DIU 210 - CEM Systems

DIU 210 - CEM Systems
DIU 210
Door Interface Unit
Features that make a difference:
•
Door Interface Electronics held on one
board
•
Provides a coded lock serial interface
between door hardware and card reader
•
On site selectable for 12V or 24V lock
output
•
Fire alarm and break glass inputs for
emergency door release
•
Designed for ease of installation and
maintenance using 2 part connectors
throughout
•
Compliant with EN55022 (emissions) and
EN55024 (access control immunity)
•
Backup battery connection for emergency
power
The Door Interface Unit (DIU 210)
is designed primarily to provide
power to a door lock, as well as
local power to a CEM reader when a
high level of security is required.
Upon a valid swipe at the card reader, the
reader will instruct the DIU (over the RS485
communications channel) to activate the
appropriate output to release the lock using
a coded data signal (i.e. coded lock).
It has onboard inputs which can be used
to monitor conditions such as a fire alarm
or activated Break-glass condition.
The DIU 210 improves door security,
by allowing the installer to locate
lock controls on the secure side of a
door, with an intelligent CEM reader
on the unsecured side. The DIU 210
communicates with an intelligent CEM
reader over a single pair RS485 cable.
As an added benefit, the DIU 210 monitors
the status of all standard door monitoring
inputs; inputs on an intelligent CEM reader
are free for use as general purpose inputs.
The DIU 210 is supplied in a steel enclosure
complete with power supply backplane and
an output for an additional door holder.
www.cemsys.com
1.
2.
3.
4.
5.
6.
7.
8.
9.
DIU Unit Enclosure
CEM Reader
Sounder
Break Glass Unit
REX/Exit Reader or Secure side push button
Door Holder
Door Lock
Lock Sense
Door Position sensor
Interfaces
Specifications
The DIU 210 provides direct interfaces to the following devices:
Size . . . . . . . . . . . . . . . . . . . . 300 x 250 x 150 mm (11.8 x 9.84 x 5.9in)
Weight . . . . . . . . . . . . . . . . . . 4.3Kg
• CEM Card Reader
• Electric Door Lock
• Fire Alarm System
• Break Glass Unit
• Exit Push Button
• Power Fail
• Battery Low
• Enclosure Tamper
Power
Voltage . . . . . . . . . . . . . . . . . 100-240VAC, 50/60Hz
Current Consumption . . . . . Minimum: 57mA (excluding locks and heads
Maximum: 175mA (including locks and heads)
8 inputs can be used for alarm/status monitoring devices
directly to the DIU 210. These devices are used to
monitor door sensors, DIU tamper and battery alarms
and fire/ break glass emergency conditions.
If an input from the fire alarm system or break glass unit
changes state, the power to the door lock is automatically
dropped; this hardware-controlled facility ensures that the
door opens in an emergency situation. Details of alarm
conditions can be sent directly to the door controller or to
the host, via the card reader, for central alarm notification
Board Protection
The DIU 210 has been designed to meet the UL294
standard providing resistance to power supply tamper,
limiting the current to a reader so that shorting together
the 12 Volt terminals prevents the lock from opening.
Reader inputs
The DIU 210 can also monitor the status of all the door furniture
inputs, freeing up to another eight inputs on the intelligent
CEM readers for general purpose input monitoring.
PSU Backplane Board and Enclosure
The DIU 210 is supplied with a steel enclosure and
backplane board providing a mains input PSU, battery
charging capabilities and door holder connections
Environmental
Temperature . . . . . . . . . . . . . -10º to 40ºC (14º to 104ºF)
Humidity . . . . . . . . . . . . . . . 95% non condensing LED Indicators . . . . . . . . . . . . +12 Volts OK, Lock supply OK, Lock Status, Watchdog, Fault, Battery Low, RS485 Rx and TX
Functionality
Inputs . . . . . . . . . . . . . . . . . . . Door Position*
Lock Status*
Exit Push Button*
Break Glass Sense
Fire Alarm Sense
Power Fail
Tamper
Battery Low (reported internally)
Dedicated Power Fail Input
* = 4 state tamper protected inputs
Outputs . . . . . . . . . . . . . . . . . Two12V or 24V open collector outputs limited to 1.5A for Door Lock and Door Holder and one 12v External Sounder output
Reader Output . . . . . . . . . . . 12V, limited to 800mA
Memory . . . . . . . . . . . . . . . . . 32kB Flash memory
Communication Interface
To Card Reader . . . . . . . . . . . RS485 multidrop cable runs using copper wire with maximum length of 1.2km without repeater
Connection . . . . . . . . . . . . . . . 2 part screw terminals
Requirements
Compatible with the AC2000 access control family:
• AC2000 SE
• AC2000 AE
• AC2000 Lite
Ordering Information
Product Code
Description
DIU/700/210
DIU 210 (Complete with PSU
Backplane and Enclosure)
Related Products
AC2000 SE
AC2000 AE
AC2000 Lite
www.cemsys.com
© 2013 Tyco Security Products. All Rights Reserved. CEM/B/045 Rev E
The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco will aggressively enforce its intellectual
property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by Tyco are the property of their respective owners, and are used with permission or allowed
under applicable laws.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative.