE DISCONNECT THE POWER CORD BEFORE CLEANING.
the air inlets and outlets will not be blocked. A minimum clearance of
40cm from a wall or other obstacles should be kept (as below picture).
The appliance should not be used in the laundry.
AIR FILTER
The air filter located on the left hand side of the unit can be
removed, simply by pulling the frame in an outward motion.
CONDENSER/EVAPORATOR
Use a vacuum cleaner with a brush attachment.
CABINET
Wipe with a damp cloth and polish with a soft cloth.
NOTICE
This unit can evaporate the condensation and flow out through
the exhaust hose automatically.
When the unit is running, it does not need to install the drain hose.
Please make sure that the rubber cap is locked on the drain hose,
when the unit is running.
10
11
To remove the air filter, please follows the arrow direction and push the
filter lightly, and then take out the filter for cleaning.
(3) Do not place the machine in a sunlit corner otherwise the colors
soon fade out of the machine.
HELPFUL HINTS
The unit is fitted with a special thermal cut off device.
Please ensure the unit is not placed against objects which will
POWER SUPPLY
obstruct air intake e.g. furniture or curtains as this will affect its
performance dramatically.
(1) Confirm the correct power.
(2) Insert the plug into the outlet firmly.
Do not place the unit in direct sunlight, as this may cause the unit
to overheat and turn off.
In case of dangerous leaks, prevent the AC cord from
scarring.
(3) Don’t pull power wire by force because it will cause damage
to power wire.
PLACEMENT FOR USE
(1) Because the machine expels hot air, please do not operate in a
narrow place.
(2) In case of dangerous leaks, do not operate the machine in a humid
place.
12
13
EXHAUST TUBE INSTALLATION
SPECIFICATION
1.
When not in use, fold up the
Model No.
DXAC12000
slightly & pull away from the unit,
exhaust, and hook up the buttons,
Power Source
230-240V~ 50Hz AC
the following picture indicates the
fixing the exhaust on the unit.
Power Consumption
1400W
Max Power
1480W
Cooling Capacity
3400W
Air Flow
420 M3/H
Moisture Removed
50 L/DAY
Refrigerant
R410A
For room size
10 – 25 m2
Dimensions (mm)
476Wx358Dx840H
Net Weight
29.5KG
To remove the exhaust pipe, press
2.
removal of the exhaust pipe.
14
1
Recycling
For electrical products sold within the European Community. At the end of
the electrical products useful life it should not be disposed of with
household waste. Please recycle where facilities exist. Check with your
local Authority or retailer for recycling advice in your country.
After Sales Service
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free of
charge (subject to availability), within the guarantee period provided it has
been operated in accordance with these instructions.
Your rights under this guarantee are additional to your statutory rights,
which in turn are not affected by this guarantee.
Should you require after sales information or assistance with this product,
please contact our helpdesk on 0845 600 5111 (UK)
Please retain your receipt as proof of purchase.
Dimplex UK Ltd.
Web: dimplex.co.uk
Millbrook House
Grange Drive
Helpdesk: 0845 600 5111
Hedge End
Southampton
Hampshire. SO30 2DF
2
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement