HP ProCurve Series 2600 Installation And Getting Started Manual

Add to my manuals
116 Pages

advertisement

HP ProCurve Series 2600 Installation And Getting Started Manual | Manualzz
Installation and
Getting Started Guide
ProCurve Series
2600 Switches
PoE
Power over Ethernet Devices
www.procurve.com
ProCurve Series 2600 Switches
Installation and Getting Started Guide
© Copyright 2001, 2005 Hewlett-Packard Development
Company, L.P. The information contained herein is subject to
change without notice.
This document contains proprietary information, which is
protected by copyright. No part of this document may be
photocopied, reproduced, or translation into another language
without the prior written consent of Hewlett-Packard.
Publication Number
Applicable Products
(J8164A)
(J8165A)
(J8762A)
(J8168A)
(J8169A)
(J4900B)
(J4899B)
Trademark Credits
Windows® is a US registered trademark of Microsoft
Corporation.
Hewlett-Packard Company
8000 Foothills Boulevard, m/s 5552
Roseville, California 95747-5552
http://www.procurve.com
HEWLETT-PACKARD COMPANY MAKES NO WARRANTY
OF ANY KIND WITH REGARD TO THIS MATERIAL,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be
liable for errors contained herein or for incidental or consequential
damages in connection with the furnishing, performance, or use
of this material.
The only warranties for HP products and services are set forth in
the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an
additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
5991-2165
September 2005
ProCurve Switch 2626-PWR
ProCurve Switch 2650-PWR
ProCurve Switch 2600-8-PWR with Gigabit Uplink
ProCurve 600 Redundant and External
Power Supply
ProCurve 610 External Power Supply
ProCurve Switch 2626
ProCurve Switch 2650
Disclaimer
Hewlett-Packard assumes no responsibility for the use or
reliability of its software on equipment that is not furnished by
Hewlett-Packard.
Warranty
See the Customer Support/Warranty booklet included with the
product.
A copy of the specific warranty terms applicable to your HewlettPackard products and replacement parts can be obtained from your
HP Sales and Service Office or authorized dealer.
Contents
1 Introducing the Switch
Front of the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Multiple-Display Port LEDs - Port LED View or
LED Mode Select Button and Indicator LEDs . . . . . . . . . . . . . . . . 1-7
Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Clear Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Back of the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Switch Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
2 Installing the Switch
Included Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Installation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
1. Prepare the Installation Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2. Installing or Removing mini-GBICs . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
3. Verify the Switch Passes Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
LED Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
4. Mount the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack or Cabinet Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack Mounting the 2626-PWR and 2650-PWR switches . . . . . . .
Rack Mounting the Non-PWR Switches and the 2600-8-PWR Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flat Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall mounting the Series 2600 Non-PWR Switches . . . . . . . . . .
Wall mounting the Series 2600-8-PWR Switch . . . . . . . . . . . . . . .
Horizontal Surface Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-11
2-11
2-12
2-14
2-16
2-17
2-18
2-19
5. Connect the Switch to a Power Source . . . . . . . . . . . . . . . . . . . . . . 2-19
iii
6. Connect the Network Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Using the RJ-45 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Connecting Cables to mini-GBICs . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
7. (Optional) Connect a Redundant Power Supply to a Series 2600-PWR Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RPS/EPS Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Characteristics of the 600 RPS/EPS (J8168A) . . . . . .
600 RPS/EPS LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
610 EPS LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Characteristics of the 610 EPS (J8169A) . . . . . . . . . .
2-21
2-22
2-22
2-23
2-27
2-27
8. (Optional) Connect a Console to the Switch . . . . . . . . . . . . . . . . . . 2-30
Terminal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30
Direct Console Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Sample Network Topologies for
Non-PWR Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
As a Desktop Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
As a Segment Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Connecting to a Backbone Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Sample Network Topologies for PWR Switches . . . . . . . . . . . . . . . . . . . . 2-36
As a Desktop Switch Implementing PoE . . . . . . . . . . . . . . . . . . . . . . . 2-36
As a Segment Switch Implementing PoE . . . . . . . . . . . . . . . . . . . . . . . 2-37
Stacking the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
3 Configuring the Switch
Recommended Minimal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Using the Console Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Where to Go From Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Using the IP Address for Remote Switch Management . . . . . . . . . . . . . . . . 3-5
Starting a Telnet Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Starting a Web Browser Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
4 Troubleshooting
Basic Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Diagnosing with the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Proactive Networking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Hardware Diagnostic Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
iv
Testing the Switch by Resetting It . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Checking the Switch LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Checking Console Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Testing Twisted-Pair Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Testing Switch-to-Device Network Communications . . . . . . . . . . . . 4-10
Testing End-to-End Network Communications . . . . . . . . . . . . . . . . . 4-10
Restoring the Factory Default Configuration . . . . . . . . . . . . . . . . . . . . . . . 4-11
Downloading New Switch Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
HP Customer Support Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Before Calling Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
A Switch Specifications
Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Acoustic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Cable Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Lasers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
B Switch Ports and Network Cables
Switch Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Twisted-Pair Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Fiber-Optic Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
Mode Conditioning Patch Cord for Gigabit-LX . . . . . . . . . . . . . . . . . . . . . B-3
Installing the Patch Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
Twisted-Pair Cable/Connector Pin-Outs . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Straight-through Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connections . . . . . . . . . . . . . . . . . . . . B-7
Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Crossover Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connection . . . . . . . . . . . . . . . . . . . . . B-8
Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
v
Straight-Through Twisted-Pair Cable for
1000 Mbps Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
C Safety and EMC Regulatory Statements
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Informations concernant la sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Hinweise zur Sicherheit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3
Considerazioni sulla sicurezza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4
Consideraciones sobre seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5
Safety Information (Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6
Safety Information (China) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7
EMC Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
U.S.A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Australia/New Zealand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9
Taiwan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9
European Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-10
Waste Electrical and Electronic Equipment (WEEE) Statements . . . . . C-12
Index
vi
1
Introducing the Switch
ProCurve Switch 2650 (J4899B)
ProCurve Switch 2626 (J4900B)
ProCurve Switch 2650-PWR (J8165A)
hp procurve
switch 2650-PWR
J8165A
1
1
3
5
7
9
11
2
4
6
8
10
12
11
13
13
15
17
19
21
23
14
16
18
20
22
24
Link|Mode
23
25
25
27
29
31
33
35
26
28
30
32
34
36
35
37
37
39
41
43
45
47
38
40
42
44
46
48
47
Gig-T
Ports
PoE
Status
RPS
Power
Fault
EPS
Fan
Act
LED
Mode
49
FDx
M
50
M
Spd
Test
PoE
Reset
Clear
MiniGBIC
Ports
2
Spd mode:
off = 10 Mbps,
flash = 100 Mbps,
on = 1000 Mbps
12
14
PoE-Ready 10/100Base-TX Ports (1 - 48)
26
24
36
38
48
(all 10/100Base-TX ports are HP Auto-MDIX, Gig-T ports are IEEE Auto MDI/MDI-X)
! Use only one (T or M) for each Gigabit port
ProCurve Switch 2626-PWR (J8164A)
Link|Mode
hp procurve
switch 2626-PWR
J8164A
1
1
3
5
7
9
11
2
4
6
8
10
12
11
13
13
15
17
19
21
23
14
16
18
20
22
24
23
Gig-T
Ports
PoE
Status
RPS
Power
Fault
EPS
Fan
LED
Mode
Act
25
FDx
M
26
Spd
Test
PoE
Reset
Clear
M
MiniGBIC
Ports
Spd mode:
off = 10 Mbps,
flash = 100 Mbps,
2
on = 1000 Mbps
12
PoE-Ready 10/100Base-TX Ports (1 - 24)
14
(all 10/100Base-TX ports are HP Auto-MDIX, Gig-T ports are IEEE Auto MDI/MDI-X)
24
!
Use only one (T or M) for each Gigabit port
ProCurve Switch 2600-8-PWR with Gigabit Uplink (J8762A)
*Spd mode:
ProCurve
Switch 2600-PWR
J8762A
Status
RPS
Power
Fault
EPS
off = 10 Mbps,
flash = 100 Mbps,
on = 1000 Mbps
Dual-Personality Port:
10/100/1000-T (T) or Mini-GBIC (M)
PoE-Integrated 10/100-TX Ports (1 - 8) — (Ports are HP Auto-MDIX)
(Port 9T is IEEE Auto MDI/MDIX)
PoE
LED
Mode
Link
Act
FDx
1
Mode
2
3
4
Link
5
Mode
6
7
8
Link
9T
9M
Mode
Link
*
Fan
Spd
Test
PoE
Reset
Clear
Console
Mode
! Use only one (T or M) for Port 9
Throughout this manual, these switches will be referred to as the Series 2600
Switches and the Series 2600-PWR Switches.
1-1
Introducing the Switch
The ProCurve Series 2600 Switches are multiport switches that can be used
to build high-performance switched workgroup networks. These switches are
store-and-forward devices that offer low latency for high-speed networking.
The 2600-PWR Switches also support Redundant Power Supply and Power
over Ethernet (PoE) technologies.
Introducing the Switch
Introducing the Switch
■
The Switch 2650 and 2650-PWR, has 48 auto-sensing 10/100Base-TX RJ­
45 ports with two dual-personality Gigabit Uplink ports.
■
The Switch 2626 and 2626-PWR, has 24 auto-sensing 10/100Base-TX RJ­
45 ports with two dual-personality Gigabit Uplink ports.
■
The Switch 2600-8-PWR, has 8 auto-sensing 10/100Base-TX RJ-45 ports
with one dual-personality Gigabit Uplink port.
The dual-personality ports are either auto-sensing 10/100/1000Base-T RJ-45,
or mini-GBIC (Small Form Factor Pluggable (SFP) ports in an Ethernet
application).
The Series 2600-PWR Switches incorporate two additional features. These
switches offer two types of power, one for switch AC operating power, and
the other for Power over Ethernet (PoE) power:
■
Power-over-Ethernet or PoE power - PoE technology allows IP tele­
phones, wireless LAN Access Points and other appliances to receive
power as well as data over existing LAN cabling, without needing to
modify the existing Ethernet infrastructure. The Series 2600-PWR
Switches are designed with an internal PoE power supply capable of
providing 406 watts of PoE power (126 watts on the 2600-8-PWR). All of
the Switch 2600-PWR ports can provide up to 15.4 watts of PoE power to
connected devices. For further information regarding PoE power, see the
PoE Planning and Implementation Guide which is on the documentation
CD that came with the switch.
■
Redundant and External Power Supply Support - The Series 2600­
PWR Switches can be connected to a ProCurve 600 Redundant and
External Power Supply (J8168A), hereafter referred to as the 600 RPS/
EPS or a ProCurve 610 External Power Supply, hereafter referred to as
the 610 EPS, and receive redundant power from that unit. As an RPS unit,
the 600 RPS/EPS will provide all the AC power necessary to keep the
switch running should the switch internal AC power supply fail.
As an EPS unit, the 600 RPS/EPS and the 610 EPS can supply up to 408
watts of PoE power to the switch if the internal PoE power supply of the
switch should fail. When used with the Switch 2650-PWR, the additional
EPS power can provide up to 15.4 watts per port for 48 ports. For further
information regarding the 600 RPS/EPS or the 610 EPS PoE capabilities,
see the PoE Planning and Implementation Guide, which is on the
documentation CD that came with the switch.
With these switches you can directly connect computers, printers, and servers
to provide dedicated bandwidth to those devices, and you can build a switched
network infrastructure by connecting the switch to hubs, other switches, or
routers. In addition, the Series 2600 Switches offer full network management
capabilities.
1-2
Introducing the Switch
Front of the Switch
Power
and Fault
LEDs
Self Test and Fan
Status LEDs
hp procurve
switch 2650-PWR
J8165A
1
10/100Base-TX RJ-45 ports1
RPS, EPS, Fan and
Test Status LEDs
Power
and Fault
LEDs
ProCurve Switch 2650
Switch port LEDs
Port LED View select
button and indicator LEDs
Reset and Clear
buttons
1
3
5
7
9
11
2
4
6
8
10
12
11
Dual-personality ports
(1000Base-T2 or mini-GBIC)
ProCurve Switch 2650-PWR
Switch port LEDs
13
13
15
17
19
21
23
14
16
18
20
22
24
Link|Mode
23
25
Introducing the Switch
Front of the Switch
25
27
29
31
33
35
26
28
30
32
34
36
35
37
37
39
41
43
45
47
38
40
42
44
46
48
47
Gig-T
Ports
PoE
Status
RPS
EPS
Power
Fan
Fault
LED
Mode
Act
49
FDx
PoE
Clear
Spd mode:
Power
and Fault
LEDs
off = 10 Mbps,
flash = 100 Mbps,
Fault
EPS
Fan
12
14
PoE-Ready 10/100Base-TX Ports (1 - 48)
LED Mode select button
and indicator LEDs
24
26
36
38
(all 10/100Base-TX ports are HP Auto-MDIX, Gig-T ports are IEEE Auto MDI/MDI-X)
ProCurve Switch 2600-8-PWR
Console Port
*Spd mode:
off = 10 Mbps,
flash = 100 Mbps,
on = 1000 Mbps
Dual-Personality Port:
10/100/1000-T (T) or Mini-GBIC (M)
PoE-Integrated 10/100-TX Ports (1 - 8) — (Ports are HP Auto-MDIX)
Link
Act
1
Mode
2
3
4
Link
5
FDx
Spd
! Use only one (T or M) for each Gigabit port
Dual-personality ports
(1000Base-T2 or mini-GBIC)
10/100Base-TX RJ-45 ports1
(Port 9T is IEEE Auto MDI/MDIX)
PoE
LED
Mode
48
Switch port LEDs
Switch 2600-PWR
Power
on = 1000 Mbps
RPS, EPS, Fan and
Test Status LEDs
ProCurve
RPS
M
MiniGBIC
Ports
2
Reset and Clear
buttons
J8762A
50
Spd
Test
Reset
Status
M
Mode
6
7
8
Link
9T
9M
Mode
Link
*
Test
PoE
Reset
Clear
Reset and Clear
buttons
Mode
Console
! Use only one (T or M) for Port 9
LED Mode select button
and indicator LEDs
10/100Base-TX RJ-45 ports1
Dual-personality port
(1000Base-T2 or mini-GBIC)
1 All 10/100Base-TX RJ-45 ports have the HP Auto MDIX feature.
2
10/100/1000Base-T ports have the IEEE Auto MDI/MDI-X feature.
1-3
Introducing the Switch
Front of the Switch
Introducing the Switch
Network Ports
■
8, 24, or 48 auto-sensing 10/100Base-TX ports.
All these ports have the “HP Auto MDIX” feature, which means that you
can use either straight-through or crossover twisted-pair cables to
connect any network devices to the switch.
■
Dual-personality ports. You can use either the 10/100/1000Base-T RJ-45
connector, or install a supported ProCurve mini-GBIC for fiber-optic
connections. The RJ-45 connectors support the IEEE Auto MDI/MDI-X
feature, which operates the same as the “HP Auto-MDIX” feature.
By default, the RJ-45 connectors are enabled. If a mini-GBIC is installed,
it is enabled and the associated RJ-45 connector is disabled and cannot
be used. If the mini-GBIC is removed, the associated RJ-45 port is
automatically re-enabled.
LEDs
On the Series 2600 Switches, there are three groupings of LEDs:
■
switch status LEDs (Table 1-1)
■
port LEDs (Table 1-2)
■
Port LED View (non-PWR switches) and LED Mode (PWR switches)
indicator LEDs (near the selector button) (Table 1-3)
Table 1-1.
1-4
Switch Status LEDs
Switch LEDs
State
Meaning
Power
(green)
On
The switch is receiving power.
Off
The switch is NOT receiving power. (Unless and RPS is connected to the
switch. If the switch looses power and the RPS is actively powering the
switch, the Power LED will be off and the switch will still have power and
all other LEDs will be functional.)
Fault
(orange)
Off
The normal state; indicates there are no fault conditions on the switch.
Blinking1
A fault has occurred on the switch, one of the switch ports, the fan, or the
RPS or EPS operation of the switch. The Status LED for the component
with the fault will blink simultaneously.
On
On briefly after the switch is powered on or reset, at the beginning of
switch self test. If this LED is on for a prolonged time, the switch has
encountered a fatal hardware failure, or has failed its self test. See
chapter 4, “Troubleshooting” for more information.
Introducing the Switch
Front of the Switch
State
Meaning
Self Test
(green)
labeled “Test”
on the PWR
switches
Off
The normal operational state; the switch is not undergoing self test.
On
The switch self test and initialization are in progress after you have power
cycled or reset the switch. The switch is not operational until this LED
goes off. The Self Test LED also comes on briefly when you “hot swap” a
mini-GBIC into the switch; the mini-GBIC is tested when it is hot swapped.
Blinking1
A component of the switch has failed its self test. The status LED for that
component, for example an RJ-45 port, and the switch Fault LED will blink
simultaneously.
Fan Status
(green)
On
The cooling fan is operating normally.
Blinking1
The cooling fan has failed. The switch Fault LED will be blinking
simultaneously.
RPS Status 2
(green)
On
Normal operation. An 600 RPS/EPS unit is connected and operating
correctly. The 600 RPS/EPS could be powering the unit - see table below.
Blinking
The 600 RPS/EPS is connected but may be powering another switch or
the 600 RPS/EPS has experienced a fault.
Off
The 600 RPS/EPS is not connected or is not powered.
On
Connected to an External Power Supply, either an 600 RPS/EPS or an 610
EPS, and receiving PoE power.
Blinking
The External Power Supply has experienced a fault:
• PoE power is oversubscribed (not enough PoE power available).
• The software on the ProCurve Series 2600-PWR Switches may not
support the EPS function.
• There is a fan, overcurrent, power supply, or temp fault.
• The Switch detects the EPS is present but cannot communicate with it.
Check the Error Log on the switch for more information.
EPS Status 2
(green)
Off
The switch is not connected to an External Power Supply or the EPS cable
is connected but the External Power Supply is not powered up.
1 The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
2 ProCurve Series 2600-PWR Switches only.
See the ProCurve 600/610 External Power Supplies Installation and Getting
Started Guide for information on the LED behavior of the external power
supplies.
1-5
Introducing the Switch
Switch LEDs
Introducing the Switch
Front of the Switch
Introducing the Switch
Port LEDs
The port LEDs provide information about the individual switch ports.
Table 1-2.
Switch LEDs
Port LEDs
State
Meaning
Switch 2626 and Switch 2650
Port LEDs
(green – over­
laid with the
port number)
Displays port link information, network activity information, whether the port is
configured for full-duplex operation, or the speed of the connection depending on the
Port LED View selected. See “Port LED View Select Button and Indicator LEDs” on the
next page for more information.
Series 2600-PWR Switches
Link
(green - over­
laid with the
port number or
embedded
with the
connector)
On
Indicates the port is enabled and receiving a link beat signal (for the
twisted-pair ports), of a strong enough light level (for the fiber-optic ports)
from the connected device.
Off
One of these condition exists:
• no active network cable is connected to the port
• the port is not receiving link beat or sufficient light
• the port has been disabled through the switch console, the web browser
interface, ProCurve Manager, or other network management tool.
The port has failed self test. The switch Fault, and Self Test LEDs will flash
simultaneously.
Blinking1
Mode
Depending on the mode selected, displays the following: network activity information,
whether the port is configured for Full Duplex operation, maximum speed operation, or
whether network errors are occurring on the port. See “LED Mode Select Button and
Indicator LEDs:” below for more information.
All Series 2600 Switches 2
T/M
(green)
1
On
For the dual-personality ports, indicates the enabled port:
• if the “T” is on, the 10/100/1000Base-T RJ-45 port is enabled.
• if the “M” is on, the mini-GBIC port is enabled.
The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
For the 2600-8-PWR device, both connectors of the dual-personality port have Link and Mode LEDs. To
clearly indicate that the mini-GBIC/SFP port has taken control of port 9, when a mini-GBIC/SFP is fully
inserted into the garage, the Link LED will blink with a slow blink rate on the 9M port to indicate a status
change.
2
1-6
Introducing the Switch
Front of the Switch
To optimize the amount of information that can be displayed for each of the
switch ports in the limited space available, the Series 2600 Switches use
multiple-display LEDs for each port.
Switch 2626 and Switch 2650
For the non-PWR switches, there is a
single LED per port. The operation of
this LED is controlled by the Port LED
View select button, and the current
setting is indicated by the Port LED
View indicator LEDs near the button.
Press the button to step from one view
mode to the next. The default view is
Link (Lnk).
Port LED
(one for each port)
Port LED View select
button and indicator LEDs
For the PWR switches, there are two
LEDs per port. The Link status is
always shown by the Link LED. The
operation of the Mode LED is
controlled by the LED Mode select
button, and the current setting is indi­
cated by the LED Mode indicator LEDs
near the button. Press the button to
step from one view mode to the next.
The default view is Activity (Act).
Switch 2626-PWR and 2650-PWR
Mode LED
Link LED
(port number)
hp procurve
switch 2650-PWR
J8165A
1
1
3
5
7
9
2
4
6
8
10
Spd mode:
off = 10 Mbps,
PoE
Status
RPS
Power
Fault
EPS
Fan
LED
Mode
Act
FDx
Spd
Test
PoE
Reset
Clear
2
flash = 100 Mbps,
on = 1000
LED Mode select button
and indicator LEDs
Switch 2600-8-PWR
For the 2600-8-PWR switch,
the LEDs are embedded in
the port connector. The Link
and Mode LEDs operate the
same as the other PWR
switches (see above).
LED Mode select button
and indicator LEDs
Mode LED (Right LED)
Link LED
(Left LED)
1-7
Introducing the Switch
Multiple-Display Port LEDs - Port LED View or
LED Mode Select Button and Indicator LEDs
Introducing the Switch
Front of the Switch
Introducing the Switch
Table 1-3.
Switch LEDs
Multiple-Display Port LEDs
State
Meaning
Switch 2626 and Switch 2650
Port LED View
indicator LEDs
(4 green LEDs)
Lnk
Act
FDx
Spd
Indicates that the Port LEDs are displaying link information:
• if the Port LED is on, the port is enabled and receiving a link indication
from the connected device.
• if the Port LED is off, the port has no active network cable connected, or
is not receiving signal or sufficient light. Otherwise, the port may have
been disabled through the switch console or the web browser interface.
• if the Port LED is blinking1 simultaneously with the Fault LED, the
corresponding port has failed its self test.
Indicates the Port LEDs are displaying network activity information.
Indicates the Port LEDs are lit for ports that are in full-duplex mode.
Indicates the Port LEDs are displaying the connection speed at which each
port is operating:
• if the Port LED is off, the port is operating at 10 Mbps.
• if the Port LED is flashing, the port is operating at 100 Mbps.
• if the Port LED is on continuously, the port is operating at 1000 Mbps.
Series 2600-PWR Switches
LED Mode
indicator LEDs
(4 green LEDs)
Act
Indicates the Port Mode LEDs are displaying network activity information.
FDx
Indicates the Port Mode LEDs are lit for ports that are in full-duplex mode.
Spd
Indicates the Port Mode LEDs are displaying the connection speed at which
each port is operating:
• if the Port LED is off, the port is operating at 10 Mbps.
• if the Port LED is blinking2, the port is operating at 100 Mbps.
• if the Port LED is on continuously, the port is operating at 1000 Mbps.
Indicates the Port Mode LEDs are lit for ports that are providing PoE power
to the connected device.
PoE
1
2
1-8
The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
The blinking behavior is an on/off cycle once every 0.8 seconds, approximately.
Introducing the Switch
Front of the Switch
Reset Button
Clear Button
This button is used for these purposes:
■
Deleting Passwords - When pressed by itself for at least one second, the
button deletes any switch console access passwords that you may have
configured. Use this feature if you have misplaced the password and need
console access.
This button is provided for your convenience, but its presence means that
if you are concerned with the security of the switch configuration and
operation, you should make sure the switch is installed in a secure
location, such as a locked wiring closet.
■
Restoring Factory Default Configuration - When pressed with the
Reset button in a specific pattern, any configuration changes you may
have made through the switch console, the web browser interface, and
SNMP management are removed, and the factory default configuration is
restored to the switch. For the specific method to restore the factory
default configuration, see “Restoring the Factory Default Configuration”
on page 11, “Troubleshooting” of this manual.
1-9
Introducing the Switch
This button is used to reset the switch while it is powered on. This action clears
any temporary error conditions that may have occurred and executes the
switch self test.
Introducing the Switch
Back of the Switch
Introducing the Switch
Back of the Switch
ProCurve Switch 2626 and 2650 non-PWR
Cooling vent - make sure this is not
obstructed for proper switch operation
Console
Console Port
AC power connector
Cooling vent - make sure this is not
obstructed for proper switch operation
ProCurve Switch 2626-PWR and 2650-PWR
HP ProCurve
RPS Input
12V 7.5A
Console
Console Port
Line 50/60 Hz.
100-240 V~ 7.5 A
EPS Input
EPS Input
AC power connector
RPS Input
ProCurve Switch 2600-8-PWR
EPS Redundant Input
ProCurve RPS Input
!
Multiple power sources. Disconnect
both the AC power cord and the RPS cable
to completely remove power from the unit.
Line: 50/60 Hz
100 240 V~
3.3 A (3,3 A)
EPS Input
1-10
RPS Input
AC power
connector
Introducing the Switch
Switch Features
Console Port
Power Connector
The Series 2600 Switches do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-240 volts and either 50 or 60 Hz. There are
no voltage range settings required.
Switch Features
The features of the Series 2600 Switches include:
■
8, 24, or 48 auto-sensing 10/100Base-TX RJ-45 ports with HP Auto-MDIX.
■
dual-personality ports—either the auto sensing 10/100/1000Base-T RJ-45
or the mini-GBIC can be used for each port.
■
Power over Ethernet (PoE) operation—the 2600-PWR Series switches are
IEEE 802.3af compliant and provide up to 15.4W per port to power IP
phones, wireless access points, web cameras, and more. For more infor­
mation, see the POE Planning and Implementation Guide, which is on
the Documentation CD-ROM that is included with your switch.
■
The 2600-8-PWR switch supports some pre-standard PoE devices, for a
current list see the FAQ page for the 2600-8-PWR Switch, which can be
found on the ProCurve Web site, http://www.procurve.com, Technical
Support, FAQs (all).
■
plug-and-play networking—all ports are enabled—just connect the
network cables to active network devices and your switched network is
operational.
■
HP Auto-MDIX on all 10/100 twisted-pair ports, and IEEE 802.3ab Auto
MDI/MDI-X on all 10/100/1000 twisted-pair ports, meaning that all
twisted-pair connections can be made using straight-through
cables. Cross-over cables are not required, although they will also work.
■
automatic learning of the network addresses in each switch’s 8000­
address forwarding table, (with configurable address aging value).
1-11
Introducing the Switch
This port is used to connect a console to a Series 2600 Switch by using the
serial cable supplied with each switch. This connection is described under
“8. (Optional) Connect a Console to the Switch” on page 30 in chapter 2,
“Installing the Series 2600 Switches.” The console can be a PC or workstation
running a VT-100 terminal emulator, or a VT-100 terminal.
Introducing the Switch
Introducing the Switch
Switch Features
1-12
■
automatically negotiated full-duplex operation for the 10/100 and
10/100/1000 RJ-45 ports when connected to other auto-negotiating
devices—the mini-GBIC ports always operate at full duplex.
■
easy management of the switches through several available interfaces:
• console interface—a full featured, easy to use, VT-100 terminal
interface that is especially good for out-of-band switch management
or for Telnet access to the switch.
• web browser interface—an easy to use built-in graphical interface
that can be accessed from common web browsers.
• ProCurve Manager—an SNMP-based, graphical network manage­
ment tool that you can use to manage your entire network.
■
support for the Spanning Tree Protocol to eliminate network loops
■
support for up to 30 IEEE 802.1Q-compliant VLANs so you can divide the
attached end nodes into logical groupings that fit your business needs.
■
support for many advanced features to enhance network performance—
for a description, see the Management and Configuration Guide, which
is on the Documentation CD-ROM included with your switch.
■
download of new switch software for product enhancements or bug fixes.
2
Installing the Switch
The ProCurve Series 2600 Switches come with an accessory kit that includes
the brackets for mounting the switch in a standard 19-inch telco rack, in an
equipment cabinet, or on a wall. The brackets are designed to allow mounting
the switch in a variety of locations and orientations. Rubber feet are provided
that can be attached so the switch can be securely located on a horizontal
surface.
Included Parts
The Series 2600 Switches have the following components:
■
ProCurve Series 2600 Switches Installation and Getting Started Guide
(5991-2165), this manual
■
ProCurve Product Documentation CD ROM
(contains PDF file copies of the documentation for the Series 2600
Switches, including the Management and Configuration Guide, and
documentation for most other ProCurve switches)
■
ProCurve Manager - CD ROM and booklet
■
■
Console cable
Customer Support/Warranty booklet
■
Accessory kits
Switches 2626 and 2650 Non-PWR
and Switch 2600-8-PWR
Switches 2626-PWR and 2650-PWR
Kit number 5069-6535
Contains: • two mounting brackets
• eight 8-mm M4 screws to attach the
mounting brackets to the switch
• four 5/8-inch number 12-24 screws to
attach the switch to a rack
• four rubber feet
Kit number 5069-5705
Contains:
• two mounting brackets 1
• eight 8-mm M4 screws to attach the
mounting brackets to the switch
• four 5/8-inch number 12-24 screws to
attach the switch to a rack
• four rubber feet
1
The mounting brackets in this kit are longer to support the increased depth of the 2626­
PWR and 2650-PWR products.
2-1
Installing the Switch
This chapter shows you how to install your Series 2600 Switches.
Installing the Switch
Included Parts
Installing the Switch
■
AC power cord, one of the following:
Australia/New Zealand
China
Continental Europe
Denmark
Japan
Switzerland
United Kingdom/Hong Kong/Singapore
United States/Canada/Mexico
South Africa
Thailand
Taiwan
Non-PWR Switches
and 2600-8-PWR
PWR Switches 1
8120-6803
8120-8377
8120-6802
8120-6806
8120-6804
8120-6807
8120-8709
8120-6805
8120-8929
8121-0673
8121-0964
8120-6810
8120-8471
8120-6811
8120-6814
8120-6804
8120-6815
8120-6809
8120-2371
8120-8929
8121-0673
8121-0964
1 The cords for the PWR Switches support a higher amperage, except for the 2600-8-PWR.
Japan Power
Cord Warning
Please use the power cord supplied with your product. This power cord
is not to be used with other products.
2-2
Installing the Switch
Installation Procedures
Installation Procedures
These steps summarize your switch installation. The rest of this chapter
provides details on these steps.
1. Prepare the installation site (page 2-5). Make sure the physical envi­
ronment into which you will be installing the switch is properly prepared,
including having the correct network cabling ready to connect to the
switch and having an appropriate location for the switch. See page 2-4 for
some installation precautions.
3. Verify the switch passes self test (page 2-9). Plug the switch into a
power source and observe that the LEDs on the switch’s front panel
indicate correct switch operation.
4. Mount the switch (page 2-11). The Series 2600 Switches can be mounted
in a 19-inch telco rack, in an equipment cabinet, on a wall, or on a
horizontal surface. The Series 2600-PWR Switches may be mounted in
racks and cabinets or on a horizontal surface. The Switch 2626-PWR and
the 2650-PWR must not be wall mounted. The Switch 2600-8-PWR can be
wall mounted. See page 2-18 for wall mounting instructions.
5. Connect power to the switch (page 2-19). Once the switch is mounted,
plug it into the main power source.
6. Connect the network devices (page 2-20). Using the appropriate
network cables, connect the network devices to the switch ports.
7. Connect a 600 RPS/EPS or 610 EPS, (optional—page 2-21). You may
wish to use a 600 RPS/EPS or 610 EPS with your Series 2600-PWR Switch.
To do so you must connect these external power supplies using the RPS
or EPS cables supplied with these devices.
8. Connect a console to the switch (optional—page 2-30). You may wish
to modify the switch’s configuration, for example, to configure an IP
address so it can be managed using a web browser, from an SNMP network
management station, or through a Telnet session. Configuration changes
can be made by using the included console cable to connect a PC to the
switch’s console port.
At this point, your switch is fully installed. See the rest of this chapter if you
need more detailed information on any of these installation steps.
2-3
Installing the Switch
2. Install mini-GBICs (optional—page 2-7). The switch has two slots for
installing mini-GBICs. Depending on where you install the switch, it may
be easier to install the mini-GBICs first. Mini-GBICs can be hot swapped—
they can be installed or removed while the switch is powered on.
Installing the Switch
Installation Procedures
Installation Precautions
Follow these precautions when installing your ProCurve Series 2600 Switches.
WARNING
■
The rack or cabinet should be adequately secured to prevent it
from becoming unstable and/or falling over.
Installing the Switch
Devices installed in a rack or cabinet should be mounted as low as
possible, with the heaviest devices at the bottom and progressively
lighter devices installed above.
Cautions
2-4
■
For safe operation do not install the switch with the back of the
switch (with the fan vents) facing either downward or upward.
■
Do not wall mount the 2626-PWR or the 2650-PWR switches.
■
Ensure the power source circuits are properly grounded, then use the
power cord supplied with the switch to connect it to the power source.
■
If your installation requires a different power cord than the one supplied
with the switch, ensure the cord is adequately sized for the switch’s
current requirements. In addition, be sure to use a power cord displaying
the mark of the safety agency that defines the regulations for power cords
in your country. The mark is your assurance that the power cord can be
used safely with the switch. If the PWR device’s supplied power cord does
not fit, contact HP.
■
When installing the switch, the AC outlet should be near the switch and
should be easily accessible in case the switch must be powered off.
■
Ensure the switch does not overload the power circuits, wiring, and overcurrent protection. To determine the possibility of overloading the supply
circuits, add together the ampere ratings of all devices installed on the
same circuit as the switch and compare the total with the rating limit for
the circuit. Maximum ampere ratings are usually printed on the devices
near the AC power connectors.
■
Do not install the switch in an environment where the operating ambient
temperature might exceed 55 °C (131 °F), if using a 2600 switch, or 50 °C
(122 °F) if using a 2600-PWR switch.
■
Ensure the air flow around the sides and back of the switch is not
restricted. Leave at least 7.6 cm (3 inches) for cooling. If this unit is placed
in a fully-enclosed rack make certain the ambient temperature inside the
rack near the switch does not exceed 55 °C (if using a 2600 switch) or
50 °C (if using a 2600-PWR switch).
Installing the Switch
Installation Procedures
1. Prepare the Installation Site
■
Cabling Infrastructure - Ensure the cabling infrastructure meets the
necessary network specifications. See the following table for cable types
and lengths, and see appendix B, “Switch Ports and Network Cables” for
more information:
Table 2-1.
Port Type
Summary of Cable Types to Use With the Switch
Cable Type
Length Limits
Twisted-Pair Cables
10/100/1000Base-T
100 meters
Note: The Series 2600 Switches are
compatible with the IEEE 802.3ab standard
including the “Auto MDI/MDI-X” feature,
which allows use of either straight-through or
crossover twisted-pair cables for connecting
to any network devices including end nodes,
such as computers, or to other switches, hubs,
and routers.
Note: For 1000 Mbps operation, all four wire
pairs are used for data transmission, therefore
PoE is not supported for 1000 Mbps operation.
2-5
Installing the Switch
For either 10, 100 Mbps, or 1000 Mbps
operation:
Category 5 or better, 100-ohm UTP or shielded
twisted-pair (STP) balanced cable. For
1000 Mbps (gigabit) operation, Category 5e
cabling or better is recommended.
Installing the Switch
Installation Procedures
Port Type
Cable Type
Length Limits
Installing the Switch
Fiber Optic Cables
Gigabit-SX
(on Gigabit-SX-LC
mini-GBIC)
Multimode fiber-optic cables fitted with LC
connectors
220 meters to 550 meters depending on the
cable used. See “Fiber-Optic Cables” on page
B-2 for more information.
Gigabit-LX
(on Gigabit-LX-LC
mini-GBIC)
Single-mode fiber-optic cables fitted with LC
connectors.
• single-mode cable = 10 kilometers
• multimode cable = 550 meters
The multimode cables specified for the GigabitSX mini-GBIC may also be used, but a modeconditioning patch cord may be needed — see
“Mode Conditioning Patch Cord for Gigabit-LX”
on page B-3 for more information.
Gigabit-LH
(on Gigabit-LH-LC
mini-GBIC)
The same single-mode fiber-optic cables as for
Gigabit-LX.
• 70 kilometers
Note:
Gigabit-LH - Between the transmit and receive ends of the cable, at least 5db of attenuation is required for a reliable
connection. This is equivalent to 20Km of the fiber-optic cable. For distances less than 20Km, you must add attenuators
to bring the total attenuation to at least 5db. Most cable vendors carry attenuators.
■
2-6
Installation Location - Before installing the switch, plan its location and
orientation relative to other devices and equipment:
•
In the front of the switch, leave at least 7.6 cm (3 inches) of space for
the twisted-pair and fiber-optic cabling.
•
In the back of the switch, leave at least 3.8 cm (1 1/2 inches) of space
for the power cord.
•
On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling.
Installing the Switch
Installation Procedures
2. Installing or Removing mini-GBICs
You can install or remove a mini-GBIC from a mini-GBIC slot without having
to power off the switch. Use only ProCurve mini-GBICs.
Notes
■
The mini-GBIC slots are shared with the two 10/100/1000Base-T RJ-45
ports. If a mini-GBIC is installed in a slot, the associated RJ-45 port is
disabled and cannot be used.
■
The mini-GBIC ports operate only at full duplex. Half duplex operation is
not supported.
■
Ensure the network cable is NOT connected when you install or remove
a mini-GBIC.
Installing the Switch
When this manual was printed, the supported mini-GBICs include the
following:
Caution
■
ProCurve Gigabit-SX-LC mini-GBIC (J4858A and J4858B)
■
ProCurve Gigabit-LX-LC mini-GBIC (J4859A and J4859B)
■
ProCurve Gigabit-LH-LC mini-GBIC (J4860A and J4860B)
Use only supported genuine ProCurve mini-GBICs with your switch. NonProCurve mini-GBICs are not supported, and their use may result in product
malfunction. Should you require additional ProCurve mini-GBICs, contact
your ProCurve Networking Sales and Service Office or authorized dealer.
Installing the mini-GBICs:
Remove the protective plastic cover and retain it for later use. Hold the miniGBIC by its sides and gently insert it into either of the slots on the switch until
the mini-GBIC clicks into place.
WARNING
The ProCurve mini-GBICs are Class 1 laser devices. Avoid direct eye
exposure to the beam coming from the transmit port.
-T
Gig
rts
Po
48
46
44
42
40
38
39
47
T
47
45
T
49
M
43
41
48
se
! U
on
ly
on
50
M
e (T
or
M)
ea
for
ch
ab
Gig
iMinC
GBI
rts
Po
it po
rt
37
2-7
Installing the Switch
Installation Procedures
Removing the mini-GBICs
Note
You should disconnect the network cable from the mini-GBIC before removing
it from the switch.
Depending on when you purchased your ProCurve mini-GBIC, it may have
either of three different release mechanisms: a plastic tab on the bottom of
the mini-GBIC, a plastic collar around the mini-GBIC, or a wire bail.
Installing the Switch
To remove the mini-GBICs that have the plastic tab or plastic collar, push the
tab or collar toward the switch until you see the mini-GBIC release from the
switch (you can see it move outward slightly), and then pull it from the slot.
To remove the mini-GBICs that have the wire bail, lower the bail until it is
approximately horizontal, and then using the bail, pull the mini-GBIC from the
slot.
Replace the protective plastic cover on the mini-GBIC.
2-8
Installing the Switch
Installation Procedures
3. Verify the Switch Passes Self Test
Before mounting the switch in its network location, you should first verify it
is working properly by plugging it into a power source and verifying it passes
its self test.
1. Connect the power cord supplied with the switch to the power connector
on the back of the switch, and then into a properly grounded electrical
outlet.
2626 and 2650 non-PWR switches
Console
2626 PWR and 2650 PWR switches
HP ProCurve
RPS Input
12V 7.5A
Console
Line 50/60 Hz.
100-240 V~ 7.5 A
EPS Input
Connect power cord to
the power connector
Note
The Series 2600 Switches do not have a power switch. They are powered on
when the power cord is connected to the switch and to a power source. For
safety, the power outlet should be located near the switch installation.
The switch automatically adjusts to any voltage between 100-240 volts and
either 50 or 60 Hz. There are no voltage range settings required.
If your installation requires a different power cord than the one supplied with
the switch, be sure the cord is adequately sized for the switch’s current
requirements. In addition, be sure to use a power cord displaying the mark of
the safety agency that defines the regulations for power cords in your country.
The mark is your assurance that the power cord can be used safely with the
switch. If the PWR device’s supplied power cord does not fit, contact HP.
2-9
Installing the Switch
Connect power cord to
the power connector
Installing the Switch
Installation Procedures
2. Check the LEDs on the switch as described below.
Switch 2650
Switch port LEDs
Self Test LED
Installing the Switch
Power and
Fault LEDs
When the switch is powered on, it performs its diagnostic self test. Self test
takes approximately 50 seconds to complete.
Switch 2650-PWR
hp procurve
switch 2650-PWR
J8165A
1
1
3
5
7
9
11
2
4
6
8
10
12
Spd mode:
off = 10 Mbps,
11
13
12
14
13
15
17
19
21
23
14
16
18
20
22
24
Link|M
23
PoE
Status
RPS
Power
Fault
EPS
Fan
LED
Mode
Act
FDx
Spd
Test
PoE
Reset
Clear
2
flash = 100 Mbps,
on = 1000 Mbps
PoE-Ready 10/100Base-TX Ports (1 - 48)
24
Test LED
LED Behavior
During the self test:
2-10
•
Initially, all the switch and port LEDs are on. Most of the LEDs go off
and then may come on again during phases of the self test.
•
For the duration of the self test, the Self Test LED stays on.
Installing the Switch
Installation Procedures
When the self test completes successfully:
T
he Power and Fan Status LEDs remain on.
•
T
he Fault and Self Test LEDs go off.
•
The port LEDs on the front of the switch go into their normal opera­
tional mode:
– If the ports are connected to active network devices, the LEDs
behave according to the Port LED View or LED Mode selected.
For the non-PWR switches, in the default view mode (Link), the
LEDs should be on. For the PWR switches, with two LEDs per
connections, the Link LEDs will be on and the Mode LEDs will
flicker if there is network activity.
– If the ports are not connected to active network devices, the Link
and Activity LEDs will stay off.
If the LED display is different than what is described above, especially if
the Fault and Self Test LEDs stay on for more than 60 seconds or they start
blinking, the self test has not completed correctly. Refer to chapter 4,
“Troubleshooting” for diagnostic help.
4. Mount the Switch
After the switch passes self test, it is ready to be mounted in a stable location.
The Series 2600 Switches can be mounted in these ways:
1
Mounting Location
Non-PWR Switches
PWR Switches
In a rack or cabinet
Yes
Yes
On a horizontal surface
Yes
Yes
On a wall
Yes
No1
The 2600-8-PWR switch can be wall mounted. See page 2-18 for instructions.
Rack or Cabinet Mounting
The Series 2600 Switches are designed to be mounted in any EIA-standard 19­
inch telco rack or communication equipment cabinet. Note that the mounting
brackets have multiple mounting holes and can be rotated allowing for a wide
variety of mounting options. Secure the rack in accordance with the
manufacture’s safety guidelines.
WARNING
For safe operation, please read the mounting precautions on
page 2-4, before mounting a switch.
2-11
Installing the Switch
•
Installing the Switch
Installation Procedures
Equipment
Cabinet
Note
The 12-24 screws supplied with the switch are the correct threading for
standard EIA/TIA open 19-inch racks. If installing the switch in an equipment
cabinet such as a server cabinet, use the clips and screws that came with the
cabinet in place of the 12-24 screws that are supplied with the switch.
Rack Mounting the 2626-PWR and 2650-PWR switches
Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 8-mm M4 screws.
Installing the Switch
1.
WARNING
2-12
For safe reliable installation, only use the screws provided in the
accessory kit to attach the mounting brackets to the switch.
Installing the Switch
Installation Procedures
Note
The mounting brackets have multiple mounting holes and can be rotated
allowing for a wide variety of mounting options. These include mounting the
switch so that its front face is flush with the face of the rack, or mounting it
in a more balanced position as shown in the illustration above.
2.
Hold the switch with attached brackets up to the rack and move it
vertically until rack holes line up with the bracket holes, then insert and
tighten the four number 12-24 screws holding the brackets to the rack.
Installing the Switch
2-13
Installing the Switch
Installation Procedures
Rack Mounting the Non-PWR Switches
and the 2600-8-PWR Switch
Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 8-mm M4 screws.
Installing the Switch
1.
8 mm
M4 screws
Note
The mounting brackets have multiple mounting holes and can be rotated
allowing for a wide variety of mounting options. These include mounting the
switch so that its front face is flush with the face of the rack, or mounting it
in a more balanced position as shown in the illustration.
WARNING
For safe reliable installation, only use the screws provided in the
accessory kit to attach the mounting brackets to the switch.
2-14
Installing the Switch
Installation Procedures
2. Hold the switch with attached brackets up to the rack and move it
vertically until rack holes line up with the bracket holes, then insert and
tighten the four number 12-24 screws holding the brackets to the rack.
Install 12-24
screws
Installing the Switch
2-15
Installing the Switch
Installation Procedures
Flat Wall Mounting
You can mount the Non-PWR switches on a wall as shown in the illustration
on the next page. However, this is not supported for the 2626-PWR or the 2650­
PWR switches. Wall mounting the PWR switches is not supported because of
the size and weight of the devices. Wall mounting the 2600-8-PWR switch is
supported. See page 2-18 for instructions.
For safe operation do not install the switch with the back face of the
switch (with the fan vents) facing either downward or upward. Do not
wall mount the 2626-PWR or the 2650-PWR switches.
Caution
The switch should be mounted only to a wall or wood surface that is at least
1/2-inch (12.7 mm) plywood or its equivalent.
Installing the Switch
WARNING
Supported Wall Mounting Positions.
Switch
2-16
Vertical Wall Mounting
Horizontal Wall Mounting
2626 Non-PWR
Yes
No
2650 Non-PWR
Yes
No
2626-PWR
No
No
2650-PWR
No
No
2600-8-PWR
No
Yes
Installing the Switch
Installation Procedures
Wall mounting the Series 2600 Non-PWR Switches
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to opposite corners of the switch with the included 8-mm M4
screws.
2. Attach the switch to the wall or wood surface with two 5/8-inch (15.875
mm) number 12 wood screws (not included).
For “Flat” Wall Mounting (Vertical)
Installing the Switch
M4 screws
Wall
5/8-inch
wood screws
The brackets are attached on
opposite corners to improve the
stability of the switch on the wall.
WARNING
The Switch 2626-PWR or 2650-PWR Switches are not wall mountable.
2-17
Installing the Switch
Installation Procedures
Wall mounting the Series 2600-8-PWR Switch
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 8-mm M4 screws.
2. Attach the switch to the wall or wood surface with two 5/8-inch number
12 wood screws (not included).
For “Flat” Wall Mounting (Horizontal)
Installing the Switch
RJ-45 Ports
Wall
5/8-inch
wood screws
M4 screws
Caution
2-18
The 2600-8-PWR switch can only be wall mounted either with the RJ-45 ports
side up or down (horizontally). A vertical wall mount orientation is not
supported.
Installing the Switch
Installation Procedures
Horizontal Surface Mounting
Place the switch on a table or other horizontal surface. The switch comes with
rubber feet in the accessory kit that can be used to help keep the switch from
sliding on the surface.
Attach the rubber feet to the four corners on the bottom of the switch within
the embossed angled lines. Use a sturdy surface in an uncluttered area. You
may want to secure the networking cables and switch power cord to the table
leg or other part of the surface structure to help prevent tripping over the
cords.
Caution
Ensure the air flow is not restricted around the sides and back of the switch.
1. Plug the included power cord into the switch’s power connector and into
a nearby AC power source.
2. Re-check the LEDs during self test. See “LED Behavior” on page 2-10.
2-19
Installing the Switch
5. Connect the Switch to a Power Source
Installing the Switch
Installation Procedures
6. Connect the Network Cables
Connect the network cables, described under “Cabling Infrastructure” (page
2-5), from the network devices or your patch panels to the fixed RJ-45 ports
on the switch or to any mini-GBICs you have installed in the switch.
Using the RJ-45 Connectors
Installing the Switch
To connect:
Push the RJ-45 plug into the RJ-45
port until the tab on the plug clicks
into place. When power is on for the
switch and for the connected device,
the Link LED for the port should light
to confirm a powered-on device (for
example, an end node) is at the other
end of the cable.
If the Link LED does not go on when
the network cable is connected to the
port, see “Diagnosing With the LEDs”
in chapter 4, “Troubleshooting”.
To disconnect:
Press the small tab on the plug and
pull the plug out of the port.
2-20
hp procurve
switch 2650
1
1
2
3
4
5
6
J4899A
Self
Test
Fan
Status
eset
Port
LED
View
Lnk
Act
FDx
Spd
Clear
Spd mode:
off = 10 Mbps,
flash =
RJ-45 connector
Unshielded twisted-pair cable:
• Category 3, 4, or 5 for 10 Mbps ports
• Category 5 or better for 100 Mbps ports
• Category 5e or better for 1000 Mbps ports
Maximum distance: 100 meters
Installing the Switch
Installation Procedures
Connecting Cables to mini-GBICs
Note
The mini-GBIC slots are shared with the two 10/100/1000Base-T RJ-45 ports.
If a mini-GBIC is installed in a slot, the associated RJ-45 port is disabled.
If you have any mini-GBICs installed in the switch, the type of network
connections you will need to use depends on the type of mini-GBICs you have
installed. See the table on page 2-5, and appendix B, “Switch Ports and
Network Cables”, for the mini-GBIC cabling information.
7. (Optional) Connect a Redundant Power Supply
to a Series 2600-PWR Switch
The ProCurve 600 Redundant and External Power Supply, (J8168A), hereafter
referred to as the 600 RPS/EPS, is an accessory product for the Series 2600­
PWR Switches and specific other ProCurve switches. The 600 RPS/EPS
provides two types of power to the switches:
■
Redundant power to one of up to six switches, to back up the internal
switch power supply in case of AC power loss, or a fault condition. Should
the internal switch power supply fail, power will be supplied from the 600
RPS/EPS, if it is available, that is, if the 600 RPS/EPS is not already
providing power to a higher priority switch. See the documentation that
came with your 600 RPS/EPS for more information.
■
External Power-over-Ethernet (PoE) power to up to two switch products.
The 600 RPS/EPS can supply 408 watts of PoE power to the switch if the
internal PoE power supply should fail. For the Switch 2650-PWR the
external PoE power is additional power made available to the switch’s
ports. For further information regarding the 600 RPS/EPS PoE
capabilities, see the PoE Planning and Implementation Guide and the
ProCurve 600/610 External Power Supplies Installation and Getting
Started Guide, which is on the Documentation CD-ROM that came with
your switch.
The 600 RPS/EPS is an unmanaged power supply that only provides
information by way of LEDs.
2-21
Installing the Switch
For mini-GBICs ports, and in general for all the switch ports, when a network
cable from an active network device is connected to the port, the port LED
for that port should go on. If the port LED does not go on when the network
cable is connected to the port, see “Diagnosing with the LEDs” in chapter 4,
“Troubleshooting”.
Installing the Switch
Installation Procedures
RPS/EPS Operation
The RPS/EPS monitors the power signal from the switch by detecting that the
RPS/EPS is connected to a switch with an RPS/EPS cable. When the power
from the switch is no longer detected, the RPS/EPS will turn on and provide
power to the switch within 1 millisecond.
The RPS/EPS supports hot plugging of the RPS/EPS cable without causing a
reboot of the switch or causing the power supply in either the RPS/EPS or
switch to shut down temporarily or permanently. For more information refer
to the documentation that came with the RPS/EPS.
Installing the Switch
Operating Characteristics of the 600 RPS/EPS (J8168A)
The 600 RPS/EPS has six RPS ports, each of which can provide redundant
+12V power to a connected switch, but only one connector can provide this
power at a given time.
If a switch with no AC power is connected to an operating 600 RPS/EPS, it
will receive power if power is available (no higher priority port is already using
the RPS power).
If two or more devices fail, priority goes to the device plugged into the lower
numbered port on the 600 RPS/EPS unit. Consequently the most important
switch should be plugged into port one on the 600 RPSEPS. In this state, the
“Connected” LED should be ON, and the “Power Status” LED should be
BLINKING on the lower priority RPS port not supplying power. (Refer to the
documentation that came with your 600 RPS/EPS unit.)
The 600 RPS/EPS also has two EPS Ports. The 600 RPS/EPS can provide a
maximum of 408 watts of PoE power to a switch. It is important to understand
the PoE power requirements of the 2600-PWR Series switches because if the
PoE power is not planned and implemented correctly the end devices
connected to the switch ports may not receive power if an internal switch PoE
power supply should fail. For further information regarding the 600 RPS/EPS
PoE capabilities, see the PoE Planning and Implementation Guide and the
ProCurve 600/610 External Power Supplies Installation and Getting Started
Guide, which is on the Documentation CD-ROM that came with your switch.
For redundant AC power, connect the 600 RPS/EPS to the switch using one
of the six supplied RPS cables. RPS cables are 1.25 meters (4.10 feet) in length.
For redundant or additional PoE power, connect the 600 RPS/EPS to the
switch using one of the two supplied EPS cables. EPS cables are 2.00 meters
(6.56 feet) in length.
2-22
Installing the Switch
Installation Procedures
600 RPS/EPS LEDs
The 600 RPS/EPS LEDs are located on the back of the device. These LEDs are
duplicated on the front of the device for your convenience. The following
graphic shows an example of the back of the 600 EPS/RPS. There are two
green LEDs for each RPS and EPS port:
■
Device Connected
■
Power Status
RPS Power Status LED
RPS Device Connected LED
RPS 3
backup to one connected device. Lowest-numbered port has priority.
R3
!
R4
RPS 4
R5
RPS 5
R6
RPS 6
EPS Power: 50V
EPS 1
EPS Power Status LED
370W total for PoE applications. Power is shared when
E1
EPS 2
Installing the Switch
RPS Power: 12V
EPS Device Connected LED
both ports are used.
Device
E2 Connected
Power
Status
Line: 50/60 Hz.
10 0 - 240 V~ 9.1A (9,1A)
The following states provide status of the RPS and EPS ports.
Fault (located on Device
the front)
Connected
Power
Status
Message
Off
Off
Off
Nothing Connected
On or Off
Off
On
Not a valid state - should never happen
Off
On
Off
Switch is connected, RPS is available but
not required
Off
On
On
RPS is powering the connected device
Blinking
Off
Blinking
RPS/EPS port is in fault condition
Off
On
Blinking
Switch is requesting power, RPS can not
provide it. (N/A for EPS)
2-23
Installing the Switch
Installation Procedures
600 RPS/EPS Connectivity
The following illustration shows an example of connectivity between an RPS/
EPS device and a switch device as a redundant AC power supply.
RPS Power: 12V
RPS 1
Device Connected R1
Power Status
RPS 2
R2
RPS 3
backup to one connected device. Lowest-numbered port has priority.
R3
RPS 4
!
R4
RPS 5
R5
RPS 6
R6
EPS Power: 50V
EPS 1
370W total for PoE applications. Power is shared when
E1
both ports are used.
Device
EPS 2
E2 Connected
Power
Status
Line: 50/60 Hz.
10 0 - 240 V~ 9.1A (9,1A)
Switch RPS output port
Installing the Switch
HP ProCurve
RPS Input
7.5A
12V
Console
EPS Input
RPS input port
2-24
Line 50/60 Hz.
100-240 V~ 7.5 A
Installing the Switch
Installation Procedures
The following illustration shows an example of connectivity between an RPS/
EPS device and six switch devices as a redundant AC power supply.
2650-PWR switches
Installing the Switch
Highest priority
connected to port 1
600 RPS/EPS
The 600 RPS/EPS can provide backup power for up to six switches. The 600
RPS/EPS can supply power to only one connected and failed switch at a time.
In the illustration above, the switch connected to RPS port 1 has the highest
priority and the switch connected to RPS port 6 has the lowest priority. When
multiple switches fail, a switch connected to a higher priority port always
receives power before a switch connected to a lower priority port.
2-25
Installing the Switch
Installation Procedures
The following illustration demonstrates an example of connectivity between
an RPS/EPS device and a Switch device as a PoE power supply.
RPS Power: 12V
RPS 1
Device Connected R1
Power Status
RPS 2
R2
RPS 3
EPS Power: 50V
backup to one connected device. Lowest-numbered port has priority.
R3
RPS 4
R4
RPS 5
R5
RPS 6
R6
EPS 1
370W total for PoE applications. Power is shared when
E1
both ports are used.
Device
EPS 2
E2 Connected
Power
Status
Line: 50/60 Hz.
100 -240 V~ 9.1A (9,1A)
Switch EPS output
Installing the Switch
HP ProCurve
RPS Input
12V 7.5A
Console
EPS Input
EPS input port
2-26
Line 50/60 Hz.
100-240 V~ 7.5 A
Installing the Switch
Installation Procedures
610 EPS LEDs
Power and
Fault LEDs
Backup Power
Port LEDs
hp procurve
EPS Ports
Pair A (408 W total for PoE applications)
610 eps
EPS A1
J8169A
Power
A1 Device
Connected
Power
Status
EPS A2
EPS Ports
A2
Pair B (408 W total for PoE applications)
EPS B1
B1 Device
Connected
Power
Status
EPS B2
B2
Backup Power Ports Status
Internal Power Status
Fan/Temp Status
Fault
610 EPS
EPS Port LEDs
In Ready
Out Ready
EPS Ports: 50V
8.3A max each.
Fan/Temp Status flash = Temperature too high
Fan/Temp Status + Fault flash = Fan failure
Fan/Temp
Status LED
Internal Power
Status LED
Power Status
LED
Device Connected
LED
Operating Characteristics of the 610 EPS (J8169A)
The 610 EPS does not have any RPS ports and can not supply RPS power. It
has four EPS Ports. Two in Pair A and two in Pair B. Each pair can provide a
maximum of 408 watts of PoE power to a switch. Again, it is important to
understand the PoE power requirements of the switches. For further
information regarding the 610 EPS PoE capabilities, see the PoE Planning
and Implementation Guide, which is on the Documentation CD-ROM that
came with your switch and the documentation that came with the 610 EPS.
For redundant or additional PoE power, connect the 610 EPS to the switch
using one of the four supplied EPS cables. EPS cables are 2.00 meters (6.56
feet) in length.
The following illustration demonstrates and example of connectivity between
a 610 EPS device and two Switch devices as a PoE power supply.
2-27
Installing the Switch
For a complete description of the LEDs see the documentation that came with
the 610 EPS.
Installing the Switch
Installation Procedures
50 V
16 A
50 V
16 A
12 V
RPS
7.5 A
12 V
RPS
7.5 A
Installing the Switch
hp procurve
610 eps
Line: 50/60 Hz.
100-240 V~ 7.5 A
Line: 50/60 Hz.
100-240 V~ 7.5 A
EPS Ports
Pair A (408 W total for PoE applications)
EPS A1
J8169A
A1 Device
Connected
Power
Status
EPS Ports
Pair B (408 W total for PoE applications)
A2
EPS A2
EPS B1
B1 Device
Connected
Power
Status
B2
EPS B2
Backup Power Ports Status
Pow er
Internal Power Status
Fan/Temp Status
Fault
In Ready
Out Ready
EPS Ports: 50V
8.3A max each.
Fan/Temp Status flash = Temperature too high
Fan/Temp Status + Fault flash = Fan failure
In this example each switch receives 408 watts of PoE power. Each switch is
connected to one port of each pair. If the two switches were connected to both
ports of a pair, both ports of pair A for example, then each switch receives 204
watts. See the following example.
The following illustration demonstrates an example of connectivity between
a 610 EPS device and four Switch devices as a PoE power supply. In this
example each switch receives 204 watts of PoE power.
2-28
Installing the Switch
Installation Procedures
16 A
50 V
16 A
50 V
16 A
50 V
16 A
12 V
RPS
7.5 A
12 V
RPS
7.5 A
12 V
RPS
7.5 A
12 V
RPS
7.5 A
hp procurve
Line: 50/60 Hz.
100-240 V~ 7.5 A
Line: 50/60 Hz.
100-240 V~ 7.5 A
Line: 50/60 Hz.
100-240 V~ 7.5 A
Line: 50/60 Hz.
100-240 V~ 7.5 A
EPS Ports
Pair A (408 W total for PoE applications)
610 eps
EPS A1
J8169A
A1 Device
Connected
Power
Status
EPS Ports
Pair B (408 W total for PoE applications)
A2
EPS A2
Installing the Switch
50 V
EPS B1
B1 Device
Connected
Power
Status
B2
EPS B2
Backup Power Ports Status
Pow er
Internal Power Status
Fan/Temp Status
Fault
In Ready
Out Ready
EPS Ports: 50V
8.3A max each.
Fan/Temp Status flash = Temperature too high
Fan/Temp Status + Fault flash = Fan failure
2-29
Installing the Switch
Installation Procedures
8. (Optional) Connect a Console to the Switch
The Series 2600 Switches have a full-featured, easy to use console interface
for performing switch management tasks including the following:
■
monitor switch and port status and observe network activity statistics
■
modify the switch’s configuration to optimize switch performance,
enhance network traffic control, and improve network security
■
read the event log and access diagnostic tools to help in troubleshooting
■
download new software to the switch
■
add passwords to control access to the switch from the console, web
browser interface, and network management stations
Installing the Switch
The console can be accessed through these methods:
■
Out-of-band: The Series 2600 Switches come with a serial cable for
connecting a PC or VT-100 terminal, to be used as a console, directly to
the switch.
■
In-Band: Access the console using Telnet from a PC or UNIX station on
the network, and a VT-100 terminal emulator. This method requires that
you first configure the switch with an IP address and subnet mask by using
either out-of-band console access or through DHCP/Bootp. For more
information on IP addressing and on starting a Telnet session, see
chapter 3, “Configuring the Switch”, in the Management and
Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
The Series 2600 Switches can simultaneously support one out-of-band console
session through the Console Port and in-band Telnet console sessions.
Terminal Configuration
To connect a console to the switch, configure the PC terminal emulator as a
DEC VT-100 (ANSI) terminal or use a VT-100 terminal, and configure either
one to operate with these settings:
■
any baud rate from 1200 to 115200 (the switch senses the speed)
■
8 data bits, 1 stop bit, no parity, and flow control set to Xon/Xoff
■
for the Windows Terminal program, also disable (uncheck) the “Use
Function, Arrow, and Ctrl Keys for Windows” option
■
for the Hilgraeve HyperTerminal program, select the “Terminal keys”
option for the “Function, arrow, and ctrl keys act as” parameter
If you want to operate the console using a different configuration, make sure
you change the settings on both the terminal and on the switch so they are
compatible. Change the switch settings first, then change the terminal
settings, then reboot the switch and reestablish the console session.
2-30
Installing the Switch
Installation Procedures
Direct Console Access
To connect a console to the
switch, follow these steps:
Console
2. Turn on the terminal or
PC’s power and, if using a
PC, start the PC terminal
program.
Console port
Console cable supplied
with the switch
Installing the Switch
1. Connect the PC or
terminal to the switch’s
Console Port using the
console cable included
with the switch. (If your
PC or terminal has a 25-pin
serial connector, first
attach a 9-pin to 25-pin
straight-through adapter
at one end of the console
cable.)
PC running a terminal
emulator program, or
a VT-100 terminal
3. Press [Enter] two or three times and you will see the copyright page and
the message “Press any key to continue”. Press a key, and you will then
see the switch console command (CLI) prompt, for example:
ProCurve Switch #
If you want to continue with console management of the switch at this time,
see chapter 3, “Getting Started With Switch Configuration” for some basic
configuration steps. For more detailed information, refer to the Management
and Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
2-31
Installing the Switch
Sample Network Topologies for Non-PWR Switches
Sample Network Topologies for
Non-PWR Switches
This section shows a few sample network topologies in which the Switch 2650
is implemented. For more topology information, see the ProCurve networking
products Web site, http://www.procurve.com.
Installing the Switch
As a Desktop Switch
Server
Twisted-pair
straight-through
or crossover
cables
Switch 2650
PCs and
peripherals
The Series 2600 Switches are designed to be used primarily as desktop
switches to which end nodes, printers, other peripherals, and servers are
directly connected, as shown in the above illustration. The end node devices
are connected to the switch by straight-through or crossover twisted-pair
cables. Either cable type can be used because of the “HP Auto-MDIX” and
“IEEE Auto MDI/MDI-X” features on the Series 2600 Switches.
2-32
Installing the Switch
Sample Network Topologies for Non-PWR Switches
As a Segment Switch
Category 5e twisted-pair straight-through or
crossover cable for 1000 Mbps connection to server
Server with
Gigabit
Ethernet NIC
Gigabit
fiber-optic cable
to backbone
Switch 2650
Twisted-pair straight-through
or crossover cables to hubs
Installing the Switch
Switch 2650
Switch 2650
Twisted-pair
straight-through
cables to
end nodes
PCs,
printers,
and local
servers
The Series 2600 Switches also work well as segment switches. That is, with
their high performance, they can be used for interconnecting network
segments—simply connect the network devices that form those segments to
the Series 2600 Switches.
In the illustration above, two “Fast Ethernet” switches with PCs, printers, and
local servers attached, are both connected to a Switch 2650. The devices
attached to the two desktop switches can now communicate with each other
through the switch. They can also all communicate with the server that is
connected to a 1000Base-T port on the switch.
2-33
Installing the Switch
Sample Network Topologies for Non-PWR Switches
Because the Series 2600 Switches have the “HP Auto-MDIX” and “IEEE Auto
MDI/MDI-X” features, the connections between the switch and the hubs, and
between the switch and end nodes or servers can be through category 5
straight-through or crossover twisted-pair cable. Category 3 or 4 cable can
also be used if the connection is 10 Mbps only. In all cases, the device ports
must be configured to auto negotiate the link characteristics for this feature
to work.
Installing the Switch
The switch, in turn, can be connected to a network backbone through fiberoptic cabling connected to a Gigabit-SX, -LX, or -LH mini-GBIC. Now, all the
devices on these network segments can access other network resources that
are connected elsewhere on the network backbone. Always remember when
connecting fiber-optics that all components match in specification.
2-34
Installing the Switch
Sample Network Topologies for Non-PWR Switches
Connecting to a Backbone Switch
To Gigabit-Ethernet
backbone
Switch 5308xl
Installing the Switch
Switch 2650
Gigabit
fiber-optic cables
Switch 2650
Switch 2650
Switch 2650
The simpler desktop and segment networks shown in the previous two
examples can easily be combined and expanded. For example, you could use
an ProCurve Switch 5308xl to interconnect each of your smaller switched
workgroups to form a larger switched network. All the devices in this network
can communicate with each other. For example, with Gigabit-SX Mini-GBICs
installed in a Mini-GBIC Module, in the Switch 5308xl, the entire switched
topology could be connected to a campus backbone, as shown in the
illustration above.
Note
In the illustration above, the 1000 Mbps fiber-optic connection between the
Switch 2650s and the Switch 5308xl is by way of a Gigabit-SX mini-GBIC
installed in the Switch 2650s connected to a mini-GBIC Module in the 5308xl.
2-35
Installing the Switch
Sample Network Topologies for PWR Switches
Sample Network Topologies for PWR
Switches
This section shows a few sample network topologies implementing the Series
2600-PWR Switches. For more topology information, see the ProCurve
networking products Web site, http://www.procurve.com.
As a Desktop Switch Implementing PoE
Installing the Switch
600 RPS/EPS
Twisted-pair
straight-through
or crossover
cables
Wireless Access
Point
Server
2650-PWR
IP Telephones
PCs and
peripherals
The Series 2600-PWR Switches are also designed to be used as desktop
switches to which end nodes, printers and other peripherals, and servers are
directly connected, as shown in the above illustration. Except now these
switches can supply PoE power to end devices such as IP telephones and
wireless access points (WAP).
As shown in the above illustration the IP telephones can be connected in line,
that is, between the switch and the end device, in this case a PC. The IP
telephones have two ports, one in and one out. Therefore the phone receives
voice and power from the switch and the PC can send and receive data through
the phone to the switch.
The end node devices are connected to the switch by straight-through or
crossover twisted-pair cables. Either cable type can be used because of the
“HP Auto-MDIX” and “IEEE Auto MDI/MDI-X” features on the Series 2600PWR Switches.
2-36
Installing the Switch
Sample Network Topologies for PWR Switches
As a Segment Switch Implementing PoE
Category 5e twisted-pair straight-through or
crossover cable for 1000 Mbps connection to server
Server with
Gigabit
Ethernet NIC
600 RPS/EPS
Switch 2650 Non-PWR
Gigabit
fiber-optic cable
uplink
Switch 2600-8-PWR
* Spd mode:
ProCur ve
of
f = 10 Mbps,
flash = 0
10 Mbps,
on = 0
100 Mbps
Switc h 2600-PWR
J8762A
Link
RPS
Fault
EPS
Fan
Dual-Personality P ort:
10/1 00/1 000-T (T) o r Mini-GBIC (M)
PoE-Int egrated 10/1 00-TX P orts (1 - 8) — (Ports are HP A uto-MDIX)
(P ort 9T is IEEE A uto MDI/MDIX)
P oE
S tatus
Power
Switch
2650-PWR
Act
LED
Mode
FDx
Spd
1
Mode
2
3
4
Link
5
Mode
6
7
8
Link
9T
9M
Mode
Link
*
Test
PoE
Reset
Clear
Mode
Console
! Use only one (T or M) f or Port 9
Wireless
Access Points
PCs, printers,
and local
servers
As shown in the illustration above, the IP telephones have been inserted in
between the Switch 2650-PWR and the PCs, and a WAP has been connected
to the Switch 2650-PWR. Both the telephones and WAP will receive PoE power
from the Switch 2650-PWR. Only devices directly connected to the PWR
switches can receive PoE power if they are 802.3af compliant, except on the
Switch 2600-8-PWR, it has the ability to supply power to pre-802.3af-standard
devices, such as legacy (or non-standard) IP phones. Devices connected to a
non-PWR segment switch cannot receive PoE power.
2-37
Installing the Switch
Twisted-pair straightthrough or crossover cables
Installing the Switch
Sample Network Topologies for PWR Switches
Connecting to a Backbone Switch Implementing PoE
To Gigabit-Ethernet
backbone
Switch 5308xl
Installing the Switch
Switch 2650
Gigabit
fiber-optic
cable
Switch 2650 non-PWR
Switch 2650-PWR
Wireless
Access Point
2-38
600 RPS/EPS
Switch 2650-PWR
Installing the Switch
Sample Network Topologies for PWR Switches
Stacking the Switch
Switch 2600 and 2600-PWR Series devices can be connected together, through
standard network connections, and managed through a single IP address. Up
to 16 switches can be connected together in such a “virtual stack”.
You identify a Switch 2600 or 2600-PWR Series device as the “Commander”
and give that switch an IP address. Up to 15 other switches in the network can
then easily be configured as Members of the stack and managed through the
Commander’s IP address. The management includes Telnet access and web
browser interface access to the Commander and to each Member switch
through the Commander.
2-39
Installing the Switch
For more information on stacking your switch, see the Management and
Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
— This page is intentionally unused. —
3
Configuring the Switch
This chapter is a guide for using the console Switch Setup screen to quickly
assign an IP (Internet Protocol) address and subnet mask to the switch, set a
Manager password, and, optionally, configure other basic features.
For more information on using the switch console and the web browser
interface, please see the Management and Configuration Guide, which is on
the Documentation CD-ROM that came with your switch.
Recommended Minimal Configuration
Many other features can be configured through the switch’s console interface,
to optimize the switch’s performance, to enhance your control of the network
traffic, and to improve network security. Once an IP address has been
configured on the switch, these features can be accessed more conveniently
through a remote Telnet session, through the switch’s web browser interface,
and from an SNMP network management station running a network
management program. For a listing of switch features available with and
without an IP address, refer to “How IP Addressing Affects Switch Operation”
in the Management and Configuration Guide, which is on the
Documentation CD-ROM that came with your switch.
For more information on IP addressing, refer to “IP Configuration” in the
Management and Configuration Guide.
3-1
Configuring the Switch
In the factory default configuration, the switch has no IP (Internet Protocol)
address and subnet mask, and no passwords. In this state, it can be managed
only through a direct console connection. To manage the switch through inband (networked) access, you should configure the switch with an IP address
and subnet mask compatible with your network. Also, you should configure
a Manager password to control access privileges from the console and web
browser interface. Other parameters in the Switch Setup screen can be left at
their default settings or you can configure them with values you enter.
Configuring the Switch
Note
By default, the switch is configured to acquire an IP address configuration
from a DHCP or Bootp server. To use DHCP/Bootp instead of the manual
method described in this chapter, see “DHCP/Bootp Operation” in the
Management and Configuration Guide, which is on the Documentation
CD-ROM that came with your switch.
Using the Console Setup Screen
The quickest and easiest way to minimally configure the switch for
management and password protection in your network is to use a direct
console connection to the switch, start a console session, and access the
Switch Setup screen.
1. Using the method described in the preceding section, connect a terminal
device to the switch and display the switch console command line
interface (CLI) prompt (the default display).
The CLI prompt appears, for example:
ProCurve#
2. At the prompt, enter the setup command to display the Switch Setup
screen. The following illustration shows the Setup screen with the default
settings.
Configuring the Switch
2005
3.
3-2
Use the [Tab] key to select the Manager Password field and enter a manager
password of up to 16 printable ASCII characters.
Configuring the Switch
4. [Tab] to the IP Config (DHCP/Bootp) field and use the Space bar to select the
Manual option.
5. [Tab] to the IP Address field and enter the IP address that is compatible with
your network.
6. [Tab] to the Subnet Mask field and enter the subnet mask used for your
network.
7.
Press [Enter], then [S] (for Save).
Here is some information on the fields in the Setup screen. For more information on these fields, see the Management and Configuration Guide,
which is on the Documentation CD-ROM that came with your switch:
Default
System Name
blank
Optional; up to 25 characters, including spaces
System Contact
blank
Optional; up to 48 characters, including spaces
Manager Password
blank
Recommended; up to 16 characters (no blank spaces)
Logon Default
CLI
The default setting selects the command line interface for console access.
The alternative is the menu interface.
Time Zone
0 (none)
Optional; 1440 to -1440. The number of minutes your location is to the West (-)
or East (+) of GMT.
Community Name
public
Default setting recommended.
Spanning Tree Enabled
No
Default setting recommended unless STP is already running on your network
or the switch will be used in complex network topologies.
Default Gateway
blank
Optional; Enter the IP address of the next-hop gateway node if network traffic
needs to be able to reach off-subnet destinations.
Time Sync Method
None
Optional; The protocol the switch uses to acquire a time signal. The options
are SNTP and TimeP.
TimeP Mode
Disabled
Optional; The method the switch uses to acquire the TimeP server address.
IP Config (DHCP/Bootp)
DHCP/Bootp
Set to Manual unless a DHCP/Bootp server is used on your network to
configure IP addressing.
IP Address
xxx.xxx.xxx.xxx Recommended; If you set IP Config to Manual, then enter an IP address
compatible with your network.
Note: The IP address and subnet mask assigned for the switch must be compatible with the IP addressing used in
your network. For more information on IP addressing, see the Management and Configuration Guide, which is on the
Documentation CD-ROM that came with your switch.
Subnet Mask
xxx.xxx.xxx.xxx Recommended; If you entered an IP address, then enter a subnet mask
compatible with your network.
3-3
Configuring the Switch
Parameter
Configuring the Switch
Where to Go From Here
The above procedure configures your switch with a Manager password, IP
address, and subnet mask. As a result, with the proper network connections,
you can now manage the switch from a PC equipped with Telnet, and/or a web
browser interface.
Some basic information on managing your switch is included in the next
section. For more information on the console, web browser, and SNMP
management interfaces and all the features that can be configured on the
Series 2600 Switches, see the Management and Configuration Guide, which
is on the Documentation CD-ROM that came with your switch.
Configuring the Switch
To Recover from a Lost Manager Password: If you cannot start a
console session at the manager level because of a lost Manager password, you
can clear all passwords and user names by getting physical access to the
switch and pressing and holding the Clear button for a full second.
3-4
Configuring the Switch
Using the IP Address for Remote Switch Management
Using the IP Address for Remote Switch
Management
With your switch, you can use the switch’s IP address to manage the switch
from any PC that is on the same subnet as the switch. You can use either a
Telnet session or a standard web browser to manage the switch.
Starting a Telnet Session
To access the switch through a Telnet session, follow these steps:
1. Make sure the switch is configured with an IP address and that the switch
is reachable from the PC that is running the Telnet session (for example,
by using a Ping command to the switch’s IP address).
2. Start the Telnet program on a PC that is on the same subnet as the switch
and connect to the switch’s IP address.
3. You will see the copyright page and the message “Press any key to
continue”. Press a key, and you will then see the switch console command
(CLI) prompt, for example:
ProCurve#
Starting a Web Browser Session
The Series 2600 Switches can be managed through a graphical interface that
you can access from any PC or workstation on the network by running your
web browser and typing in the switch’s IP address as the URL. No additional
software installation is required to make this interface available; it is included
in the switch’s onboard software.
A typical web browser interface screen is shown in the next illustration.
3-5
Configuring the Switch
Enter help or ? to see a list of commands that can be executed at the
prompt. Entering any command followed by help provides more detailed
context help information about the command. Entering any command
followed by ? displays a list of options that are available at that point in
the command entry.
Configuring the Switch
Using the IP Address for Remote Switch Management
For more information on using the web browser interface, please see the
Management and Configuration Guide, which is on the Documentation
CD-ROM that came with your switch.
Configuring the Switch
An extensive help system is also available for the web browser interface. To
access the help system though, the subnet on which the switch is installed
must have access to the internet.
3-6
4
Troubleshooting
This chapter describes how to troubleshoot your ProCurve Series 2600
Switch. This document describes troubleshooting mostly from a hardware
perspective. You can perform more in-depth troubleshooting on these devices
using the software tools available with the switches, including the fullfeatured console interface, the built-in web browser interface, and ProCurve
Manager, the SNMP-based network management tool. For more information,
see the chapter “Troubleshooting” in the Management and Configuration
Guide, which is on the Documentation CD-ROM that came with your switch.
This chapter describes the following:
■
basic troubleshooting tips (page 4-1)
■
diagnosing with the LEDs (page 4-4)
■
proactive networking tools (page 4-8)
■
hardware diagnostic tests (page 4-9)
■
restoring the factory default configuration (page 4-11)
■
downloading new software to the Series 2600 Switches (page 4-12)
■
HP Customer Support Services (page 4-12)
Basic Troubleshooting Tips
Most problems are caused by the following situations. Check for these items
first when starting your troubleshooting:
■
•
If the connected device is also configured to Auto, the switch will
automatically negotiate both link speed and communication mode.
•
If the connected device has a fixed configuration, for example 100
Mbps, at half or full duplex, the switch will automatically sense the
link speed, but will default to a communication mode of half duplex.
4-1
Troubleshooting
Connecting to devices that have a fixed full-duplex configuration.
The RJ-45 ports are configured as “Auto”. That is, when connecting to
attached devices, the switch operates in one of two ways to determine the
link speed and the communication mode (half duplex or full duplex):
Troubleshooting
Basic Troubleshooting Tips
Caution
Because the Series 2600 Switches behave in this way (in compliance with
the IEEE 802.3 standard), if a device connected to the switch has a fixed
configuration at full duplex, the device will not connect correctly to the
switch. The result will be high error rates and very inefficient communi­
cations between the switch and the device.
Ensure all devices connected to the Series 2600 Switches are configured
to auto negotiate, or are configured to connect at half duplex (all hubs are
configured this way, for example).
■
Faulty or loose cables. Look for loose or obviously faulty connections.
If the cables appear to be OK, make sure the connections are snug. If that
does not correct the problem, try a different cable.
■
Non-standard cables. Non-standard and miswired cables may cause
network collisions and other network problems, and can seriously impair
network performance. Use a new correctly-wired cable or compare your
cable to the cable in appendix B, “Switch Ports and Network Cables” for
pinouts and correct cable wiring. A category 5 cable tester is a
recommended tool for every 100Base-TX and 1000Base-T network
installation.
■
Improper Network Topologies. It is important to make sure you have
a valid network topology. Common topology faults include excessive
cable length and excessive repeater delays between end nodes. If you have
network problems after recent changes to the network, change back to
the previous topology. If you no longer experience the problems, the new
topology is probably at fault. Sample topologies are shown at the end of
chapter 2 in this book, and some topology configuration guidelines can
be found online at the ProCurve Web site, http://www.procurve.com.
In addition, you should make sure that your network topology contains
no data path loops. Between any two end nodes, there should be only
one active cabling path at any time. Data path loops will cause broadcast
storms that will severely impact your network performance.
Troubleshooting
For your Switch, if you wish to build redundant paths between important
nodes in your network to provide some fault tolerance, you should enable
Spanning Tree Protocol support on the switch. This ensures that only
one of the redundant paths is active at any time, thus avoiding data path
loops. Spanning Tree can be enabled through the switch console or the
web browser interface.
The Series 2600 Switches also support Trunking, which allows multiple
network cables to be used for a single network connection without
causing a data path loop. For more information on Spanning Tree and
Trunking, see the Management and Configuration Guide, which is on
the Documentation CD-ROM that came with your switch.
4-2
Troubleshooting
Basic Troubleshooting Tips
■
Check the port configuration. A port on your switch may not be
operating as you expect because it has been put into a “blocking” state by
Spanning Tree, GVRP (automatic VLANs), or LACP (automatic trunking).
(Note that the normal operation of the Spanning Tree, GVRP, and LACP
features may put the port in a blocking state.) Or, the port just may have
been configured as disabled through software.
Use the switch console to determine the port’s configuration and verify
that there is not an improper or undesired configuration of any of the
switch features that may be affecting the port. For more information, see
the Management and Configuration Guide, which is on the Documenta­
tion CD-ROM that came with your switch.
For more information on possible network problems and their solutions, refer
to the technical note “Troubleshooting LAN Performance and Intermittent
Connectivity Problems”, which can be found on the ProCurve Web site,
http://www.procurve.com, in the Reference Library section, A-Z Index.
Troubleshooting
4-3
Troubleshooting
Diagnosing with the LEDs
Diagnosing with the LEDs
Table 4-1 shows LED patterns on the switch and the switch modules that
indicate problem conditions.
1.
Check in the table for the LED pattern you see on your switch.
2.
Refer to the corresponding diagnostic tip on the next few pages.
Table 4-1.
LED Error Indicators
LED Pattern Indicating Problems
Power
Fault
RPS
EPS
Self Test
Fan
Status
(in Link view mode)
Diagnostic
Tips
Off with
power cord
plugged in
1
1
1
1
1
1
➊
On
Prolonged On
1
1
Prolonged On
1
1
➋
On
Blinking2
1
1
Blinking2
1
1
➌
On
Blinking2
1
1
Off
Blinking2
1
➍
On
Blinking2
1
1
Blinking2
1
Blinking2
➎
On
Off
1
1
Off
1
Off with cable
connected
➏
On
Off
1
1
Off
1
On, but the port is not
communicating
➐
On
Blinking
Blinking
Blinking
1
1
➑
1
This LED is not important for the diagnosis.
Troubleshooting
2 The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
4-4
Port LED
Troubleshooting
Diagnosing with the LEDs
Diagnostic Tips:
Problem
Solution
➊
The switch is not
plugged into an
active AC power
source, or the
switch’s power
supply may have
failed.
1. Verify the power cord is plugged into an active power source and to the switch. Make
sure these connections are snug.
2. Try power cycling the switch by unplugging and plugging the power cord back in.
3. If the Power LED is still not on, verify the AC power source works by plugging another
device into the outlet. Or try plugging the switch into a different outlet or try a different
power cord.
If the power source and power cord are OK and this condition persists, the switch power
supply may have failed. Call your HP-authorized LAN dealer, or use the electronic support
services from HP to get assistance. See the Customer Support/Warranty booklet for more
information.
➋
A switch
hardware failure
has occurred. All
the LEDs will stay
on indefinitely.
Try power cycling the switch. If the fault indication reoccurs, the switch may have failed.
Call your HP-authorized LAN dealer, or use the electronic support services from HP to get
assistance. See the Customer Support/Warranty booklet for more information.
➌
The switch has
experienced a
software failure
during self test.
1. Try resetting the switch by pressing the Reset button on the front of the switch, or by
power cycling the switch.
2. If the fault indication reoccurs, attach a console to the switch (as indicated in chapter
2) and configure it to operate at 9600 baud. Then, reset the switch. Messages should
appear on the console screen and in the console log identifying the error condition.
You can view the console log at that point by selecting it from the console Main Menu.
If necessary to resolve the problem, contact your HP-authorized LAN dealer, or use the
electronic support services from HP to get assistance. See the Customer Support/
Warranty booklet for more information.
➍
One or both of the
switch cooling
fans may have
failed.
Try disconnecting power from the switch and wait a few moments. Then reconnect the
power to the switch and check the LEDs again. If the error indication reoccurs, one or
both of the fans has failed. The switch has two fans and may continue to operate under
this condition if the ambient temperature does not exceed normal room temperature, but
for best operation, the switch should be replaced. Contact your HP-authorized LAN dealer,
or use the electronic support services from HP to get assistance. See the Customer
Support/Warranty booklet for more information.
➎
The network port
for which the LED
is blinking has
experienced a
self test or
initialization
failure.
Try power cycling the switch. If the fault indication reoccurs, the switch port may have
failed. Call your HP-authorized LAN dealer, or use the electronic support services from
HP to get assistance. See the Customer Support/Warranty booklet for more information.
If the port is a mini-GBIC, verify that it is one of the mini-GBICs supported by the switch.
Unsupported mini-GBICs will be identified with this fault condition. The supported
mini-GBICs are listed in Chapter 2, “Installing the Switch” on page 2-7. The
mini-GBICs are also tested when they are “hot-swapped”—installed or changed while
the switch is powered on.
To verify that the port has failed, try removing and reinstalling the mini-GBIC without
having to power off the switch. If the port fault indication reoccurs, you will have to
replace the mini-GBIC.
continued on the next page
4-5
Troubleshooting
Tip
Troubleshooting
Diagnosing with the LEDs
Tip
Problem
Solution
➏
The network
connection is not
working
properly.
Try the following procedures:
• For the indicated port, verify that both ends of the cabling, at the switch and the connected device, are connected properly.
• Verify the connected device and switch are both powered on and operating correctly.
• Verify you have used the correct cable type for the connection:
– For twisted-pair connections to the fixed 10/100 or 10/100/1000 ports, if the port is
configured to “Auto” (auto negotiate), either straight-through or crossover cables
can be used because of the switch’s “HP Auto-MDIX” feature and the Auto MDI/
MDI-X feature of the 10/100/1000-T port.
Note: If the switch port configuration is changed to one of the fixed configuration
options (for example, 100 Mbps/Full Duplex), then the port operates as MDI-X only
and you must use the correct type of cable for the connection. In general, for
connecting an end node (MDI port) to the switch, use straight-through cable; for
connecting to MDI-X ports on hubs, other switches, and routers, use crossover
cable.
•
•
•
•
Troubleshooting
•
4-6
– For fiber-optic connections, verify the transmit port on the switch is connected to
the receive port on the connected device, and the switch receive port is connected
to the transmit port on the connected device.
For the dual-personality 10/100/1000-T ports, be sure a mini-GBIC is not installed in the
associated slot.
For 1000Base-T connections, verify the network cabling complies with the IEEE 802.3ab
standard. the cable should be installed according to the ANSI/TIA/EIA-568-A-5
specifications. Cable testing should comply with the stated limitations for Attenuation,
Near-End Crosstalk, Far-End Crosstalk, Equal-Level Far-End Crosstalk (ELFEXT),
Multiple Disturber ELFEXT, and Return Loss.
The cable verification process must include all patch cables from any end devices,
including the switch, to any patch panels in the cabling path.
Verify the port has not been disabled through a switch configuration change. You can
use the console interface, or, if you have configured an IP address on the switch, use
the web browser interface to determine the state of the port and re-enable the port if
necessary.
Verify the switch port configuration matches the configuration of the attached device.
For example, if the switch port is configured as “Auto”, the port on the attached device
also MUST be configured as “Auto”. Depending on the port type, twisted-pair or fiberoptic, if the configurations don’t match, the results could be a very unreliable
connection, or no link at all.
If the other procedures don’t resolve the problem, try using a different port or a different
cable.
Troubleshooting
Diagnosing with the LEDs
Tip
Problem
Solution
➐
The port may be
improperly
configured, or
the port may be in
a “blocking”
state by the
normal operation
of the Spanning
Tree, LACP, or
IGMP features.
Use the switch console to see if the port is part of a dynamic trunk (through the LACP feature) or to see if Spanning Tree is enabled on the switch, and to see if the port may have been put into a “blocking” state by those features. The show lacp command displays
the port status for the LACP feature; the show spanning-tree command displays the port status for Spanning Tree.
Also check the Port Status screen using the show interfaces command to see if the port has been configured as “disabled”.
Other switch features that may affect the port operation include VLANs and IGMP. Use the switch console to see how the port is configured for these features.
For software troubleshooting tips, see the chapter “Troubleshooting” in the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your
switch.
Ensure also, that the device at the other end of the connection is indicating a good link to the switch. If it is not, the problem may be with the cabling between the devices or the connectors on the cable.
➑
RPS or EPS is
connected but
has experienced
a fault.
Refer to the ProCurve 600/610 External Power Supplies documentation.
Troubleshooting
4-7
Troubleshooting
Proactive Networking
Proactive Networking
The ProCurve Series 2600 Switches have built-in management capabilities that
proactively help you manage your network including:
■
finding and helping you fix the most common network error conditions
(for example, faulty network cabling, and non-standard network
topologies)
■
informing you of the problem with clear, easy-to-understand messages
■
recommending network configuration changes to enhance the
performance of your network
The following interfaces provide tests, indicators, and an event log that can
be used to monitor the switch and its network connections and to help you
take advantage of these proactive networking features:
■
A graphical web browser interface you can use to manage your switch
from a PC running a supported web browser, for example Microsoft
Internet Explorer, and Netscape Communicator.
■
A full-featured easy-to-use console interface you can access by connecting
a standard terminal or PC running a terminal emulator to the switch’s
console port. The cable to make that connection is provided with your
switch. The console interface is also accessible through a Telnet
connection.
Troubleshooting
For more information on using these software tools to diagnose and manage
your switch, see the “Troubleshooting” chapter in the Management and
Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
4-8
Troubleshooting
Hardware Diagnostic Tests
Hardware Diagnostic Tests
Testing the Switch by Resetting It
If you believe the switch is not operating correctly, you can reset the switch
to test its circuitry and operating code. To reset a switch, either:
■
unplug and plug in the power cord (power cycling)
■
press the Reset button on the front of the switch
Power cycling the switch and pressing the Reset button both cause the switch
to perform its power-on self test, which almost always will resolve any
temporary operational problems. These reset processes also cause any
network traffic counters to be reset to zero, and cause the System Up Time
timer to reset to zero.
Checking the Switch LEDs
The self test passes if the Fault and Self Test LEDs on the front of the switch
go off after approximately 50 seconds. If these LEDs stay on longer than 60
seconds or begin blinking, there may be a problem with the switch.
See “Diagnosing With the LEDs” on page 4-4 for information on interpreting
the LED patterns.
Checking Console Messages
4-9
Troubleshooting
Useful diagnostic messages may be displayed on the console screen when the
switch is reset. As described in chapter 2 under step 7, Connect a Console to
the Switch connect a PC running a VT-100 terminal emulator program or a
standard VT-100 terminal to the switch’s Console Port and configure it to run
at 9600 baud, and with the other terminal communication settings shown on
“Configuring the Switch”. Then, when you reset the switch, note the messages
that are displayed. Additionally, you can check the switch event log, which
can be accessed from the console using the show log command, or from the
console Main Menu after entering the Menu command.
Troubleshooting
Hardware Diagnostic Tests
Testing Twisted-Pair Cabling
Network cables that fail to provide a link or provide an unreliable link between
the switch and the connected network device may not be compatible with the
IEEE 802.3 Type 10Base-T, 100Base-TX, or 1000Base-T standards. The twistedpair cables attached to the switch must be compatible with the appropriate
standards. To verify your cable is compatible with these standards, use a
qualified cable test device.
Testing Switch-to-Device Network Communications
You can perform the following communication tests to verify the network is
operating correctly between the switch and any connected device that can
respond correctly to the communication test.
■
Link Test—a physical layer test that sends IEEE 802.2 test packets to any
device identified by its MAC address
■
Ping Test—a network layer test used on IP networks that sends test
packets to any device identified by its IP address
These tests can be performed through the switch console interface from a
terminal connected to the switch or through a Telnet connection, or from the
switch’s web browser interface. For more information, see the Management
and Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
Testing End-to-End Network Communications
Troubleshooting
Both the switch and the cabling can be tested by running an end-to-end
communications test—a test that sends known data from one network device
to another through the switch. For example, if you have two PCs on the
network that have LAN adapters between which you can run a link-level test
or Ping test through the switch, you can use this test to verify that the entire
communication path between the two PCs is functioning correctly. See your
LAN adapter documentation for more information on running a link test or
Ping test.
4-10
Troubleshooting
Restoring the Factory Default Configuration
Restoring the Factory Default
Configuration
As part of your troubleshooting process on the Switch, it may become
necessary to return the switch configuration to the factory default settings.
This clears any passwords, clears the console event log, resets the network
counters to zero, performs a complete self test, and reboots the switch into
its factory default configuration including deleting the IP address, if one is
configured.
Note
This process removes all switch configuration changes that you have made
from the factory default settings. This includes, for example, configuration of
VLANs, Spanning Tree, trunks, and stacking. Returning the configuration of
these features to their factory default settings (usually disabling them) may
result in network connectivity issues.
If the switch has a valid configuration, and you are restoring the factory default
settings for a reason other than configuration problems, you should save the
switch configuration prior to performing the factory default reset. Then, after
the reset and resolution of the original problem, you can restore the saved
configuration to the switch. For both the save and restore processes, you can
use the console copy command. For more information on this command, see
the Management and Configuration Guide, which is on the Documentation
CD-ROM that came with your switch.
You can restore the factory default configuration either on the switch itself,
or through the switch console.
To execute the factory default reset on the switch, perform these steps:
1. Using pointed objects, simultaneously press both the Reset and Clear
buttons on the front of the switch. The power and fault lights come on.
2. Continue to press the Clear button while releasing the Reset button.
The switch will then complete its self test and begin operating with its
configuration restored to the factory default settings.
To restore the factory default configuration using the console, execute the
erase startup-config command from the console command prompt.
4-11
Troubleshooting
3. When the Self Test LED begins to blink, release the Clear button.
Troubleshooting
Downloading New Switch Software
Downloading New Switch Software
When product enhancements occur for the Series 2600 Switches, new
software can be downloaded to the switch through several methods, for
product enhancements and new features. For more information, see the
Management and Configuration Guide, which is on the Documentation CD­
ROM that came with your switch.
The new switch software would be available on the ProCurve Web site,
http://www.procurve.com.
HP Customer Support Services
If you are still having trouble with your switch, Hewlett-Packard offers support
24 hours a day, seven days a week through the use of a number of automated
electronic services. See the Customer Support/Warranty booklet that came
with your switch for information on how to use these services to get technical
support. The ProCurve Web site, http://www.procurve.com also provides upto-date support information.
Additionally, your HP-authorized network reseller can provide you with
assistance, both with services that they offer and with services offered by HP.
Before Calling Support
Before calling your networking dealer or HP Support, to make the support
process most efficient, you first should retrieve the following information:
Troubleshooting
Information Item
4-12
Information Location
• product identification, including mini-GBICs
the front of the switch and on
labels on the mini-GBICs
• details about the switch’s status including the
software (OS) version, a copy of the switch
configuration, a copy of the switch Event Log, and a
copy of the switch status and counters information
switch console: show tech
command
• copy of your network topology map, including
network addresses assigned to the relevant devices
your network records
A
Switch Specifications
Switch Specifications
Physical
2600 Non-PWR Series
Width
Depth
Height
Weight
2626 (J4900B)
44.3 cm (17.4 in)
36.7 cm (14.4 in)
4.4 cm (1.73 in)
4.62 kg (10.20 lbs)
2650 (J4899B)
44.3 cm (17.4 in)
43.0 cm (16.9 in)
4.4 cm (1.73 in)
4.88 kg (10.75 lbs)
2600-8-PWR (J8762A)
44.3 cm (17.4 in)
22.5 cm (8.86 in)
4.4 cm (1.73 in)
3.4 kg (7.5 lbs)
2626-PWR (J8164A)
44.3 cm (17.4 in)
48.3 cm (19.0 in)
4.4 cm (1.73 in)
6.84 kg (15.05 lbs)
2650-PWR (J8165A)
44.3 cm (17.4 in)
48.3 cm (19.0 in)
4.4 cm (1.73 in)
7.58 kg (16.70 lbs)
2600-PWR Series
Electrical
2600 Non-PWR Series
AC voltage
Maximum current
Frequency range
2626 (J4900B)
100-240 volts
1.5A
50/60 Hz
2650 (J4899B)
100-240 volts
1.5A
50/60 Hz
2600-8-PWR (J8762A)
100-240 volts
3.3A-1.7A
50/60 Hz
2626-PWR (J8164A)
100-240 volts
7.5A-3.5A
50/60 Hz
2650-PWR (J8165A)
100-240 volts
7.5A-3.5A
50/60 Hz
2600-PWR Series
The switch automatically adjusts to any voltage between 100-240 volts and
either 50 or 60 Hz.
A-1
Switch Specifications
Switch Specifications
Environmental
Non-PWR 2600 Series Operating
Non-Operating
Temperature
0 °C to 55 °C (32 °F to 131 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
Relative humidity
(non-condensing)
15% to 95% at 40 °C (104 °F)
15% to 90% at 65 °C (149 °F)
Maximum altitude
4.6 Km (15,000 ft)
4.6 Km (15,000 ft)
2600-PWR Series
Operating
Non-Operating
Temperature
0 °C to 50 °C (32 °F to 122 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
Relative humidity
(non-condensing)
15% to 95% at 40 °C (104 °F)
15% to 90% at 65 °C (149 °F)
BTU Ratings
Switch Model
Combined BTU1
Switch only BTU
2600-8-PWR
649
228
2626-PWR
2288
921
2650-PWR
2288
921
2626
Non-PoE
341
2650
Non-PoE
341
1 Includes switch and maximum number of PoE powered devices
connected to the switch at 15.4 watts.
Acoustic
Non-PWR 2600 Series (J4899B/J4900B)
Geraeuschemission LwA=50 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=50 dB at virtual work space according to DIN 45635 T.19
2600-PWR Series (J8164A/J8165A)
Geraeuschemission LwA=53 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=53 dB at virtual work space according to DIN 45635 T.19
2600-8-PWR switch (J8762A)
Geraeuschemission LwA=55 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=55 dB at virtual work space according to DIN 45635 T.19
A-2
Switch Specifications
Connectors
The 10/100/1000 Mbps RJ-45 twisted-pair ports are compatible with the
following standards:
•
IEEE 802.3ab 1000Base-T
•
IEEE 802.3u 100Base-TX
•
IEEE 802.3 10Base-T
■
The 1000 Mbps LC fiber-optic ports on the Gigabit-SX and Gigabit-LX miniGBIC transceivers are compatible with the IEEE 802.3z Gigabit-SX and
Gigabit-LX standards.
■
EPS connector: A 2x7 Molex Micro-Fit connector should be used for EPS
connection.
■
RPS connector: A 2x7 connector is provided for external RPS connection
on the power supply module.
Cable Length
■
EPS cables are 2.0 meters (6.56 feet) in length
■
RPS cables are 1.25 meters (4.10 feet) in length
Safety
Complies with:
■
EN60950 / IEC 6095
■
CSA 22.2 No. 950
■
UL 60950
Lasers
The Gigabit-SX LC mini-GBIC, and the Gigabit-LX LC mini-GBIC, both of
which can be installed in the Series 2600 Switches, are Class 1 Laser Products.
Laser Klasse 1
These mini-GBICs comply with IEC 60825.
A-3
Switch Specifications
■
— This page is intentionally unused. —
B
Switch Ports and Network Cables
This appendix includes switch connector information and network cable
information for cables that should be used with the Switch 2600 and 2600-PWR
Series devices, including minimum pin-out information and specifications for
twisted-pair cables.
Incorrectly wired cabling is the most common cause of problems for LAN
communications. HP recommends that you work with a qualified LAN cable
installer for assistance with your cabling requirements.
Switch Ports
The fixed RJ-45 10/100/1000Base-T ports on the switch accept 100-ohm
unshielded and shielded twisted-pair cable with RJ-45 connectors as
described on the next page.
Twisted-Pair Cables
10 Mbps Operation
Category 3, 4, or 5 100-ohm unshielded twisted-pair (UTP)
or shielded twisted-pair (STP) cable, complying with IEEE
802.3 Type 10Base-T specifications, fitted with RJ-45
connectors
100 Mbps Operation
Category 5 100-ohm UTP or STP cable, complying with
IEEE 802.3u 100Base-TX specifications, fitted with RJ-45
connectors
1000 Mbps Operation Category 5 100-ohm 4-pair UTP or STP cable, complying
with IEEE 802.3ab 1000Base-T specifications, fitted with
RJ-45 connectors—Category 5e or better is recommended
(please see “Note on 1000Base-T Cable Requirements”,
below)
Note on 1000Base-T Cable Requirements. The Category 5 networking
cables that work for 100Base-TX connections should also work for
1000Base-T, as long as all four-pairs are connected. But, for the most robust
connections you should use cabling that complies with the Category 5e
specifications, as described in Addendum 5 to the TIA-568-A standard (ANSI/
TIA/EIA-568-A-5).
B-1
Switch Ports and Network
Cables
Note
Switch Ports and Network Cables
Because of the increased speed provided by 1000Base-T (Gigabit-T), network
cable quality is more important than for either 10Base-T or 100Base-TX.
Cabling plants being used to carry 1000Base-T networking must comply with
the IEEE 802.3ab standards. In particular, the cabling must pass tests for
Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT).
Additionally, unlike the cables for 100Base-TX, the 1000Base-T cables must
pass tests for Equal-Level Far-End Crosstalk (ELFEXT) and Return Loss.
Switch Ports and Network
Cables
When testing your cabling, be sure to include the patch cables that connect
the switch and other end devices to the patch panels on your site. The patch
cables are frequently overlooked when testing cable and they must also
comply with the cabling standards.
Fiber-Optic Cables
Port Type
Cable Specifications
Connector Type
Maximum Length
Gigabit-SX
62.5/125 mm or 50/125 µm (core/cladding)
diameter, graded-index, 850 nm, low metal
content, multimode fiber-optic cables,
complying with the ITU-T G.651 and ISO/IEC
793-2 Type A1b or A1a respectively.
LC - Gigabit-SX
mini-GBIC
• 62.5 µm cable:
– 160 MHz*Km=220 meters
– 200 MHz*Km=275 meters
• 50 µm cable:
– 400 MHz*Km=500 meters
– 500 MHz*Km=550 meters
Gigabit-LX
9/125 µm (core/cladding) diameter, gradedindex, 1310 nm, low metal content, single
mode fiber-optic cables, complying with the
ITU-T G.652 and ISO/IEC 793-2 Type B1
standards.
OR
the multimode fiber-optic cables listed for
Gigabit-SX.
LC - Gigabit-LX
mini-GBIC
• Single-mode cable:
10 kilometers
• Multimode cable:
550 meters
Note: To use multimode cables for Gigabit-LX, a mode conditioning patch cord may be needed - See
“Mode Conditioning Patch Cord for Gigabit-LX” on page B-3 for more information.
Gigabit-LH
9/125 mm (core/cladding) diameter, gradedindex, 1550 nm, low metal content, single
mode fiber-optic cables, complying with the
ITU-T G.652 and ISO/IEC 793-2 Type B1
standards.
LC - Gigabit-LH
mini-GBIC
70 kilometers
Note: Between the transmit and receive ends of the cable, at least 5db of attenuation is required for a
reliable connection. This is equivalent to 20 Km of the fiber-optic cable. For distances less than 20 Km,
you must add attenuators to bring the total attenuation to at least 5db. Most cable vendors carry
attenuators.
B-2
Switch Ports and Network Cables
Mode Conditioning Patch Cord for Gigabit-LX
Mode Conditioning Patch Cord for
Gigabit-LX
The following information applies to installations in which multimode fiberoptic cables are connected to a Gigabit-LX port.
Gigabit-LX mini-GBICs, since they are designed to operate with both singlemode and multimode cable, do not provide the transmission conditioning
internally. Thus, under certain circumstances, depending on the cable used
and the lengths of the cable runs, an external Mode Conditioning Patch
Cord may need to be installed between the Gigabit-LX transmitting device
and the multimode network cable to provide the transmission conditioning.
If you experience a high number of transmission errors on the Gigabit-LX
ports, usually CRC or FCS errors, you may need to install one of these patch
cords between the Gigabit-LX port in your switch and your multimode fiberoptic network cabling, and between the Gigabit-LX transmission device and
the network cabling at the other end of the multimode fiber-optic cable run.
A patch cord must be installed at both ends.
The patch cord consists of a short length of single-mode fiber cable coupled
to graded-index multimode fiber cable on the transmit side, and only
multimode cable on the receive side. The section of single-mode fiber is
connected in such a way that it minimizes the effects of the differential mode
delay in the multimode cable.
Note
Most of the time, if you are using good quality graded-index multimode fiber
cable that adheres to the standards listed on page 2-6, there should not be a
need to use mode conditioning patch cords in your network. This is especially
true if the fiber runs in your network are relatively short.
If you are using single-mode fiber-optic cabling in your network, there is no
need to use mode conditioning patch cords. Connect the single-mode network
cable directly to the Gigabit-LX mini-GBIC.
B-3
Switch Ports and Network
Cables
Unlike Gigabit-SX, which connects to only multimode fiber-optic cabling,
Gigabit-LX can use either single-mode or multimode cable. Multimode cable
has a design characteristic called “Differential Mode Delay”, which requires
that the transmission signals be “conditioned” to compensate for the cable
design and thus prevent resulting transmission errors. Since Gigabit-SX is
designed to operate only with multimode cable, Gigabit-SX mini-GBICs can
provide that transmission conditioning internally.
Switch Ports and Network Cables
Mode Conditioning Patch Cord for Gigabit-LX
Installing the Patch Cord
As shown in the illustration below, connect the patch cord to the Gigabit-LX
mini-GBIC with the section of single-mode fiber plugged in to the Tx (transmit)
port. Then, connect the other end of the patch cord to your network cabling
patch panel, or directly to the network multimode fiber.
If you connect the patch cord directly to the network cabling, you may need
to install a female-to-female adapter to allow the cables to be connected
together.
To network
multimode
cabling
The multimode cable in the patch cord
must match the characteristics of your
network cable
Tx
Rx
Switch Ports and Network
Cables
Gigabit-LX port
LC Connector
Mode Conditioning
Patch Cord
Single-mode section plugs into Tx
port on Gigabit-LX Transceiver or
Gigabit-LX mini-GBIC
Make sure you purchase a patch cord that has LC connectors on the end that
connects to the Gigabit-LX mini-GBIC, and has multimode fibers that match
the characteristics of the multimode fiber in your network.
B-4
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Twisted-Pair Cable/Connector Pin-Outs
The HP Auto-MDIX Feature: In the default configuration, “Auto”, the
fixed 10/100Base-TX ports on the Series 2600 Switches all automatically detect
the type of port on the connected device and operate as either an MDI or
MDI-X port, whichever is appropriate. So for any connection, a straightthrough twisted-pair cable can be used—you no longer have to use crossover
cables, although crossover cables can also be used for any of the connections.
(The 10/100/1000-T ports support the IEEE 802.3ab standard, which includes
the “Auto MDI/MDI-X” feature, which operates the same way.)
If you happen to use a correctly wired crossover cable, though, the switch will
still be able to automatically detect the MDI/MDI-X operation and link
correctly to the connected device.
Note
Using Fixed Configurations. If the port configuration is changed to any of
the fixed configurations though, for example 100 Mbps/full duplex, the port
operates as MDI-X only and the correct cable type must be used: for
connections to MDI ports, such as end nodes, use a straight-through cable; for
connections to MDI-X ports, such as on hubs and other switches, use a
crossover cable.
Other Wiring Rules:
■
All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-B (not USOC). See “Twisted-Pair Cable Pin
Assignments” later in this appendix for a listing of the signals used on each
pin.
■
For 1000Base-T connections, all four pairs of wires in the cable must be
available for data transmission. See “Note on 1000Base-T Cable Require­
ments” on page B-1 for more information on 1000Base-T cabling.
■
For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
unshielded twisted-pair cable, as supported by the IEEE 802.3 Type
10Base-T standard.
B-5
Switch Ports and Network
Cables
If you connect a Series 2600 or 2600-PWR Switch twisted-pair port to another
switch or hub, which typically have MDI-X ports, the Series 2600 Switch’s port
automatically operates as an MDI port. If you connect it to an end node, such
as a server or PC, which typically have MDI ports, the Series 2600 Switch’s
port operates as an MDI-X port. In all cases, you can use standard straightthrough cables or crossover cables.
Switch Ports and Network
Cables
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
B-6
■
For 100 Mbps connections to the ports, use 100-ohm Category 5 UTP or
STP cable only, as supported by the IEEE 802.3u Type 100Base-TX
standard.
■
For 1000 Mbps connections, 100-ohm Category 5e or better cabling is
recommended.
■
To provide Power over Ethernet to the access point, all 4 pairs must be
connected for any network cable attached to this port; the cable must
meet ISO/DIS 11801 Class D requirements and IEEE 802.3af requirements.
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Straight-through Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connections
Because of the HP Auto-MDIX operation of the 10/100 ports on the switch, for
all network connections, to PCs, servers or other end nodes, or to hubs or
other switches, you can use straight-through cables.
If any of these ports are given a fixed configuration, for example 100 Mbps/
Full Duplex, the ports operate as MDI-X ports, and straight-through cables
must be then used for connections to PC NICs and other MDI ports.
Cable Diagram
Switch Ports and Network
Cables
Note
Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired
in the cable.
.
Pin Assignments
Switch End (MDI-X)
Computer, Transceiver, or
Other End
Signal
Pins
Pins
Signal
receive +
receive transmit +
transmit -
1
2
3
6
1
2
3
6
transmit +
transmit ­
receive +
receive ­
B-7
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Crossover Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connection
The HP Auto-MDIX operation of the 10/100 ports on the switch also allows
you to use crossover cables for all network connections, to PCs, servers or
other end nodes, or to hubs or other switches.
If any of these ports are given a fixed configuration, for example 100 Mbps/
Full Duplex, the ports operate as MDI-X ports, and crossover cables must be
then used for connections to hubs or switches or other MDI-X network
devices.
Switch Ports and Network
Cables
Cable Diagram
Note
Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired
in the cable.
Pin Assignments
B-8
Switch End (MDI-X)
Hub or Switch Port, or Other
MDI-X Port End
Signal
Pins
Pins
Signal
receive +
receive transmit +
transmit -
1
2
3
6
6
3
2
1
transmit ­
transmit +
receive ­
receive +
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Straight-Through Twisted-Pair Cable for
1000 Mbps Network Connections
1000Base-T connections require that all four pairs of wires be connected.
Cable Diagram
Switch Ports and Network
Cables
Note
Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 4 and 5 on connector “A” must be wired as a twisted pair to pins 4 and 5
on connector “B”.
Pins 7 and 8 on connector “A” must be wired as a twisted pair to pins 7 and 8
on connector “B”.
.
Pin Assignments
For 1000Base-T operation, all four pairs of wires are used for both transmit
and receive.
B-9
— This page is intentionally unused. —
C
Safety and EMC Regulatory Statements
Safety Information
!
Documentation reference symbol. If the product is marked with this
symbol, refer to the product documentation to get more information
about the product.
WARNING
A WARNING in the manual denotes a hazard that can cause injury
or death.
Caution
A Caution in the manual denotes a hazard that can damage equip­
ment.
Do not proceed beyond a WARNING or Caution notice until you
have understood the hazardous conditions and have taken appro­
priate steps.
For LAN cable grounding:
■
If your LAN covers an area served by more than one power distribu­
tion system, be sure their safety grounds are securely interconnected.
■
LAN cables may occasionally be subject to hazardous transient volt­
ages (such as lightning or disturbances in the electrical utilities power
grid). Handle exposed metal components of the network with caution.
Servicing
There are no user-serviceable parts inside these products. Any servicing,
adjustment, maintenance, or repair must be performed only by service-trained
personnel.
These products do not have a power switch; they are powered on when the
power cord is plugged in.
C-1
Safety and EMC Regulatory
Statements
Grounding
These are safety class I products and have protective earthing terminals. There
must be an uninterruptible safety earth ground from the main power source
to the product's input wiring terminals, power cord, or supplied power cord
set. Whenever it is likely that the protection has been impaired, disconnect
the power cord until the ground has been restored.
Safety and EMC Regulatory Statements
Informations concernant la sécurité
Informations concernant la sécurité
!
Symbole de référence à la documentation. Si le produit est marqué de
ce symbole, reportez-vous à la documentation du produit afin d'obtenir
des informations plus détaillées.
WARNING
Dans la documentation, un WARNING indique un danger susceptible
d'entraîner des dommages corporels ou la mort.
Caution
Un texte de mise en garde intitulé Caution indique un danger suscep­
tible de causer des dommages à l'équipement.
Ne continuez pas au-delà d'une rubrique WARNING ou Caution avant
d'avoir bien compris les conditions présentant un danger et pris les
mesures appropriées.
Cet appareil est un produit de classe I et possède une borne de mise à la terre. La source
d'alimentation principale doit être munie d'une prise de terre de sécurité installée aux
bornes du câblage d'entrée, sur le cordon d'alimentation ou le cordon de raccordement
fourni avec le produit. Lorsque cette protection semble avoir été endommagée,
débrancher le cordon d'alimentation jusqu'à ce que la mise à la terre ait été réparée.
Safety and EMC Regulatory
Statements
Mise à la terre du câble de réseau local:
■
si votre réseau local s'étend sur une zone desservie par plus d'un système de
distribution de puissance, assurez-vous que les prises de terre de sécurité
soient convenablement interconnectées.
■
Les câbles de réseaux locaux peuvent occasionnellement être soumis à des
surtensions transitoires dangereuses (telles que la foudre ou des perturba­
tions dans le réseau d'alimentation public). Manipulez les composants
métalliques du réseau avec précautions.
Aucune pièce contenue à l'intérieur de ce produit ne peut être réparée par l'utilisateur.
Tout dépannage, réglage, entretien ou réparation devra être confié exclusivement à un
personnel qualifié.
Cet appareil ne comporte pas de commutateur principal ; la mise sous tension est
effectuée par branchement du cordon d'alimentation.
C-2
Safety and EMC Regulatory Statements
Hinweise zur Sicherheit
Hinweise zur Sicherheit
!
Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem
Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation
nach, um mehr Informationen über das Produkt zu erhalten.
WARNING
Eine WARNING in der Dokumentation symbolisiert eine Gefahr, die
Verletzungen oder sogar Todesfälle verursachen kann.
Caution
Caution in der Dokumentation symbolisiert eine Gefahr, die dis Gerät
beschädigen kann.
Fahren Sie nach dem Hinweis WARNING oder Caution erst fort,
nachdem Sie den Gefahrenzustand verstanden und die entsprech­
enden Maßnahmen ergriffen haben.
Dies ist ein Gerät der Sicherheitsklasse I und verfügt über einen schützenden Erdung­
sterminal. Der Betrieb des Geräts erfordert eine ununterbrochene Sicherheitserdung
von der Hauptstromquelle zu den Geräteingabeterminals, den Netzkabeln oder dem
mit Strom belieferten Netzkabelsatz voraus. Sobald Grund zur Annahme besteht, daß
der Schutz beeinträchtigt worden ist, das Netzkabel aus der Wandsteckdose herausz­
iehen, bis die Erdung wiederhergestellt ist.
■
Wenn Ihr LAN ein Gebiet umfaßt, das von mehr als einem Stromverteilungs­
system beliefert wird, müssen Sie sich vergewissern, daß die
Sicherheitserdungen fest untereinander verbunden sind.
■
LAN-Kabel können gelegentlich gefährlichen Übergangsspannungen aus­
gesetzt werden (beispielsweise durch Blitz oder Störungen in dem
Starkstromnetz des Elektrizitätswerks). Bei der Handhabung exponierter
Metallbestandteile des Netzwerkes Vorsicht walten lassen.
Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile. Wartungs-,
Anpassungs-, Instandhaltungs- oder Reparaturarbeiten dürfen nur von geschultem
Bedienungspersonal durchgeführt werden.
Dieses Gerät hat keinen Netzschalter; es wird beim Anschließen des Netzkabels
eingeschaltet.
C-3
Safety and EMC Regulatory
Statements
Für LAN-Kabelerdung:
Safety and EMC Regulatory Statements
Considerazioni sulla sicurezza
Considerazioni sulla sicurezza
!
Simbolo di riferimento alla documentazione. Se il prodotto è contras­
segnato da questo simbolo, fare riferimento alla documentazione sul
prodotto per ulteriori informazioni su di esso.
WARNING
La dicitura WARNINGdenota un pericolo che può causare lesioni o
morte.
Caution
La dicituraCaution denota un pericolo che può danneggiare le attrez­
zature.
Non procedere oltre un avviso di WARNING o di Cautionprima di aver
compreso le condizioni di rischio e aver provveduto alle misure del
caso.
Questo prodotto è omologato nella classe di sicurezza I ed ha un terminale protettivo
di collegamento a terra. Dev'essere installato un collegamento a terra di sicurezza, non
interrompibile che vada dalla fonte d'alimentazione principale ai terminali d'entrata,
al cavo d'alimentazione oppure al set cavo d'alimentazione fornito con il prodotto.
Ogniqualvolta vi sia probabilità di danneggiamento della protezione, disinserite il cavo
d'alimentazione fino a quando il collegaento a terra non sia stato ripristinato.
Safety and EMC Regulatory
Statements
Per la messa a terra dei cavi LAN:
■
se la vostra LAN copre un'area servita da più di un sistema di distribuzione
elettrica, accertatevi che i collegamenti a terra di sicurezza siano ben collegati
fra loro;
■
i cavi LAN possono occasionalmente andare soggetti a pericolose tensioni
transitorie (ad esempio, provocate da lampi o disturbi nella griglia d'alimentazione della società elettrica); siate cauti nel toccare parti esposte in metallo
della rete.
Nessun componente di questo prodotto può essere riparato dall'utente. Qualsiasi
lavoro di riparazione, messa a punto, manutenzione o assistenza va effettuato esclusi­
vamente da personale specializzato.
Questo apparato non possiede un commutatore principale; si mette scotto tensione
all'inserirsi il cavo d'alimentazione.
C-4
Safety and EMC Regulatory Statements
Consideraciones sobre seguridad
Consideraciones sobre seguridad
!
Símbolo de referencia a la documentación. Si el producto va
marcado con este símbolo, consultar la documentación del
producto a fin de obtener mayor información sobre el producto.
WARNING
Una WARNING en la documentación señala un riesgo que podría
resultar en lesiones o la muerte.
Caution
Una Caution en la documentación señala un riesgo que podría
resultar en averías al equipo.
No proseguir después de un símbolo de WARNING o Caution hasta
no haber entendido las condiciones peligrosas y haber tomado las
medidas apropiadas.
Este aparato se enmarca dentro de la clase I de seguridad y se encuentra protegido por
una borna de puesta a tierra. Es preciso que exista una puesta a tierra continua desde
la toma de alimentación eléctrica hasta las bornas de los cables de entrada del aparato,
el cable de alimentación o el juego de cable de alimentación suministrado. Si existe la
probabilidad de que la protección a tierra haya sufrido desperfectos, desenchufar el
cable de alimentación hasta haberse subsanado el problema.
■
Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una
red de distribución de electricidad, cerciorarse de que las puestas a tierra
estén conectadas entre sí de modo seguro.
■
Es posible que los cables de la LAN se vean sometidos de vez en cuando a
voltajes momentáneos que entrañen peligro (rayos o alteraciones en la red
de energía eléctrica). Manejar con precaución los componentes de metal de
la LAN que estén al descubierto.
Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario.
Todas las reparaciones, ajustes o servicio de mantenimiento debe realizarlos solamente el técnico.
Este producto no tiene interruptor de potencia; se activa cuando se enchufa el cable
de alimentación.
C-5
Safety and EMC Regulatory
Statements
Puesta a tierra del cable de la red local (LAN):
Safety and EMC Regulatory Statements
Safety Information (Japan)
Safety and EMC Regulatory
Statements
Safety Information (Japan)
Japan Power
Cord Warning
C-6
Safety and EMC Regulatory Statements
Safety Information (China)
Safety Information (China)
Safety and EMC Regulatory
Statements
C-7
Safety and EMC Regulatory Statements
EMC Regulatory Statements
EMC Regulatory Statements
U.S.A.
FCC Class A
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against interference when the
equipment is operated in a commercial environment. This equipment gener­
ates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause interference to
radio communications. Operation of this equipment in a residential area may
cause interference in which case the user will be required to correct the
interference at his own expense.
Canada
This product complies with Class A Canadian EMC requirements.
Safety and EMC Regulatory
Statements
Australia/New Zealand
This product complies with Australia/New Zealand EMC Class A
requirements.
Japan
VCCI Class A
C-8
Safety and EMC Regulatory Statements
EMC Regulatory Statements
Korea
Taiwan
Safety and EMC Regulatory
Statements
C-9
Safety and EMC Regulatory Statements
EMC Regulatory Statements
European Community
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN45014
Manufacturer's Name:
Hewlett-Packard Company
Manufacturer's Address: 8000 Foothills Blvd
Roseville, CA 95747-5502
U.S.A.
declares that the product:
Product Name: HP ProCurve Switch 2650,
HP ProCurve Switch 2626
Model Numbers: J4899A, J4899B; J4900A, J4900B
Accessories: J4858A, J4859A, J4860A
Regulatory Model Number: RSVLC-0204
conforms to the following Product Specifications:
Safety and EMC Regulatory
Statements
Safety: EN60950 (1992) +A1,A2,A3,A4,A11 / IEC 950 (1991) +A1,A2,A3,A4
EN60825-1 (1994) +A11 (1996) / IEC 825-1 (1993), Class 1
EMC:
EN 55022 (1998) / CISPR-22 (1997) Class A
EN55024 (1998) / CISPR-24 (1997)
EN 61000-3-2 (2000) / IEC 61000-3-2 (2000)
EN 61000-3-3 (1995) / IEC 61000-3-3 (1994)
Harmonics
Flicker
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage
Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE
marking accordingly.
Tested with Hewlett-Packard Co. products only.
Mike Avery,
Regulatory Engineering Manager
Roseville, April 18, 2004
European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH,
Department TRE, Herrenberger Strasse 140, D-71034 Böblingen (FAX:+49-7031-14-3143).
C-10
Safety and EMC Regulatory Statements
EMC Regulatory Statements
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN45014
Manufacturer's Name: Hewlett-Packard Company
Manufacturer's Address: 8000 Foothills Blvd
Roseville, CA 95747-5502
U.S.A.
declares that the product:
Product Name: ProCurve Switch 2626-PWR
ProCurve Switch 2650-PWR
ProCurve Switch 2600-8-PWR
Model Number: J8164A, J8165A, J8762A, J8169A1
Accessories: J4858A, J4859A, J4860A, J8168A.
Regulatory Model Number: RSVLC-0302, RSVLC-0504
conforms to the following Product Specifications:
EN60950:2000 / IEC 60950:1999
EN60825-2:2000 / EN60825-1 1994+A1+A2 Laser Class 1
EMC:
EN 55022 (1998) / CISPR-22 (1997) Class A
EN55024 +A1(2001) / CISPR-24 (1997) +A1(2001)
EN 61000-3-2 (2000) / IEC 61000-3-2 (2000) - Harmonics EN 61000-3-3 +A1 (2001) / IEC 61000-3-3 +A1(2001) - Flicker Safety and EMC Regulatory
Statements
Safety:
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE marking accordingly. 1) J8169A for use with ProCurve Switch 2626-PWR, 2650-PWR, and RSVLC-0302
Tested with Hewlett-Packard Co. products only. Roseville,
July 28, 2005 Mike Avery, Regulatory Engineering Manager European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department TRE,
Herrenberger Strasse 140, D-71034 Böblingen (FAX:+49-7031-14-3143).
C-11
Safety and EMC Regulatory Statements
Waste Electrical and Electronic Equipment (WEEE) Statements
Waste Electrical and Electronic Equipment (WEEE) Statements
Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with
your other household waste. Instead, it is your responsibility to dispose of your waste equipment by
handing it over to a designated collection point for the recycling of waste electrical and electronic
equipment. The separate collection and recycling of your waste equipment at the time of disposal will
help to conserve natural resources and ensure that it is recycled in a manner that protects human health
and the environment. For more information about where you can drop off your waste equipment for
recycling, please contact your local city office, your household waste disposal service or the shop where
you purchased the product.
Safety and EMC Regulatory
Statements
Likvidace zařízení soukromými domácími uživateli v Evropské unii
Tento symbol na produktu nebo balení označuje výrobek, který nesmí být vyhozen spolu s ostatním
domácím odpadem. Povinností uživatele je předat takto označený odpad na předem určené sběrné
místo pro recyklaci elektrických a elektronických zařízení. Okamžité třídění a recyklace odpadu
pomůže uchovat přírodní prostředí a zajistí takový způsob recyklace, který ochrání zdraví a životní
prostředí člověka. Další informace o možnostech odevzdání odpadu k recyklaci získáte na
příslušném obecním nebo městském úřadě, od firmy zabývající se sběrem a svozem odpadu nebo v
obchodě, kde jste produkt zakoupili.
Bortskaffelse af affald fra husstande i den Europæiske Union
Hvis produktet eller dets emballage er forsynet med dette symbol, angiver det, at produktet ikke må
bortskaffes med andet almindeligt husholdningsaffald. I stedet er det dit ansvar at bortskaffe kasseret
udstyr ved at aflevere det på den kommunale genbrugsstation, der forestår genvinding af kasseret
elektrisk og elektronisk udstyr. Den centrale modtagelse og genvinding af kasseret udstyr i forbindelse
med bortskaffelsen bidrager til bevarelse af naturlige ressourcer og sikrer, at udstyret genvindes på en
måde, der beskytter både mennesker og miljø. Yderligere oplysninger om, hvor du kan aflevere kasseret
udstyr til genvinding, kan du få hos kommunen, den lokale genbrugsstation eller i den butik, hvor du købte
produktet.
Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus
See tootel või selle pakendil olev sümbol näitab, et kõnealust toodet ei tohi koos teiste majapidamisjäät­
metega kõrvaldada. Teie kohus on oma seadmete jäätmed kõrvaldada, viies need elektri- ja elektrooni­
kaseadmete jäätmete ringlussevõtmiseks selleks ettenähtud kogumispunkti. Seadmete jäätmete eraldi
kogumine ja ringlussevõtmine kõrvaldamise ajal aitab kaitsta loodusvarasid ning tagada, et ringlussev­
õtmine toimub viisil, mis kaitseb inimeste tervist ning keskkonda. Lisateabe saamiseks selle kohta, kuhu
oma seadmete jäätmed ringlussevõtmiseks viia, võtke palun ühendust oma kohaliku linnakantselei,
majapidamisjäätmete kõrvaldamise teenistuse või kauplusega, kust Te toote ostsite.
C-12
Safety and EMC Regulatory Statements
Waste Electrical and Electronic Equipment (WEEE) Statements
Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella
Jos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa hävittää kotitalousjätteiden mukana.
Tällöin hävitettävä laite on toimitettava sähkölaitteiden ja elektronisten laitteiden kierrätyspisteeseen.
Hävitettävien laitteiden erillinen käsittely ja kierrätys auttavat säästämään luonnonvaroja ja
varmistamaan, että laite kierrätetään tavalla, joka estää terveyshaitat ja suojelee luontoa. Lisätietoja
paikoista, joihin hävitettävät laitteet voi toimittaa kierrätettäväksi, saa ottamalla yhteyttä jätehuoltoon tai
liikkeeseen, josta tuote on ostettu.
Élimination des appareils mis au rebut par les ménages dans l'Union européenne
Le symbole apposé sur ce produit ou sur son emballage indique que ce produit ne doit pas être jeté avec
les déchets ménagers ordinaires. Il est de votre responsabilité de mettre au rebut vos appareils en les
déposant dans les centres de collecte publique désignés pour le recyclage des équipements électriques
et électroniques. La collecte et le recyclage de vos appareils mis au rebut indépendamment du reste
des déchets contribue à la préservation des ressources naturelles et garantit que ces appareils seront
recyclés dans le respect de la santé humaine et de l'environnement. Pour obtenir plus d'informations
sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités
locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous
avez acheté ce produit.
Entsorgung von Altgeräten aus privaten Haushalten in der EU
Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin, dass das Produkt nicht über den
normalen Hausmüll entsorgt werden darf. Benutzer sind verpflichtet, die Altgeräte an einer Rücknah­
mestelle für Elektro- und Elektronik-Altgeräte abzugeben. Die getrennte Sammlung und ordnungs­
gemäße Entsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei und garantiert
eine Wiederverwertung, die die Gesundheit des Menschen und die Umwelt schützt. Informationen dazu,
wo Sie Rücknahmestellen für Ihre Altgeräte finden, erhalten Sie bei Ihrer Stadtverwaltung, den örtlichen
Müllentsorgungsbetrieben oder im Geschäft, in dem Sie das Gerät erworben haben
Készülékek magánháztartásban történő selejtezése az Európai Unió területén
A készüléken, illetve a készülék csomagolásán látható azonos szimbólum annak jelzésére szolgál,
hogy a készülék a selejtezés során az egyéb háztartási hulladéktól eltérő módon kezelendő. A
vásárló a hulladékká vált készüléket köteles a kijelölt gyűjtőhelyre szállítani az elektromos és
elektronikai készülékek újrahasznosítása céljából. A hulladékká vált készülékek selejtezéskori
begyűjtése és újrahasznosítása hozzájárul a természeti erőforrások megőrzéséhez, valamint
biztosítja a selejtezett termékek környezetre és emberi egészségre nézve biztonságos feldolgozását.
A begyűjtés pontos helyéről bővebb tájékoztatást a lakhelye szerint illetékes önkormányzattól, az
illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat.
C-13
Safety and EMC Regulatory
Statements
Απόρριψη άχρηστου εξοπλισµού από χρήστες σε ιδιωτικά νοικοκυριά στην Ευρωπαϊκή
Ένωση
Το σύµβολο αυτό στο προϊόν ή τη συσκευασία του υποδεικνύει ότι το συγκεκριµένο προϊόν δεν
πρέπει να διατίθεται µαζί µε τα άλλα οικιακά σας απορρίµµατα. Αντίθετα, είναι δική σας ευθύνη να
απορρίψετε τον άχρηστο εξοπλισµό σας παραδίδοντάς τον σε καθορισµένο σηµείο συλλογής για την
ανακύκλωση άχρηστου ηλεκτρικού και ηλεκτρονικού εξοπλισµού. Η ξεχωριστή συλλογή και
ανακύκλωση του άχρηστου εξοπλισµού σας κατά την απόρριψη θα συµβάλει στη διατήρηση των
φυσικών πόρων και θα διασφαλίσει ότι η ανακύκλωση γίνεται µε τρόπο που προστατεύει την
ανθρώπινη υγεία και το περιβάλλον. Για περισσότερες πληροφορίες σχετικά µε το πού µπορείτε να
παραδώσετε τον άχρηστο εξοπλισµό σας για ανακύκλωση, επικοινωνήστε µε το αρµόδιο τοπικό
γραφείο, την τοπική υπηρεσία διάθεσης οικιακών απορριµµάτων ή το κατάστηµα όπου αγοράσατε το
προϊόν.
Safety and EMC Regulatory Statements
Waste Electrical and Electronic Equipment (WEEE) Statements
Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea
Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere
smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le apparecchiature consegnan­
dole presso un punto di raccolta designato al riciclo e allo smaltimento di apparecchiature elettriche ed
elettroniche. La raccolta differenziata e il corretto riciclo delle apparecchiature da smaltire permette di
proteggere la salute degli individui e l'ecosistema. Per ulteriori informazioni relative ai punti di raccolta
delle apparecchiature, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il
quale è stato acquistato il prodotto.
Nolietotu iekārtu iznīcināšanas noteikumi lietotājiem Eiropas Savienības privātajās
mājsaimniecībās
Šāds simbols uz izstrādājuma vai uz tā iesaiņojuma norāda, ka šo izstrādājumu nedrīkst izmest kopā ar
citiem sadzīves atkritumiem. Jūs atbildat par to, lai nolietotās iekārtas tiktu nodotas speciāli iekārtotos
punktos, kas paredzēti izmantoto elektrisko un elektronisko iekārtu savākšanai otrreizējai pārstrādei.
Atsevišķa nolietoto iekārtu savākšana un otrreizējā pārstrāde palīdzēs saglabāt dabas resursus un
garantēs, ka šīs iekārtas tiks otrreizēji pārstrādātas tādā veidā, lai pasargātu vidi un cilvēku veselību.
Lai uzzinātu, kur nolietotās iekārtas var izmest otrreizējai pārstrādei, jāvēršas savas dzīves vietas
pašvaldībā, sadzīves atkritumu savākšanas dienestā vai veikalā, kurā izstrādājums tika nopirkts.
Safety and EMC Regulatory
Statements
Vartotojų iš privačių namų ūkių įrangos atliekų šalinimas Europos Sąjungoje
Šis simbolis ant gaminio arba jo pakuotės rodo, kad šio gaminio šalinti kartu su kitomis namų ūkio
atliekomis negalima. Šalintinas įrangos atliekas privalote pristatyti į specialią surinkimo vietą elektros ir
elektroninės įrangos atliekoms perdirbti. Atskirai surenkamos ir perdirbamos šalintinos įrangos atliekos
padės saugoti gamtinius išteklius ir užtikrinti, kad jos bus perdirbtos tokiu būdu, kuris nekenkia žmonių
sveikatai ir aplinkai. Jeigu norite sužinoti daugiau apie tai, kur galima pristatyti perdirbtinas įrangos
atliekas, kreipkitės į savo seniūniją, namų ūkio atliekų šalinimo tarnybą arba parduotuvę, kurioje
įsigijote gaminį.
Verwijdering van afgedankte apparatuur door privé-gebruikers in de Europese Unie
Dit symbool op het product of de verpakking geeft aan dat dit product niet mag worden gedeponeerd bij
het normale huishoudelijke afval. U bent zelf verantwoordelijk voor het inleveren van uw afgedankte
apparatuur bij een inzamelingspunt voor het recyclen van oude elektrische en elektronische apparatuur.
Door uw oude apparatuur apart aan te bieden en te recyclen, kunnen natuurlijke bronnen worden
behouden en kan het materiaal worden hergebruikt op een manier waarmee de volksgezondheid en het
milieu worden beschermd. Neem contact op met uw gemeente, het afvalinzamelingsbedrijf of de winkel
waar u het product hebt gekocht voor meer informatie over inzamelingspunten waar u oude apparatuur
kunt aanbieden voor recycling.
Pozbywanie się zużytego sprzętu przez użytkowników w prywatnych gospodarstwach
domowych w Unii Europejskiej
Ten symbol na produkcie lub jego opakowaniu oznacza, że produktu nie wolno wyrzucać do zwykłych
pojemników na śmieci. Obowiązkiem użytkownika jest przekazanie zużytego sprzętu do
wyznaczonego punktu zbiórki w celu recyklingu odpadów powstałych ze sprzętu elektrycznego i
elektronicznego. Osobna zbiórka oraz recykling zużytego sprzętu pomogą w ochronie zasobów
naturalnych i zapewnią ponowne wprowadzenie go do obiegu w sposób chroniący zdrowie człowieka
i środowisko. Aby uzyskać więcej informacji o tym, gdzie można przekazać zużyty sprzęt do
recyklingu, należy się skontaktować z urzędem miasta, zakładem gospodarki odpadami lub sklepem,
w którym zakupiono produkt.
C-14
Safety and EMC Regulatory Statements
Waste Electrical and Electronic Equipment (WEEE) Statements
Descarte de Lixo Elétrico na Comunidade Européia
Este símbolo encontrado no produto ou na embalagem indica que o produto não deve ser descartado
no lixo doméstico comum. É responsabilidade do cliente descartar o material usado (lixo elétrico),
encaminhando-o para um ponto de coleta para reciclagem. A coleta e a reciclagem seletivas desse
tipo de lixo ajudarão a conservar as reservas naturais; sendo assim, a reciclagem será feita de uma
forma segura, protegendo o ambiente e a saúde das pessoas. Para obter mais informações sobre locais
que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço
de coleta de lixo ou com a loja em que o produto foi adquirido.
Likvidácia vyradených zariadení v domácnostiach v Európskej únii
Symbol na výrobku alebo jeho balení označuje, že daný výrobok sa nesmie likvidovať s domovým
odpadom. Povinnosťou spotrebiteľa je odovzdať vyradené zariadenie v zbernom mieste, ktoré je
určené na recykláciu vyradených elektrických a elektronických zariadení. Separovaný zber a
recyklácia vyradených zariadení prispieva k ochrane prírodných zdrojov a zabezpečuje, že recyklácia
sa vykonáva spôsobom chrániacim ľudské zdravie a životné prostredie. Informácie o zberných
miestach na recykláciu vyradených zariadení vám poskytne miestne zastupiteľstvo, spoločnosť
zabezpečujúca odvoz domového odpadu alebo obchod, v ktorom ste si výrobok zakúpili.
Odstranjevanje odslužene opreme uporabnikov v zasebnih gospodinjstvih v Evropski uniji
Ta znak na izdelku ali njegovi embalaži pomeni, da izdelka ne smete odvreči med gospodinjske
odpadke. Nasprotno, odsluženo opremo morate predati na zbirališče, pooblaščeno za recikliranje
odslužene električne in elektronske opreme. Ločeno zbiranje in recikliranje odslužene opreme
prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju neškodljiv
način. Za podrobnejše informacije o tem, kam lahko odpeljete odsluženo opremo na recikliranje, se
obrnite na pristojni organ, komunalno službo ali trgovino, kjer ste izdelek kupili.
Bortskaffande av avfallsprodukter från användare i privathushåll inom Europeiska Unionen
Om den här symbolen visas på produkten eller förpackningen betyder det att produkten inte får
slängas på samma ställe som hushållssopor. I stället är det ditt ansvar att bortskaffa avfallet genom att
överlämna det till ett uppsamlingsställe avsett för återvinning av avfall från elektriska och elektroniska
produkter. Separat insamling och återvinning av avfallet hjälper till att spara på våra naturresurser och
gör att avfallet återvinns på ett sätt som skyddar människors hälsa och miljön. Kontakta ditt lokala
kommunkontor, din närmsta återvinningsstation för hushållsavfall eller affären där du köpte produkten
för att få mer information om var du kan lämna ditt avfall för återvinning.
C-15
Safety and EMC Regulatory
Statements
Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la
Unión Europea
Este símbolo en el producto o en su envase indica que no debe eliminarse junto con los desperdicios
generales de la casa. Es responsabilidad del usuario eliminar los residuos de este tipo depositándolos
en un "punto limpio" para el reciclado de residuos eléctricos y electrónicos. La recogida y el reciclado
selectivos de los residuos de aparatos eléctricos en el momento de su eliminación contribuirá a
conservar los recursos naturales y a garantizar el reciclado de estos residuos de forma que se proteja
el medio ambiente y la salud. Para obtener más información sobre los puntos de recogida de residuos
eléctricos y electrónicos para reciclado, póngase en contacto con su ayuntamiento, con el servicio de
eliminación de residuos domésticos o con el establecimiento en el que adquirió el producto.
— This page is intentionally unused. —
Index
Numerics
10/100Base-TX ports
location on switch … 1-3
1000Base-LH
connections, length limitations … 2-6
ports, cables used with … 2-6
1000Base-LX
connections, length limitations … 2-6
ports, cables used with … 2-6
1000Base-SX
connections, length limitations … 2-6
ports, cables used with … 2-6
1000Base-T
connections, length limitations … 2-5
ports, cables used with … 2-5
600 RPS/EPS
cables … 2-22
connectivity … 2-24
LEDs … 2-23
operating characteristics … 2-22
610 EPS
cables … 2-27
connectivity … 2-28
LEDs … 2-27
operating characteristics … 2-27
A
AC power connector
location on back of switch … 1-10
acoustic specifications … A-2
auto MDI/MDI-X operation … B-7, B-9
HP Auto-MDIX feature … B-5
B
C
cabinet
mounting the switch in … 2-11
cable
EPS cable length … 2-22
RPS cable length … 2-22
cable length specifications … A-3
cables
1000Base-LH
connections … 2-6
fiber-optic cable specifications … B-2
1000Base-LX
connections … 2-6
fiber-optic cable specifications … B-2
1000Base-SX
connections … 2-6
fiber-optic cable specifications … B-2
1000Base-T connections … 2-5
connecting cables to switch ports … 2-20
effects of non-standard cables … 4-2
fiber-optic, specifications … B-2
infrastructure requirements … 2-5
length limitations … 2-5
required types … 2-5
serial, for direct console connection … 2-31
Index – 1
Index
back of switch
description … 1-10
power connector … 1-11
backbone switch
topology with … 2-35, 2-38–2-39
basic switch configuration
IP address … 3-3
manager password … 3-2
subnet mask … 3-3
Switch Setup screen … 3-2
basic troubleshooting tips … 4-1
blinking LEDs
error indications … 4-4
Bootp
automatic switch configuration … 3-2
for in-band access … 2-30
BTU ratings … A-2
buttons
Clear button … 1-9
Reset button … 1-9
Index
cables, twisted pair
category 3, 4, 5 … B-5
cross-over cable pin-out … B-8
MDI-X to MDI connections … B-7, B-9
MDI-X to MDI-X connections … B-8
pin-outs … B-7, B-9
straight-through cable pin-out … B-7, B-9
switch-to-computer connection … B-7, B-9
switch-to-switch or hub connection … B-8
cables, twisted-pair
HP Auto-MDIX feature … B-5
wiring rules … B-5
cables, twisted-pair connector pin-outs … B-5
cabling infrastructure … 2-5
Clear button
deleting passwords … 1-9
description … 1-9
location on switch … 1-3, 1-9
restoring factory default configuration … 1-9,
4-11
to delete password protection … 3-4
CLI prompt, console
displaying … 2-31
configuration
checking when troubleshooting … 4-3
DHCP/Bootp … 3-2
full duplex only for mini-GBICs … 2-7
IP address … 3-3
IP address, manually … 3-2
manager password … 3-2
restoring factory defaults … 1-9, 4-11
subnet mask … 3-3
Switch Setup screen … 3-2
connecting the switch to a power source … 2-19
connecting the switch to an EPS … 2-27–2-28
connecting the switch to an RPS/EPS … 2-24–2-26
connector specifications … A-3
console
checking messages during
troubleshooting … 4-9
displaying the CLI prompt … 2-31
features … 2-30
how to connect in-band … 2-30
how to connect out-of-band … 2-30
serial cable connection … 2-31
Switch Setup screen … 3-2
Telnet access … 3-5
terminal configuration … 2-30
2 – Index
console port
definition … 1-11
location on switch … 1-3
cross-over cable
pin-out … B-8
D
deleting passwords … 1-9
description
back of switch … 1-10
front of switch … 1-3
LEDs … 1-4
switch … 1-1
desktop switch
sample topology … 2-32, 2-36
DHCP
automatic switch configuration … 3-2
for in-band access … 2-30
diagnostic tests … 4-9
checking the console messages … 4-9
checking the LEDs … 4-9
end-to-end connectivity … 4-10
testing the switch only … 4-9
testing twisted-pair cabling … 4-10
downloading new switch software … 4-12
dual-personality ports
LEDs … 1-6
location on switch … 1-4
operation description … 1-4
E
electrical specifications, switch … A-1
EMC regulatory statements … C-8
environmental specifications
BTU ratings … A-2
environmental specifications, switch … A-2
EPS
connecting to a switch … 2-27–2-28
F
factory default configuration, restoring … 1-9, 4-11
Fan Status LED … 1-5
Fault LED … 1-4
behavior during self test … 2-11
behaviors … 1-4
blinking definition … 1-5–1-6, 1-8
location on switch … 1-3
showing error conditions … 4-4
features
console … 2-30
switch … 1-11
fiber-optic cables … B-2
1000Base-LH … B-2
1000Base-LX … B-2
1000Base-SX … B-2
front of switch … 1-3
10/100Base-TX ports … 1-3
Clear button … 1-9
description … 1-3
dual-personality ports … 1-4
LEDs … 1-4
network ports … 1-4
Reset button … 1-9
full-duplex fixed configuration
effects on network connections … 4-1
full-duplex operation of mini-GBICs … 2-7
G
Gigabit-LH
ports, cables used with … B-2
Gigabit-SX
ports, cables used with … B-2
Gigbit-LX
ports, cables used with … B-2
H
horizontal surface
mounting switch on … 2-19
HP Auto-MDIX
feature description … B-5
in-band … 3-1
in-band console access
types of … 2-30
included parts … 2-1
L
laser specifications … A-3
LEDs
behavior during self test … 2-10
blinking definition … 1-5–1-6, 1-8
checking during troubleshooting … 4-9
descriptions of … 1-4
dual-personality ports … 1-6
error indications … 4-4
Fan Status … 1-5
Fault … 1-4
behavior during self test … 2-11
showing error conditions … 4-4
location on switch … 1-3
on switch … 1-4
port
description … 1-6
Power … 1-4
behavior during self test … 2-11
Self Test … 1-5
behavior during self test … 2-10
T and M … 1-6
length limitations
1000Base-LH connections … 2-6
1000Base-LX connections … 2-6
1000Base-SX connections … 2-6
1000Base-T connections … 2-5
link test … 4-10
location for the switch, considerations … 2-6
M
MDI-X to MDI network cable … B-7, B-9
MDI-X to MDI-X network cable … B-8
Index – 3
Index
I
installation
connecting the switch to a power source … 2-19
horizontal surface mounting … 2-19
location considerations … 2-6
network cable requirements … 2-5
precautions … 2-4
rack or cabinet mounting … 2-11
site preparation … 2-5
wall mounting … 2-16
IP address
configuring … 3-3
IP telephones … 2-36
mini-GBICs
full-duplex operation … 2-7
slot, location on switch … 1-3
mounting the switch
in a rack or cabinet … 2-11
precautions … 2-4
on a horizontal surface … 2-19
on a wall … 2-16
precautions … 2-16
Multiple-Display Port LEDs … 1-7
N
network cables
1000Base-LH connections … 2-6
1000Base-LX connections … 2-6
1000Base-SX connections … 2-6
1000Base-T connections … 2-5
fiber-optic, specifications … B-2
HP Auto-MDIX feature … B-5
required types … 2-5
twisted-pair connector pin-outs … B-5
twisted-pair, wiring rules … B-5
network devices
connecting to the switch … 2-20
network ports
connecting to … 2-20
location on switch … 1-4
standards compliance … A-3
types of … 1-4, 2-5
non-standard network cables, effects … 4-2
O
out-of-band console access … 3-5
Index
P
parts, included with the switch … 2-1
password
configuring … 3-2
passwords
deleting with the Clear button … 3-4
if you lose the password … 3-4
passwords, deleting … 1-9
physical specifications, switch … A-1
Ping test … 4-10
4 – Index
pin-outs
twisted-pair cables … B-5
port configuration
checking when troubleshooting … 4-3
port LEDs
description … 1-6
normal operation … 2-11
T and M … 1-6
ports
10/100Base-TX, location on switch … 1-3
connecting to … 2-20
console … 2-30
HP Auto-MDIX feature … B-5
network connections … 2-20
power connector … 1-11
Power LED … 1-4
behavior during self test … 2-11
behaviors … 1-4
location on switch … 1-3
power source
connecting the switch to … 2-19
Power-over-Ethernet
PoE … 2-21
PoE power … 1-2
precautions
mounting the switch … 2-4
power requirements … 2-4
preparing the installation site … 2-5
Proactive Network tools
diagnostics with … 4-8
ProCurve 600 Redundant and External Power Supply … 1-2
ProCurve 610 External Power Supply … 1-2
R
rack
mounting precautions … 2-4
mounting the switch in … 2-11
Redundant and External Power Supply … 1-2
RPS/EPS … 2-21
Redundant Power Supply … 2-21
regulatory statements … C-8
Reset button
description … 1-9
location on switch … 1-3, 1-9
restoring factory default configuration … 4-11
resetting the switch
factory default reset … 4-11
location of Reset button … 1-9
troubleshooting procedure … 4-9
RPS/EPS … 2-21
cables … 2-22
connecting to a switch … 2-24–2-26
operation … 2-22
S
T
Telnet access to the console … 3-5
terminal configuration … 2-30
testing
checking the console messages … 4-9
checking the LEDs … 4-9
diagnostic tests … 4-9
end-to-end communications … 4-10
link test … 4-10
Ping test … 4-10
switch operation … 4-9
switch-to-device communications … 4-10
twisted-pair cabling … 4-10
tips for troubleshooting … 4-1
topologies
effects of improper topology … 4-2
samples of … 2-32, 2-36
Index – 5
Index
safety and regulatory statements … C-1
safety specifications … A-3
segment switch
sample topology … 2-33, 2-37
self test
Fault LED behavior … 2-11
LED behavior during … 2-10
Power LED behavior … 2-11
Self Test LED … 1-5
behavior during factory default reset … 4-11
behavior during self test … 2-10
serial cable
for direct console connection … 2-31
SFP ports … 1-2
slots for mini-GBICs
location on switch … 1-3
Spd LED
blinking definition … 1-8
specifications
acoustic … A-2
cable length … A-3
connectors … A-3
electrical … A-1
environmental … A-2
laser … A-3
physical … A-1
safety … A-3
straight-through cable
pin-out … B-7, B-9
subnet mask
configuring … 3-3
summary
of cables used with the switch … 2-5
switch
connecting to a power source … 2-19
description … 1-1
downloading new software … 4-12
electrical specifications … A-1
environmental specifications … A-2
features … 1-11
front panel description … 1-3
included parts … 2-1
LED descriptions … 1-4
mounting in a rack or cabinet … 2-11
mounting on a wall … 2-16
mounting on horizontal surface … 2-19
physical specifications … A-1
switch operation
verifying after installation … 2-9
Switch Setup screen … 3-2
configuring a subnet mask … 3-3
configuring an IP address … 3-3
field descriptions … 3-3
switch specifications … A-1
switches
2626-PWR, 2650-PWR, 2600-8, Switch 2600-PWR Series … 1-2
troubleshooting … 4-1
basic tips … 4-1
checking port configuration … 4-3
checking the console messages … 4-9
checking the LEDs … 4-9
common network problems … 4-1
connecting to fixed full-duplex devices … 4-1
diagnostic tests … 4-9
effects of improper topology … 4-2
effects of non-standard cables … 4-2
link test … 4-10
Ping test … 4-10
Proactive Network tools … 4-8
restoring factory default configuration … 4-11
testing connections to other devices … 4-10
testing end-to-end communications … 4-10
testing the switch … 4-9
testing the twisted-pair cables … 4-10
twisted-pair cable
cross-over cable pin-out … B-8
pin-outs … B-5, B-7, B-9
straight-through cable pin-out … B-7, B-9
switch-to-computer connection … B-7, B-9
switch-to-switch or hub connection … B-8
testing … 4-10
twisted-pair ports
HP Auto-MDIX feature … B-5
V
VT-100 terminal
serial cable connection for … 2-31
W
wall
Index
mounting switch on … 2-16
wireless access point
WAP … 2-36
wiring rules for twisted-pair cables … B-5
6 – Index
Technical information in this document
is subject to change without notice.
© Copyright 2001, 2005
Hewlett-Packard Development Company, L.P.
Reproduction, adaptation, or translation
without prior written permission is prohibited
except as allowed under the copyright laws.
Printed in Taiwan
September 2005
Manual Part Number
5991-2165, Rev. B
*5991-2165*

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project