OmniLogic
Automation and Chlorination
Installation Manual
Contents
Before You Begin........................1
Overview....................................1
Preparing Pool/Spa Water..........4
Mounting Equipment.................6
Plumbing...................................9
Wiring.......................................13
System Startup.........................23
Configuration Wizard................24
HLBASE
092472 RevA
Hayward Pool Products
620 Division Street, Elizabeth NJ 07207
www.hayward.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
•
READ AND FOLLOW ALL INSTRUCTIONS
• WARNING - To reduce the risk of injury, do not permit children to use this product, unless they are closely supervised at all times.
• A wire connector (bonding lug) is provided on this unit to connect a minimum No.
8 AWG (8.4 mm²) (No. 6 AWG in Canada) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
• A green colored terminal or a terminal marked G, GR, Ground, or Grounding is located inside the supply terminal box or compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electrical supply service panel with a continuous copper wire equivalent in size the circuit conductors supplying this equipment.
• WARNING: Disconnect all AC power during installation.
• WARNING: Water in excess of 100 degrees Fahrenheit may be hazardous to your health.
• One bonding lug for US models (two for Canadian models) is provided on the external surface. To reduce the risk of electric shock, connect the local common bonding grid in the area of the swimming pool, spa, or hot tub to these terminals with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG
Canada.
•
SAVE THESE INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Hayward could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio / TV technician for help.
Industry Canada Statement
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
The term “IC” before the certification / registration number only signifies that the Industry Canada technical specifications were met.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Table of Contents
Introduction
Installation Steps...............................................................3
Preparing
General Water Chemistry...................................................4
Pool/Spa Water Salt..................................................................................5
Mounting
Equipment
Plumbing
OmniLogic Enclosure........................................................6
Temperature Sensors........................................................7
Optional Chlorination.......................................................8
Optional HL-CHEM Sensing Kit........................................8
Optional AQL-CHEM2 pH Dispensing................................8
Optional HLWALLMOUNT.................................................8
Optional HLWLAN...........................................................8
Optional Valve Actuators.................................................8
Pool/Spa Configuration......................................................9
TurboCell.......................................................................12
Flow Switch....................................................................12
Electrical
Wiring
Final Steps
Startup and
Configuration
Warranty
Main Service...................................................................14
Grounding and Bonding...................................................14
Circuit Breaker Installation and Wiring..............................14
General Purpose Outlet...................................................14
OmniLogic Power............................................................14
Pool Equipment Connection Table....................................15
High Voltage Pool Equipment...........................................16
Low Voltage Wiring..........................................................17
Before Startup.................................................................23
Startup and Configuration Wizard.....................................24
Bodies of Water.........................................................25
Filter Pumps......................................................25
Heaters.............................................................26
HL-CHEM..........................................................28
Chlorinator.........................................................29
Cleaners............................................................29
Water Features..................................................30
ColorLogic Lights...............................................31
Other Lights......................................................31
Accessories.......................................................31
Sensors....................................................................32
Backyard Accessories...............................................33
Interlocks.................................................................33
OmniLogic Limited Warranty............................................35
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Before you Begin
What’s Included
Before attempting to install the OmniLogic system, check that the following components have been included in the package:
•
OmniLogic Electronics Unit
•
(3) Temperature sensors with 15 ft. (5m) cable, hose clamp
What’s NOT Included
Some of the additional items that you may need to complete an installation include:
Circuit breakers
None are included with control—see page 14 and inside door label for suitable breakers
Wire
4-conductor cable for connection to optional wired terminal(s)
Wire/conduit for 125A service from main panel to OmniLogic
Wire/conduit for filter pump and other high voltage loads
Wire for remote heater control and other low voltage devices
Wire for bonding
Miscellaneous
Optional utility electrical outlet and weatherproof cover (for mounting on side of OmniLogic)
Mounting hardware (screws, bolts, etc.) for mounting OmniLogic and remote terminals
Valve Actuators (to automate valve functions)
Accessory Products - Order Separately
T-CELL-3
T-CELL-9
T-CELL-15
P-KIT
HL-CHEM
HLRELAYBANK
HLIOEXPAND
HLDIMMER
HLRELAY
HLWLAN
HLWALLMOUNT
GVA-24
V&A-xx
Chlorinator Cell - generates chlorine for pools up to 15k gallons
Chlorinator Cell - generates chlorine for pools up to 25k gallons
Chlorinator Cell - generates chlorine for pools up to 40k gallons
Chlorination plumbing kit containing flow switch and cell unions
ORP & pH Sensing Kit for monitoring and controlling pool chemistry
Additional relay pack adds 4 high voltage relays
Input/Output Expander Board adds 4 additional sensor/external inputs, 4 heater/low voltage outputs, and 4 actuator outputs
Light Dimmer Relay Kit
Single high voltage relay kit
Wireless home network connectivity - eliminates the need to hard wire the OmniLogic to the home’s router/access point
Wired Wall Mount Remote Terminal
Actuator
Valve & Actuator (xx=1P (1.5” pos. seal), -2P (2” pos. seal)
NOTE: Before installing this product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios/decking, a qualified stone installation specialist should be consulted regarding the appropriate type, installation, sealant (if any) and maintenance of stone used around a saline pool with electronic chlorine generator in your particular location and circumstances.
NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged especially in arid regions where pool water is subject to excessive evaporation and is not commonly diluted with fresh water. Dry acid can cause a buildup of by-products that can damage your chlorinator cell.
Overview
The OmniLogic HLBASE is a multifunction pool automation control that is expandable to meet all your needs and fully manage your pool/spa system. The OmniLogic can control pumps, valves, lighting, heaters, pool chemistry and more. It offers the next generation of technology to manage pool/spa equipment and the backyard experience. Using a touchscreen interface and network connectivity, the OmniLogic gives the user complete control over both automation and chlorination of their pool and spa.
Although the OmniLogic is easy to use, it is important to completely read through this manual before attempting to install, configure or operate the unit.
1
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Features
The standard Hayward HLBASE OmniLogic offers the following features:
• control up to 4 high voltage (120/240V) relays to control pumps, pool lights, yard lights, water features, chemical dispensers and more
• control up to 4 automatic valve actuators including pool and spa valves, water feature valves, cleaner valves and more
• control up to 4 heaters or low voltage equipment including gas heaters, electric heat pumps, and solar heaters as well as various low voltage devices
• inputs for up to 4 temperature sensors or external input devices
• ethernet port for wired connection to the home’s router/access point allowing communication to devices on the home network or on the web
• 100A electrical subpanel that can accommodate up to 12 circuit breakers
• connection for Hayward TurboCell used to generate chlorine
• connection for flow switch used to detect water flow
• input for ORP and pH sensing (HL-CHEM)
• connection for Expansion Panel if more than on OmniLogic is required
Optional accessories (page 1) can expand the functionality of the HLBASE. Determine your needs and select the necessary HLBASE accessories before you begin the installation.
Computers
Android and IOS
Mobile devices
Optional Wireless
Remote Terminals
Optional Wired
Remote Terminals
If using HLIOEXPAND, up to
8 Temperature Sensors and External Input devices
Optional pH and ORP
Flow Switch up to 10 120/240V Relays (using HLRELAYBANK) up to 8 24V Actuators (using HLIOEXPAND) up to 8 Heaters and Low
Voltage devices (using HLIOEXPAND) optional Chlorinator Cell
2
240 VAC
Power
Circuit Breaker
Subpanel
240 VAC
Power
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS up to 10 120/240V Relays up to 8 24V Actuators
Chlorinator Cell
Circuit Breaker
Subpanel
Chlorination
When used with an optional Hayward TurboCell and P-KIT, the OmniLogic can generate all the chlorine needs for pools up to 40,000 gallons (150,000 liters), or the needs of most commercial pools up to 25,000 gallons (95,000 liters). If enabled (see Configuration Wizard), this operation requires a low concentration of salt (sodium chloride) in the pool/spa water. The OmniLogic automatically converts salt into free chlorine which kills bacteria and algae in the pool/spa. Chlorine will revert back to sodium chloride after killing bacteria. These reactions will continuously recycle, virtually eliminating the need to add sanitizing chemicals to your pool/spa. The only time you may need to add more salt to the pool/spa is when water is replenished due to backwashing, draining, or splashing (not evaporation). The actual amount of chlorination required to properly sanitize a pool varies due to bather load, rainfall, temperature, and the pool’s cleanliness.
Installation Steps
DANGER of Death, Injury or Property Damage if procedure not followed. Dead front removal is required for this installation. Power to the OmniLogic panel MUST be shut off before the dead front is removed. This means a complete shutdown of power to the entire OmniLogic panel.
Details on each installation step are presented on the following pages:
1. Prepare the pool water (page 4)
General Water Chemistry
Salt
2. Mounting the equipment (page 6)
OmniLogic main unit
Temperature sensors
Remote display/keypad (optional)
Valve actuators (if applicable)
3. Plumbing (page 9)
General Pool Equipment
TurboCell
Flow Switch
4. Electrical Wiring (page 13)
Main service
Grounding and bonding
Circuit breakers
OmniLogic power
High Voltage pool equipment
Low voltage wiring (temperature sensors, flow switch, etc.)
5. System Startup and checkout (page 24)
NOTE: If replacing a Pro Logic Controller using networked ColorLogic Lights, the lights must be put into “Standalone” (default) mode before disconnecting the
Pro Logic. The OmniLogic can only control ColorLogic lights in “Standalone” mode.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3
Preparing Pool/Spa Water
General Water Chemistry
Salt is required only if you are using the chlorinator features on the OmniLogic Control Center. If you are NOT using the chlorinator, it is recommended that you follow all of the other chemistry recommendations besides salt.
Water Chemistry
This table summarizes the levels that are recommended by the Association of Pool and Spa Professionals (APSP). The only special requirements for the
OmniLogic are the salt level and stabilizer.
Saturation index
The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool water “balance”. Your water is properly balanced if the Si is 0 ±0.2. If the Si is below -0.2, the water is corrosive and plaster pool walls will be dissolved into the water. If the Si is above +0.2, scaling and staining will occur. Use the chart below to determine the saturation index.
Si = pH + Ti + Ci + Ai - 12.1
ºC ºF
Ti
Calcuim
Hardness
Ci
Total
Alkalinity
Ai
12
16
19
24
53
60
66
76
.3
.4
.5
.6
75
100
125
150
200
250
400
600
1.5
1.6
1.7
1.8
1.9
2.0
2.1
75
100
125
150
200
250
400
600
1.9
2.0
2.1
2.2
2.3
2.4
2.5
29
34
39
84
94
103
.7
.8
.9
300
800
2.2
2.4
2.5
300
800
2.6
2.8
2.9
How to use: Measure pool pH, temperature, calcium hardness, and total alkalinity. Use the chart above to determine Ti, Ci,and
Ai from your measurements. Insert values of pH, Ti, Ci and Ai into the above equation. If Si equals .2 or more, scaling and staining may occur. If Si equals -.2 or less corrosion or irritation may occur.
-.2
0 .2
CORROSIVE SCALING
OK
The pool’s chemistry must be balanced BEFORE activating the OmniLogic’s optional chlorinator function. NOTE: If the pool does not have new water, add metal remover and non-copper based algaecide to the pool, per manufacturer’s instructions. This ensures a quick, troublefree transfer to the OmniLogic system.
4
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Salt
(When using optional chlorinator function)
Use the chart at the bottom of the page to determine how much salt in pounds or (Kgs) should be added to reach the recommended levels. Use the Pool Sizing
Formula below (measurements are in feet/gallons and meters/liters) if pool size is unknown.
The operating salt level is between 2700-3400 PPM (parts per million) with 3200 PPM being optimal. Before adding any salt, test the salt level. This is especially important for retrofit installation to older pools where all of the chlorine added to the pool over time is ending up as salt. If the level is low, determine the number of gallons in the pool and add salt according to the chart below. A low salt level will reduce the efficiency of the sanitization and result in low chlorine production. A high salt level can cause the OmniLogic to stop chlorinating. The salt in your pool/spa is constantly recycled and the loss of salt throughout the swimming season should be minimal. This loss is due primarily to the addition of water because of splashing, backwashing, or draining (because of rain). Salt is not lost due to evaporation.
Type of Salt to Use
It is important to use only sodium chloride (NaCl) salt that is greater than 99.0% pure. This can be found at most pool stores in 40-80 lb. bags labeled “for use in swimming pools”. Alternatively, use common food quality or water softener salt that is at least 99.0% pure. It is also acceptable to use water conditioning salt pellets, however, it will take longer for them to dissolve. Do not use rock salt, or salt with more than 1% of yellow prussiate of soda, salt with anti-caking additives, or iodized salt.
5
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
How to Add Salt
For new plaster pools, wait 10-14 days before adding salt to allow the plaster to cure. Turn the circulating pump on and add salt directly into the pool. Brush the salt around to speed up the dissolving process—do not allow salt to pile up on the bottom of the pool. Run the filter pump for 24 hours with the suction coming from the main drain (use pool vacuum if there is no main drain) to allow the salt to evenly disperse throughout the pool. The salt display may take 24 hours to respond to the change in salt concentration.
Always check stabilizer (cyanuric acid), when checking salt. These levels will most likely decline together. Use the chart below to determine how much stabilizer must be added to raise the level to 40 ppm.
Mounting the Equipment
OmniLogic Enclosure
The OmniLogic is contained in a raintight enclosure that is suitable for outdoor mounting. The control must be mounted a minimum of 6 ft. (2 meters) horizontal distance from the pool/spa (or more, if local codes require). The OmniLogic is designed to mount vertically on a flat surface with the knockouts facing downward.
Because the enclosure also acts as a heat sink (disperses heat from inside the box), it is important not to block the four sides of the control. Do not mount the
OmniLogic inside a panel or tightly enclosed area.
When selecting a location, note that the standard cables supplied with the included flow switch and temperature sensors, as well as optional accessories like
Hayward TurboCells and actuators are all 15 ft. (5m) long.
The OmniLogic weighs close to 60lbs. and will require two people to position and install. Select the proper location and mounting hardware given the size and weight of the unit. The OmniLogic mounting brackets require a total of 6 mounting bolts to fasten the OmniLogic to the mounting surface.
Note that there is a heatsink on the back of the enclosure. Refer to the following information regarding the OmniLogic heatsink:
In all cases the heat sink on the back of the OmniLogic panel should not contact the wall behind the panel. This restricts air flow and makes the heat sink less efficient. A minimum separation of 1/8” (except for vinyl siding) should be maintained between any heat sink pin and the siding on the wall behind the enclosure.
In the case of a flat wall the mounting flanges on the enclosure ensure that the minimum clearance is maintained. For shingles, clapboards or other siding with a non-flat profile, the installer must ensure the minimum separation. Refer to the diagram on page 7.
Special Installation Instructions for Vinyl Siding
IMPORTANT: The heat sink on the back of the OmniLogic panel cannot be allowed to contact vinyl siding; during normal chlorinator operation the heat sink pins get warm enough to deform vinyl siding on contact. An increased minimum separation of 3/8” should be maintained between any heat sink pin and the vinyl siding behind the enclosure.
6
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Minimum Clearance between heatsink and mounting surface - 1/8”
For Vinyl Siding - 3/8”
Temperature Sensors
Three sensors are included with the OmniLogic. A water sensor and an air sensor must be installed at all times for proper operation. A solar sensor is required if the solar function is enabled.
Water Sensor
This sensor is used to measure the pool/spa temperature and is installed in the filtration plumbing after the filter but before either the solar or conventionally fueled heaters—refer to the plumbing overview diagram.
1. Drill a 3/8” (10mm) diameter hole in the PVC piping and remove all chips and burrs.
2. Insert sensor until O-ring collar sits flush on the hole.
3. Position hose clamp over the sensor and gently tighten until O-ring makes an adequate seal. Do not overtighten.
Air Sensor
Mount the air sensor outdoors. IMPORTANT: The air sensor must not be mounted in direct sunlight.
Solar Sensor
For solar applications, mount the sensor near the solar collector array so that it is exposed to the same sunlight as the collectors. Use additional cable (20 AWG) if necessary.
7
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Optional Chlorination Function
The OmniLogic model requires the use of a chlorinator cell and plumbing kit to provide pool chlorination. These items are not included with the OmniLogic and can be purchased separately at your local Hayward dealer. Choose a chlorinator cell model based on the size of your pool. The following models are available:
T-CELL-15 for pools up to 40,000 gallons
T-CELL-9 for pools up to 25,000 gallons
T-CELL-3 for pools up to 15,000 gallons
In addition to the chlorinator cell, a plumbing kit (P-KIT) must be purchased. This kit contains the cell unions and flow switch. Refer to pages 12 and 23 for plumbing and wiring instructions.
Optional HL-CHEM Sensing Kit
The HL-CHEM is an ORP and pH sensing kit for the OmniLogic. When chlorination is enabled (requires chlorinator cell and P-KIT), the OmniLogic senses the pool’s ORP and pH levels and generates the correct amount of chlorine to keep your pool properly sanitized. Wiring and plumbing requirements for the HL-CHEM should be considered before installing the OmniLogic. Refer to the HL-CHEM manual for specific installation information.
Optional AQL-CHEM2 CO2 Dispensing Kit
The AQL-CHEM2 is a CO2 dispensing device that connects directly to the OmniLogic. When used with an HL-CHEM, the OmniLogic will sense the pool’s pH level and automatically dispense the correct amount of CO2 to control the pool’s pH to the desired level. Wiring and plumbing requirements for the AQL-CHEM2 should be considered before installing the OmniLogic. Refer to the AQL-CHEM2 manual for specific installation information.
Wired Remote Terminal
Hayward offers an optional wired remote terminals for the OmniLogic, giving you the ability to control your pool’s functions from a remote location, away from the pool pad. The OmniLogic can also be controlled remotely by various internet enabled devices such as phones, tablets and PCs.
HLWALLMOUNT
The HLWALLMOUNT is a wired touchscreen remote terminal designed to be mounted up to 500’ away (depending on cable gauge) from the OmniLogic. The
HLWALLMOUNT must be mounted indoors or in a weather protected area (rain should never touch the unit). It can mount over a single gang electrical utility box or can be mounted directly onto any wall surface. When selecting a mounting location, refer to the HLWALLMOUNT manual for more information.
Networking and Web Enabled Devices
The OmniLogic offers ethernet connectivity to the web through the home’s network. Once connected, web enabled devices such as a PC, laptop, tablet or phone can be used to control and monitor the OmniLogic. For web connectivity, an ethernet cable must be run from the OmniLogic to the router or access point or a wireless connection can be made to the home’s router using an optional HLWLAN.
HLWLAN
If running ethernet cable from the home’s router/access point to the OmniLogic is impractical, an optional HLWLAN can be used. The HLWLAN is a 802.11b/g/n transceiver kit that can make a wireless connection up to 250’ to the home’s router/access point preventing the need to run cable for web access. Refer to the
HLWLAN Owner’s Manual for wiring and configuration information.
Optional Valve Actuators
For optional actuators used with the OmniLogic—note that the internal cams in the actuator may also have to be adjusted depending on the way the actuator is mounted on the valve and the desired valve action.
RETURN
SUCTION
OUT OUT IN IN
8
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Plumbing
Pool/Spa System Configuration
These systems use a single filter pump and filter. Pool or spa operation is controlled by two 3-way valves (suction and return). Refer to the diagram below.
HIGH VOLTAGE
LIGHTS
High Voltage Relays
Filter Pump
Lights
Aux 1
Aux 2
CHECK VALVE
POOL/SPA SUCTION
VALVE
FILTER
PUMP
MANUAL
VALVE
MANUAL
VALVE
POOL VACUUM
VALVE
TWO-WAY
VALVE
ENERGY
FILTER
ISOLATED
WATER
FEATURE
Valve Outputs
Pool/Spa Suction
Pool/Spa Return
Valve 3
Valve 4
FILTER
SOLAR BOOST
PUMP
CHECK
VALVE
SOLAR
VALVE
POOL/SPA
TEMPERATURE
SENSOR
SPA
BLOWER
TRANSFORMER
LOW VOLTAGE
LIGHTS
COLOR WHEEL
FIBER OPTIC
LIGHT SOURCE
SOLAR
TEMPERATURE
SENSOR
CHECK
VALVE
HEATER
HEAT
PUMP
CELL
FLOW
SWITCH
HEATER
BYPASS
VALVE
(manual)
MANUAL
VALVE
POOL/SPA
RETURN
VALVE
POOL SWEEP
BOOST PUMP
CHECK
VALVE
WATER
FEATURE
VALVE WATER
FEATURE
PUMP
IN-FLOOR
CLEANER
SKIM
MAIN
DRAIN
PUMP
SPA JET
PUMP
SPA
POP-UP
OVERFLOW
SPILLOVER
POOL
POP-UP
SUCTION
CLEANER
ENERGY
SAVER
PRESSURE
CLEANER
POP-UP
POP-UP
RETURN
JET
VALVE
WATER
FEATURE
PUMP
WATER
FEATURE
NON-BOOST
PRESSURE
CLEANER
PRESSURE
CLEANER
Some important notes regarding standard Pool/Spa systems:
1. The OmniLogic can be programmed to accommodate spa spillover, if desired.
2. A conventional heater (gas or heat pump) and solar can be used to heat both the pool and the spa.
3. If the chlorinator cell is plumbed prior to the pool/spa return valve, then both the pool and the spa can be chlorinated
4. The water sensor should be installed prior to any heater or solar and will display either the pool or the spa temperature, depending on the current operation of the pool. The temperature will only be displayed when the filter pump is running.
5. If any water feature or pressure side cleaner boost pumps are used, be sure to enable the “interlock” feature (see CONFIGURATION for details) to ensure that the pumps operate only when the filter pump is on and the system is in the “pool only” operating mode.
6. The plumbing diagram above is intended to be used as a general guideline and is not a complete plumbing schematic for the pool.
7. The air sensor must be installed if the freeze protection feature is enabled for the filter, valves, chlorinator, other pool functions.
9
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
“Dual Equipment - Separate Heaters” for Pool/Spa Configuration
These systems have 2 complete sets of equipment (filter pump, filter, heater)—1 set for the pool and the other set for the spa. Refer to the diagram below:
High Voltage Relays
Pool Filter Pump
Lights
Spa Filter Pump (Aux 1)
Aux 2 - Aux 6
Valve Outputs
Pool/Spa Spillover
Valve 3
Valve 4
Heater Outputs
Heater 1 (Spa)
Heater 2 (Pool)
HIGH VOLTAGE
LIGHTS
TRANSFORMER
MANUAL
VALVE
FILTER
SOLAR BOOST
PUMP
CHECK
VALVE
SOLAR
VALVE
SOLAR
TEMPERATURE
SENSOR
CHECK
VALVE
HEATER
FIBER OPTIC
LIGHT SOURCE
CELL
FLOW
SWITCH
LOW VOLTAGE
LIGHTS
COLOR WHEEL
POOL FILTER
PUMP
POOL SWEEP
BOOST PUMP
MANUAL
VALVE
POOL VACUUM
VALVE FILTER
HEATER
TWO-WAY
VALVE
ENERGY
FILTER
ISOLATED
WATER
FEATURE
PUMP
SPA FILTER
PUMP
SPA
BLOWER
HEATER
BYPASS
VALVE
(manual)
IN-FLOOR
CLEANER
WATER
FEATURE
VALVE
WATER
FEATURE
PUMP
SUCTION
CLEANER
SKIM
MAIN
DRAIN ENERGY
SAVER
PRESSURE
CLEANER
SPA JET
PUMP
SPA
POP-UP
OVERFLOW
SPILLOVER
POOL
POP-UP
POP-UP
POP-UP
RETURN
JET
VALVE
WATER
FEATURE
PUMP
WATER
FEATURE
NON-BOOST
PRESSURE
CLEANER
PRESSURE
CLEANER
Some important notes regarding the control of Dual Equipment Pool/Spa systems with separate heaters:
1. When dual equipment is selected:
a. The pool filter can be a one, two or variable pump.
b. The spa filter can be a one, two or variable pump.
2. The water sensor should be installed on the pool loop prior to the heater and will display the pool temperature whenever the “Pool Filter” pump is running.
3. The dual equipment spa sensor should be installed on the spa loop prior to the heater and will display the spa temperature whenever the “Spa Filter” pump is running.
4. The OmniLogic can be programmed to accommodate spillover if desired. Note that spillover operation will be automatically suspended whenever the spa filter pump is turned on.
5. The chlorinator cell must be installed in the pool plumbing. If spillover is enabled, then the OmniLogic can chlorinate both the pool and spa (during spillover operation). Otherwise, the OmniLogic will only chlorinate the pool and the spa sanitization will have to be handled manually.
6. If any water feature or pressure side cleaner boost pumps are used, be sure to enable the “interlock” feature (see CONFIGURATION for details) to ensure that the pumps operate only when the “Pool Filter” pump is on and the system is in the “pool only” operating mode.
7. The plumbing diagram on page 9 is intended to be used as a general guideline and is not a complete plumbing schematic for the pool.
10
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
“Dual Equipment - Shared Heaters” for Pool/Spa Configuration
These systems have 2 complete sets of equipment (filter pump, filter) and shared heaters. Refer to the diagram below:
In from POOL
POOL FILTER
PUMP
POOL
FILTER
SOLAR BOOST
PUMP
CHECK
VALVE
SOLAR
VALVE
SOLAR
TEMPERATURE
SENSOR
CHECK
VALVE
HEATER
HEATER
VALVE 1
ELECTROLYTIC
CELL
FLOW
SWITCH
SPA
FILTER
VALVE 2
In from SPA
SPA FILTER
PUMP
Out to POOL
Out to SPA
VALVE 3
Some important notes regarding the control of Dual Equipment Pool/Spa systems with shared heaters:
In the Pool/Spa Config., select:
1. When dual equipment is selected: a. The pool filter can be a one, two or variable pump.
b. The spa filter can be a one, two or variable pump.
c. The heater(s) will be dedicated to the spa whenever the spa filter is on and the spa temperature setting is not off.
2. The water sensor should be installed on the pool loop prior to the heater(s) and will display the pool temperature whenever the “Pool Filter” pump is running.
3. The dual equipment spa sensor should be installed on the spa loop prior to the heater(s) and will display the spa temperature whenever the “Spa Filter” pump is running.
4. The OmniLogic can be programmed to accommodate spillover if desired. Note that spillover operation will be automatically suspended whenever the spa filter pump is turned on.
5. The chlorinator cell and flow switch must be installed in the heater return path. If spillover is enabled, then the OmniLogic can chlorinate both the pool and spa (during spillover operation). Otherwise, the OmniLogic will only chlorinate the pool when the spa does not control the heater(s) and the spa sanitization will have to be handled manually.
6. If any water feature or pressure side cleaner boost pumps are used, be sure to enable the “interlock” feature (see CONFIGURATION for details) to ensure that the pumps operate only when the “Pool Filter” pump is on and the system is in the “pool only” operating mode.
7. The plumbing diagram on page 9 is intended to be used as a general guideline and is not a complete plumbing schematic for the pool.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
11
Optional TurboCell
The TurboCell (used for chlorine generation) must be plumbed AFTER the filter and heater. If installed on a pool/spa combination system, the cell must be plumbed BEFORE the pool/spa return valve in order to allow proper chlorination of both the pool and the spa. Refer to plumbing diagram below:
FLOW
SWITCH
TurboCell
TurboCell
12” min
Flow Switch before Cell
VALVE
Flow Switch after Cell
12” min
VALVE
POOL
SPA
FLOW
SWITCH
SPA
POOL
The cell may be mounted vertically or horizontally, and water can move in either direction through the cell. Install using the 2” unions provided. Tighten unions
BY HAND for a watertight seal. For systems with 1½“ plumbing use adapters (provided by installer).
Flow Switch (supplied with P-KIT)
A Hayward flow switch is required if using the optional TurboCell for chlorination or an AQL-CHEM2 for pH dispensing. The flow switch is a safety device that ensures that water is flowing through the cell before the OmniLogic starts to generate chlorine or dispenses acid.
The flow switch must be plumbed in the same section of plumbing as the TurboCell. Failure to properly install the flow switch can result in explosive gases accumulating in the pool plumbing system.
IMPORTANT: There must be at least a 12” (30cm) straight pipe run before (upstream) the flow switch. If the switch is plumbed after the cell, the cell can by counted as the 12” (30cm) of straight pipe.
IMPORTANT: To ensure proper operation, verify that the arrow on the flow switch points in the direction of water flow.
12
Electrical Wiring
The OmniLogic requires both high and low voltage connections. Low voltage connections will be made to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as providing direct input power to the Control Center. Always:
-Ensure that Power is disconnected prior to performing any wiring
-Follow all local and NEC (CEC if applicable) codes
-Use copper conductors only
-Remove power to the OmniLogic subpanel before removing the deadfront
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
13
Main Service (Power to the Circuit Breaker Subpanel)
The OmniLogic circuit breaker subpanel can accommodate up to 12 circuit breakers and is rated for 125A service. Run properly rated conductors (L1, L2, N, and ground) from the primary house electrical panel to the main power connections on the OmniLogic circuit breaker base. The connection at the main house panel should be to a 240VAC circuit breaker rated at 125A maximum.
Grounding and Bonding
Connect a ground wire from the primary electrical panel to the OmniLogic ground bus bar. Also ground each piece of high voltage (120 or 240VAC) equipment that is connected to the OmniLogic control relays or circuit breakers. The OmniLogic should also be connected to the pool bonding system by an 8AWG (6AWG for Canada) wire. A lug for bonding (2 for Canada) is provided on the outside/bottom of the OmniLogic enclosure.
Circuit Breaker Installation and Wiring
Circuit breakers are to be supplied by the installer. Refer to the circuit breaker chart below for a list of suitable circuit breakers that can be used. Follow the code and the circuit breaker manufacturer’s rating requirements regarding the size and temperature rating for wiring. Note that some pool equipment may be required to be connected to ground fault circuit breakers—check local and NEC (CEC) codes.
General Purpose Outlet
If desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in the knockout on the lower right side of the OmniLogic enclosure.
Per code, use a GFCI type receptacle or a standard receptacle protected by a Ground Fault Circuit Breaker.
OmniLogic Power
The OmniLogic requires 120VAC, 5A power to operate the control logic circuits and the chlorinator. This power should be connected to a dedicated circuit breaker.
!
WARNING: 120VAC only (permanent damage will occur if connected to 240V)
14
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Connection Table
The HLBASE includes 4 high voltage relays, 4 low voltage/heater relays, 4 valve outputs and 4 temperature sensor inputs. Additional relays and inputs/outputs can be added using an HLRELAYBANK, HLIOEXPAND or HLRELAY(s) (see Accessories) . When wiring pool equipment to the OmniLogic, keep a record of all connections. You’ll need to record which input/output is used and what equipment is attached. To aid in this process, use the table below. To identify the various inputs/outputs, refer to the diagram on the side of the table. After attaching a equipment to the OmniLogic, fill in the appropriate information in the table.
Connection Table
HVR5
HVR8
HVR6 HVR7
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
15
High Voltage Wiring
High Voltage Relays - (120/240V) Pool Equipment
All OmniLogic relays are double pole (they make/break both “legs” of 240V circuits) and are rated at 3HP/30A at 240V (1½HP/30A at 120V). Refer to the diagram below for typical relay wiring. Record all connections using the table on page 15.
!
WARNING: Do not use the OmniLogic to control an automatic pool cover. Swimmers may become entrapped underneath the cover.
Two speed filter pump
Requires two relays for proper operation of both speeds. NOTE: When selecting relays for two speed operation, note that both relays must be within the Relay
Bank (HLRELAYBANK) or neither relay should be within the Relay Bank. The diagram below shows the pump connected to relays outside of the Relay Bank.
16
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Lights
A ground fault circuit breaker (GFCB) must be used to supply power for high voltage pool/spa lighting. Low voltage lights will require an external transformer.
For lighting systems that have both a light source and color wheel, connect the light source to one relay and then connect the color wheel to a different relay.
Hayward Variable Speed Pump
Proper installation of a Hayward Variable Speed Pump (VSP) includes high voltage input wiring, low voltage communication wiring, and menu configuration/ settings. The OmniLogic can control up to 2 Hayward TriStar VSPs and 8 EcoStar VSPs. Refer to the diagram below for proper 220VAC input wiring to the
VSP. Refer to “Low Voltage Wiring” section in this manual for information on communication wiring. Refer to the VSP manual(s) for detailed wiring information.
pH Dispense Output
When used with a Hayward HL-CHEM, a pH dispensing device may be used. The HL-CHEM is an ORP and pH sensing kit that is offered as an accessory for
OmniLogic pool automation controls. The HL-CHEM continuously tests the pool’s sanitization and pH levels allowing the OmniLogic to automatically generate the correct amount of chlorine and dispense the proper amount of pH reducer. Together, they provide an automated system controlling both sanitization and pH balance. Refer to the HL-CHEM’s owner’s manual for detailed pH dispense wiring instructions.
Low Voltage Wiring
Valve Actuators
The OmniLogic HLBASE can control up to four automatic valve actuators. When used with the optional Input/Output Expander Board (HLIOEXPAND), up to 8 valve actuators can be used. Two of the valve outputs are dedicated to the pool/spa suction (Valve2) and return (Valve1) valves. Valve3 and Valve4 is for general purpose use (solar, water feature, in-floor cleaner, etc.). All of the valve outputs on the HLIOEXPAND are for general purpose use.
For installations with solar heating, Hayward offers the AQ-SOL-KIT-xx solar kit that contains a valve, actuator, and extra temperature sensor. The “xx” indicates the valve type from the 2 choices below:
-1P
-2P
1.5” Positive Seal
2” Positive Seal
The OmniLogic is compatible with standard valve actuators manufactured by Hayward, Pentair/Compool, and Jandy. Actuators will connect to the VLV outputs on the Main Board. Refer to the diagram on page 15 for the location of valve connectors (VLV) on the OmniLogic Main Board. Record all connections in the
Connection Table on page 15.
17
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Heater Control
The HLBASE OmniLogic provides a set of 4 low voltage dry contacts that can be connected to most gas heaters or heat pumps with 24V control circuits. When used with the optional Input/Output Expander Board (HLIOEXPAND), 8 dry contact relays are available. Refer to the diagram below for a generic heater connection. The manuals supplied with most heaters also include specific wiring instructions for connecting the heater to an external control (usually identified as
“2-wire” remote control). For millivolt or line voltage heaters, contact Hayward Tech support, 908-355-7995. Refer to the information on the following pages for more details on the connection to several popular heaters. Refer to the diagram on page 15 for the location of heater connections (LVR) on the OmniLogic
Main Board. Record all connections in the Connection Table.
Generic Heaters
1. Wire heater to 120/240V power source per the instructions in the heater manual. The OmniLogic does NOT control the power going to the heater.
2. Wire the OmniLogic dry contact heater output per the diagram below. Many internal parts of the heater can get very hot--see the heater manufacturer’s recommendations on the minimum temperature rating for wires. If no guidance is given, use 105°C rated wire.
3. Set any ON/OFF switch on the heater to ON.
4. Set the thermostat(s) on the heater to the maximum (hottest) setting.
Laars Heaters
1. Turn power off to heater.
2. Remove factory jumper from terminal block.
3. Wire OmniLogic to the heater as shown.
4. Ensure toggle switch is in the ON position.
5. Set heater thermostats to maximum position.
18
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Hayward Heaters
Refer to the instructions in the heater manual for “2-wire Remote Thermostat” operation under “Remote Control Connections” and the diagram below:
1. Turn off power to heater.
2. Wire OmniLogic to terminals 1 & 2 (see diagram).
3. Leave jumper attached to terminals 4 & 5.
4. Move “BYPASS” dipswitch on heater circuit board to “ON” position (up).
5. Turn heater power back on.
6. Switch heater to either “Pool” or “Spa” (it doesn’t make any difference which is selected, the OmniLogic will take control).
7. Heater display should be “bO” (for “bypass On).
8. Heater will fire whenever OmniLogic requests (when OmniLogic “Heater” LED is illuminated).
Pentair/Purex/MiniMax
1. Turn power off to heater.
2. Remove factory installed jumper from the “Ext Switch” connector.
3. Wire the OmniLogic to the “Ext Switch” connector as shown below.
4. The wires to the OmniLogic must be separated from any line voltage wires. Failure to follow these instructions may cause erratic operation of the heater.
5. Set the Power (Thermostat Select) switch to either “Pool” or “Spa”.
6. Set the “Pool” and “Spa” thermostats to their maximum settings.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
19
Raypak RP2100 Pool/Spa Heater
1. Turn power off to heater.
2. Push the mode button to “spa” mode.
3. Set the temperature to the maximum.
4. Push the mode button to “OFF”.
5. Lastly, plug the prewired connector in the P7 position on the board.
IMPORTANT: The heater will display “OFF” when it is being remotely controlled by the OmniLogic. Some homeowners see the “OFF” display and, thinking this is a mistake, change the mode to “POOL” or “SPA” which then disables the remote control by the OmniLogic. To prevent this: Remove the heater touch pad connector (P5) which will disable the touchpad.
STA-RITE Heater
1. Turn power off to heater.
2. Remove upper jacket and open the control box.
3. Remove the jumper for the “fireman’s switch.
4. Wire to the OmniLogic using wire rated for 105°C minimum.
20
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Hayward Variable Speed Pump (VSP) Wiring
Hayward VSPs connect to the OmniLogic’s Low Speed Bus. Refer to your EcoStar manual for proper low voltage communication wiring between the OmniLogic and the Hayward Variable Speed Pump.
Temperature Sensors
The OmniLogic utilizes 10K ohm thermistor type sensors and provides three inputs. Three sensors (water temperature, air temperature and solar or dual equipment spa temperature) are included. If the OmniLogic is being used to control a solar heating system, the solar sensor is required. If dual equipment will be used, the dual equipment spa sensor is required. If both solar and dual equipment are desired, another temperature sensor must be purchased separately.
The sensors are provided with a 15 ft. cable. If a longer cable is required, contact the Hayward service dept. (908-355-7995) for information on suitable cable types and splices. Wire sensors as shown below. Record all connections using the table on page 15.
External Input Interlock
The External Input Interlock provides a means to turn the filter pump or other component on/off when certain conditions exists. A normally open or normally closed on/off external device must be connected to the OmniLogic as shown below. After properly configuring the OmniLogic (see Configuration Wizard in
Operation Manual), the filter pump and/or desired pool component will be forced on or off when the device is active.
Record all connections using the table on page 15.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
21
Remote Terminal
Up to 2 wired HLWALLMOUNT touchscreen remote terminals can be wired to the OmniLogic. Use 24AWG (or better) four conductor cable (typically phone cable) to connect the wired remote terminal to the OmniLogic’s High Speed Bus as shown below. Note that the screw connections on both the OmniLogic main unit and the wired remote terminal are numbered: Connect 1 to 1, 2 to 2, etc. as shown in the diagram below. Although the High Speed Bus has 5 screw terminals, screw #5 is not used. Refer to the HLWALLMOUNT manual for maximum distances and complete installation instructions.
Connect screw terminals
“1” to “1”, “2” to “2”, etc.
OmniLogic
Main Board
Remote Terminal x
4 3
2 1
4 3 2 1
Refer to HLWALLMOUNT manual for max distance
HL-CHEM ORP and pH Sensing Kit
Plug in the connector from the HL-CHEM into one of the Low Speed Bus connectors on the main PCB in the OmniLogic Control Center as shown below. Refer to the HLCHEM manual for complete installation instructions.
Connect Probe Cell cable here
22
Route cable through access hole
Route though knockout
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Flow Switch
Only applicable if the chlorinator function is enabled and/or if an optional HLCHEM will be used. The flow switch cable plugs into the flow switch connector on the OmniLogic’s Main Board as shown on page 13. Ensure that the connector catch “snaps” in order to provide a reliable connection.
TurboCell
Only applicable if the chlorinator function is enabled. The TurboCell should be plugged in AFTER the OmniLogic cover panel is installed. Refer to page 13 for the location of the connector.
HLIOEXPAND
The HLIOEXPAND is design to slide between guide rails and insert into a dedicated slot on the OmniLogic main board. At startup, the OmniLogic will discover the HLIOEXPAND and its inputs/outputs can be configured within the OmniLogic’s CONFIGURATION WIZARD. Refer to the HLIOEXPANDER manual for installation instructions.
HLRELAYBANK
Offering four additional high voltage relays, the HLRELAYBANK is a relay kit accessory designed to install next to the four on-board relays in the HLBASE. After installing the HLRELAYBANK, a wire connection must be made at the OmniLogic Main Board. At startup, the OmniLogic will detect the HLRELAYBANK and allow the user to configure the additional relays in the CONFIGURATION WIZARD. Refer to the HLRELAYBANK manual for installation instructions.
HLRELAY
The HLRELAY is a single high voltage relay designed to be mounted in the #9 and/or #10 positions near the four on-board relays. After installing the HLRELAY, a wire connection must be made at the OmniLogic Main Board. At startup, the OmniLogic will detect the HLRELAY and allow the user to configure the additional relay(s) in the CONFIGURATION WIZARD. Refer to the HLRELAY manual for installation instructions.
HLWLAN
The HLWLAN can be mounted up to 25ft away from the OmniLogic and requires an ethernet connection to the OmniLogic as well as a power connection to the
OmniLogic’s Main Board. Refer to the HLWLAN manual for detailed installation instructions.
System Startup
Before Startup
Before starting the OmniLogic for the first time, be sure that the following items have been completed:
1. Pool/spa chemicals are within the recommended levels according to the chart on page 4.
2. Pool/spa salt level is between 2700 – 3400 PPM.
3. Properly rated circuit breakers are installed in the OmniLogic subpanel.
4. All wiring is performed according to NEC and local codes.
5. The OmniLogic is properly grounded and bonded.
Configuration
Initial Configuration
When all input and pool related wiring is complete, replace and secure the deadfront. The OmniLogic can now be powered on for the first time. Apply power at the main panel and wait for the OmniLogic to completely start. This may take a full minute or two. Because this is the first time that the OmniLogic has been powered on, it will bring you directly to the initial configuration screen shown below. Touch the Configuration button in the center of the screen. On the following screen, touch the Configuration Wizard button as shown below.
1 / 2 configuration
No config found firmware upgrade config wizard system info backup config
SYSTEM configuration restore config display wired networking web server
23
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
About the Configuration Wizard
The OmniLogic uses a Configuration Wizard to assist in the configuration of the OmniLogic. The Configuration Wizard will ask you general questions relating to your pool/spa and specific questions about connected pool equipment. Because this process may take some time, do not begin to configure the OmniLogic unless you can dedicate at least 15 minutes or more. Configuring the OmniLogic requires knowledge of all of the connected pool equipment so have the Connection Table (page 15) handy while configuring the OmniLogic.
If you are asked a question and don’t know the answer, in many cases you’ll be able to skip the question and proceed. In some cases the Configuration Wizard will require an answer. Answer the question to the best of your ability and take note as you’ll be able to go back into the Configuration Wizard at a later time to make changes.
Navigation
The Configuration Wizard has been designed to be intuitive allowing most users the ability to navigate with little instruction. Below, a list of commonly used buttons are explained..
Save - Touch this button to save your selection.
Cancel - Touch this button to cancel your selection.
Advance - Touch this button to advance to the next screen.
Back - Touch this button to return to the previous screen.
Add - Touch this button to add an item
Delete - Touch this button to delete a highlighted item.
After being prompted to make a selection or answer a question, touch the Save button (if available) and then the Advance button to go to the next screen. To go back to a previous screen, touch the Back button. Many selections will require you to save by touching the Save button before allowing you to advance. If a wrong selection has been made, touch the Delete button to avoid saving. Some settings can be made by sliding a bar left or right to decrease or increase a value. You may be required to assign names to equipment. In this case, a keyboard will be displayed and you’ll be able to type the desired name. After naming the equipment, save then advance. This method is repeated throughout the Configuration Wizard.
Begin the Configuration Wizard
In the Configuration Wizard, select “New” to create a new Configuration file for the OmniLogic. Once underway, keep advancing through the Wizard. At the end of the Wizard, you’ll have the opportunity to save your settings or exit without saving.
Create a New Configuration or Edit an Existing One?
New
Edit
At the end of the Wizard, save your configuration by answering “Yes” to this screen.
Are You Finished Configuring
Your System?
Yes
No
POOL configuration
POOL configuration
If additional pool equipment is added after initial configuration, or you’d like to make a change to an existing configuration setting, re-enter the Configuration
Wizard and select “Edit”. The initial configuration settings will be retained and you’ll have an opportunity to make changes or additions. Be sure to save your configuration when exiting.
Configuration Wizard Guide
As you progress through the Configuration Wizard, refer to the following information to help answer questions and make selections.
Select a Language - The OmniLogic supports multiple languages. Select the desired language then touch the Advance button to advance.
Time and Date - Set the current date and time using a 12hr clock (AM/PM) or 24hr clock (military time). Save by touching the Save button when finished.
Zip Code - This is used to display the current weather if the OmniLogic is connected to the internet. Select the box, then input your zip code. Touch the Advance button when finished.
24
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Select Desired Units of Measure - If Standard is selected, temperatures will be displayed in Fahrenheit. If Metric is selected, temperatures will be displayed in Celsius.
Is the Internet Connected? - If an ethernet cable is connected to the home’s router/access point, or, if an HLWLAN is being used, answer Yes to this question. Otherwise, select No.
If Yes is selected:
Would you like your Network Automatically Configured? If an ethernet cable or an HLWLANis connected to the home’s router/access point, answer Yes. The OmniLogic should automatically connect to the home network. The HLWLAN will have to be configured to connect to the home network AFTER you’ve completed the Configuration Wizard. For instructions on how to do this, refer the HLWLAN manual.
How many Bodies of Water? The OmniLogic can support one or two bodies of water, typically a pool and spa. Select the number and advance. You’ll be brought to a screen where you can add, delete or edit a body of water (BOW). When initially configuring the OmniLogic, a “?” will appear in the BOW icon. You will have to configure this body of water by selecting it and then touching the Advance button. When finished configuring bodies of water, you’ll be returned to this same screen. Touch the Save button to save the BOW(s) and advance to the next section of configuration.
IMPORTANT: The following instructions are for pool configuration. When finished with the pool, you’ll follow the same instructions for the spa. When configuring the spa, you’ll have the option of using “Shared Equipment”. If Shared Equipment is enabled, the spa will use the filter pump as well as other equipment
(heater, chlorinator, etc.) that has been assigned to the pool.
Name of Pool - Selecting the box will allow you to edit the name. During initial configuration, the box will be blank. Select the box and then use the keyboard to enter the desired name of the body of water.
Size of Pool - Enter the pool size in gallons. If you’re not certain the size of your pool, refer to the chart below to help determine the pool capacity.
How Many Filter Pumps? - This question is for this BOW only. For example: If you have 2 pumps; one for the pool BOW and one for the spa BOW, you would answer “1” to this question.
If “1”or more is selected:
Name Filter Pump - Touch the box and use the keyboard to name the filter pump.
What Type - Depending on your answer, the OmniLogic will use one relay (single speed pumps), two relays (two speed pumps) or the low speed communication bus (VSP pumps) for pump control. Select the type of pump and advance.
If one speed or two speed pump is selected:
Which Relay is it Wired to? If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the pump. If a value is already shown in the box(es), advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected relays. Select the proper relay(s) from the table and touch the Save button to save. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the pump configuration.
Filter Pump Off for Valve Change? When Yes is selected, the pump will shut off for 35 seconds whenever the valve(s) change position.
Flow Monitoring Enabled? Requires use of a Hayward flow switch. This feature will help protect the filter pump from damage due to no flow. When Yes is selected, the OmniLogic will monitor the state of water flow when the filter pump is on. If no flow is detected for more than 20 minutes, the OmniLogic will shut down the pool pump and will indicate an error. The error will be cleared the next time the pump is turned on.
Freeze Protection Enabled? Freeze protection is used to protect the pool and plumbed equipment against freeze damage during
25
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
cold temperatures. If freeze protection is enabled AND the air temperature sensor falls below the freeze threshold, the OmniLogic will turn on the filter pump to circulate the water. If two BOWs are configured, the valves will also alternate between the pool and spa every
30 minutes and the filter pump will turn off while the valves are turning. The chlorinator will not operate if freeze protection is the only reason the pump is running.
If Yes is selected:
Freeze Protection Temperature? Select the temperature to be used for freeze protection. Temperature is adjustable from
33ºF-42ºF (1ºC-6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled.
If VSP is selected:
Which Hayward Unique Address? If using a VSP, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Save button. The address should now be shown in the box and you can advance to the next screen to continue the VSP configuration.
Minimum RPM / Maximum RPM - Set the minimum and maximum desired RPM. Refer to your pump manual for more information.
Minimum Allowed Pump Speed % / Maximum Allowed Pump Speed % - The OmniLogic will automatically calculate these values based on the minimum and maximum RPM that were previously entered. They can be changed as desired.
Speed Presets - Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets. These presets will be used when setting schedules for your pump.
Filter Pump Off for Valve Change? When Yes is selected, the pump will shut off for 35 seconds whenever the valve(s) change position.
Flow Monitoring Enabled? Requires use of a Hayward flow switch. This feature will help protect the filter pump from damage due to no flow. When Yes is selected, the OmniLogic will monitor the state of water flow when the filter pump is on. If no flow is detected for more than 20 minutes, the OmniLogic will shut down the pool pump and will indicate an error. The error will be cleared the next time the pump is turned on.
Freeze Protection Enabled? Freeze protection is used to protect the pool and plumbed equipment against freeze damage during cold temperatures. If freeze protection is enabled AND the air temperature sensor falls below the freeze threshold, the OmniLogic will turn on the filter pump to circulate the water. If two BOWs are configured, the valves will also alternate between the pool and spa every
30 minutes and the filter pump will turn off while the valves are turning. The chlorinator will not operate if freeze protection is the only reason the pump is running.
If Yes is selected:
Freeze Protection Temperature? Select the temperature to be used for freeze protection. Temperature is adjustable from
33ºF-42ºF (1ºC-6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled.
Freeze Protection Speed? This is the speed of the pump while freeze protection is active. Select the desired pump speed
%.
How many Heaters? This question is for THIS BOW ONLY. For example: If you have 2 heaters, one for the pool BOW and one for the spa BOW, you would answer “1” to this question.
If “1”or more is selected:
Heater Cooldown Enabled? This feature ensures that the heater cools down before water circulation is stopped. When enabled, the Omni-
Logic will continue to run the filter pump for 5 minutes after the heater turns off.
Heater Extend Enabled? If “Enabled”, the filter extend logic keeps the filter pump running beyond the normal turn-off time until the pool (or spa) is heated up to the desired temperature setting. Heater extend will NOT cause the filter pump to turn on, it will only delay the turn off time when the heater is operating.
Maximum Settable Temperature? This is the maximum allowed setting for the heater regardless of its default range. There may be circumstances where you will want to limit the high temperature of your heater to a temperature that is lower than the factory high setting.
Select and Configure a Heater At this screen, you can add, delete and configure your heater(s). Select the desired heater, then touch the
Advance button. When finished configuring heater(s), you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring heater(s):
What Type? Heater choices are Solar, Heat Pump and Gas. Make your selection and advance.
If Gas Heater is selected:
Name Heater Select the box, then type the desired name for your heater. This name will be used when referring to this particular
26
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
heater.
Which Relay is it Wired to? Selecting the box will bring you to a table showing all detected relays. Select the low voltage relay that is wired to the heater (refer to the Connection Table for this information), then advance. The relay should now be shown in the box.
Advance to the next screen to continue gas heater configuration.
If more than one heater has been configured for this BOW:
Heater Priority Level? Because more than one heater is configured to heat this BOW, you can set the Priority for which heater you’d like to use first (selection “1”). If the priority heater can’t meet the demand, the next heater will start (selection
“2”).
Heater Priority Duration? Set the amount of time that you will allow the priority heater (“1”) to heat before allowing the next heater to start. If the priority heater meets the demand within this time frame, the next heater will not be used.
Minimum Operation Speed? For variable speed pumps, select the lowest pump speed that is allowed while heating. Set a speed that will ensure that there will be sufficient flow for the heater to operate properly.
If Heat Pump is selected:
Name Heater Select the box, then type the desired name for your heater. This name will be used when referring to this particular heater.
Which Relay is it Wired to? Selecting the box will bring you to a table showing all detected relays. Select the low voltage relay that is wired to the heater (refer to the Connection Table for this information), then advance. The relay should now be shown in the box.
Advance to the next screen to continue heat pump configuration.
Minimum Allowed Air Temperature for Heater? If the air temperature falls below this setting, the heater will be prevented from running, regardless of conditions. This feature is especially useful for heat pumps which become less efficient as the outdoor ambient temperature falls.
If more than one heater has been configured for this BOW:
Heater Priority Level? Because more than one heater is configured to heat this BOW, you can set the Priority for which heater you’d like to use first (selection “1”). If the priority heater can’t meet the demand, the next heater will start (selection
“2”).
Heater Priority Duration? Set the amount of time that you will allow the priority heater (“1”) to heat before allowing the next heater to start. If the priority heater meets the demand within this time frame, the next heater will not be used.
Minimum Operation Speed? For variable speed pumps, select the lowest pump speed that is allowed while heating. Set a speed that will ensure that there will be sufficient flow for the heater to operate properly.
If Solar is selected:
Name Heater Select the box, then type the desired name for your heater. This name will be used when referring to this particular heater.
Does the Solar Heater Have a Pump? Select whether the solar heating system has a dedicated recirculation pump. If so, the
OmniLogic will turn this pump on when the pool temperature is below the heater setting and there is solar heat available.
If Yes is selected:
Which Relay is it Wired to? Selecting the box will bring you to a table showing all detected relays. Select the high voltage relay that is wired to the heater (refer to the Connection Table in for this information), then advance. The relay should now be shown in the box. Advance to the next screen to continue solar heater configuration.
Does the Solar Heater Have a Valve? Select whether the solar heating system has a diverter valve to route pool/spa water through the solar collectors. If so, the OmniLogic will rotate this valve when the pool temperature is below the heater setting and there is solar heat available.
If Yes is selected:
Which Relay is it Wired to? Selecting the box will bring you to a table showing all detected low voltage relays. Select the relay that is wired to the solar valve, then advance. The relay should now be shown in the box. Advance to the next screen to continue solar heater configuration.
Where is the Solar Temperature Sensor Located? Selecting the box will bring you to a table showing all detected sensors. Select the solar sensor (usually SENS3), then advance. The sensor should now be shown in the box. Advance to the next screen to continue solar heater configuration.
27
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
If more than one heater has been configured for this BOW:
Heater Priority Level? Because more than one heater is configured to heat this BOW, you can set the Priority for which heater you’d like to use first (selection “1”). If the priority heater can’t meet the demand, the next heater will start (selection
“2”).
Heater Priority Duration? Set the amount of time that you will allow the priority heater (“1”) to heat before allowing the next heater to start. If the priority heater meets the demand within this time frame, the next heater will not be used.
Minimum Operation Speed? Select the lowest pump speed that is allowed while solar heating. Set a speed that will ensure that there will be sufficient flow for the solar heating system to operate properly.
Do you a have Sense & Dispense Module? Select Yes if a Hayward HLCHEM (sold separately) is connected to the OmniLogic.
If Yes is selected:
The next few screens will configure the OmniLogic to use Sense and Dispense. The OmniLogic automatically detects smart components like the
HLCHEM, and assigns a Hayward Unique Address. If multiple components are detected, the OmniLogic will show a table of devices and prompt you to select the proper device.
Which Hayward Unique Address? If a Hayward Unique Address (HUA) is already shown in the box, touch the Advance button. If no address is shown, selecting the box will bring you to a table showing all detected Sense and Dispense devices. Select the HLCHEM from the table and touch the Save button to save. The address should now be shown. Touch the Advance button to continue configuring the OmniLogic for use with the HLCHEM.
Does ORP Control Chlorination? If you say Yes to this, the HLCHEM will constantly measure ORP and will increase or decrease chlorine generation based on a predetermined setpoint that you will select. The system will monitor ORP and automatically generate the correct amount of chlorine to maintain a desired level. Alternatively, if you say No to this question, the HLCHEM will monitor ORP, but the amount of chlorine generated will be based on a manual setting that you will select.
If Yes is selected:
ORP Setpoint - Set the desired ORP level which is measured in mV. 650mV is the default. The OmniLogic will continuously measure
ORP and generate the proper amount of chlorine to maintain this setpoint.
ORP Timeout - Select a timeout interval. If the OmniLogic has been chlorinating for more than the selected ORP timeout without reaching the desired level, the chlorinator will turn off and display an alarm. The user must clear the alarm to resume chlorination.
Type of Cell? Select the type of Hayward TurboCell that is installed in your system.
Where is the Cell Located? If a Hayward Unique Address (HUA) is already shown in the box, touch the Advance button. If no address is shown, selecting the box will bring you to a table showing all detected devices. Select the TurboCell and save.
If No is selected:
Do You Have a Salt Water Chlorine Generator? (requires Hayward Turbo Cell)
If Yes is selected:
Type of Cell? Select the type of Hayward TurboCell that is installed in your system.
Where is the Cell Located? If an entry is already shown in the box, touch the Advance button. If no entry is shown, selecting the box will bring you to a table showing the detected cell. Select the TurboCell and save.
Percentage of Output - The OmniLogic can only generate chlorine while the filter pump is operating. Set the percentage of run time that you desire chlorine generation. Raise this value to generate more chlorine. Lower this value to generate less.
Is pH Reduction Enabled? Select Yes if you have a dispenser to lower pH connected to the OmniLogic.
If Yes is selected:
Are you Using Acid or CO2? Select one.
Which relay is it Wired to? Select the box to advance to the High Voltage Table. This table lists all of the high voltage relays that are installed in the OmniLogic. Select the relay that is wired to the pH dispense unit. Refer to the Connection Table for this information.
pH Setpoint - Selecting the box will allow you to change the setpoint (7.5 default). Touch the Advance button when finished.
pH Dispensing Timeout - Select a timeout interval. If the unit has been dispensing for more than the selected timeout without reaching the desired level, pH dispensing will turn off and an alarm will be displayed. Check the chemical supply and the feeder. If both are
OK, the timeout may need to be increased. The user must clear the alarm to resume pH dispensing.
28
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
pH Extend Enabled - If enabled, the OmniLogic will continue to run the filter pump regardless of schedule until the pH level in the pool has reached the setpoint.
Do You Have a Salt Water Chlorine Generator? (requires Hayward Turbo Cell)
If Yes is selected:
Type of Cell? Select the type of Hayward TurboCell that is installed in your system.
Where is the Cell Located? If an entry is already shown in the box, touch the Advance button. If no entry is shown, selecting the box will bring you to a table showing the detected cell. Select the TurboCell and save.
Percentage of Output - The OmniLogic can only generate chlorine while the filter pump is operating. Set the percentage of run time that you desire chlorine generation. Raise this value to generate more chlorine. Lower this value to generate less.
How Many Cleaners? - This question is for THIS BOW ONLY. For example: If you have 2 cleaners; one for the pool BOW and one for the spa BOW, you would answer “1” to this question.
If “1”or more is selected:
Select and Configure a Cleaner At this screen you can add, delete and configure your cleaner(s). Select the desired cleaner, then touch the
Advance button. When finished configuring cleaner(s), you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring cleaner(s):
Type of Cleaner? Touch the box and select the type of cleaner used. Choices are Pressure, Suction, Robotic and In-Floor.
Name of Cleaner - Touch the box and use the keyboard to name the cleaner.
Does Cleaner Have a Pump? Select whether the cleaner has a dedicated pump. If so, the OmniLogic will turn this pump on when the cleaner is scheduled to run.
If Yes is selected:
What Type? Select the type of pump used. The choices are Single Speed, Two Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to? If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the pump. If a value is already shown in the box(es), advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected relays. Select the proper relay(s) from the table and touch the Save button to save. The relay should now be shown in the box(es) and you can advance to the next screen to continue the pump configuration.
If VSP is selected:
Which Hayward Unique Address? If using a VSP for your cleaner pump, you’ll be asked what is the Hayward Unique
Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Save button. The address should now be shown in the box and you can advance to the next screen to continue the VSP configuration.
Minimum RPM / Maximum RPM - Set the minimum and maximum desired RPM. Refer to your pump manual for more information.
Minimum Allowed Pump Speed % / Maximum Allowed Pump Speed % - The OmniLogic will automatically calculate these values based on the minimum and maximum RPM that were previously entered. They can be changed is desired.
Speed Presets - Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets. These presets will be used when setting schedules for your pump.
Does Cleaner have a Valve? Select whether the cleaner requires a valve to change position when in use.
If Yes is selected:
How Many? Select how many valves are used for the cleaner.
Where is the Valve(s) Wired? Selecting the box will bring you to a table showing all detected low voltage relays. Select the relay(s) that is wired to the cleaner valve(s), then advance. The valve(s) should now be shown in the box(es). Advance to the next screen to continue cleaner configuration.
Would you like your valve(s) to cycle On and Off at a set interval? If you would like the cleaner valve(s) to cycle to a set interval
29
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
while cleaning, select Yes. Set the interval on the next screen.
Freeze Protection Enabled? Freeze protection is used to protect the pool and plumbed equipment against freeze damage during cold temperatures. If freeze protection is enabled AND the air temperature sensor falls below the freeze threshold (refer to pump configuration), the OmniLogic will turn on the cleaner pump to circulate the water.
How Many Water Feature? - This question is for THIS BOW ONLY. For example: If you have 2 water features; one for the pool BOW and one for the spa
BOW, you would answer “1” to this question.
If “1”or more is selected:
Select and Configure a Water Features At this screen you can add, delete and configure your water features. Select the desired water feature, then touch the Advance button. When finished configuring water features, you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring water features:
Type of Water Feature? Touch the box and select the type of water feature used. Choices are Water Feature, Water Slide, Waterfall, and
Fountain.
Name of Water Feature - Touch the box and use the keyboard to name the water feature.
Does Water feature Have a Pump? Select whether the water feature has a dedicated pump. If so, the OmniLogic will turn this pump on when the water feature is scheduled to run.
If Yes is selected:
What Type? Select the type of pump used. The choices are Single Speed, Two Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to? If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the pump. If a value is already shown in the box(es), advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected relays. Select the proper relay(s) from the table and touch the Save button to save. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the pump configuration.
If VSP is selected:
Which Hayward Unique Address? If using a VSP for your water feature pump, you’ll be asked what is the Hayward
Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Save button.
The address should now be shown in the box and you can advance to the next screen to continue the VSP configuration.
Minimum RPM / Maximum RPM - Set the minimum and maximum desired RPM. Refer to your pump manual for more information.
Minimum Allowed Pump Speed % / Maximum Allowed Pump Speed % - The OmniLogic will automatically calculate these values based on the minimum and maximum RPM that were previously entered. They can be changed is desired.
Speed Presets - Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets. These presets will be used when setting schedules for your pump.
Does Water Feature have a Valve? Select whether the water feature requires a valve to change position when in use.
If Yes is selected:
How Many? Select how many valves are used for the water feature.
Where is the Valve(s) Wired? Selecting the box will bring you to a table showing all detected low voltage relays. Select the relay(s) that is wired to the water feature valve(s), then advance. The valve(s) should now be shown in the box. Advance to the next screen to continue water feature configuration.
Would you like your valve(s) to cycle On and Off at a set interval? If you would like the water feature valve(s) to cycle to a set interval while cleaning, select Yes. Set the interval on the next screen.
Freeze Protection Enabled? Freeze protection is used to protect the pool and plumbed equipment against freeze damage during cold temperatures. If freeze protection is enabled AND the air temperature sensor falls below the freeze threshold (refer to pump configuration), the OmniLogic will turn on the water feature pump to circulate the water.
Do you have ColorLogic Lights? Select yes if you are using any type of Hayward ColorLogic pool or spa lights. Note that the OmniLogic can only support
30
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
ColorLogic lights in Standalone mode using its high voltage relays. Controlling the lights requires power cycling so although more than one set of ColorLogic lights can be wired to the same relay, do not connect any other device to relays that are controlling ColorLogic lights.
If Yes is selected:
What Kind of Lights? Touch the box to select the type of ColorLogic lights that will be used. Selections are Universal ColorLogic (UCL), Color-
Logic 4.0 (CL 4.0) and ColorLogic 2.5 (CL 2.5).
Name the Group of Lights - Touch the box and use the keyboard to name the ColorLogic lights.
How Many Relays are Lights Wired to? Select the number of relays used by the ColorLogic lights.
Which Relay is it Wired to? Touching the box(es) will bring you to a table showing all detected relays. Select the relay(s) that are connected to the ColorLogic lights and touch the Save button to save. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the ColorLogic configuration.
Do you have any other Lights? Select yes if the OmniLogic will be controlling other types of pool, spa or outdoor/landscape lighting.
If Yes is selected:
How Many Relays are Lights Wired to? Select the number of relays used by the ColorLogic lights.
Select and Configure Lights At this screen you can add, delete and configure your additional lights. Select the desired light, then touch the
Advance button. When finished configuring lights, you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring water features:
What Kind of Lights? Touch the box to select either incandescent or other.
Name the Group of Lights - Touch the box and use the keyboard to name the ColorLogic lights.
Which Relay is it Wired to? Touching the box(es) will bring you to a table showing all detected relays. Select the relay(s) that are connected to the lights and touch the Save button to save. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the ColorLogic configuration.
How Many Accessories? Select the number of accessories that will be used for this BOW only. You’ll have an opportunity to configure accessories for the spa and also the backyard at a later point.
If “1”or more is selected:
Select and Configure Accessories At this screen you can add, delete and configure your accessories. Select the desired accessory, then touch the Advance button. When finished configuring accessories, you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring accessories:
Type of Accessory? Touch the box and select the type of accessory used. Choices are Laminars, Jets, Blower and Other.
Name of Accessory - Touch the box and use the keyboard to name the accessory.
Does Accessory Have a Pump? Select whether the accessory has a dedicated pump. If so, the OmniLogic will turn this pump on when the accessory is scheduled to run.
If Yes is selected:
What Type? Select the type of pump used. The choices are Single Speed, Two Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to? If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the pump. If a value is already shown in the box(es), advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected relays. Select the proper relay(s) from the table and touch the Save button to save. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the pump configuration.
If VSP is selected:
Which Hayward Unique Address? If using a VSP for your accessory pump, you’ll be asked what is the Hayward Unique
Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Save button. The address should now be shown in the box and you can advance to the next screen to continue the VSP configuration.
Minimum RPM / Maximum RPM - Set the minimum and maximum desired RPM. Refer to your pump manual for more
31
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
information.
Minimum Allowed Pump Speed % / Maximum Allowed Pump Speed % - The OmniLogic will automatically calculate these values based on the minimum and maximum RPM that were previously entered. They can be changed as desired.
Speed Presets - Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets. These presets will be used when setting schedules for your pump.
Accessory Wired to Relay? Select whether the accessory requires the use of a high voltage relay.
If Yes is selected:
Select Relay - Touching the box will bring you to a table showing all detected relays. Select the relay that is connected to the accessory and touch the Save button to save. The relay should now be shown in the box and you can advance to the next screen to continue the accessory configuration.
Does Accessory have a Valve? Select whether the accessory requires a valve to change position when in use.
If Yes is selected:
How Many? Select how many valves are used for the accessory.
Where is the Valve(s) Wired? Selecting the box will bring you to a table showing all detected low voltage relays. Select the relay(s) that is wired to the accessory valve(s), then advance. The valve(s) should now be shown in the box. Advance to the next screen to continue accessory configuration.
Would you like your valve(s) to cycle On and Off at a set interval? If you would like the accessory valve(s) to cycle to a set interval while cleaning, select Yes. Set the interval on the next screen.
Freeze Protection Enabled? Freeze protection is used to protect the pool and plumbed equipment against freeze damage during cold temperatures. If freeze protection is enabled AND the air temperature sensor falls below the freeze threshold (refer to pump configuration), the OmniLogic will turn on the accessory pump to circulate the water.
NOTE: The remaining configuration settings are not specific to a BOW.
Do You Have an Air Temperature Sensor? Select whether there is an air temperature sensor wired to the OmniLogic.
If Yes is selected:
Where is the Sensor Wired?
Touching the box will bring you to a table showing all detected sensors connections. Select the sensor connection used for the air sensor (typically SENS2) and touch the Save button to save. The sensor connection should now be shown in the box and you can advance to the next screen to continue configuration.
Do You Have a Pool Temperature Sensor? Select whether there is a pool temperature sensor wired to the OmniLogic.
If Yes is selected:
Where is the Sensor Wired?
Touching the box will bring you to a table showing all detected sensors connections. Select the sensor connection used for the pool sensor
(typically SENS1) and touch the Save button to save. The sensor connection should now be shown in the box and you can advance to the next screen to continue configuration.
Do You Have a Flow Switch? Select whether there is a flow switch wired to the OmniLogic.
If Yes is selected:
Where is the Sensor Wired?
Touching the box will bring you to a table showing all detected sensors connections. Select the sensor connection used for the flow switch (typically FLOW SWITCH 1) and touch the Save button to save. The sensor connection should now be shown in the box and you can advance to the next screen to continue configuration.
Do You Have an External Interlock Sensor? Select whether there is an external interlock sensor wired to the OmniLogic. To learn more about interlocks, refer to the interlock section on the following page.
If Yes is selected:
Where is the Sensor Wired?
Touching the box will bring you to a table showing all detected sensors connections. Select the sensor connection used for the external interlock switch (typically ExtSensor) and touch the Save button to save. The sensor connection should now be shown in the box and you can advance to the next screen to continue configuration.
Select and Configure Sensors At this screen you can add, delete and configure your sensors. Select the desired sensor, then touch the Advance
32
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
button. When finished configuring sensors, you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring sensors:
Where is the Sensor Located? Touch the box and go to the table showing the BOWs and the Backyard. Select the location where the sensor is installed.
What Type of Sensor? Select the type of sensor. Choices are Air, Water, Flow or Solar.
Name Sensor - Touch the box and use the keyboard to name the sensor.
Where is the Sensor Wired? Touching the box will bring you to a table showing all detected sensors connections. Select the sensor connection used for the sensor and touch the Save button to save. The sensor connection should now be shown in the box and you can advance to the next screen to continue configuration.
How Many Accessories are in the Backyard? Select the number of accessories that will be used for the backyard.
If “1”or more is selected:
Select and Configure Accessories At this screen you can add, delete and configure your accessories. Select the desired accessory, then touch the Advance button. When finished configuring accessories, you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring accessories:
Type of Accessory? Touch the box and select the type of accessory used. Choices are Light and Accessory.
Name of Accessory - Touch the box and use the keyboard to name the accessory.
Which Relay is it Wired to? - Touching the box will bring you to a table showing all detected relays. Select the relay that is connected to the accessory and touch the Save button to save. The relay should now be shown in the box and you can advance to the next screen to continue the accessory configuration.
Would You Like to Add an Interlock? An interlock will allow the OmniLogic to turn on or to turn off a piece of pool equipment (slave) based on the state of other pool equipment (master). An example of this is would be the desire to turn on walkway lighting (slave) every time the pool deck lights (master) are turned on. This equipment could have been wired together to accomplish the same function, but by interlocking the walkway lights to the deck lights, you’ll maintain the ability to turn on the walkway lights independently.
An interlock can also control pool equipment based on the state of a temperature sensor or normally on/off switch. An example of this would be to turn on a cabana fan (slave) whenever the outside temperature sensor (master) reads above 90ºF. Or, turning on a bug lamp (slave) when a photo sensor (master) detects that it is dusk.
If Yes is selected:
Select and Configure Interlocks At this screen you can add, delete and configure interlocks. Select the desired interlock, then touch the Advance button. When finished configuring interlocks, you’ll be returned to this same screen. Touch the Save button to save all your settings and advance to the next section of configuration. Refer to the following information when configuring interlocks:
Select Equipment Type You Would Like to Interlock This selection is the pool equipment (slave) that will be turned on or off based on the state of the external input device (master) or other pool equipment (master). Choices are Heater, Filter and Feature.
If Heater is selected:
Select Body of Water’s Heater Group you Wish to Interlock - Touch the box and select the BOW that the heater is attached to.
If Filter is selected:
Select Body of Water’s Filter you Wish to Interlock - Touch the box and select the BOW that the filter pump is attached to.
If Feature is selected:
Select a Feature you Wish to Interlock - Touching the box will display all the pool equipment that has been configured as a feature.
Select the desired feature. This will be the slave feature and will be controlled by either an external input or a master feature.
What State is Feature in When Interlock becomes Active - Select whether you want to turn the interlocked feature (slave) on or off when the external input device becomes active or the pool equipment (master) turns on/off.
Select Equipment Type you Would Like to Interlock to - The interlocked feature will turn on/off based on the master device that is selected here. Choices are Sensor (temperature or switch), Filter pump or Feature.
33
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
If Sensor is selected:
Select Sensor You Would Like to Interlock to - Touch the box and select a sensor from the list shown. The list will contain all sensors that have been previously configured. The interlocked feature will turn on/off based on the state of this sensor.
If a temperature sensor is selected:
Set Temperature/Set State - Here you’ll be able to set a temperature (setpoint) and have the interlocked feature turn on or off if the temperature goes higher or lower than the setpoint. Select the desired temperature and the state
(“Above” if you want the interlocked feature to turn on/off if temperature rises above setpoint; “Below” if you want interlocked feature to turn on/off if temperature falls below setpoint).
If an external interlock sensor is selected:
Interlock is Active When Sensor is: - Select either High or Low. For normally open switches, select High. For normally closed switches, select Low.
The OmniLogic will summarize the interlock logic. If the statement is true, select Yes. If not, select No and edit the interlock.
If Filter is selected:
Select Body of Water’s Filter you Wish to Interlock to - Touch the box and select the BOW that the filter pump (master) is attached to.
Interlock is Active When Filter is: - Select the state of the filter that will activate the interlocked feature.
The OmniLogic will summarize the interlock logic. If the statement is true, select Yes. If not, select No and edit the interlock.
If Feature is selected:
Select a Feature - All pool equipment that has been configured as a feature, will be listed. This selection will be the master feature that will control the slave interlocked feature.
Interlock is Active When Feature is: - This question relates to the master feature. Select the state of the master feature that will activate the interlocked feature.
The OmniLogic will summarize the interlock logic. If the statement is true, select Yes. If not, select No and edit the interlock.
34
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
LIMITED WARRANTY (effective 03/01/12) Hayward warrants its Pro Logic, OnCommand and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years. Hayward also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year. These warranties are applicable from the initial date of purchase on private residential swimming pools in the US and Canada. Installations of product for use on commercial pools in the US and Canada is covered for a period of one (1) year for defects in materials and workmanship. Hayward warrants all accessories and replacement parts for the above-identified pool automation and chlorination products for a period of one (1) year. Accessories also include remotes, actuators, base stations, temperature sensors, flow switches and chemistry probes. Each of these warranties is not transferable and applies only to the original owner.
Hayward shall not be responsible for cartage, removal, repair or installation labor or any other such costs incurred in obtaining warranty replacements or repair.
Proof of purchase is required for warranty service. If written proof of purchase is not provided, the manufacturing date code will be the sole determinant of the date of installation of the product. To obtain warranty service or repair, please contact the place of purchase or the nearest Hayward authorized warranty service center. For more information on authorized service centers please contact the
Hayward Technical Service Support Center (61 Whitecap Road, North Kingstown RI, 02852) or visit the
Hayward web site at www.hayward.com.
WARRANTY EXCLUSIONS:
1. Material supplied or workmanship performed by others in process of installation.
2. Damage resulting from improper installation including installation on pools larger than the product rating.
3. Problems resulting from failure to install, operate or maintain the product(s) in accordance with the recommendations contained in the owners manual(s).
4. Problems resulting from failure to maintain pool water chemistry in accordance with the recommendations in the owners manual(s).
5. Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or alternations, fire, flood, lightning, freezing, external water, degradation of natural stone used in or immediately adjacent to a pool or spa, war or acts of God.
6. Use of a non-genuine Hayward replacement salt chlorination cell on any Hayward automation or chlorination product will void the warranty for that product.
The express limited warranty above constitutes the entire warranty of Hayward Pool Products with respect to its products and is in lieu of all other warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose. In no event shall Hayward Pool products be responsible for any consequential, special or incidental damages of any nature. Some states do not allow a limitation on how long an implied warranty lasts, or the exclusion of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
35
36
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
37
38
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
39
FOR FURTHER INFORMATION OR CONSUMER
TECHNICAL SUPPORT, VISIT OUR WEBSITE AT
www.hayward.com
40
Hayward is a registered trademark and OmniLogic, AquaRite and Sense &
Dispense are trademarks of Hayward Industries, Inc. © 2013 Hayward Industries, Inc.
All other trademarks not owned by Hayward are the property of their respective owners.
Hayward is not in any way affiliated with or endorsed by those third parties.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- - Before You Begin
- - Overview
- 2 Preparing Pool/Spa Water
- 4 Mounting Equipment
- 7 Plumbing
- 11 Wiring
- 21 System Startup
- 22 Configuration Wizard
- 7 Installation Steps
- 8 General Water Chemistry
- 9 Pool/Spa Water Salt
- 10 OmniLogic Enclosure
- 11 Temperature Sensors
- 12 Optional Chlorination
- 12 Optional HL-CHEM Sensing Kit
- 12 Optional AQL-CHEM2 pH Dispensing
- 12 Optional HLWALLMOUNT
- 12 Optional HLWLAN
- 12 Optional Valve Actuators
- 13 Pool/Spa Configuration
- 16 TurboCell
- 16 Flow Switch
- 18 Main Service
- 18 Grounding and Bonding
- 18 Circuit Breaker Installation and Wiring
- 18 General Purpose Outlet
- 18 OmniLogic Power
- 21 Low Voltage Wiring
- 27 Before Startup
- 28 Startup and Configuration Wizard
- 29 Bodies of Water
- 29 Filter Pumps
- 32 HL-CHEM
- 33 Chlorinator
- 33 Cleaners
- 34 Water Features
- 35 ColorLogic Lights
- 35 Accessories
- 36 Sensors
- 37 Interlocks
- 39 OmniLogic Limited Warranty