SmartOnline 200-240V 10kVA 9kW Double-Conversion

Add to my manuals
6 Pages

advertisement

SmartOnline 200-240V 10kVA 9kW Double-Conversion | Manualzz
SmartOnline 200-240V 10kVA 9kW
Double-Conversion UPS, 6U, Extended Run,
Network Card Slot, USB, DB9, Switch, Hardwire
Highlights
10kVA/10,000VA/9000W on-line
double-conversion UPS; 0.9
power factor
200/208/220/230/240V 50/60Hz
MODEL NUMBER: SU10KRT3UHV
output; Economy mode option
6U Rack / Tower compatible;
Hot-swappable power and
battery modules
USB, RS232 & EPO ports; slot
for optional Network
Management Cards
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (3 wire); Hardwire
output (3 wire)
Description
Package Includes
Tripp Lite SU10KRT3UHV 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete
power protection for critical network applications. This system delivers online, double-conversion UPS protection
with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents
unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with
manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to
connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this
UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged
industrial locations.
SU10000RT3UPM 3U UPS
power module
BP240V10RT3U external battery
pack
SUPDMB710HW Detachable
PDU with manual bypass switch
Four post compatible rack rail kit
(2 sets)
Tower stands for upright tower
Features
Tripp Lite SU10KRT3UHV 10kVA/10,000VA/9000 watt on-line, double-conversion UPS system in 6U total
configuration
rack/tower configuration (3U UPS power module and 3U external battery pack)
USB, DB9 and EPO cabling
Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no
User manual
interruption in output power to connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input (3 wire) and hardwire output (3 wire) connections
Supports North American (L1,L2,G) 208/240v hardwire input / output, plus International 230/220/240v (L,N,PE) hardwire input / output
Optional SU6000XFMR2U transformer offers 120v output in North American 208/240V (L1,L2,G) input configurations
Maximum installed rack depth of only 32.5 in. / 82.6cm
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection
from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as
300V
1/6
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH
external battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Intelligent battery management system with temperature-compensated charging extends battery life
Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and
require replacement
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from
www.tripplite.com/poweralert
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD
Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB
interface module)
Supports Emergency Power Off (EPO) via built-in interface
Included rail kit supports 6U 19 inch rackmount installation in 4 post racks
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks
Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS
settings for charge level, nominal voltage selection, frequency conversion and other operational parameters
LED / LCD display panel rotates for viewing in rackmount or tower configurations
Network-grade AC surge and noise suppression
Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration
overload conditions
Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
External battery packs are field replaceable and hot swappable
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
10000
Output kVA Capacity (kVA)
10
Output Watt Capacity (Watts)
9000
Output kW Capacity (kW)
9.0
Output Capacity Details
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30
seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;
Double conversion mode is automatically restored as load levels are reduced to 95% or less
Power Factor
0.9
Crest Factor
3:1
Nominal Output Voltage(s)
Supported
200V; 208V; 220V; 230V; 240V
Nominal Voltage Details
Voltage selection via front panel LCD interface
Frequency Compatibility
50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
2/6
Frequency Compatibility Details
Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to
50Hz or 50Hz to 60Hz (no de-rating); Output frequency regulation +/- 0.05Hz (free running)
Output Voltage Regulation (Line
Mode)
+/- 2%
Output Voltage Regulation
(Economy Line Mode)
+/- 10%
Output Voltage Regulation (Battery
Mode)
+/- 2%
Output Receptacles
Hardwire
Output Receptacle Details
Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output;
*For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
Output AC Waveform (AC Mode)
Pure Sine wave
Output AC Waveform (Battery Mode)
Pure Sine wave
INPUT
Rated input current (Maximum Load)
56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)
Nominal Input Voltage(s) Supported
200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type
Hardwire
UPS Input Connection Description
Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
Recommended Electrical Service
60A
Input Phase
Single-Phase
BATTERY
Full Load Runtime (min.)
4.3 min. (9000w)
Half Load Runtime (min.)
12.5 min. (4500w)
Expandable Battery Runtime
Supports extended runtime with optional external battery packs
External Battery Pack Compatibility
BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH ; BP240V1037C-1PH; BP240V1407C-1PH
DC System Voltage (VDC)
240
Battery Recharge Rate (Included
Batteries)
Less than 6 hours from 10% to 90% (typical, full load discharge)
Battery Replacement Description
Hot-swappable, user replaceable external battery packs
Expandable Runtime
Yes
VOLTAGE REGULATION
Voltage Regulation Description
2% output voltage regulation in standard online, double-conversion mode
Overvoltage Correction
Corrects overvoltages up to 300V
Undervoltage Correction
Corrects undervoltages as low as 100V
USER INTERFACE, ALERTS & CONTROLS
3/6
Front Panel LCD Display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN,
ITALIAN, SPANISH and PORTUGUESE (see manual)
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module
replacement
Alarm Cancel Operation
Alarm cancel switch
Audible Alarm
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options
SURGE / NOISE SUPPRESSION
UPS AC Suppression Response
Time
Instantaneous
EMI / RFI AC Noise Suppression
Yes
PHYSICAL
Included Mounting Accessory
Description
2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included
Installation Form Factors Supported
with Optional Accessories
2 post rackmount(2POSTRMKITHD )
Optional Mounting Accessory Notes
2 sets of 2POSTRMKITHD required for 2 post rackmount installation of all included components
Primary Form Factor
Rackmount
UPS Power Module Dimensions
(hwd, in.)
5.14 x 17.5 x 25.82
UPS Power Module Dimensions
(hwd, cm)
13.06 x 44.45 x 65.58
Rack Height (U Spaces)
6
Maximum Device Depth (in.)
32.5
Minimum Required Rack Depth
(inches)
37.5
Maximum Device Depth (cm)
82.55
Minimum Required Rack Depth (cm)
95.25
UPS Power Module Weight (lbs.)
43
UPS Power Module Weight (kg)
19.50
UPS Dimensions Details
Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710HW PDU with bypass; MAXIMUM
DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
Included Battery Pack Dimensions
(hwd / in.)
5.25 x 17.5 x 25
Included Battery Pack Weight (lbs.)
158.7
Included Battery Pack Weight (kg)
71.99
UPS Shipping Dimensions (hwd / in.)
38.25 x 31.5 x 23
4/6
UPS Shipping Dimensions (hwd /
cm)
97.16 x 80.01 x 58.42
Shipping Weight (lbs.)
327.6
Shipping Weight (kg)
148.7
Cooling Method
Fan
UPS Housing Material
Steel
Maximum Device Depth (mm)
826
Minimum Required Rack Depth (mm)
952
Primary UPS Height (mm)
131
Primary UPS Width (mm)
444
Primary UPS Depth (mm)
656
Shipping Height (mm)
972
Shipping Width (mm)
800
Shipping Depth (mm)
584
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
3415
AC Economy Mode BTU / Hr. (Full
Load)
1280
Battery Mode BTU / Hr. (Full Load)
4593
AC Mode Efficiency Rating (100%
Load)
91%
AC Economy Mode Efficiency Rating
(100% Load)
96%
Operating Elevation (ft.)
0-3000m (0 to 10,000 ft.)
Audible Noise
60 dBA at front side 1 meter
Operating Elevation (m)
0-3000 m
COMMUNICATIONS
Communications Interface
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network Management Cards
SNMPWEBCARD; TLNETCARD; WEBCARDLX ; MODBUSCARD; RELAYIOCARD
Network Monitoring Port Description
Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI
installation requires removal of panel containing USB ports
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
http://www.tripplite.com/poweralert
5/6
Communications Cable
USB, DB9 serial and EPO cables included
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time
No transfer time (0 ms.) in online, double-conversion mode
Transfer Time (Economy Mode)
8 ms. typical power failure response in optional economy mode
Low Voltage Transfer to Battery
Power (Setpoint)
100V
High Voltage Transfer to Battery
Power (Setpoint)
300V
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
Cold-start operation supported
Economy Mode Operation
Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of
+/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1
millisecond transfer time between modes.
High Availability UPS Features
Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
Green Energy-Saving Features
High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A
(EMI)
UPS Certification Details
IEC 61000-4-5 1995 B Surge Immunity
WARRANTY
Product Warranty Period (Worldwide)
2-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime Insurance
© 2017 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:
https://www.tripplite.com/products/product-certification-agencies
6/6

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement