Hard Wired Controls - 24V Output FH-WC 24

Add to my manuals
1 Pages

advertisement

Hard Wired Controls - 24V Output FH-WC 24 | Manualzz

Hard Wired Controls - 24V Output

FH-WC 24

80

• Incorporates separate boiler and pump interlocks

• Convenient and easy to wire floor heating connection box

The central component in the FH-WC 24 hard wired control range is the wiring centre ideal for use in water based floor heating systems.

FH-WC is a connection box for use in hydronic floor heating systems supplied from a manifold.

FH-WC is a wiring centre for connecting up to

10 thermal actuators to the room thermostats.

It is provided with two potential-free relays for controlling a circulation pump and a boiler. The relays are activated when one or more thermostats require heat.

FH-WC is connected to 230 VAC/50 Hz.

Mounting is made easy due to the symbols printed on the screw terminals.

FH-WT 24 dial setting room thermostat used for single room temperature control and temperature setting can be maximum and/or minimum limited. A LED light behind the front cover indicates heat demand.

FH-WS is a room thermostat with manual night set-back and optional connection for a floor sensor. If a floor sensor is connected min. or max. regulation is selected with a switch depending on the type of floor i.e. wooden floor (max.) or tiles (min.). The thermostat is provided with thermal feedback to improve accuracy. LED behind front cover indicates heat demand.

Temperature range is 6 - 30°C.

FH-WP is a tamper proof model of the FH-WS for use in public environments i.e. schools. The thermostat is used for single room temperature control. The thermostat is provided with thermal feedback to improve accuracy. LED behind front cover indicates heat demand. Temperature range is 6 - 30°C.

Additional Information:

Wiring information .......................................................p. 96

Hard-wired Systems Wiring Box - FH-WC 24

Code No

Number of zones

(thermostats in/thermal actuator zones out)

Time channels

(requires external 1-channel or 2-channel time control)

Boiler interlock relay, (voltage free)

Pump interlock relay, (voltage free)

Supply voltage

(2)

(2)

088H001701

2

8

(1)

SPST, 6(2)A

SPST, 6(2)A

24 Vac, +/- 15%, 50/60 Hz

Output voltage

(to zone thermostats and thermal actuators)

Output per channel

24 Vac up to 0.5A

Dimensions (mm) 314 wide x 110 high x 61 deep

Notes:

(1) One of two time channels can be assigned at time of installation to each thermostat.

(2) Boiler and pump relays are activated whenever one or more zone thermostats call for heat.

Wired Controls, 24V Output

FH-WT, Dial setting room thermostat with setback

FH-WS, Dial setting room thermostat with manual night setback and optional connection for a floor sensor

FH-WP, Tamperproof room thermostat

FH-WF, Floor sensor for FH-WS room thermostat, 30 kohm, 20°C, cable length 3m

Code No.

088H002200

008H002400

088H002300

008H002500

Underfloor Heating Controls

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement