ROOM AIR CONDITIONING

ROOM AIR CONDITIONING
ECONAVI with Intelligent Eco Sensors
Panasonic has employed ECONAVI (Human Detection Technology) on its air conditioner in 2007 and perfected the feature since its launch.
Panasonic is now introducing ECONAVI air conditioner to the US market.
ECONAVI sensors to moderate the temperature. This smart technology monitors and senses when there are people in the room and determine
how much activity is occurring, then automatically adjusts the temperature setting accordingly for optimum operation.
The area search mode uses sensors that can detect activity in the room and direct cooling to the occupied area.
The low activity detection mode monitors the room, decreasing cooling when there is less movement, while the absence detection feature switches
to a slightly less powerful cooling mode when there is no one in the room at all.
Absence Detection
Area Search
Activity Detection
ECONAVI detects human absence in the room
and raise the target temperature
ECONAVI detects changes in human movements
and direct the cooling to the occupied area to
avoid the cooling in unoccupied area of the room.
ECONAVI detects changes in activity levels and
reduce the cooling power by adjusting set
temperature.
DETECT
CONTROL
No one is in the room.
Detects absence.
DETECT
Gradually modulates
cooling power by setting
the new target temperature
(set temp +4˚F)
Only one person in
the room.
CONTROL
DETECT
CONTROL
Reduces the loss of
cooling in the unoccupied
area of the room.
Level of activity is
decreased. Detects low
activity.
Reduces cooling power by
setting new target
temperature
(set temp +2˚F)
ECONAVI in cooling mode: *The target temperature set by ECONAVI will be restored automatically to the set temperature when the new condition is detected.
Area Search
Directs airflow to wherever
you are in the room.
Activity Detection
Adjusts cooling and
heating power to your
activities.
Absence Detection
Quality
Management
System
Certificate
Human
Activity Sensor
Reduces cooling and heating
power when you are not in the
room.
Use of the AHRI Certified™ mark indicates
a manufacture's participation in the
certification program.
For verification of certification for individual
products, go to www.ahridirectory.org
Certified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-AR 1010
Certified to ISO 9001: 2008
Cert. No.: MY-AR 1010
Environmental
Management
System
Certificate
Certified to ISO 14001: 2004
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-ER 0112
Certified to ISO 14001: 2004
Cert. No.: MY-ER 0112
Panasonic Corporation of North America
Air Conditioning Group
1690 Roberts Blvd., NW, Suite 110, Kennesaw, GA 30144
WWW.PANASONIC.COM/AIRCON
HOW DOES ECONAVI HUMAN ACTIVITY WORK?
Present
Enter Room
1
Serving the US Ductless
market since 1983
Low activity
ROOM AIR CONDITIONING
Absent
High activity
3
2
EXTERIOS
Normal activity
Exit Room
Out
5
4
+4°F
Set Temperature
20min.
+4°F
20min.
+2°F
-4°F
-2°F
-4°F
Fan Speed
Set Speed
Legend:
Set Temperature
Cooling Power
Set Speed
Heating Power
Because its products are subject to continuous improvements, Panasonic reserves the right to modify product design and specifications without notice and without incurring any obligations.
©Copyright 2012, Panasonic Air Conditioning Products.
1 Hour
Max Medium Fan
Set Speed
Remark: Set temperature on remote control display remains unchanged.
Caution Related to Safety
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
MAY 2013
May 2013
Features
Panasonic Adding New Air Conditioner Lineup-Setting Another Mile Stone in the US
Ductless Split History
ECONAVI
ECONAVI features intelligent Human Activity
Sensor and new technologies that can detect
human activity and absence, and optimize air
conditioner operation according to room
conditions.
Room Freeze Protection
Room Freeze Protection mode helps prevent
plumbing damage due to sub-Freezing
Temperature. This mode automatically turns on
the compressor for Heat pump operation if the
room temperature falls to about 4°F.
Room Freeze Protection
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
SEER
28.5
LOW
AMBIENT
OPERATION
Wireless Remote Controller
No.1* High Energy Efficiency*
XE9PKUA
Unit Model No.
Powerful Heating at Low Ambient
Heating is still possible even if the temperature drops as low as 0 ˚F for reliable heating in the
middle of the harshest winter.
Indoor Unit
Outdoor Unit
CS-XE9PKUA
CU-XE9PKUA
CS-XE12PKUA
CU-XE12PKUA
Btu/h
8,700(2,800~12,000)
11,500(2,800~14,000)
Btu/h
12,000(3,000~18,000) (10,600 at 17˚F)
13,800(3,000~23,000) (13,500 at 17˚F)
Moisture Removal
High
Pints/H
1.3
2.3
Dry Air Flow
High
CFM
405
530
SEER
Cooling
28.5
25.5
EER
Cooling
16.1
14.35
HSPF
Heating
V, Phase, Hz
A
2.5/2.8
3.8/4.2
A
4.0/4.5
5.2/5.8
Cooling
W
540(150-850)
800(150-1,050)
Heating
W
860(150-1,650)
1,150(150-2,100)
kW
---
---
A
15
20
Microprocessor
Microprocessor
Low Ambient Control
Equipped
Equipped
Wireless Remote Controller
Included
Included
Back-up Heater
Comparing inverter and non-inverter air conditioners to cars…
Adjusts the accelerator and
thus runs more economically.
The accelerator can't be adjusted, so you spend a long
time to get comfortable, then soon become uncomfortable.
Room temperature
Uncomfortable Reaches the comfortable
zone quickly.
Capacity
Panasonic’s Inverter Compressor can achieve high efficiency under
high load conditions. With accumulated production of 200 Million
compressors, extremely high quality and reliability are proven.
Wired Remote Controller (optional)
High Efficiency Motor
for wide operating voltage
Air Deflection
Optimum Shape
Muffler
for quiet operation
Rated capacity
2,800Btu/h
8,700Btu/h
Uncomfortable
*Image of output power fluctuation
The room gets too cold,
then too warm.
Inverter air conditioner
Non-inverter air conditioner
Microprocessor-Controlled
Operation
Microprocessor control ensures that the
temperature and humidity levels in the room are
always comfortable.
Operation Sound
In(Hi / Lo/ Q-Lo) dB-A
Refrigerant Piping
Type
Outdoor(Hi)
The graph shows CS-XE9PKUA's wide power
output range during cooling.
CZ-RD516C
5 Speeds + Auto
24hr Program
24hr Program
Manual
Manual
Automatic
Washable + Anti Microbial Filter
Washable + Anti Microbial Filter
dB-A
R-410A
R-410A
Electric Expansion Valve
Electric Expansion Valve
42 / 25 / 20
45 / 28 / 20
48
49
Flare
Flare
1/4”
Discharge
inches
1/4”
Suction
inches
3/8”
1/2”
Ft.
Max. 66
Max. 66
Outdoor Above
Ft.
Max. 49
Max. 49
Outdoor Below
Ft.
Max. 49
Refrigerant Pipe Length
Elevation Difference*
CZ-RD516C
5 Speeds + Auto
Dimensions & Weight
Wireless Remote Control
Automatic
Refrigerant control
Minimum capacity
12,000Btu/h
Runs at a fixed speed, so it takes
longer to reach the comfort zone.
Horizontal
Refrigerant
Even Wider Output Power Range
Maximum capacity
START
Timer
Vertical
Setting Temperature
Less Cool
Fan Speeds
Air Filter
Keeps the temperature
comfortable all the time.
Comfortable
Electric Refrigerant Control
Valve
Heat Mode
2 air guides to improve the air flow direction
Cooling Mode
Cool air doesn't reach
you directly so your
hands and feet don't
get cold
2 air
guides
Panasonic’s infrared Remote Control with and
easy to read LCD Display, gives the user the
capability to adjust & set: temperature, sweep
(louver control), fan speeds, timer and more, for
complete automatic operation.
Dry Mode
Max. 49
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
inches
11-5/8”
27-3/8”
11-5/8”
27-3/8”
Width
inches
34-9/32”
34-15/32”
34-9/32”
34-15/32”
Depth
inches
10-1/16”
12-5/8”
10-1/16”
12-5/8”
24
97
24
97
Height
Net Weight
Lbs.
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Warm feet and no direct
breeze on your face
mean even more
comfort
*This function may not be performed if the unit is
not energized, or under a certain condition that
unit is unable to operate such as in protection
mode. Please consult with the HVAC installers
Features
Inverter Compressor
The Advantages of Inverter Control
12.0
230/208V, 1PH, 60Hz
Heating
Controls
High Efficiency &
High Reliability Material
for longer life span and to
withstand high pressure
12.5
230/208V, 1PH, 60Hz
Cooling
Fuse or Circuit Breaker
Right from the start, air is warm and comfortable.
The Hot Start Heating System prevents any cold
blasts at the beginning while the heat pump is
warming up. (Heat pump unit only)
Cool/Dry
Mode
Heating Mode
Outdoor Unit
Heating
Power Input
Panasonic's inverter provides optimum power control and extremely efficient operation by
changing the power supply frequency. The result is speedy, flexible operation using less
electricity.
XE12PKUA
Indoor Unit
Performance & Electrical Ratings
Capacity
Cooling
Power Supply
Inverter Technology
The inverter constantly adjusts compressor rotation speed to provide optimum
performance at all times. After reaching the set temperature, an inverter air conditioner
continues operating with minimum power to avoid unnecessary electricity consumption.
Conventional non-inverter air conditioners can only operate at a constant speed, switching
the compressor ON and OFF to maintain the set temperature, which wastes electricity.
The air sweep function moves the louver up and
down in the air outlet, directing air in a “sweeping”
motion around the room and providing comfort in
every corner.
The circulation volume of the refrigerant is
controlled by a pulse type electric control valve.
In order to attain optimum efficiency, when the
power is switched ON, the opening degree of the
electric control valve is controlled between 90
and 480 step.
Quiet Mode
LOW, low fan speed for extra quiet operation.
Model No.
Breakthrough technologies such as the inverter enable the highest energy efficiency* in the
industry. Thanks to this exceptional performance, you enjoy even more comfort.
*CS/CU-XE9PKUA as of March 2013
Innovative Inverter Technology
Hot Start Heating System
Specifications
Running Amps
Cooler
Outdoor Unit
CU-XE9PKUA
CU-XE12PKUA
Air Sweep Control
2 air
guides
Leaves touch together
30dB
Whisper voice
40dB
In a library
50dB
In a office
60dB
Normal conversation
80dB
In a subway
Louver Control
Louver can be manually set to the desired angle
by remote control.
Automatic Heating and
Cooling Changeover
After setting the temperature and functions
you desire, just relax. If the room temperature
is higher than the set temperature, cooling
operation begins. If the room temperature
is lower than the set temperature, heating
operation begins. During normal thermostat
cycle operation, cooling and heating operations
automatically change in accordance with set
temperature, time and room temperature.
(Single Zone Heat Pump unit only)
24-hour Clock with ON/OFF
Program Timer
By coupling compressor and fan operation,
intermittent operation can be precisely controlled
according to room temperature, so that air is
efficiently dehumidified.
The remote control unit allows you to set a
wide variety of timer-based operations. Such
functions include automatic ON/OFF with a timer
setting, same time ON/OFF every day, ON timer,
OFF timer and Combination timer.
5 Fan Speeds and Automatic
Fan Operation
Automatic Restart Function
after Power Failure
Convenient microprocessor control automatically
adjusts fan speed to High, Medium or Low.
According to room temperature to maintain a
comfortable airflow throughout the room.
20dB
This feature allows the system to automatically
resume operation at its preset program, after
power is restored from a power failure when
the remote control is in the room.
Self-Diagnosing Function
Unit is equipped with Self Diagnosing Function
with remote controller. This makes it easier to
diagnose malfunctions, reducing service labors.
Blue Fin Condenser
Condensers can take a beating from exposure to
salty air, rain and other corrosive factors.
Panasonic has extended the life of its
condensers with an original anti-rust coating.
Special Coating Layer
(Fin Cross-section)
Water Air Salt content
Base material
Corrosion-resistant layer
Was this manual useful for you? yes no