Important Things to Know
Important Things to Know... ..................2
Parts Identification...........................4
Preparation for Use.........................5
How to Operate the
Thermometer...................................6
Memory Mode..................................8
Cleaning and Care..........................10
Troubleshooting and Special
Indications.....................................11
Specifications ...............................1 2
Limited Warranty...........................13
FCC Statement..............................14
INSTRUCTION
MANUAL
Quick Start
1. Install batteries into the thermometer making
sure the polarity is correct.
2. Press and release the POWER button. Unit
will beep once. Wait until it beeps again
twice and only °F shows in the display.
Do not place the probe to the temple before the
2 beeps or while the hour glass is still displayed
3. Place and hold the thermometer probe
firmly to the skin at the temple, wait several
seconds for the device to beep once more.
Once you place the probe to the temple, there is
no need to press the POWER button again. Doing
so will turn the unit off.
Digital Temple
Thermometer
4. Read the temperature on the display.
Model KD-2220
POWER SOURCE
SIZE AAA 1.5V x 2 (included)
0197
IMPORTANT !
Read instruction manual
before using themometer
WARRANTY:
ONE YEAR FROM THE DATE OF PURCHASE
(excluding batteries)
1
Important Things to Know
1. Use the thermometer to measure your
temple temperature only, the area between the outer corner of the eye and
the hairline, over the temporal artery.
2. Do not place the thermometer on
scarred tissue, open sores or
abrasions.
3. Using drug therapies can raise skin
temperature, which may lead to
incorrect measurements.
4. Do not dismantle the unit except to
replace the batteries.
5. Children should not use the thermometer without adult supervision.
6. Do not drop or expose thermometer
to electric shock as this may adversely
affect its performance.
7. The thermometer is not waterproof.
Do not immerse it in water or liquid of
any kind.
8. To ensure correct readings, wait at
least 2 minutes between continuous
measurements for the thermometer
to return to room temperature.
9. Do not use the thermometer around
flammable materials.
10. Stop using the thermometer if
malfunctions appear or if it operates
abnormally.
11. Clean the thermometer probe after
each measurement.
12. Do not take a measurement if the
temple area has just been exposed
to direct sunlight, fireplace heat or air
conditioner flow, as this may lead to
incorrect readings.
13. If thermometer has been kept or
stored in a cold temperature, please
wait at least 1 hour for it to return to
room temperature before measuring.
14. Performance of the thermometer may
be degraded if the unit is operated or
stored outside the stated temperature
or humidity ranges, or if the patient’s
temperature is below room temp.
15. Body temperature, like blood pressure,
varies from person to person. During
the day, it can range from 95.9°F to
100.0°F (35.5 to 37.8°C). For some
people there can be a difference between their temple and body temp.
We recommend learning what your
normal temple temperature is while
healthy so you can detect an elevated
one when you become ill. For
accuracy, be sure to measure the
same area of the temple each time.
16. Avoid taking a measurement for at
least 30 minutes after physical
exercise, bathing or eating.
17. Make sure the temporal area is dry
and clean of sweat, make-up, etc.
18. The device is intended for consumer
use only.
19. Calibration is recommended every
two years.
2
3
Probe
POWER
Button
3. Install 2 new "AAA" batteries into the
battery compartment matching
correct polarities.
4. Replace the battery cover securely.
Battery Cover
What are normal temperature values?
Human body temperature varies from
person to person. Also, a person’s
body temperature can fluctuate
throughout the day. Therfore, it is very
important to know your normal body
temperature range. Therefore, we
recommend you measure yourself
when healthy to establish referenced
temperatures which will make you feel
more confident of the measured
temperature readings when ill.
Preparation for Use
Installing/Replacing the Battery:
1. Pull the battery cover off in the
direction shown.
2.Prior to installing new batteries you
must clean the metal contact ends of
the batteries and the metal springs
and contacts for the batteries in the
battery compartment.
4
3
1
1. Press the POWER button to turn on
the unit. A beep sound follows.
7. Once the measurement is done, you will
hear 2 beeps indicating the reading has
been recorded and it is ready to take the
next measurement. However, we do not
recommend consecutive measurements.
2. The last memory is displayed.
2
LCD Display
How to Operate the
thermometer
How to Operate the
thermometer
Preparation for Use
Parts Identification
Ready for next
measurement
Waiting
Last memory
3. You will hear 2 beeps with the
measuring scale shown as Figure 4.
8. Turn off the unit by pressing the
POWER button, or the unit will
automatically turn off (and beep)
after 1 minute of inactivity.
WARNING:
1. Do not dispose of batteries in regular
household trash, refer to your local
disposal laws and manage as
hazardous waste.
2. Do not recharge, put in backwards,
disassemble or dispose of batteries
in fire. Doing so may result in
explosion, leakage and injury.
CAUTION:
1. Replace both batteries at the same
time. Do not mix old and new ones.
2. Never mix alkaline, standard (carbonzinc) or rechargeable (nickel-cadmium)
batteries.
5
Ready to measure
Waiting
4. Put the thermometer on the temple.
It will beep one time to present
measurement completion.
5. The display will light according to the
reading. Please refer to table below.
6. If the temperature reading is over
99.5°F(37.5°C), eight consecutive
beeps will be heard to indicate fever
alarm.
Measurement
Temperature in °F
Measurement
Temperature in °C
Back Light Color
UP TO 98.8
98.9 - 99.4
99.5 AND UP
UP TO 37.1
37.2 - 37.4
37.5 AND UP
Green
Yellow
Red
6
Switching between Fahrenheit and
Centigrade Scale:
You can switch between °F and °C scales.
Within 3 seconds after turning on the
device, again press and hold the
POWER button. The display will show
“CH” with “°F” or “°C”.
°F
°C
Mode
7
Mode
Memory Mode
Memory Mode
Cleaning and Care
Deleting Memories:
Recalling Memories:
1. Begin with the unit turned off.
2. Press the POWER button and hold for
approximately 3 seconds until the most
recent memory is shown, then release.
3. Press and release the button again and
again to scroll through the remaining
previous memories.
Do not drop the unit or
expose to heavy or electric
shock as this will adversely
affect it’s performance.
Unit is not shock proof.
If you choose to delete memories on the
thermometer, this may be done after
step 2 or 3 of Recalling Memories.
It is not necessary to delete memories, it
is simply an option. Oldest memories will
automatically be deleted as you take new
measurements. Removing the batteries
will also delete all memories from the unit.
Wipe the tip and probe with
a cotton swab moistened
with rubbing alcohol, or use
an alcohol wipe, before and
after each use. Then wait
at least 2 minutes to allow
the unit to readjust to room
temperature before taking
another measurement.
~ NOTE ~
ALL memories will be deleted in this process,
you cannot delete just one single memory
1. As you are scrolling through and viewing
stored memories, at any time you may
press and hold the POWER button for
3 seconds until dEL displays - then
release the button.
If necessary, use only a
soft cloth to clean the body
of the thermometer. Avoid
using thinner, benzene or
other harsh cleaners.
Do not use an abrasive
cleanser and NEVER
submerge the thermometer
in water or any other liquid.
Etc...
4. When you are finished viewing stored
memories, discontinue pressing the
button. After a short pause, you will
hear 2 beeps indicating the unit is
ready to take a new measurement.
Ready to
measure
8
2. While dEL is still displayed, press and
release* the POWER button once more
to finish the delete process. OFF will
show on the display and all stored
memories are now deleted.
*If you do not press and release the POWER
button in this step, the thermometer will
return to recalling memories
9
Z
ZZ
Remove the batteries if the
thermometer will not be
used for a long period of
time.
Do not expose the unit to
extreme temperatures (cold
or hot), high humidity or
direct sunlight. Thermometer
should be stored at normal
room temperature.
10
Troubleshooting
Memory Mode
Message
Instruction
The temperature
measured was higher
than the specified measuring range. Wait 2
minutes and try again.
The ambient (room)
temperature was
outside the operating
range. Keep it at room
temperature (approx.
60~104°F) fo r 30
minutes before using.
Poor contact caused
the thermometer t o
stop measuring. The
thermometer will
power off
automatically. Please
measure again.
The thermometer has
malfunctioned. Please
contact distributor
Indicates a low battery
condition. Replace with
2 new “AAA” batteries
as soon as possible.
Replace with 2 new
“AAA” batteries