industrial catalog - Cooper
Accuracy to the Highest Degree
INDUSTRIAL CATALOG
HVAC/R • Facilities • OEM
Cooper-Atkins Corporation
A customer-centric technology leader in monitoring solutions for the global
Foodservice, Healthcare and Industrial markets.
Carol P. Wallace has been the
President and CEO of CooperAtkins Corporation since 1994 and is
recognized by the WBENC for leading
a successful and thriving womanowned corporation. The WBENC
is the largest third-party certifier of
businesses owned, controlled, and
operated by women in the U.S.
Contents
The Industrial Market - a Changing Landscape.........................3
NotifEye™ Cloud-based Wireless Monitoring........................... 4
NotifEye™ Grower’s Kit............................................................. 5
EnviroTrak™ Wireless Monitoring............................................. 6
Blue2™ Bluetooth Temperature Transmission.......................... 7
HACCP Manager™ Solo........................................................... 8
HACCP Manager™ Enterprise.................................................. 9
HACCP Manager™ Mobile........................................................ 9
TM
TravAlert
Company History
The inventor of the first bi-metal oven thermometer, David G.
Cooper, founded The Cooper Oven Thermometer Company in
1885. During the 1960s, the company developed three cooking
product lines and with the acquisition of The Croydon Thermometer
Company expanded into weather instrumentation. Two separate
marketing groups were established for the consumer and industrial
markets to advance these new product lines.
In 1984, the industrial division of Electromedics (Electro-Therm)
was purchased, immediately launching Cooper into the digital
thermometer business. The company officially became
Cooper Instrument Corporation strengthening its presence in the
HVAC/R, OEM and industrial markets.
In 2001, after acquiring Atkins Technical (a leader in thermocouple
instrument technology), the company became known as
Cooper-Atkins Corporation.
In 2003 the corporation acquired KTG, Inc., a developer of
wireless enterprise solutions for temperature monitoring and food
safety.
Company Overview
Since its establishment in 1885, Cooper-Atkins has built a 130-year,
rock-solid reputation providing quality environmental monitoring
solutions to top brands such as Mars Chocolate, Subway, Pepsico,
Quaker Oats, Nestle, and many, many more. Our proven track
record speaks for itself.
In today’s rapidly changing world, we continue to expand our
technological capabilities to support and protect brand integrity by
providing the right tools that ensure consistent food quality and
safety across all our business units.
2
Data Loggers........................................................ 10
Thermistor Instruments.......................................................11-12
Thermistor Probes....................................................................13
Dual Input Thermocouple Kits................................................. 14
EconoTemp™ Thermocouple Instruments.............................. 15
AquaTuff™ Thermocouple Instruments............................. 16-17
Type K Thermocouple Probes.............................................18-19
Digital Panel Thermometers................................................20-21
Vapor Tension Panel Thermometers....................................... 22
Bi-metal Thermometers........................................................... 23
Digital Pocket Test Thermometers.................................... 24-25
Val CupTM and Probe Wipes.................................................... 25
Infrared Thermometers...................................................... 26-27
Refrigerator/Freezer Thermometers.........................................28
Hot-holding Thermometers.......................................................28
Digital/Wall Thermometers..................................................29-30
Timers...................................................................................... 31
McDonald’s awarded
Cooper-Atkins the
“Global Supplier
of the Year 2015”
The Industrial Market - a Changing Landscape
Emerging wireless and digital technology is at the forefront of indoor and environmental temperature monitoring. As an industry leader,
we continue to provide state-of-the-art technology to help meet our customers’ needs.
Facilities are becoming “smart” and automated and we recognize the need to: integrate into current Building Automation & Control
Networks (BACnet); offer real-time monitoring of labs and indoor air-quality; and provide wireless monitoring and alerting capabilities to
satisfy government regulatory compliance for food processing facilities! Below are just some of the niche markets that we serve that are
expanding under the industrial business umbrella.
Food Processing
Laboratory
HVAC/R
Agriculture
During processing, temperature
monitoring and control of
pathogens are both critical
to ensuring a food-safe
environment. Automating both
temperatures and humidity
monitoring will increase efficiency
and allow detailed reporting and
compliance with current HARPC/
HACCP plans.
Monitor the temperature and
humidity level in your clean room
with speed and accuracy.
Scientists and technicians rely
on Cooper-Atkins products that
are traceable to the standards of
NIST and are durable, waterproof
and meet recognized industry
certifications.
Technicians and contractors
trust our products in critical IAQ
applications when measuring
temperatures on pipe surfaces;
air flow in rooms and duct work;
or analyzing system pressures in
heating/ air-conditioning.
The reliability and scalability
of products increases field
efficiency.
With the organic and medicinal
industries on the upsurge,
there is a need to control the
temperature & humidity of
greenhouses and holding silos.
Our line of specialty products
are designed for the agriculture
and horticulture markets.
Versatile and scalable, they also
conform to current government
compliances and regulations.
Facilities Maintenance
Refrigeration
Quality tools for the Maintenance
Engineer range from simple
Bi-metal thermometers to wireless
temperature monitoring enterprise
systems. We are committed to
providing the right measurement/
testing instrument, tool or test
equipment for the job.
Quality tools for the refrigeration
technician range from simple
Bi-metal and vapor tension
thermometers to state-ofthe-art wireless monitoring
systems. Used for measuring
temperatures on pipe surfaces,
or analyzing system pressures
in refrigeration equipment,
the durability, reliability and
expandability of our products
have been time tested
Warehousing
Maintaining specific temperature
ranges is important in all areas
of a controlled environment.
Monitoring of temperature
and humidity in refrigerators,
walk-ins, freezers, distribution
and shipping areas is an
important part of the cold
chain management. Accurate
temperature profiling over
prolonged periods ensures
accurate storage temperatures
for your products.
Logistics
Monitor product storage
temperatures during transport
to comply with ”Farm-to-Fork”
traceability. Analayze data to
ensure product temperatures are
not compromised.
3
NotifEye™ Cloud-based Wireless Monitoring
N TIF
TM
EYE
P OW E RE D B Y TE M PTR A K
The NotifEye™ cloud-based temperature monitoring and notification system is a low-cost wireless solution.
System data is accessible on-line 24/7, while out-of-range notifications are sent in real-time as e-mail and text
alerts. Sensors pass information wirelessly to the software database which collects and records data 24/7.
Each sensor is battery operated and monitors against preset conditions that are user-defined within the NotifEye
application.
Cloud-based Monitoring
and Notification System
To View the online system and Live Data!
Log Into: monitoring.notifeyewireless.com
User Name: notifeye
Password: notifeye
How It Works
Sensors
Wireless Sensors Send Data via Gateways to the NotifEye™ System
and Send Out Instant Email and Text Alerts
Gateways
Cloud-based Portal
Email/Text Alerts
#15200 Temperature Sensor*
Gateway Kit #15906 Includes:
• (4) Temp Sensors #15200
• (4) Batteries
• (1) Gateway #15505
• (1) Buffer Cable
• (1) Ethernet Cable
• 1-Year Web Hosting*
Temperature Range: -25° to 180°F (-32° to 82°C)
Accuracy: ±1.2°F (±0.7°C)
#15220 Humidity Sensor
Relative Humidity Range: 0-90% RH
Ambient Operating Range: -4° to 140°F (-20° to 60°C)
Accuracy: ±2% (10-90% RH)
#15230 Contact Sensor
Gateway Kit #15907 Includes:
• (2) Temp Sensors #15200
• (2) Batteries
• (1) Gateway #15505
• (1) Buffer Cable
• (1) Ethernet Cable
• 1-Year Web Hosting*
* Renewal fee each additional year thereafter
Magnet operation gap up to 0.75”
#15201-01 Immersion Probe
Temperature Range: -25° to 180°F (-20° to -60°C)
Accuracy: ±1.2°F (±0.7°C)
Probe Diameter: 0.25” (6.4 mm)
#15505 Gateway Specifications
N TIF
TM
Multiple Applications:
EYE
P O W E R E D B Y TE M P TR A K
•
•
•
•
•
•
•
Refrigerator/Freezers
Walk-ins/Reach-ins
Prep Areas
Steam Tables
Open Air Cases
Hot-holding Cabinets
Salad/Deli Bars
Cloud-based Monitoring
and Notification System
• Operating range: 32° to 140°F (5° to 50°C), up to 90% RH
• 200 Monitoring Points = 30 Days of Storage
#15506 Repeater
• Extends sensor range, transmits up to 4 miles (open field
range)
General Specifications
Sensor Range: 2500 ft (typical interior range of 500 ft)
Probe Lead Length: 6 ft. (1.82 m)*
Battery Life: 2.5 - 3 years
1-year warranty
4
*Temperature sensors available with longer probe leads:
15200-10 - 10 ft. (3.05 m) and 15200-30 - 30 ft. (9.14 m)
NotifEye™ Grower’s Kit
N TIF
TM
EYE
P OW E RE D B Y TE MPTR A K
Cloud-based Monitoring
and Notification System
Install this easy-to-use system to wirelessly monitor soil and air temperatures to ensure environmental conditions are
optimal for planting. This kit is ideal for monitoring both temperature and humidity levels in a greenhouse - two key
factors for successful germination and growing quality crops.
Analyze the system data to make adjustments and save energy by heating only until optimal growing can be
sustained. Also, as an exception-based system, alerts can be sent when preset temperature and humidity limits are
exceeded.
With the organic and medicinal industries on the upsurge, there is a need to control the temperature & humidity of greenhouses and holding silos. Our line of specialty products are versatile and scalable and conform to current government
compliances and regulations.
Gateway
#15505
Growers Kit #15910 Includes:
Immersion Probe
#15201-01
(2) Temperature Sensor #15200-10
(1) Humidity Sensor #15220
(1) Immersion Probe #15201-01
(1) Gateway #15505
1-year Hosting (included)*
*Renewal fee each additional year thereafter
Temperature Sensors
#15200-10
Humidity Sensor
#15220
Alert Features:
• On-screen Alerts and Notifications
sent via Email and SMS Text
• Permission-based Access Control and Reporting
• List of Recent Alerts for Individual
• Sensors
How It Works
Sensor Features:
• Unlimited Number of Networks, Sensors, Gateways and Users Supported
• Sensor Mapping Tool
(Visual Placement)
• Data Reports and Sensor
History Storage
• Visual Charts and Exports
Wireless Temperature and Humidity Sensors Send Data via the Gateway to the
NotifEye™ System. Instant Alerts are sent out when preset limits are exceeded.
Soil
Humidity/Temp
N TIF
TM
EYE
PO W E R E D B Y T E M PT R AK
Sensors
Gateways
Database
Email/Text Alerts
5
EnviroTrak™ Wireless Monitoring Solution
Proper receiving, storing, holding, and monitoring of temperatures is vital in
preventing bacterial growth in foods. The accurate reporting and logging of data
is now a standard measure to ensure HACCP compliance. EnviroTrak offers 24/7
Wireless Monitoring To Protect Your Brand monitoring of temperature, humidity, door open/close, etc., eliminating the need for
labor-intensive manual temperature logs.
TM
Hardware
• Scalable to any size building or campus
• Multiple locations
• Waterproof housing accessories
• Automatic battery backup
• Available in 900 MHz and Wi-Fi
• 900 MHz and Wi-Fi hardware can coexist and
integrate with outside wireless communications
• All EnviroTrak probes function with 900 MHz and
802.11 Wi-Fi transmitters
Software
• View anywhere capability online
• Real-time & historical data
• Instant alerts with escalation levels
• Documentation of corrective actions
• Customized views & reports
• Easy to use navigation
• Enhanced security access controls
• Reports for trend analysis
• Compatible with multiple browsers
Service and Support
• Requires minimal infrastructure
• Automated database backups
• 24/7 live emergency support
• Unlimited web-based training
• Software upgrades
• Mapping Services
• Turnkey Solutions
• IQ/OQ Services
EZ Link*
Respond to EnviroTrak alarms via your mobile
device 24/7.
*compatible with current generation
smartphones and tablets
6
LEARN MORE!
Blue2™ Bluetooth Temperature Transmission
The Blue2 instrument transmits temperatures wirelessly to your mobile device via Bluetooth Low Energy.
The instrument can utilize any interchangeable Type-K temperature probe making it versatile for insertion, air or surface
temperature measurement. The instrument works with a smart device and the HACCP Manager Mobile App. The data
can also be integrated into existing third party applications from information provided by API documentation.
92010-K Kit Includes:
t r um e
r rant y
Wa
Year
51337-K Duraneedle Probe
Utilizes unique screw-lock
n
ns
rI
t
pe r - At ki
Can be used with any
Type K probe
v
• F i e Yea
5
oo
Interchangeable Probes
s
C•
• 20100-K Blue 2 Instrument
• 51337-K DuraNeedle
• Direct Connect Probe
Specifications
#20100-K Blue2 Instrument
Temperature Range: -40º to 999ºF (-40º to 537ºC)
Ambient Operating Range: 32º to 122ºF (0º to 50ºC)
Resolution: 0.1º
Accuracy: ±0.5ºF with ambient temperatures between 68º to 86ºF, add
±0.1ºF per degree outside of this ambient range
RF Range: 100 feet (30.5 m), line-of-sight
Bluetooth Low Energy
The Blue2
instrument works
with the HACCP
Manager Mobile
app and 3rd
party apps
for increased
versatility.
Power: Replaceable 3V Lithium cell battery (CR123A) (Included)
Battery Life: 500 hours
ABS plastic housing with antimicrobial additive
IPX7 waterproof rated
Traceable to NIST standards
5-year Warranty
IC
Note: EMC Compliance: The Blue2 instrument may record temperature measurements
beyond the stated accuracy when exposed to radio frequency disturbances between 250Mhz
and 1000Mhz with a field strength in excess of 3.0V/m. This deviation is temporary and the
Blue2 will recover when the disturbance is removed.
#50337-K DuraNeedle Probe
Temperature Range: -100º to 500ºF (-73º to 260ºC)
Accuracy: ±1ºF
Response Time: 1 second in liquid
Watch the
Video!
Probe Length: 4” (102 mm)
1-year Warranty
7
n
HACCP Manager™ Solo
The planning and training involved in a paper-based HACCP food safety program is laborious, costly and can be a
burden to your business. The Handheld is a portable data-collecting instrument designed to simplify the gathering
of temperatures, manage standard checklist processes and document corrective actions.
Incorporating the HACCP Manager into a safety program will help to eliminate the laborious planning and training
involved in a traditional HARPC/HACCP food safety programs. In addition to time and money savings, it will increase
consumer confidence and ultimately improve the overall customer experience.
t r um e
r rant y
Wa
Year
n
ns
rI
t
pe r - At ki
v
• F i e Yea
5
oo
s
C•
ENTERPRISE
n
93710
HACCP Manager™ Solo Kit
• 37100 Handheld
• 50209-K MicroNeedle Probe
• 9382 Battery Charger
• 9383 USB Cable
• 9384 Software USB
37100 Specifications
Temperature Range: -99.9º to 999.9ºF (-73.2º to 537.7ºC)
Accuracy: ±1°F (±0.5°C)
Resolution: 0.1°
Stores up to 3,000 temperatures and 300 menu items
Stores 1500 checklist records (150 questions)
Water resistant
ABS Plastic with protective rubber boot
Accepts all Type K thermocouple probes
WATCH
THE
VIDEO!
Traceable to NIST standards
Rechargeable lithium ion battery
5-year warranty
Works as a standalone system with software residing on a local
PC. Not Mac Compatible.
8
HACCP Manager™ Enterprise
This state-of-the-art system allows a HARPC/HACCP plan, that complies with
local health codes, to be custom built for any food business. Addressing health
safety concerns is vital in today’s foodservice industry and is, in some cases,
government mandated.
The HACCP Manager Enterprise application is used to build menus and
checklists, which are then downloaded to any of the data collection devices
(handheld or Mobile App).
ENTERPRISE
Critical data is sent to our hosted server via a USB or Wi-Fi connection.
93755
HACCP Manager™ Enterprise Kit
• 37500 WiFi-enabled Handheld
• 50209-K MicroNeedle Probe
• 9382 Battery Charger
• 9383 USB Cable
93751
HACCP Manager™ Enterprise Kit
• 37200 Handheld
• 50209-K MicroNeedle Probe
• 9382 Battery Charger
• 9383 USB Cable
Hosting
HACCP Manager Enterprise is a hosted software solution. It reduces entry
related start-up costs and reduces the reliance on IT for maintenance and
installation.
Specifications
Type K Probes
Interchangeable Type K probes, enable the HACCP Manager to be
used to check temperatures of various food types and equipment
throughout your facility.
Temperature Range: -99.9º to 999.9ºF (-73.2º to 537.7ºC)
Kits & Accessories
The two main kits differ in the Handhelds and how they transfer information.
This 37200 Handheld connects to a Network-based computer bridge via USB
cable. This allows communication with the software database. The 37500
Handheld has a built-in WiFi module to allow wireless data transfer. This model
communicates primarily via Wi-Fi. It operates via the USB cable, in the event a
Wi-Fi connection cannot be established, or for firmware updates.
Water resistant
Accuracy: ±1°F (±0.5°C)
Stores up to 3,000 temperatures and 300 menu items
Stores 1,500 checklist records (150 questions)
ABS Plastic with protective rubber boot
Accepts all Type K thermocouple probes
Traceable to NIST standards
Rechargeable lithium ion battery
5-year warranty
HACCP Manager™ Mobile
To reduce managing reams of paper logs that are laborious to analyze, the
HACCP Manager Mobile App, used with the Blue2 instrument, collects and
stores that information via your smart device. This data can then be uploaded
to the cloud software on the fly, significantly saving time and streamlining the
process of specific HACCP requirements.
The HACCP Manager Mobile App is downloaded to your smart device and
works in conjunction with the Blue2 instrument.
MOBILE
The Blue2 is available as part of a kit that includes a Type K DuraNeedle
Direct Connect probe. The Blue2 instrument transmits temperatures
wirelessly to your mobile device via Bluetooth Low Energy. The App provides
the capability to be used in multiple languages to increase versatility.
• Switch menus and checklists
on the fly
• Multiple language support
• Works with the Blue2 device
• Can be used in conjunction with
Enterprise handhelds
9
TravAlert™ In-transit Data Logging
™
TravAlert™ is most commonly used for monitoring storage temperatures during transportation and
provides highly accurate data for use in the foodservice and industrial markets. It can also be used to
monitor and record temperatures of stationary refrigeration units or hot-holding cabinets.
The self-powered Data Logger is a time and temperature, PC interfacing device that can record up to
2,048 temperatures (in intervals from 1 minute to 4 hours) and is splash, dirt and impact resistant.
2300
TravAlert™ Data Logger Kit
• 9387 Data Logger (5)
• 9364 i-Button Reader Cable (2)
• 9365 USB Adapter (2)
• 9386 Software CD (2)
GL100
Water-resistant, Mini Data Loggers
Data logger tag monitors both time and temperature
• Two (2) mini data loggers
• Two (2) mounts
• Reader and software
•1-year warranty
Not Mac Compatible.
Specifications
Features
Unique user-defined session identity
Go/No-Go Icon for immediate visual
(based on user-defined parameters)
All readings for session shown in graph
and tabular format
Printable to PDF at destination
Resolution: 1°F (0.5°C) increments
Recording Intervals: 1-255 user-programmable intervals
up to 2,048 readings
Tag: ABS plastic tag with stainless steel button
Reprogrammable for multiple uses
TransTrakTM Reports & Sessions
Temperatures exceeding pre-programmed limits during transit
can be easily evaluated by a unique Transport Session report.
Out of Range
Indicator signals
immediately
if temperature limits
were exceeded
High
Temperature
Limit
Within Limit
Event
10
Accuracy: ±2°F (±1°C) from -22° to 176°F (-30° to 70°C)
Water resistant
Quick session summary display
Low
Temperature
Limit
Temperature Range: -40° to 185°F (-40° to 85°C)
Low Limit
Event
Battery: Lithium
Warranty: 1 year
Thermistor Instruments
SH66A-E 3-Zone Temperature Instrument
For applications when multiple temperature measurements are
needed, this is the instrument to use. Simultaneously measure
suction and liquid line temperatures, as well as temperatures
across condensing coils, evaporator coils and ambient
temperatures. View temperature differential between zones
1 and 2 and review min/max temperatures from all three zones.
Features include: a backlit display for dark environments; a sealed
keypad which protects the instrument from spills and dust; and a
battery eliminator jack. (Specifications are on Page 12.)
SH66A-E:
• 1075 General Purpose Puncture Probe
• 2010 Air Probe
• 4011 Pipe Strap Probe
*SH66A-E-032:
• 1075 General Purpose Puncture Probe
• 2010 Air Probe
• 4011 Pipe Strap Probe
• Certificate of calibration traceable to NIST standards
SRH77A-E 3-Zone Temperature/Humidity Instrument
When temperature and relative humidity measurements are
critical, the SRH77A-E is the expert’s choice. View temperature
differential, %RH and wet-bulb. You will find this to be an accurate
and fast service tool. Features include: a backlit display for dark
environments; sealed keypad which protects the instrument from
spills and dust; and a battery eliminator jack. The bright blue,
durable carrying case makes this tool easy to find when on location
or in the back of a service truck. (Specifications are on Page 12)
SRH77A-E:
• 1075 General Purpose Puncture Probe
• 4011 Pipe Strap Probe
• 5028 Slim Humidity Probe
*SRH77A-E-032:
• 1075 General Purpose Puncture Probe
• 4011 Pipe Strap Probe
• 5028 Slim Humidity Probe
• Certificate of calibration traceable to NIST standards
1075
1075
2010
5028
4011
4011
4005i
Cordless Pipe Clamp Temperature Instrument
Includes 2.5” (64 mm) Retractable General Purpose Puncture Probe.
Measure temperature of pipes up to 1.375” (35 mm) diameter.
• Single-handed Use
• Spring-loaded Probe to Ensure Repeatability
• Auto shut-off After 5 Minutes of Non-use
• Mode Button: Min, Max and Hold
• Nylon, Belt-pouch (included)
*Cooper-Atkins thermistor instruments are calibrated
to temperature, electrical and/or resistance standards
maintained by the company. The measurement results
obtained through these standards are traceable to the
U.S. Department of Commerce, National Institute of
Standards and Technology (NIST). Used in HVAC/R
applications where IAQ (Indoor Air Quality) and accuracy of measurements are critical to healthy environment indoor conditions and product safety such as hospitals, labs, schools, refrigeration of products and energy
consumption.
4005i
11
Thermistor Instruments
TM99A Series
Thermistor Temperature Instrument
For applications where only one temperature
is needed. It features Min/Max Memory, Hold,
Auto-shutoff and an LCD backlight for dark
environments.
TM99A
TM99A:
• 1075 General Purpose Puncture Probe
• 9339 Soft, Carrying/Storage Pouch
TM99A-032:
• 1075 General Purpose Puncture Probe
• 9339 Soft, Carrying/Storage Pouch
• Certificate of calibration traceable to
NIST standards
TM99A-V:
• 1050 Blunt-tip Veterinary Probe
• 9339 Soft, Carrying/Storage Pouch
Temperature Range:
Accuracy:
Humidity Range:
Humidity Accuracy:
SH66A/SH66A-E-032
SRH77A/SRH77A-E-032
TM99A/TM99A-032
4005i
-40° to 300°F
(-40° to 150°C)
-40° to 300°F
(-40° to 150°C)
-40° to 302°F
(-40° to 150°C)
-20° to 300°F
(-29° to 149°C)
±0.3°F (0.2°C)
OR ±0.5% Rdg.
whichever is greater
±0.3°F (0.2°C)
OR ±0.5% Rdg.
whichever is greater
±0.3°F (0.2°C)
OR ±0.5% Rdg.
whichever is greater
Clamp:
±3°F (2°C) from 14° to 212°F
(-10° to 100°C),
Probe: ±3°F (2°C)
-
10 to 95% RH
-
-
-
±2% from 20 to 80% RH
±3% below 20% and above 80% RH
-
-
0.1°
0.1°
1% RH
0.1°
0.1°
2” x .875” (51 mm x 22 mm)
2” x .875” (51 mm x 22 mm)
.5” (13 mm)
.25”x .875” (6 mm x 22 mm)
Backlight:
Yes
Yes
Yes
No
Min / Max:
Yes
Yes
Yes
Yes
Hold:
No
No
Yes
Yes
0° to 130°F (-18° to 54°C)
Up to 90% RH
non-condensing
0° to 130°F (-18° to 54°C)
Up to 90% RH
non-condensing
32° to 122°F (0° to 50°C)
0° to 120°F
Up to 90% RH
non-condensing
Polyetheylene
Polyetheylene
ABS
Plastic
Weight:
1 lb 5 oz (595 g)
1 lb 5 oz (595 g)
5 oz (142 g)
5 oz (142 g)
Power:
(1) 9V Alkaline
(1) 9V Alkaline
(2) AAA Alkaline
(1) 1.5V LR44
Yes (after 15 mins)
Yes (after 15 mins)
Yes (after 5 mins)
Yes (after 5 mins)
90 hours
90 hours
1800 hours
90 hours
5 year instrument/1 year probe
5 year instrument/1 year probe
5 year instrument/1 year probe
1 year
Resolution:
Display - LCD:
Ambient Operating Range:
Case Material:
Auto Shut-off:
Battery Life:
Regulatory Listings:
Warranty:
12
Thermistor Probes
Needle Probes
All Thermistor Temperature Probes are interchangeable with all Cooper-Atkins Thermistor Instruments.
1013
1014
1030
1050
1052
1075
1078
6000
Needle
Probe
General Purpose
Puncture Probe
7” Puncture Probe
18” Flexible
Thermistor Probe
Meat-Packing
Puncture Probe
17” Puncture
Probe
Screw-in
Puncture Probe
Blunt-tip
Veterinary
Probe
Temperature Range:
-40° to 300°F
(-40° to 149°C)
-40° to 300°F
(-40° to 149°C)
-40° to 300°F
(-40° to 149°C)
-40° to 300°F
(-40° to 149°C)
-40° to 300°F
(-40° to 149°C)
-40° to 300°F
(-40° to 149°C)
-40° to 300°F
(-40° to 149°C)
-25° to 200°F
(-40° to 93°C)
Max Tip
Temperature:
300°F (149°C)
300°F (149°C)
300°F (149°C)
300°F (149°C)
300°F (149°C)
300°F (149°C)
300°F (149°C)
200°F (93°C)
Max Cord
Temperature:
200°F (93°C)
200°F (93°C)
400°F (204°C)
200°F (93°C)
200°F (93°C)
200°F (93°C)
200°F (93°C)
200°F (93°C)
6 seconds
100 seconds
20 seconds
6 seconds
4 seconds
6 seconds
6 seconds
50 seconds
Shaft Length:
3.75” (95 mm)
17” (430 mm)
2.5” (64 mm)
3.5” (89 mm)
2.9” (74 mm)
3.75” (95 mm)
7” (178 mm)
18” (457 mm)
Shaft Diameter:
0.140” (4 mm)
0.25” (6 mm)
0.165” (4 mm)
0.125” (3 mm)
0.041” (1 mm)
0.146” (3.6 mm)
0.140” (4 mm)
0.156” (4 mm)
6’ (1.8 m)
polyurethane
(uncoiled)
6’ (1.8 m)
polyurethane
(uncoiled)
6’ (1.8 m)
polyurethane
(straight)
6’ (1.8 m)
polyurethane
(uncoiled)
6’ (1.8 m)
polyurethane
(uncoiled)
6’ (1.8 m)
polyurethane
(uncoiled)
6’ (1.8 m)
polyurethane
(uncoiled)
12’ (3.7 m)
PVC
(straight )
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
Description:
Response Time (liquid):
Cord Length:
Warranty:
1013
Meat-Packing Puncture Probe
1014
17” Puncture Probe with Heavy-Duty Cord
1050
Blunt-Tip Veterinary Probe
1052
Needle Probe
(use with Pete’s Plugs)
1030
Screw-in Probe with 1/8” NPT Fitting
1078
7” Puncture Probe
1075
General Purpose Puncture Probe
Surface Probes
Air Probes
3010
4005
4011
4040
7010
2007
2010
5005
5028
Description:
Plastic Shaft
Probe
Pipe Clamp
Probe
Pipe Strap
Probe
Fast
Response
Surface
Probe
Air/Surface
Probe
Blunt Tip
Veterinary
Probe
Air
Probe
Air
Probe
Slim Temp/
Humidity
Probe
Temperature
Range:
-40° to 200°F
(-40° to 93°C)
-14° to 212°F
(-10° to 100°C)
-25° to 212°F
(-32° to 100°C)
-40° to 212°F
(-40° to 100°C)
-40° to 200°F
(-40° to 93°C)
-40° to 300°F
(-40° to 149°C)
-40° to 200°F
(-40° to 93°C)
-40° to 300°F
(-40° to 149°C)
0° to 150°F
(-18° to 66°C)
-
-
-
-
-
-
-
-
10 to 95% RH
Max Tip
Temperature:
200°F (93°C)
200°F (93°C)
212°F (100°C)
212°F (100°C)
200°F (93°C)
300°F (149°C)
200°F (93°C)
300°F (149°C)
150°F (66°C)
Max Cord
Temperature:
200°F (93°C)
200°F (93°C)
200°F (93°C)
200°F (93°C)
200°F (93°C)
400°F (204°C)
200°F (93°C)
200°F (93°C)
200°F (93°C)
15
seconds
12
seconds
-
15
seconds
20
seconds
6
seconds
20
seconds
-
30
seconds
3” (76 mm)
-
-
3.5” (89 mm)
0.160” (4 mm)
4” (102 mm)
0.5” (13 mm)
4” (102 mm)
4.9” (125 mm)
0.156” (4 mm)
-
-
0.310” (Tip)
(8 mm)
0.5” (13 mm)
0.140” (4 mm)
0.160” (4 mm)
0.125” (3 mm)
0.25” (6 mm)
6’ (1.8 m)
polyurethane
(uncoiled)
10’ (3 m)
TPE
(uncoiled)
12’ (3.7 m)
polyurethane
(uncoiled)
6’ (1.8 m)
polyurethane
(uncoiled)
6” (152 mm)
PVC cord
(straight )
10’ (3.0 m)
PTFE
(straight)
12’ (3.6 m)
polyurethane
(straight)
6’ (1.8 m)
polyurethane
(uncoiled)
6’ (1.8 m)
PVC
(uncoiled)
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
Humidity Range:
Response Time:
Shaft Length:
Shaft Dia.
Cord Length:
Warranty:
2007
Blunt Tip
Veterinary Probe
2010
Air Probe
4011
Pipe Strap Probe
(Strap, 11” Long x 1/2” Wide approx.)
4040
Fast Response Surface Probe
4005
Pipe Clamp Probe
(Maximum 1-3/8” Ø
Pipe Clamp Opening)
9010 10 ft./ 9015 50 ft.
Extension Cable
5028
Slim Temp/Humidity Probe
13
Dual Input Thermocouple Kits
The TD2000 is a dual-input, Type K thermocouple instrument designed to monitor two zones simultaneously. The TD2000 is ideal for
monitoring in/out flow lines of cooling and heating units and displays Max temperature and Delta-T calculations. It includes a protective
rubber boot and has a temperature range up to 2000°F. The TD2000-01 Kit includes two Bead Tip probes and a Needle probe (for internal
measurement of liquids or solids). The TD2000-02 Kit includes two 54011-K Pipe Strap Surface probes and a soft carrying pouch.
TD2000-01
TD2000-02
-58° to 2000°F
(-50° to 1093°C)
-58° to 2000°F
(-50° to 1093°C)
±4°F (2°C) from
-58° to 32°F (-50° to 0°C)
±0.3% +2°F (1°C) from
32° to 2000°F (0°C to 1093°C)
±4°F (2°C) from
-58° to 32°F (-50° to 0°C)
±0.3% +2°F (1°C) from
32° to 2000°F (0°C to 1093°C)
1°
1°
Housing:
ABS
ABS
Hold:
Yes
Yes
Backlight:
No
No
Temperature
Range:
Accuracy:
Resolution:
Waterproof:
Power:
Battery Life:
No
No
(1) 9V
(3) 1.5V AAA
200 hours
200 hours
Auto Off:
10 min.
10 min.
Weight:
10.7 oz (303 g)
10.7 oz (303 g)
5-year Inst./ 1-year probe
5-year Inst./ 1-year probe
Regulatory
Listings:
Warranty:
TD2000-01
Dual Input Thermocouple Kit
• TD2000 Thermocouple Instrument
• (2) 6030MK Bead Tip Probes
• 31901-K Needle Probe
14
TD2000-02
Dual Input Thermocouple Kit
• TD2000 Thermocouple Instrument
• (2) 54011-K Pipe Strap Surface Probes
• 14057 Soft Pouch
EconoTemp™ Thermocouple Instruments
The EconoTemp™ series employs state-of-the-art technology in economy thermocouple instruments. Designed with a powerful
microprocessor and a unique memory which stores calibration settings, it will never need recalibration. A rubber boot protects
the ABS plastic housing delivering impact ratings not found in other economy models. Supplied with a 9368 Wall-mount bracket
and lanyard.
32311-K
32322-K
Temperature
Range:
-40° to 500°F
(-40° to 260°C)
-40° to 1000°F
(-40° to 538°C)
Accuracy:
±1°F (±0.5°C)
±1°F (±0.5°C)
1°
1.0 / 0.1°
Housing:
ABS
ABS
Hold:
No
No
Backlight:
No
No
Resolution:
Waterproof:
No
No
Power:
(3) 1.5V AAA
(3) 1.5V AAA
Battery Life:
4500 hours
4500 hours
10 min.
10 min.
Yes
Yes
6 oz (170 g)
6 oz (170 g)
5-year Inst./ 1-year probe
5-year Inst./ 1-year probe
Auto Off:
Wall Mounting
Bracket:
Weight:
32311-K
EconoTempTM
32322-K
EconoTempTM Plus
• High temperature range
• 10th degree resolution
up to 495ºF (257ºC)
Regulatory
Listings:
Warranty:
94020-K
EconoTempTM Direct Connect
Combo Pack
• 32311-K Thermocouple
Instrument
• 50337-K Direct Connect
DuraNeedle Probe
• Wall-mount bracket
• Response Time: 1 second
93230-K
EconoTempTM Combo Pack
• 32311-K Thermocouple
Instrument
• 50336-K DuraNeedle Probe
• Wall-mount bracket
• Response Time: 2 seconds
15
AquaTuff™ Thermocouple Instruments
AquaTuff™ Wrap&Stow™ Thermocouple Instruments have a unique memory chip that stores calibration settings. They are highly accurate,
NIST traceable and most importantly, as the AquaTuff™ name implies, extremely durable and IPX7 waterproof rated for even greater reliability
in harsh environments. Integral probe and cable storage enclosure designs are available where the probe is factory calibrated to the
instrument. The AquaTuff™ 35100-K or 35200-K allow for maximum versatility since the instrument can be used with any Type K
Thermocouple probes.
35100-K
AquaTuff™
35132
AquaTuff™ Wrap&Stow™
35135
AquaTuff™ Wrap&Stow™
35140
AquaTuff™ Wrap&Stow™
with DuraNeedle™ Probe
with Angled Surface Probe
with MicroNeedle Probe
AquaTuff ™ 351 Series
AquaTuff™ Series
Wrap&Stow™ Probes
DuraNeedle Probes are best used to measure
insertion and immersion temperatures. They are
quick and durable for dependable performance,
and are included with the 35132 and 35232.
To order replacement DuraNeedle Probes,
use model number 55032.
35100-K
35132
35135
35140
-100° to 999°F
(-73° to 537°C)
-100° to 500°F
(-73° to 260°C)
-100° to 500°F
(-73° to 260°C)
-100° to 500°F
(-73° to 260°C)
±0.5°F (±0.3°C)
±0.9°F (±0.5°C) [1]
Total System
±0.5°F (±0.3°C) [3]
±0.9°F (±0.5°C) [1]
Total System
Resolution:
0.1°
0.1°
0.1°
0.1°
Housing:
ABS
ABS
ABS
ABS
Hold:
No
No
No
No
Backlight:
No
No
No
No
Temperature
Range:
Accuracy:
Waterproof:
MicroNeedle Probes are designed to provide
the greatest response times with minimal impact
on the product, and are included with the 35140
and 35240 and 35340. To order replacement
MicroNeedle Probes, use model number 55040.
Yes
Yes
Yes
Yes
Power:
(2) 1.5V AAA
(2) 1.5V AAA
(2) 1.5V AAA
(2) 1.5V AAA
Battery Life:
1800 hours
1800 hours
1800 hours
1800 hours
Auto Off:
10 min.
10 min.
10 min.
10 min.
Wall Mounting
Bracket:
Optional
Optional
Optional
Optional
5 oz (142 g)
7 oz (199 g)
8 oz (227 g)
7 oz (199 g)
5 year
5 year instrument/
1 year probe
5 year instrument/
1 year probe
5 year instrument/
1 year probe
Weight:
Surface Probes are designed for use on any
flat surface. Probe self-adjusts to the surface,
giving superior contact and is included with the
35135 and 35235. To order replacement
Surface Probes, use model number 55035.
16
Regulatory
Listings:
Warranty:
NOTE:
All EconoTempTM Series and AquaTuff™ Series units are traceable to NIST standards.
[1] Total System Accuracy™ (probe and instrument) over entire range.
[2] Tenth degree/whole degree resolution, selectable.
[3] Accuracy spec for instrument only. Surface probe temperature error for flat, clean,
oiled surfaces with 1kg pressure are typically within +1.5°C and -3.5°C without
thermostat cycling.
AquaTuff™ Thermocouple Instruments
35232
AquaTuff™ Wrap&Stow™
35200-K
AquaTuff™
with DuraNeedle™ Probe
35240
AquaTuff™ Wrap&Stow™
with MicroNeedle Probe
AquaTuff ™ 352/353 Series
35200-K
35232
35235
35240
-100° to 999°F
(-73° to 537°C)
-100° to 500°F
(-73° to 260°C)
-100° to 500°F
(-73° to 260°C)
-100° to 500°F
(-73° to 260°C)
±0.5°F (±0.3°C)
±0.9°F (±0.5°C) [1]
Total System
±0.5°F (±0.3°C) [3]
±0.9°F (±0.5°C) [1]
Total System
0.1° [2]
0.1° [2]
0.1° [2]
0.1° [2]
Housing:
ABS
ABS
ABS
ABS
Hold:
Yes
Yes
Yes
Yes
Backlight:
Yes
Yes
Yes
Yes
Waterproof:
Yes
Yes
Yes
Yes
Power:
(2) 1.5V AAA
(2) 1.5V AAA
(2) 1.5V AAA
(2) 1.5V AAA
Battery Life:
Temperature
Range:
Accuracy:
Resolution:
1800 hours
1800 hours
1800 hours
1800 hours
Auto Off:
10 min.
10 min.
10 min.
10 min.
Wall Mounting
Bracket:
Optional
Optional
Optional
Optional
5 oz (142 g)
7 oz (199 g)
8 oz (227 g)
7 oz (199 g)
5 year
5 year instrument/1 year probe
5 year instrusment/
1 year probe
5 year instrument/
1 year probe
Weight:
Regulatory
Listings:
Warranty:
IPX7
Waterproof
All the AquaTuff™
instruments are IPX7
waterproof rated and
durable for harsh
environments.
An IPX7 level reading
means the instrument
can be submerged in
1 meter of water for
30 minutes without
water damage.
93916-K
Screen Print Kit
• 35200-K AquaTuff™ Thermocuple Instrument
• 50008-K Screen Print Donut Probe with 15’ Cord
• 10830 Spare Wires
• 14235 Hard Carrying Case
17
Type K Thermocouple Probes
Cooper-Atkins builds all of our probes in our Connecticut Headquarters facility, so you can rely on us to custom design and manufacture
a probe for your specific needs. Cooper-Atkins probes are manufactured in an ISO 9001-2008 facility in the United States.
Needle Probes
31901-K
39035-K
49122-K
49135-K
50101-K
50143-K
50145-K
50207-K
Description:
1/8” Needle
Probe (Petite Handle)
1/8” Needle
Probe
Ultra-Fine
Product
Probe
1/8” Rugged
Needle Probe
Frozen Product
Needle Probe
Heavy-Duty
Needle Probe
1/8” Rugged
Needle Probe
MicroNeedle
Chisel Tip
Probe
(Direct Connect)
Temperature
Range:
-40° to 400°F
(-40° to 205°C)
-40° to 400°F
(-40° to 205°C)
-100° to 500°F
(-73° to 260°C)
-40° to 400°F
(-40° to 205°C)
-40° to 400°F
(-40° to 205°C)
-40° to 500°F
(-40° to 260°C)
-40° to 500°F
(-40° to 260°C)
-100° to 500°F
(-73° to 260°C)
Max Tip
Temperature:
400°F (205°C)
400°F (205°C)
500°F (260°C)
400°F (205°C)
400°F (205°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
Max Cable
Temperature:
400°F (205°C)
400°F (205°C)
221°F (105°C)
400°F (205°C)
400°F (205°C)
176°F (80°C)
176°F (80°C)
-
4 seconds
4 seconds
3 seconds
4 seconds
4 seconds
5 seconds
4 seconds
1 second
Response Time
(liquid):
50336-K
DuraNeedle
Probe
Shaft Length:
4” (102 mm)
4” (102 mm)
4” (102 mm)
4” (102 mm)
3” (76 mm)
4” (102 mm)
4” (102 mm)
3.75” (95 mm)
Cable Length
Max Extended:
24” (610 mm)
w/ Silicone
Jacket
36” (914 mm)
w/ FEP
Jacket
36” (914 mm)
w/ PVC
Jacket
36” (914 mm)
w/ FEP
Jacket
30” (762 mm)
w/ Flexible
Armored Cable
48” (1.2 m)
w/ Polyurethane
Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
Direct
Connect
(no cable)
1 oz (28 g)
1 oz (28 g)
1 oz (28 g)
4 oz (113 g)
1 lb (454 g)
5 oz (142 g)
4 oz (113 g)
0.5 oz (14 g)
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
50334-K
50335-K
50336-K
50337-K
50360-K
50361-K
Oven Needle
Probe
Meat
Probe
Weight:
Warranty:
50012-K
Angled Shaft
Surface Bell
Probe
Needle Probes
50209-K
50210-K
Description:
MicroNeedle
Probe
MicroNeedle
Probe
(Direct Connect)
60° Patty
Probe
4” DuraNeedle
Probe
4.5” Needle
Probe
DuraNeedle
Probe
DuraNeedle
Probe
(Direct Connect)
Temperature
Range:
-100° to 500°F
(-73° to 260°C)
-100° to 500°F
(-73° to 260°C)
-100° to 500°F
(-73° to 260°C)
-100° to 500°F
(-73° to 260°C)
-40° to 500°F
(-40° to 260°C)
-40° to 500°F
(-40° to 260°C)
-100° to 500°F
(-73° to 260°C)
-40° to 500°F
(-40° to 260°C)
-40° to 400°F
(-40° to 205°C)
Max Tip
Temperature:
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
400°F (205°C)
Max Cable
Temperature:
176°F (80°C)
-
176°F (80°C)
400°F (205°C)
176°F (80°C)
176°F (80°C)
-
600°F (316°C)
400°F (205°C)
Response
Time (liquid):
1 second
1 second
1 second
1 second
4 seconds
2 seconds
1 second
2 seconds
4 seconds
Shaft Length:
3.5” (89 mm)
3.75” (95 mm)
8” (203 mm)
4” (102 mm)
4.5” (114 mm)
6” (153 mm)
4” (102 mm)
5.5” (140 mm)
3.875” (98 mm)
48” (1.2 m)
w/ Polyurethane
Jacket
Direct Connect
(no cable)
48” (1.2 m)
w/ Polyurethane
Jacket
34” (864 mm)
w/ Fluoroelastomer
Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
Direct Connect
(no cable)
35” (889 m)
w/ Stainless
Steel Overbraid
10’ (3 m)
w/ Flexible Armor
2 oz (57 g)
0.5 oz (14 g)
3 oz (85 g)
2 oz (57 g)
2 oz (57 g)
2 oz (57 g)
0.5 oz (14 g)
1 oz (28 g)
6 oz (170 g)
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
Cable Length
Max Extended:
Weight:
Warranty:
50263-K
High Temperature Probes
49127-K
49140-K
Description:
Reduced Tip
Puncture
Probe
Reduced Tip
Probe
(Direct Connect)
High
Temperature
Probe
4” Reduced Tip
Probe
12” Reduced Tip
Probe
Temperature
Range:
32° to 932°F
(0° to 500°C)
32° to 932°F
(0° to 500°C)
32° to 2012°F
(0° to 1100°C)
32° to 932°F
(0° to 500°C)
Max Tip
Temperature:
932°F (500°C)
932°F (500°C)
2012°F (1100°C)
Max Cable
Temperature:
400°F (205°C)
-
1 second
liquid
Shaft Length:
4” (102 mm)
Cable Length
Max Extended:
36” (914 mm)
w/ FEP
Jacket
Response
Time:
Weight:
Warranty:
18
Pipe Probes
49126-K
50426-K
4005MK
Fry Vat Probes
54011-K
50200-K
50208-K
Pipe Clamp
Surface Probe
Pipe Strap
Surface Probe
High
Temperature
Probe
Fry Vat
Insertion
Probe
32° to 932°F
(0° to 500°C)
-20° to 300°F
(-29° to 149°C)
-25° to 300°F
(-32° to 149°C)
-40° to 400°F
(-40° to 205°C)
-40° to 400°F
(-40° to 205°C)
932°F (500°C)
932°F (500°C)
300°F (149°C)
300°F (149°C)
400°F (205°C)
400°F (205°C)
400°F (205°C)
176°F (80°C)
176°F (80°C)
220°F (104°C)
220°F (104°C)
400°F (205°C)
400°F (205°C)
1 second
liquid
2 seconds
liquid
1 second
liquid
1 second
liquid
2 seconds
on pipe
Varies
on pipe
12 seconds
liquid
8 seconds
liquid
4” (102 mm)
24” (610 mm)
4” (102 mm)
12” (305 mm)
-
-
8” (203 mm)
7.3” (185 mm)
Direct Connect
(no cable)
36” (914 mm)
w/ Flexible
Armor
48” (1.2 m)
w/ Polyurethane
Jacket
48” (1.2 m)
Polyurethane Jacket
10’ (3 m)
w/ Polyurethane
Jacket
10’ (3 m)
w/ Polyurethane
Jacket
36” (914 mm)
w/ FEP
Jacket
30” (762 mm)
w/ Flexible
Armor
4 oz (113 g)
.5 oz (14 g)
6 oz (170 g)
5 oz (142 g)
5 oz (142 g)
5 oz (142 g)
2 oz (57 g)
2 oz (57 g)
3 oz (85 g)
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
50427-K
4005MK
Pipe Clamp Probe
54011-K
Pipe Strap Probe
Air Probes
31903-K
31905-K
39032-K
49138-K
50302-K
50305-K
50306-K
50332-K
50338-K
Description:
Hand-held
Air Probe
Bare Tip
Air Probe
Hand-Held
Air Probe
Bare Tip Air
Probe
Industrial
Air Probe
Freezer/Cooler
Probe
Oven/
Freezer
Probe
Hand-Held
Air Probe
Industrial
Air Probe
Temperature
Range:
-40° to 400°F
(-40° to 205°C)
-40° to 400°F
(-40° to 205°C)
-328° to 400°F
(-200° to 205°C)
32° to 896°F
(0° to 480°C)
32° to 896°F
(0° to 480°C)
-40° to 400°F
(-40°to 205°C)
-100° to 600°F
(-73° to 316°C)
-100° to 500°F
(-73° to 260°C)
32° to 896°F
(0° to 480°C)
Max Tip
Temperature:
400°F (205°C)
400°F (205°C)
400°F (205°C)
896°F (480°C)
896°F (480°C)
400°F (205°C)
600°F (316°C)
500°F (260°C)
896°F (480°C)
Max Cable
Temperature:
400°F (205°C)
400°F (205°C)
400°F (205°C)
896°F (480°C)
896°F (480°C)
176°F (80°C)
600°F (316°C)
176°F (80°C)
896°F (480°C)
9 seconds in
5 m/sec. air
1 sec. liquid &
3 sec. 5 m/
sec. air
11 seconds in
5 m/sec. air
steam
1 second liquid
9 sec. 5 m/
sec. air
1 second liquid
10 sec. 5 m/
second air
25 seconds air
1 second liquid
10 sec. 5 m/
second air
10 seconds in
5 m/sec. air
1 second liquid
9 seconds in
5m/sec. air
Response
Time :
Shaft Length:
4” (102 mm)
-
4” (102 mm)
-
2.125” (54 mm)
-
2.125” (54 mm)
4” (102 mm)
-
Cable Length
Max Extended:
24” (610 mm)
w/ Silicone
Jacket
24” (610 mm)
w/ Silicone
Jacket
36” (914 mm)
w/ FEP
Cable
48” (1.2 m)
w / Fiberglass
Jacket
46.5” (1.2 m)
w/ Fiberglass
Jacket
24” (610 mm)
w/ FEP
Jacket
43” (1.1 m)
w/ Stainless
Steel Overbraid
48” (1.2 m)
w/ Polyurethane
Jacket
48” (1.2 m)
w / Fiberglass
Jacket
1 oz (28 g)
1 oz (28 g)
1 oz (28 g)
1 oz (28 g)
1 oz (28 g)
3 oz (85 g)
1 oz (28 g)
2 oz (57 g)
1 oz (28 g)
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
Weight:
Warranty:
50306-K
Air Probe for oven
or cooler/freezer
with clip
Surface Probes
31907-K
50001-K
50008-K
50010-K
50012-K
50014-K
50069-K
50316-K
50318-K
50319-K
50405-K
Description:
Surface
Probe - petite
handle
Right Angle
Bell Surface
Probe
Silkscreen
Probe
Tape Surface
Probe
120° Angled
Shaft
Surface Bell
Probe
Weighted
Griddle
Surface
Probe
Moving
Surface
Bow Probe
1/8” Surface/
Immersion Probe
- flat tip
Ceramic Tip
Surface Probe
90° Ceramic
Tip Surface
Probe
Blunt Tip
Probe
Temperature
Range:
-40° to 400°F
(-40° to 205°C)
-40° to 400°F
(-40° to 205°C)
-40° to 400°F
(-40° to 205°C)
-40° to 400°F
(-40° to 205°C)
-40° to 500°F
(-40° to 260°C)
-40° to 500°F
(-40° to 260°C)
-40° to 500°F
(-40° to 260°C)
-100° to 500°F
(-73° to 260°C)
-40° to 1202°F
(-40° to 650°C)
-40° to 1202°F
(-40° to 650°C)
-100° to 500°F
(-73° to 260°C)
Max Tip
Temperature:
400°F (205°C)
400°F (205°C)
400°F (205°C)
400°F (205°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
1202°F (650°C)
1202°F (650°C)
500°F (260°C)
Max Cable
Temperature:
400°F (205°C)
400°F (205°C)
400°F (205°C)
400°F (205°C)
176°F (80°C)
400°F (205°C)
221°F (105°C)
176°F (80°C)
176°F (80°C)
176°F (80°C)
-
Response
Time:
5 seconds on
(oiled surface)
7 seconds
(oiled surface)
1 second
(liquid)
9 seconds on
(metal surface)
4 seconds
(oiled surface)
2 seconds
(oiled surface)
4 seconds
(oiled surface)
6 seconds
(metal surface) /
1 second (liquid)
1 second
(oiled surface)
1 second
(oiled surface)
6 seconds
(oiled surface)
1 second (liquid)
Shaft Length:
4” (102 mm)
9” (229 mm)
-
-
4.5” (114 mm)
-
8” (203 mm)
4” (102 mm)
4” (102 mm)
5” (127 mm)
7.5” (190 mm)
Cable Length
Max Extended:
24” (610 mm)
w/ Silicone
Jacket
30” (762 mm)
w / Flexible
Armored Cable
15” (381 mm)
w/ Silicone
Jacket
36” (914 mm)
w/ FEP Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
30” (762 mm)
w / Flexible
Armored Cable
36” (914 mm)
w/ PVC
Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
Direct Connect
(no cable)
1 oz (28 g)
6 oz (170 g)
3 oz (85 g)
1 oz (28 g)
5 oz (142 g)
2 lbs (907 g)
6 oz (170 g)
2 oz (57 g)
5 oz (142 g)
6 oz (170 g)
.5 oz (14 g)
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
39138-K
49136-K
50121-K
50415-K
50701-K
52048-K
Description:
Bare-Tip
Probe
Bendable Tip
Probe
Racing Tire
Probe
Dishwasher
Probe
Combo
Probe
Product
Simulator
Temperature
Range:
-328° to 400°F
(-200° to 205°C)
32° to 1652°F
(0° to 900°C)
-40° to 500°F
(-40° to 260°C)
-67° to 221°F
(-55° to 105°C)
-100° to 500°F
(-73° to 260°C)
-40° to 180°F
(-40° to 82°C)
Max Tip
Temperature:
400°F (205°C)
1652°F (900°C)
500°F (260°C)
221°F (105°C)
500°F (260°C)
180°F (82°C)
Max Cable
Temperature:
400°F (205°C)
221°F (105°C)
176°F (80°C)
221°F (105°C)
400°F (205°C)
-
1 sec. liquid & 7
sec. 5 m / sec. air
1 second
liquid
1 second
liquid
9 seconds in
5 m / sec. air
2 seconds
liquid
Stabilization of
Simulator - up to
2 hours
-
7” (178 mm)
0.1875” (5 mm)
-
35” (889 mm)
-
36” (914 mm)
w/ FEP
Jacket
36” (914 mm)
w/ PVC
Jacket
48” (1.2 m)
w/ Polyurethane
Jacket
15’ (4.6 m)
w/ PVC
Jacket
36” (914 mm)
w/ Fluoroelastomer
Jacket
6“ (152 mm)
Flexible Cable w/
FEP Jacket
1 oz (28 g)
1 oz (28 g)
4 oz (113 g)
3 oz (85 g)
15 oz (425 g)
2.5 oz (71 g)
1 year
1 year
1 year
1 year
1 year
1 year
Weight:
Warranty:
Miscellaneous Probes
Response
Time :
Shaft Length:
Cable Length
Max Extended:
Weight:
Warranty:
52048-K
Product
Simulator
Probe
49136-K
Bendable
TipProbe
NOTE: Most probes are available in Type J and Type T configurations.
19
Digital Panel Thermometers
Cooper-Atkins’ panel meters allow you to obtain accurate interior temperature readings remotely from outside the cabinet.
They reduce the frequency of opening your cooler/freezer door and keep the cold air in and the hot air out. All are designed
for retro-fit applications.
PM180
Dual-Cool™ Panel Thermometer
SP160-0
SP120
PM120
PM180
SP160-01
• Min/Max alarm settings
• Hi/Lo temperature recall
Temperature
-58° to 158°F
-58° to 158°F
-40° to 122°F
-25° to 180°F
(-32° to 82°C)
(-50° to 70°C)
(-50° to 70°C)
(-40° to 50°C)
Range:
• Interchangeable probes
±1°F (0.5°C) from 32° to
122°F (0 to 50°C)
±2°F from -4° to 32°F (-20°
to 50°C)
±3.6°F/2°C <-4°F (-20°C)
and > 122°F (50°C)
±2°F (±1°C)
±1.8°F (±1°C) from -4° to
122°F (-20° to 50°C)
±3.6°F (±2C°) below
-4°F (20°C)
±2°F (±1°C)
0.1°
0.1°
0.1°
0.1°/1% RH
Ambient
Operating
Range:
0° to 120°F up to 90%
non-condensing
0° to 120°F up to 90%
non-condensing
0° to 120°F up to 90%
non-condensing
0° to 120°F up to 90%
non-condensing
Response
Time:
10 second updates
30 seconds
10 second updates
30 seconds
5 second updates
LCD:
1.4” x 0.5”
(36 mm x 13 mm)
1.875” x 0.625”
(48 mm x 16 mm)
1.875” x 0.625”
(48 mm x 16 mm)
1.875” x 0.625”
(48 mm x 16 mm)
48” (1.2 m)
10’ (3 m)
39” (1 m)
39” (1 m)
ABS
ABS
Polycarbonate
Polycarbonate
4.5” x 1.125” x .625”
(114 mm x 29 mm x 16 mm)
2.75” x 2.75” x .75”
(70 mm x 70 mm x 19 mm)
2.7” x 1.4” x 1.1”
(69 mm x 36 mm x 28 mm)
2.75” x 1.5” x 1”
(70 mm x 38 mm x 25 mm)
Solar w/ battery back-up
(1) 1.5V AAA
Solar w/ battery back-up
(1) 1.5V A76
(1) 1.5V AA
(1) 1.5V AA
Hangs
Hangs
Optional Mounting Flange
(Model 9302)
Hangs of Stands
3 oz (85 g)
2.5 oz (71 g)
2 oz (57 g)
5 oz (142 g)
1 year
1 year
1 year
1 year
Accuracy:
Resolution:
Lead Length:
Case Material:
Case
Dimensions:
Power:
Mounting:
Weight:
Regulatory
Listings:
Warranty:
SP Series Solar Powered Instruments
Meter operates using ambient light (natural, fluorescent and incandescent)
and have a Lux rating above 100. When the ambient light is not strong
enough to power the meter, the 1.5V battery automatically turns the backlight unit on.
SP160-0
Solar Powered
Panel Meter
• 4’ cord
• Black case
SP160-1
Solar Powered
Panel Meter
• 4’ cord
• White case
PM180-01
• PM180 Panel Thermometer
• 2013 Air Probe
• 2113 Solid Simulator Probe
PM180-02
• PM180 Panel Thermometer
• (2) 2013 Air Probe
PM180-03
• PM180 Panel Thermometer
• (2) 2113 Solid Simulator Probe
SP120
Solar Powered
Panel Meter
• 10’ cord
PM120
Mini Remote-Reading
Thermometer
For use when mounting
space is limited.
• Min/Max feature
• 9302 Mounting
flange available
NOTE: PM120 & PM180
are not solar powered
instruments
20
Digital Panel Thermometers
PMRH120
DM120
Series
DM450
DTT361
Temperature
Range:
-12° to 140°F
(-24° to 60°C)
-40° to 120°F
(-40° to 48°C)
-40° to 450°F
(-40° to 230°C)
-25° to 392°F
(31° to 200°C)
Accuracy:
±2°F (±1°C)
±5% RH from
30° to 75%RH/
at 32° to 122°F
(0° to 50°C)
±2°F (±1°C)
±2°F (±1°C) from -40°
to 300°F
±2% of reading from 301°
to 450°F
±2°F (±1°C) from -4° to 302°F
(-20°C to 150°C) ±3°F (±1.5°C)
outside range
0.1°/1% RH
0.1°
0.1°
0.1°
Ambient
Operating
Range:
0° to 120°F up to 90%
non-condensing
15° to 150°F up to 90%
non-condensing
0° to 150°F up to 90%
non-condensing
32° to 122°F (0° to 50°C) / 20
to 90%RH
Response
Time:
5 seconds
30 second updates
30 seconds
10 second updates
-
1.875” x 0.625”
(48 mm x 16 mm)
1.3” x 0.5”
(33 mm x 13 mm)
1.3” x 0.5”
(33 mm x 13 mm)
2.25” x 1.5”
(57mm x 38mm)
39” (1 m)
39” (1 m)
39” (1 m)
44” (1.1 m)
Polycarbonate
Stainless Steel
Stainless Steel
ABS Plastic
2.75” x 1.5” x 1”
(70 mm x 38 mm x 25 mm)
DM120
3.0” x 1.375” (76 mm x 27 mm)
DM120S
3.47” x 1.1” (88 mm x 28 mm)
DM450
3.0” x 1.375”
(76 mm x 27 mm)
3” x 1.30” X 4.12”
(76mm x 33mm x 105mm {without
probe})
(1) 1.5V AA
(1) 1.5V #LR754
(1) 1.5V #LR754
(3) AAA
Optional Front Flange
DM120 Front Flange
DM120S Back Flange
Front Flange
Wire hanger with magnet
2.5 oz (71 g)
DM120
2.5 oz (71 g)
DM120S
3.5 oz (999 g)
3 oz (85 g)
7oz (198g{including probe})
1 year
1 year
1 year
1 year
Resolution:
LCD:
Lead Length:
Case Material:
Case
Dimensions:
Power:
Mounting:
Weight:
PMRH120
Mini Remote-Reading
Thermometer/Hygrometer
• Min/Max feature
• 9302 Mounting flange available
DM120/DM450 Series
Front flange for flush mounting or back
flange for surface mounting to cabinet
and/or enclosure. The removable 2”
(51 mm) diameter polycarbonate lens
makes battery replacement easy.
Regulatory
Listings:
Warranty:
DM120
Front Flange Back Connect
Panel Thermometer
DTT361-01
Cooking Thermo/Timer
• Wall-mount bracket with magnet
• Temperature/Time/Alarm
• Water resistant (IPX 4)
DM450
Front Flange Back Connect
Panel Thermometer
21
Vapor Tension Panel Thermometers
Used in many HVAC/R applications, these units are the perfect choice for use in walk-in refrigerators, tanks, refrigerated display cases,
holding and specialty cabinets, dairy cases, freezers, floral displays and much more. They are able to obtain interior temperature
readings remotely from outside of the cabinet and can be retro-fitted.
• Nickel/tin-plated bulb and capillary
• Polycarbonate lens/bezel
• Stainless steel cases
6142-06
6142-13
6142-20
6142-58
40° to 240°F
(10° to 115°C)
-40° to 120°F
(-40 to 50°C)
-40° to 60°F
(-40° to 15°C)
-40° to 60°F
(-40° to 15°C)
±2°F (±1°C) from
140° to 210°F
(60 to 99°C)
±2°F (±1°) at 10° and
40°F (-12° and 4.5°C)
±5°F (±2.5°C) at
110°F (43°C)
±2°F (±1°C) at 10° to
40°F (-12° to 4.5°C)
±2°F (±1°C) at 10° to
40°F (-12° to 4.5°C)
Dial Dimension:
2” (51 mm)
2” (51 mm)
2” (51 mm)
2” (51 mm)
Capillary Length:
48” (1.2 m)
48” (1.2 m)
48” (1.2 m)
20’ (6.1 m)
Flange:
Front
Front
Front
Front
Connection:
Back
Back
Back
Back
Temperature
Range:
Accuracy:
6142-20
Front Flange
Back Connect Panel
Thermometer
Mounting:
Weight:
Flush
Flush
Flush
5 oz (142 g)
5 oz (142 g)
7 oz (198 g)
1 year
1 year
1 year
1 year
Regulatory
Listings:
6642-12
Remote Vapor Tension
Panel Thermometer
Warranty:
6642-06
6642-12
6742-19
6812-01
6812-02
-40° to 60°F
(-40° to 15°C)
40° to 240°F
(10 to 115°C)
-40° to 60°F
(-40° to 15°C)
-40° to 60°F
(-40° to 15°C)
-40° to 120°F
(-40° to 50°C)
±2°F (±1°C) at 10° to
40°F (-12° and 4.5°C)
±2°F (±1°C) from
140° to 210°F
(60° to 99°C)
±2°F (±1°C) at 10° to
40°F (-12° and 4.5°C)
±2°F (±1°C) at 10° to
40°F (-12° to 4.5°C)
±2°F (±1°C) at 10° to
40°F (-12° and 4.5°C)
±5°F (±2.5°C) at
110°F (43°C)
Dial Dimension:
2” (51 mm)
2” (51 mm)
2” (51 mm)
2” (51 mm)
2” (51 mm)
Capillary Length:
48” (1.2 m)
48” (1.2 m)
48” (1.2 m)
48” (1.2 m)
48” (1.2 m)
Flange:
Strap Hanger
no flange
Strap Hanger
no flange
U-Bracket
no flange
Back
Back
Bottom
Bottom
Back
Back
Back
Temperature
Range:
Accuracy:
6742-19
U Bracket Back
Connect Panel
Thermometer
Flush
5 oz (142 g)
Connection:
Mounting:
Weight:
-
-
-
Surface
Surface
5 oz (142 g)
5 oz (142 g)
5.6 oz (158.9 g)
5 oz (142 g)
5 oz (142 g)
1 year
1 year
1 year
1 year
1 year
Regulatory
Listings:
Warranty:
6812-02
Back Flange Back
Connect Panel
Thermometer
7112-01
7112-02
7112-05
7612-06
-40° to 60°F
(-40° to 15°C)
-40° to 120°F
(-40 to 50°C)
40° to 240°F
(10° to 115°C)
-40° to 60°F
(-40° to 15°C)
±2°F (±1°C) at 10° to 40°F
(-12° to 4.5°C)
±2°F (±1°C) at 10° and 40°F
(-12° and 4.5°C)
±5°F (2.5°C) at 110° (-43°C)
±2°F (±1°C) from
140° to 210°F
(60° to 99°C)
±2°F (±1°C) at 10° to
40°F (-12° and 4.5°C)
Dial Dimension:
2.5” (64 mm)
2.5” (64 mm)
2.5” (64 mm)
2.5” (64 mm)
Capillary Length
48” (1.2 m)
48” (1.2 m)
48” (1.2 m)
48” (1.2 m)
Flange:
Front
Front
Front
Strap Hanger
Connection:
Back
Back
Back
Bottom
Temperature
Range:
Accuracy:
Mounting:
7112-05
Front Flange Back
Connect Panel
Thermometer
22
Weight:
Flush
Flush
Flush
-
7 oz (198 g)
7 oz (198 g)
7 oz (198 g)
5.6 oz (159 g)
1 year
1 year
1 year
1 year
Regulatory
Listings:
Warranty:
Bi-Metal Thermometers
To ensure accuracy
minimum insertion
point 2” (51 mm)
1246-02
Bi-metal Stem
Test Thermometer
Adjustment
Wrench
Antimicrobial
CT180-51
Pocket Test Thermometer
The antimicrobial additive does not protect users
or others against food bacteria. Always wash, rinse
and sanitize this product thoroughly before and after
each use.
All 1” Pocket-tests are field adjustable and include a red, protective sheath with calibration wrench made with antimicrobial plastic.
1246 Series
Temperature
Range:
1246-01:
1246-01C:
1246-02:
1246-02C:
1246-03:
1246-03C:
Accuracy:
-40° to 180°F
-40° to 80°C
0° to 220°F
-20° to 100°C
50° to 550°F
10° to 285°C
1246-01:
1246-01C:
1246-02:
1246-02C:
1246-03:
1246-03C:
CT Series
2236-02
2238-06
2238-14
CT180-51: -40° to 180°F
CT220-51: 0° to 220°F
-40° to 180°F
(-40° to 80°C)
0° to 220°F
(-10° to 100°C)
50° to 550°F
(10° to 288°C)
±2°F
±2°F (±1°C)
±2°F (±1°C)
±5°F (±3°C)
±2°F
±1°C
±2°F
±1°C
±5°F
±3°C
Dial Diameter:
1” (25 mm)
1” (25 mm)
2” (50 mm)
2” (50 mm)
2” (50 mm)
Lens Material:
Magnifying
Polycarbonate
Magnifying
Polycarbonate
Tempered Glass
Tempered Glass
Tempered Glass
Stem Length:
5” (127 mm)
5” (127 mm)
5” (127 mm)
8” (203 mm)
8” (203 mm)
Weight:
0.5 oz (14 g)
11 oz (312 g)
1.5 oz (43 g)
1.2 oz (35.4 g)
1.5 oz (43 g)
-
-
1 year
1 year
1 year
1 year
Regulatory
Listings:
Warranty:
1 year
2238-06
Stem-Test Thermometer
• Vessel clip included
Developed for through-wall mounting, all units have a bi-metal coil movement and glass lens with a 0.25” (6.35 mm) diameter
stainless steel stem. The stainless steel, back flange bezel has three, equally spaced mounting holes 0.150” (3.81 mm) diameter on
a 2.9” (74 mm) diameter bolt circle.
2225 Series
2245 Series
2255 Series
Temperature Range:
2225-02: 0° to 220°F
2225-03: -40° to 160°F
2225-20: 200° to 1000°F
(100° to 500°C)
2245-02: 0° to 220°F
2245-03: -40 to 160°C
2255-02: 0° to 220°F
2255-03: -40 to 160°C
Accuracy:
2225-02: ±2°F
2225-03: ±3°F
2225-20: ±20°F (±10°C)
2245-02: ±2°F
2245-03: ±3°F
2255-02: ±2°F
2255-03: ±3°F
2” (50 mm)
2” (50 mm)
2” (50 mm)
2225-02: 3.5” (89 mm)
2225-03: 3.5” (89 mm)
2225-20: 3.5” (89 mm)
3.5” (89 mm)
3.5” (89 mm)
Stem Length:
4” (102 mm)
6” (152 mm)
9” (229 mm)
Weight:
2.5 oz (71 g)
3 oz (85 g)
3.8 oz (108 g)
1 year
1 year
1 year
Dial Dimension:
Outer Flange Diameter:
Warranty:
2225-20
Pizza Oven Flange Mount
Thermometer - Dual Scale
23
AFL Digital Pocket Test Thermometers
A digital pocket-test thermometer that is “Accurate for Life” and does NOT require any field
adjustment. Eliminating field adjustment removes the risk of introducing inaccuracy into the
instrument. Cooper-Atkins brings this industry leading advancement with the guarantee that
our Digital Pocket Tests are always accurate. Look for the logo
on Cooper-Atkins products
and you’ll know they are Accurate for Life…GUARANTEED!!
Cooper-Atkins offers a wide range of fast-response, Accurate for Life, Digital Pocket Tests with
0.1° resolution. Thermistor sensors are located in the probe tip for quick response time and
accurate readings.
DPP400W
Pen-Style Digital
Pocket Test Thermometer
• Min, Max & Hold temperature
• IPX7 waterproof rated
DFP450W
Digital Pocket Test
with Temperature Alarm
• Min/Max & Hold
Temperature
• IPX7 Waterproof rated
• Dishwasher safe
DPP800W
MAX Digital Pocket
Test Thermometer
• Large EZ-read
LCD screen
• IPX7 Waterproof rated
• Dishwasher safe
TTM41 & TTM41-10
Cooling Validator
Validator with 15” stem (TTM41)
or 10” stem (TTM41-10) tracks
elapsed time while it monitors the
temperature of the food
being cooled.
• Adjustable vessel clip
• Water-resistant
Antimicrobial
The antimicrobial additive does not protect users or others against food
bacteria. Always wash, rinse and sanitize this product thoroughly before
and after each use.
24
IPX7
Waterproof
All the Accurate for
Life Pocket Test
instruments are IPX7
waterproof rated and
durable for harsh
environments.
An IPX7 level reading
means the instrument
can be submerged in
1 meter of water for 30
minutes without water
damage.
Digital Pocket Test Thermometers
DFP450W
DPP400W
DPP800W
DPS300-01
DT300
TTM41
TTM41-10
-40° to 450°F
(-40° to 232°C)
-40° to 392°F
(-40° to 200°C)
-40° to 450°F
(-40° to 232°C)
-40° to 302°F
(-40° to 150°C)
-40° to 302°F
(-40° to 150°C)
-4° to 302°F
(-20° to 150°C)
-4° to 302°F
(-20° to 150°C)
±2°F (±1°C)
±2°F (±1°C)
±1°F (±0.5°C)
±2°F (±1°C)
±2°F (±1°C)
±2°F (±1°C)
±2°F (±1°C)
0.1°F
0.1°F
0.1°F
0.1°F
0.1°F
0.1°F
0.1°F
Display - LCD
.875” (22 mm)
.875” (22 mm)
1.5” (38 mm)
.50” (13 mm)
.875” (22 mm)
1.25” (32 mm)
1.25” (32 mm)
Stem Length:
4.75” (121 mm)
2.75” (70 mm)
4” (102 mm)
4.75” (121 mm)
4.625” (117 mm)
15” (381 mm)
10” (254 mm)
Temperature
Range:
Accuracy:
Resolution:
Power:
Auto Shut-off:
Weight:
(1) 1.5V #LR44
(1) 1.5V #LR44
(1) 1.5V #LR44
(1) 1.5V #LR44
(1) 1.5V #LR44
(1) 1.5V #LR44
(1) 1.5V #LR44
Yes (After 10 min)
Yes (After 10 min)
Yes (After 10 min)
Yes (After 10 min)
No
-
-
.7 oz (20 g)
1 oz (28 g)
1 oz (28 g)
1 oz (28 g)
.5 oz (14 g)
2 oz (56 g) (with clip)
2 oz (56 g) (with clip)
IPX7
IPX7
IPX7
-
-
Water
Resistant
Water
Resistant
Lifetime
Lifetime
Lifetime
1 year
1 year
Lifetime
Lifetime
Water Resistance
Rating:
Regulatory
Listings:
Warranty:
DPS300-01
Digital Pocket Test
with 180° Swivel Head
• On/Off Buttons
• °F/°C Switchable
• Memory Feature
• Reduced Tip Design
DT300
Oval Style Digital
Pocket Test
• On/Off Buttons
• °F/°C Switchable
Adjustable 180O
Swivel Head for
Easy Viewing
From Any Angle
ValCup™
9325
ValCup™
Thermometer Validation Cup
• Quickly validate thermometer accuracy
• Commercial dishwater safe
• BPA-free acrylic
• 6.25” x 4” (159 mm x 102 mm)
• Weight: 6 oz (170 g)
Probe Wipes
9150
Box
• 200 individual foil wrapped
wipes per pack
• 2” x 2” (51 mm x 51 mm)
• Weight: 8 oz (227 g)
Make the perfect ice bath
using the ValCup™
Watch the Video
25
Infrared Thermometers
Temperature Range:
Infrared Accuracy:
Probe Accuracy:
Resolution:
Ambient Operating
Range:
Laser:
412
462
470
480
481
Infrared
-76° to 932°F (-60° to 500°C)
Thermocouple Instrument
-83° to 1999°F (-64° to 1400°C)
-40° to 536°F (-40° to 280°C)
-27° to 428°F (-33° to 220°C)
Infrared
-27° to 428°F (-33° to 220°C)
Thermocouple Probe
-67° to 624°F (-55° to 330°C)
Infrared
-40° to 536°F (-40° to 280°C)
Thermocouple Probe
-40° to 392°F (-40° to 200°C)
±4°F (±2°C)
±2°F (1°C)
±3.6°F (±2°C)
±4°F (±2°C)
±2°F (±1°C)
Thermocouple Jack
±2°F (±1°C)
-
-
Thermocouple Probe
±2°F (±1C°)
RTD Probe
±1°F (0.5°C)
0.1°
1°F above 200°F
0.1°
1°F above 230°F
0.1°
1°F above 200°F
0.1°
1°F above 200°F
0.1°
32° to 122°F (0° to 50°C)
32° to 120°F (0° to 50°C)
32° to 122°F (0° to 50°C)
32° to 122°F (0° to 50°C)
32° to 122°F (0° to 50°C)
Single Dot
Single Dot
-
-
Single Dot
Distance to
Spot (D:S):
12:1
6:1
1:1
1:1
3:1
Emissivity:
0.95 - adjustable from 0.1 to 1.0
0.97 fixed
Preset at 0.95
0.95 - adjustable from 0.1 to 1.0
0.97 Fixed
-4° to 149°F (-20° to 65°C)
-4° to 149°F (-20° to 65°C)
-4° to 149°F (-20° to 65°C)
-4° to 149°F (-20° to 65°C)
-4° to 122°F (-20° to 50°C)
(2) 1.5V AAA
(1) 9V battery Alkaline
(1) Lithium button cell 3V battery
- #CR2032
(1) Lithium button cell 3V battery
- #CR2032
(1) 9V battery
Dimensions:
6.9” x 2.8” x 1.5”
(175 mm x 72 mm x 38 mm)
7.375” x 2.25” x 1.5”
(184 mm x 56 mm x 38 mm)
2.67” x 1.44” x 0.75”
(68 mm x 36 mm x 19 mm)
6.125” x 1.68” x 1.625”
(155 mm x 41 mm x 22 mm)
6.625” x 1.375” x 2.5”
(168 mm x 35 mm x 64 mm)
Battery Life:
180 Hours Typical
140 Hours Minimum
12 Hours
40 Hours Typical
30 Hours Minimum
40 Hours Typical
30 Hours Minimum
100 Hours Typical
6 oz (170 g)
5 oz (142 g)
1 oz (28.4 g)
2.5 oz (73 g)
6 oz (170 g)
1 year
1 year
1 year
1 year
1 year
Storage
Temperature:
Power:
Weight:
Regulatory
Listings:
Warranty:
412
Infrared with Laser Sighting &
Thermocouple Jack
• LCD display with backlight
• FDA Class II, Single-point laser
may be turned on or off
• High/Low alarms
• Measures min, max, average
& differential temperatures
• Accepts all Type K Thermocouple
probes
• Lock-mode for continuous
monitoring up to 60 minutes
• Adjustable emissivity
• Soft carrying case included
470
Mini Infrared Thermometer
The pocket-sized design is
very compact, and includes
lanyard to wear around
your neck.
• Min/Max/Hold/Lock
26
(D:S)
12:1
(D:S)
1:1
462
Slim-Line
Infrared
Thermometer
Easy to use.
Just aim at
the object,
press the button,
and read the
surface
temperature.
• LCD display
with backlight
• Single-point laser
• Auto Shut-off after
7 seconds
480
Dual Temp Infrared
& Probe
For surface and internal
temperature readings.
• Auto Shut-off after
7 seconds/Probe
after 4 mins
(D:S)
6:1
(D:S)
1:1
Infrared Thermometers
422
Gun-style Infrared
with Laser Sighting
422
423
424
425
-76° to 932°F (-60° to 500°C)
-76° to 1157°F (-60° to 625°C)
-76° to 1600°F (-60° to 900°C)
-76° to 1832°F (-60° to 1000°C)
±4°F (±2°C)
±4°F (±2°C)
±4°F (±2°C)
±4°F (±2°C)
0.1°
0.1°
0.1°
0.1°
32° to 122°F (0° to 50°C)
32° to 122°F (0° to 50°C)
32° to 122°F (0° to 50°C)
32° to 122°F (0° to 50°C)
8-point
8-point
Dual Dot
Dual Dot
12:1
16:1
35:1
50:1
0.95 Fixed
Default 0.95 - adjustable from
0.10 to 1.00
Default 0.95 - adjustable from
0.10 to 1.00
Default 0.95 - adjustable from
0.10 to 1.00
-4° to 149°F (-20° to 65°C)
(without battery)
-4° to 149°F (-20° to 65°C)
(without battery)
-4° to 149°F (-20° to 65°C)
(without battery)
-4° to 149°F (-20° to 65°C)
(without battery)
(2) 1.5V AAA (included)
(2) 1.5V AAA (included)
(2) 1.5V AAA (included)
(2) 1.5V AAA (included)
Dimensions:
1.625” x 5.5” x 7.25”
(41 mm x 140 mm x 184 mm)
1.625” x 5.5” x 7.25”
(41 mm x 140 mm x 184 mm)
7.75” x 1.875” x 8”
(197 mm x 48 mm x 203 mm)
7.75” x 1.875” x 8”
(197 mm x 48 mm x 203 mm)
Battery Life:
18 hrs typical/14 hrs
continuous use with laser/
backlight on
18 hrs typical/14 hrs
continuous use with laser/
backlight on
14 hrs typical/10 hrs
continuous use with laser/
backlight on
14 hrs typical/10 hrs
continuous use with laser/
backlight on
8 oz (227 g)
9 oz (229 g)
1 lb (454 g) w/ stand
1 lb (454 g) w/ stand
1 year
1 year
1 year
1 year
Temperature
Range:
Accuracy:
Resolution:
Ambient
Operating Range:
Laser:
Distance to Spot
(D:S):
Emissivity:
(D:S)
12:1
Storage
Temperature:
Power:
Emissivity
Weight:
is a measure of the efficiency in which
a surface emits thermal energy. It is
defined as the fraction of energy being
emitted relative to that emitted by a
thermally black surface (a black body).
A black body is a material that is a
perfect emitter of heat energy and has
an emissivity value of 1.
Regulatory
Listings:
Warranty:
424
Gun-style Infrared
with Laser Sighting
• Measures min, max, average
& differential temperatures
• Programmable HI/LO alarms
• Built-in, high-intensity LED flashlight
• Magnetic stand
• ABS carrying case
423
Gun-style Infrared with
Laser Sighting
Accepts Type K Thermocouple probes
(D:S)
35:1
(D:S)
16:1
e (D)
Distanc
D:S (Distance to Spot Ratio)
The further away from the object,
the larger the surface area measured.
Optical resolution is expressed as a ratio
of the distance to the resolution spot
divided by the diameter of the spot.
0”
6.67”@ 8
3”@ 36”
D:S = 12:1
1” @ 12”
Spot (S)
0.025 m @ 0.3 m
dia.
0.08 m @ 1 m
dia.
0.17 m @ 2 m
dia.
27
Refrigerator/Freezer Thermometers
25HP
330
335
535
2560
-20° to 80°F
(-29° to 27°C)
-40° to 120°F
(-40° to 50°C)
-40° to 80°F
(-40° to 25°C)
-20° to 120°F
(-30° to 50°C)
-22° to 122°F
(-30° to 50°C)
±2°F (±1°C)
±2°F (±1°C)
±2°F (±1°C)
±5°F (±2°C)
±1°F (±0.5°C)
Stainless
Steel
Food Grade
Plastic
Stainless
Steel
Plastic
Food Grade
Plastic
2.375” x 1.5” x 3”
(60 mm x 38 mm x 76 mm)
0.625” x 0.25” x 4”
(16 mm x 6 mm x 102 mm)
4.75” x 0.875” x 1.125”
(120 mm x 22 mm x 29 mm)
2” (50.8 mm)
3.56” x 1.25” x 3.5”
(90 mm x 32 mm x 89 mm)
Glass
Food Grade Plastic
Food Grade
Crystal Clear
Polycarbonate
Plastic
Food Grade
Polycarbonate
1.5 oz (43 g)
.25 oz (7 g )
1 oz (28 g)
.5 oz (14 g)
1.5 oz (43 g)
Temperature
Range:
Accuracy:
Housing Material:
Dimensions:
Lens Material:
Weight:
Regulatory
Listings:
-
Warranty:
1 Year
1 Year
1 Year
1 Year
Lifetime
330
Vertical Glass Tube Thermometer
• Lightweight design
• Durable, plastic casing
• Non-toxic, spirit-filled
glass tube
335
Horizontal Glass Tube Thermometer
• Magnifying lens
• Hangs, stands or permanently mounts
25HP
Refrigerator/Freezer
Thermometer
• Includes dry storage range
• Hangs or stands
2560
Digital Refrigerator/Freezer Thermometer
• Guaranteed Accurate for Life!
• Hangs, stands, or mounts with cable ties
• Large, easy to read display
• Anti-microbial additive
• Removable plastic frame
Hot-Holding Thermometers
24HP
26HP
3210
100° to 600°F
(50° to 300°C)
100° to 175°F
(40° to 80°C)
100° to 600°F
(50° to 300°C)
Accuracy:
±25°F (±12.5°C)
±3°F (±1.5°C)
±25°F (±12°C)
Housing
Material:
Stainless Steel
Stainless Steel
Aluminum
Dial Diameter:
2” (51 mm)
2” (51 mm)
2.5” (64 mm)
Lens Material:
Glass
Glass
Glass
1.5 oz (43 g)
1.5 oz (43 g)
3 oz (85 g)
1 Year
1 Year
1 Year
Temperature
Range:
Weight:
Regulatory
Listings:
Warranty:
28
3210
Grill Surface
Thermometer
• HACCP zoned dial
• Unique side grips
24HP
Oven Thermometer
• HACCP zoned dial
• Hangs or stands
26HP
Hot-holding Cabinet
Thermometer
• HACCP Zoned dial
• Hangs or stands
Digital Wall Thermometers
TRH122M
Temperature
Range:
Accuracy:
14° to 122°F
(-10° to 50°C)
10% to 99% RH
Power:
Weight:
32° to 122°F (0° to 50°C)
25% to 90% RH
T158
IO70
Internal:
32° to 122°F (0° to 50°C)
Internal:
32° to 122°F (0° to 50°C)
External:
-58° to 158°F (-50° to 70°C)
External:
-58° to 158°F (-50° to 70°C)
±2°F (±1°C)
±2°F (±1°C)
+5% RH
±2°F (±1°C)
±2°F
0.1°
0.1°
0.1°
0.1°
1.5” x 0 .5”
(38 mm x 13 mm)
(dual display)
2.875” x 2.125”
(73 mm x 54 mm)
2.875” x 2.125”
(73 mm x 54 mm)
1.625” x 1.375”
(41 mm x 35 mm)
(1) 1.5V Battery AAA
(1) 1.5V Battery AAA
(1) 1.5V Battery AAA
(1) 1.5V Battery AAA
4.5 oz (127 g)
5.5 oz (156 g)
Resolution:
Display - LCD
TRH158
3 oz (85 g)
Regulatory
Listings:
Warranty:
3 oz (85 g)
-
1 Year
1 Year
TRH122M
Mini Temperature/
Humidity Dual-Display
Wall Thermometer
• Min/Max memory and
switchable °F / °C
1 Year
TRH158
Digital Temperature/Humidity Wall Thermometer
• Built-in sensor
• °F/°C selectable
1 Year
IO70
Digital Indoor/Outdoor
Wall Thermometer
• Large LCD
• Built-in sensor
• 10’ cable for remote sensor
T158
Digital Wall Thermometer with Remote Sensor
• Wall or desk mountable
• Remote sensor
• °F/°C selectable
• 10’ cable
Wall Thermometers
Please refer to product specs on page 30
250
5” Wall/Storage
Thermometer
255-14
6” Refrigerator/Freezer
Thermometer
255-06
6” Wall/Storage
Thermometer
29
Wall Thermometers
Wall Thermometers/Hygrometers allow easy monitoring of temperatures. Specialty HACCP color-zoned dial units were developed for use
in critical food-related applications. These thermometers have large numbers and oversized dials for easy viewing.
250/255 Series
212 Series
212-150
212-158
212-159
250
255-06
255-14
268
Temperature Range:
-40° to 120°F
(-40° to 50°C)
0 to 100% RH
10° to 80°F
0 to 100% RH
-10° to 80°F
0 to 100% RH
-40° to 120°F
(-40° to 50°C)
-60° to 120°F
(-50° to 50°C)
-10° to 80°F
-40° to 120°F
(-50° to 50°C)
Accuracy:
±3°F (±1.5°C)
±3°F
±3°F
±2°F (1°C)
±2°F (1°C)
±2°F (1°C)
±2°F (1°C)
Resolution:
2°F increments
1°F increments
2°F increments
±2°F (1°C)
2°F increments
2°F increments
2°F increments
Dial Diameter:
11.5” (291 mm)
11.5” (291 mm)
11.5” (291 mm)
4.5” (114 mm)
6” (152 mm)
6” (152 mm)
-
1 lb (454 g)
1 lb (454 g)
1 lb (454 g)
4 oz (113 g)
3 oz (85 g)
3 oz (85 g)
2 oz (57 g)
1 year
1 year
1 year
1 year
1 year
1 year
1 year
Weight:
Warranty:
212-150
12” Wall Thermometer/Hygrometer
212-158
12” Prep & Dry Storage
Thermometer/Hygrometer (°F)
• HACCP colored-zone dial
30
268
Wall Thermometer
•Non-toxic, spirit-filled glass tube
•Suction cups included for window mounting
• 1-year warranty
212-159
12” Freezer & Cooler
Thermometer/Hygrometer (°F)
• HACCP colored-zone dial
Timers
FT24
TC6
TFS4
TM60
TS100
TW3
0 to 60 Minutes
99 Minutes,
59 seconds
99 Minutes,
59 seconds
Unit Range:
23:59:59 Hours
23:59:59 Hours
99 Hours,
59 Minutes
Resolution:
1 second
1 second
Hours/Minutes
Minutes/Seconds
1 minute
1 second
1 second
Power Source:
(4) 1.5v C
1.5 v AAA
(4) 1.5v C
AC Adaptor (optional)
Wind up
1.5 v LR44
1.5 v AAA
Yes
Yes
Yes
No
Yes
Yes
-
Counts up/down
Counts up/down
-
-
-
Memory / Recall:
Modes:
Alarm Level (Decibel):
90 decibels
85 decibels
90 decibels
70 decibels
70 decibels
70 decibels
Housing:
ABS Plastic
White plastic
ABS plastic
Stainless steel
ABS plastic
ABS plastic
LCD Dimensions:
0.875” x 2.25”
(22 mm x 54 mm)
0.625” x 1.625”
(16 mm x 41 mm)
3” x 3”
(76 mm x 76 mm)
-
0.375” x 0.875”
(10 mm x 22 mm)
1.5” x 2.5”
(76 mm x 64 mm)
Weight:
1 lb 3 oz (539 g)
2 oz (57 g)
1 lb 6oz (523 g)
4.3 oz (122 g)
1 oz (28 g)
3 oz (85 g)
1 Year
1 Year
Regulatory Listings:
Warranty:
2 Years
FT24
Large Single-Station
Digital Timer
• Red light flashes when alarm sounds
• Built-in memory for repeat cycle timing
• Power: (4) 1.5V,
C size batteries included
TS100
Digital Timer/Stopwatch
• 99 minute, 59 second
counter/timer
• Recall feature
• 18” nylon neck cord
• Power: 1.5V, G13A
micro-cell battery included
TM60
Long-Ring 60 Minute Timer
• Non-skid feet for easy,
one-handed operation
• Spring-wound mechanism
• Sturdy, Stainless Steel case
1 Year
1 Year
1 Year
TC6
Digital Timer/Clock/Stopwatch
• Built-in memory
• Splash proof case
• Wire hang, easel stand, clip-on
or magnet-mount
•Power: 1.5V, AAA battery
included
TFS4
Large Multi-Station
Digital Timer
• Switchable: Hours/Minutes
or Minutes/Seconds
• Built-in Memory
• Power: (4) 1.5V, C size
batteries included
• Built-in AC adapter jack
#9374
AC adapter
for TFS4 (optional)
TW3
Large Digit
Multi-Function Timer
• Recall feature
• Water resistant
• Large LCD: 1.5” x 2.5”
(38 mm x 63 mm)
• Power: 1.5V, AAA
battery included
• Wire hang, easel
stand, belt-clip or
magnet-mount
31
Proud Members of:
To request a free copy of any promotional materials contact:
Cooper-Atkins Corporation
33 Reeds Gap Road • Middlefield, CT 06455-0450 U.S.A.
860-347-2256 • Fax: 860-347-5135 • www.cooper-atkins.com
67-1639 • 5M • 1216
Was this manual useful for you? yes no