Selection Guide ControlLogix System 1756 Series Catalog Numbers ControlLogix System Logix Controllers Comparison Characteristic ControlLogix® 1756-L81E, 1756-L82E, 1756-L83E, 1756-L84E, 1756-L85E ControlLogix 1756-L71, 1756-L72, 1756-L73, 1756-L73XT, 1756-L74, 1756-L75 GuardLogix® 1756-L71S, 1756-L72S, 1756-L73S Armor™ ControlLogix 1756-L72EROM Armor™ GuardLogix® 1756-L72EROMS CompactLogix™ 1769-L30ER, 1769-L30ER-NSE, 1769-L30ERM, 1769-L33ER, 1769-L33ERM, 1769-L36ERM CompactLogix 1769-L24ER-BB1B, 1769-L24ER-QBFC1B, 1769-L27ERM-QBFC1B CompactLogix 1769-L16ER-BB1B, 1769-L18ER-BB1B, 1769-L18ERM-BB1B, 1769-L19ER-BB1B Compact GuardLogix 1769-L30ERMS, 1769-L33ERMS, 1769-L36ERMS Controller tasks: • Continuous • Periodic • Event • 32 • 1000 programs/task • 32 • 100 programs/task (with V23 and earlier) • 1000 programs/task (with V24 and later) • 32 • 100 programs/task (with V23 and earlier) • 1000 programs/task (with V24 and later) • 32 • 100 programs/task • 32 • 100 programs/task • 32 • 100 programs/ task Event tasks Consumed tag, EVENT instruction triggers, Module Input Data changes, and motion events Consumed tag, EVENT instruction triggers, Module Input Data changes, and motion events Consumed tag, EVENT instruction triggers, Module Input Data changes, and motion events Consumed tag, EVENT instruction triggers and motion events Consumed tag, EVENT instruction triggers and motion events Consumed tag, EVENT instruction triggers and motion events User memory • • • • • • • • • • • 1756-L71: 2 MB 1756-L72: 4 MB 1756-L73, 1756-L73XT: 8 MB 1756-L74: 16 MB 1756-L75: 32 MB 1756-L71S: 2 MB + 1 MB safety • 1756-L72S: 4 MB +2 MB safety • 1756-L73S: 8 MB +4 MB safety • 1756-L72EROM: 4 MB • 1756-L72EROMS: 4 MB + 2 MB safety • 1769-L30ER, 1769-L30ER-NSE, 1769-L30ERM: 1 MB • 1769-L33ER, 1769-L33ERM: 2 MB • 1769-L36ERM: 3 MB • 1769-L30ERMS: 1 MB + 0.5 MB safety • 1769-L33ERMS: 2 MB + 1 MB safety • 1769-L36ERMS: 3 MB + 1.5 MB safety • 1769-L24ER: 750 KB • 1769-L27ERM: 1 MB • 1769-L16ER: 384 KB • 1769-L18ER, 1769-L18ERM: 512 KB • 1769L19ER-BB1B: 1 MB Built-in ports • Single-port EtherNet/IP™ • 1 port USB client 1 port USB Client • Dual-port EtherNet/IP • 1 port USB client • Dual-port EtherNet/IP • 1 port USB Client • Dual-port EtherNet/IP • 1 port USB Client • Dual-port EtherNet/IP • 1 port USB Client Communication options • • • • • • • • • • • • • • • EtherNet/IP • EtherNet/IP – Embedded switch – Single IP address • DeviceNet • USB Client • EtherNet/IP – Embedded switch – Single IP address • DeviceNet • USB Client • EtherNet/IP – Embedded switch – Single IP address • USB Client Controller connections N/A 500 connections 500 connections 256 connections 256 connections 256 connections Network nodes • • • • • N/A N/A N/A N/A N/A Controller redundancy Future Full support None Backup via DeviceNet Backup via DeviceNet None Integrated motion EtherNet/IP • EtherNet/IP • SERCOS • Analog EtherNet/IP EtherNet/IP EtherNet/IP EtherNet/IP Conformal coating Standard(1) Standard(1) Standard(1) Custom(2) Custom(2) Custom(2) 1756-L81E: 3 MB 1756-L82E: 5 MB 1756-L83E: 10 MB 1756-L84E: 20 MB 1756-L85E: 40 MB EtherNet/IP ControlNet™ DeviceNet™ Data Highway Plus™ Remote I/O SynchLink ™ USB Client 1756-L81E,: 60 1756-L82E: 80 1756-L83E: 100 1756-L84E: 150 1756-L85E: 300 EtherNet/IP ControlNet DeviceNet Data Highway Plus Remote I/O SynchLink USB Client (1) Available when you select the K version of the controller. (2) Contact the Rockwell Automation specialty products group for availability. 2 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Step 1 ControlLogix I/O Modules Select: • I/O modules—Some modules have field-side diagnostics, electronic fusing, or individually isolated inputs/outputs • A remote terminal block (RTB) or wiring system for each I/O module Page 10 Step 2 ControlLogix Integrated Motion Select: • An EtherNet/IP communication module for Integrated Motion • Associated cables • Select drives, motors, and accessories (use the Motion Analyzer software) Page 18 Step 3 ControlLogix Communication Modules Select: • Networks • Communication modules • Associated cables and network equipment • Sufficient modules and cables if you are planning a redundant system Page 19 Step 4 ControlLogix Controllers Page 24 Step 5 ControlLogix Chassis Select a controller: • Standard ControlLogix controller • Redundant ControlLogix controller • Safety GuardLogix controller • Extreme environment ControlLogix controller • Standard Armor ControlLogix controller • Safety Armor GuardLogix controller Select: • A chassis with sufficient slots • Slot fillers for empty slots Page 30 Step 6 ControlLogix Power Supplies Select: • One power supply for each chassis, if you are using standard power supplies • A power supply bundle if you are planning a redundant power supply system Page 31 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 3 Select a ControlLogix System ControlLogix System Overview The ControlLogix system provides discrete, drives, motion, process, and safety control together with communication and state-of-the-art I/O in a small, cost-competitive package. The system is modular, so you can design, build, and modify it efficiently with significant savings in training and engineering. Example Configuration—ControlLogix System A simple ControlLogix system consists of a standalone controller and I/O modules in one chassis. For a more comprehensive system, use the following: • Multiple controllers in one chassis • Multiple controllers joined across networks • I/O in multiple platforms that are distributed in many locations and connected over multiple I/O links PowerMonitor™ 5000 Stratix 5700™ PanelView™ Plus 7 Stratix 5700 1715 I/O ControlLogix ControlLogix 1794 FLEX™ I/O Dynamix™ 1444 PowerFlex® 755 4 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Conformal Coating A conformal coating solution is offered on select ControlLogix products. Conformal coating helps protect the assembly by providing a layer of protection against contaminants and humidity to extend product life in harsh, corrosive environments. Conformally coated products have a ‘K’ suffix at the end of the catalog number, such as 1756-A4K. Conformally coated, AllenBradley® products meet or exceed these requirements: • ANSI/ISA 71.04.2013 G3 Environment (10-year exposure) • IEC 61086-3-1 Class 2 • IPC-CC-830 • MIL-I-46058C • EN600068-2-52 salt mist test, severity level 3 The most current list of conformally coated products can be found by contacting your local Rockwell Automation distributor, sales office, or at the following location: http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/ControlLogix-System.html ControlLogix-XT System ControlLogix-XT™ (Extended Temperature) controllers function the same way as traditional ControlLogix controllers with an extended temperature range. The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh, corrosive environments: • The standard ControlLogix system can withstand temperature ranges from 0…60 °C (33…140 °F). • When used independently, the ControlLogix-XT system can withstand temperature ranges from -25…70 C (-13…158 F). Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 5 Select a ControlLogix System Example Configuration—Redundant ControlLogix System The 1756-L7 ControlLogix controller supports controller redundancy. Workstation EtherNet/IP Switch 1715 Redundant I/O 6 1756 ControlLogix I/O 1734 POINT I/O™ Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 PowerFlex 755 Drive 1756-EN2T 1756-EN2T 1756-EN2T 1756-EN2TR 1756-EN2TR 1756-RM2 1734-I/O 1734-AENTR 1756-OB16D 1756-IB16ISOE 1756-IB16ISOE 1756-L75 1756-EN2T 1756-EN2T 1756-EN2T 1756-EN2TR 1756-EN2TR 1756-EN2TR 1715-I/O 1715-I/O 1715-I/O 1715-I/O 1715-AENTR 1715-AENTR 1756-L75 1756-RM2 Redundant Chassis Pair Select a ControlLogix System Example Configuration—Redundant I/O System The 1715 redundant I/O system lets a 1756-L7 ControlLogix controller communicate to a remote, redundant I/O chassis over an EtherNet/IP network. The 1715 redundant I/O system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and redundant I/O module pairs. The redundant I/O system must be connected to a 1756-L7 ControlLogix system via an EtherNet/IP network. All connections are established via the Ethernet network by using the topologies that the 1756-EN2TR communication bridge supports. TERMINAL IDENTITY CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 AOTA Dual. AOTA Dual. 1715-I/O AOTA Dual. 1715-I/O 1715-I/O TERMINAL IDENTITY CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 AOTA Dual. 1715-I/O TERMINAL IDENTITY CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 AOTA Dual. IO BASE 1715-A310 1715-I/O 1715-AENTR 1715-AENTR TERMINAL IDENTITY CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 IO BASE 1715-A310 TERMINAL IDENTITY CH1 CH1 CH1 CH1 1715-I/O TERMINAL IDENTITY AOTA Dual. 1756-RM2 1756-EN2TR 1756-L7 ControlLogix Secondary Chassis 1756-RM2 1756-EN2TR 1756-L7 ControlLogix Primary Chassis 1715 Redundant I/O System For detailed specifications, see the 1715 Redundant I/O System Specifications Technical Data, publication 1715-TD001. Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 7 Select a ControlLogix System GuardLogix Safety System A GuardLogix controller is a ControlLogix controller that also provides safety control. The GuardLogix system is a dual controller solution—you must use a GuardLogix controller with the appropriate safety partner to achieve SIL 3/PLe/Cat. 4. A major benefit of this system is that it is still one project, safety, and standard together. The safety partner controller is a part of the system, is automatically configured, and requires no user setup. Application Description Up to and including SIL 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3, according to IEC 61508, and applications up to and including category (PLe/Cat. 4), according to ISO 13849-1. For more information, see the following: • GuardLogix 5570 Controllers User Manual, publication 1756-UM022, provides information on how to install, configure, and operate GuardLogix 5570 controllers in the Studio 5000 Automation Engineering & Design Environment™ projects, version 21 or later. • GuardLogix 5570 Controller System Safety Reference Manual, publication 1756-RM099, provides information on how to meet safety application requirements for GuardLogix 5570 controllers in Studio 5000® projects, version 21 or later. • GuardLogix Controllers User Manual, publication 1756-UM020, provides information on how to install, configure, and operate GuardLogix 5560 and GuardLogix 5570 controllers in RSLogix 5000® projects, version 20 or earlier. • GuardLogix Controller Systems Safety Reference Manual, publication 1756-RM093, provides information on how to meet safety application requirements for GuardLogix 5560 and GuardLogix 5570 controllers in RSLogix 5000 projects, version 20 or earlier. • GuardLogix Safety Application Instruction Set Safety Reference Manual, publication 1756-RM095, provides programmers with details about the GuardLogix safety application instruction set. SIL 2 Components of the ControlLogix system are type-approved and certified for use in SIL 2 applications, according to IEC 61508. For a list of ControlLogix system components that meet SIL 2 requirements, see the Using ControlLogix in SIL 2 Applications Safety Reference Manual, publication 1756-RM001. Stratix 5100™ PowerMonitor 1000 RS-485 TM conformance tested RS-485 RX + ACT PanelView Plus 7 - TX STATUS Mod GuardLogix Powermonitor 1000 Net SHLD LNK Stratix 5700 1734 POINT Guard I/O™ PowerFlex 525 8 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Armor ControlLogix and Armor GuardLogix Systems On-Machine™ standard and safety controllers support the same temperature range of ControlLogix, while offering global certifications and ratings and Ingress Protection (IP67) for dust and wash-down protection for immersion between 15 cm…1 m (5.91…393.70 in.) in harsher environments. ArmorStratix™ 5700 Armor ControlLogix 280E Networked ArmorStart® 1738-AENTR ArmorPOINT® 1732E ArmorBlock® Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 9 Select a ControlLogix System ControlLogix I/O Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications, from highspeed digital to process control. The ControlLogix architecture uses a Producer/Consumer model so that input information and output status can be shared among multiple controllers. Each ControlLogix I/O module mounts in a ControlLogix chassis and requires a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For detailed specifications, see 1756 ControlLogix I/O Modules Specifications Technical Data, publication 1756-TD002. AC Digital Input Modules Cat. No. Inputs/Outputs Voltage Category Operating Voltage Range Removable Terminal Block 1756-IA8D 8 diagnostic inputs (4 points/group) 120V AC 79…132V AC 1756-TBNH 1756-TBSH 1756-IA16 16 inputs (8 points/group) 120V AC 74…132V AC 1756-TBNH 1756-TBSH 1756-IA16I 16 individually isolated inputs 120V AC 74…132V AC 1756-TBCH 1756-TBS6H 1756-IA32 32 inputs (16 points/group) 120V AC 74…132V AC 1756-TBCH 1756-TBS6H 1756-IM16I 16 individually isolated inputs 240V AC 159…265V AC 1756-TBCH 1756-TBS6H 1756-IN16 16 inputs (8 points/group) 24V AC 10…30V AC 1756-TBNH 1756-TBSH AC Digital Output Modules Cat. No. Inputs/Outputs Voltage Category Operating Voltage Range Removable Terminal Block 1756-OA8 8 outputs (4 points/group) 120/240V AC 79…265V AC 1756-TBNH 1756-TBSH 1756-OA8D 8 diagnostic, electronically fused outputs (4 points/group) 120V AC 74…132V AC 1756-TBNH 1756-TBSH 1756-OA8E 8 electronically fused outputs (4 points/group) 120V AC 74…132V AC 1756-TBNH 1756-TBSH 1756-OA16 16 mechanically fused/group outputs (8 points/group) 120/240V AC 74…265V AC 1756-TBNH 1756-TBSH 1756-OA16I 16 individually isolated outputs 120/240V AC 74…265V AC 1756-TBCH 1756-TBS6H 1756-ON8 8 outputs (4 points/group) 24V AC 10…30V AC, current > 50 mA 16…30V AC, current < 50 mA 1756-TBNH 1756-TBSH 10 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System DC Digital Input Modules Cat. No. Inputs/Outputs Voltage Category Operating Voltage Range Removable Terminal Block 1756-IB16 16 inputs (8 points/group) 12/24V DC sink 10…31.2V DC 1756-TBNH 1756-TBSH 1756-IB16D 16 diagnostic inputs (4 points/group) 12/24V DC sink 10…30V DC 1756-TBCH 1756-TBS6H 1756-IB16I 16 individually isolated inputs 12/24V DC sink/source 10…30V DC 1756-TBCH 1756-TBS6H 1756-IB16IF 16 high-speed, individually isolated inputs 12/24V DC sink/source 10…30V DC 1756-TBCH 1756-TBS6H 1756-IB16ISOE 16 individually isolated, sequence of events inputs 24/48V DC sink/source 10…55V DC 1756-TBCH 1756-TBS6H 1756-IB32 32 inputs (16 points/group) 12/24V DC sink 10…31.2V DC 1756-TBCH 1756-TBS6H 1756-IC16 16 inputs (8 points/group) 48V DC sink 30…55V DC @ 60 °C (140 °F) 30…60V DC @ 55 °C (131 °F) 1756-TBNH 1756-TBSH 1756-IG16 16 inputs (8 points/group) 5V DC TTL source (Low = True) 4.5…5.5V DC 1756-TBNH 1756-TBSH 1756-IH16I 16 individually isolated inputs 125V DC sink/source 90…146V DC 1756-TBCH 1756-TBS6H 1756-IH16ISOE 16 individually isolated, sequence of events inputs 125V DC sink/source 90…140V DC 1756-TBCH 1756-TBS6H 1756-IV16 16 inputs (8 points/group) 12/24V DC source 10…30V DC 1756-TBNH 1756-TBSH 1756-IV32 32 inputs (16 points/group) 12/24V DC source 10…30V DC 1756-TBCH 1756-TBS6H Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 11 Select a ControlLogix System DC Digital Output Modules Cat. No. Inputs/Outputs Voltage Category Operating Voltage Range Removable Terminal Block 1756-OB8 8 outputs 12/24V DC source 10…30V DC 1756-TBNH 1756-TBSH 1756-OB8EI 8 electronically fused, individually isolated outputs 12/24V DC source 10…30V DC 1756-TBCH 1756-TBS6H 1756-OB8I 8 individually isolated outputs 12/24V DC source 10…30V DC 1756-TBCH 1756-TBS6H 1756-OB16D 16 diagnostic outputs (8 points/group) 24V DC source 19.2…30V DC 1756-TBCH 1756-TBS6H 1756-OB16E 16 electronically fused outputs (8 points/group) 12/24V DC source 10…31.2V DC 1756-TBNH 1756-TBSH 1756-OB16I 16 individually isolated outputs 12/24V DC sink/source 10…30V DC 1756-TBCH 1756-TBS6H 1756-OB16IEF 16 high-speed, individually isolated, 24V DC sink/source electronically-fused outputs 10…30V DC 1756-TBCH 1756-TBS6H 1756-OB16IEFS 16 scheduled, high-speed, individually isolated, electronically-fused outputs 24V DC sink/source 10…30V DC 1756-TBCH 1756-TBS6H 1756-OB16IS 16 individually isolated outputs 8 scheduled outputs 12/24V DC sink/source 10…30V DC 1756-TBCH 1756-TBS6H 1756-OB32 32 outputs (16 points/group) 12/24V DC source 10…31.2V DC 1756-TBCH 1756-TBS6H 1756-OC8 8 outputs (4 points/group) 48V DC source 30…60V DC 1756-TBNH 1756-TBSH 1756-OG16 16 (8 points/group) 5V DC TTL source (Low=True) 4.5…5.5V DC 1756-TBNH 1756-TBSH 1756-OH8I 8 individually isolated outputs 120V DC 90…146V DC 1756-TBCH 1756-TBS6H 1756-OV16E 16 electronically fused outputs (8 points/group) 12/24V DC sink 10…30V DC 1756-TBNH 1756-TBSH 1756-OV32E 32 electronically fused outputs (16 points/group) 12/24V DC sink 10…30V DC 1756-TBCH 1756-TBS6H Contact Output Modules Cat. No. Inputs/Outputs Operating Voltage Range Removable Terminal Block 1756-OW16I 16 normally open, individually isolated outputs 5…125V DC 10…240V AC 1756-TBCH 1756-TBS6H 1756-OX8I 8 normally open 8 normally closed, individually isolated outputs (2 points/group) 5…125 DC 10…240V AC 1756-TBCH 1756-TBS6H 12 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Analog Input Modules Cat. No. Inputs/Outputs Range Resolution Removable Terminal Block 1756-IF6CIS 6 individually isolated inputs, current sourcing 0…20 mA (over-range indication when exceeded) 16 bits 0.34 A/bit 1756-TBNH 1756-TBSH 1756-IF6I 6 individually isolated inputs ±10.5V 0…10.5V 0…5.25V 0…21 mA 16 bits 10.5V: 343 V/bit 0…10.5V: 171 V/bit 0…5.25V: 86 V/bit 0…21 mA: 0.34 A/bit 1756-TBNH 1756-TBSH 1756-IF8 8 single-ended inputs 4 differential inputs 2 high-speed differential inputs ±10V 0…10V 0…5V 0…20 mA ±10.25V: 320 V/cnt (15 bits plus sign bipolar) 0…10.25V: 160 V/cnt (16 bits) 0…5.125V: 80 V/cnt (16 bits) 0…20.5 mA: 0.32 A/cnt (16 bits) 1756-TBCH 1756-TBS6H 1756-IF8H 8 differential voltage or current inputs, HART interface ±10V 0…5V 1…5V 0…10V 0…20 mA 4…20 mA 16…21 bits 1756-TBCH 1756-TBS6H 1756-IF8I 8 individually isolated inputs, current or voltage ±10V 0…10V 0…5V 0…20 mA 24 bits ±10.5V (1.49 V/count) 0…10.5V (1.49 V/count) 0…5.25V (1.49 V/count) 0…21 mA (2.99 nA/count) 1756-TBCH 1756-TBS6H 1756-IF8IH 8 individually isolated current inputs 0…20 mA 4…20 mA 16…21 bits 1756-TBCH 1756-TBS6H 1756-IF16 16 single-ended inputs 8 differential or 4 differential (high speed) inputs ±10V 0…10V 0…5V 0…20 mA 16 bits 10.5V: 343 V/bit 0…10.5V: 171 V/bit 0…5.25V: 86 V/bit 0…21 mA: 0.34 A/bit 1756-TBCH 1756-TBS6H 1756-IF16H 16 differential current inputs, HART interface 0…20 mA 4…20 mA 16…21 bits 1756-TBCH 1756-TBS6H Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 13 Select a ControlLogix System Analog RTD and Thermocouple Modules Cat. No. Inputs/Outputs Range Resolution Removable Terminal Block 1756-IR6I 6 individually isolated RTD inputs 1…487 2…1000 4…2000 8…4000 16 bits 1…487 : 7.7 m/bit 2…1000 : 15 m/bit 4…2000 : 30 m/bit 8…4020 : 60 m/bit 1756-TBNH 1756-TBSH 1756-IRT8I 8 individually isolated inputs, RTD or thermocouple inputs (2 CJC) 1…500 2…1000 4…2000 8…4000 -100…100 mV 24 bits 0…5100.06 m/count 0…10200.12 m/count 0…20400.25 m/count 0…40800.50 m/count -101…101 mV: 0.01 V/count 1756-TBCH 1756-TBS6H 1756-IR12 12 channels RTD mode 1…500 2…1000 4…2000 8…4000 24 bits 0…5100.06 m/count 0…10200.12 m/count 0…20400.25 m/count 0…40800.50 m/count 1756-TBCH 1756-TBS6H 1756-IT16 16 channels, thermocouple mode 2 CJC -100…100 mV 24 bits -101…101 mV: 0.01 V/count 1756-TBCH 1756-TBS6H 1756-IT6I 6 individually isolated thermocouple inputs 1 CJC -12…78 mV -12…30 mV 16 bits -12…78 mV: 1.4 V/bit -12…30 mV: 0.7 V/bit 1756-TBNH 1756-TBSH 1756-IT6I2 6 individually isolated thermocouple inputs 2 CJC -12…78 mV (1.4 V per bit) 16 bits -12…30 mV (0.7 V per bit) -12…78 mV: 1.4 V/bit -12…30 mV: 0.7 V/bit 1756-TBNH 1756-TBSH Analog Output Modules Cat. No. Inputs/Outputs Range Resolution Removable Terminal Block 1756-OF4 4 voltage or current outputs ±10V 0…20 mA Voltage: 15 bits across 10.5V, 320 V/bit Current: 15 bits across 21 mA, 650 nA/bit 1756-TBNH 1756-TBSH 1756-OF6CI 6 individually isolated outputs, current 0…21 mA 13 bits across 21 mA (2.7 A) 1756-TBNH 1756-TBSH 1756-OF6VI 6 individually isolated outputs, voltage ±10.5V 14 bits across 21V (1.3 mV) (13 bits across 10.5V +sign bit) 1756-TBNH 1756-TBSH 1756-OF8 8 voltage or current outputs ±10V 0…20 mA 15 bits across 21 mA - 650 nA/bit 15 bits across 10.4V - 320 V/bit 1756-TBNH 1756-TBSH 1756-OF8H 8 voltage or current outputs, HART interface ±10V 0…20 mA 4…20 mA 15…16 bits 1756-TBNH 1756-TBSH 1756-OF8I 8 individually isolated outputs, current or voltage ±10V 0…10V 0…5V 0…20 mA 16 bit ±10.5V (0.32 mV/count) 0…10.5V (0.16 mV/count) 0…5.25V (0.08 mV/count) 0…21 mA (0.32 μA/count) 1756-TBCH 1756-TBS6H 1756-OF8IH 8 individually isolated current outputs 0…20 mA 4…20 mA 15 bits across 24 mA, 732 nA per bit 1756-TBCH 1756-TBS6H 14 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Analog Combination Input and Output Module Cat. No. Inputs/Outputs Range Resolution Removable Terminal Block 1756-IF4FXOF2F 4 high-speed, submillisecond, differential inputs 2 high-speed voltage or current outputs Input: ±10V 0…10V 0…5V 0…20 mA Output: ±10V 0…20 mA Input: Approx 14 bits across ±10V DC (21V total) ±10V: 1.3 mV/bit, 14-bit effective 0…10.5V: 1.3 mV/bit, 13-bit effective 0…5.25V: 1.3 mV/bit, 12-bit effective Approx 12 bits across 21 mA 0…21 mA: 5.25 A/bit Output: 13 bits across 21 mA = 2.8 A/bit 14 bits across 21.8V = 1.3 mV/bit 1756-TBCH 1756-TBS6H Specialty I/O Modules Cat. No. Inputs/Outputs Description Removable Terminal Block 1756-CFM 4 inputs (2 per channel) 2 outputs, current sourcing Configurable flowmeter module 2 Flowmeter (F) inputs used for all modes 2 Gate inputs used in Totalizer mode for prover/store count 1756-TBNH 1756-TBSH 1756-HSC 2 counters, each with 3 inputs (A, B, Z for gate/reset) High-speed counter module 4 outputs (2 points/group) 5V operation: 4.5…5.5V DC 12/24V operation: 10…26.4V DC 1756-TBCH 1756-TBS6H 1756-LSC8XIB8I 8…24V DC counters 8 individually isolated, standard inputs, or counters 1756-TBCH 1756-TBS6H 1756-PLS Left section: 2 groups of 4 outputs and 4 inputs each Programmable limit switch module Center section: resolver interface and I/O control Right section: 2 groups of 4 outputs and 4 inputs each Low speed counter module 8…40 kHz 24V DC counters 8 individually isolated 12/24V DC low speed (max frequency 40 kHz) counters 8 individually isolated high-speed 12/24V DC sink/source standard or counter control inputs Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Requires 3 RTBs: 1756-TBNH or 1756-TBSH 15 Select a ControlLogix System HART Smart Instrumentation HART (Highway Addressable Remote Transducer) is an open protocol that is designed to connect analog devices. For HART connectivity, select products available from Rockwell Automation and our Encompass™ Partner. Typical HART Configuration • ControlLogix • 1756-IF8H or • 1756-OF8H HART Devices HART Interfaces If your application has Select Description Analog and HART connectivity in one module No external hardware is required to access HART signal HART commands can be transmitted as unscheduled messages Supports asset management software to HART device 1756-IF8H 1756-IF16H 1756-OF8H Rockwell Automation® analog I/O modules Analog and HART connectivity in one module No external hardware is required to access HART signal HART commands can be transmitted as unscheduled messages Supports asset management software to HART device Provides current isolation 1756-IF8IH 1756-OF8IH Rockwell Automation isolated analog I/O modules Data acquisition or control application with slow update requirements (such as a tank farm) No external hardware is required to access HART signal Does not connect directly to asset management software MVI56-HART ProSoft interface Analog and HART in one module Instrumentation in hazardous locations (FLEX Ex™ modules) HART commands can be transmitted as unscheduled messages Directly connects asset management software to HART devices 1794 FLEX I/O 1797 FLEX Ex I/O There are FLEX I/O and FLEX Ex modules that are designed for HART systems. These catalog numbers end in an H, such as 1797-IE8H. 16 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Accessories—I/O Modules 1756 Removable Terminal Blocks Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 I/O modules. The RTB plugs into the front of the I/O module. The type of module determines the RTB you need. You can choose screw-clamp or spring-clamp RTBs. RTBs are not shipped with I/O modules. You must order them separately. The standard housing on the front of the wiring arm is not necessarily deep enough for 2.5 mm2 (14 AWG) wiring. If you plan to use 2.5 mm2 (14 AWG) wiring, also order the extended housing. For more information on Extended-Depth Housing, see Rockwell Automation Knowledgebase article #41488, Use of the 1756-TBE Extended Terminal Housing. You can access the article at: https://rockwellautomation.custhelp.com/ (login is required). Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE Description 20-position NEMA screw-clamp removable block 20-pin spring-clamp removable terminal block with standard housing 36-pin cage-clamp removable terminal block with standard housing 36-pin spring-clamp removable terminal block with standard housing Extended-depth terminal block housing Screw torque 0.8…1 N•m 7…9 lb•in 0.4 N•m 4.4 lb•in — Wiring Systems As an alternative to buying RTBs and connecting the wires yourself, you can buy a wiring system of the following: • Interface modules (IFMs) that provide the I/O terminal blocks for Digital I/O modules. Use the prewired cables that match the I/O module to the IFM. • Analog interface modules (AIFMs) that provide the I/O terminal blocks for analog I/O modules. Use the prewired cables that match the I/O module to the AIFM. • I/O module-ready cables. One end of the cable assembly is an RTB that plugs into the front of the I/O module. The other end has individually color-coded conductors that connect to a standard terminal block. I/O Module RTB Prewired Cable Interface Module (IFM) Factory-wired Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Field Wiring 17 Select a ControlLogix System ControlLogix Integrated Motion The Logix architecture supports motion control components that work in a wide variety of machine architectures: • Integrated Motion on the EtherNet/IP network supports a connection to Ethernet drives. • The Kinetix® integrated-motion solution uses a SERCOS or EtherNet/IP interface to perform multi-axis, synchronized motion. • Logix integrated motion supports the analog family of servo modules for controlling drives/actuators. • Networked motion provides connection via the DeviceNet network to one axis drive to perform point-to-point indexing. For detailed specifications on motion interface modules, see the 1756 ControlLogix Integrated Motion Modules Specifications Technical Data, publication 1756-TD004. For more information, see these publications: • Motion Analyzer CD to size your motion application and to make final component selection Download the software from https://motionanalyzer.rockwellautomation.com/ • Kinetix Motion Control Selection Guide, publication GMC-SG001, to verify drive, motor, and accessory specifications Integrated Motion on an EtherNet/IP Network Product Consideration Drive that supports EtherNet/IP connections Unlimited velocity, torque, and VHz configured drives: • Kinetix 6500 drives • Kinetix 5700 drives • Kinetix 5500 drives • Kinetix 350 drives • PowerFlex 755 drives • PowerFlex 527 drives ControlLogix controller • 1756-L7: as many as 100 drives per controller • 1756-L8: as many as 256 drives per controller ControlLogix EtherNet/IP communication module • 1…8 position loop axes that are configured with the 1756-EN2T or 1756-EN2TR modules • 1…128 position loop axes that are configured with the 1756-EN3TR module ControlLogix L8 Controller Logix5585E Logix5585E SAFETY ON SAFETY ON NET NET LINK LINK LNK1 LNK2 NET RUN REM PROG RUN REM OK PROG 1 PanelView Plus 7 2 1 Gb 100 Mb 1 Gb 100 Mb Stratix 5400™ 1 2 3 4 5 6 7 8 9 10 11 12 25 26 2 1 1 4 5 10/100/1000 PoE+ 8 9 12 13 16 17 100/1000 SFP 20 21 24 IN Disp. Mode IN OUT PoE Out PRP GPS DLR 2 1 Setup 3 4 Speed EIP Net Alarms PSU Duplex TimeCD EIP Mod 13 14 15 16 17 18 19 20 21 22 23 24 27 28 OUT GPS ANT. DIG.TimeCode 25 100/1000 SFP+ TOD ANA.TimeCode Express Setup 28 Console Alarm Stratix 5700 AUTO At Reference 6 0 . 00 Hz F PowerFlex 755 480V 4.2A 20G . . . B4P2 00 ESC REF 7 4 1 8 5 2 STS ENET LINK PAR# TEXT Mod Net Mod Net Mod Net 5700 5700 5700 9 6 3 0 755 Kinetix 5700 CAUTION HOT surfaces can cause severe burns 5069-IB16 5069-FPD 5069-ARM PowerFlex 755 COMPACT I/O 5069-AEN2TR with Compact I/O™ 18 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System ControlLogix Communication Modules Separate communication modules are available for different networks. Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks. You can route a message through a maximum of four chassis (eight communication hops). You do not need a ControlLogix controller in the chassis. Application Network Page • • • • • • • • Plant management (material handling) Configuration, data collection, and control on one high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) Internet/Intranet connection High-speed transfer of time-critical data between controllers and I/O devices Integrated Motion on the EtherNet/IP network and safety Redundant controller systems EtherNet/IP 19 • • • • • High-speed transfer of time-critical data between controllers and I/O devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems ControlNet 20 • • • • Connections of low-level devices directly to plant floor controllers, without interfacing them through I/O modules Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional, hard-wired system DeviceNet 20 • Plant-wide and cell-level data sharing with program maintenance • Data sent regularly • Transfer of information between controllers Data Highway Plus 21 • Connections between controllers and I/O adapters • Data sent regularly • Distributed control so that each controller has its own I/O and communicates with a supervisory controller Remote I/O 21 • Fieldbus transmitters and actuators • Closed-loop control • Process automation Foundation Fieldbus 22 For detailed specifications, see the 1756 ControlLogix Communication Modules Specifications Technical Data, publication 1756-TD003. EtherNet/IP Communication Modules EtherNet/IP (Ethernet Industrial Protocol) is an open industrial-networking standard that supports real time I/O messaging and message exchange. The EtherNet/IP network uses off-the-shelf Ethernet communication chips and physical media. Cat. No. Description Media Communication Rate Integrated Motion TCP/IP on the EtherNet/IP Connections Network Axes, max Logix Connections 1756-EN2F EtherNet/IP bridge, fiber Fiber 100 Mbps 8 128 256 1756-EN2T EtherNet/IP bridge, copper Copper 10/100 Mbps 8 128 256 1756-EN2TR EtherNet/IP bridge, embedded switch, copper Dual copper 10/100 Mbps 8 128 256 1756-EN3TR EtherNet/IP bridge, embedded switch, copper Dual copper 10/100 Mbps 128 128 256 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 19 Select a ControlLogix System Cat. No. Description Media Communication Rate Integrated Motion TCP/IP on the EtherNet/IP Connections Network Axes, max Logix Connections 1756-EN2TXT ControlLogix-XT, extended temperature EtherNet/IP bridge, copper for extreme environments Copper 10/100 Mbps 8 128 256 1756-EN2TRXT ControlLogix-XT, extended temperature EtherNet/IP bridge, embedded switch, copper Dual copper 10/100 Mbps 8 128 256 1756-EN2TSC EtherNet/IP secure communication module Copper 10/100 Mbps — 128 256 1756-ENBT EtherNet/IP bridge, copper Copper 10/100 Mbps — 64 128 1756-EWEB Ethernet web server module Copper 10/100 Mbps — 64 128 ControlNet Communication Modules The ControlNet network combines the functionality of an I/O network and a peer-to-peer network, providing high-speed performance. The ControlNet network provides deterministic, repeatable transfers of critical control data. Cat. No. 1756-CN2 1756-CN2R 1756-CNB 1756-CNBR 1756-CN2RXT Description ControlNet bridge, standard media ControlNet bridge, redundant media ControlNet bridge, standard media ControlNet bridge, redundant media ControlLogix-XT, extended temperature ControlNet bridge, redundant media Communication Rate Logix Connections Number of Nodes 5 Mbps 128(1) 99 5 Mbps 128(1) 99 5 Mbps 64(2) 99 5 Mbps 64(2) 99 5 Mbps 128(1) 99 (1) 128 connections are available for standard use. An extra three connections are reserved for redundant control. (2) Recommend using only 40…48 Logix connections for I/O. DeviceNet Communication Module The DeviceNet network provides connections between simple, industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers). Cat. No. Description Communication Rate Number of Nodes 1756-DNB DeviceNet bridge 125 Kbps (500 m max) 250 Kbps (250 m max) 500 Kbps (100 m max) 64 20 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Data Highway Plus and Remote I/O Communication Modules The Data Highway Plus network supports messaging between devices. The remote I/O link connects to remote I/O chassis and other intelligent devices. The 1756-DHRIO module supports messaging between devices on DH+™ networks. The remote I/O functionality enables the module to act as a scanner for transferring digital and block transfer data to and from remote I/O devices. The 1756-RIO module can act as a scanner or adapter on a remote I/O network. The 1756-RIO transfers digital, block transfer, analog, and speciality data without message instructions. Cat. No. Description Communication Rate DH+ Connections RIO Connections 1756-DHRIO Data Highway Plus/Remote I/O two-channel communication module 57.6 Kbps, 115.2 Kbps, 230.4 Kbps 32 DH+ messages Remote I/O scanner only per DH+ module 32 logical rack connections per remote I/O channel 16 block transfer connections per remote I/O channel 1756-RIO Remote I/O communication module 57.6 Kbps, 115.2 Kbps, 230.4 Kbps — 1756-DHRIOXT ControlLogix-XT, extended temperature Data Highway Plus/ Remote I/O two-channel communication module 57.6 Kbps, 115.2 Kbps, 230.4 Kbps 32 DH+ messages Remote I/O scanner only per DH+ module 32 logical rack connections per remote I/O channel 16 block transfer connections per remote I/O channel Maximum Recommended Logix Connections 32 Remote I/O scanner or adapter 10 scheduled I/O 32 physical racks (0…76), any combination of rack size and block transfers 32 Accessories: DH+ and Remote I/O Networks Cat. No. Description Specifications 1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial 9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes the following: • Pre-configured modem • Communication module • DIN rail mounting hardware • Associated cables Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 21 Select a ControlLogix System FOUNDATION Fieldbus Linking Devices The FOUNDATION Fieldbus protocol is a network that is designed for distributed control of process applications. Cat. No. Description Communication Rate Number of H1 Ports Devices per H1 Link Devices per Linking Device 1757-FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network FOUNDATION Fieldbus: 31.25 Kbps EtherNet/IP: 10/100 Mbps 2 16 (8…10 recommended) 32 FOUNDATION Fieldbus bridge to a ControlNet network FOUNDATION Fieldbus: 31.25 Kbps ControlNet: 5 Mbps 2 16 (8…10 recommended) 32 1757-FFLD4 1757-FFLDC2 1757-FFLDC4 4 4 64 64 Example Configuration—Bridge to EtherNet/IP Network • FactoryTalk® View SE • RSFieldbus™ • Studio 5000 Environment HSE/IP 1757-FFLD4 H1(1) H1(2) H1(3) H1(4) 22 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Other Connectivity Options Option Consideration USB connection The ControlLogix controllers have a USB port in place of the serial port.(1) If your application requires RS-232 functionality, see the many Encompass Partners’ products at http://www.rockwellautomation.com/encompass. DH-485 network The controller serial port is compatible with DH-485 communication. The DH-485 connection does support remote programming and monitoring via the Logix Designer application. Or, add a 1756-DH485 communication module. SynchLink™ network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control. The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link. (1) The USB port is intended only for temporary local programming purposes and not intended for permanent connection. Do not use the USB port in hazardous locations. Modbus Support To access a Modbus TCP network, use one of the following methods: • Connect through the 1756-EN2T, 1756-EN2TR, 1756-EN2F, or 1756-EN3TR modules, with firmware revision 5.007 or later and execute a ladder-logic routine. • Connect through the 1756-EWEB module, with firmware revision 4.006 or later and execute a ladder-logic routine. For more information, see Knowledgebase document 470365 at http://www.rockwellautomation.com/knowledgebase/. To access a Modbus RTU network, connect through the serial port (if available) and execute a ladder-logic routine. For more information, see Using Logix5000™ Controllers as Masters or Slaves on Modbus Application Solution, publication CIG-AP129. Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 23 Select a ControlLogix System ControlLogix Controllers The ControlLogix controller provides a scalable controller solution capable of addressing many I/O points. The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis. Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently. ControlLogix controllers can monitor and control I/O across the ControlLogix backplane, and over I/O links. ControlLogix controllers can communicate over EtherNet/IP, ControlNet, DeviceNet, DH+, Remote I/O, and RS-232-C (DF1/DH-485 protocol) networks and many third-party process and device networks. To provide communication for a ControlLogix controller, install the appropriate communication interface module into the chassis. Cat. No. Description User Memory 1756-L81E ControlLogix controller, 1 built-in USB port(1), single port EtherNet/IP 3 MB 1756-L82E 5 MB 1756-L83E 10 MB 1756-L84E 20 MB 1756-L85E 1756-L71 40 MB ControlLogix controller, 1 built-in USB port(1) 2 MB 1756-L72 4 MB 1756-L73 8 MB 1756-L74 16 MB 1756-L75 32 MB 1756-L73XT ControlLogix-XT controller, extreme environment 8 MB 1756-L71S GuardLogix safety controllers 2 MB standard 1 MB safety 1756-L72S 4 MB standard 2 MB safety 1756-L73S 8 MB standard 4 MB safety 1756-L7SP GuardLogix safety partner (one is required for each GuardLogix L7 controller) — 1756-L72EROM Armor ControlLogix controllers, EtherNet/IP dual port 4 MB 1756-L72ERMOS Armor GuardLogix controllers, EtherNet/IP dual port 4 MB standard 2 MB safety (1) The USB port is intended only for temporary local programming purposes and not intended for permanent connection. Do not use the USB port in hazardous locations. For detailed specifications, see the 1756 ControlLogix Controllers Technical Data, publication 1756-TD001. 24 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Standard ControlLogix Controllers The ControlLogix controller is part of the Logix5000 family of controllers. A ControlLogix system includes the following: • The ControlLogix controller, available in different combinations of user memory • Studio 5000 environment • 1756 ControlLogix I/O modules that reside in a 1756 chassis • Separate communication modules for network communication Feature 1756-L71, 1756-L72, 1756-L73, 1756-L74, 1756-L75 1756-L81E, 1756-L82E, 1756-L83E, 1756-L84E, 1756-L85E Controller tasks • 32 tasks • 1000 programs/task(2) • Event tasks: all event triggers • 32 tasks • 1000 programs/task • Event tasks: all event triggers Built-in communication ports 1 port USB Client • 1 port USB client • Single-port EtherNet/IP Communication options • • • • • • • • • • • • • • Controller device 500 connections N/A Node capacity N/A • • • • • Network connections, per network module(1) • • • • • • N/A(4) Controller redundancy Full support Future Integrated motion • EtherNet/IP connection • SERCOS interface • Analog options (encoder input, LDT input, SSI input) • EtherNet/IP connection Programming languages • • • • • • • • EtherNet/IP ControlNet DeviceNet Data Highway Plus Remote I/O SynchLink Third-party process and device networks 256 EtherNet/IP; 128 TCP (1756-EN2x, 1756-ENxT(R)) 128 EtherNet/IP; 64 TCP (1756-ENBT) 128 ControlNet (1756-CN2/B) 100 ControlNet (1756-CN2/A) 64 EtherNet/IP; 32 TCP (5069-AENTR) 40 ControlNet (1756-CNB) Relay ladder Structured text Function block Sequential function chart (SFC) EtherNet/IP ControlNet DeviceNet Data Highway Plus Remote I/O SynchLink Third-party process and device networks 1756-L81E: 60 EtherNet/IP nodes(3) 1756-L82E: 80 EtherNet/IP nodes(3) 1756-L83E: 100 EtherNet/IP nodes(3) 1756-L84E: 150 EtherNet/IP nodes(3) 1756-L85E: 300 EtherNet/IP nodes(3) Relay ladder Structured text Function block Sequential function chart (SFC) (1) For the ControlLogix 5580 controllers, the total number of devices cannot exceed the total number of devices that the controller supports. The number of connections per network module shown is the maximum designed capacity of the modules. The device data size and requested data rate determines the actual device capacity. (2) Studio 5000, version 23 and earlier, is limited to 100 Programs/Task. (3) This value is the maximum number of EtherNet/IP nodes that the controller supports. Use the Integrated Architecture Builder design tool to lay out and validate your system design and additional node options. For further information on nodes on an EtherNet/IP network, see the ControlLogix 5580 Controllers User Manual, publication 1756-UM543. (4) This value is determined by the node capacity for the ControlLogix 5580 controllers.See the node capacity feature for more information. Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 25 Select a ControlLogix System ControlLogix-XT Controllers The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers, with an extended temperature range, and have the same features as the ControlLogix L7 controllers. The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh, corrosive environments: • While the standard ControlLogix system can withstand temperatures from 0…60 °C (33…140 °F), the ControlLogix-XT system can withstand temperatures from -25…70 °C (-13…158 °F). Redundant ControlLogix Controllers The ControlLogix controller supports controller redundancy. In a redundant controller system, you need these components: • Two 1756 chassis each with the following the same: – Number of slots – Modules in the same slots – Redundancy firmware revisions in each module – Two additional ControlNet nodes(1) outside the redundant chassis pair. • One 1756-RM2 or 1756-RM2XT module per chassis that supports the following: – One or two ControlLogix or ControlLogix-XT controllers of the same family – As many as seven ControlNet or EtherNet/IP communication modules in any combination • One or two 1756-RMCx cables For additional redundancy rules and restrictions, see the ControlLogix Enhanced Redundancy System User Manual, publication 1756-UM535. (1) For a ControlNet I/O drop, two more ControlNet nodes are required outside the redundancy chassis pair. Not applicable with Ethernet I/O control. 26 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System GuardLogix Controllers A GuardLogix controller is a ControlLogix controller that also provides safety control. Application Description SIL 1, 2, 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508, and applications up to and including PLe/Cat.4 according to ISO 13849-1. For more information, see the following: • GuardLogix 5570 Controllers User Manual, publication 1756-UM022. Provides information on how to install, configure, and operate GuardLogix 5570 Controllers in Studio 5000, Version 21 or later projects. • GuardLogix 5570 Controller Systems Safety Reference Manual, publication 1756-RM099. Provides information on how to meet safety application requirements for GuardLogix 5570 Controllers in Studio 5000, Version 21 or later projects. The GuardLogix system is a dual controller solution. You must use a primary controller and a safety partner to achieve SIL 3/PLe/Cat. 4. Primary Controller Safety Partner 1756-L71S, 1756-L72S, 1756-L73S 1756-L7SP 1756-L73SXT 1756-L7SPXT During development, safety and standard have the same rules, multiple programmers, online editing, and forcing are all allowed. Once the project is tested and ready for final validation, you set the Safety Task to a SIL 3 integrity level, which the GuardLogix controller enforces. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the GuardLogix controller, all functions operate like a regular Logix controller. Use Guard I/O™ modules for field device connectivity on Ethernet or DeviceNet networks, and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks. Multiple GuardLogix controllers can share safety data for zone to zone interlocking, or one GuardLogix controller can use remote distributed safety I/O between different cells/ areas. The GuardLogix controller has the standard features of a ControlLogix controller and these safety-related features. Feature 1756-LSP, 1756-L71S, 1756-L72S, 1756-L73S, 1756-L7SP, 1756-L73SXT, 1756-L7SPXT Safety communication options Standard and safety • EtherNet/IP • ControlNet • DeviceNet Network connections, per network module • • • • Controller redundancy Not supported Safety Task Programming languages Relay ladder 256 EtherNet/IP; 128 TCP (1756-EN2x, 1756-EN3x) 128 EtherNet/IP; 64 TCP (1756-ENBT) 128 ControlNet (1756-CN2/B, 1756-CN2R/B) 64 DeviceNet (1756-DNB) Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 27 Select a ControlLogix System Armor ControlLogix and Armor GuardLogix Controllers The Armor ControlLogix controller, extends the standard ControlLogix platform to the On-Machine space. The Armor GuardLogix controller delivers safety control up to SIL 3, PLe, CAT 4. Both controllers have the equivalent of two embedded 1756-EN3TR modules, which offer dual independent Ethernet ports that support a DLR network topology. Feature 1756-L72EROM 1756-L72EROMS Communication options Standard • EtherNet/IP Standard and safety • EtherNet/IP Controller redundancy Not supported Programming languages • • • • 28 Relay ladder Structured Text Function block Sequential function chart • Relay ladder Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Accessories—Controllers Memory Cards Memory cards offer nonvolatile memory to store a user program and tag data on a controller. The ControlLogix L7 and GuardLogix L7 controllers ship with 1784-SD1 Secure Digital (SD) card installed. The memory card installs in a socket on the controller. Through the Logix Designer application, you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup. Attribute 1784-SD1 1784-SD2 Memory 1 GB 2 GB Supported controllers 1756 ControlLogix L7 and 1756 GuardLogix L7 Weight, approx 1.76 g (0.062 oz) 1756 Energy Storage Modules Important: Energy storage modules apply to only ControlLogix 5570 controllers. Instead of a battery, the ControlLogix and GuardLogix controllers ship with a 1756-ESMCAP energy storage module (ESM) installed. Cat No. Description 1756-ESMCAP Capacitor-based ESM included with the controller. 1756-ESMNSE ESM without WallClockTime back-up power. Additionally, you can use this ESM only with a 1756-L73 (8 MB) or smaller memory-sized controller. Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 μJ or less before transporting it into or out of your application. 1756-ESMNRM ESM that secures the controller by permanently preventing the USB connection and SD card use. This ESM provides your application an enhanced degree of security. The ControlLogix-XT extreme temperature controller ships with a 1756-ESMNCAPXT energy storage module installed. Cat No. Description 1756-ESMCAPXT Capacitor-based ESM included with the controller. 1756-ESMNSEXT ESM without WallClockTime back-up power. Additionally, you can use this ESM only with a1756-L73XT (8 MB) or smaller memory-sized controller. Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 μJ or less before transporting it into or out of your application. 1756-ESMNRMXT ESM that secures the controller by permanently preventing the USB connection and SD card use. This ESM provides your application an enhanced degree of security. The 1756-L7SP safety partner for a GuardLogix system has the following modules available. Cat No. Description 1756-SPESMNSE Capacitor-based ESM for a GuardLogix safety partner. 1756-SPESMNRM ESM for a GuardLogix safety partner that secures the safety partner by permanently preventing the USB connection and SD card use. Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 29 Select a ControlLogix System ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 I/O chassis. Place any module into any slot. The backplane provides a high-speed communication path between modules. The chassis are designed for horizontal-only, back-panel mounting. The chassis are available in these options: • Standard chassis • ControlLogix-XT chassis For detailed specifications, see the 1756 ControlLogix Chassis Specifications Technical Data, publication 1756-TD006. Standard Chassis The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis. Cat. No. Description Slots 1756-A4 Standard chassis 4 1756-A7 7 1756-A10 10 1756-A13 13 1756-A17 17 ControlLogix-XT Chassis The ControlLogix-XT chassis support extreme temperature environments. Cat. No. Description Slots Temperature Range 1756-A7XT ControlLogix-XT chassis 7 -25…70 °C (-13…158 °F) Accessories - Chassis Use a slot filler module to fill empty slots. Cat. No. Description 1756-N2 Slot filler module for empty slots in standard ControlLogix chassis 1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis 30 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System ControlLogix Power Supplies ControlLogix power supplies are used with the 1756 chassis to provide 1.2V, 3.3V, 5V, and 24V DC power directly to the chassis backplane. Select from these configurations: • Standard power supplies • ControlLogix-XT power supplies • Redundant power supplies For detailed specifications, see the 1756 ControlLogix Power Supplies Specifications Technical Data, publication 1756-TD005. Standard Power Supplies You mount a standard power supply directly on the left end of the chassis, where it plugs directly into the backplane. Cat. No. Description Voltage Category Operating Voltage Range Chassis 1756-PA72 Standard AC power supply 120V/220V AC 85…265V AC Standard, series A, and series B 120V/220V AC 85…265V AC Standard, series B 24V DC 18…32V DC Standard, series A, and series B 1756-PB75 24V DC 18…32V DC Standard, series B 1756-PC75 48V DC 30…60V DC Standard, series B 1756-PH75 125V DC 90…143V DC Standard, series B 1756-PA75 1756-PB72 Standard DC power supply ControlLogix-XT Power Supplies The ControlLogix-XT power supplies support extreme temperature environments. Cat. No. Description Voltage Category Operating Voltage Range Chassis 1756-PAXT ControlLogix-XT AC power supply 85…265V AC 120/240V AC XT 1756-PBXT ControlLogix-XT DC power supply 24V DC 18…32V DC XT Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 31 Select a ControlLogix System Redundant Power Supplies A redundant power supply system provides extra uptime protection for chassis that are used in critical applications. The redundant power supplies funnel power through the chassis adapter to the ControlLogix series B chassis backplane. To build a redundant power supply system, you need the following components. Cat. No. Amount Description Voltage Category Operating Voltage Range Chassis 1756-PAR2 Kit Bundled system contains: – Two1756-PA75R power supplies – Two 1756-CPR2 cables – One 1756-PSCA2 chassis adapter 110V AC N/A Standard, series B 1756-PAR2XT Kit Bundled system contains: – Two1756-PAXTR power supplies – Two 1756-CPR2 cables – One 1756-PSCA2 chassis adapter 110V AC N/A 1756-PBR2 Kit Bundled system contains: – Two 1756-PB75R power supples – Two 1756-CPR2 cables – One 1756-PSCA2 chassis adapter 24V DC N/A 1756-PBR2XT Kit Bundled system contains: – Two 1756-PBXTR power supples – Two 1756-CPR2 cables – One 1756-PSCA2 chassis adapter 24V DC N/A 1756-PA75R/A or 1756-PAXTR 2 Redundant AC power supply 120V/220V AC 85…256V AC 1756-PB75R/A or 1756-PBXTR 2 Redundant DC power supply 24V DC 19.2…32V DC N/A 2 Redundant power supply cable: Connector angle = straight, length = 0.91 m (3 ft) Connector angle = down, length = 0.91 m (3 ft) Connector angle = up, length = 0.91 m (3 ft) N/A 1756-CPR2 or 1756-CPR2D or 1756-CPR2U 1756-PSCA2 or 1756-PSCA2XT 1 Redundant power supply chassis adapter N/A (user-supplied) 2 Annunciator wiring(1) (Maximum length = 10 m [32.8 ft]) (1) Optional user-supplied annunciator wiring can be connected to the solid-state relay input for status and troubleshooting purposes. 32 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Select a ControlLogix System Notes: Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 33 Select a ControlLogix System Notes: 34 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 ControlLogix System Selection Guide 35 Rockwell Automation Publication 1756-SG001U-EN-P - February 2016 Rockwell Automation Support Use the following resources to access support information. Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. www.rockwellautomation.com/knowledgebase Local Technical Support Phone Numbers Locate the phone number for your country. www.rockwellautomation.com/global/support/get-supportnow.page Direct Dial Codes Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. www.rockwellautomation.com/global/support/direct-dial.page Literature Library Installation Instructions, Manuals, Brochures, and Technical Data. www.rockwellautomation.com/literature Product Compatibility and Download Center (PCDC) Get help determining how products interact, check features and capabilities, and find associated firmware. www.rockwellautomation.com/global/support/pcdc.page Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/ documents/du/ra-du002_-en-e.pdf. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainabilityethics/product-environmental-compliance.page. Allen-Bradley, Armor, ArmorBlock, Armor GuardLogix, ArmorPOINT, ArmorStart, ArmorStratix, CompactLogix, ControlLogix, ControlLogix-XT, Data Highway Plus, DH+, Dynamix, Encompass, FactoryTalk, FLEX Ex, FLEX I/O, Guard I/O, GuardLogix, Kinetix, LISTEN. THINK. SOLVE., Logix5000, On-Machine, PanelView, POINT Guard I/O, POINT I/O, PowerFlex, PowerMonitor, Rockwell Automation, Rockwell Software, RSFieldbus, RSLogix 5000, Stratix 5100, Stratix 5400, Stratix 5700, Studio 5000, Studio 5000 Automation Engineering & Design Environment, and SynchLink are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. ControlNet, DeviceNet, and EtherNet/IP are trademarks of the ODVA. Publication 1756-SG001U-EN-P - February 2016 Supersedes Publication 1756-SG001T-EN-P - October 2015 Copyright © 2016 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement