AUTOMATIC DRYER
INSTALLATION INSTRUCTIONS
The installation, including a proper exhaust system, is the responsibility of the owner.
LEAVE THESE INSTRUCTIONS WITH THE OWNER
Printed in U.S.A.
6 3716990
Read this before you start...
Tools needed for installation
• Teflon tape or pipe joint compound (gas only)
• Cutting knife
• Pipe wrench (gas only)
• Nut drivers
• Level
• Screw driver (standard)
• Duct tape
• Crescent wrench
ITEMS PROVIDED
®®o gQ
® %d\@ @
Electric Dryer
Only
Proper installation is the responsibility of the owner.
HOWEVER, SERVICE CALLS PERFORMED AS A RESULT OF POOR SET-UP, ADJUSTMENT
CONNECTION ARE THE RESPONSIBILITY OF THE INSTALLER.
Gas Dryer
Only
AND
Make sure you have everything necessary for proper installation.
1. GROUNDED ELECTRICAL OUTLET is required.
See Electric Requirements.
2. POWER CORD for electric dryers (except Canada).
3. GAS LINES (if a gas dryer) must meet National and Local Codes.
4. EXHAUST SYSTEM - must be rigid metal or flexible stiff walled metal exhaust ducting.
See Exhaust Requirements.
43 1/4" minimum
36.1/4"
_Imlnlmum
1 1/2"
IMPORTANT TO INSTALLER
PLEASE READ THE FOLLOWING INSTRUCTIONS
CAREFULLY BEFORE STARTING TO INSTALL
THE DRYER.
THESE INSTRUCTIONS SHOULD
BE RETAINED FOR FUTURE REFERENCE.
REMOVE THE DOOR FROM ALL DISCARDED
APPLIANCES SUCH AS DRYERS TO AVOID THE
DANGER OF A CHILD SUFFOCATING.
LOCATION CONSIDERATIONS
The dryer should be located to permit adequate room in front for loading the dryer, and sufficient room behind the dryer for the exhaust system.
This dryer is factory-ready for rear exhaust.
To exhaust out the bottom or left side, use the accessory exhaust kit (see Accessories).
included with the kit.
Instructions are
It is important to make sure the room has adequate make-up air. The area where the dryer is located must not obstruct the flow of combustion or ventilating air.
On gas dryers, adequate clearance as noted on the data plate must be maintained to insure adequate air for combustion and proper operation of the dryer.
THE DRYER MUST NOT BE INSTALLED OR
STORED IN AN AREA WHERE IT WILL BE
EXPOSED TO WATER AND/OR WEATHER.
THE
DRYER AREA IS TO BE KEPT CLEAR AND FREE
FROM COMBUSTIBLE MATERIALS, GASOLINE
AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.
A DRYER PRODUCES COMBUSTIBLE
LINT.
THE AREAAROUND THE DRYER SHOULD
BE KEPT FREE OF LINT.
ALCOVE OR CLOSET
INSTALLATION
An appliance installed in a closet shall have no other fuelburning appliance installed in the same closet.
_I,WARNING WARNING-
The dryer must be exhausted to the outside to reduce the risk of fire when
Each opening area in the door must installed in an alcove or closet• have a minimum of 36 square inches.
These openings must not be obstructed.
(Louvered door with eq i air opening is acceptable.)
CLOSET DOOR
[7,, 2
0"
FRONT VIEW
Minimum installation clearances.
clearance is recommended.
If possible, more
MOBILE HOME INSTALLATION
The installation of the dryer in mobile homes must conform to the Manufactured Home Construction and
Safety Standard Title 24 CFR, Part 32-80 {formerly the Federal standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280), 1975} for the
United States,) or CSA Standards Z240 (for Canada).
When installing a dryer in a mobile home, provisions for anchoring the dryer to the floor must be made.
An anchor bracket kit is available with instructions
(see Accessories).
Locate in an area that has adequate make up air. A minimum of 25 square inches of unobstructed opening is required.
All mobile home installations must be exhausted to the outside with the exhaust duct termination securely fastened to the mobile home structure, using materials that will not support combustion.
The exhaust duct may not terminate beneath the mobile home.
See the section on exhausting for more information.
EXHAUSTING
Exhausting the dryer to the outside will prevent large amounts of lint and moisture from being blown into the room.
In the United States:
• all gas dryers must be exhausted to the outside.
• electric dryers located in a confined area such as a bedroom, bathroom, or closet must be exhausted to the outside.
• electric dryers not located in a confined area may be exhausted to the inside (see nonexhausted installations).
In Canada:
• all gas and electric dryers must be exhaust- ed to the outside.
Outside the U.S. and Canada:
• refer to local codes.
_,WARNING WARNINGplastic or nonmetal flexible duct presents a potential fire hazard•
NEVER USE PLASTIC OR NON-
METAL FLEXIBLE DUCT.
If your existing ductwork is plastic, nonmetal or combustible, replace it with metal.
Use only metal exhaust duct that will not support combustion to insure the containment of exhaust air, heat and lint.
Plastic flexible duct can kink, sag, be punctured, reduce air flow, extend drying times and affect dryer operation.
USE A MINIMUM OF 4-INCH DIAMETER RIGID
ALUMINUM OR RIGID GALVANIZED STEEL
DUCT.
Do not use smaller duct.
Ducts larger than
4 inches in diameter can result in increased lint accumulation.
Lint accumulation should be cleaned regularly.
If flexible metal duct must be used, use the type with a stiff sheet metal wall.
Do not use flexible duct with a thin foil wall.
Serious blockage can result if flexible metal duct is bent too sharp.
Never install any type of flexible duct in walls, ceilings or other concealed spaces.
Number of
90° Turns
Exhaust Hood Type
0
3
4
1
2
Maximum length of 4-inch diameter rigid metal duct
65 ft.
54 ft.
44 ft.
36 ft.
28 ft.
59 ft.
48 ft.
38 ft.
30 ft.
22 ft.
0
1
2
3
4
Maximum length of 4-inch diameter flexible stiff walled metal duct
36 ft.
32 ft.
28 ft.
25 ft.
23 ft.
28 ft.
24 ft.
20 ft.
17ft.
15ft.
Keep exhaust duct as straight and short as possible.
Exhaust systems longer than recommended can extend drying times, affect machine operation and may collect lint.
Secure joints with duct tape.
Do not use screws.
DO NOT EXHAUST DRYER INTO ANY WALL,
CEILING, CRAWL SPACE OR A CONCEALED
SPACE OF A BUILDING, GAS VENT, ANY
OTHER COMMON DUCT OR CHIMNEY.
THIS
COULD CREATE A FIRE HAZARD FROM LINT
EXPELLED BY THE DRYER.
The exhaust duct should end with an exhaust hood with a swing out damper to prevent backdrafts and entry of wildlife.
Never use an exhaust hood with a magnetic damper.
The hood should have at least
12 inches of clearance between the bottom of the hood and the ground or other obstruction.
The hood opening should point down.
Never install a screen over the exhaust outlet.
When possible, do not exhaust the dryer directly into a window well in order to avoid lint build-up.
Do not exhaust under a house or porch.
If exhaust ductwork must run through an unheated area, the duct should be insulated and slope slightly down towards the exhaust hood to reduce condensation and lint build-up.
If an existing exhaust system is to be used with your new dryer, you must be sure:
• The exhaust system meets all local, state and national codes.
• That plastic flexible duct is not used.
• To completely inspect and clean all lint accumulation from the interior of the duct.
• The duct is not kinked or crushed.
• The exhaust hood damper opens and closes freely.
The static pressure in any exhaust system must not exceed 0.92 inches of water column, or be less than 0. This can be measured with the dryer running with a manometer at the point where the exhaust duct connects to the dryer.
A no heat setting should be used.
The dryer tumbler should be empty and the lint filter clean.
Inspect and clean the interior or the exhaust system at least once a year.
Disconnect electrical service prior to cleaning.
Check the gas line on gas dryers anytime the dryer is moved.
Frequently check to be sure the exhaust hood damper opens and closes freely.
NONEXHAUSTED INSTALLATIONS
If the electric dryer is not exhausted to the outside, the exhaust must not terminate directly behind the dryer.
Use a rectangular vent kit along with a dacron mesh lint bag (see Accessories).
Maintain a
6" clearance between the back of the control panel and the wall.
Although the lint screen and lint bag will retain most of the lint, a certain amount will be expelled into the laundry area.
WARNING: IF THE DRYER IS NOT EXHAUSTED
TO THE OUTSIDE, SOME FINE LINT WILL BE
EXPELLED INTO THE LAUNDRY AREA.
AN
ACCUMULATION OF DUST OR LINT IN ANY
AREA OF THE HOME CREATES A FIRE
HAZARD.
ANY LINT ACCUMULATIONS
BE CLEANED FREQUENTLY.
MUST
GAS REQUIREMENTS
Use only Natural or LP (liquid propane) gases.
THE INSTALLATION MUST CONFORM WITH
LOCAL CODES, OR IN THE ABSENCE OF
LOCAL CODES, WITH THE NATIONAL FUEL
GAS CODE ANSI/Z223.1, LATEST REVISION
(FOR THE UNITED STATES), OR WITH THE
CAN/CGA-B149 INSTALLATION CODES (FOR
CANADA).
Gas dryers are equipped with a burner orifice for operation on NATURAL gas.
If the dryer is to be operated on LP (liquid propane) gas, it must be converted for safe and proper performance and must be converted by a qualified service technician.
Conversion kits from NATURAL to LP, or LP to NATURAL are available through your local
Maytag dealer (see Accessories).
If other conversions are required, check with the local gas utility for specific information concerning conversion requirements.
A 1/2" gas supply line is recommended and must be reduced to connect to the 3/8" gas line on the dryer.
The National Fuel Gas Code requires that an accessible, approved manual gas shut off valve be installed within 6 feet of the dryer.
Additionally, a 1/8" N.RT. (National Pipe Thread) plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer.
The dryer must be disconnected from the gas supply piping system during any pressure testing of the system.
DO NOT re-use old flexible metal gas line.
Flexible gas line must be design certified by American Gas
Association (CGA in Canada).
NOTE: Any pipe joint compound used must be resistant to the action of any liquefied petroleum gas.
NOTE: As a courtesy, most local gas utilities will inspect a gas appliance installation.
GAS IGNITION -
This dryer uses an automatic ignition system to ignite the burner.
There is no constant burning pilot.
ELECTRICAL REQUIREM ENTS
NOTE: Wiring diagram is located inside the control console.
Export models (not U.S. or Canada): See
Additional Instructions for Export Models on the other side of this sheet.
_-WARNING WARNING - To prevent unnecessary risk of fire, electrical shock or personal injury, all wiring and grounding must be done in accordance with local codes, or in the absence of local codes, with the National Electrical Code,
ANSI/NFPA (for the United States) or the
Canadian Electrical Code CSA C22.1
(for
Canada).
GROUNDING
This dryer must be grounded.
In the event of malfunction or breakdown, the ground will reduce the risk of electrical shock by providing a path of least resistance for electrical current.
GAS MODELS
This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
-_WARNING WARNING - Improper connection of the equipment grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded.
If a separate ground is required by local codes, a grounding kit (Part No. 12001875) is available.
It contains ground wire, clamp, ground screw and washer.
Connect ground wire to back of unit with the cabinet ground screw and washer.
Secure other end of ground wire to a suitable external ground connection.
The wire may be secured with the clamp to a grounded COLD metal water pipe.
NEVER CONNECT GROUND WIRE TO PLASTIC
PLUMBING LINES, GAS LINES OR HOT WATER
PIPES.
Ground
Screw
ELECTRIC MODELS
U.S. electric models are shipped with a ground strap connected from the neutral terminal block post to the frame of the dryer.
If local codes prohibit the use of the ground strap, the dryer must be grounded in accordance with local codes.
If a power cord is not used and the electric dryer is to be permanently wired, the dryer must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal.
ELECTRICAL CONNECTIONS
BEFORE OPERATING OR TESTING, follow all grounding instructions in Grounding Section.
An individual branch (or separate) circuit serving only this appliance is recommended.
AN EXTENSION CORD.
DO NOT USE
GAS MODELS - U.S.
and Canada
A 120 volt, 60 Hz AC, approved electrical service, with a 15 ampere fuse or circuit breaker is required.
ELECTRIC MODELS U.S.
Only
Most U.S. dryers, as manufactured, require a
120/240 volt, 60 Hz AC approved electrical service.
Some require 120/208 volt, 60 Hz approved electrical service.
The electric service requirements can be found on the data label located on the front behind the door.
A 30 ampere fuse or circuit breaker on both sides of the line is required.
A 120/240 volt U.S. electric dryer must be converted if it is to operate on a 120/208 volt electrical system.
A heating element conversion kit is available (see Accessories).
If a power cord is used, the cord should be plugged into a 30 ampere receptacle.
The power cord is NOT provided with U.S. electric model dryers.
IMPORTANT: When permitted by local codes, the dryer electrical supply may be connected by means of a new power supply cord kit, marked for use with clothes dryer, that is U.L. listed, rated at 120/240 volts minimum, 30 amperes with three No. 10 copper wire conductors terminated with closed loop terminals, open-end spade lugs with turned up ends or with tinned leads.
Do not reuse a power supply cord from an old dryer.
The power cord electric supply wiring must be retained at the dryer cabinet with a suitable UL listed strain relief.
If the dryer is to be installed in a mobile home or an area where local codes do not permit grounding through neutral, only a 4 conductor power cord, rated and terminated as above, may be used.
ELECTRIC MODELS - Canada Only
A 120/240 volt, 60 Hz AC approved electrical service fused through a 30 ampere fuse or circuit breaker on both sides of the line is required.
All Canadian models are shipped with the power cord attached.
The power cord should be plugged into a 30 ampere receptacle.
NOTE: It is not permissible to convert a dryer in
Canada to 208 volts.
Do not modify the plug provided with the appliance if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
REPLACEMENT
ACCESSORIES
PARTS AND
If your dryer requires replacement parts or accessories, contact the dealer from whom you purchased your dryer or Maytag Customer
Service, Box 2370, Cleveland, Tennessee
37320-2370, phone 423-472-3333, for information on the nearest authorized Maytag
Parts Distributor.
INS TALLA TION
Parts and literature are packaged inside of dryer drum.
To Install...
• Move dryer to an appropriate location for installation.
Consider installing the dryer before the washer in side-by-side installations, to allow access to gas, electrical and exhaust connections.
Lay two of the carton corner posts on the floor.
Carefully tip the dryer forward on its front so it will lay across both corner posts.
[-_WARNING I
• Improper connection of the equipment-grc in doubt as to whether the appliance is pr, outlet installed by a qualified electrician.
• To prevent unnecessary risk of fire, electri
ANSI/NFPA, No. 70-Latest Revision (for L personal responsibility and obligation of tl"
• All gas installations must be done in acco
B149 Installation Codes - Latest Revision n
\
\ n Remove the crate wires holding the crate base to the base frame.
This can be done with a screwdriver.
• Loosen the leveling locking nuts and install the vinyl feet.
Review gas requirements on back side of these instructions.
Remove the pipe thread protective cap.
Apply pipe joint compound or about
1 1/2 wraps of Teflon tape over all threaded connections.
NOTE:
Pipe joint compound must be resistant to the action of any liquefied petroleum gas.
O
Connect the gas supply to the dryer.
The dryer pipe is 3/8" N.RT. and adapters may be needed to connect to the house gas supply piping.
Securely tighten the gas line fitting over threads.
DO NOT use excessive force in tightening threads as this may damage internal components.
Turn on the gas supply.
Check all gas connections for leaks using a soap solution.
If bubbles occur, tighten the connections and recheck.
DO NOT use an open flame to check for gas leaks.
m Carefully set the dryer back in an upright position.
•
Review the exhaust section on the reverse side before installing the exhaust system.
Install the ductwork from the dryer to the exhaust hood.
The crimped end of the duct sections must point away from the dryer.
DO
NOT use sheet metal screws when assembling ducting.
These joints should be taped.
Never use plastic flexible exhaust material.
m
Review electrical requirements on back side of these instructions.
BEFORE OPERATING OR TESTING, follow the grounding directions on the reverse side.
U.S. MODELS:
IMPORTANTAll U.S. models are produced for a 3-WIRE SYSTEM CONNECTION.
The dryer frame is grounded to the neutral conductor at the terminal block.
A 4-WIRE
SYSTEM CONNECTION is required for new or remodeled construction, mobile homes, or if local codes do not permit grounding through neutral.
If the 4-wire system is used, the dryer frame cannot be grounded to the neutral conductor at the terminal block.
Refer to the following instructions for 3- and
4-WIRE SYSTEM CONNECTIONS.
Remove the terminal block cover plate.
Tip for tight installations: install a section of exhaust system to the dryer before moving the dryer in place.
Use duct tape to secure this section to the dryer but do not cover louvers in dryer cabinet.
)1
Terminal Block
Cover Plate
(X-X/,..
O
Insert the power cord with a U.L. listed strain relief through the hole provided in the cabinet near the terminal block.
NOTE: a strain relief must be used.
unding conductor can result in a risk of electrical shock.
Check with a qualified electrician or serviceman if you are
)perly grounded.
Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper cat shock or personal injury, all wiring and grounding must be done in accordance with the National Electrical Code
.S.) or the Canadian Electrical code CSA C22.1 - Latest Revision and local codes and ordinances.
It is the e appliance owner to provide adequate electrical services for this appliance.
•dance with the National Fuel Gas Code ANSI/Z2231 - Latest Revision (for the United States) or the CAN/CGA-
(for Canada) and local codes and ordinances.
Do not loosen the nuts already installed on the terminal block.
Be sure they are tight.
Use a 3/8" deep well socket.
3-WIRE SYSTEM CONNECTIONS
If the power cord has terminals, place the terminals over the existing nuts on the posts.
The neutral (white or center wire on power cord) conductor must always be connected to the center (silver colored) post of the terminal block.
Secure in place using the nuts provided in the parts package.
If the power cord does not have terminals, use the cupped washers ahead of the nuts.
Be sure the terminal block nuts are tight, but do not over tighten.
Secure the power cord in position.
Tighten the strain relief screw(s)in order to clamp the strain relief to the cord.
Replace the terminal block cover.
WARNING: If converting from a 4-wire electrical system to a 3-wire, the ground strap must be reconnected to the terminal block support to ground the dryer frame to the neutral conductor.
4-WIRE SYSTEM CONNECTIONS
Remove the ground strap screw from the terminal block support.
Fold the ground strap over so both ends of the ground strap will be attached to the center terminal block post.
Connect the neutral (white) conductor of the cord to the center (silver) post of the terminal block.
Connect the grounding (green) wire of the cord to the terminal block support using the ground strap screw.
Connect the red and black wires of the cord to the outer posts of the terminal block.
Be sure the terminal block nuts are on tight, but do not over tighten.
Secure the power cord in position.
Tighten the strain relief screw(s) in order to clamp the strain relief to the cord.
Replace the terminal block cover.
EXPORT MODELS
Refer to the Additional Instructions Section.
Neutral
Post
Terminal
Block
Support
Neutral
Post
0
0
3-Wire System
,_
3-Wire System
Ground
Strap
J
Ground
Strap
Neutral
Strain relief
Ground
Strap
Screw
Hole for power cord strain relief and
I
I
I
I pi j
_j
I
I
I
I
I
I
I
I
I
I i
1 With a level, check the dryer, and make necessary adjustments to the leveling legs.
Once level, tighten the leveling leg locking nuts with a wrench.
1 The dryer door direction can be reversed.
1. If the dryer is plugged in, unplug from electrical service.
2.
Remove the hinge hole covers and screws.
3. While supporting the door remove 2 screws in the hinges that secure the hinges to the cabinet.
4.
Remove the door by lifting slightly at the hinges and pulling the hinge tabs out of the hinge slots.
5. Move the following parts to the opposite side of the door: 2 hinges and 4 hinge screws, 4 door screws, door strike and screw, inner door cover plate and screw.
6. Attach the door to the opposite side of the cabinet using the 2 counter sunk hinge screws.
(See
8.
.
below.)
Driving the lower hinge screw first will help to align the door and hinges.
Replace the hinge hole covers and screws in the opposite side.
Door Catch Counter Sunk Screw
"-
• 71
-JIi
J
J
_.
i
!1|1
|1
Door
Door
Strike
Door
9.
At this time, make sure all gas, exhaust and electrical connections are complete.
Plug dryer in, and check operation by using the check list below.
1 0, (GAS MODELS ONLY)
The burner may not ignite initially due to air in the gas line.
Allowing the dryer to operate on a heat setting will purge the line.
If the gas does not ignite within five minutes, turn the dryer off and wait 5 minutes.
Be sure the gas supply to the dryer has been turned on.
In order to confirm gas ignition, check the exhaust for heat.
FINAL INSTALLATION CHECK LIST
Dryer is plugged into electrical outlet and is properly grounded.
Exhaust duct work is hooked up and joints taped.
Plastic flexible duct is NOT used.
Use rigid or stiff walled flexible metal vent material.
Dryer is level with all legs firmly on the floor, with the lock nuts tightened.
Vinyl feet have been installed.
Gas Models - gas is turned on, there are no gas leaks.
Dryer runs, heats, shuts off.
Demonstrate use to consumer.
HOUSEHOLD
INSTALLATION ACCESSORIES
• Vent hood - 4" (10.16cm) opening - 059129
• Aluminum pipe - 4" x 24" (10.16cm
x 60.96cm)
- 059130
• Aluminum elbow -4" (10.16cm) - 059131
• Aluminum window plate - 15"x 20" (38.10cm
x
50.80cm) - 4" (10.16cm) hole - 059134
• Flexible aluminum vent duct - 4" (10.16cm) diameter38" (81.28cm) length stretches to
8' (2.44cm) - 304353
• Clamp for flexible aluminum duct - 304630
• Exhaust duct kit for base or left side exhausting
- 33001881
• Rectangular vent kit - 059144
• Dacron lint bag - 311353
• NATURAL to LP conversion kit - 306195
• LP to NATURAL conversion kit - 306204
• Anchor bracket kit - 303740
• Heating element conversion kit, 208V., not for
Canada308590
• Grounding kit - 12001875
• Power cords - 240 v, 30 A
4' - 3-wire - 33001780
5' - 3-wire - 33001822
6' - 3-wire - 33001823
10' - 3-wire - 33001838
4' - 4-wire - 33001781
5' - 4-wire - 33001824
6' - 4-wire - 33001825
For the visually impaired, Braille labels can be placed on the control panel of the appliance.
Check with your local Association for the Blind for information on Braille label makers.
(not U.S. or Canada)
Contact the distributor that sold the appliance or: Maytag International, 8700 W. Bryn Mawr Avenue,
Chicago, Illinois USA 60631, 773-714-0100, for information on product, shipping damage, replacement parts and accessories.
Maytag dryer models manufactured for operation on 60 Hz AC are not designed for use on 50 Hz AC electrical service and conversion of the product from 60 to 50 Hz operation is not recommended.
For additional information on 50 Hz products, contact Maytag International.
The electric service requirements can be found on the data label located on the front of the dryer behind the door.
EXPORT ELECTRIC MODELS
Export electric models are manufactured for operation on either 230/240 volt, 50 Hz or 220 volt, 60 Hz approved electric service.
A two-wire approved electrical service with a 30 ampere fuse or circuit breaker is required.
The dryer must be properly grounded with a ground wire.
IMPORTANT: When permitted by local codes, the dryer electrical supply may be connected by means of a new power supply cord kit, marked for use with clothes dryers, that is agency listed, rated at 240 volts minimum, 30 amperes with two No. 10 copper wire conductors terminated with closed loop terminals, open-end spade lugs with turned up ends or with tinned leads.
Do not reuse a power supply cord from an old dryer.
The power cord or electric supply wiring must be retained at the dryer cabinet with a suitable agency listed strain relief.
2-WIRE AND GROUND SYSTEM CONNECTIONS
Remove the terminal block cover plate.
Insert the power cord with an agency listed strain relief through the hole provided in the cabinet near the terminal block.
Note, a strain relief must be used.
Do not loosen the nuts already installed on the terminal block.
Be sure they are tight.
Use a 3/8" deep well socket.
Secure the power cord ground wire to the terminal block support using the ground screw.
If the power cord has terminals, place the terminals over the existing nuts on the posts.
The neutral wire in power cord must be connected to the center (silver colored) post of the terminal block.
Secure in place using the nuts provided in the parts package.
If the power cord does not have terminals, use the cupped washers ahead of the nuts.
2-Wire and Ground System
Be sure the terminal block nuts are tight.
Secure the power cord in position.
Tighten the strain relief screw(s) in order to clamp the strain relief to the cord.
Replace the terminal block cover.
BEFORE OPERATING OR TESTING, be sure the machine is properly grounded.
Neutral
Post *
EXPORT GAS MODELS
Export gas models are manufactured for operation on either 230/240 volt, 50 Hz or 220 volt, 60 Hz AC approved electrical service with a 15 ampere fuse or circuit breaker.
J
Power
Cord
Ground l Wire
Power cord
Export gas models have been manufactured for use with natural gas having a higher heating value of approximately 1025 BTU per cubic foot.
Conversion to
LP gas with a higher heating value of approximately
2500 BTU per cubic foot must be performed by a qualified service technician.
A conversion kit is available.