Husky H1820F Operator's Manual
Husky H1820F is a portable air compressor with a 20-gallon tank, designed for various inflation and powering tasks. Its powerful motor delivers up to 150 PSI, making it suitable for demanding applications such as inflating tires, powering pneumatic tools, and cleaning with air. The unit features an oil-lubricated pump for enhanced durability and performance, as well as an automatic shut-off mechanism to prevent over pressurization.
पीडीएफ
दस्तावेज़
विज्ञापन
विज्ञापन
<R HUSKY
OPERATOR’S MANUAL
20 GALLON PORTABLE AIR COMPRESSOR
H1820F
CUSTOMER SERVICE
1-866-242-4298
Your air compressor has been engineered and manufactured to Husky's high standard for dependability, ease of opera-
tion, and operator safety. When properly cared for, it will give you years of rugged, trouble-free performance.
A WARNING: To reduce the risk of injury, the user must read and understand the operator's manual before using
this product. |
bs’
Thank you for buying a Husky product.
SAVE THIS MANUAL FOR FUTURE REFERENCE
H1820FOM - Ver 01/08
#
, © IMPORTANT ©
This unit was fully tested and inspected prior to shipment and will operate properly when instructions are followed. Refer to your owner's manual far basic
troubleshooting. To avoid unnecessary return to the store, simply call Compressor Support tell free for additional assistance.
Ba Compressor Support: 1 866-242-4298
Please have your model number a
date for referenca,
NOTICE
¢ Air Compressor will automatically shut off when maximum PSI is reached. When the tank pressure drops to the cut in pressure {low pressure) and the anfofi
switch is in the ON position, the unit will automatically restart.
* On occasion, maximum pressure in tank will remain until next use thus resuiting in a sense of no power. {See bullet above)
* To avoid power foss, overheating and ensure power, use additional air hose rather than extension cords.
e It is the consumer's respansibility to drain oil Jubed units prior to shipment to meet ICC, state and locat fire regulations. |
TABLE OF CONTENTS
E Introduction TEEN
M General Safety Rules ....................— .—.. reee reenicien iros Tere Nerrrenora Terre Nave reerevenereeneoxantoraneacmereReNeToNErerrcenatccarenacrrrarnanerere 9-4
m Specific Safety RUles...............reímecire mer e nee DeRareeaTerarernErerRCUrPeverorerrcnecarereaNanenenTrNeNovENOCFa rar rrertorenanenaracnecenerarete O
E Symbois............ e... reee cecren ener e ener reinar era eee meer ra rss caen ne cr nn ce rrcc arts ner 6-7
_E= Co (1. TO 8
E Glossary of Terms............ee- ee =ecrecccececcoreccnrie econ rr E TErer ANN eEeNr ER EAre nen enArrnrenerea ea eR Ane rear reOUNO nO eraramacaxenrananeNereaTImUFe LENTE ENEE TON r. 9
E Tools Needed.......... ER rr reee reerens er enereerenecenENoacenecaterorrUrereNDaTar y ERmENErONNevaDe DERE NeNDUNENUDOAENTRVECennemenDemearamas 9
M ATU SB tvvirnranussnrarnsssnnransrnsssinrsnsssansrsnnrassenssarssssntorensessssnnesarsssesiesressssssessssnsnssssrnses assis anes ennesssessstaenssnssnmrarmessistnrsenmnnnns 10-11
E Assembly ........e— ee... .eererecorrarenace enterar eLN EEN TO TEFENErAFENEeUErENrerrOIrOv TONO taNcEL TE Ar Tena ren oaeneNveNVenereocaonanENENNCORENANENENNECENEEU E E FONOS ‚ 11-13
MN Operation... .0erieirserrrenicer rece reenere rennecaneaararearerenscrenEoenenErIaNareRANO rn vevenereacanatareanaNE NOTA CEDErraenranececaaanoconeanEncenero 14-15
| ME 11): 15-100. - ONES
№ Troubleshooting........... reseca acera rene renre Nr eDeCeTr ire rneneneronnenerarerDenareneaDenenereereacennememienenenorarenrener recen 17
METE 1) AE 18
E Pneumaátic tOol.............— mesero. 19-20
INTRODUCTION
=
-
-
т
-
=
-
к
-
-
-
я
=
A
ы
=
"
a
=
+
я
+
-
=
“e
=
-
=
-
*
=
-
-
-
=
-
-
-
-
-
я
я
=
=
+
Г
-
"
=
n
“
я
=
=
=
a
"
=
=
This tool has many features for making its use more pleasant and enjoyable. Safety, performance, and dependability
have been given top priority in the design of this product making it easy to maintain and operate.
PRODUCT FOR CONSUMER USE ONLY, Not intended for contractor appiication
A DANGER
This compressor/pump is not equipped and should not be used to supply breathing quality air. Additional equip-
ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing
as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910.134,
Compressed Gas Association, 4221 Walney Road, Fifth Floar, Chantilly, VA 20151-2923, (703) 788-2700,
www.cganet.com. Any such additional equipment has not been examined and no implication of proper use for breath-
ing air is intended or implied.
If this compressor is altered in any way, existing warranties shall be voided. Husky disclaims any liabilities whatsoever
for any loss, personal injury, or damage.
ÁN WARNING:
Read and understand all instructions, Failure to fol-
low all instructions listed below may result in electric
shock, fire, and/or serious personal injury.
SAVE THESE INSTRUCTIONS
WORK AREA
M Keep your work area clean and well lit. Cluttered
benches and dark areas invite accidents. Floor must
not be slippery from wax or dust.
№ Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable lig-
uids, gases, or dust. Power tools create sparks which
may ignite the dust or fumes,
m Keep bystanders, children, and visitors away while
operating tools. Distractions can cause you to lose
control.
M Operate air compressor in an open area at least
18 in. away from any wall or object that could re-
strict the flow of fresh air to ventilation openings.
ELECTRICAL SAFETY
& Avoid body contact with grounded surfaces such as
pipes, radiators, ranges, and refrigerators. There is an
increased risk of electric shock if your body is grounded.
E Don't expose power tools to rain or wet conditions.
Water entering a power tool will increase the risk of
electric shock.
8 Do not abuse the cord. Never use the cord to carry
the tool or pull the plug from an outlet. Keep cord
away from heat, oil, sharp edges, or moving parts.
Replace damaged cords immediately. Damaged
cords increase the risk of electric shock.
E When operating a power too! outside, use an outdoor
extension cord marked “W-A” or "W”., These cords
are rated for outdoor use and reduce the risk of electric
shock.
PERSONAL SAFETY
mM Eye protection which conforms to ANSI specifica-
tions and provides protection against flying particles
both from the FRONT and SIDE should ALWAYS be
worn by the operator and others in the work area
when loading, operating, or servicing this tool. Eye
protection is required to guard against flying fasteners
and debris, which could cause severe eye injury.
MN The employer and/or user must ensure that proper
eye protection is worn. We recommend a Wide Vision
Safety Mask for use over eyeglasses or standard safety
glasses that provide protection against flying particles
both from the front and side. Always use eye protection
which is marked to comply with ANSI 287,1.
GENERAL SAFETY RULES
Additional safety protection will be required in some
environments. For example, the working area may
include exposure to a noise level which can lead to
hearing damage. The employer and user must ensure
that any necessary hearing protection is provided and
used by the operator and others in the work area.
Some enviroments will require the use of head protec-
tion equipment. When required, the employer and user
must ensure that head protection marked to comply
with ANSI Z89.1 is used.
Stay alert, watch what you are doing, and use com-
mon sense when operating a power tool. Do not
use tool while tirad or under the influence of drugs,
alcohol, or medication. A moment of inattention while
operating power tools may result in serious personal
injury.
Dress properly. Do not wear loose clothing or
jewelry. Contain long hair. Keep your hair, clothing,
and gloves away from moving parts. Loose clothes,
jewelry, or long hair can be caught in moving parts.
Do not overreach. Keep proper footing and balance
at all times. Proper footing and balance enables better
control of the tool in unexpected situations.
Use safety equipment. Always wear eye protection.
Dust mask, nonskid safety shoes, hard hat, or hearing
protection must be used for appropriate conditions.
Do not use on a ladder or unstable support. Stable
footing on a solid surface enables better control of the
too! in unexpected situations.
TOOL USE AND CARE
Do not exceed the pressure rating of any compo-
nent in the system.
Protect material lines and air lines from damage or
puncture. Keep hose and power cord away from sharp
objects, chemical spills, oil, solvents, and wet floors.
Check hoses for weak or worn condition before
each use, making certain all connections are se-
cure. Da not use if defect is found. Purchase a new
hose or notify an authorized service center for exami-
nation or repair,
Release all pressures within the system slowly. Dust
and debris may be harmful.
Store idle tools out of the reach of children and
other untrained persons. Tools are dangerous in the
hands of untrained users.
Maintain tools with care. Follow maintenance instruc-
tions. Properly maintained tools are easier to control.
Check for misalignment or binding of moving parts,
breakage of parts, and any other condition that
may affect the tool's operation. If damaged, have
the tool serviced before using. Many accidents are
caused by poorly maintained tools.
GENERAL SAFETY RULES
mM Never point any tool toward yourself or others.
M Keep the exterior of the air compressor dry, clean,
and free from oil and grease. Always use a clean
cloth when cleaning. Never use brake fluids, gasoline,
petroleum-based products, or any strong solvents to
clean the unit, Following this rule will reduce the risk of
deterioration of the enclosure plastic.
SERVICE
E Tool service must be performed oniy by qualified
repair personnel. Service or maintenance performed
by unqualified personnel may result in a risk of injury.
EH Disconnect power supply, open drain valve to de-
compress tank and allow water to drain, and aliow
air compressor to become cool to the touch before
servicing. Turn pressure regulator knob fully clockwise
after shutting off compressor.
Mm When servicing a tool, use only identical replace-
ment parts. Follow instructions in the Maintenance
section of this manual. Use of unauthorized parts or
failure to follow Maintenance instructions may create a
risk of injury.
SPECIFIC SAFETY RULES
Æ Know your power tool. Read operators manual
carefully, Learn its applications and limitations, as well
as the specific potential hazards related to this tool.
Following this rule will reduce the risk of electric shock,
fire, or serious injury.
E Drain tank of moisture after each day’s use.
If unit will not be used for a while, it is best to leave
drain valve open until such time as it is to be used. This
will allow moisture to completely drain out and help
prevent corrosion on the inside of tank.
Wm Risk of Fire or Explosion. Do not spray flammable lig-
uid in a confined area. Spray area must be well ventilat-
ed. Do not smoke while spraying or spray where spark
or flame is present. Keep compressors as far from the
spraying area as possible, at least 15 feet from the
spraying area and all explosive vapors.
® Risk of Bursting. Do not adjust regulator to result in
output pressure greater than marked maximum pres-
sure of attachment. Do not use at pressure greater than
the rated maximum pressure of this compressor.
E If connected to a circuit protected by fuses, use time-
delay fuses with this product.
Bm To reduce the risk of electric shock, do not expose to
rain. Store indoors.
B Inspect tank yearly for rust, pin holes, or other im-
perfections that could cause it to become unsafe.
Never weld or drill holes in the air tank.
E Make sure the hose is free of obstructions or snags.
Entangled or snarled hoses can cause loss of balance
or footing and may become damaged.
m Use the air compressor only for its intended use. Do
not alter or modify the unit from the original design
or function.
B Always be aware that misuse and improper handling
of this tool can cause injury to yourself and others,
EH Never leave a tool unattended with the air hose at-
tached.
® Do not operate this tool if it does not contain a leg-
ible warning label.
B Do not continue to use a tool or hose that leaks air
or does not function properly.
NE Always disconnect the air supply and power supply
before making adjustments, servicing a tool, or when a
tool is not in use.
EH Do not attempt to pull or carry the air compressor
by the hose.
B Your tool may require more air consumption than
this air compressor is capable of providing.
E Always follow all safety rules recommended by
the manufacturer of your air tool, in addition to ali
safety rules for the air compressor. Following this
rule will reduce the risk of serious personal injury.
E Never direct a jet of compressed air toward people
or animals. Take care not to blow dust and dirt
towards yourself or others. Following this rule will
reduce the risk of serious injury.
mB Protect your lungs. Wear a face or dust mask if the
operation is dusty. Following this rule will reduce the
risk of serious personal injury.
E Do not use this air compressor to spray chemicals.
Your lungs can be damaged by inhaling toxic fumes. A
respirator may be necessary in dusty environments or
when spraying paint. Do not carry while painting.
E Inspect tool cords and hoses periodically and, if
damaged, have repaired at your nearest Authorized
Service Center. Constantly stay aware of cord loca-
tion. Following this rule will reduce the risk of electric
shock or fire.
EN Never use an electrical adaptor with this grounded
plug.
NM Check damaged parts. Before further use of the air
compressor or air tool, a guard or other part that
is damaged should be carefully checked to deter-
mine that it will operate properly and perform its
intended function. Check for alignment of moving
parts, binding of moving parts, breakage of parts,
mounting, and any other conditions that may affect
its operation. A guard or other part that is damaged
should be properly repaired or replaced by an au-
thorized service center. Following this rule will reduce
the risk of shock, fire, or serious injury.
M Make sure your extension cord is in good condition,
When using an extension cord, be sure to use one
heavy enough to carry the current your product will
draw. A wire gauge size (A.W.G.) of at least 14 is
recommended for an extension cord 50 feet or less
in length, A cord exceeding 100 feet is not recom-
mended. If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the
cord, An undersized cord will cause a drop in line volt-
age resulting in loss of power and overheating.
EH WARNING: This product contains one or more chemicals
known to the State of California to cause cancer and birth
defects or other reproductive harm,
Wash hands after handling.
@ Save these instructions. Refer to them frequently and
use them to instruct others who may use this air com-
pressor. If you loan someone this tool, loan them these
instructions also.
SYMBOLS
Some of the following symbols may be used on this tool. Please study them and learn their meaning. Proper interpre-
tation of these symbols will allow you to operate the tool better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
y Volts Voltage
A Amperes Current
Hz Hertz Frequency (cycles per second)
A Alternating Current Type of current
[m] Class {I Construction Double-insulated construction
Wet Conditions Alert
Do not expose to rain or use in damp locations.
Read The Operator's Manual
To reduce the risk of injury, user must read and understand
operator's manual before using this product.
Eye Protection
Always wear safety goggles, safety glasses with side shields, of
a full face shield when operating this product.
Safety Alert
Precautions that involve your safety.
Risk of Bursting
Do not adjust regulator to result in output pressure greater than
marked maximum pressure of attachment. Do not use at pres-
sure greater than 155 PSi.
Risk of Fire or Expiosion
Do not spray flammable liquid in a confined area. Spray area
must be well ventilated. Do not smoke while spraying or spray
where spark or flame is present. Keep compressors as far from
the spraying area as possible, at least 15 feet from the spraying
area and all explosive vapors.
Risk of Electrical Shock
Hazardous Voltage: Disconnect from power source before ser-
vicing. Compressor must be grounded.
Hot Surface
To reduce the risk of injury or damage, avoid contact with any
hot surface.
Risk to hearing
Always wear ear protection when using this tool. Failure to do
so may result in hearing loss.
Risk to Breathing
Air obtained directly from the air compressor should never be
used to supply air for human consumption.
SYMBOLS
SYMBOL SIGNAL
The following signal words and meanings are intended to explain the levels of risk associated with this product.
MEANING
4\ DANGER:
Indicates an imminently hazardous situation, which, if not avoided, will
result in death or serious injury,
A | WARNING:
Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury.
A CAUTION:
Indicates a potentially hazardous situation, which, if not avoided, may
result in minor or moderate injury.
(Without Safety Alert Symbol} Indicates a situation that may result in
CAUTION: property damage.
SERVICE A
Servicing requires extreme care and knowledge and WARNING:
should be performed only by a qualified service tech- To avoid serious personal injury, do not attempt to use
nician. For service we suggest you return the product to this product until you read thoroughly and understand
the nearest AUTHORIZED SERVICE CENTER for repair. completely the operator's manual, Save this operator's
When servicing, use only identical replacement parts. manual and review frequently for continuing safe oper-
ation and instructing others who may use this product.
Á WARNING:
The operation of any power tool can result in foreign objects being thrown into your eyes, which can re-
glasses with side shields, or a full face shield when needed, We recommend Wide Vision Safety Mask
В sult in severe eye damage. Before beginning power tool operation, always wear safety goggles, safety
for use over eyeglasses or standard safety glasses with side shields. Always use eye protection which
is marked to comply with ANSI Z87.1.
SAVE THESE INSTRUCTIONS
ELECTRICAL
EXTENSION CORDS
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept the
air compressor's plug. When using the air compressor at
a considerable distance from the power source, use an
extension cord heavy enough to carry the current that the
compressor will draw. An undersized extension cord wiil
cause a drop in line voltage, resulting in a loss of power
and causing the motor to overheat. Use the chart pro-
vided below to determine the minimum wire size required
in an extension cord. Only round jacketed cords listed by
Underwriter's Laboratories (UL) should be used,
"Ampere rating (on air compressor data plate)
0.2.0 2.1-34 35-50 51-70 71-120 12.1-16.0
Cord Length Wire Size (A.W.G.)
25 16 16 16 16 14 14
50° 16 16 16 14 14 12
100° 16 16 14 12 10 —
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
When working with the air compressor outdoors, use an
extension cord that is designed for outside use. This is
indicated by the letters “WA” on the cord's jacket.
Before using an extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
À WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with
a power tool. Failure to do so can result in serious per-
sonal injury.
A WARNING:
Check extension cords before each use. if damaged,
replace immediately, Never use air compressor with a
damaged cord since touching the damaged area could
cause electrical shock resulting in serious injury.
NOTE: Use longer air hoses instead of long extension
cords. Your air compressor will run better and last longer.
ELECTRICAL CONNECTION
This air compressor is powered by a precision built
electric motor. it should be connected to a power sup-
ply that is 120 volts, 60 Hz, AC only (hormal househoid
current). Do not operate this tool on direct current (DC).
A substantial voltage drop will cause a loss of power and
the motor will overheat. If the air compressor does not
operate when plugged into an outlet, double check the
power supply.
SPEED AND WIRING
The no-load speed of the electric motor in this air
compressor is approximately 17,500 rpm. This speed is
not constant and decreases under a [oad or with lower
voltage. For voltage, the wiring in a shop is as important-as
the motor’s horsepower rating. A fine intended only for lights
cannot properly carry a power tool motor. Wire that is heavy
enough for a short distance will be too light for a greater
distance. À line that can support one power too! may not
be abie to support two or three tools.
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current
to reduce the risk of electric shock. This air compressor
is squipped with an electric cord having an eguipment-
grounding conductor and a grounding plug. The plug
must be plugged into a matching outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
Do not modify the plug provided. Hit will not fit the outlet,
have the proper outlet installed by a qualified electrician.
Improper connection of the equipment-grounding con-
ductor can result in a risk of electric shock. The conduc-
tor with insulation having an outer surface that is green
with or without yellow stripes is the equipment-grounding
conductor, If repair or replacement of the electric cord ar
plug is necessary, do not connect the equipment-ground-
ing conductor to a live terminal.
Check with a qualified electrician or service personnel if
the grounding instructions are not completely understood,
or if in doubt as to whether the tool is properly grounded.
Repair or replace a damaged or worn cord immediately.
This air compressor is intended for use on a circuit that
has an outlet like the one shown in figure 1. It also has a
grounding pin like the one shown. This product must be
grounded. -
Never use an electrical adaptor with this grounded plug.
” N
ИЦ
a
O
ИЦ
a
GROUNDING
PIN 120V GROUNDED OUTLET
Fig. 1,
GLOSSARY OF TERMS
Air Filter
Porous element contained within a metal or plastic hous-
ing attached to the compressor cylinder head which
removes impurity from the intake air of the compressor.
Air Tank
Cylindrical component which contains the compressed air.
Check Valve
Device that prevents compressed air from flowing back
from the air tank to the compressor pump.
Cut-in Pressure
The low pressure at which the motor will automatically restart.
This compressor Cut-In pressure is 125 PSI + 5 PSI.
Cut-Off Pressure
The hight pressure at which the motor will automatically shut off,
This compressor Cut-Off pressure is 155 PSI + 5 PSI,
Electric Motor
Device which provides the rotational force necessary to
operate the compressor pump.
Manual On/Off Switch
Control which turns the air compressor on or off, The
pressure switch will not automatically start and control the
compressor unless the manual On/Off Switch is in the ON
(1) position.
NPT (National Pipe Thread)
National Pipe Thread is a U.S. standard for tapered (NPT)
or straight (NPS) threads used to join pipes and fittings.
A thread sealing tape must be used to provide a leak-free
seal on pipe threaded connections,
Pressure Regulator Knob
Regulates the outgoing pressure from the air outlet to the
tool. it is possible to increase or decrease the pressure at
the outlet by adjusting this control knob.
Pressure Switch
Automatically controls the on/off cycling of the compres-
sor. It stops the compressor when the cut-off pressure in
the tank is reached and starts the compressor when the
air pressure drops below the cut-in pressure.
PSI (Pounds Per Square Inch)
Measurement of the pressure exerted by the force of the
air. The actual psi is measured by a pressure gauge on the
compressor.
Pump
Produces the compressed air with a reciprocating piston
contained within the cylinder.
Regulator Pressure Gatige
Displays the current line pressure. Line pressure is adjust-
ed by rotating the pressure regulator knob.
Safety Valve
Prevents air pressure in the air tank from rising over a
predetermined limit.
~ SCFM {Standard Cubic Feet Per Minute)
A unit of measure of air delivery.
Tank Pressure Gauge
indicates the pressure in the air tank.
Thermal Overload Switch
Automatically shuts off the compressor if the temperature
of the electric motor exceeds a predetermined limit.
TOOLS NEEDED
The following tools are needed to tighten the thread ends of the hose to the female connector and coupler, the screws
to the nuts of wheels and rubber foot and the male quick coupler to the air outlet fitting on the compressor.
cd,
TWO ADJUSTABLE WRENGHES (not included)
FEATURES
PRODUCT SPECIFICATIONS
Running HOorsepOwer.............—w. peurnenarencareneneres 1,8 HP LUDNICATION.... ares ascsocrarsanarsne nan cereerenaansraceanaren sense nes Oil-Free
А! ТалК Сарасйу enana nea 20 gal. LES rene … 2.0 in. diameter
Air PressUre …..….….….……ccssereranensessa serres .. 155 psi max, Input... eres 120 Y, 60 Hz, AC om 13.5 Amps
Air Deliveny ...........—.==.——em.—..... „4. 3 SCFM @ 90 psi Net Weight... ereruanonnonencccnrenenenrnecneNTE FEUDO .. 77 lbs.
é A
REGULATOR
HANDLE PRESSURE
ел
TANK N Delo :
PRESSURE LL >> Y € f=
MANUAL
ON/OFF
“a PRESSURE QUICK COUPLER
REGULATOR
KNOB
SAFETY
VALVE
DRAIN VALVE
3/8" RATCHET
WRENCH
ADAPTER
3/8"- 1/2"
En — AIR CHUCK TIRE GAUGE
BLOW GUN
RUBBER TIP NOZZLE— «5
«а CONNECTORS TAPERED NOZZLE —=— aT To
INFLATION NEEDLE -— 6
10
FEATURES
KNOW YOUR AiR COMPRESSOR
See Figure 2.
Before attempting to use this product, familiarize yourself
with all operating features and safety rules,
TOOL AND ACCESSORY KIT
The accessory kit includes: 1 male quick coupler, a blow
gun with a safety nozzie, an inflation adapter, an inflation
needle, 2 inflation nozzles, a tire gauge, an air chuck, 3 male
connectors, a thread sealing tape, a 25’ {x 1") РУС hose,
3/8” Ratchet Wrench, 3/8" - 1/2” Adapter
OIL-FREE UNIVERSAL MOTOR
- Your air compressor features permanently {ubricated
bearings.
PRESSURE REGULATOR KNOB
Use the pressure regulator knob to adjust the amount of
air being delivered through the hose.
REGULATOR PRESSURE GAUGE
The current line pressure is displayed on the regulator
pressure gauge. This pressure can be adjusted by rotating
the pressure regulator knob.
SAFETY VALVE
The safety valve is designed to automatically release air if
the air receiver pressure exceeds the preset maximum.
TANK PRESSURE GAUGE
The tank pressure gauge indicates the pressure of the air
in the tank.
ASSEMBLY
UNPACKING
This product has been shipped completely assembled,
except the rubber foot and the two wheels,
Carefully remove the tools and any accessories from
the box. Make sure that all items listed in the packing
list are included.
Inspect the compressor and tools carefully to make
sure no breakage or damage occurred during shipping.
Do not discard the packing material until you have
carefully inspected and satisfactorily operated the tool.
If any parts are damaged or missing, please call
1-886-242-4298 for assistance.
Á WARNING:
If any parts are missing do not operate the compressor or
air tools until the missing parts are replaced. Failure to do
so could result in possible serious personal injury.
A WARNING:
Do not attempt to modify this tool or create accesso-
ries not recommended for use with this tool. Any such
alteration or modification is misuse and could result
in a hazardous condition leading to possible serious
personal injury.
PACKING LIST
Air Compressor (1)
25" (+ 1”) PVC Hose (1)
3/8” Ratchet Wrench (1)
3/8" - 1/2" Adapter (1)
Infiation Needle (1)
inflation Nozzles (2)
Quick coupler (1)
1/4 in. NPT Connector Fittings (3)
Air Chuck {1)
Tire Gauge (1)
Blow Gun (1)
Safety Nozzle (1)
Inflation Adapter (1)
Thread Sealing Tape (1)
Rubber Foot (1)
Wheels (2)
Screws (3)
Nuts (3)
Washers (5)
Operators Manual (1)
Replacement Parts List (1)
ASSEMBLY
\
ASSEMBLING THE RUBBER FOOT AND @ NUT
WHEELS WASHER 7e
E Mount the rubber foot as shown in (Fig. A).
Tighten firmly with two adjustable wrenches (not included). <
to secure it in position.
um Mount the wheels as shown in (Fig. A).
Tighten firmly with two adjustable wrenches (not included).
to secure the wheels in position.
® | Fi. RUBBER
We =) Foor
ен) _
WASHER >. | fl ass
SCREW
12
ASSEMBLY
ATTACHING HOSE AND QUICK COUPLER
Make sure the air compressor is off and unplugged.
Rotate pressure regulator knob fully counterclockwise.
Apply 1 layer of thread sealing tape to the threaded
end of the male coupler and insert into the air outlet
port on the compressor (Fig. 3).
NOTE: Be careful not to allow threads to become
cross-threaded.
At this point insert the nose into the quick coupler
already installed on the compressor (Fig. 4)
Á WARNING:
Do not attach any tools to the open end of the hose
until start-up has been completed.
Bm Firmly grasp the open end of the hose; hold facing
away from yourself and others.
BREAKING IN THE PUMP
See figure 5 - 6
um Check and tighten all bolts, fittings, etc.
№ Turn the pressure regulator knob fully clockwise to
open the air flow.
mu Place the switch in the OFF position and plug in the
power cord,
HB Open the drain valve completely.
MN Turn the air compress ON (1) and run the air
compressor for 10 minutes to break in pump parts,
w Place the switch in the OFF position.
m Close the drain valve.
13
fo в
= A ‘
> OUTLET
| FITTING
MALE
COUPLER
Fig. 3
REGULATOR
PRESSURE GAUGE
am
——
=
PRESSURE
REGULATOR KNOB
SAFETY VALVE
Fig. 5
are
DRAIN VALVE
OPERATION
A WARNING:
Do not allow familiarity with tools to make you careless,
Remember that a careless fraction of a second is
sufficient to inflict serious injury.
A WARNING:
Always wear safety goggles or safety glasses with side
shields when operating power tools. Failure to do so
could result in objects being thrown into your eyes
resulting in possible serious injury.
CAUTION:
Do not use in an environment that is dusty or otherwise
contaminated. Using the air compressor in this type of
environment may cause damage to the unit.
APPLICATIONS
Air compressors are utilized in a variety of air system ap-
plications. Match hoses, connectors, air tools, and acces-
sories to the capabilities of the air compressor.
You may use this tool for the purposes listed below:
B Operating some air-powered tools
B Inflating tires, air beds, sports equipment, etc.
USING THE AIR COMPRESSOR
See Figure 7 - 8.
E Ensure power switch is in the OFF (0) position and air
compressor is unplugged.
E If not already installed, attach hose to compressor as
previously instructed.
® Attach 1/4 in. NPT male connector fitting to accessory
or tool you intend to use.
® insert the other end of the male connector to the quick
coupler on the open end of hose.
Á WARNING:
Always ensure the switch is in the OFF (0) position and
the regulator pressure gauge reads zero before chang-
ing air tools or disconnecting the hose from the air
outlet. Failure to do so could result in possible serious
personal injury.
E Connect the power cord to the power supply.
E Turn the switch ON (1).
B Rotate pressure regulator knob to desired line pres-
sure. Turning the knob clockwise increases air pres-
sure at the outlet; turning counterclockwise reduces air
pressure at the outlet.
14
@ A
THREAD
AIR SEALING HOSE WITH
APE QUICK COUPLER
ris ATTAGHED
4/4 in. NPT
MALE CONNECTOR Fo. 7
BLOWER | INFLATION |
ATTACHMENT | ACCESSORIES |
E CONNECTO | |
MALE CONNECTOR o |
EE
7 1
y rd:
HE af |
HOSE WITH QUICK
COUPLER ATTACHED ДЕНЕК SAFETY NOZZLE
TAPE |
_ Fig. 8,
H Following alt safety precautions in this manual and the
manufacturer's instructions in the air tool manual, you
may now proceed to use your air-powered tool.
A WARNING:
Check the air tool manual to insure the correct air
pressure regulator setting for optimum operation of
your air tools. If you are using an air tooi not originally
included with the air tool kit supplied with this air
compressor, your {ool may require more air consumption
than this air compressor is designed to supply.
Always read your air tool owners manual to match the
correct air supply to your aír too! to avoid damage
to the tool or risk of personal injury.
B if using an inflation accessory, control the amount of air
flow with the pressure requlator knob. Turning the knob
fully counterclockwise will completely stop the flow of
air.
NOTE: Always use the minimum amount of pressure
necessary for your application. Using a higher pressure
than needed will drain air from the tank more rapidly
and cause the unit to cycle on more frequently.
E When finished, always drain the tank and unplug the
unit. Never leave the unit plugged in and/or running
unattended.
DRAINING THE TANK
See Figure 9.
To help prevent tank corrosion and keep moisture out
of the air used, the tank of the compressor should be
drained daily.
To drain:
HE Holding the handle, tilt the compressor toward the
drain valve so that it’s set in a lower position.
Open the drain valve completely.
Keep the compressor tilted until all moisture has
been removed.
Drain moisture from tank into a suitable container.
NOTE: Condensate is a polluting material and should be
disposed of in compliance with local regulations.
if drain valve is clogged, release all air pressure, remove
and clean valve, then reinstall.
Á WARNING:
Unplug the air compressor and release alt air from
the tank before servicing. Failure to depressurize tank
before attempting to remove valve may cause serious
personal injury.
® Turn off drain valve until completely closed.
CHECKING THE SAFETY VALVE
See Figure 10.
À DANGER:
Do not attempt to tamper with the safety valve. Any-
thing loosened from this device could fly up and hit
you. Failure to heed this warning could result in death
or serious personal injury.
The safety valve will automatically release air if the air
receiver pressure exceeds the preset maximum. The valve
should be checked before each day of use by puliing the
ring by hand.
B Turn the air compressor on and allow the tank to fill.
The compressor will shut off when the pressure reach-
es the preset maximum.
Turn the air compressor off,
Pull the ring on the safety valve to release air for twenty
seconds.
Release the ring. Air will stop escaping when the ring
is released at approximately 20 psi. Any continued loss
of air after releasing the safety valve ring indicates a
problem with the safety valve. Discontinue use and seek
service before continued use of the air compressor.
15
DRAIN VALVE
SAFETY
VALVE
Na
À WARNING:
if air leaks below 20 psi after the ring has been released,
or if the valve is stuck and cannot be actuated by the
ring, Do Not use the air compressor until the safety
valve has been replaced. Use of the air compressor in
this condition could result in serfous personal injury.
A WARNING:
When servicing, use only identical Husky replacement
parts. Use of any other parts may create a hazard or
cause product damage.
À WARNING:
Always wear safety goggles or safety glasses with side
shields during power tool operation or when blowing
dust. if operation is dusty, also wear a dust mask.
A WARNING:
Always release all pressure, disconnect from power sup-
ply, and allow unit to cool to the touch before cleaning or
making repairs on the air compressor.
GENERAL MAINTENANCE
Humidity in the air causes condensate to form in the air
tank. This condensate should be drained daily and/or
every hour, using the instructions found in Draining the
Tank.
The safety valve automatically releases air if the air re-
ceiver pressure exceeds the preset maximum. Check the
safety valve before each use following the instructions
found in Checking the Safety Valve.
MAINTENANCE
16
Inspect the tank yearly for rust, pin holes, or other imper-
fections that could cause it to become unsafe.
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use.
Use clean cloths to remove dirt, dust, cil, grease, etc.
À WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or
destroy plastic which may result in serious personal
injury. Electric tools used on fiberglass material, wall-
board, spackiing compounds, or plaster are subject
to accelerated wear and possible premature failure
because the fiberglass chips and grindings are highly
abrasive to bearings, brushes, commutators, etc. Con-
sequently, we do not recommended using this tool for
extended work on these types of materials. However, if
you do work with any of these materials, it is extremely
important to clean the tool using compressed air.
LUBRICATION
All of the bearings in this tool are lubricated with a suffi-
cient amount of high grade lubricant for the life of the unit
under normat operating conditions. Therefore, no further
lubrication of the bearings is required.
TROUBLESHOOTING
Problem
Possible Cause
Solution
Compressor will not run
Loss of power or overheating
No electrical power
Biown shop/house fuse
Shop/house breaker open
Thermal overload open
Pressure switch bad
Tank is full of air
Check for proper use of extension
cord
Check to be sure unit is plugged in
Check fuse/breaker or motor over-
load
Replace shop/house blown fuse
Reset shop/house breaker, determin-
ing why problem happened
Motor will restart when cool
Replace pressure switch
Compressor will turn on when tank
pressure drops to cut-in pressure
Motor hums but cannot run or runs
slowly
Low voltage
Wrong gauge wire or length of exten-
sion cord
Shorted or open motor winding
Defective check valve or unloader
Check with voltmeter
Check for proper gauge wire and
cord length
Take compressor to service center
Take compressor to service center
Fuses blow/circuit breaker trips
repeatedly
Incorrect size fuse, circuit overload
Wrong gauge wire or length of exten-
sion cord
Defective check valve or unloader
Check for proper fuse, use time-
delay fuse, disconnect other electri-
cal appliances from circuit or operate
compressor on its own branch circuit
Check for proper gauge wire and
cord length
Take compressor to service center
Thermal overload protector cuts out
repeatedly
Low voltage
Lack of proper ventilation/room tem-
perature too high
Wrong gauge wire or length of exten-
sion cord
Check with voltmeter
Move compressor to well-ventilated
area
Check for proper gauge wire and
cord length
Air receiver pressure drops when
compressor shuts off
Loose connections (fittings, tubing,
etc.)
Loose drain valve
Check valve leaking
Check all connections with soap and
water solution and tighten
Tighten drain valve
Take compressor to service center
À DANGER:
Do not disassemble check valve
H with air in tank — bleed tank.
Excessive moisture in discharge air
Excessive water in air tank
High humidity
Drain tank
Move to area of less humidity; use air
line filter
Compressor runs continuously
Defective pressure switch
Excessive air usage
Take compressor to service center
Decrease air usage, compressor not
large enough for tool's requirement
Compressor vibrates
Loose mounting bolts
Tighten mounting bolts
Air output lower than normal
Broken inlet valves
Connections leaking
Take compressor to service center
Apply thread sealing tape to fitting
and tighten
17
AIR COMPRESSORS WARRANTY
HUSKY AIR COMPRESSOR LIMITED ONE-YEAR WARRANTY
This product is manufactured by Nu Air Shanghai factory, Ltd, based in Shanghai, China or its North American Operations,
Nu Air USA Corp., Rock Hill, SC, or by other Nu Air Operations worldwide. The trademark is licensed from HUSKY.
All warranty communications about this HUSKY model should be directed to air compressor support at (toll free)
1-866-242-4298.
WHAT IS COVERED UNDER THIS LIMITED ONE-YEAR WARRANTY
This warranty covers defects in workmanship or materials in this HUSKY air compressor for the one-year period from the
date of purchase. This warranty is specific to thus air compressor model. Warranties for other HUSKY products may vary.
HOW TO OBTAIN SERVICE
To obtain service for this HUSKY air compressor you must return it, freight prepaid, to a service center authorized to repair
HUSKY air compressors. You may obtain the location of the service center nearest you by calling (toll free) 1-866-242-
4298. When requesting warranty service, you must present the proof of purchase documentation, which includes a date
of purchase. The authorized service center will repair any faulty workmanship, and either repair or replace any defective
part, at Nu Air's option at no charge to you.
WHAT IS NOT COVERED
This warranty applies only to the original purchaser at retail and may not be transferred. This warranty does not cover
normal wear and tear or any malfunction, failure or defect resulting from misuse, abuse, neglect, alteration, modification
or repair by other than a service center authorized to repair HUSKY branded air compressors. Expendable materials,
such as oil, filters, etc. are not covered by this warranty. This warranty does not apply to this compressor used in industrial
applications or for rental purposes. NU AIR MAKES NO WARRANTIES, REPRESENTATIONS OR PROMISES AS TO
THE QUALITY OR PERFORMANCE OF ITS AIR COMPRESSORS OTHER THAN THOSE SPECIFICALLY STATED
IN THIS WARRANTY. HUSKY MAKES NO WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED,
INCLUDING AS NOTED BELOW.
ADDITIONAL LIMITATIONS
To the extent permitted by applicable law, all implied warranties, including warranties of MERCHANTABILITY or FITNESS
FOR A PARTICULAR PURPOSE, are disclaimed. Any implied warranties, including warranties of merchantability or
fitness for a particular purpose, that cannot be disclaimed under state law are limited to one year from the date of
purchase. Nu Air is not responsible for direct, indirect, incidental, special or consequential damages. if this air compressor
is used for commercial purposes, the warranty will apply for ninety (90) days from the date of purchase. Some states do
not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or
consequential damages, $0 the above limitations may not apply to you. This warranty gives you specific legal rights, and
you may also have other rights, which vary from state to state.
TOOL WARRANTY
1 YEAR LIMITED WARRANTY
If within one year from the date of purchase, this Husky air tool product fails due to a defect in materials or workmanship,
please immediately contact Product Support at 1-866-242-4298 (8am to 5pm EST, M-F, except normal Holidays). Do
not return the air tool to the store. Please be prepared to send the product, postage prepaid, along with a copy of the
dated first owner purchase receipt with the compressor model that included the air tool circled to: Nu Air USA, Attention:
Air Tooi Direct Replacement Dept., 1623 Cedar Line Drive, Rock Hill, SC 29730. A defective product will be promptly
replaced with a new one of equal or greater value, This warranty excludes incidental/consequential damages and failures
due to misuse, abuse or normal wear and tear. This warranty gives you specific rights, and you may also have other
rights, which vary, from state to state. Please call 1-866-242-4298 for details.
18
<R HUSKY
OPERATOR'S MANUAL
PNEUMATIC TOOL FOR H1820F
WARNING: To reduce the risk of injury, the user must read and understand the operator's manual before
using this product,
SPECIFIC SAFETY RULES
Always wear safety gloves and shoes when using the air
ratchet wrench.
During work, always wear suitable work clothes. Do not
wear loose clothing or ties.
Always wear ear protectors when using the air ratchet
wrench,
Disconnect the air hose before changing or adjusting any
sockets.
Avoid prolonged exposure to vibration.
OPERATION
Technical data
Model No.: 9045610
Recommended Working Pressure: ...........—«——..90 PSI
Max. Operating Pressure: .............—m—m—.o 135 PSI
Socket SUpport: ........—— ..— e. merece ee E
1) Attach 4 in, NPT male connector fitting (A) to the air
iniet (E) of the too! (Fig. 1).
NOTE: Apply thread sealing tape on all threaded
connections.
2) The ratchet wrench is provided with a 3/8" - 1/2"
adapter (B) that accepts the 1/2” sockets included in
the kit (Fig. 2).
3) Connect the ratchet wrench to the compressor as
explained in the Compressor manual at chapter
“OPERATION - USING THE AIR COMPRESSOR".
4) Use the compressor regulator to adjust to the
recommended working pressure for the task to be
performed.
5) Ensure the direction of rotation is correct before
operation. Set the selector to the “F” position
(Forward - clockwise) to tighten. Set the selector
to the “R" position (Reverse - counterclockwise) to
loosen (Fig. 3).
Reverse the procedure if the threads are left-handed,
6) Operate the tool by depressing the ‘lever’ (C) on the
handle (Fig. 3).
MAINTENANCE
After each use, always lubricate air inlet (E) making sure
that the {ubricant penetrates inside the accessory (Fig. 1).
Connect the air tool to the air supply. Run the air tool for
few seconds.
After use, always store the pneumatic tool in a dry, clean
environment. Do not use solvents, flammable or toxic
liquids for cleaning.
20
3/8” RATCHET WRENCH
THREAD
SEALING
TAPE
">
/
डाउनलोड
बस एक दोस्ताना अनुस्मारक. आप दस्तावेज़ को यहीं देख सकते हैं. लेकिन सबसे महत्वपूर्ण बात, हमारे एआई ने इसे पहले ही पढ़ लिया है. यह जटिल चीजों को सरल शब्दों में समझा सकता है, किसी भी भाषा में आपके सवालों के जवाब दे सकता है और सबसे लंबे या सबसे जटिल दस्तावेजों को भी जल्दी से नेविगेट करने में आपकी मदद कर सकता है.
विज्ञापन