Important: Read and save these instructions. This guide to be left with equipment. MES2 Installation and Operation Manual Includes installation, operation maintenance and troubleshooting information for the MES2 Electrode Steam humidifier 2554140-B| 24 OCT 2011 Thank you for choosing Nortec. INSTALLATION DATE (MM/DD/YYYY) MODEL # SERIAL # CYLINDER # Proprietary Notice This document and the information disclosed herein are proprietary data of WALTER MEIER LTD. Neither this document nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of WALTER MEIER LTD., except to the extent required for installation or maintenance of recipient’s equipment. All references to the Nortec name should be taken as referring to WALTER MEIER LTD. Liability Notice Nortec does not accept any liability for installations of humidity equipment installed by unqualified personnel or the use of parts/components/equipment that are not authorized or approved by Nortec. Copyright Notice Copyright 2011, WALTER MEIER LTD. All rights reserved. Contents 1 Introduction 2 Receiving and Unpacking 3 MES2 Models 6 Options and Accessories 7 Humidifier Components 9 Humidifier Schematic 9 How the Humidifier Works 11 Installation 12 Typical MES2 Installation 13 Location 14 Mounting 15 Plumbing 16 Steam Lines and Condensate Returns 19 Primary Voltage Wiring 20 Control Wiring 21 Modbus Wiring 22 MES2 Installation Checklist 23 Operation 24 User Interface 25 Humidifier Configuration 27 Modbus Configuration 30 Start Up Procedure 31 Maintenance and Servicing 32 Required Maintenance 36 Extended Shutdown 37 Maintenance Checklist 39 Troubleshooting 41 General Troubleshooting 43 MES2 Faults 45 Wiring Diagram 46 Spare Parts 50 Warranty Introduction CAUTION: Servicing Disconnect main power before performing any servicing. The plumbing and electrical compartments contain high voltage components and wiring. Access should be limited to authorized personnel only. During and following operation of the humidifier, the steam and components in contact with the steam such as the steam lines, steam distributors, cylinders, and condensate lines can become hot and can burn if touched. Walter Meier does not accept any liability for improperly installed humidity equipment or the use of parts/components/equipment that are not authorized or approved by Walter Meier. CAUTION: Electrical All electrical work should in accordance with the local electrical code in location where the humidifier will finally be operated. CAUTION: Plumbing Drain water from humidifier can be very hot. Do not drain to public sink. All plumbing work should be in accordance with local plumbing code in location where the humidifier will finally be operated. CAUTION: Installation Do not mount on hot surfaces Do not mount in area where freezing can occur Do not mount on vibrating surface The MES2 produces steam at atmospheric pressure. No devices which could block steam output should be connected to the steam outlet. Steam lines must be installed so that no restriction can produce backpressure in the humidifier. Regardless of selecting on/off or modulating control method, Nortec humidifiers must have a closed circuit across its on/off security loop control terminal to operate. Nortec highly recommends the use of a duct high limit humidistat and air proving switch. 1 | Introduction Receiving and Unpacking 1 Check packing slip to ensure ALL material has been delivered. 2 All material shortages are to be reported to Nortec within 48 hours from receipt of goods. Nortec assumes no responsibility for any material shortages beyond this period. 3 Inspect shipping boxes for damage and note damages on shipping waybill accordingly. 4 After unpacking, inspect equipment for damage and if damage is found, notify the shipper promptly. 5 All Nortec products are shipped on an FOB factory basis. Any and all damage, breakage or loss claims are to be made directly to the shipping company. Before Installation 1 Ensure that available voltage and phase corresponds with humidifier voltage and phase as indicated on humidifier’s specification label. 2 Ensure that the dedicated fused disconnect provided for the humidifier is of sufficient size to handle the rated amps as indicated on the specification label. 3 Ensure sufficient clearances will be available as described in “Location” on page 13. 4 Ensure steam lines can be routed to distributor as described in Steam Lines and Condensate Returns on page 16. Figure 1: Specification Label Location Introduction | 2 MES2 Models The MES2 is the most advanced OEM steam humidifier available and provides steady and reliable humidification using the same proven cylinder technology as Nortec’s commercial NHTC. The MES2 is offered in 5 models corresponding to control configurations as shown in Figure 2. The remote configurations include 8 ft (2.4 m) of wiring for connecting the controls to the plumbing cabinet. The Primary Voltage Wiring (PVW) model provides 8 feet of primary wiring for connection to the contactor. Remote Attached PVW Open Electrical Attached N/A (REM OE) Closed Electrical (ATT OE) (ATT CE) (REM CE) (ATT CE PVW) Figure 2: MES2 Models The MES2 is available in 6 capacities ranging from 5 to 30 lb/hr (2.3 to 13.6 kg/hr) for operation on a range of voltages and phases as outlined in Table 1: MES2 Part Numbers and Electrical Data. The 6 capacities are packaged in 4 different cabinet sizes as shown in Figure 3. 5 lb/hr (2.3 kg/hr) 10 lb/hr (4.5 kg/hr) 15 - 20 lb/hr (6.8 - 9.1 kg/hr) Figure 3: MES2 Capacities and Cabinets 3 | Introduction 25 - 30 lb/hr (11.4 - 13.6 kg/hr) Table 1: MES2 Part Numbers and Electrical Data Capacity lb (kg) 5 (2.3) 10 15 (4.5) (6.8) Phase 1 1 1 3 20 (9.1) 1 3 25 30 (11.4) (13.6) 3 3 Attached Open Elec. Attached Closed Elec. Remote Open Elec. Remote ATT OE ATT CE REM OE REM CE ATT CE PVW No. V A A KW 2550262 3E+06 2550264 2550265 2550266 102 3E+06 3E+06 2550269 2550274 2550270 2550275 2550271 2550276 103 104 2550277 3E+06 2550279 2550280 2550281 202 2550282 2550287 3E+06 3E+06 2550284 2550289 2550285 2550290 2550286 2550291 203 204 2550300 3E+06 2550302 2550303 2550304 321 2550305 2550310 3E+06 3E+06 2550307 2550312 2550308 2550313 2550309 2550314 305 309 2550315 3E+06 2550317 2550318 2550319 303 2550320 2550325 3E+06 3E+06 2550322 2550327 2550323 2550328 2550324 2550329 311 311 2550340 3E+06 2550342 2550343 2550344 321 2550345 2550350 3E+06 3E+06 2550347 2550352 2550348 2550353 2550349 2550354 305 309 2550355 3E+06 2550357 2550358 2550359 303 2550360 2550365 3E+06 3E+06 2550362 2550367 2550363 2550368 2550364 2550369 311 311 2553765 3E+06 2553767 2553768 2553769 421 2553770 2553775 3E+06 3E+06 2553772 2553777 2553773 2553778 2553774 2553779 407 411 2550370 3E+06 2550372 2550373 2550374 421 2550375 2550380 3E+06 3E+06 2550377 2550382 2550378 2550383 2550379 2550384 407 411 8.2 7.1 6.1 4.5 3.5 2.8 16 14 12 8.9 7.1 5.7 25 21 18 13 11 8.5 14 12 7.7 6.1 4.9 33 28 25 18 14 11 19 16 10 8.2 6.5 24 20 13 10 8.2 28 25 16 12 9.8 15 15 15 15 15 15 25 20 20 15 15 15 40 30 30 20 15 15 20 20 15 15 15 50 45 35 30 25 20 30 25 15 15 15 35 30 20 15 15 40 40 25 20 15 1.7 2550267 2550272 208 240 277 380 480 600 208 240 277 380 480 600 208 240 277 380 480 600 208 240 380 480 600 208 240 277 380 480 600 208 240 380 480 600 208 240 380 480 600 208 240 380 480 600 Closed Elec. Attached Closed Elec. PVW Standard Cylinder Volts Amps Max Ext Fuse KW 3.4 5.1 6.8 8.5 10 Introduction | 4 MES2 Dimensions / Weights 2.30 5.8 A D F E 5.50 14 0.34 (9 mm) Condensate Return 0.57 1.4 B 1.28 3.3 0.875 (22 mm) O Steam Outlet 0.30 0.8 7.79 19.8 C 1/8 NPT Fill Connection G 0.80 2 3.70 9.4 1.73 4.4 1.12 x 2.0 (2.85 x 5.1) Slot Both Cabinet Sides 2.5 (6.4) MES2 25 - 30 1.5 (3.8) MES 5 - 20 H 0.875 (22 mm) O Drain Outlet J O 5.45 13.8 Rotate 360v to Desired Position Note: Unless otherwise specified dimensions are in inches (cm). Tolerance ±0.1 in. (0.25 cm) Capacity A B C Height D* Steam Outlet E* Steam Outlet F Elec. Pos. G Elec. Height H Drain Center J Drain Center Net/Full Weight** lb (kg) lb/hr (kg/hr) Width Depth 5 (2.3) 10 (4.5) 15-20 (6.8 – 9.1) 25-30 (11.4 – 13.6) 7.5 (19) 7.5 (19) 8.9 (22.6) 10.3 (26.2) 6.4 (16.3) 6.4 (16.3) 7.9 (20.1) 9.8 (24.9) 12.7 (35.3) 16.8 (42.7) 20.0 (50.8) 20.7 (52.6) 4.2 (10.7) 4.2 (10.7) 5.1 (13) 5.5 (14) 5.1 (13) 5.1 (13) 4.0 (10.2) 4.9 (12.5) 0.3 (0.8) 0.3 (0.8) 1.1 (2.8) 2.2 (5.6) 4.9 (12.5) 8.0 (20) 11.2 (28.5) 11.6 (29.5) 5.6 (14.2) 5.6 (14.2) 6.4 (16.3) 6.8 (17.3) 3.4 (8.6) 3.4 (8.6) 4.2 (10.7) 5.2 (13.2) 10.7/14.2 (5/6.6) 12.4/18.4 (5.8/8.5) 16.5/30.5 (7.8/14.2) 20.2/43.2 (9.5/20.0) Note: * Steam Outlet is not centered on MES2 5 & 10 lb/hr (2.3 & 4.5 kg/hr) models. ** Weights given for MES2 with enclosed electronics and optional plumbing enclosure. Full Weight is weight with cylinder full of water. Full weight may exceed this value at end of cylinder life depending on the amount of scale and its composition. Figure 4: MES2 Dimensions and Weights 5 | Introduction Options and Accessories An enclosed plumbing option is available for each MES2 cabinet size. The option consists of a fixed cabinet with an easily removable door for servicing. Figure 5 shows the enclosed plumbing option installed on a 10 lb/hr MES2 ATT CE. Enclosed Plumbing Part Numbers Capacity Part No. 5 lb/hr (2.3 kg/hr) 2554073 10 lb/hr (4.5 kg/hr) 2554074 15, 20 lb/hr (6.8, 9.1 kg/hr) 2554075 25, 30 lb/hr (11.4, 13.6 kg/hr) 2554076 Figure 5: Enclosed Plumbing Option Nortec also provides a complete line of options and accessories for every humidification application. The following table lists some of the most common accessories available for use with the MES2 humidifier. Refer to the installation instructions that come with the accessories for their proper installation and operation. Table 2: Options and Accessories Option / Accessory Used For Modbus Interface Controlling humidifier operation via Modbus (See Modbus Wiring on page 21 and Modbus Configuration on page 27). Enclosed Plumbing See above. Steam Distributors Adding steam into air ducts. On/Off or Modulating Control Humidistats Controlling the output of the humidifier based on sensed RH. Air Proving Switch Insuring humidification only occurs when air is moving in a duct. Steam Hose Connecting humidifier to steam distributor. Condensate Hose Collecting and draining condensate that collects in steam distributors and steam distribution lines. Introduction | 6 Humidifier Components Ground Clamp Control Board Power Relay Capacity Adjustment Potentiometer Electrical Cover Current Sensor On/Off/Drain Switch Status Lights Bracket, Remote Electrical Control Connection Terminals Condensate Return Steam Outlet High Water Sensor Plug Plumbing Enclosure (Optional) Fill Cup Cylinder Plug Cylinder Cylinder Tie Wrap Fill Inlet Drain Pan Fill Valve Drain Valve Drain Outlet Drain Canal Figure 6: MES2 Components 7 | Introduction Plumbing Door (Optional) Table 3: MES2 Components Component Function of Component Bracket, Remote Electrical Supports the control components for MES2 models which have remote electronics (REM). Capacity Adjustment Potentiometer Adjusts the maximum output of the humidifier from 100% down to 20%. See Figure 22: Capacity Potentiometer Adjustment on page 26. Condensate Return Provides a connection to return condensate to humidifier. Control Connection Terminals Terminals on the control board for connecting external controls to humidifier. Current Sensor Measures the amount of current flowing through the cylinder’s electrodes. Cylinder Holds electrodes in water. Current between electrodes generates heat used to generate steam. Cylinder Plug Power connectors to electrodes in cylinder. Installer must connect wires from contactor to cylinder plugs. (PVW model has wires installed). Cylinder Tie Wrap Holds cylinder in place, reusable. Drain Outlet / Canal Combines cylinder drain water and fill cup overflow into a single drain outlet. Drain Pan Collects any water which may leak from water connections and routes it to drain. Drain Valve Drains water from humidifier. Control Board Controls all functions of the humidifier’s operation and provides input and output connections to humidifier components. Electrical Cover Covers the control board and wiring on MES2 models with closed electrical (CE). Fill Cup Provides an air gap for backflow prevention. Fill Inlet 1/8 NPT brass fitting for connecting supply water to the humidifier. Fill Valve Controls flow of water into humidifier. Ground Clamp Electrical ground connection for humidifier. High Water sensor Plug Used to detect max water level in cylinder. On/Off/Drain Switch Turns power on/off to humidifier controller and drains the cylinder for servicing. Note: Turn off humidifier disconnect to shut off primary power to the humidifier. Plumbing Enclosure/ Door The optional plumbing enclosure completely encloses the humidifiers water components. Power Relay Turns on/off power to the contactor (supplied by others) based on a signal from the humidifier’s controller (mounted on control board). Status Lights Indicate if the humidifier is operating. If the humidifier is shut down on a fault the yellow LED flashes in sequence to indicate the fault that occurred. Steam Outlet Outlet for steam generated by the humidifier. Connect to the outlet with a steam hose and hose clamp. Introduction | 8 Humidifier Schematic Air Gap 1.25 in. (3.2 cm) Steam Line Steam Distributor Condensate Return Fill Cup Control Board Current Sensor Cylinder Power Relay Overflow 24 VAC High Water Sensor Electrodes To From Contactor Contactor Fill Valve Drain Valve Internal Air Gap External Air Gap Drain Canal Figure 7: Humidifier Schematic How the Humidifier Works The MES2 is an atmospheric steam generator that uses heat generated by electrical current flowing between submerged electrodes to generate steam. The MES2 is designed for air humidification via steam distributor. Steam Generation If the MES2 is configured for On/Off operation then as soon as the safety loop between terminal 1 and 2 is closed the humidifier assumes 100% demand, closes the power relay on the control board, and measures the current flowing through the power wire routed through the control board’s current sensor. If it is configured for modulating operation it waits for a demand signal and for the safety loop between terminal 1 and 2 to be closed. 9 | Introduction If the demand is lower than the actual output the inlet valve is kept closed and output is reduced by letting the water level in the cylinder decrease by evaporation. If demand is higher than the actual output after a brief delay the fill valve is activated and water flows into the fill cup. Water from the fill cup flows into the bottom of the cylinder through a hose connected to the drain valve housing. Note: The cylinder is gravity fed from the fill cup. If backpressure from the steam line is too high it will cause water to back up in the fill cup and flow down the overflow line to the drain. A soon as the water in the cylinder comes in contact with the energized electrodes current flows through the water. The resistance of the water to the electrical current generates heat and in turn steam. The more electrode that is covered by water the higher is the current and output. The unit continues to fill until the current matches demand or the high water sensor detects a high water level. The MES2 repeats the fill and boil down cycle repeatedly to match output to demand. Over time minerals in the water will adhere to the cylinder’s electrodes. The humidifier will automatically fill to a higher water level to maintain full capacity during the life of the cylinder. Eventually because of scale formation it will no longer be possible for the humidifier to reach its full capacity. The MES2 software monitors this condition and when detected will stop operating and flash the yellow LED in a repeating sequence of 4 flashes. Drains As steam is produced minerals are left behind increasing the conductivity of the water. The MES2’s patented auto adaptive cycle will monitor the water conductivity and perform drains to maintain the water at optimal conductivity for peak performance. The auto adaptive cycle provides the longest cylinder life in combination with keeping the tightest control and most efficient use of water during the entire cylinder life. Steam Distribution The most common method for adding the steam into the air is to mount a steam distributor in a supply air duct as shown in Figure 7: Humidifier Schematic. In an air handler the best location for introducing the steam is after the heating coil where the air will be at its lowest humidity. Steam Line The steam line between the cylinder steam outlet and the distributor may be Nortec steam hose, copper pipe, or stainless steel pipe or tube. The MES2 is an atmospheric steam generator so it is very important no restrictions are present in the steam line and that the steam line is sized properly to carry the full output capacity of the humidifier. See Steam Lines and Condensate Returns on page 16 for information on selecting steam lines. Condensate Return Whenever steam is generated, condensate is formed in the distribution system and steam distributor. Insulating steam lines is one important way to reduce the amount of condensate formed. Steam lines are sloped so that condensate does not collect in the lines and create a restriction to steam flow. The condensate must be collected and removed from the system so that it does not build up and leak into the duct or air handler. Condensate can be returned to the MES2 fill cup to reduce water waste or can be fed to drain. Introduction | 10 Installation 12 13 14 15 16 19 20 21 22 11 | Installation Typical MES2 Installation Location Mounting Plumbing Steam Lines and Condensate Returns Primary Voltage Wiring Control Wiring Modbus Wiring MES2 Installation Checklist Typical MES2 Installation Power Relay On/Off Drain Switch Control Wiring Pg 20 Fuse 1 ft (30 cm) 2 in. (5 cm) 12 in. (30 cm) min. min. radius* Steam Distribution Page 16-18 Support brackets* 1 ft (30 cm) min. before any bend* Condensate trap E n e rg iz e C o n ta c to r 2 4 V A C L o o p ) (S a fe ty O n /O ff 2 4 V A C Steam Line Front side r clearance required for cylinder removal. Location Mounting Pg 13 36 in. (90 cm) recommended Drain Line Fill Line Plumbing Pg 15 0.875 in. (22 mm). OD 1/8 in. NPT Note: Single Phase Connection Shown Cylinder plug with white marker Air gap recommended Drain 7/8 in. Min. Cold Potable Water 30 - 80 PSIG L2 L1 Disconnect Contactor Current transformer Primary Voltage Pg 19 * Dimensions and brackets are recommendations based on best practice. OEM must verify operation if they are not followed or used. Figure 8: Typical Humidifier Installation Installation | 12 Location Mount to structural member or on surface capable of supporting the humidifier’s operating weight (see Figure 4: MES2 Dimensions and Weights). The humidifier may be set on its base but clearance must be provided for the drain line to be sloped adequately. In general clearance is not required around the humidifier except for maintenance access and electrical and plumbing connections. The clearance dimensions shown are recommendations based on best practice. OEM must verify operation if they are not followed. Install only in areas with ambient temperature 41-104°F (5–40°C) relative humidity 5 95%. When possible install below the steam distributor. If mounted above the steam distributor take care to provide proper steam line routing and proper condensate traps. DO NOT locate the humidifier any further then absolutely necessary from the steam distributor location as net output will be reduced as a result of heat loss through the steam line. The main service access required is for changing the cylinder. This access can be from the front or right side. Right side service access is not possible with the optional plumbing enclosure. Note: Nortec recommends a vertical drop from the drain outlet and an air gap as close as possible to the drain outlet to insure proper draining of the humidifier. 0.5 in. (1.3 cm)* top clearance access hole required for steam outlet and optional condensate return to fill cup. 8 in. (20 cm)* left side clearance for removal of cover on attached closed electronics models only. 0 in. (0 cm) access hole or additional clearance required for fill connection As close as possible to steam distributor 5-95% 0.2 (0.5 cm)* for fill cup tabs. Mount level 0 in. (0 cm) side clearance for front cylinder removal 36 in. (92 cm)* front clearance for front cylinder removal and/or for attached electronics models only. 36 in. (92 cm)* side clearance for right side cylinder removal only. 0 in. (0 cm) front clearance for right side cylinder removal Note: side cylinder removal not possible with enclosed pluming option. 0 in (0 cm) bottom clearance. Access for properly sloped drain required. * Dimensions are recommendations based on best practice. OEM must verify operation if they are not followed. Figure 9: Mounting Location / Clearance 13 | Installation Mounting 1 The MES2 humidifier can be wall or floor mounted. No mounting holes are provided but can be made anywhere in the base and sides of the cabinet at installation time. 2 Use a minimum of 2 x #8 screws mounted securely into structural surfaces. 3 Make sure the unit is level. 4 If enclosed plumbing option is installed then mounting screws can also be installed into the plumbing enclosure. 5 It is the installer’s responsibility to insure that the humidifier is securely and safely mounted in the air handler. Note: Installation methods shown are suggestions only actual mounting may differ and must be verified by OEM. When mounting to a vertical member by drilling holes in the cabinet, be careful not to make any holes in the bottom 1 in (2.5 cm) of the drain pan. MES2 Attached Electronics (Back Mounted) MES2 Remote Electronics (Side/Base Mounted) Air Handler Remote Electronics Mount using 4 screws i 0.19 in. mounting holes Plumbing Drill holes in back, side, or base of cabinet and secure with min. of 2 x #8 Screws. Avoid drilling in bottom 1 in (2.5 cm) of drain pan. Figure 10: MES2 Mounting Installation | 14 Plumbing 0.875 in. (22 mm). OD un-threaded outlet 1/8 in. NPT fill connection. Air gap recommended. 1 1/2 in. to 7/8 in. Copper reducer is ideal. (Nortec option P/N 2522172) Hose must not touch the bottom of the funnel. Always install a water shut-off valve. Use 1/2 in. OD copper to within 4 ft (1.2 m) of humidifier Min. 7/8 in. OD drain line. Ensure adequate slope to handle flow. *Elbows, pipe, water shut-off valve, and air gap reducer not supplied by Nortec. Figure 11: Water Supply and Drain Connection All water supply and drain line connections should be installed in accordance with local plumbing codes. Supply water is recommended at 30 to 80 PSIG and 150-1200 Microsiemens (Hardness 012 GPG). Consult factory for water conditions outside of this range. Install water shut off valve before humidifier to facilitate servicing. The drain line should not end in a sink used frequently by personnel, or where plumbing codes prohibit it. Route to a floor drain or equivalent for safety reasons. Ensure drain line is adequately sized to provide free and easy draining and that an air gap is installed as shown. A restricted drain can cause cylinder water to over concentrate and result in poor operation. If a drain is not located near the humidifier use a condensate pump rated for hot drain water such as Nortec’s P/N 1429527. For humidifiers installed in some cities including the City of Los Angeles: A city-approved spring-loaded double ball CHECK VALVE must be installed by contractor on the potable water inlet to the humidifier. Recommended valve manufacturer: Watts Regulator, Size 3/8” inlet and outlet, Model #7. Each drain line from the humidifier must be routed, without dips or sags, to terminate above the flood level rim of a city approved indirect waste receptor. 15 | Installation Steam Lines and Condensate Returns MAIN RULES FOR ATMOSPHERIC STEAM LINES Slope the steam lines Trap condensate (Use full size ‘T’ for Traps) Condensate traps must be a minimum of 3 in. (15 cm) in height or duct static pressure + 2 in. whichever is greater. Steam lines must not have any restrictions which could cause back pressure. 1.0 in. (2.5 cm) pipe insulation recommended. Follow recommended materials, size and length see tables. Use Appropriate Slope 10 Degrees Direc Steam tion 2 in. (5 cm) 1 ft (30 cm) 2 Degrees Steam Dire Ste am D irecction tion 0.5 in. (12 mm) Insulate Pipe 1 in. (2.5 cm) pipe insulation 1ft (30 cm) Figure 12: Main Steam Line Requirements Table 4: Recommended Steam Line Material Steam Line Material Steam Line Length ft m Steam Line Description Copper Tube 0-10 0-3 3/4 in MED-L Tubing (7/8 in. OD) Stainless Steel Tube 0-10 0-3 7/8 in. Tubing (0.049 W) Nortec Hose < 10 <3 Part Number 1328810 (7/8”) Note: Larger diameter lines should be used for steam runs longer than those listed. Contact Nortec for recommendation and instructions on proper installation of reducers for larger diameter steam lines. Table 5: Maximum Recommended Length of Steam Line Steam Output (Lb/hr) Distance (ft) Possible Loss (lb/hr) Steam Line Size (in) 5 10 15 20 25 30 8 15 1.0 1.5 3/4 3/41 20 2.0 3/41 25 2.5 3/41 NOTE: 1 Contact Nortec for information on possible losses of other steam line diameters used for longer runs. 2 The use of steam line other then copper, stainless steel tube or Nortec supplied steam line will void the warranty and may adversely affect the operation of the humidifier Installation | 16 Tee is same size as steam line Use a full size tee, not a 90 degree elbow for vertical to horizontal transitions. 12 in. (30 cm) min drop to top of ‘P’ Trap ‘P’ Traps Use: - NORTEC 0.375 in condensate hose - 1/4 in Med-L copper tubing, or - 0.375 in stainless steel tubing P Trap min 6 in. (15 cm) or duct static pressure + 2 in whichever is greater Condensate drains must be sloped down. Route to humidifier fill cup if possible. Figure 13: Condensate Traps 1 ft (30 cm) 12 in.(30 cm) min. radius* 2 in. (5 cm) min. Condensate line Support brackets* 1 ft (30 cm) before any bend* Connect condensate hose to fill cup or to drain. Condensate trap Connect steam hose to cylinder * Dimensions and brackets are recommendations based on best practice. OEM must verify operation if they are not followed. Figure 14: Steam Distributor Above Humidifier (Hose) 17 | Installation Support brackets* 12 in. (30 cm) min. radius* Hose will soften over time proper support Is necessary 1ft (30 cm) min. before any bend* Obstruction 2 in. (5 cm) 1 ft (30 cm) min. Use full size condensate tee at low point. Slope lines up to “T” and immediately after it. 1 ft (30 cm) min. (recommended) To drain To drain * Dimensions and brackets are recommendations based on best practice. OEM must verify operation if they are not followed. Figure 15: Steam Distributor Below Humidifier With Obstruction (Hose) No drop to condensate trap No condensate trap at vertical transition Steam line not sloped Figure 16: Common Steam Line Errors Installation | 18 Primary Voltage Wiring Cylinder Plugs Ground Lug (on cabinet ATT or on bracket REM) Remote Electrical Bracket ground wire Cabinet ground wire Secure wires with tie wraps to tabs provided in mounting bracket Note: 1 Ensure mains voltage and HWS jumper settings match operating voltage (see table below for setting, see Figure 21 for jumper location). 2 Dedicated fused disconnect 3 Phase must be installed. Fusing must not exceed max circuit protection as indicated on the specification label. 3 Ensure that adequate power is available to carry full humidifier amp draw as indicated on the specification label. 4 Insert wires into cylinder plugs and tighten with 2mm allen wrench L3 to11 in-lb. L2 L1 5 Ensure both plumbing cabinet and remote electrical bracket Disconnect (if present) are grounded. Use ground wires if required. 6 All wiring to be in accordance with national and local 1 Phase electrical codes. Cylinder plug with white marker Contactor Current transformer Cylinder plug with white marker Mains Voltage and HWS Select Mains Voltage Jumper HWS Jumper 600 J1 J8 J2 480 J3 380 J4 277 J5 J9 240 J6 208 L2 L1 Disconnect Contactor Current transformer Figure 17: Primary Power Connection 19 | Installation Control Wiring Contactor Contactor Ground 24 VAC On/Off Safety Loop Tie wrap wires to tabs provided Control Signal Mandatory Wiring: Use min. 18 AWG and keep as short as possible. 1 24 VAC to fuse connected to On/Off/Drain switch and to power relay 0.25 in. spade connectors. , 2 Ground wire from humidifier ground to air handler ground. 3 On/Off/Safety input (24 VAC) input to point 2 of P3. Optional Wiring: 4 Modulating control input (0-10 or 2-10 VDC)to P5 (J10 must be removed for modulation). 5 500 ohm resistor between 1-2 of P5 for mA modulating control input. 6 Remote Fault to P2. Cut-out in cover for wiring Electrical Cover (Enclosed electrical models only) Power Relay On/Off Drain Switch Fuse Contactor Fault P2 Remote (NO) P3 On/Off (Safety Loop) 24VAC (+) P5 Control Signal (-) Fuse+Power Relay 24 VAC Figure 18: Control Wiring Installation | 20 The MES2 humidifier can be operated with either On/Off controls or On/Off Safety and one modulating input. See On/Off or Modulating Control (J10) on page 26 to configure the MES2 for modulation. For control wiring use minimum 18 AWG and keep as short as possible. For Modbus wiring use 18-24 AWG shielded, twisted pair 120 Ω impedance cable. Remote fault indication is provided via a normally open relay which is closed when the controller is in a fault condition. The dry contact may be connected to maximum of 1 amp at 24 VAC or 24 VDC. Note: Regardless of selecting on/off or modulating control method, Nortec humidifiers must have a closed circuit across its on/off security loop control terminal to operate. Nortec highly recommends the use of a high limit humidistat and an air proving switch in series for this function. Modbus Wiring The optional Modbus interface board can be installed onto the MES2 control board to provide Modbus control of the MES2. In order for Modbus control to be active a jumper must be installed on J26 of the control board. See Modbus Configuration on page 27 for information on configuring Modbus communication. Note: 1 Requires optional Modbus board (PN 1509592) 2 Use 18-24 AWG shielded, twisted pair 120 Ω impedance cable. 3 Connect shield at one end only. 4 J26 must be installed for Modbus control. Modbus Board (Optional) Modbus RS485 Connection A B Common Figure 19: Modbus Wiring 21 | Installation MES2 Installation Checklist Unit Serial #: _________________ No. of humidifiers: _______ Unit type: _______ __________ Voltage: ________V/_____ph Cylinder type: Customer/Job: Tag: _______________ Address: WATER QUALITY: Well water City water POWER: Voltage, amp, fuse per Spec Label: Jumper 1-6 setting _________________ Jumper 8/9 settting ________________ Disconnect switch yes no yes no HUMIDIFIER MOUNTING: (Clearances around the unit Acceptable Obstruction) Humidifier level. Cylinder removal clearance STEAM LINE(S): Material Slope up (min 2 in/ft). Low point condensate traps Type of Insulation if installed Diameter / Size Slope down (min 0.5 in/ft) No hose kinks / Restrictions CONDENSATE LINE(S): P Trap min 6 in or duct press + 2 in P Trap sufficient drop to ensure flow WATER LINE: 1/2 in to within 4ft of unit Water pressure: 30-80 psig DRAIN LINE: Diameter / Size ______________ Air gap within 3 ft of the unit CYLINDER: Seated in drain valve and secured yes no WIRING: Wiring connections and connectors secured yes no CONTROLS: On / Off / Security loop devices working correctly Jumper J10 set to Modulating (removed) Or On/Off (installed) Jumper J26 set to Terminal block input control (removed) Or Modbus control (installed) Inspected by: yes no Date of inspection: ______/_______/______ Company: Installation | 22 Operation 24 User Interface 24 LED Status Lights 24 On/Off Drain Switch 25 Humidifier Configuration 26 Capacity Adjustment 26 Mains Voltage Select (J1 to J6) 26 High Water Sensor Voltage (J8 and J9) 26 On/Off or Modulating Control (J10) 26 Modulation Offset (J13) 27 Ground Fault Interrupt (GFI) (J15) 27 Modbus Control (J26) 27 Modbus Configuration 27 Modbus Addresses 30 Start Up Procedure 23 | Operation User Interface LED Status Lights The MES2 user interface includes 2 LED’s which provide information about the humidifier’s current status. Green LED On Indicates steam is being produced Green LED Blinking Indicates humidifier is on but there is no requirement for humidity. On/Off/Drain Switch (Turns humidifier On/Off and drains the cylinder) Yellow LED On Indicates that water level is high Yellow LED Flashing (LED will flash fixed number of times then pause.) Indicates the controller has detected a fault and has shut down. Number of flashes indicates which fault. See Troubleshooting for more information. Figure 20: User Interface Yellow LED Steady On When the yellow LED is steady on (not flashing) it indicates that the high water sensor has interrupted filling of the cylinder. The LED is on for information only and unless it persists for an extended period of time it does not require any action. On/Off Drain Switch The On/Off Drain switch turns on power to the MES2 control board or to the MES2’s drain valve. For normal operation the switch should be set to the On position. To manually drain the humidifier set the switch to the drain position until the cylinder is completely empty then turn the switch off. Do not leave the switch in the drain position for extended periods of time. When servicing the humidifier the switch should be set to Off and the fused disconnect or breaker should be turned to Off. Operation | 24 Humidifier Configuration The MES2 is factory configured to operate under most conditions without the need for any changes to its configuration. If required several settings can be made using jumpers on the MES2’s control board. The output of the MES2 can also be reduced by using a potentiometer on the MES2’s control board. See Figure 21: MES2 Control Board Jumpers for location of jumpers and the capacity adjustment potentiometer. Note: Nortec recommends not making any configuration changes unless they are required and that any changes to the MES2’s settings be performed by a qualified technician. J8 & J9 HWS Voltage Potentiometer Capacity Adjustment P11 P11 (2-3) Disable Self Test J1 - J6 Mains Voltage Select J26 Modbus Control J13 & J15 Modulation Offset & GFI J10 On/Off or Modulating Figure 21: MES2 Control Board Jumpers Table 6: MES2 Control Board Jumpers Jumper Installed Removed J1 J2 J3 J4 J5 J6 J8 J9 J10 J13 J15 J26 P11 (2-3) 550-600 V 440-480 V 380-415 V 277V 220-240 V 200-208 V HWS setting for 380-600 V HWS setting for 200-277 V On/Off Operation 2-10 VDC or 4-20 mA* modulation GFI on, power relay off during drain Modbus control enabled Self test at start up disabled No Affect No Affect No Affect No Affect No Affect No Affect No Affect No Affect Modulating Operation 0-10 VDC or 0-20 mA* modulation GFI off power relay on during drain Modbus Control disabled Self test at start up enabled * mA modulation control requires a 500 ohm resistor installed between pins 1-2 of P5 control signal input terminal (see Figure 18: Control Wiring. 25 | Operation Caution: Never adjust jumpers other than those listed in this section. Other jumpers are factory set and must not be changed. Capacity Adjustment The Capacity adjustment potentiometer can adjust the capacity of the humidifier between 100% and 20% of its rated output. (Factory setting = 100% output) 20% 100% Figure 22: Capacity Potentiometer Adjustment Mains Voltage Select (J1 to J6) The jumper setting must be set to match the operating voltage of the humidifier. The MES2 is factory calibrated to provide maximum output over a range of operating voltages depending on the setting of J1 to J6. Changing the jumper location sets the fill off amps of the humidifier to correspond to that required at its operating voltage. One jumper only must be installed on J1 to J6. See Table 6 for correct jumper placement. High Water Sensor Voltage (J8 and J9) The MES2 detects high water by measuring current flowing to its high water sensor pin (Cylinder plug with white marker). To insure accurate detection of current, the High Water Sensor (HWS) circuit must be configured using J8 and J9 to match the operating voltage. A jumper must be installed on either J8 or J9, not on both. See Table 6 for correct jumper placement. On/Off or Modulating Control (J10) The MES2’s output can be controlled by either an On/Off humidistat or a modulating humidistat. To set the MES2 to operate with a modulating humidistat remove Jumper J10. (Factory setting = jumper Installed, On/Off operation) J10 Removed– Modulating operation, the controller monitors the demand signal on terminal point 4 of the control terminal strip and adjusts humidifier output to match it. For mA control install a 500 ohm resistor across pins 1 and 2 of P5 control signal input terminal. J10 Installed - The MES2 is configured for On/Off operation. The controller will ignore any modulating signals even if they are connected. Modulation Offset (J13) The MES2 controller can be configured to work with a modulating humidistat with 4-20 mA or 210 VDC output. Modulation offset can be configured with jumper 13. (Factory setting = Jumper Removed, 0-10 VDC or 0-20 mA control signal). See Table 6 for correct jumper placement. Operation | 26 Ground Fault Interrupt (GFI) (J15) Ground current leakage can occur when the humidifier performs drains. With jumper J15 the MES2 can be configured to turn off the power to the electrodes whenever a drain takes place. See Table 6 for correct jumper placement. Modbus Control (J26) The MES2 can be controlled via its Modbus interface. When configured for Modbus control the MES2 ignores On/Off and modulation control inputs on its control terminal strip and operates strictly based on data received via Modbus. The Modbus interface can also be used to make some configuration changes and to read the status of the MES2. See Table 7. J26 Removed – The Modbus interface is turned off and the humidifier operates based on control inputs at its terminal strip. J26 Installed – The Modbus interface is turned on. The humidifier will operate strictly based on control inputs received via Modbus and can be configured and queried using the Modbus interface. Disable Self Test (P11, 2-3) On start up the MES2 performs a self test that activates all outputs briefly including the remote fault output. To disable the self test the jumper installed on P11 pins 2-3 can be installed. Modbus Configuration Contact Factory – 1-866-NORTEC-1. Modbus Addresses The following table lists the MES2 parameters that are available via Modbus. 4XXXX parameters can be read and written by the Modbus master. 3XXXX parameters are read only. Table 7: Modbus Addresses Function Description Address Details Output Control OFF Disables the humidifier and places the humidifier in standby mode ON Enables the humidifier (humidifier will operate based on the SET OUTPUT input) 40002 255: inhibit actions of humidifier 0: allow normal operation Set Output Sets the desired steam output from 0100% This value shall be zero after a microprocessor reset 40004 Remotely set humidity reading over network. Value of 0 to 100 (per cent). If no network signal for N minutes, reverts to 0. 27 | Operation Table 7: Modbus Addresses (Continued) Function Description Address Details Force Drain When written to (FF), will interrupt the humidification process and activate the humidifier drain valve. After 20 minutes the controller will reset this value (00). After a microprocessor reset, the default setting shall be (00) 40005 255 will start the process, 0 will be accepted, to clear if the request has not been cleared itself Reset Run Hour Counter Resets the humidifier controller’s run hour counter to zero hours 40006 255 will start the run hours counter process. 0 will be accepted to clear the run hours counter. Set Modbus address Change the humidifier controller’s MODBUS address. Range is 1-247. This setting shall be non-volatile with a default setting of 1. 40201 The value changes will only take effect following a hardware reset of the control board. Set Modbus Baud rate Changes the humidifier’s baud rate. Range is 4800, 9600, and 19200 B/sec. This setting shall be non-volatile with a default value of 9600 B/sec. 40202 The value changes will only take effect following a hardware reset of the control board Set Modbus parity Change the humidifier controller’s MODBUS parity. Range is None, Even, Odd This setting shall be non-volatile with a default setting of Even. 40203 The value changes will only take effect following a hardware reset of the control board Units Required by the control board for capacity calculations 40204 0=LBS, 1=KG Unit type Required by the control board for current and capacity calculations 40205 Depending on the setting in UNITS (Modbus: 40204) Hex value representing maximum unit capacity (100% fill off amps) Unit voltage Required by the control board for current and capacity calculations 40206 Hex Value Unit Type 0 110-120 1 208 2 220-240 3 230 4 277 5 347 6 380 7 400 8 415 9 440-480 A 550-600 Unit phase Required by the control board for current and capacity calculations 40207 Bit Allocation Single phase = 1 Three phase = 2 Three phase (6 electrode) = 4 Electrode current The value of the electrode current in Amps 30104 Hex value representing the humidifies current in amps Resolution: 0.10 amps Example: 015F (hex) = 35.1 Amps Operation | 28 Function Description Address Details Steam output The current steam output in Kg/Hr. or LBS/hr See UNITS (Modbus 40031) 30105 Hex value representing the humidifies steam output in kg/hr Resolution: 0.10 kg or LBS Example: 013B (hex) = 31.5 kg/hr or LBS/hr Run hour counter The number of hours the humidifier has been in operation since the last time the run hour counter was reset 30106 Hex value representing the number of humidifier operational hours since the last reset. Resolution: 5 minutes Maximum count: 5460 Hours. Example: 07D0 = 2000 hours Humidifier state Describes the current state of the humidifier and it’s I/O’s Contactor ON/OFF Fill Valve ON/OFF Drain Valve ON/OFF 30107 Bit Allocation Note More than one bit can be active at any time. Contactor on = 1 Fill valve on = 2 Drain valve on = 4 Alarms The humidifier shall describe any faults Too long to fill Excess Current End of cylinder life No current 30108 Bit Allocation Note More than one bit can be active at any time. Too long to fill = 1 Excess current = 2 End of cylinder life = 4 No Current = 8 Maximum production The rated maximum steam production for the humidifier 30111 Value written into Unit type (40205) is also stored here Firmware version The firmware version of the humidifier controller 30113 Packed BCD version3.52 would be 0x0352 29 | Operation Start Up Procedure 1 Examine the humidifier and installation for damage and or improper installation. Warning: Damaged Units or improperly installed units must not be operated. Damaged or improperly installed units may present a danger to persons and property. 2 If enclosed plumbing option is installed ensure that the front cover is in place and secured with its retaining screw. 3 Open the supply water shut off valve. 4 Turn on the mains power using the installed disconnect. 5 Turn the On/Off switch to the “On” position. The humidifier will perform a self-diagnostic sequence during which the LED’s and internal components will be momentarily activated. If an error is detected during the self-diagnostic sequence the humidifier will not start. The yellow status LED will flash in sequence to indicate the detected fault. See Table 7: Troubleshooting MES2 Faults on page 43 for information on diagnosing and correcting faults. After the system test the humidifier is in normal operation mode. 6 Check and adjust the control setpoint on the control and high limit humidistat. 7 When the external humidistat generates a demand for humidity and the security loop is closed the green humidifying LED on the front of the humidifier will light up, the power relay on the control board will engage, the fill valve will activate (after a delay) and the cylinder will slowly fill with water. Note: While the cylinder is filling with water there should be no water flowing down the drain. If water is flowing down the drain it can indicate excessive backpressure or a leaking drain valve. See chapter on troubleshooting starting on page 39. 8 It can take some time for the water to be heated up by the submerged electrodes and for steam to be produced. Once the fill valve shuts off after reaching the appropriate water level, the water in the cylinder will start to heat up until steam is generated. Note: If operated on low conductivity water it may take several hours for the MES2 to reach full output capacity. This is normal. During this time the humidifier will not perform any drains and the conductivity of the water in the cylinder will increase. Operation | 30 Maintenance and Servicing 32 Required Maintenance 32 Cylinder Spent Fault 32 Replacement Cylinder 33 Removing the Cylinder 34 Drain Valve Cleaning 35 Installing the New Cylinder 36 Extended Shutdown 36 Starting After Extended Shutdown 37 MES2 Maintenance Checklist 31 | Maintenance and Servicing Required Maintenance The MES2 humidifier has been designed to require very little maintenance. Regular maintenance consists of checking the humidifier to insure it is in good condition, replacing the cylinder when the software advises that the cylinder is spent and cleaning out the drain valve whenever the cylinder is replaced. Cylinder Spent Fault When the cylinder is spent the MES2 will stop operating and the yellow LED will flash in a repeating pattern of 4 flashes. At this time the cylinder must be replaced. See Table 7: Troubleshooting MES2 Faults on page 43 for more information on other flash sequences. The steam cylinder is disposable and must be replaced at end of cylinder life. Cylinder life is dependent on water supply conditions and humidifier usage. Caution: Failure to replace the cylinder at the end of cylinder life will result in improper operation and may result in damage to the humidifier. Nortec is not responsible for any damages resulting from, or attributed to, the failure to replace a spent cylinder (see Manufacturer’s Warranty). Note: Nortec recommends keeping a replacement cylinder in stock throughout the humidification season. This will prevent possible downtime when the humidifier reports cylinder end of life. Replacement Cylinder The label on the existing cylinder identifies the cylinder type in its top left corner. When ordering a cylinder always quote the three or five digit model number on the label, the humidifier’s serial number, and the humidifiers voltage. Serial number and voltage are located on the specification label on the left side of the humidifier. Steam Outlet Secure steam hose to outlet with hose clamp. High Water Sensor Pin Has a plastic collar around it. Connect orange high water sensor wire here. Electrode Pin Connect color coded cylinder plugs to pin with corresponding color label. There may be 2 or 3 connections depending on cylinder. The spring loaded plug should fit snugly on the pin. Replace if loose or any signs of damage. Label Identifies cylinder type in top left. Always replace cylinder with the same model. Figure 23: MES2 Cylinder Maintenance and Servicing | 32 Removing the Cylinder Warning Check to see if yellow service LED is flashing (see Figure 20: User Interface on page 24) then disconnect main power at the external disconnect before any servicing. The inside of the humidifier’s cabinet contains high voltage components and wiring. Access should be limited to authorized personnel. 1 Drain the existing cylinder by switching the On/Off/Drain switch to the Drain position. Let the humidifier drain until no more water is flowing out to drain (usually not more than 10 minutes). 2 Turn the humidifier On/Off/Drain switch to off. 3 Close supply water shut off valve. 4 Turn off power to the humidifier with the external disconnect. 5 If enclosed plumbing option is installed remove the screw securing the front cover. 6 Remove the cylinder plugs from the cylinder pins by pulling vertically. 7 Using a flat screwdriver loosen the hose clamp where the hose is connected to the cylinder. 8 Using a small flat screwdriver press the tab on the cable tie holding the cylinder in place and pull the cable tie open. 9 Tip the top of the cylinder forward to pivot it out of the steam hose. When free of steam hose lift the cylinder out. Cylinder Plug lift vertically Hose Clamp Tilt cylinder forward to clear hose and then lift from drain valve. Cable Tie On/Off/Drain Switch Figure 24: Cylinder Removal 33 | Maintenance and Servicing Drain Valve Cleaning Always clean the drain valve before installing a new cylinder. Scale from the spent cylinder may have fallen into the drain valve and could prevent its proper operation. To properly clean the drain valve it must be removed and disassembled. Note: Be sure to reattach the green ground wire to reduce the risk of electrical shock. 1 Disconnect spade terminals from the drain valve. 2 Remove the screw holding the green ground wire and the two screws holding the valve to the drain pan. 3 Squeeze the tabs of the spring clamp holding the hose to the drain valve and slide it up the hose. Pull hose from drain valve. Lift the drain valve from the drain pan. 4 Unsnap red coil cap on solenoid and remove the solenoid from the valve. 5 Loosen brass nut holding actuator to plastic housing with a wrench and disassemble actuator. 6 Clean actuator components and valve housing (inlet port, outlet port, and cylinder port). Put new o-ring that was supplied with new cylinder into valve. 7 Reassemble actuator making sure tapered end of spring is oriented as shown Figure 26. Tighten brass nut 1/4 turn past hand tight. 8 Clean out end of hose and reattach to valve. Slide hose clamp back in place and place valve into drain pan. 9 Secure valve with 2 screws and attach green ground wire to solenoid. Cylinder Port and O-ring Ground Wire Hose and Hose Clamp Solenoid Screws Brass Nut (Actuator) Spade Connectors Figure 25: Drain Valve Maintenance and Servicing | 34 Plunger Spring (Note Orientation) Sleeve and Solenoid Figure 26: Drain Valve Actuator Assembly Installing the New Cylinder CAUTION: Make sure the new cylinder is the same model as the one that was removed. Model number is on top left corner of cylinder label. 1 Insert cylinder into drain valve. Tilt cylinder forward and fit end of steam hose to steam outlet. Tip cylinder back into place. 2 Secure cylinder with the reusable cable tie. Tighten hose clamp being careful not to over tighten and crush the plastic cylinder steam outlet. 3 Attach color-coded cylinder plugs to the corresponding color-coded cylinder pin. Push down completely. Connect high water sensor plug. Spring-loaded plugs should fit snuggly onto the cylinder pin. Replace if they are loose or damaged. 4 If enclosed plumbing option is installed replace the humidifier cover and secure with screw. 5 Turn on power to humidifier with the external disconnect. 6 Open supply water shut off valve. 7 Turn the humidifier On/Off /Drain switch to On. 35 | Maintenance and Servicing Extended Shutdown Should it be required to disconnect power to the humidifier for a period of extended shut-down, always drain the cylinder first. Otherwise, the electrodes are subject to harmful corrosion which drastically shortens the cylinder life. 1 2 3 4 5 Switch the On/Off/Drain Switch to the Drain position. Wait until the humidifier is completely drained (usually takes less than 10 minutes). Turn the On/Off /Drain switch to the off position. Shut off power to the humidifier with the external disconnect. Close the supply water shut-off valve. Caution: Do not leave the switch in the DRAIN position indefinitely as the drain coil could burn out. When disconnecting power to the humidifier for an extended period of time drain the cylinder first to prevent harmful corrosion. Note: As long as the MES2 is powered, it will automatically drain the cylinder when there has not been a call for humidity for an extended period of time. This feature will reduce or prevent the possibility of corrosion of the electrodes and the accumulation of algae and bacteria growing in the cylinder. The cylinder will remain empty until there is a call for humidity at which time the fill valve will open and refill the cylinder. The unit will go through its normal process for optimum operation. Starting After Extended Shutdown 1 Check to see the humidifier has not been damaged and the installation has not been altered. 2 Open the supply water shut-off valve. 3 Turn on the power to the humidifier with the external disconnect. 4 Turn the On/Off/ Drain switch to the On position. 5 Follow the start up procedure in the section titled Start Up Procedure on page 30. Maintenance and Servicing | 36 MES2 Maintenance Checklist Model #: _________________ Serial #: _________________ Cylinder #: Tag: ________ CHECK CYLINDER Cylinder spent), yellow LED flashing 4 times in sequence. (If Yellow LED is On and cylinder is not new then cylinder will have to be replaced soon.) REPLACE CYLINDER Cylinder drained. Disconnect open, On/Off/Drain switch off, water shut off valve closed, cover removed. Cylinder removed Drain valve removed / cleaned / new O-Ring installed Drain valve cleaned / installed / ground wire attached. New Cylinder Installed New cylinder model # (Should be same as removed cylinder) Cylinder plug colors match cylinder dots. Cylinder plugs snug and in good condition. High Water Sensor plug snug and in good condition. Steam hose attached. Cover replaced, water shut off valve open, On/Off /Drain switch On, Disconnect Closed SYSTEM CHECK Yellow Led flashing? Primary power disconnect turned off Cylinder plugs snug and in good condition. Electrical wiring not loose and in good condition, Steam hoses and steam lines in good condition / No kinks in hose, No Signs of water leaking around humidifier, steam line, condensate returns, Cover replaced, water shut off valve open, On/Off /Drain switch On, Disconnect Closed No Flash Sequence? (See Troubleshooting Chapter for actions if yellow LED is flashing) Inspected by: Company: 37 | Maintenance and Servicing Yes Date of inspection: _______/_______/______ Maintenance and Servicing | 38 Troubleshooting 40 Organization of Troubleshooting Chapter 40 Troubleshooting Requirements 41 General Troubleshooting 41 Humidifier 42 Steam Distributors 42 Modbus 42 MES2 Faults 43 LED Flash Sequence 43 Clearing a Fault 45 MES2 Wiring Diagram 39 | Troubleshooting Organization of Troubleshooting Chapter The troubleshooting chapter is broken down into 2 sections. General Troubleshooting Deals with troubleshooting incorrect humidifier operation, steam line and plumbing issues without any control software faults. Humidifier Warnings and Faults Deals with faults that are generated by the humidifier’s control software. CAUTION: Be aware, when troubleshooting, that the humidifier is powered by high voltage and familiarity with both good practices and wiring of the humidifier is recommended. Any troubleshooting should be done by qualified personnel. NOTE: Check if yellow service LED is flashing before turning off the humidifier to determine if a fault has occurred. See Figure 20 on page 24 and Table 7 on page 43. Most humidifier faults are not caused by faulty equipment but rather by improper installation. A complete fault diagnosis always involves a thorough examination of the entire system. Often, the steam hose connection has not been properly executed, or the fault lies with the humidity control system. Troubleshooting Requirements Ensure the installation meets the installation requirements outlined in the Installation Chapter of this manual. Familiarize yourself with the operation of the humidifier by reading the Operation Chapter on page 24 and the section describing How the Humidifier Works on page 9 in this manual. A generic copy of the MES2 wiring diagram is included at the end of this chapter for reference purposes. When contacting your local representative or Nortec for troubleshooting assistance, please ensure the serial number has been obtained for reference purposes. Troubleshooting | 40 General Troubleshooting The following section provides general guidelines for troubleshooting the MES2 humidifier and auxiliary components. For detailed troubleshooting information refer to the manuals that were provided with auxiliary equipment and to Table 7: Troubleshooting MES2 Faults on page 43. Humidifier Table 6: General Troubleshooting Symptom Nothing happens when On/Off switch is turned on. Humidifier will not humidify or not reaching RH setpoint Cause Corrective Action(s) 1 Fuse blown 1 Check inline fuse between On/Off/Drain switch and control board. 2 Incorrect Voltage 2 Check voltage supplied to On/Off/Drain switch is 24 VAC. 3 Mains power turned off 3 Turn on mains power. 1 Safety loop open. No 24 VAC at 2. 1a Check if there is 24 VAC at point 2 of Terminal P3 on the control board. 1b Check if air handler is outputting 24 VAC run signal. 1c Check wiring and operation of On/Off devices connected in series between output calling for humidity and point 2 of terminal P3. 2 No demand signal (If J10 removed for modulation) 2 Check voltage between P5 and ground. 25% of full-scale signal must be present for humidifier to start. 3 Not configured correctly for On/Off or modulating control 3 Check that J10 on control board is removed for modulating control and installed for On/Off control. 4 Capacity has been manually limited 4 Check Manual Capacity adjustment potentiometer. Clockwise increases capacity. 5 Low conductivity water 5 Check if yellow LED is on. If operated on low conductivity water it may take several hours for the MES2 to reach full output capacity. This is normal. During this time the humidifier will not perform any drains and the conductivity of the water in the cylinder will increase. 6 Humidifier undersized Humidifier has faulted and yellow LED is flashing 41 | Troubleshooting 1 Software has detected an abnormal condition 1 Refer to Table 7: Troubleshooting MES2 Faults. Steam Distributors Symptom Distributor spitting out water Cause Corrective Action(s) 1 Distributor not level 1 Use support at end of distributor to ensure it is level. 2 “P” Trap too close to distributor 2 “P” Trap must be a minimum of 12 in (30 cm) below the distributor to ensure flow. Relocate if required. 3 Condensate line not sloped sufficiently 3 Sufficient slope to insure flow is required. Reinstall if required. 4 Trap blocked 4 Check that water flows through trap. Clear out if blocked. 5 Steam line not insulated 5 If steam line is long condensate build up could overload distributor condensate port. Insulate line to improve efficiency and install additional condensate traps as required. 6 Incorrect steam line installation 6 Check that steam line has been installed with condensate traps and slope per installation instructions on page 16. 7 Humidifier foaming and foam carried up steam line. 7a Check if foaming caused by short cycling. 7b Check if foaming caused by blocked or restricted drain. 7c Check if steam line is causing back pressure and preventing proper filling. Condensation in Air Handler 1 Installation clearances not observed 1 Refer to distributor installation manual for required clearances. Relocate distributor if required. 2 Design conditions changed 2 Check supply air temperature and humidity to determine if conditions have changed. 3 High limit not functioning 3 Check setting and operation of high limit. Replace if defective. Modbus Symptom No Modbus Communication Cause 1 Incorrect Wiring Corrective Action(s) 1a Use 18/24 AWG Shielded Twisted Pair, 120 Ω cable. 1b. Connect shield to one end only. 1c. Check polarity of data wires. 2 Incorrect Communication Parameters 2 Defaults are 9600 B/sec, Modbus Address 1, Even Parity 3 Noise interference 3a Route data cable away from noise generating devices. 3b Install an RS485 repeater. Troubleshooting | 42 MES2 Faults The self-diagnostic system built into the MES2 is continually monitoring the operation of the humidifier. When an abnormal condition occurs that cannot be self corrected by the software the MES2 will turn off power to the cylinder, drain the cylinder, and annunciate the fault using the yellow status LED. LED Flash Sequence To differentiate between different fault conditions the yellow LED is flashed in different sequences. Table 7 lists MES2 faults, their meaning, possible causes, and corrective actions. Clearing a Fault Check the flash sequence against the list of fault messages and take any necessary actions to correct the cause(s) as outlined in Table 7: Troubleshooting MES2 Faults. Power cycle the humidifier with the On/Off switch. Wait 3 seconds between off and on. Table 7: Troubleshooting MES2 Faults Yellow LED System Detected Cause Corrective Action(s) 1 Drain blocked water over concentrated 1 Clean the drain line and drain valve. 2 Drain solenoid not energized, water over concentrated 2 Check and correct wiring to drain valve. 3 Filling too fast, fill valve damaged 3 Check fill rate and replace the fill valve if needed. 4 Water supply too conductive 4a Contact Nortec representative for recommendation on alternate cylinder 4b Change the water supply 5 Humidifier short cycling Excess Current 1 flash Current has exceeded 130% of max 5a Check if high limit or other On/Off control is cycling On/Off in less than 5 minutes. Check location and setting of high limit. 5b Reduce the output by turning down the capacity potentiometer. 5c If modulating control check if controller Pband too tight. 5d Check for temperature swings. 43 | Troubleshooting 6 Wrong cylinder installed 6 Install correct cylinder model 7 Cylinder Spent but not detected by software 7 Replace the cylinder (see maintenance chapter) 8 Condensate from other source 8 Remove condensate returns other than from steam line. 9 Back pressure 9 Eliminate back pressure Table 7: Troubleshooting MES2 Faults (Continued) Yellow LED System Detected Cause 1 Drain valve leaking or stuck open 1 Clean drain valve or replace (see maintenance chapter) 2 Water shut off valve closed 2 Open shut off valve 3 Fill Valve strainer blocked 3 Clean out strainer on fill valve 4 High system back pressure 4a Check for kinked hose 4b Check for proper condensate removal (see installation chapter) No Current 2 flashes Fill valve activated for long time but high water level not reached. Fill should be faster than 1” per minute. Corrective Action(s) 5 High water sensor not connected 5 Check that cylinder plug with white marker is connected to short electrode with a plastic collar around it and to control board. 6 Low water conductivity 6a Check conductivity of water. If less than 150 microsiemens contact factory for recommendation. 6b Add 1/4 teaspoon of salt to fill cup and restart unit. No Current, High Water 3 flashes Water level at top of cylinder with no current Cylinder Spent 4 flashes Electrodes covered with scale. 1 Primary wire not looped through current transformer. 1 Open disconnect, rewire primary wire through current transformer. 2 1 phase of 3 phase supply blown 2 Check that all phases are energized. 3 High water sensor plug is on an electrode pin. 3 Install high water senor plug on cylinder pin with collar around it. 4 Cylinder plugs installed incorrectly 4 Check that cylinder plugs colors match markers next to electrodes on cylinder and that white marked cylinder plug is connected to pin with collar around it. 1 Cylinder electrodes are calcified. 1 Replace cylinder with same model number (see maintenance chapter) 2 Software incorrectly detected cylinder is spent 2a If fault has occurred shortly after start up then check for low water conductivity. (See 2 flashes cause 6) 2b Check if water in cylinder is foaming. If yes see 1 flash Excess current causes. Troubleshooting | 44 Control Signal (0-10 Vdc, 2-10 Vdc) (-) (+) DRAIN 24 Vac Hot Modulation: Remove J10 for 0-10 VDC Remove Jumper J10 and place it on J13 for 2-10VDC 24 VAC Common MES2 Wiring Diagram ON/OFF Safties FILL Amp S 3Fuse Drain OFF ON Primary Terminal Block (by others) L1 L2 L3 Contactor 24 Vac (by others) 3 2 1 Fault Indication N.O Yellow LED Mains Voltage Select Jumpers J10 Green LED RS485/TTL Common B A Modbus Interface Board (1509592) J6 208V J5 230V J4 277V J3 380-415V J2 460V J1 575V 3 2 1 J7 J6 J5 J4 J3 J2 J1 Install J26 For Modbus Control J13 Calibration (Do not ajust!) HW Sensor Jumpers R52 J9 Low Voltage 200-277V J8 High Voltage 380-600V 1509591 Capacity adjust J9 J8 2 or 3 electrode cylinder NOTE: Dotted lines denote wiring by others with the exception of Primary Voltage Wiring ( PVW ) units which will come with all primary wiring to the cylinder and 10’ of wiring to run the electrical back to the contactor MES2 with Optional Modbus board WIRING DIAGRAM DIAGRAM NUMBER 2553788 Rev. B DATE August 18, 2010 Figure 27: MES2 Wiring Diagram 45 | Troubleshooting Exploded View and Spare Parts List Spare Parts| 46 MES2 Spare Parts 8 7 10 9 6 1 2 5 3 4 11 17 16 12 13 14 15 Figure 28: MES2 Spare Parts 47 | Spare Parts Table 8: MES2 Spare Parts List Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Description Part No. 5 lb/hr 2.3 kg/hr 10 lb/hr 4.5 kg/hr 15 lb/hr 6.8 kg/hr 20 lb/hr 9.1 kg/hr 25 lb/hr 11.4 kg/hr 30 lb/hr 13.6 kg/hr PCB MES2, 208-600V, 1 PH 2554100 2554101 2554102 2554104 PCB MES2, 208-600V, 3 PH 2554103 2554105 2554106 2554107 PCB Modbus Interface 1509592 1 1 1 1 1 1 Switch Bracket 2554036 1 1 1 1 1 1 Switch Rocker SPDT 1323097 1 1 1 1 1 1 Connector, 2 Pole 1703972 3 3 3 3 3 3 Connector, 3 Pole 1703973 1 1 1 1 1 1 Enclosed Plumbing 2554073 1 Option 2554074 1 2554075 1 1 2554076 1 1 Cylinder To order quote 3 digit number on existing cylinder, or Ser. No, Model, & Voltage Cyl. Plug Black Marker 1510046 1 1 1 1 1 1 Cyl. Plug Red Marker 1510047 1 1 1 1 1 1 Cyl. Plug White Marker 1510048 1 1 1 1 1 1 Cyl. Plug Yel. Marker 1510049 1 (Three phase humidifiers only) Tie Wrap Reusable 1513003 1 1 1 1 1 1 Fill Cup Assembly 2554069 1 2554070 1 2554071 1 1 2554072 1 1 Drain Valve and Coil 1456000 1 1 1 1 1 1 Gasket Drain Canal 1631026 1 1 1 1 1 1 Drain Canal Round 1102503 1 1 1 1 1 1 Washer Drain Canal 1325046 1 1 1 1 1 1 Screw #6-32x1.5 1325064 1 1 1 1 1 1 Fill Valve 005-020 1321061 1 1 1 1 Fill Valve 025-030 1321062 1 1 Fitting 3/4 to 1/8 1495072 1 1 1 1 1 1 Spare Parts| 48 Warranty Nortec Humidity Ltd. (hereinafter collectively referred to as THE COMPANY), warrant for a period of two years after installation or 30 months from manufacturer’s ship date, whichever date is earlier, that THE COMPANY’s manufactured and assembled products, not otherwise expressly warranted (with the exception of the cylinder), are free from defects in material and workmanship. No warranty is made against corrosion, deterioration, or suitability of substituted materials used as a result of compliance with government regulations. THE COMPANY’s obligations and liabilities under this warranty are limited to furnishing replacement parts to the customer, F.O.B. THE COMPANY’s factory, providing the defective part(s) is returned freight prepaid by the customer. Parts used for repairs are warranted for the balance of the term of the warranty on the original humidifier or 90 days, whichever is longer. The warranties set forth herein are in lieu of all other warranties expressed or implied by law. No liability whatsoever shall be attached to THE COMPANY until said products have been paid for in full and then said liability shall be limited to the original purchase price for the product. Any further warranty must be in writing, signed by an officer of THE COMPANY. THE COMPANY’s limited warranty on accessories, not of the companies manufacture, such as controls, humidistats, pumps, etc. is limited to the warranty of the original equipment manufacturer from date of original shipment of humidifier. THE COMPANY makes no warranty and assumes no liability unless the equipment is installed in strict accordance with a copy of the catalog and installation manual in effect at the date of purchase and by a contractor approved by THE COMPANY to install such equipment. THE COMPANY makes no warranty and assumes no liability whatsoever for consequential damage or damage resulting directly from misapplication, incorrect sizing or lack of proper maintenance of the equipment. THE COMPANY makes no warranty and assumes no liability whatsoever for damage resulting from freezing of the humidifier, supply lines, drain lines, or steam distribution systems. THE COMPANY retains the right to change the design, specification and performance criteria of its products without notice or obligation. Warranty | 50 U.S.A. 1860 Renaissance Blvd. Sturtevant, WI 53177 826 Proctor Avenue Ogdensburg, NY 13669 CANADA 2740 Fenton Road Ottawa, Ontario K1T 3T7 TEL: 1.866.NORTEC1 EMAIL: [email protected] WEBSITE: www.humidity.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement