NEW 16kW T-CAP - Panasonic PRO Club

NEW 16kW T-CAP - Panasonic PRO Club
PRODUCT READY FOR THE NEW ErP
ECODESIGN REQUIREMENTS LOT 1
A
class pump
Adding many
new functions
Auto mode, Holiday mode,
power consumption
display, …
NEW 16kW T-CAP
T-CAP stands for Total Capacity.
This line-up is able to maintain the
same nominal capacity even at
-15°C without the help of an
electrical booster heater.
High heating
capacity even at
low ambient
Keep capacity of 16kW
until -15°C outdoor
temperature
Install A Class pump
Industry top class
energy-saving!
NEW 16KW T-CAP. HIGH CAPACITY IMPROVEMENT
AT LOW AMBIENT & HIGH EFFICIENCY
Enhance larger capacity (16kW)
More Energy saving with A Class pump.
Adding new functions
Auto mode, Holiday mode, Displays power consumption, New
de-ice control, Concrete Dry mode, Lock cooling mode and
Pump speed control.
Applications
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic UK Ltd.
AQUAREA AIR RADIATORS. PAW-AAIR-900 / PAW-AAIR-700 / PAW-AAIR-200
Panasonic has developed a new radiator line up working with
water at 35°C in order to:
· Make the installation easier, with 2 zones kits and additional
pumps
· Increase the efficiency by 32% over standard radiators
working at 45°C
· Makes cooling operation possible to increase comfort
32%
FICIENT
MORE EF DARD
N
THAN STA RS
Heating, cooling and dehumidification functions (drain RADIATO
pipe for cooling and dehumidification is needed)
www.eggeassociats.net
SEASONAL
EFFICIENCY
Industry top
class COP
High efficiency
product
ACCESSORIES
Radiators
A selection tool is available on www.panasonicproclub.com
Operating on heating
mode with radiator using
only radiant effect
Tanks
STANDARD SANITARY
HIGH EFFICIENCY
Operating on heating
mode with radiant
effect and fan mode
Operating on
cooling mode
with fan
SUPER HIGH EFFICIENCY
Panasonic has a large line up of tanks with high efficiency and
high insulation allowing in certain cases for the tank to be
installed in a non heated part of the house (such as garage,
cellar, etc…) without affecting the efficiency of the house.
WH-TD20E3E5
WH-TD30E3E5-1
HR 200
HR 300
HRS 200
HRS 300
Heat up time
Valuation
★★★★
★★★★
★★★★
★★★★
★★★★
★★★★
★★★★
Energy losses
Valuation
★★★★
★★★★
★★★★
★★★★
★★★★
★★★★
★★★★
Efficiency of the tank
Valuation
Warranty
HRS 500
★★★★
★★★★
★★★★
★★★★
★★★★
★★★★
★★★★
10 years
10 years
7 years
7 years
7 years
7 years
7 years
NEW T-CAP 16kW.
CONSTANT CAPACITY OF 16kW
AT OUTDOOR TEMPERATURES
DOWN TO -15°C
Control & connectivity
Aquarea Manager
Ready Steady Go. Easy Installation & Easy Configuration.
Ready: Pre-programmed with up to 600 applications/
system diagrams. Steady: At start up - state the number
of application/system diagram. Go: The controller starts
working according to selected diagram
PAW-HPM1: for 2 zones cascade and bivalent applications.
For more information: www.panasonicproclub.com
Room Thermostats
PAW-A2W-RTWIRED: Wired LCD room thermostat with
weekly timer.
PAW-A2W-RTWIRELESS: Wireless LCD room thermostat
with weekly timer.
Internet control
Internet Control is a next generation system providing
user-friendly remote control of heat pump units from
anywhere, using a simple Android or iOS smartphone,
tablet or PC via internet.
A simple Installation: Just connect the Internet Control
device to the heat pump with the supplied wire and then
link it to your WIFI Access point.
Connectivity to Modbus / KNX / EnOcean
Panasonic allows for optimum integration with BMS
systems. Panasonic have designed a range of interfaces
for Panasonic specifically to provide complete
monitoring, control and full functionality of the entire
Aquarea line-up from KNX, EnOcean and Modbus
installations.
Photovoltaic Solar panels
+
Heat Pump + HIT Photovoltaic solar panel from Panasonic
Photovoltaic solar panels: the best solution for big savings.
Combining photovoltaic solar panels with your heat pump can
help to further reduce your electrical consumption and CO2
emissions. Additionally, with the unique HIT photovoltaic solar
panel technology from Panasonic, you can produce more
electricity per square metre, helping you to increase your
energy savings still further.
RY
· INDUST S
S
TOP CLA Y
C
EFFICIEN
To find out how Panasonic cares for you,
log on to: www.aircon.panasonic.eu
Contact Details:
Telephone: 01344 853182
www.panasonic.co.uk/aircon
For retrofit houses
Replace easily expensive gas or oil boilers for high
efficient 16kW T-CAP or manage bivalent installations
(heat pump and existing gas or oil boiler) with the Heat
Pump Manager.
Further information on: www.panasonicproclub.com
For commercial applications
Wide range of capacities now covered - from 9kW to
45kW with the Heat Pump Manager. Also you are able
to connect up to three heat pumps on cascade with the
Heat Pump Manager.
For heating and cooling mode
The 16kW model is able to heat the water at 55°C and is
highly efficient even when the temperature is as low as
-20°C. Cooling operation can be activated on the remote
control to cool water up to +5°C.
For heating and sanitary hot water
Efficient domestic hot water tanks allow large storage
for high consumption of hot water (for example Jacuzzi
or bathtub). All our tanks have an anti-legionella
protection with a backup heater of 3 kW.
Address: Panasonic Air Conditioning
Panasonic House
Willoughby Road
Bracknell
Berkshire
RG12 8FP
NEW AQUAREA AIR TO WATER HEAT PUMP 2013 / 2014
New indoor unit design
· New A-class pump with 7 speeds
· Expansion vessel of 10L
· Selectable booster heater (3/6/9kW)
Low power consumption of the pump (only 45 W)
With the new 16kW T-CAP you can save around 55 ¤ per Year¹.
1. Assuming a yearly cost of 220 € for the standard pump, can vary depending on size and consumption.
NEW FEATURES
1
5
Equivalent to
Flow switch
Automatic air purge
55 €/year
saving¹
Water heat plate
exchanger
2
6
Water pump
High efficiency pump
made by Panasonic
135 W
Panasonic T-CAP
A Class Pump
The new 16kW maintains full capacity of 16kW even at outdoor temperatures down to -15°C.
New remote control functions
2
Pressure relief valve
The whole T-CAP line-up can replace old gas or oil boilers, and in a new application with under floor heating, low temperature radiators or even fan-coil
heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to
connect a thermostat for even better heating or cooling control and management.
The 16kW fits perfectly to retrofit houses, as well as to commercial applications to heat and cool the applications and also to provide sanitary hot water.
A CLASS PUMP. MORE ENERGY SAVING
SEASONAL
EFFICIENCY
· Backup heater capacity can be selected (3/6/9kW)
· Cooling mode activation possible by software*
Capacity is stable even
at -15°C, no need to
oversize the heat pump
eede
d to h
eat t
he ho
use
14
-7°C
+2°C
+7°C
Outdoor temperature
10
18kW
8
16kW
Panasonic heat pump does
not need heater as the
capacity is maintained
6
Capa
city n
0
+7°C
+2°C
-7°C
mp
at pu
r he
Othe
Other Heat pumps need
electrical heater to cover
the demand of the house
2
Bad performance
to big capacity
16kW T-CAP
Capacity in kW
4
Capacity of other heat pumps need to be
higher than the Panasonic heat pumps
eede
d to h
eat t
· High flexibility with
Panasonic Inverter
compressors
· High performance
even at part load
he ho
Internet
Control
Ready
use
INTERNET CONTROL
-15°C
Solar
Outdoor temperature with heating water at 35°C
T-CAP 16kW
Current 16kW
-15°C
-7°C
+2°C
Outdoor temperature
100%
AL
-15°C
Technical focus
· High efficiency A Class pump
· Maintains 16kW capacity at outdoor temperatures down to
-15°C (at heating water temperature of 35°C/45°C)
· Three Phase model
· Works down to -20°C
· Cooling temperature range: 5°C-20°C
· Heating temperature range 25°C-55°C
N
city n
16
12
3
3. Holiday Mode
Helps you to reduce heating temperature during
holidays.
+7°C
capacity
at -15 ºC
High
Environmentally
efficiency
heating
refrigerant
-20 ºC in
connection
heating mode
R410A
OUTDOOR
TEMPERATURE
RETROFIT
AQUAREA T-CAP
Domestic
Easy
panels
connection
hot water
control
by BMS
SOLAR KIT
DHW
CONNECTIVITY
INTERNET CONTROL READY: Optional.
friendly
5 year
compressor
warranty
Down to
Boiler
T-CAP 16kW
Heating Capacity at +7°C with heating water at 35°C
COP at +7°C with heating water at 35°C
Heating Capacity at +2°C with heating water at 35°C
COP at +2°C with heating water at 35°C
Heating Capacity at -7°C with heating water at 35°C
COP at -7°C with heating water at 35°C
Heating Capacity at -15°C with heating water at 35°C
COP at -15°C with heating water at 35°C
Cooling capacity at 35°C with cooling water at 7°C
EER at 35°C with cooling water at 7°C¹
Indoor unit
Dimensions / Weight
HxWxD
Water pipe connector
Pump
No. of Speed
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current / Maximum Current
Outdoor unit
Sound pressure level
Sound power level
Dimensions / Weight
HxWxD
Pipe diameter
Liquid / Gas
Refrigerant (R410A) / Additional gas amount
Pipe length range
Pipe length for nominal capacity / additional gas
I/D&O/D Hight Difference
Operation range
Outdoor ambient
Water outlet
Heating / Cooling
kW
kW
kW
kW
kW
mm / kg
l/min
kW
kW
A
dB(A)
dB
mm / kg
mm (Inch)
kg / g/m
m
m
m
°C
°C
Performance (capacity and COP) determined at 230V only in accordance with EN14511 standard.
Three Phase (Power to indoor)
16.00
4.28
16.00
3.07
16.00
2.49
16.00
2.32
12.20
2.57
WH-SXC16F9E8
892 x 502 x 353 / 47
R1 1/4
7
45.9
9
3.74
7.2 / 15.5
WH-UX16FE8
53
70
1340 x 900 x 320 / 127
9.52 (3/8) / 15.88 (5/8)
2.90
3 – 30
7 / 10
20
-20 to 35
25 – 55 / 5 – 20
· 1 stage for 1 day (max. 99 stages)
· Min 25°C to 55°C
Day
5. Heating and Cooling Mode
Authorized service partner or Authorized installer
can enable the cooling mode through a special
operation via the remote controller on site.
6. Pump with 7 speeds
Pump speed can be selected on the remote
control with 7 steps.
class pump
IO
Capa
4. Floor heating concrete dry mode
Allows to increase temperature of floor heating
slowly via software.
· High flexibility with
Panasonic Inverter
compressors
· High performance
even at part load
OP
T
Capacity in kW
Heating Capacity
18
1. Auto Mode
Automatically changes from heating to cooling
depending on outdoor temperature.
A
16kW
16kW T-CAP
kW
For installer
PRODUCT READY FOR THE NEW ErP
ECODESIGN REQUIREMENTS LOT 1
* This activation can only be done by service partner or installer
16kW
For customer
2. Energy Consumption
Displays the heat pump’s energy consumption,
split by heating, cooling and domestic hot
water, and shows total consumption figure.
NEW 16KW T-CAP. TECHNICAL DATA
Aquarea T-CAP maintains the nominal capacity until -15°C
The T-CAP line-up is able to maintain the same nominal capacity even at
-15°C without the help of an electrical booster heater. T-CAP is also able
to provide extremely high efficiencies, whatever the outside or the water
temperature. Panasonic has now extended the range with the new three
phase 16kW.
4
7. New de-ice control
Panasonic has developed a new de-icing control system which dramatically
reduces the requirement for a back-up heater, increasing the efficiency of
the heat pump.
8. Inspection port to compressor terminal
For easier maintenance you are now able to access through a plate to
check the compressor terminal.
8
125
125
180 W
Standard
3
Heater assembly
3/6/9kW selectable on
the remote control
Temperature
THE NEW T-CAP RANGE HAS EXTENDED
WITH THE ADDITION OF THE 16KW PUMP
Expansion vessel 10l
Was this manual useful for you? yes no