Electrolux Modular Compact Short, USA Modular, Modular, Compact USA Rack-Type Dishwashers SERVICE MANUAL
Reklama
Reklama
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
SERVICE MANUAL
MODULAR AND COMPACT
RACK-TYPE DISHWASHERS
U
U
CONTENTS: This document contains all the parameters and information for programming the electronic boards.
EDITION: 03.2010
Valid for firmware versions
• 1.65 COMPACT SHORT
• 1.67 USA MODULAR
• 1.66 MODULAR
• 5.01 COMPACT USA.
WARNING:
All the safety regulations and procedures to be followed by the Specialised Technician/Technical Assistance performing electrical, mechanical or electronic maintenance operations are contained in the instruction manual supplied with the machine: refer to this document before operating. This applies for anyone carrying out operations using these documents. The specialised technician must wear personal protection equipment suitable for the work being performed (e.g. gloves, safety glasses and shoes, suitable clothing, etc.) and use appropriate tools, equipment and auxiliary means.
DOC. NO. 5956.573.04
P. 1 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
INDEX
MODULAR MACHINES (NO USA) .....................................................................
COMPACT MACHINES AND USA MODULAR VERSIONS ...............................
A2 ACCESSING THE USER MENU AND SERVICE MENU................................................
A3 USER MENU (NOT AVAILABLE FOR USA COMPACT RACK TYPES)........................
A3.1
EXIT ....................................................................................................................
DATA SETTING (FOR NON USA MODULAR RACK TYPES ONLY) .................
Pag.7
NON USA MODULAR RACK TYPES ...............................................
USA MODULAR AND COMPACT SHORT RACK TYPES ...............
A4 SERVICE MENU .............................................................................................................
Pag.10
USER SETTINGS (ONLY FOR MODULAR RACK TYPE NO USA) Pag.10
A4.1.2
GENERIC FUNC...............................................................................
Pag.11
A4.1.3
RINSE MODULE...............................................................................
Pag.19
A4.1.4
WASH MODULE ...............................................................................
Pag.20
A4.1.5
PREWASH MODULE........................................................................
Pag.22
A4.1.6
DT MODULE .....................................................................................
Pag.24
A4.1.7
HACCP .............................................................................................
Pag.26
RATING PLATE (ONLY FOR MODULAR RACK TYPE NON USA) .
DATALOG (ONLY FOR MODULAR RACK TYPE NON USA).............................
A4.3
INFO ....................................................................................................................
Pag.33
A4.4
STATISTICS (ONLY FOR MODULAR RACK TYPE NON USA) .........................
Pag.33
A4.5
RINSE CONTROL ( JUST FOR ATMOSPHERIC RACK TYPE ) .......................
Pag.34
KEY MANAGEMENT ( JUST FOR MODULAR RACK TYPE ) ...........................
SETTING UNIT OF MEASURE IN FAHRENHEIT ..............................................
“MAX. MOTOR CURR.” PARAMETER (
GCU ) SETTING ..................................
C1 POWER BOARDS CONNECTORS LAYOUT .................................................................
C2 MULTICONNECTOR BOARDS CONNECTORS LAYOUT .............................................
C4 END LIMIT SWITCH, ENERGY PEAK CONTROL AND EMERGENCY SWITCH
C4.1
MODULAR (NO USA) ......................................................................................... Pag.
83
END LIMIT SWITCH CONNECTION ................................................ Pag.
EMERGENCY SWITCH CONNECTION........................................... Pag.
ENERGY PEAK CONTROL CONNECTION..................................... Pag.
USA MODULAR AND COMPACT SHORT ......................................................... Pag.
C4.3
USA COMPACT .................................................................................................. Pag.
85
C4.3.1
END LIMIT SWITCH CONNECTION ................................................ Pag.
85
EMERGENCY SWITCH CONNECTION........................................... Pag.
ENERGY PEAK CONTROL CONNECTION..................................... Pag.
DOC. NO. 5956.573.04
P. 2 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
INVERTER CONTROL TERMINAL ELECTRICAL CONNECTIONS..................
D1.3
INVERTER PARAMETER LISTS ........................................................................
Pag.87
E WARNING MESSAGES AND TROUBLESHOOTING ..................................... Pag.90
F MODULE COMPOSITION FOR RACK TYPE.................................................. Pag.94
G FLOWCHARTS FOR TROUBLESHOOTING .................................................. Pag.95
INDEX OF FIGURES AND TABLES
Figure 3 Accessing the USER MENU .............................................................................................. Pag.6
Figure 4 Accessing the SERVICE MENU ........................................................................................ Pag.6
Figure 6 Parameter and function access menu chart for Compact Short Rack Type and USA
Figure 8 Scheme for “Heat two comm.” parameter and “Heating manage” parameter (only for
Modular Rack Type) ........................................................................................................... Pag.15
Figure 9 Scheme for “H2C” parameter and “b_t” parameter (only for Compact Rack Type)............ Pag.15
Figure 10 Electrical connection .......................................................................................................... Pag.83
Figura 14 END LIMIT SWITCH AND EMERGENCY SWITCH CONNECTION ................................. Pag.85
N.B.: The red text of the document indicate additions with respect to the previous edition.
DOC. NO. 5956.573.04
P. 3 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
A FUNCTION KEYS
BUTTONS USED
A B C D E
U
Figure 1 Menu access keys
A1 DISPLAY OF AUXILIARY VALUES
From the normal machine operation mode it is possible to see several screens not accessible to the user.
These screens give various machine values, and are accessed by pressing at the same time the combina-
tions of buttons displayed. (Figure 2).
U
U
Figure 2 Accessing current, temperatures and levels display mode
A1.1
MODULAR MACHINES (NO USA)
to access the screen displaying the levels of the various tanks and airgap.
Prewash 200 mmH2O
Wash 195 mmH2O
Airgap
DUO
60 mmH2O
55 mmH2O
DOC. NO. 5956.573.04
P. 4 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
motor.
Mot. Curr.
35 decA
To return to the standard display, wait 30 seconds or press the Confirm button - “C” (Figure 1) -.
A1.2
COMPACT MACHINES AND USA MODULAR VERSIONS
quent screens. The following screens are displayed ( in order) :
1
Adt tmp
68
DT temperature
(significant only for machines with DT)
2
b_U tmp
138
Temperature of first boiler
(significant only for compact USA machines with 2 boilers)
3
AIG
LE
60
Air Gap level
(significant only for atmospheric machines)
4
tAn
LE
198
Wash tank level
5
sCp
LE
204
Prewash tank level
(significant only for machines with prewash)
6
dUO
LE
45
Duo tank level
(significant for USA modular versions only)
7
Mot
Cur
34
Gear motor current
To return to the standard display, wait 30 seconds or press the Confirm button - “C” (Figure 1) -.
DOC. NO. 5956.573.04
P. 5 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
A2 ACCESSING THE USER MENU AND SERVICE MENU
From normal machine operation mode all the parameters and information can be accessed for programming the electronic boards by pressing the combinations of keys displayed in (Figure 3) and in (Figure 4).
U
U
Figure 3 Accessing the USER MENU Figure 4 Accessing the SERVICE MENU
From the USER MENU and SERVICE MENU it is possible to access the following parameter families and infor-
USER MENU SERVICE MENU
EXIT
DATA SETTING CONSUMPTION
PARAMETERS DATALOG INFO STATISTICS RINSE CONTROL KEY MANAGEM.
SENS. ADJUST.
MOTOR ADJUST.
USER
SETTINGS
GENERIC FUNC.
RINSE
MODULE
WASH
MODULE
PREWASH
MODULE
DT
MODULE
HACCP RATING
PLATE
Figure 5 Parameter and function access menu chart for Modular Rack Type (no USA)
USr
(USER MENU)
FAC
(SERVICE MENU)
ESC
(EXIT)
Con
(CONSUMPTION)
PAr
(PARAMETERS)
Inf
(INFO)
rfC
(RINSE CONTROL)
SAd
(SENSOR ADJUST.)
GAd
(MOTOR ADJUST.)
GFu
(GENERIC
FUNC.)
RiN
(RINSE
MODULE) tub
(WASH
MODULE) pRE
(PREWASH
MODULE)
Dt
(DT MODULE)
HAC
(HACCP)
Figure 6 Parameter and function access menu chart for Compact Short Rack Type and USA Modular versions
DOC. NO. 5956.573.04
P. 6 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
FAC
(SERVICE MENU)
PAr
(PARAMETERS)
Inf
(INFO)
rfC
(RINSE CONTROL)
SAd
(SENSOR ADJUST.)
GAd
(MOTOR ADJUST.)
GFu
(GENERIC
FUNC.)
RiN
(RINSE
MODULE)
tub
(WASH
MODULE)
pRE
(PREWASH
MODULE)
Dt
(DT MODULE)
HAC
(HACCP)
Figure 7 Parameter and function access menu chart for Compact USA Rack Type
A3 USER MENU (NOT AVAILABLE FOR USA COMPACT RACK TYPES)
for several seconds to access the USER MENU.
1
USER MENU
3
1 - EXIT
2 - DATA SETTING
USr
ESC
The current date and time used in recording events (see par. A4.2 DATALOG (ONLY FOR MODULAR RACK
TYPE NON USA)) and statistics (see A4.4 STATISTICS (ONLY FOR MODULAR RACK TYPE NON USA))
can be set inside the USER MENU.
WARNING:
At first machine start-up make sure the date and time are correctly set.
Display the number of racks processed by the machine and machine consumption.
A3.1
EXIT
Press the confirm key (“C” - (Figure 1)) when the selection arrow indicates the item EXIT
(
ESC)
to return to normal machine operation.
A3.2
DATA SETTING (FOR NON USA MODULAR RACK TYPES ONLY)
display will show the set date and time:
DATE & TIME
09 NOV 05
14 : 25
DOC. NO. 5956.573.04
P. 7 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
The display shows the current date at the bottom and the date being set at the top.
SET DATE
MAY
09 NOV 05
09 NOV 05
Use the increase, decrease and confirm keys to modify the date.
To modify the set time, select the time with the increase and decrease keys and press the confirm key.
The display shows the current time at the bottom and the time being set at the top.
SET TIME
15 : 25 : 32
14 : 25 : 32
Use the increase, decrease and confirm keys to modify the time.
A3.3
CONSUMPTION
A3.3.1
NON USA MODULAR RACK TYPES
the display will show the counter of the racks processed by the machine.
CONSUMPT.
BASKETS NUMBER
0
RESET CONS DD-MM-YY HH:MM
0 02-11-00 10:25 FAC
The display shows the number of racks starting from the date of machine installation. The number of racks processed, counted starting from the date indicated opposite, corresponding to the last reset (RESET CONS) is also displayed.
In fact the rack counter can be reset by pressing the confirm button; in this way the “CONSUMPTION RESET” mode is accessed.
CONSUMPT. RESET
BASKETS NUMBER
0
RESET CONS DD-MM-YY HH:MM
0 02-11-00 10:25 FAC
Press the confirm button again to reset the resettable rack counter.
The rack counter is reset and the date and time of the last reset are saved.
If the last counter reset occurred in the factory, the message FAC appears next to the reset time.
Press the additional functions button to exit the “CONSUMPTION RESET” mode.
Use the increase and decrease buttons to display the screens relevant to:
rinse module water consumption (litres)
wash module water consumption (litres)
prewash module water consumption (litres)
machine power input (kwatt/h)
DOC. NO. 5956.573.04
P. 8 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WARNING:
To have the above information the machine must be equipped with suitable flow meters (water consumption) and/or a suitable energy measurer and the Pulse/lit rinse, Pulse/lit wash, Pulse/lit prewash, Pulse/kWattH parameters must be correctly set.
Also these screens provide for 2 counters, one resettable and the other non-resettable, usable as described above.
A3.3.2
USA MODULAR AND COMPACT SHORT RACK TYPES
Press the confirm button (“C” - (Figure 1)) when the item
Con
(CONSUMPTION) is selected, and the display will show the counter of racks processed by the machine.
itE nbr
0
0
168
The number of racks processed and the item to which the number shown refers are displayed alternately. To obtain the total number of processed racks, form the numbers displayed as follows:
2
059
165
number of racks = 2059165
The display shows the number of racks starting from the date of machine installation. The number of racks processed starting from a reset operation can also be displayed.
In fact, the rack counter can be reset by pressing the confirm button; in this way the “CONSUMPTION
RESET” mode is accessed.
rES itE nbr
0
0
20
Press the confirm button again to reset the resettable rack counter. The rack counter is reset.
Press the additional functions button to exit “CONSUMPTION RESET”mode.
Use the increase and decrease buttons to display the screens relevant to:
rinse module water consumption (litres)
wash module water consumption (litres)
prewash module water consumption (litres)
WARNING:
To have the above information the machine must be equipped with suitable flow meters (water consumption) and the
PLr
, PLt, PLP
parameters must be correctly set.
Also these screens provide for 2 counters, one resettable and the other non-resettable, usable as described above.
DOC. NO. 5956.573.04
P. 9 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
A4 SERVICE MENU
for several seconds to access the SERVICE MENU.
MODULAR RACK TYPE COMPACT RACK TYPE AND USA MODULAR
1
SERVICE MENU
3
1 - PARAMETERS
2 - DATALOG
Inside the SERVICE MENU it is possible to:
• display and edit all the machine parameters;
• access the DATALOG, i.e. a file of events that occurred during machine operation (only for modular rack type);
• display information of a general nature, such as the machine software versions;
• consult a file of statistics relevant to the various machine load activation times and starts (only for modular rack type).
• adjust the rinse flowrate cock ( just for atmospheric rack type).
• Save the parameters, datalog content and content of the statistics in a removable backup memory (for modular RT's only).
• Set the pressure sensors that detect the levels of the airgap, Duo rinse tank, wash tank and prewash tank.
• Carry out feed gear motor current setting.
WARNING:
After entering the SERVICE MENU switch the machine off and then on again to return to normal operation.
A4.1
PARAMETERS
show the first family of parameters.
A4.1.1
USER SETTINGS (ONLY FOR MODULAR RACK TYPE NO USA)
The USER SETTINGS family contains parameters for setting the user interface.
USER SETTINGS
Use the increase and decrease keys to select the other parameter families.
Press the accessory functions key (“D” - (Figure 1)) to display the SERVICE MENU again.
DOC. NO. 5956.573.04
P. 10 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Press the confirm key (“C” - (Figure 1)) to access the first parameter of the USER SETTINGS family.
USER SETTINGS
Language
ENGLISH
Press the accessory functions key (“D” - (Figure 1)) to display the USER SETTINGS family again.
Use the increase and decrease keys to select the other parameters of the USER SETTINGS family.
Press the confirm key to edit the selected parameter; the selection arrow moves from the parameter name to the parameter value.
USER SETTINGS
Language
ENGLISH
Use the increase and decrease keys to modify the parameter value. Press the confirm key to save the new set value. Press the accessory functions key to exit without saving the new setting.
The USER SETTINGS family parameters are described below:
Parameter name
Language
Contrast
Family
Nr.
0
0
Parameter
Nr.
0
1
Parameter description
Allows setting of required language
Allows setting of screen contrast
Unit of measure
-
-
Min
-
0
Max
-
5
Factory setting
English
3
Available languages: ENGLISH, ITALIAN, GERMAN, FRENCH, SPANISH, PORTUGUESE, DUTCH, DAN-
ISH, NORWEGIAN, SWEDISH, FINNISH, GREEK, RUSSIAN, ESTONIAN, LATVIAN, LITHUANIAN,
POLISH, CZECH, HUNGARIAN, SLOVAK, SLOVENIAN, TURKISH.
A4.1.2
GENERIC FUNC.
The GENERIC FUNC. family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The GENERIC FUNC. family contains parameters that identify several general machine characteristics.
MODULAR RACK TYPE
COMPACT RACK TYPE AND USA MODULAR
GENERIC FUNC.
DOC. NO. 5956.573.04
P. 11 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
The GENERIC FUNC. family parameters are described below:
Modular parameter
Compact paramet er
SP1 rd1
SP2 rd2
Family
Nr.
Parame ter Nr.
Parameter description Unit of meas ure
-
Appl. type
Appl. direct.
Speed nr.
1
Wash time sp 1
Speed nr.
2
Wash time sp 2
APt
Ad
1
1
1
1
1
1
0
1
2
3
4
5
Machine type for modular rack type:
0/Ws Ri : 2 modules rinse and wash.
1/Pw Ws Ri : 3 modules rinse, wash and prewash.
2/Pw Ws Ri Dt: 4 modules rinse, wash, prewash and DT.
3/Ws Ri Dt: 3 modules rinse, wash and DT.
Machine type for compact rack type:
4: Compact pressurized plumbing circuit
5: Compact atmospheric plumbing circuit
6: Compact pressurized plumbing circuit with dt
7: Compact atmospheric plumbing circuit with dt
8: Compact pressurized plumbing circuit with prewash
9: Compact atmospheric plumbing circuit with prewash
10: Compact pressurized plumbing circuit with prewash and dt
11: Compact atmospheric plumbing circuit with prewash and dt
12: Compact Usa
13: Compact Usa with DT
14: Compact Usa with prewash
15: Compact Usa with prewash and DT
Rack pulling direction (meaningful parameter only for Modular Rack Type NO USA):
1/LEFT: left rack insertion.
0/RIGHT: right rack insertion.
Indicates gear motor operation frequency at speed
1.
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 is set
Indicates gear motor operation frequency at speed
2.
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 is set.
-
-
Hz sec
Hz sec
(*) For the other equipment families, see par. B PROGRAMMING SHEETS
Min
-
-
Max
-
-
RIGHT
(0)
LEFT
(1)
15
0
15
0
100
127
100
250
Factory setting [for
WTM165 (*)]
Ri Ws
(0)
RIGHT
(0)
27
(**)
110
51
(**)
58
(**)
(***)
Modular machine type
Racks/h Speed nr. 1
Speed nr. 1
Racks/h Speed nr. 2
Speed nr. 2
WTM140
80
25
140
45
WTM165
90
27
165
51
WTM180
110
35
180
58
WTM200
130
40
200
63
WTM250
160
53
250
83
WTM300
180
60
300
100
WT82
250
70
350
100
WT105
250
70
350
100
(**)
(***)
Compact machine type
Racks/h Speed nr. 1
Speed nr. 1
Racks/h Speed nr. 2
Speed nr. 2
RTCS90 /
WTCS90
90
27
90
27
RTCS140 /
WTCS140
90
27
140
45
RTCS180 /
WTCS180
120
35
180
58
RTCS250 /
WTCS250
180
57
250
80
(***) To comply with Standard DIN 10510 it is advisable to use speed nr. 1
WT44
100
31
200
63
WT66
100
31
200
63
DOC. NO. 5956.573.04
P. 12 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Modular parameter
Compact parameter
Family
Nr.
Clean duration
dCd
1
Param eter
Nr.
11
Drain enable
drE
1 16
Parameter description
Duration of wash phase during self-clean cycle.
The self-cleaning cycle is carried out with the following steps:
1.
complete emptying of tanks;
2.
partial filling of tanks;
3.
3 washes of duration set in the “Clean duration” parameter, separated by two 5-second pauses;
4.
complete emptying of tanks and air gap.
Enabling of drain and self-clean cycles:
0: All the drain and self-clean cycles are disabled.
1: Enables the drain cycle of all tanks in the equipment.
5: Enables the drain cycle of all tanks in the equipment and only the drain cycle for the wash tank.
7: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank and only the drain cycle for the prewash tank.
13: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank and only the drain cycle for the DUO rinse tank.
15: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the prewash tank and only the drain cycle for the DUO rinse tank.
21: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank and the drain cycle for the air gap.
23: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the prewash tank and the drain cycle for the air gap.
29: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the DUO rinse tank and the drain cycle for the air gap.
31: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the prewash tank, only the drain cycle for the DUO rinse tank and the drain cycle for the air gap.
33: Enables the drain cycle of all tanks in the equipment and the self-clean cycle.
37: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank and the self-clean cycle.
39: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the prewash tank and the self-clean cycle.
45: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the DUO rinse tank and the selfclean cycle.
47: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the prewash tank, only the drain cycle for the DUO rinse tank and the self-clean cycle.
49: Enables the drain cycle of all tanks in the equipment and the self-clean cycle and the drain cycle for the air gap.
53: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank and the self-clean cycle and the drain cycle for the air gap.
55: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the prewash tank, the selfclean cycle and the drain cycle for the air gap.
61: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the DUO rinse tank, the self-clean cycle and the drain cycle for the air gap.
63: Enables the drain cycle of all tanks in the equipment, only the drain cycle for the wash tank, only the drain cycle for the prewash tank, only the drain cycle for the DUO rinse tank, the self-clean cycle and the drain cycle for the air gap.
Unit of meas ure
sec
Min
0
0
Max
100
Factory setting [for
WTM165 (*)]
15
63 61
DOC. NO. 5956.573.04
P. 13 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
.
Modular parameter
Compact parameter
Family
Nr.
Para meter
Nr.
Heat two comm.
Heating manage
H2C
B_t
1
1
18
19
Parameter description
Modular Rack Type:
Wash tank heating element management mode; if set on “Yes” (1) the two heating elements are managed by two separate controls, otherwise they are managed by a single control (See
Figure 8 Scheme for “Heat two comm.” parameter and “Heating manage”
parameter (only for Modular Rack Type)).
Compact Rack Type: the mode “1” is not available on compact machines.
Machine heating power management.
Maximum power: the wash tank heating elements and the boiler heating elements can operate at the same time.
WARNING:
Check the electrical system and safety devices ahead of the equipment before setting “Max. power” mode
Unit of mea sure
-
-
Medium power: when the boiler heating elements are on, only one of the two wash tank heating elements can operate; during the warmup, the tank is heated first and then the boiler, whereas the boiler has priority during normal operation.
Minimum power: the wash tank heating elements cannot operate when the boiler heating elements are on; during the warmup, the tank is heated first and then the boiler, whereas the boiler has priority during normal operation (See
Figure 8 Scheme for “Heat two comm.” parameter and “Heating manage” parameter (only for Modular Rack Type) and
Figure 9 Scheme for “H2C” parameter and “b_t”
parameter (only for Compact Rack Type)).
Modular Rack Type:
0/“HIGH” = Maximum power
2/“MEDIUM” = Medium power
1/“LOW” = Minimum power
WARNING:
THIS CONFIGURATION CAN ONLY WORK
ON ELECTRICALLY ARRANGED MACHINES
AND THE “Heat two comm.” PARAMETER
MUST BE SET ON “Yes”.
The machines electrically arranged to operate in
“MEDIUM” mode are the WTM165, WTM200, WT82 and WT105
models.
Compact Rack Type:
“0” = Maximum power
“2” = Medium power
“1” = Minimum power
-
-
Min
No
(0)
0
0
Max
Yes
(1)
1
Factory setting
[for
WTM165
(*)]
Yes
(1)
HIGH
(0)
MEDIUM
(2)
MEDIUM
(2)
2
1
2
WARNING:
THIS CONFIGURATION “2” CAN NOT BE
IMPLEMENTED IN THE ACTUAL VERSIONS
OF COMPACT RACK TYPE.
DOC. NO. 5956.573.04
P. 14 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
HIGH
SINGLE
CONTACTOR
HARDWARE MACHINE
CONFIGURATION
DOUBLE
CONTACTOR
LOW
HIGH
MEDIUM
LOW
Heat two comm.
Heating manage
Figure 8 Scheme for “Heat two comm.” parameter and “Heating manage” parameter (only for Modular
Rack Type)
HARDWARE MACHINE
CONFIGURATION
SINGLE
CONTACTOR
0
1
(Maximum Power)
(Minimum Power)
H2C b_t
Figure 9 Scheme for “
H2C
” parameter and “
b_t
” parameter (only for Compact Rack Type)
DOC. NO. 5956.573.04
P. 15 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Modular parameter
Compact parameter
Boiler load tank
Sanit. enable
Heat pump
Fahrenhei t vis.
btF
SnE
HP
CF
Family
Nr.
1
1
1
1
Para meter
Nr.
20
22
23
28
Parameter description
Modular Rack Type:
Wash tank filling mode: the tank is filled by means of a dedicated solenoid valve.
Standard Compact Rack Type (old range):
Wash tank filling mode: the tank is filled by means of the rinse arms.
Short Compact Rack Type (new range):
Wash tank filling mode: the tank is filled by means of a dedicated solenoid valve.
Enables sanitization cycle (N.B.: A heating element must be installed in the prewash module if present).
The sanitising cycle consists of the following stages:
1.
compete emptying of the tanks and air gap;
2.
partial filling of the wash and prewash tanks;
3.
heating of wash tank water up to the temperature set in the “WASH MODULE” “Sanit temper” family parameter;
4.
WASH module sanitising; the duration of this stage is set in the “WASH MODULE” “wash san.duration” family parameter;
5.
wash tank emptying and prewash water heating up to the temperature set in the “PREWASH
MODULE” “Sanit temper” family parameter;
6.
PREWASH module sanitising; the duration of this stage is set in the “PREWASH MODULE”
“prewash san.duration” family parameter;
7.
prewash tank emptying.
Modular Rack Type:
- 0/ “No” sanitization cycle disable
- 1/“Yes” sanitization cycle enable.
Compact Rack Type:
“0” sanitization cycle disable
“1” sanitization cycle enable.
Enables heat pump management.
The heat pump contains 1050 g of R134a refrigerant liquid in its hydraulic circuit.
Modular Rack Type:
- 0/“No” heat pump management disable
- 1/“Yes” heat pump management enable.
Compact Rack Type:
“0” heat pump management disable
“1” heat pump management enable.
Unit of measure used in displaying temperatures; if set on “Yes” the temperature is displayed in degrees
Fahrenheit, otherwise in degrees Celsius.
Modular Rack Type:
“No” the temperature is displayed in degrees Celsius
“Yes” the temperature is displayed in degrees
Fahrenheit.
Compact Rack Type:
“0” the temperature is displayed in degrees Celsius
“1” the temperature is displayed in degrees
Fahrenheit.
Unit of measure
-
-
Min Max
No
(0)
0
Yes
(1)
1
Factory setting
[for
WTM165
(*)]
No
(0)
1
-
-
-
-
-
-
0
No
(0)
0
No
(0)
0
No
(0)
0
1
Yes
(1)
1
Yes
(1)
1
Yes
(1)
1
0
No
(0)
0
No
(0)
0
No
(0)
0
DOC. NO. 5956.573.04
P. 16 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Modular parameter
Compact parameter
Buzzer enabled.
Demo mode
Rinse autostart.
Max. motor curr.
*** buE dMo r_A
GCU ***
Family
Nr.
Para meter
Nr.
Parameter description
1
1
1
1
29
30
31
32
Enables machine buzzer.
Modular Rack Type:
- 0/“No” machine buzzer disable
- 1/“Yes” machine buzzer enable.
Compact Rack Type:
- “0” machine buzzer disable
- “1” machine buzzer enable.
Demo mode.
Modular Rack Type:
- 0/“No demo” normal operation.
- 1/“Demo mec” the users are not activated and the
inputs are not read, but communication between the
USER card and POWER cards is maintained .
- 2/“Demo user” the users are not activated, the inputs
are not read, the USER card doesn’t communicate
with the POWER cards.
Compact Rack Type:
- “0” normal dishwasher operation.
- “1” the users are not activated and the inputs are not
read, but communication between the USER card
and POWER cards is maintained .
- “2” not available on these models.
Indicates the type of command for the start of the rinse phase. It can be set to “Mechanical” (1) only if the special mechanical lever is present in the rinse zone.
**
Indicates the max. current deliverable to the gear motor by the inverter if the automatic gear motor current setting procedure was not carried out.
If the supplied current is higher than this value,the message “CROCKERY STUCK” appears on modular
Rack Type no USA and the message “
SEE ITEM
INSIDE
” on compact Rack Type e modulari USA.
Unit of measure
-
-
Min Max
No
(0)
0
Yes
(1)
1
Factory setting
[for
WTM165
(*)]
Yes
(1)
0
-
dec
Amp.
-
-
-
No demo
(0)
0
Sof twa re/0
0
-
Mec hani cal/
1
40
-
Software/0
35
(110Vac gearmotor)
0
(230Vac gearmotor)
Set default par.
spd
1 33 It allows all the parameters to be set to their default value. The set parameters are those of a WTM165 without DT.
The parameter set to “Yes” (1) automatically returns to “No” (0).
No/
0
Yes/
1
No/
0
(*) For the other equipment families, see par. B PROGRAMMING SHEETS.
** The table given below indicates the delay between transit of the rack on the autorinse lever and stopping of the rinse phase.
E.g. in a WTM165 working at high speed (165 racks/h) the rinse pump keeps operating for 11 seconds after the last rack has released the autorinse lever.
DOC. NO. 5956.573.04
P. 17 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM140
WTM165
WTM180
WTM200
WTM250
WTM300
WT82
WT105
Speed nr. 1
(Hz)
25
27
35
40
53
60
70
70
Capacity speed nr. 1 (racks/hour)
80
90
110
130
160
180
250
250
Delay speed nr. 1
(sec)
22
20
15
13
10
9
25
52
Speed nr. 2
(Hz)
45
51
59
63
83
100
100
100
Capacity speed nr. 2 (racks/hour)
140
165
180
200
250
300
350
350
In compact machines the rinse is active while the auto rinse lever is activated, without any delay.
Delay speed nr. 2
(sec)
12
11
9
9
6
5
17
38
*** Procedure for manually setting the “Max. motor curr.” parameter:
1. Wait until the machine, complete with tables, is ready for a wash cycle.
2. Start a wash cycle without putting racks in the machine and read the current absorbed by the gear
motor ( refer to par. A1 DISPLAY OF AUXILIARY VALUES).
3. Add 2 to the read value (e.g. if “Motor current” = 34 ---> 34+2=36 decA).
4. Set the “Max. motor curr.” parameter with the value thus obtained.
WARNING:
The Rack Type leaves the factory with the “Max motor curr.” parameter already set to the optimum value. Reset it only when replacing a PCB or the gear motor.
Modular parameter
Feeding delay
Pulse/ kWatt
Nsf settings
Mot. curr. margin
Compact parameter
FdI
EnP
(not significant for USA modular and compact machines) nSF
GCM
Family
Nr.
1
Para meter
Nr.
34
1 35
Parameter description
Indicates the time (min) from when the last basket is placed in the machine until the feed stops and the machine goes from
“WAITING FOR A BASKET” status to
“READY”.
Indicates the impulses per kilowatt/hour characterising the possible energy meter connected to the machine’s power cable.
Rating data of the energy measurer used.
Unit of measure
min
P/kWh
1
1
36
37
Sets the machine temperature in conformity with NSF regulations:
Wash tank temperature: 78°C
Wash tank temperature hysteresis: 0°C
Duo rinse temperature: 78°C
Duo rinse temperature hysteresis: 2°C
If the parameter is set to “No”, the default temperatures are set
Indicates the margin, expressed in tenths of amperes, between the current absorbed by the gearmotor at the various speeds and the value which, if reached, blocks the machine with display of the message “DISHES
JAMMED” on non-USA modular RT’s and
“SEE itEM inSIdE” on USA modular and compact RT’s.
Significant only if the gearmotor current was set with the “MOTOR ADJUST” procedure.
dec
Amp
Min
0
0
No
(0)
0
Max
60
Factory setting [for
WTM165 (*)]
25
999
Yes
(1)
5
0
No
(0)
2
DOC. NO. 5956.573.04
P. 18 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
A4.1.3
RINSE MODULE
The RINSE MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The RINSE MODULE family contains the parameters that identify the rinse module characteristics.
MODULAR RACK TYPE COMPACT RACK TYPE AND USA MODULAR
RINSE MODULE
The RINSE MODULE / rin family parameters are described below:
Modular parameter
Max. lev. airgap(*)
Max hist. airgap(*)
Work lev. airgap(*)
Max. lev. duo (**)
Dm max duo lev.
(**)
Max hist. duo (**)
Work lev. duo (**)
Boil. temp. start
Compact parameter
ASL
(*)
ASH
(*)
AnL
(*)
dSL
(**)
(meaningless for compact family) dSd
(**)
(meaningless for compact family) dSH
(**)
(meaningless for compact family) dnL
(**)
(meaningless for compact family) btS
Family
Nr.
2
2
2
2
2
2
2
2
Paramet er
Nr.
0
Parameter description
Max water level in air gap.
1
2
4
Hysteresis level relative to max level in the air gap.
Water level in the air gap enabling rinse pump operation.
Indicates the maximum level in the Duo rinse tank.
The filling stops when the water level reaches this value.
Unit of measure
mmH2O mmH2O mmH2O mmH2O
5
6
7
9
Meaningful only during ““Drain and clean” cycle.
Indicates the maximum level during “Drain and clean” cycle.
Indicates the hysteresis level relative to the maximum level in the Duo tank.
It is related to the “Max. lev. duo” and to the “Dm max duo lev.”.
Indicates the water level in the the Duo tank enabling the Duo heating element and the Duo pump operations.
mmH2O mmH2O mmH2O
°C / °F
Boiler temper.
Boil temp. wmup
Hist. boil temp.
Standby
Delta T
Active threshold
bot bti btH btd
ACt
(meaningless for compact
SHORT and
USA modular versions)
2
2
2
2
2
10
11
12
13
13
Boiler temperature set point at start of rinse phase; the initial overtemperature determined by this parameter ensures that the introduction of cold water in the boiler does not lower the rinse water temperature at the start of rinsing.
Boiler temperature set point.
Boiler warm-up temperature. During warm-up, the boiler temperature is brought to the parameter value, after which the boiler does not heat until the start of the wash stage.
It is advisable to set the Boil temp. warm-up parameter ( bti
) as follows:
- electric machines bti
= bot
- steam machines bti
< bot
.
Hysteresis temperature relative to boiler temperature set point.
When the machine is in standby mode, the water inside the boiler is kept at a temperature of bot-btd
(It is used to save energy when the machine is not in use; the boiler is kept at a lower temperature).
Indicates the temperature that determines the colour of the active LED (red/green).
If the rinse temperature stays below the set value for more than 2 minutes the LED turns red, otherwise it is green.
Setting the parameter to 0 disables the active LED
(it remains off).
°C / °F
°C / °F
°C / °F
°C / °F
°C / °F
Min
10
0
0
10/
50
10/
50
10/
50
0/0
0/0
0/32
30
0
0
30
100
80
100
100
Max Factory setting
80
30
40
55
100
80
50
99/
210
99/
210
99/
210
15/
27
70/
126
99/
210
45
10
30
92/198
86/187
86/187
0/0
5/9
75/167
DOC. NO. 5956.573.04
P. 19 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
First boil. temp.
First boil. hist.
Duo temper.
Hist. duo temp.
Drain del. airgap
Drain delay duo
Heat. tim. enable
Duo heat. unrel.
Airgap area
Pulse/lit rinse
Fbt
FbH dut dtH
Add ddd
HtE dHU
AAG
PLr
2
2
2
2
2
2
2
2
2
2
15
16
17
18
20
22
23
24
25
26
First boiler temperature set point.
( Significant only for USA machines with 2 boilers).
Set to 0°C (32°F) USA compact machines without boiler.
Hysteresis temperature relative to first boiler temperature set point.
( Significant only for USA machines with 2 boilers).
DUO rinse tank temperature set point.
Hysteresis temperature relative to DUO rinse tank temperature set point.
Time between reaching level “0” (air trap level) in the air gap and stop of rinse pump (during the draining cycle).
Time between reaching level “0” (air trap level) in the DUO rinse tank and closing of the drain solenoid valve; allows complete emptying of tank
(during the draining cycle).
Allows enabling/disabling of the boiler heating
Time out alarm ( alarm 15).
If the parameter is set to “No” (0), the alarm 15 is managed as a warning and does not shut down the machine even if the boiler never reaches the temperature set point.
Allows the Duo heating element operation to be freed from that of the other heating elements. If set to “Yes” (1) the Duo heating element can switch on even if the tank and boiler heating elements are on.
WARNING:
Check the electrical system and the safety devices ahead of the equipment before setting “Yes”.
Defines the base area of the airgap. This value is used in the “Rinse control” procedure.
Indicates the impulses per litre characterising the possible flow meter connected to the rinse module feed.
Rating of the flow meter used.
°C / °F
°C / °F
°C / °F
°C / °F sec sec
-
cmq
P/Lit
0/32 99/
210
0/0
5/41
0/0
0
15/
27
95/
203
50/
90
200
0 200
No/
0
Yes/
1
No/
0
Yes/
1
500
0
999
999
(*) The difference between the max. water level and the hysteresis level must be higher than the work hysteresis airgap.
Max. lev. airgap - Max. hist. airgap Work hist. airgap
ASL
-
ASH
>
AnL
(**) The difference between the max. water level and the hysteresis level must be higher than the working level:
Max. lev. duo - Max. hist. duo > Work lev. duo
dSL
-
dSH
>
dnL
(**) The difference between the max. water level during drain cycle and the hysteresis level must be higher than the working level:
Dm max duo lev. - Max. hist. duo > Work lev. duo
dSd
-
dSH
>
dnL
59/138
0/0
70/158
5/9
32
30
Yes/
1
No/
0
700
0
WORK STAGES
Rack removal wait
Warmup stage in progress
Machine ready for wash
Wash in progress
Rack wait
Cycle unload/unload & cleaning ready for execution
Cycle unload/unload & cleaning in progress
Cycle unload/unload & cleaning finished
SET POINT BOILER
"Boiler temp."
"Boil temp. Wmup"
"Boiler temp." - "Standby Delta T"
"Boiler temp." ("Start Boil. Temp.” at start of rinse)
"Boiler temp."
"Boiler temp." - "Standby Delta T"
"Boiler temp." - "Standby Delta T"
"Boiler temp." - "Standby Delta T"
Table 1
Work stages/Boiler set point
A4.1.4
WASH MODULE
The WASH MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
DOC. NO. 5956.573.04
P. 20 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
The WASH MODULE family contains the parameters that identify the wash module characteristics.
MODULAR RACK TYPE COMPACT RACK TYPE AND USA MODULAR
WASH MODULE
The WASH MODULE / tub family parameters are described below:
Modular parameter
Compact parameter
Family
Nr.
Param eter
Nr.
Parameter description
Wash module
tty
3 0
Stanby level (**)
Run max level (**)
Drain max lev. (**)
Max lev. hister. (**)
Working level (**)
Tank temper.
Sanit. temper.
Histesys temp.
Max
Temp.
CU
Hist.
Temp.
CU
tSS
(**)
tSr
(**)
tSd
(**)
tSH
(**)
tnL
(**)
tut tSt ttH
StC
HtC
3
3
3
3
3
3
3
3
3
3
1
2
3
4
5
9
10
7
8
11
Unit of measure
Type of wash module
Modular Rack Type:
-0/ “1165” module from 1165 mm
-1/ “1490” module from 1490 mm.
Compact Rack Type:
- “2” Wash+Rinse module
Indicates the maximum level in the wash tank.
The filling stops when the water level reaches this level.
The value for the maximum level is modified from
“Standby level” to “Run max level” during washing phase in order to avoid water loss when the pumps stop.
Meaninful only during “Drain and clean” cycle.
Indicates the maximum level during “Drain and clean” cycle.
Indicates the hysteresis level relative to the maximum level in the wash tank. It is related to the “Standby level” to the “Run max level” and to the “Drain max lev.”.
Indicates the water level in the wash tank enabling the wash tank heating elements and the wash pumps operations.
Tank temperature set point.
Tank temperature set point during the sanitization phase (only on machines with sanitization).
Hysteresis temperature relative to tank temperature set point.
Max permissible temperature for the water leaving the CU to enable heat pump operation. If the water leaving the CU exceeds this temperature, the machine continues to work normally but the heat pump (if present) stops.
WARNING:
Do not modify this parameter unless expressly required by the factory.
-
mmH2O mmH2O mmH2O mmH2O mmH2O
°C / °F
°C / °F
°C / °F
°C / °F
Max permissible temperature for the water leaving the CU to enable heat pump operation: if the temperature of the water leaving the CU falls below “Max temp. CU - Hist. temp. CU”, the machine continues to work normally but the heat pump (if present) stops.
WARNING:
Do not modify this parameter unless expressly required by the factory.
°C / °F
Min
-
-
60
60
60
0
60
5/41
10/50
0/0
1/34
1/2
Max
-
Factory setting
[for
WTM165
(*)]
1490
-
400
400
400
80
400
2
205
90/194
90/194
66/151
75/167
50/90
90/194
2/4
50/122
50/90
170
190
30
90
20/46
DOC. NO. 5956.573.04
P. 21 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Temp.
Thresh.
CU
Wash san. duration
Fan delay start
Fan delay stop
Drain delay
Autom. drain del.
Water to drain
Condensin g unit
Wash temp. ready
Pulse/lit wash
Warning lev wash
ttC
Std
CGd
CSd dtd
Atd qtd
CUn ttr
PLt
Alt
3
3
3
3
3
3
3
3
3
3
3
12
13
14
15
17
18
19
20
21
22
23
Meaninful only for machines with heat pump.
Indicates the CU temperature when the washing tank heating elements stop.
This function is enabled only if the heat pump is installed and allows maintaining the CU temperature compatible with the heat pump features.
Duration of wash tank cleaning phase during a sanitization cycle.
The time between start of wash and start of CU fan ( Parameter not significant for Compact Rack
Type ).
The time between stop of wash phase and stop of CU fan ( Parameter not significant for
Compact Rack Type ).
Time between reaching level “0” (air trap level) in the tank and closing of the drain solenoid valve; allows complete emptying of wash tank
Time between two automatic water changes. If this parameter is set at zero the function is disabled.
Quantity of water to be drained with each automatic emptying.
CU presence.
Indicates the wash tank temperature that determines the end of warm-up.
Indicates the impulses per litre characterising the possible flow meter connected to the wash module feed.
Rating of the flow meter used.
Indicates the max. level possible in the wash tank before the start of an automatic draining cycle. To prevent water spilling from the door in case of clogging of the overflow due to dirt.
°C / °F sec sec sec sec min mmH2O
-
°C / °F
P/Lit mmH2O
20 / 68
0
0
0
0
0
0
No/0
5/41
0
180
70 /
158
250
200
200
200
250
100
Yes/1
90/194
999
400
48 / 118
60
0
20
30
120
25
(***)
Yes/1
64/147
0
270
(*) For the other equipment families, see par. .
(***)
WASH TANKS
Tank capacity
Water to drain (in litres/mm)
1165 mm /44”
100 l
0,32 l/mm
1490 mm
150 l
0,485 l/mm
(**) The difference between the max water level and the hysteresis level must be higher than the working level:
Stanby level - Max lev. hister > Working level
tSS - tSH
>
tnl
(**) The difference between the max water level during washing phase and the hysteresis level must be higher than the working level:
Run max level - Max lev. hyster. > Working level
tSr - tSH
>
tnl
(**) The difference between the max water level during drain cycle and the hysteresis level must be higher than the working level:
Drain max lev. - Max lev. hyster. > Working level
tSd - tSH
>
tnl
A4.1.5
PREWASH MODULE
The PREWASH MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The PREWASH MODULE family contains the parameters that identify the prewash module characteristics.
MODULAR RACK TYPE COMPACT RACK TYPE AND USA MODULAR
PREWASH MODULE
DOC. NO. 5956.573.04
P. 22 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
:
The PREWASH MODULE /
PrE family parameters are described below:
Modular parameter
Compact parameter
Family
Nr.
Param eter
Nr.
Parameter description Unit of measur e
Min Max Factory setting
[for
WTM200
(*)]
Prewash module
Stanby level
Run level
Drain max lev.
Max lev. hister.
Working level
Pty
SbL
PSS
PSd
PSH
PnL
(**)
(**)
(**)
(**)
(**)
Prt
PSt
PtH
SPd
APd qPd dPt
4
4
4
4
4
4
0
1
2
3
4
5
Type of prewash module
Modular Rack Type:
- 0/“1165-600” module from 1165 mm or from 600 mm
- 1/“1490” module from 1490 mm.
Compact Rack Type:
- “0” module from 1165 mm, from 600 mm, from 44” or from 22” “0” module from 1165 mm or from 600 mm
- “1” module from 1490 mm (meaningless for compact
RT).
“1” module from 1490 mm.
Indicates the maximum level in the prewash tank.
The filling stops when the water level reaches this value.
The value for the maximum level is modified from
“Stanby level” to “Run level” during prewashing phase in order to avoid water loss when the pumps stop.
Meaninful only during “Drain and clean” cycle.
Indicates the maximum level during “Drain and clean” cycle.
Indicates the hysteresis level relative to the maximum level in the prewash tank. It is related to the “Stanby level” , to the “Run level” and to the “Drain max lev.”.
Indicates the water level in the prewash tank enabling the prewash tank heating elements and the prewash pumps operations.
Tank temperature set point.
-
mmH2O mmH2O mmH2O mmH2O mmH2O
-
-
60
60
60
0
60
-
-
400
400
400
80
400
Tank temper.
Sanit. temper.
Histesys temp.
Prew. san. durat.
Drain delay
Autom. drain del.
Water to drain
Max temper. prew.
Pulse/lit prewash
Warning lev prew.
dPd
PLP
Alt
4
4
4
4
4
4
4
4
4
4
7
8
9
10
12
13
14
15
16
17
Tank temperature set point during sanitization phase
(only on machines with sanitization - N.B.: heating element must be installed in prewash module).
Hysteresis temperature relative to tank temperature set point.
Duration of wash tank cleaning phase during a sanitization cycle.
Time between reaching level “0” (air trap level) in the tank and closing of the drain solenoid valve; allows complete emptying of tank.
Time between two automatic water changes. If this parameter is set at zero the function is disabled.
Quantity of water to be drained with each automatic emptying.
Max permissible temperature in prewash tank. If the tank temperature exceeds the set temperature, a quantity of water equal to the quantity set by means of the "Water to drain" parameter is drained.
If this parameter is set at zero the function is disabled.
Indicates the impulses per litre characterising the possible flow meter connected to the prewash module feed.
The rating plate data of the flow meter used.
Indicates the max. level allowed in the wash tank before the start of an automatic draining cycle. To prevent water spilling from the door in case of clogging of the overflow due to dirt.
°C / °F
°C / °F
°C / °F sec sec min mmH2O
°C / °F
P/Lit mmH2O
5/
41
10/
50
1/2
0
0
0
0
0/
32
0
180
90/
194
90/
194
50/90
250
200
250
50
99/
210
999
400
(**) The difference between the max water level and the hysteresis level must be higher than the working level:
Stanby level - Max lev. hister > Working level
SbL - PSH
>
Pnl
(**) The difference between the max water level during washing phase and the hysteresis level must be higher than the working level:
Run level - Max lev. hister > Working level
PSS - PSH
>
Pnl
(**) The difference between the max water level during drain cycle and the hysteresis level must be higher than the working level:
Drain max level - Max lev. hister > Working level
PSd - PSH
>
Pnl
1165-600
0
220
180
190
30
90
10/50
75/167
5/9
60
30
50
10
(****)
40/104
0
270
DOC. NO. 5956.573.04
P. 23 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
(*) For the other equipment families, see par. .
(****)
PREWASH TANKS
Tank capacity
Water to drain (in litres/mm)
600 mm /22”
45 l
0,136 l/mm
1165 mm /44”
100 l
0,32 l/mm
1490 mm
150 l
0,485 l/mm
A4.1.6
DT MODULE
The DT MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The DT MODULE family contains the parameters that identify the drying zone (DT) characteristics.
MODULAR RACK TYPE COMPACT RACK TYPE AND USA MODULAR
DT MODULE
The DT MODULE / dt family parameters are described below:
Modular paramet er
Dt temper.
Dt hist. temp.
Dt fan delay
Dt type.
Compact parameter
dtt dtH
Afd d_t
Family
Nr.
5
5
5
5
Paramet er
Nr.
0
1
3
4
Parameter description
Drying tunnel temperature set point.
Hysteresis temperature relative to the drying tunnel temperature set point.
Time between stop of DT heating element and stop of DT fan. This parameter ensures a correct cooling for the DT heating element.
Indicates the type of DT installed.
Unit of measure
°C / °F
°C / °F sec
-
Min
10/
50
0/0
0
Max
90/
194
50/
90
250
Factory setting
70/158
3/5
120
Stan dard
/0
New type/
1
Standard/
0
For setting the Standard/0 or New type/1 parameter refer to the tables listed below.
DOC. NO. 5956.573.04
P. 24 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
534123
534261
534263
534265
534267
534269
534271
534273
534275
534124
534126
534128
534130
534132
534134
534125
534127
534129
534131
534133
534135
534264
534266
534268
534270
534272
534274
534101
534103
534105
534107
534109
534111
534113
534115
534117
534119
534121
MODULAR RACK TYPE (WTM / RTM)
The dryer tunnels for the Modular RT's cannot be installed on the Compact RT's (old range) or the Short Compacts (new range).
Factory code Factory model appropriate DT/HAB Dt type. (
d_t
)
534100 WTM140ERA
534102
534104
534106
534108
534110
WTM140ERB
WTM165ERA
WTM165ERB
WTM200ERA
WTM200ERB
D T 9 0 0 m m
8 6 4 5 0 0 A D T L E R / M D
Standard/0
534112
534114
534116
534118
534120
534122
534260
534262
WTM250ERA
WTM250ERB
WTM300ERA
WTM300ERB
WTM180ERA
WTM180ERB
RTM140ERA
RTM140ERB
D T 6 0 0 m m
8 6 4 5 1 0 A D T E R / M D
D T 9 0 °
8 6 4 5 1 2 A D T E R C 9 0 M D
WTM180ELB
RTM140ELA
RTM140ELB
RTM165ELA
RTM165ELB
RTM180ELA
RTM180ELB
RTM200ELA
RTM200ELB
WTM140SRA
WTM165SRA
WTM180SRA
WTM200SRA
WTM250SRA
WTM300SRA
WTM140SLA
WTM165SLA
WTM180SLA
WTM200SLA
WTM250SLA
WTM300SLA
RTM165ERA
RTM165ERB
RTM180ERA
RTM180ERB
RTM200ERA
RTM200ERB
WTM140ELA
WTM140ELB
WTM165ELA
WTM165ELB
WTM200ELA
WTM200ELB
WTM250ELA
WTM250ELB
WTM300ELA
WTM300ELB
WTM180ELA
D T 9 0 0 m m
8 6 4 5 0 1 A D T L E L / M D
D T 6 0 0 m m
8 6 4 5 1 1 A D T E L / M D
D T 9 0 °
8 6 4 5 1 3 A D T E L C 9 0 M D
D T 9 0 0 m m
8 6 4 5 1 4 A D T L S R / M D
D T 9 0 0 m m
8 6 4 5 1 5 A D T L S L / M D
Standard/0
Standard/0
Standard/0
Standard/0
DOC. NO. 5956.573.04
P. 25 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
534352
534354
534301
534303
534305
534307
534309
534311
534313
534315
534317
534319
534321
534323
534325
534327
534341
534343
534345
534347
534349
534351
534353
534355
SHORT COMPACT RACK TYPE (WTCS/ RTCS)
The dryer tunnels for the Short Compacts (new range) cannot be installed on the Modular RT's or the Compact RT's (old range).
Factory code Factory model appropriate DT/HAB Dt type. (d_t)
534300
534302
534304
WTCS90ERB
WTCS140ERA
WTCS140ERB
534306
534308
534310
534312
534314
534316
534318
534320
534322
534324
534326
534340
534342
534344
534346
534348
534350
WTCS180ERA
WTCS180ERB
WTCS250ERA
WTCS250ERB
RTCS90ERB
RTCS140ERA
RTCS140ERB
RTCS180ERA
RTCS180ERB
RTCS250ERA
RTCS250ERB
WTCS140RAO
WTCS140RBO
WTCS180RAO
WTCS180RBO
RTCS140RAO
RTCS140RBO
D T 9 0 0 m m
8 6 4 5 1 6 A D T R T E R 9
D T 6 0 0 m m
8 6 4 5 1 8 A D T R T E R 6
D T 9 0 °
8 6 4 5 2 0 A D T R T E R C
H A B 6 0 0 m m
8 6 4 5 0 6 H A B R T E R
New type/1
RTCS180RAO
RTCS180RBO
WTCS90ELB
WTCS140ELA
WTCS140ELB
WTCS180ELA
WTCS180ELB
WTCS250ELA
WTCS250ELB
RTCS90ELB
RTCS140ELA
RTCS140ELB
RTCS180ELA
RTCS180ELB
RTCS250ELA
RTCS250ELB
WTCS140LAO
WTCS140LBO
WTCS180LAO
WTCS180LBO
RTCS140LAO
RTCS140LBO
RTCS180LAO
RTCS180LBO
D T 9 0 0 m m
8 6 4 5 1 7 A D T R T E L 9
D T 6 0 0 m m
8 6 4 5 1 9 A D T R T E L 6
D T 9 0 °
8 6 4 5 2 1 A D T R T E L C
H A B 6 0 0 m m
8 6 4 5 0 7 H A B R T E L
New type/1
A4.1.7
HACCP
The HACCP family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
DOC. NO. 5956.573.04
P. 26 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
The HACCP family contains the parameters that identify the HACCP connection characteristics.
MODULAR RACK TYPE COMPACT RACK TYPE
HACCP
The HACCP /
HAC family parameters are described below:
Modular paramet er
Compact parameter
Adr
IrA
Hbr
Ibr
IrE
Family
Nr.
Paramet er
Nr.
Parameter description
Specific address of equipment in an IrDa communication network.
Indicates the communication speed of the equipment in an HACCP network.
Indicates the communication speed of the equipment in an IrDa communication network.
Parameter not used
Unit of meas ure
-
HACCP address
IR
Address
HACCP baud rate
IR baud rate
Enable
IR
6
6
6
6
6
0
1
2
3
4
Specific address of equipment in an HACCP network.
-
-
-
-
A4.1.8
RATING PLATE (ONLY FOR MODULAR RACK TYPE NON USA)
The RATING PLATE family contains the parameters that identify the machine rating data.
Min
0
0
1200/
0
1200/
0
0
Max
254
254
192
00/4
192
00/4
1
Facto ry settin g
1
1
9600/
3
9600/
3
0
RATING PLATE
The RATING PLATE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family except for the "STRING" parameters given in the following table.
After a “STRING” is displayed
RATING PLATE
P.N.C.
0000000000000 the parameter can be edited by pressing the confirm key; the selection arrow moves from the parameter name to the parameter value.
RATING PLATE
P.N.C.
0000000000000
DOC. NO. 5956.573.04
P. 27 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Use the increase and decrease keys to move the cursor until it is under the digit to be modified. Press the confirm key to modify the selected digit.
RATING PLATE
P.N.C.
0000000000000
The digit flashes and the value of the digit selected can be modified by using the increase and decrease keys.
Press the confirm key to save the new value. Press the accessory functions key to exit without saving.
When all the digits have been modified as required, press the accessory functions key to return to parameter selection mode.
The RATING PLATE family parameters are described below:
Parameter name
P.N.C.
Serial number
Model
Constr. year
Prod. site
Inst. power
Voltage supply
Frequency
Max. current
MCA
MOP
Prot. degree
Inst. day
Inst. month
Inst. year
Family
Nr.
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
Para meter
Nr.
0
1
6
7
2
3
4
5
8
9
10
11
12
13
14
Parameter description
Product Number Code
Serial number
Factory Model
Year of construction
Production site (6 = Washing)
Installed power
Power supply voltage
Frequency
Absorbed current
MCA (Minimum supply Circuit Ampacity)
[for USA versions only]
MOP (Maximum Overcurrent Protection)
[for USA versions only]
Protection rating
Installation day (*****)
Installation month (*****)
Installation year (*****)
Unit of measu re
-
-
Min Max Factory setting
-
-
-
-
-
-
-
-
kW
F
Hz
A
A
A
-
-
-
-
-
-
-
-
0
50
6
-
-
-
-
-
-
-
-
-
10
60
32
-
-
-
-
-
-
-
-
-
6
50
6
-
-
IPX5
-
-
-
Example
534104 00
54600001
WTM165ERA
+DT
2007
6
42,3 KW
AC 400 V 3P N
50 Hz
65A
-----
-----
IPX5
20
06
07
“STRING” parameter
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
(*****) The installer must set the day, month and year of installation.
A4.2
DATALOG (ONLY FOR MODULAR RACK TYPE NON USA)
Accessing the "DATALOG" mode allows a number of events that occurred in the machine to be displayed.
In addition to the event, the screen also shows the time the event began and ended, as well as other information whose significance depends on the type of event recorded.
Every event is characterised by a START date and time and a STOP date and time.
The event STOP can be recorded when its cause is no longer present (e.g. a temperature exceeding the permissible upper limit and then coming within the correct range),
EVENT DATALOG
34 WASH OVERTEMP.
TYPE DD-MM-YY HH:HH VALUE
START 10-10-05 14:10 80 °C
WASH OVERTEMP.
STOP 10-10-05 14:15 or when the machine is switched off following shutdown by the user (POWER OFF) or no power (POWER
FAIL). In the latter case, event STOP is described with the indication POWER OFF or POWER FAIL.
DOC. NO. 5956.573.04
P. 28 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
EVENT DATALOG
34 WASH OVERTEMP.
TYPE DD-MM-YY HH:HH VALUE
START 10-10-05 14:10 80 °C
POWER OFF
STOP 10-10-05 14:15
If accessing the display of an event that began after the last machine start and which has not ended because its cause is still present, closing of the event is not displayed.
EVENT DATALOG
34 WASH OVERTEMP.
TYPE DD-MM-YY HH:HH VALUE
START 10-10-05 14:10 80 °C
STOP ------------ --:-- -------
DOC. NO. 5956.573.04
P. 29 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
List of events documented by the DATALOG:
Event description Event number
1
2
5
6
3
4
Event name
BOIL. TEMP. HIGH
DUO TEMP. HIGH
WASH. TEMP. HIGH
PREW. TEMP. HIGH
DT TEMP. HIGH
BOIL. TEMP. LOW
7
8
9
13
14
15
22
23
20
21
11
12
18
19
16
17
27
30
24
25
31
32
33
DUO TEMP. LOW
WASH TEMP. LOW
DT TEMP. LOW
AIRG. FILL. TOUT
AIRG. LEV. FAULT
DUO FILL. TOUT
DUO LEV. FAULT
BOIL. HEAT. TOUT
BOILER OVERTEMP.
BOILER NTC SHORT
BOILER NTC OPEN
DUO HEAT. TOUT
DUO OVERTEMP.
DUO NTC SHORT
DUO NTC OPEN
RIN. PUMP THERM.
DUO PUMP THERM.
DRAIN DUO TOUT
INVERTER ERROR
DRAIN AIRG TOUT
WASH FILL. TOUT
WASH LEV. FAULT
WASH HEAT. TOUT
Event value (VALUE)
The boiler temperature has exceeded the temperature set point by 7 °C/13 °F.
The duo rinse temperature has exceeded the temperature set point by 8 °C/14 °F.
The wash tank temperature has exceeded the temperature set point by 8 °C/14 °F.
The prewash tank temperature has exceeded the temperature set point by 35 °C/63 °F.
The dry tunnel temperature has exceeded the temperature set point by 15 °C/27 °F.
During the wash phase the boiler temperature has decreased by more than 12 °C/25 °F with respect to the permissible min.
value (– hysteresis temperature set point).
During the wash phase the duo rinse temperature has decreased by more than 15 °C/27 °F with respect to the permissible min.
value (–hysteresis temperature set point).
During the wash phase the wash tank temperature has decreased by more than 15 °C/27 °F with respect to the permissible min. value (–hysteresis temperature set point).
During the wash phase the dry tunnel temperature has decreased by more than 15 °C/27 °F with respect to the permissible min. value (–hysteresis temperature set point).
Alarm number 11 has occurred:
The Air Gap was not completely filled within the max. filling time.
Alarm number 12 has occurred:
The pressure sensor on the rinse module electronic board does not work correctly.
Alarm number 13 has occurred:
The Duo-rinse tank was not completely filled within the max.
filling time.
Alarm number 14 has occurred:
The pressure sensor on the Duo-rinse tank does not work correctly.
Alarm number 15 has occurred:
The required temperature was not reached in the boiler within the max. heating time.
Alarm number 16 has occurred:
The water temperature in the boiler is too high
Alarm number 17 has occurred:
The boiler temperature sensor is short circuited.
Alarm number 18 has occurred:
The boiler temperature sensor is open.
Alarm number 19 has occurred:
The required temperature was not reached in the Duo-rinse tank within the max. heating time.
Alarm number 20 has occurred:
The water temperature in the Duo-rinse tank is too high.
Alarm number 21 has occurred:
The Duo-rinse tank temperature sensor is short circuited.
Alarm number 22 has occurred:
The Duo-rinse tank temperature sensor is open.
Alarm number 23 has occurred:
SHORT COMPACT AND MODULAR: The rinse pump thermal protector has tripped.
USA COMPACT: the rinse pump, wash pump or CU thermal protector has tripped.
Alarm number 24 has occurred:
The Duo-rinse pump thermal protector has tripped.
Alarm number 25 has occurred:
The Duo-rinse tank was not completely emptied within the max.
emptying time.
Alarm number 27 has occurred:
The motor control inverter has generated an error.
Alarm number 30 has occurred:
The Air gap was not completely emptied within the max.
emptying time.
Alarm number 31 has occurred:
The wash tank was not completely filled within the max. filling time.
Alarm number 32 has occurred:
The pressure sensor on the wash tank does not work correctly.
Alarm number 33 has occurred:
The required temperature in the wash tank was not reached within the max. heating time.
Indicates the boiler temperature at the time of event recording.
Indicates the duo rinse temperature at the time of event recording.
Indicates the wash tank temperature at the time of event recording.
Indicates the prewash temperature at the time of event recording.
Indicates the dry tunnel temperature at the time of event recording.
Indicates the boiler temperature at the time of event recording.
Indicates the duo rinse temperature at the time of event recording.
Indicates the wash tank temperature at the time of event recording.
Indicates the dry tunnel temperature at the time of event recording.
Indicates the air gap level at the time of event recording.
Indicates the air gap level at the time of event recording.
Indicates the duo rinse level at the time of event recording.
Indicates the duo rinse level at the time of event recording.
Indicates the boiler temperature at the time of event recording.
Indicates the boiler temperature at the time of event recording.
Not significant
Not significant
Indicates the duo rinse temperature at the time of event recording.
Indicates the duo rinse temperature at the time of event recording.
Not significant
Not significant
Not significant
Not significant
Indicates the duo rinse level at the time of event recording.
Indicates the selected speed at the time of event recording.
Indicates the airgap level at the time of event recording.
Indicates the wash tank level at the time of event recording.
Indicates the wash tank level at the time of event recording.
Indicates the wash tank temperature at the time of event recording.
DOC. NO. 5956.573.04
P. 30 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
56
57
54
55
58
49
50
51
46
47
48
Event number
34
35
36
37
38
39
40
42
43
44
45
52
53
Event name
WASH OVERTEMP.
WASH NTC SHORT
WASH NTC OPEN
WASH PUMP1 THER.
WASH PUMP2 THER.
CU FAN THER.
DRAIN WASH TOUT
AIRGAP LEV. LOW
DUO LEV. LOW
WASH LEV. LOW
PREWASH LEV.
LOW
POWER ON
FORCED WASH
EMERGENCY
SWITCH
PARAMETER MODE
PARAMETER
MODIF.
PREW. FILL. TOUT
PREW. LEV. FAULT
PREW. HEAT. TOUT
PREW. OVERTEMP.
PREW. NTC SHORT
PREW. NTC OPEN
PREW. PUMP THER.
DRAIN PREW. TOUT
Event description
Alarm number 34 has occurred:
The water temperature in the wash tank is too high.
Alarm number 35 has occurred:
The wash tank temperature sensor is short circuited.
Alarm number 36 has occurred:
The wash tank temperature sensor is open.
Alarm number 37 has occurred:
The upper wash pump thermal protector has tripped.
(short compact and modular machines only)
Alarm number 38 has occurred:
The lower wash pump thermal protector has tripped.
(modular machines only)
Alarm number 39 has occurred:
The CU (condensing unit) fan thermal protector has tripped.
(short compact and modular machines only)
Alarm number 40 has occurred:
The wash tank was not completely emptied within the max.
emptying time.
The air gap tank water level has fallen by more than 10 mm with respect to the permissible min. level (–hysteresis set point level).
The duo rinse tank water level has fallen by more than 10 mm with respect to the permissible min. level (–hysteresis set point level).
The wash tank water level has fallen by more than 20 mm with respect to the permissible min. level (–hysteresis set point level).
The prewash tank water level has fallen by more than 20 mm with respect to the permissible min. level (–hysteresis set point level).
Records appliance activation.
A wash start has been forced.
Event value (VALUE)
Indicates the wash tank temperature at the time of event recording.
Not significant
Not significant
Not significant
Not significant
Not significant
Indicates the wash tank level at the time of event recording.
Indicates the air gap level at the time of event recording.
Indicates the duo rinse level at the time of event recording.
Indicates the wash tank level at the time of event recording.
Indicates the prewash tank level at the time of event recording.
Not significant
Indicates the boiler temperature at the time of event recording.
Not significant The emergency mushroom has been pressed.
Parameter mode has been accessed.
A parameter has been modified.
Not significant
Indicates the modified family and parameter number.
Indicates the prewash tank level at the time of event recording.
Indicates the prewash tank level at the time of event recording.
Alarm number 51 has occurred:
The prewash tank was not completely filled within the max. filling time.
Alarm number 52 has occurred:
The pressure sensor on the prewash tank does not work correctly.
Alarm number 53 has occurred:
The required temperature in the prewash tank was not reached within the max. heating time.
Alarm number 54 has occurred:
The water temperature in the prewash tank is too high.
Alarm number 55 has occurred:
The prewash tank temperature sensor is short circuited.
Alarm number 56 has occurred:
The prewash tank temperature sensor is open.
Alarm number 57 has occurred:
The prewash pump thermal protector has tripped.
Alarm number 58 has occurred:
The prewash tank was not completely emptied within the max.
emptying time.
Indicates the prewash tank temperature at the time of event recording.
Indicates the prewash tank temperature at the time of event recording.
Not significant
Not significant
Not significant
Indicates the prewash tank level at the time of event recording.
DOC. NO. 5956.573.04
P. 31 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
85
86
89
83
84
90
72
73
74
75
76
Event number
60
61
62
63
64
65
66
71
77
78
79
80
81
82
Event name
CU NTC SHORT
CU NTC OPEN
HEAT PUMP FAULT
CU TEMP. HIGH
CU TEMP. LOW
LEV. LOW WASH
RINSE FLOW CTRL
DT HEAT. TOUT
DT OVERTEMP.
DT NTC SHORT
DT NTC OPEN
DT FAN THER.
MOT CURR OOR H.
MOT CURR OOR L.
HIGH MOT. CURR.
BOIL. USA T. HI.
BOIL. USA T. LO.
EN. PEAK CTRL.
BOIL. USA TOUT
BOIL. USA OVERT.
BOIL. USA NTC S.
BOIL. USA NTC O.
SEN. PRESS. ADJ
U.I. TEMP. HIGH
ECAP ERROR
Event description
The warning number 60 has occurred:
The CU temperature sensor is short circuited.
The warning number 61 has occurred:
The CU temperature sensor is open.
The warning number 62 has occurred:
Indicates that the heat pump has generated an error.
The CU temperature has exceeded by 8°C/14°F degrees the permissible max. value to ensure the correct operation of the heat pump.
During the wash phase the CU temperature has decreased by more than 10 °C/18 °F with respect to the permissible min. value
(–hysteresis temperature set point) to ensure the correct operation of the heat pump.
Washing has stopped due to a lowering of the levels
A calibration cycle for the rinse flow shutter has been started.
Alarm number 71 has occurred:
The required temperature in the drying tunnel was not reached within the max. heating time.
Alarm number 72 has occurred:
The temperature in the drying tunnel is too high.
Alarm number 73 has occurred: ( Up to version FW 1.52)
The drying tunnel temperature sensor is short circuited.
Alarm number 74 has occurred:
The drying tunnel temperature sensor is open.
Alarm number 75 has occurred:
The drying tunnel fan thermal protector has tripped.
Alarm number 76 has occurred:
The gear motor supplied current is higher than the maximum value allowed for the gear motor current.
Alarm number 77 has occurred:
The gear motor supplied current is lower than the minimum value allowed for the gear motor current.
Dishes are jammed.:
The gear motor supplied current is higher than the value set in the “Max motor curr.” parameter.
The first boiler temperature has exceeded the temperature set point by 7 °C/13 °F.
During the wash phase the first boiler temperature has decreased by more than 12 °C/25 °F with respect to the permissible min. value (– hysteresis temperature set point).
The “Energy peak control” input has been activated. All the heating elements of the machine remain off during activation of this input.
Alarm number 82 has occurred:
The required temperature was not reached in the first boiler within the max. heating time.
Alarm number 83 has occurred:
The water temperature in the first boiler is too high
Alarm number 84 has occurred:
The first boiler temperature sensor is short circuited.
Alarm number 85 has occurred:
The first boiler temperature sensor is open.
The pressure sensor setting procedure has been performed.
Alarm number 89 has occurred:
Temperature too high on User interface.
Alarm number 90 has occurred:
Communication problems between machine electronic boards.
Event value (VALUE)
Not significant
Not significant
Not significant
Indicates the CU temperature at the time of event recording.
Indicates the CU temperature at the time of event recording.
Indicates the air gap level at the time of event recording.
Whole part and fractional part of the flow measured.
Indicates the drying tunnel temperature at the time of event recording.
Indicates the drying tunnel temperature at the time of event recording.
Not significant
Not significant
Not significant
Not significant
Not significant
Indicates the supplied current to gear motor at the time of event recording.
Indicates the first boiler temperature at the time of event recording.
Indicates the first boiler temperature at the time of event recording.
Indicates the boiler temperature at the time of event recording.
Indicates the first boiler temperature at the time of event recording.
Indicates the first boiler temperature at the time of event recording.
Not significant
Not significant
Not significant
Indicates the User interface temperature at the time of event recording.
Indicates the module that generated a communication error between User interface and Mec:
1: rinse
2: wash
4: prewash
8: DT.
DOC. NO. 5956.573.04
P. 32 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
A4.3
INFO
firmware (FW) versions will be displayed.
MODULAR RACK TYPE COMPACT RACK TYPE OR USA MODULAR i
INFO
FW USER 16660200
FW LCD
FW RINSE
16660300
16360100
FW WASH 16360100
FW PREWASH 16360100
FW DT 16360100
USER
POWER
POWER
1.65
1.63
1.63
COMPACT
WASH + RINSE
USA MODULAR
RINSE
PREWASH or DT WASH
Modular Rack Type will show the USER INTERFACE board software version (FW USER e FW LCD) and the
POWER boards software versions (FW RINSE, FW WASH, FW PREWASH, FW DT), Compact Rack Type will show the USER INTERFACE board software version and the POWER board connected to the USER
INTERFACE software version.
Press the confirm key to return to the SERVICE MENU.
A4.4
STATISTICS (ONLY FOR MODULAR RACK TYPE NON USA)
display will show the statistics relevant to starts and activation times of the first electric user of the machine.
The table below describes all the codes (LOAD CODE) of the electric users in the machine. The display shows the minutes of activation and number of starts of the selected electric user starting from the machine installation date.
It also shows the number of starts (RESET ACT) of the selected electric user, counted from the date indicated opposite, which corresponds to the last reset.
STATISTICS
LOAD CODE 25
12000 MIN 100 ACT
RESET ACT DD-MM-YY HH:MM
2 10-10-05 14:25
.
In fact the number of starts counter for the selected electric user can be reset, by pressing the confirm key; in this way STATISTICS RESET mode is accessed.
STATISTICS RESET
LOAD CODE 25
12000 MIN 100 ACT
RESET ACT DD-MM-YY HH:MM
2 10-10-05 14:25
Press the confirm key again to reset the number of starts counter (RESET ACT).
The number of starts counter (RESET ACT) is reset and the date and time are saved.
If the last reset of the resettable counter (RESET ACT) occurred in the factory, the indication FAC appears next to the reset time.
Press the accessory functions key to exit STATISTICS RESET mode.
DOC. NO. 5956.573.04
P. 33 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
List of codes (LOAD CODE) of electric users in the machine:
28
29
30
31
24
25
26
27
32
33
34
20
21
22
23
16
17
18
19
12
13
14
15
8
9
10
11
LOAD CODE
1
2
3
6
7
4
5
Electric user description
Air gap filling solenoid valve (atmospheric machines)
Wash tank filling solenoid valve
Prewash tank filling solenoid valve
Boiler heating element
DUO heating element
Wash tank heating element
Wash tank second heating element (for machines with separately controlled tank heating elements only)
Prewash tank heating element
DT heating element
Upper wash pump
Lower wash pump (only modules with 2 wash pumps)
Upper prewash pump
Lower prewash pump (only modules with 2 wash pumps)
Rinse pump (atmospheric machines) rinse solenoid valve (pressurised machines)
DUO pump
CU fan
DT fan
DUO tank drain solenoid valve
Wash tank drain solenoid valve
Prewash tank drain solenoid valve
Wash pump impeller drain solenoid valve
Prewash pump impeller drain solenoid valve
Gear motor
Machine infeed motor-driven handling system start command
Machine outfeed motor-driven handling system start command
Machine infeed motor-driven handling system speed 2 start command
Machine infeed motor-driven handling system speed 2 start command
Heat Pump
Prewash module door opening
Wash module door opening
Rinse module door opening
DT module door opening
First boiler heating element (compact USA only)
Rinse aid dispenser (compact only)
A4.5
RINSE CONTROL ( JUST FOR ATMOSPHERIC RACK TYPE )
USA modular RT's) or when the message
rFC
appears on the display (USA modular or compact RT's), and the machine is going to start a rinse flow control cycle.
If there is a communication error between the rack type boards, the rinse flow control cycle cannot be carried out.
In this case the display will show:
RINSE FLOW CONTROL
RINSE FLOW CONTROL
NOT AVAILABLE
PRESS TO EXIT
DOC. NO. 5956.573.04
P. 34 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
If the communication is working correctly the dispaly informs the user that the machine is ready to start a rinse flow control cycle:
RINSE FLOW CONTROL
PRESS TO START
OR TO EXIT
Press the confirm key (“C” - (Figure 1)) and a control cycle is started:
RINSE FLOW CONTROL
RINSE FLOW CONTROL
IN PROGRESS
rfC pRG
Wait about 2 minutes, during which the machine performs a series of air gap filling solenoid valve and rinse pump activations, until the display will show the actual rinse flow:
RINSE FLOW CONTROL
5,0 Lit Min
PRESS
TO REPEAT OR TO EXIT
Compare the result obtained with the data given in the table below and if the flow is higher or lower than that indicated in the table, close or open the rinse flow regulating cock and repeat the control cycle until the optimum value is reached.
MACHINE TYPE
WTM140 / RTM140
WTM165 / RTM165
WTM180 / RTM180
WTM200 / RTM200
WTM250
WTM300
WTCS90 / RTCS90
WTCS140 / RTCS140
WTCS180 / RTCS180
WTCS250 / RTCS250
WT44
WT66
WT82
WT105
4.00
4.00
5.00
5.00
5.00
5.00
5.00
CORRECT FLOW (Lit/Min)
4.00 (5.00 with heat pump)
5.00
5.00
5.00
5.00
5.00
4.00
WARNING:
The Rack Type leaves the factory with the cock already adjusted in the optimum position.
WARNING:
The indication of rinse flowrate can be subject to an error of ± 0,3 litres/min.
DOC. NO. 5956.573.04
P. 35 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
A4.6
KEY MANAGEMENT ( JUST FOR MODULAR RACK TYPE )
Not available.
A4.7
SENSOR ADJUSTMENT
(Modular RT's no USA) or when the item
SAd
(Compact RT's or USA Modular) is displayed, to access the procedure for setting the machine pressure sensors.
The pressure sensors are fitted inside the electronic boards and read the levels of the Duo Rinse tank, wash tank, prewash tank and Airgap. It is advisable to carry out this procedure when replacing one of the following boards:
1 - Air gap level sensor card (Atmospheric RT's)
2 - Prewash module power board (Modular RT's)
2 - Wash module power board (Modular RT's)
4 - Rinse module power board (Modular RT's)
5 - Wash+Rinse module power board (Compact RT's)
WARNING:
All the tanks and the airgap must be completely emptied before carrying out the pressure sensor setting procedure.
WARNING:
The Rack Type leaves the factory with the pressure sensors already set to the optimum value.
Pressure sensor setting cannot be carried out if an error in communication between the Rack Type boards is in progress.
In this case the display will show:
PRES. SENS. SET-UP
PRES. SENS. SET-UP
NOT AVAILABLE
PRESS TO EXIT snS
AdJ n A
If the communication is working correctly the dispaly informs the user that the machine is ready for carrying out pressure sensor setting.
PRES. SENS. SET-UP
PRESS TO START
OR TO EXIT snS
AdJ rdY
DOC. NO. 5956.573.04
P. 36 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Press the confirm key - “C” (Figure 1) - and the setting cycle is started:
PRES. SENS. SET-UP
PRES. SENS. SET-UP
IN PROGRESS
snS
AdJ
PrG
Wait about 5 seconds, until the display will show:
PRES. SENS. SET-UP
DONE.
PRESS TO EXIT snS
AdJ
End
If the pressure sensor setting procedure is sterted without having previously emptied the tanks and air gap, the following message appears:
PRES. SENS. SET-UP
NOT EXECUTED
EMPTY BOTH TANKS AND AIRGAP
BEFORE MAKING SENSORS SET-UP
PRESS TO EXIT snS
AdJ n_d
A4.8
MOTOR ADJUSTMENT
USA Modular RT's) or when the item
GAD
(USA modular or compact RT's) appears on the display, and the gear motor current setting procedure is accessed.
WARNING:
The procedure is carried out after the installation of possible external tables and without placing racks in the machine.
In fact, the machine has an algorithm that controls the current absorbed by the feed gear motor and blocks the rack feed in case of mechanical jamming of racks or dishes. For the control of current to be carried out in the best of ways, setting of the gear motor current must carried out.
Gear motor setting cannot be carried out if an error in communication between the cards of the Rack Type is in progress. In this case the display shows:
GEARMOTOR SET-UP
GEARMOTOR SET-UP
NOT AVAILABLE
PRESS TO EXIT mot
AdJ n A
DOC. NO. 5956.573.04
P. 37 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
If the communication functions properly, the display shows the screen indicating that the machine is ready to carry out gear motor current setting.
GEARMOTOR SET-UP
PRESS TO START
OR TO EXIT mot
AdJ rdy
Press the confirm button “C” (Figure 1) to start the setting cycle.
WARNING:
If an alarm relevant to the gear motor (27-76-77) is in progress, a door is opened or the emergency stop is activated, gear motor setting is not carried out and the display shows.
GEARMOTOR SET-UP
NOT EXECUTED
PRESS TO EXIT mot
AdJ n_d
If none of the above events occurs, gear motor setting is carried out with the following criteria: the gear motor is made to operate at all the speeds provided for and the absorbed current is measured for each speed. The measured value is added to the value of the “Mot. curr. margin” (
GCM
) parameter
(“GENERIC FUNC” family) and the value thus obtained is saved and associated with the corresponding speed.
A table is thus created where each speed is associated with the corresponding max. current.
Example: if at 25 Hz the current measured = 33dec A and the “Mot. curr. margin” (
GCM
) parameter = 2decA, in normal operation at the speed of 25 Hz, the max. current that can be absorbed by the gear motor is 34 decA before shutting down the machine and showing the message:
) sEE itE ins
The value of theo “Mot. curr. margin” (
GCM
) parameter makes the machine more or less sensitive to possible jamming.
WARNING:
Do not modify the “Mot. curr. margin” (
GCM
) parameter unless expressly requested by the factory.
DOC. NO. 5956.573.04
P. 38 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
During the setting procedure, which lasts approx. 3 minutes, the display shows the following screen:
GEARMOTOR SET-UP
GEARMOTOR SET-UP
IN PROGRESS
Mot
AdJ prG
At the end of the current setting procedure the display shows the following screen:
GEARMOTOR SET-UP
DONE
PRESS TO EXIT
Mot
AdJ
EnD
It is advisable to carry out gear motor current setting upon machine installation and when one of the following components is replaced:
1. Gearmotor
2. Inverter
3. Rinse module (Modular) or Wash+Rinse module (Compact) power board
4. User interface board.
Setting is not carried out in the factory, since current absorption depends on the machine power supply voltage. When the machine leaves the factory, the current absorption limit is given by the value of the “Max motor curr.” (
GCU
) .
WARNING:
The parameter “Max motor curr.” (
GCU
) have following functions:
- if set to 0, the gear motor absorbed current control is disabled (even if it was the routine current setting);
- if the current setting procedure was not carried out, it represents the max. current threshold;
- if modified, it represents the max. current threshold even if the gear motor current setting procedure was carried out. To obtain the speed/ current correspondence again, it is necessary to launch the current setting procedure again.
When the gearmotor current is calibrated, the parameter GCU is automatically set to the maximum
value obtained in the calibration table.
B PROGRAMMING SHEETS
When installing a new user interface card in the equipment it must be configured according to the machine in which it is being installed. All the necessary information is given below; carry out the following steps:
1. With the machine code, find the Prog. number in the table given below
2. Follow the instructions on the PROG XXX sheets (next pages)
3. In case of card replacement, with the machine code find the corresponding LAYOUT number and refer to the LAYOUTS given in the section “LAYOUT OF CONNECTORS”
WARNING:
The parameters that must be configured are installation day, month and year (see par. A4.1.8 RATING
PLATE (ONLY FOR MODULAR RACK TYPE NON USA)), all the specific configuration parameters of
each equipment family (see par. B PROGRAMMING SHEETS) and the configuration parameters of the
“specific functions” (refer to par. B1 SPECIFIC FUNCTIONS).
DOC. NO. 5956.573.04
P. 39 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
534108
534109
534110
534111
534112
534113
534114
534115
534116
534117
534118
534119
534120
534092
534093
534094
534095
534096
534097
534100
534101
534102
534103
534104
534105
534106
534107
Factory Code
534070
534071
534072
534073
534074
534075
534076
534077
534090
534091
534135
534174
534175
534176
534177
534178
534179
534180
534181
534182
534183
534184
534185
534121
534122
534123
534124
534125
534126
534127
534128
534129
534130
534131
534132
534133
534134
DOC. NO. 5956.573.04
Prog
006
003
003
003
005
006
006
006
003
011
011
012
012
004
004
004
005
005
005
002
002
002
004
001
001
001
002
023
023
023
024
026
026
026
026
001
025
024
024
024
023
025
025
025
017
017
017
017
017
017
015
015
016
016
013
013
014
014
017
017
018
018
018
018
Layout
Table 2 Machine codes list and relative programming sheets
1 2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
14 15 16 17
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
10 11 12 13
10 11 12 13
10 11 12 13
10 11 12 13
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
1 2 3 (4)
1 2 3 (4)
11 13
11 13
11 13
11 13
11 13
11 13
11 13
11 13
10 11 12 13
10 11 12 13
10 11 12 13
10 11 12 13
14 15 16 17
14 15 16 17
14 15 16 17
14 15 16 17
14 15 16 17
14 15 16 17
14 15 16 17
5 8 14 15 16 17
5 8 14 15 16 17
5 8 14 15 16 17
5 8 14 15 16 17
Factory Model
WT44BL208
WT44BR208
WT44BL240
WT44BR240
WT44CL208
WT44CR208
WT44CL240
WT44CR240
WT66BL208
WT66BR208
WT66BL240
WT66BR240
WT66CL208
WT66CR208
WT66CL240
WT66CR240
WTM140ERA
WTM140ELA
WTM140ERB
WTM140ELB
WTM165ERA
WTM165ELA
WTM165ERB
WTM165ELB
WTM200ERA
WTM200ELA
WTM200ERB
WTM200ELB
WTM250ERA
WTM250ELA
WTM250ERB
WTM250ELB
WTM300ERA
WTM300ELA
WTM300ERB
WTM300ELB
WTM180ERA
WTM180ELA
WTM180ERB
WTM180ELB
WTM140SRA
WTM140SLA
WTM165SRA
WTM165SLA
WTM180SRA
WTM180SLA
WTM200SRA
WTM200SLA
WTM250SRA
WTM250SLA
WTM300SRA
WTM300SLA
WT82AL208
WT82AR208
WT82AL240
WT82AR240
WT82BL208
WT82BR208
WT82BL240
WT82BR240
WT105AL208
WT105AR208
WT105AL240
WT105AR240
534304
534305
534306
534307
534308
534309
534310
534311
534312
534313
534314
534315
534316
534266
534267
534268
534269
534270
534271
534272
534273
534274
534275
534300
534301
534302
534303
Factory Code
534186
534187
534188
534189
534260
534261
534262
534263
534264
534265
534343
534344
534345
534346
534347
534348
534349
534350
534351
534352
534353
534354
534355
534317
534318
534319
534320
534321
534322
534323
534324
534325
534326
534327
534340
534341
534342
Factory Model
WT105BL208
WT105BR208
WT105BL240
WT105BR240
RTM140ERA
RTM140ELA
RTM140ERB
RTM140ELB
RTM165ERA
RTM165ELA
RTM165ERB
RTM165ELB
RTM180ERA
RTM180ELA
RTM180ERB
RTM180ELB
RTM200ERA
RTM200ELA
RTM200ERB
RTM200ELB
WTCS90ERB
WTCS90ELB
WTCS140ERA
WTCS140ELA
WTCS140ERB
WTCS140ELB
WTCS180ERA
WTCS180ELA
WTCS180ERB
WTCS180ELB
WTCS250ERA
WTCS250ELA
WTCS250ERB
WTCS250ELB
RTCS90ERB
RTCS90ELB
RTCS140ERA
RTCS140ELA
RTCS140ERB
RTCS140ELB
RTCS180ERA
RTCS180ELA
RTCS180ERB
RTCS180ELB
RTCS250ERA
RTCS250ELA
RTCS250ERB
RTCS250ELB
WTCS140RAO
WTCS140LAO
WTCS140RBO
WTCS140LBO
WTCS180RAO
WTCS180LAO
WTCS180RBO
WTCS180LBO
RTCS140RAO
RTCS140LAO
RTCS140RBO
RTCS140LBO
RTCS180RAO
RTCS180LAO
RTCS180RBO
RTCS180LBO
Layout
6 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
5 8 14 15 16 17
5 8 14 15 16 17
5 8 14 15 16 17
5 8 14 15 16 17
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
1 2 3 (4)
6 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
6 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
5 6 8 9 (7)
Prog
007
008
008
008
010
010
010
007
008
009
009
009
009
008
009
009
009
009
010
007
008
008
008
004
004
004
007
018
018
018
002
003
003
003
003
004
001
002
002
002
018
001
001
001
028
028
028
028
027
027
027
027
027
027
010
010
010
010
027
027
028
028
028
028
P. 40 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM140/ RTM140
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 001
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Ws Ri / 0
Ws Ri Dt / 3
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
25
85
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
45
50
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
61
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
5
59
70
5
40
No / 0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1165 / 0
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank "warmup end" temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
PrE
PTy
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
Type of prewash module.
Standby level
Run level
SbL
Pss
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
Standard / 0
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 41 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM165/ RTM165
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 002
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Ws Ri / 0
Ws Ri Dt / 3
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
27
110
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
51
58
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
61
Yes / 1
Medium / 2
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
5
59
70
5
32
No / 0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 1
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank "warmup end" temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
PrE
PTy
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
Type of prewash module.
Standby level
Run level
SbL
Pss
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
Standard / 0
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 42 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM180/ RTM180
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 003
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Type of machine: Without Dt
Pw Ws Ri Dt / 2
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
35
108
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
58
59
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
5
59
70
5
32
No / 0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter PREWASH MODULE and set the following parameters.
1165 / 0
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter DT MODULE and set the following parameters.
1165-600 / 0
220
180
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter WASH MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 43 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM200/ RTM200
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 004
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Type of machine: Without Dt
Pw Ws Ri Dt / 2
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
40
105
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
63
65
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
Yes / 1
Medium / 2
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
5
59
70
5
32
No / 0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 0
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
220
180
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 44 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM250
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 005
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Type of machine: Without Dt
Pw Ws Ri Dt / 2
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
53
99
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
83
65
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
5
59
70
5
32
No / 0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 1
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
205
170
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 45 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM300
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 006
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Type of machine: Without Dt
Pw Ws Ri Dt / 2
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
60
100
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
100
60
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software/ 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
5
59
70
5
32
No / 0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 1
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1490 / 1
205
170
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 46 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTCS90/RTCS90
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 007
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
4
6
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
27
36
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
27
36
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
37
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
0
1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
0
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
Boiler temperature set point.
Boiler warm-up temperature.
5
59
70
5
40
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
66
2
Tank temperature set point.
Tank hysteresis temperature.
0
1
64
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
1
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 47 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTCS140/RTCS140
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 008
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
4
6
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
27
36
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
45
22
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
33 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
37
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
0
1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
0
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
Boiler temperature set point.
Boiler warm-up temperature.
5
59
70
5
40
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
66
2
Tank temperature set point.
Tank hysteresis temperature.
0
1
64
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
1
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 48 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTCS180/RTCS180
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 009
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
8
10
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
35
66
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
88 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
58
40
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
48 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
39
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
0
1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
0
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
Boiler temperature set point.
Boiler warm-up temperature.
5
59
70
5
40
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
66
2
Tank temperature set point.
Tank hysteresis temperature.
0
1
64
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
1
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 49 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTCS250/RTCS250
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 010
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
8
10
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
57
63
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
73 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
80
45
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
52 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
39
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
0
1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
0
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
Boiler temperature set point.
Boiler warm-up temperature.
5
59
70
5
32
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
66
2
Tank temperature set point.
Tank hysteresis temperature.
0
1
64
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
205
170
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
1
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 50 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM140S
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 011
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Ws Ri / 0
Ws Ri Dt / 3
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
25
85
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
45
50
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
61
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
82
Boiler temperature set point at start of rinse stage.
82
70
5
59
70
5
40
Yes / 1
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1165 / 0
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
220
180
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 51 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM165S
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 012
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Ws Ri / 0
Ws Ri Dt / 3
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
27
110
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
51
58
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
61
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
82
Boiler temperature set point at start of rinse stage.
82
70
5
59
70
5
32
Yes / 1
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 1
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
220
180
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 52 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM180S
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 013
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Pw Ws Ri Dt / 2
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
35
108
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
58
59
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
82
Boiler temperature set point at start of rinse stage.
82
70
5
59
70
5
32
Yes / 1
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1165 / 0
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
220
180
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 53 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM200S
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 014
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Pw Ws Ri Dt / 2
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
40
105
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
63
65
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
82
Boiler temperature set point at start of rinse stage.
82
70
5
59
70
5
32
Yes / 1
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 0
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
220
180
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 54 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM250S
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 015
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Pw Ws Ri Dt / 2
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
53
99
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
83
65
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
82
Boiler temperature set point at start of rinse stage.
82
70
5
59
70
5
32
Yes / 1
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 1
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1165-600 / 0
205
170
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 55 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM300S
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
Yes / 1
Sets all parameters to their default value.
PROG 016
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
Pw Ws Ri / 1
Pw Ws Ri Dt / 2
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
Left / 0
Right / 1
60
100
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
100
60
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
No / 0
High / 0
No / 0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Yes / 1
Celsius visualization
Fahrenheit visualization
Rinse autostart
r_A
GCU nSF
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
see par. A4.8
No / 0
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
82
Boiler temperature set point at start of rinse stage.
82
70
5
59
70
5
32
Yes / 1
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1490 / 1
66
2
No / 0
Yes / 1
64
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
1490 / 1
205
170
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Standard / 0
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 56 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
0
3
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
70
25
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
100
17
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
61
1
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius.
Celsius visualization.
Fahrenheit visualization r_A
GCU nSF
1
1 vedi par. A4.8
1
Indicates the type of rinse stage control.
Indicates the max. current deliverable to the gear motor by the inverter.
Tank temperature setting according to NSF standards.
Rinse autostart
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
198
Boiler temperature set point at start of rinse stage.
187
187
9
138
172
4
32
0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1
172
0
0
1
172
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
PrE
PTy
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
Standby level
Run level
SbL
Pss
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
158
Drying tunnel temperature set point.
1
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 57 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT105
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 018
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
1
2
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
70
52
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
Speed nr. 2
Wash time sp 2
sp2 rd2
100
38
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
63
1
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
Celsius visualization
Fahrenheit visualization r_A
GCU nSF
1
1 vedi par. A4.8
1
Indicates the type of rinse stage control.
Indicates the max. current deliverable to the gear motor by the inverter.
Tank temperature setting according to NSF standards.
Rinse autostart
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
198
Boiler temperature set point at start of rinse stage.
187
187
9
138
172
4
32
0
Boiler temperature set point.
Boiler warm-up temperature.
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
1
172
0
0
1
172
Type of wash module.
Tank temperature set point.
Tank hysteresis temperature.
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
220
180
Type of prewash module.
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
158
1
Drying tunnel temperature set point.
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 58 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT44B
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 023
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
12
-
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
31
44
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
63
22
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
53
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
1
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
1
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Tank temperature setting according to NSF standards.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
198
Boiler temperature set point at start of rinse stage.
187
187
Boiler temperature set point.
Boiler warm-up temperature.
126
138
158
9
32
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
172
0
Tank temperature set point.
Tank hysteresis temperature.
0
1
172
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PRy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
158
Drying tunnel temperature set point.
0
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 59 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT66B
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 024
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
14
-
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
31
85
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
88 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
63
42
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
48 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
55
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
1
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
1
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Tank temperature setting according to NSF standards.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
198
Boiler temperature set point at start of rinse stage.
187
187
Boiler temperature set point.
Boiler warm-up temperature.
126
138
158
9
32
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
172
0
Tank temperature set point.
Tank hysteresis temperature.
0
1
172
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PRy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
158
Drying tunnel temperature set point.
0
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 60 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT44C
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 025
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
12
-
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
31
44
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
63
22
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
53
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
1
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
1
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Tank temperature setting according to NSF standards.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
198
Boiler temperature set point at start of rinse stage.
50
50
Boiler temperature set point.
Boiler warm-up temperature.
126
32
158
9
32
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
172
0
Tank temperature set point.
Tank hysteresis temperature.
0
1
172
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PRy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
158
Drying tunnel temperature set point.
0
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 61 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT66C
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 026
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
14
-
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
31
85
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
88 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
63
42
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
48 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
55
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
1
Fahrenheit visualization
Rinse autostart
r_A
Indicates the type of rinse stage control.
GCU nSF
0
1 see par. A4.8
1
Up to serial number 81100000
From serial number 81100001
Indicates the max. current deliverable to the gear motor by the inverter.
Tank temperature setting according to NSF standards.
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
198
Boiler temperature set point at start of rinse stage.
50
50
Boiler temperature set point.
Boiler warm-up temperature.
126
32
158
9
32
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
172
0
Tank temperature set point.
Tank hysteresis temperature.
0
1
172
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PRy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
158
Drying tunnel temperature set point.
0
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 62 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTCS140O/RTCS140O
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 027
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
5
7
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
27
36
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
55 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
45
2
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
33 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
37
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius r_A
GCU nSF
0
1
1 see par. A4.8
0
Celsius visualization
Fahrenheit visualization
Indicates the type of rinse stage control.
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Rinse autostart
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
Boiler temperature set point.
Boiler warm-up temperature.
5
59
70
5
40
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
66
2
Tank temperature set point.
Tank hysteresis temperature.
0
1
64
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
1
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 63 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTCS180O/RTCS180O
1. GENERIC FUNC.
Set default par.
GFu sdp
Enter GENERIC FUNC. and set the following parameters.
1
Sets all parameters to their default value.
PROG 028
2.
Switch the machine off and then on again.
3. GENERIC FUNC.
GFu
Enter GENERIC FUNC. and set the following parameters.
Appl. type
APt
9
11
Type of machine: Without Dt
Type of machine: With Dt
Appl. direct.
Ad
Rack feed direction: Left
Speed nr. 1
Wash time sp 1
sp1 rd1
35
66
0
1
Rack feed direction: Right
Indicates feed gear motor operation frequency at speed 1 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 1 [s] is set.
(Set to
88 if Rinse autostart r_A
= 0)
Speed nr. 2
Wash time sp 2
sp2 rd2
58
40
Indicates feed gear motor operation frequency at speed 2 [Hz].
Time from when the last rack releases the auto start lever until the wash pumps stop when speed 2 [s] is set.
(Set to
48 if Rinse autostart r_A
= 0)
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
drE
H2C b_t btf
CF
39
0
0
0
Enable draining and cleaning cycles.
Wash tank heating element management.
Machine heating power management.
The tank is filled by means of a dedicated solenoid valve.
Unit of measure used in displaying the temperatures; if set to “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius r_A
GCU nSF
0
1
1 see par. A4.8
0
Celsius visualization
Fahrenheit visualization
Indicates the type of rinse stage control.
Indicates the max. current deliverable to the gear motor by the inverter.
Duo and tank temperature standard setting.
Rinse autostart
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
rin btS bot bti btd
Fbt dut dtH
Add dHU
Enter RINSE MODULE and set the following parameters.
92
Boiler temperature set point at start of rinse stage.
86
86
Boiler temperature set point.
Boiler warm-up temperature.
5
59
70
5
40
Boiler temperature decrease during standby.
First USA compact boiler temperature set point.
Tank temperature set point.
Tank hysteresis temperature.
Time from reaching level 0 (level in air trap) in the air gap, to stopping of the rinse pump.
0
Enables activation of the DUO heating element even if the tank and boiler heating elements are on.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
tub ttY tut ttH
CUn ttr
Enter WASH MODULE and set the following parameters.
2
Type of wash module.
66
2
Tank temperature set point.
Tank hysteresis temperature.
0
1
64
Without CU
With CU
Wash tank “warmup end” temperature.
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
PrE
PTy
SbL
Pss
Enter PREWASH MODULE and set the following parameters.
0
Type of prewash module.
220
180
Indicates the max. level in prewash tank.
Indicates the max. prewash tank level when the prewash pumps are working.
7. DT MODULE
DT temper
DT type
dt dtt d_t
Enter DT MODULE and set the following parameters.
70
Drying tunnel temperature set point.
1
Indicates the type of DT installed.
8.
Switch the machine off and then on again.
DOC. NO. 5956.573.04
P. 64 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
B1 SPECIFIC FUNCTIONS
B1.1
SETTING UNIT OF MEASURE IN FAHRENHEIT
The machines ( apart from Usa Compact machines) leave the factory with the unit of measure used for displaying temperatures in degrees Celsius (
Fahrenheit vis. = No only for Modular Rack Type and
CF= 0
only for Compact Rack Type).
To set the unit of measure used for displaying temperatures in degrees Fahrenheit, enter in GENERIC FUNC.
and set the
Fahrenheit vis. parameter = Yes (only for Modular Rack Type no USA) or enter in
GFu
and set the
CF
parameter to
1
(only for Compact Rack Type or USA Modular).
B1.2
LANGUAGE SETTING
The factory-set language on modular machines no USA is English. Set the required language using the
“LANGUAGE” parameter in the “USER SETTINGS” family.
B1.3
“MAX. MOTOR CURR.” PARAMETER ( GCU ) SETTING
1. Wait until the machine, complete with tables, is ready for a wash cycle.
2. Start a wash cycle and read the current absorbed by the gear motor
( refer to par. A1 “DISPLAY OF AUXILIARY VALUES”).
3. Add 2 to the read value (e.g. if “Motor current” = 34 ---> 34+2=36 decA).
4. Set the “Max. motor curr.” parameter with the value thus obtained.
WARNING:
The Rack Type leaves the factory with the “Max motor curr.” parameter already set to the optimum value. Reset it only when replacing a PCB or the gear motor.
WARNING:
The “Max motor curr.” ( GCU ) parameter indicates the max. current deliverable to the gear motor by
the inverter only if automatic current setting was not carried out (see paragraph A4.8 MOTOR ADJU-
procedure no longer have any effect on operation but the new current limit is represented by the
“Max motor curr.” ( GCU ) parameter.
DOC. NO. 5956.573.04
P. 65 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
C CONNECTORS LAYOUT
C1 POWER BOARDS CONNECTORS LAYOUT
LAYOUT 1 PREWASH ( MODULAR NON USA)
L3
L1
TY2
F8
F7
F9
F6
F5
F3
F2
F4
F1
F10
F11
F12
VDR12
TY1
R129
R122
OPTY2
OPTY1
F18
F17
F19
F15
F14
F13
F16
RL10
RL9
C10
RL8
F21
F20
F25
F24
F26
F23
F22
F28
F27
RL7
RL6
RL5
RL4_B RL3_B RL2_B
RL1_B
DOC. NO. 5956.573.04
P. 66 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 2 WASH ( MODULAR NON USA)
F26
F25
F27
F24
F23
F22
F21
F28
F20
F18
F17
F19
F15
F14
F13
F16
F9
F8
F7
F6
F4
F3
F2
F5
F1
F10
F11
F12
L3
L1
VDR12
R129
TY2
TY1
R122
RL9
RL10
OPTY2
OPTY1
RL8
RL6
RL5
RL7
C10
RL4_B RL3_B RL2_B
RL1_B
ONLY WITHOUT
PREWASH
DOC. NO. 5956.573.04
ONLY WITHOUT
PREWASH
P. 67 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 3 RINSE ( MODULAR NON USA)
L3
L1
TY2
F18
F17
F19
F16
F15
F14
F13
F9
F8
F7
F6
F5
F4
F3
F2
F1
F10
F11
F12
TY1
R122
VDR12
R129
RL10
RL9
OPTY2
OPTY1
RL8
F21
F20
F27
F26
F28
F25
F24
F23
F22
RL6
RL5
RL7
C10
RL4_B RL3_B RL2_B
RL1_B
DOC. NO. 5956.573.04
P. 68 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 4 DT ( MODULAR NON USA)
F19
F18
F17
F16
F15
F14
F13
F9
F8
F7
F6
F4
F3
F2
F5
F1
F10
F11
F12
L3
L1
VDR12
R129
TY2
TY1
R122
RL10
RL9
OPTY2
OPTY1
RL8
F21
F20
F28
F27
F26
F25
F24
F23
F22
RL6
RL5
RL7
C10
RL4_B RL3_B RL2_B
RL1_B
DOC. NO. 5956.573.04
P. 69 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
C2 MULTICONNECTOR BOARDS CONNECTORS LAYOUT
LAYOUT 5 PREWASH ( SHORT COMPACT / USA MODULAR)
NO USA
F4
F5
F6
F1
F2
F3
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
65
7
8
4
10
11
12
2 1
NO USA
NO USA
NO USA
DOC. NO. 5956.573.04
P. 70 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 6 WASH + RINSE (SHORT COMPACT)
F4
F5
F6
F1
F2
F3
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
7
65
8
11
10
12
4 3 2 1
DOC. NO. 5956.573.04
P. 71 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 7 DT / HAB ( SHORT COMPACT )
DOC. NO. 5956.573.04
BLACK
BLACK
RED
RED
F6
F7
F8
F9
F10
F11
F12
F1
F2
F3
F4
F5
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
65
7
8
11
10
12
4 3 2 1
WHITE
WHITE
P. 72 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 8 PREWASH ( SHORT COMPACT USA MODULAR)
5
5
J23
1
J25
2 1
1 2 1 2 1 6
6
J26
1
1
DOC. NO. 5956.573.04
1 6
1 7
1
3 1
1
J35
8
8
P. 73 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 9 WASH + RINSE ( SHORT COMPACT )
5
5
J23
1
J24
2 1
J25
2 1
1 2 1 2 1 6
6
J26
1
1
DOC. NO. 5956.573.04
1 1
1
J43
6 6
6
1
1
J36
7
7 1
1
J51
3
3
1
1
J35
8
8
P. 74 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 10 PREWASH (USA COMPACT)
F5
F6
F7
F8
F9
F10
F11
F12
F1
F2
F3
F4
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
7
65
8
11
10
12
4 3 2 1
DOC. NO. 5956.573.04
P. 75 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 11 WASH - RINSE 44" (USA COMPACT)
F6
F7
F8
F9
F10
F11
F12
F1
F2
F3
F4
F5
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
7
65
8
11
10
12
4 3 2 1
DOC. NO. 5956.573.04
P. 76 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 12 PREWASH 22" (USA COMPACT)
1
J42
8
5
5
J23
1
1 1
2
J25
1 6
1 6
J26
1
1
1
1
J37
9 1
9
8 1
1
J35
8
8
J27
3
1
J29
9
J30
1
1
4
6
J32
1
4
J34
1
DOC. NO. 5956.573.04
P. 77 / 100
J22
5
1
J21
2
1
J20
J43
1
J42
8
1
8
1
J41
J40
9
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 13 WASH + RINSE 44" (USA COMPACT)
5
5
J23
1
1 2
J24
1 2 1
J25
HACCP
6
1 1 6
J26
1
1
MACHINE WITH PREWASH
J27
3
1
J27
3
1
4
J28
1
9
J29
J30
1
4
J31
1
6
1
4
J32
1
4
J34
1
1
1
J37
9 1
9 1
J36
8 1
8 1
J35
8
8
DOC. NO. 5956.573.04
P. 78 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 14 RINSE 23" (USA MODULAR)
F6
F7
F8
F9
F10
F11
F12
F1
F2
F3
F4
F5
F13
F14
F15
F16
F17
F18
F19
F24
F25
F26
F27
F28
F20
F21
F22
F23
7
65
8
11
10
12
4 3 2 1
DOC. NO. 5956.573.04
P. 79 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 15 WASH 59" (USA MODULAR)
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
F1
F2
F3
F4 7
65
8
11
10
12
4 3 2 1
DOC. NO. 5956.573.04
P. 80 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 16 RINSE 23" (USA MODULAR)
5
5
J23
1
2 1
J24 J25
2 1
1 2 1 2 1 6
6
J26
1
1
DOC. NO. 5956.573.04
1 1
1
J43
6 6
6
1
1
J36
7
7
1 3
1
1
J35
8
8
P. 81 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LAYOUT 17 WASH 59" (USA MODULAR)
5
5
J23
1
2 1
2 1
J24 J25
1 2 1 2 1 6
6
J26
1
1
DOC. NO. 5956.573.04
1 6
1 7
1 3
1
1
J35
8
8
P. 82 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
C3 CONNECTORS LAYOUT LEGEND
F 3- F12
F13-F16
F20-F28
F21-F31
F32-F37
F38-F40
x1
x2
x4
x5
x6
x7
x8
x9
x10
Main supply connector
Loads connector
Loads connector
Loads connector
Loads connector
Loads connector
Temperature sensor connector
Temperature sensor connector
Temperature sensor connector
Thermal protection, autostart, emergency switch - feed back inverter
Board identification connector
Air gap pressure sensor connector
Gearmotor speed signal connector
Thermal protection, autostart, emergency switch
Door switch connector - user interface
C4 END LIMIT SWITCH, ENERGY PEAK CONTROL AND EMERGENCY SWITCH CONNECTIONS
C4.1
MODULAR (NO USA)
The left and right side panels of the dishwasher have a connector “B” (Figure 10), closed with a plug “A”
(Figure 10).
Unscrew plug “A” (Figure 10) anticlockwise.
C4.1.1
END LIMIT SWITCH CONNECTION
Connect END LIMIT SWITCH (Outfeed side machine) between points 11 and 12 (Figure 11).
C4.1.2
EMERGENCY SWITCH CONNECTION
Connect EMERGENCY SWITCH OUT (Outfeed side machine) between points 7 and 8 (Figure 11) .
Connect EMERGENCY SWITCH IN (Infeed side machine) between points 7 and 8 (Figure 11).
EMERGENCY
SWITCH (7-8)
B
A B
Figure 10 Electrical connection
END LIMIT
SWITCH (11-12)
Figure 11 Detail of electrical connection
DOC. NO. 5956.573.04
P. 83 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
C4.1.3
ENERGY PEAK CONTROL CONNECTION
Access to the electrical box of rinse module and connect ENERGY PEAK CONTROL between terminals 3 and 4 of terminal block X1.
ENERGY PEAK
CONTROL
X1 (3-4)
1 2 3 4 5 6 7 8 9 10 1112
Figura 12 ENERGY PEAK CONTROL CONNECTION
C4.2
USA MODULAR AND COMPACT SHORT
EMERGENCY
SWITCH
XIN (7-8)
EMERGENCY
SWITCH
XOUT (11-12)
END LIMIT
SWITCH
XOUT (1-2)
ENERGY PEAK
CONTROL
X4 (3-4)
DOC. NO. 5956.573.04
Figura 13 USA MODULAR AND COMPACT SHORT CONNECTIONS
P. 84 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
C4.3
USA COMPACT
C4.3.1
END LIMIT SWITCH CONNECTION
11 and 12. Connect END LIMIT SWITCH between terminals 11 and 12 of XC_OUT.
C4.3.2
EMERGENCY SWITCH CONNECTION
7 and 8. Connect EMERGENCY SWITCH OUT between terminals 7 and 8 of XC_OUT.
and 8. Connect EMERGENCY SWITCH IN between terminals 7 and 8 of XC_IN.
XC_OUT
XC_IN
END LIMIT
SWITCH
XC_OUT (11-12)
12
8
B
8
11
7
EMERGENCY
SWITCH
XC_OUT (7-8)
A
7
EMERGENCY
SWITCH
XC_IN(7-8)
Figura 14 END LIMIT SWITCH AND EMERGENCY SWITCH CONNECTION
C4.3.3
ENERGY PEAK CONTROL CONNECTION
5 1 1 1 6 1
ENERGY PEAK
CONTROL
X2 (7-8)
DOC. NO. 5956.573.04
Figure 15 ENERGY PEAK CONTROL CONNECTION
P. 85 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
D INVERTER PARAMETERS
WARNING:
When replacing the inverter remove the protection label “A” on the top of the same, as indicated below (the protection rating becomes IP20).
A
D1 INVERTER PROGRAMMING
D1.1
DISPLAY FUNCTIONS
Telemecanique
Altivar 11
3 “7 segment” displays.
Exits a menu or parameter or aborts the displayed value to return to the previous value in the memory.
Returns to the previous menu or parameter, or increases the displayed value.
Goes to the next menu or parameter, or decreases the displayed value.
Enters a menu or a parameter, or saves the displayed parameter or value.
ESC ENT
Pressing not store the selection
or does
Save the selection:
ENT
The display flashes when a value is stored.
DOC. NO. 5956.573.04
P. 86 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
D1.2
INVERTER CONTROL TERMINAL ELECTRICAL CONNECTIONS
(1) (2) (4) (5) (7) (8) (12)
KEY
COMPACT
SHORT
(1) White
(2) Orange
(4) Violet
(5) Red
(7) Black
(8) Yellow
(12) Blue
COMPACT
USA
(1) - 1 -
(2) - 2 -
(4) - 4 -
(5) - 5 -
(7) - 7 -
(8) - 8 -
(12) - 12 -
Figure 16 COMPACT RT Inverter electrical connection
(1) (2) (4) (5) (7) (8) (12)
KEY
(1) Black
(From Ser. Nr. 020)
(2) Orange
(From Ser. Nr. 020)
(4) Grey
(5) White
(7) Blue
(8) Green / Pink
(12) Brown / Yellow
Figure 17 MODULAR RT Inverter electrical connection
D1.3
INVERTER PARAMETER LISTS
Telemecanique speed drive Altivar 11 type ATV11PU12M2E380
Parameters for 110Vac gearmotor ( Delta connection)
Parameter
ACC dEC
LSP
HSP
ItH
SP2
SP3
SP4
Alt drC
Act
UnS
Description
Acceleration ramp time
Deceleration ramp time
Low speed
High speed
Motor thermal current
2nd preset speed
3rd preset speed
4th preset speed
Scale of analog input
Nominal motor voltage
Standard machine
3.0
0.5
0.0
100
3.6
10
25
50
10U
110
DOC. NO. 5956.573.04
P. 87 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Parameter
FrS
StA
FLG
UFr nCr
CLI nSL
SLP
COS
Description
Nominal motor frequency
Frequency loop stability
Frequency loop gain
Ir compensation
Nominal motor current
Current limit
Nominal motor slip
Slip compensation
Nominal motor cosine
Standard machine
50
20
50
50
3.6
3.9
5
100
0.65
FUn tCC rrS
Ps2
HSP tLS
PI
LOC tOL
API
LUL tUL rSF rP2
LC2 nST
StP brA
AdC
SfT
FLr dO
Atr bFr
SCS
FCS
ACt tCt
LIA
LIB
LIA
LIB
PIF
LI
LI
ACt tdC
SdC
ACt
Sfr
ACt
Type of control
Type of two wire control
Reverse
Preset speed lia
Preset speed lib
Config. input Lia
Config. input Lib
Overload threshold
Time delay for overl. func.
Histeresis freq. reached
Underload threshold
Time delay for underl. func.
Fault reset
0.3
60
10 nO
Second ramp
2nd limit current nO nO
Freewheel stop nO
Controlled stop on loss of line FST nO nO nO
0.0
nO
90
0
2C
Lel nO nO
Deceleration ramp adaptation
Automatic dc injection
Injection time on stopping
Injection current
Frequency range
Switching frequency
Catch on the fly
Analogic output do
Automatic restart
Motor frequency
Configuration backup
Reminder of the configuration
OCr nO
50 nO nO
YES
YES
0.5
2.9
LF
4 nO
Telemecanique speed drive Altivar 11 type ATV11PU12M2E380 o ATV11PU09M2E380
Parameters for 230Vac gearmotor ( Delta connection)
Parameter
ACC dEC
LSP
HSP
ItH
SP2
SP3
SP4
Description
Acceleration ramp time
Deceleration ramp time
Low speed
High speed
Motor thermal current
2nd preset speed
3rd preset speed
4th preset speed
Standard machine
3.0
0.5
0.0
100 Modular no USA
115 Modular USA
1.7
10
25
50
DOC. NO. 5956.573.04
P. 88 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Parameter
Alt drC
FUn nCr
CLI nSL
SLP
COS tCC
Act
UnS
FrS
StA
FLG
UFr rrS
Ps2
HSP tLS
PI
LOC tOL
API
LUL tUL rSF rP2
LC2 nST
StP brA
AdC
SfT
FLr dO
Atr bFr
SCS
FCS
LI
LI
ACt tdC
SdC
ACt
Sfr
ACt
ACt tCt
LIA
LIB
LIA
LIB
PIF
Description Standard machine
Scale of analog input
Nominal motor voltage
Nominal motor frequency
Frequency loop stability
Frequency loop gain
Ir compensation
Nominal motor current
Current limit
Nominal motor slip
Slip compensation
Nominal motor cosine
Type of control
Type of two wire control
Reverse
Preset speed lia
Preset speed lib
Config. input Lia
Config. input Lib
Overload threshold
Time delay for overl. func.
Histeresis freq. reached
Underload threshold
Time delay for underl. func.
Fault reset
Second ramp
2nd limit current
Freewheel stop
Controlled stop on loss of line supFST
Deceleration ramp adaptation YES
Automatic dc injection
Injection time on stopping
YES
0.5
Injection current
Frequency range
Switching frequency
1.4
Lf
4
Catch on the fly
Analogic output do
Automatic restart
Motor frequency
Configuration backup
Reminder of the configuration nO
FtA nO
50 nO nO nO nO nO nO
0
0.3
60
0 nO nO nO nO
0.0
nO
90
1.7
3.1
2
100
0.65
2C
LEL nO
10U
230
50
20
50
50
DOC. NO. 5956.573.04
P. 89 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
E WARNING MESSAGES AND TROUBLESHOOTING
List of possible documented machine alarms:
20
21
22
**
23
16
17
18
19
**
CODE
11
12
13
14
15
*
DESCRIPTION
The Air Gap was not completely filled within the max. filling time.
POSSIBLE CAUSE
- The air gap water supply cock is not open.
- The water filling solenoid valve doesn’t work properly.
- The water feed flow is too low.
- The water inlet filter is not clean.
- The boiler pressure sensor doesn’t work properly.
The pressure sensor on the air gap does not work correctly.
The Duo-Rinse tank was not completely filled within the max.
filling time.
- The pressure sensor on the air gap doesn’t work properly.
- The pressure sensor connector on the air gap is not correctly inserted.
- The X7 connector on the rinse board is not correctly inserted.
- The impeller rotation is wrong.
- There is a leak in the plumbing circuit that connects the air gap to the rinse jets.
- There is a leak in the CU.
- The non return valve on the air gap doesn’t work properly.
- The DUO tank overflow is not inserted.
- The Duo drain solenoid valve doesn’t work properly and remains open.
- The pressure sensor on the rinse board doesn’t work properly.
- The rinse board doesn’t work properly.
The pressure sensor on the Duo-
Rinse tank does not work correctly.
The required temperature was not reached in the boiler within the max.
heating time.
The water temperature in the boiler is too high.
- The pressure sensor on the rinse board doesn’t work properly.
- The rinse board doesn’t work properly.
- The rinse water flow is too high.
- A heating element or a heating element branch doesn’t work properly.
- The CU is not clean.
- The boiler temperature sensor doesn’t work properly.
- The boiler heating element starter controller doesn’t work properly or its coil is not correctly
connected to the rinse board.
- The “Boil. temp. start” parameter ( bt5) or the “Boiler temper.” parameter (bot) has been
changed.
- The relay that activates the boiler heating elements starter controller is stuck.
- The boiler temperature sensor is short-circuited.
The boiler temperature sensor is short-circuited.
The boiler temperature sensor is open.
The required temperature was not reached in the Duo-Rinse tank within the max. heating time.
The water temperature in the Duo-
Rinse tank is too high.
The Duo-Rinse tank temperature sensor is short-circuited.
The Duo-Rinse tank temperature sensor is open.
- The boiler temperature sensor is open or disconnected.
- The boiler temperature sensor connector is not correctly inserted.
- The connector on the rinse board is not correctly inserted.
- The Duo rinse heating element doesn’t work properly.
- The Duo rinse temperature sensor doesn’t work properly.
- The Duo rinse heating element starter controller doesn’t work properly or its coil is not correctly
connected to the rinse board.
- The “Duo temper.” parameter ( dut) has been changed.
- The relay that activates the Duo rinse heating element starter controller is stuck.
- The Duo rinse temperature sensor is short-circuited.
SHORT compact and modular:The rinse pump thermal protector has tripped.
USA compact: the thermal protector of one of the following users has tripped:
- wash pump
- rinse pump
- CU fan.
- The Duo rinse temperature sensor is open or disconnected.
- The Duo rinse temperature sensor connector is not correctly inserted.
- The connector on the rinse board is not correctly inserted.
- The rinse pump thermal protector is not correctly set.
- The rinse pump doesn’t work properly.
- The rinse pump impeller is blocked.
- The wash pump thermal protector is not correctly set.
- The wash pump does not work properly.
- The wash pump impeller is blocked.
- The "Wash module" parameter (ttY) is not correctly set.
- The CU fan thermal protector is not correctly set.
- The CU fan does not work properly.
- The rinse pump thermal protector is not correctly set.
- The rinse pump does not work properly.
- The rinse pump impeller is blocked.
24
**
25
**
The Duo-Rinse pump thermal protector has tripped.
The Duo-Rinse tank was not completely emptied within the max.
emptying time.
- The Duo rinse pump thermal protector is not correctly set.
- The Duo rinse pump doesn’t work properly.
- The Duo pump impeller is blocked.
- The drain is blocked.
- The drain solenoid valve doesn’t work properly.
- The Duo rinse tank air trap is not clean.
DOC. NO. 5956.573.04
P. 90 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
27
30
**
31
32
33
**
The gear motor inverter has generated an allarm.(compact machines only).
The Air gap was not completely emptied within the max. emptying time.
The wash tank was not completely filled within the max. filling time.
The pressure sensor on the wash tank does not work correctly.
- The inverter or the gear motor doesn’t work properly. Possible machine alarms documented on
1)
OCF overcurrent
Possible cause Remedy
2)
3)
SCF motor short circuit
InF internal fault
- ramp too short
- inertia or load too high
- mechanical locking
- insulation fault or short-
circuit at the drive output
- internal fault
- check the state of the
mechanism.
- check the cables connecting the drive to the motor , and the motor insulation.
- check the environment
(electromagnetic compatibility).
- send the drive to be checked/repaired.
- return to factory settings.
4)
5)
6)
CFF configuration fault
SOF overspeed
CrF internal fault
- The current configuration is
inconsistent
- some parameters in the
inverter have been modified
- instability or
- driving load too high
- some parameters in the
inverter have been modified
- load relay control fault or
damaged load resistor
- drive temperature too high
- return to factory settings.
- replace the drive.
7)
8)
9)
OHF drive overload
OLF motor overload
OSF overvoltage
10)
11)
12)
ObF overvoltage during deceleration
PHF line phase failure
USF undervoltage
- triggered by motor current
too high
- line voltage too high
- disturbed line supply
- braking too sudden or
driving load.
- drive incorrectly supplied or a fuse blown
- failure of one phase
- unbalanced load
- line supply too low
- transient voltage dip
- damaged load resistor
- check the motor load and the enviroment.Wait
for the drive to cool down before restarting.
- check the motor load.
Wait for the drive to cool down before restarting.
- check the line voltage.
The overvoltage thresold is 415 V on the DC bus.
- increase the deceleration time.
- check the power connection and the fuses.
- reset.
- check the voltage and
the voltage parameter.
The undervoltage
threshold is 230 V on the
DC bus.
- replace the drive.
- The impeller rotation is wrong.
- The non return valve on the air gap doesn’t work properly.
- The pressure sensor on the air gap doesn’t work properly.
- The air gap air trap is not clean.
- The wash tank water supply cock is not open.
- The water load solenoid valve doesn’t work properly.
- The water feed flow is too low.
- The water inlet filter is not clean.
- The pressure sensor on the wash tank doesn’t work properly.
- The wash tank overflow has not been inserted.
- The wash tank drain solenoid valve doesn’t work properly and remains open.
- The pressure sensor on the wash board doesn’t work properly.
- The wash board doesn’t work properly.
- The pressure sensor on the wash board doesn’t work properly.
- The wash board doesn’t work properly.
The required temperature in the wash tank was not reached within the max. heating time.
- A heating element or a heating element branch of the wash board doesn’t work properly.
- The wash tank temperature sensor doesn’t work properly.
- The wash tank heating element starter controller doesn’t work properly or its coil is not correctly
connected to the rinse board.
DOC. NO. 5956.573.04
P. 91 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
34
35
36
**
37
***
38
**
39
**
The water temperature in the wash tank is too high.
- The “Tank temper.” parameter ( tut) or the “Sanit. temper.” parameter (tSt) has been
changed.
- The relay that activates the wash tank heating elements starter controller is stuck.
The wash tank temperature sensor is short-circuited.
The wash tank temperature sensor is open.
The upper wash pump thermal protector has tripped (SHORT compact and modular machines only).
The lower wash pump thermal protector has tripped.
( modular machines only )
The CU (Condensing unit) fan thermal protector has tripped.
(SHORT compact and modular machines only).
- The wash tank temperature sensor is short-circuited.
- The wash tank temperature sensor is open or disconnected.
- The wash tank temperature sensor connector is not correctly inserted.
- The connector on the wash board is not correctly inserted.
- The upper wash pump thermal protector is not correctly set.
- The upper wash pump doesn’t work properly.
- The upper wash pump impeller is blocked.
- The lower wash pump thermal protector is not correctly set.
- The lower wash pump doesn’t work properly.
- The lower wash pump impeller is blocked.
- The “Wash module” parameter ( ttY) is not correctly set.
- The CU (Condensing Unit) fan thermal protector is not correctly set.
- The CU fan doesn’t work properly.
54
55
56
**
57
**
58
**
60
61
40
**
51
52
53
**
62
71
**
72
73
The wash tank was not completely emptied within the max. emptying time.
- The drain is blocked.
- The drain solenoid valve doesn’t work properly.
- The wash tank air trap is not clean.
The prewash tank was not completely filled within the max.
filling time.
- The prewash tank water supply cock is not open.
- The water load solenoid valve doesn’t work properly.
- The water feed flow is too low.
- The water inlet filter is not clean.
- The load solenoid valve filter is not clean.
- The prewash tank pressure sensor doesn’t work properly.
- The prewash tank overflow has not been inserted.
- The prewash tank drain solenoid valve doesn’t work properly and remains open.
- The pressure sensor on the prewash board doesn’t work properly.
- The prewash board doesn’t work properly.
The pressure sensor on the prewash tank does not work correctly.
The required temperature in the prewash tank was not reached within the max. heating time.
- The pressure sensor on the prewash board doesn’t work properly.
- The prewash board doesn’t work properly.
- A heating element or a heating element branch of the prewash board doesn’t work properly.
- The prewash tank temperature sensor doesn’t work properly.
- The prewash tank heating element starter controller doesn’t work properly or its coil is not
correctly connected to the rinse board.
The water temperature in the prewash tank is too high.
The prewash tank temperature sensor is short-circuited.
The prewash tank temperature sensor is open.
- The “Tank temper.” parameter (
Prt) or the “Sanit. temper.” parameter (PSt) has been
changed.
- The relay that activates the wash tank heating elements remote control switch is stuck.
- The prewash tank temperature sensor is short-circuited.
The prewash pump thermal protector has tripped.
The prewash tank was not completely emptied within the max.
emptying time.
The CU temperature sensor is shortcircuited (machines with heat pump only).
The CU temperature sensor is open
(machines with heat pump only).
- The prewash tank temperature sensor is open or disconnected.
- The prewash tank temperature sensor connector is not correctly inserted.
- The connector on the prewash board is not correctly inserted.
- The prewash pump thermal protector is not correctly set.
- The prewash pump doesn’t work properly.
- The prewash pump impeller is blocked.
- The drain is blocked.
- The drain solenoid valve doesn’t work properly.
- The prewash tank air trap is not clean.
- The CU temperature sensor or the connection wires are short-circuited.
- The CU temperature sensor or the connection wires are open.
- The CU temperature sensor connector is not properly inserted.
- The connector on the wash card is not properly inserted.
Check the heat pump.
The heat pump has generated an error (machines with heat pump only).
The required temperature in the drying tunnel was not reached within the max. heating time.
The drying tunnel temperature is too high.
The drying tunnel temperature sensor is short-circuited.
- The DT heating element or the DT heating element branch doesn’t work properly.
- The DT temperature sensor doesn’t work properly.
- The DT heating element starter controller doesn’t work properly or its coil is not
correctly connected to the rinse board.
- The “Dt temper.” parameter ( dtt) has been changed.
- The relay that activates the DT heating element starter controller is stuck.
- The DT fan doesn’t work properly.
- The DT temperature sensor doesn’t work properly.
- The DT temperature sensor is short-circuited.
DOC. NO. 5956.573.04
P. 92 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
74
****
75
**
76
77
The drying tunnel temperature sensor is open.
The drying tunnel fan thermal protector has tripped.
The gear motor supplied current is higher than the maximum value allowed for the “Max motor curr.”.
- The DT temperature sensor is open or disconnected.
- The DT temperature sensor connector is not correctly inserted.
- The connector on the DT board is not correctly inserted.
- The DT fan thermal protector is not correctly set.
- The DT fan doesn’t work properly.
- The wire connected from the inverter ( Do terminal block) to the elctronic board (X7-5) is shortcircuited with the ground.
- The inverter parameters are not correctly set.
The gear motor supplied current is lower than the minimum value allowed for the gear motor current.
- The wire connected from the inverter ( Do terminal block) to the electronic board (X7-5) is open.
- The inverter parameters are not correctly set.
- The gear motor is configured with star connection and it must be configured with delta connections.
82
83
84
85
**
89
90
( modular machines non USA)
CoM
Err
( compact machines or USA modular)
The required temperature was not reached in the first boiler within the max. heating time.
The water temperature in the first boiler is too high.
- The rinse water flow is too high.
- A heating element or a heating element branch doesn’t work properly.
- The CU is not clean.
- The first boiler temperature sensor doesn’t work properly.
- The first boiler heating element starter controller doesn’t work properly or its coil is not correctly
connected to the rinse board.
- The “Boil. temp. start” parameter ( bt5) or the “Boiler temper.” parameter (bot) has been
changed.
- The relay that activates the first boiler heating elements starter controller is stuck.
- The first boiler temperature sensor is short-circuited.
The first boiler temperature sensor is short-circuited.
The first boiler temperature sensor is open.
The temperature on the user interface is too high.
Communication problems between machine electronic boards.
- The first boiler temperature sensor is open or disconnected.
- The first boiler temperature sensor connector is not correctly inserted.
- The connector on the rinse board is not correctly inserted.
- Presence of steam too hot on the user interface board.
- The user interface doesn’t work properly.
- The bus connection cables are not correctly connected to all the boards.
- One or more boards don’t work properly.
- The “Appl. type” parameter (APt) is not correctly set.
- The connector X6 is not correctly connected.
When alarm 90 appears, the display will show the name (modular rack type no USA) or the number (compact rack type or USA Modular), of the electronic board that generated the communication error.
1: rinse (on USA modular versions only)
2: wash (USA modular versions) or wash + rinse (compact)
3: prewash
4: dt
If, after a communication error, the machine is able to re-enable the communication between the boards, the following message appears on the display:
91
Modular
PRESS
I
Compact
No
CoM
Err
- The user interface board doesn’t work properly (modular rack type).
User interface board (modular rack type non USA) out of order.
USA compact machines: Power card connected to the user interface card not working.
The Power card connected to the user interface card does not work.
The user interface card does not work.
The connection between the user card and Power card is damaged.
* If the value of the parameter "Heat tim. enable" (HtE) is "Yes" (1), the machine stops when this alarm appears. If the parameter value is "No" (0), the machine does not shut down when this alarm appears.
** The machine does not shut down if these alarms appear. Every 8 seconds a message indicating the alarm number, the alarm is shown on the display. A red LED blinks, but the machine continues to carry out the normal operations.
*** This alarm causes machine stop in versions without prewash and with just one wash pump. In WTM140 versions the machine stops when this alarm appears. In all the other models the machine continues to work.
**** With Dt/ Hab standard models the machine shuts down when this alarm appears, but does not in the new Dt/ Hab versions.
DOC. NO. 5956.573.04
P. 93 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
F MODULE COMPOSITION FOR RACK TYPE
MODULAR RACK TYPE / USA
WTM140 / RTM140
WTM165 / RTM165 / WT82
WTM180 / RTM180
WTM200 / RTM200 / WT105
WTM250
WTM300
SHORT COMPACT RACK TYPE /
USA
RTCS90/WTCS90
RTCS140/WTCS140
RTCS180/WTCS180
RTCS250/WTCS250
WT44
WT66
RINSE
600
X
X
X
X
X
X
WASH + RINSE
1165
X
-
X
-
-
-
WASH
1490
-
X
-
X
X
X
X
X
X
44’’
X
X
X
-
-
X
22’’
-
-
X
X
-
-
600
-
-
X
PREWASH
PREWASH
1165
-
-
-
-
X
-
X
-
-
44’
-
-
-
1490
-
-
-
-
-
X
DOC. NO. 5956.573.04
P. 94 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
G FLOWCHARTS FOR TROUBLESHOOTING
COMPACT SHORT
START
CoM Err 2 or CoM Err 3 or CoM Err 2 - 4 or CoM Err 2 - 3 - 4 or CoM Err 3 - 4 alarm (*)
(*) If CoM Err1 appears among the communication alarms, correctly set parameter "Apt".
DOC. NO. 5956.573.04
Check the continuity of the bus communication cable and that it is properly inserted between the User card and the various
MEC's (see communication cable and bus cable path).
YES
Make sure connector X6 and relevant jumpers (see
Layout 5/ 6/ 7 - page 68, 69 and 70) are properly inserted in the respective MEC's.
NO
Correctly insert it or replace if necessar
NO
Correctly insert them or replace if the contact is open.
YES
Make sure the parameter "Apt" is correctly set according to the type of machine.
NO
Check the values of parameter "Apt" as indicated in par. A.4.1.2. Generic.Func.
YES
Check the correct power supply
230V (-15% ; +10%) on board
AP1 between connector X1
(contact 3) and connector X3
(contact 1).
NO
Replace User A1.
YES
Check the correct power supply
230V (-15% ; +10%) on User card A1 on connector J21 (contacts 1 and 4).
NO
Check the wiring between connector X3 of
AP1 and connector X21 of AP1 (also check the respective through-wall fitting XC2) and repair/replace the damaged component if necessary.
YES
Check the correct power supply
230V (-15%; +10%) on board
AP1 in connector J26 (contacts
1 and 2).
NO
Replace the User AP1.
YES
Continued on the next page.
P. 95 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
YES
Check the correct power supply
230V (-15%; +10%) on MEC board A2 in connectors F1/F4
(see Layout 6 - page 69 - contacts 1 and 2).
NO
Check the integrity and continuity of the wiring between connector J26 (on board AP1) and connector F1/F4 (on board A2), and replace it or repair if necessary.
NO
YES
If the alarm is only CoM Err2 and there is no error CoM
Err3 or CoM Err4 in progress.
NO
Is the Prewash module installed?
YES
YES
Check the correct power supply
230V (-15%; +10%) on board
AP1 in connector J24 (contacts
1 and 2).
NO
Replace board AP1.
YES
Check the wiring, the through-wall fittings
(XC_4 - Wash+Rinse zone, (XC_35 - Prewash zone 44" and (XC_44 - Prewash zone
22") and the connectors, and repair/replace if necessary.
YES
Check the correct power supply
230V (-15%; +10%) on board
AP4/AP5 in connector J26 (contacts 1 and 2).
NO
Replace boards AP4/AP5.
NO
Is the DT module installed?
YES
YES
Check the correct power supply
230V (-15%; +10%) on board MEC
A6 (prewash zone) in connector
F1/F4 (see Layout 5 - page 68 contacts 1 and 2).
NO
Check the integrity and continuity of the wiring between connector J26 (on board AP4/
AP5) and connector F1/F4 (on board A6), and replace/repair if necessary.
YES
Return to the wash zone.
Check the correct power supply
230V (-15%; +10%) on board
AP1 in connector J25 (contacts
1 and 2).
YES
Continued on next page.
NO
Replace boards AP1.
DOC. NO. 5956.573.04
P. 96 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
YES
Check the correct power supply
230V (-15%; +10%) on board
MEC A7 (DT/HAB zone) in connector F1/F4 (see Layout 7 page 70 - contacts 1 and 2).
NO
Check the wiring, the through-wall fittings
(XC_3 - Wash+Rinse zone) and the connectors between board AP1 in connector J25 and MEC board A7 in connector F1/F4, and repair/replace if necessary.
NO
Check if on disconnecting the bus cable from MEC board A7 (DT/
HAB zone) the CoM Err4 alarm or
CoM Err 2/4 alarm change to CoM
Err4 or CoM Err 3-4 alarm changes to CoM Err 4.
YES
Replace MEC board A7 (DT/HAB zone).
NO
Reconnect the bus cable to MEC board A7 (DT/HAB zone).
NO
Is the Prewash installed?
YES
NO
Disconnect the bus cables connected to the Wash+Rinse card (1 or 2 depending on the type of machine). Does CoM Err 2-3-4 alarm become CoM Err 2-4 or CoM Err
2-3 alarm become CoM Err 2?
NO
Replace MEC board A4/A5
(Prewash zone).
YES
Replace MEC board A2 (Wash + Rinse zone).
END
COMMUNICATION CABLE PATH
W+R
DT
W+R
DT W+R PW
BUS CABLE
DOC. NO. 5956.573.04
P. 97 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
SHORT COMPACT
START
Alarm 27: the drive gearmotor inverter has generated an alarm.
Check if inverter display is on.
NO
YES
Check if the parameters are correct.
NO
Correctly enter them according to that indicated in par. D page
82
YES
Check the correct power supply 230V (-15%;
+10%) between terminals
1 and 2 of the inverter.
YES
Replace the inverter.
NO
Check the correct power supply 230V (-15%;
+10%) on board AP1 on connector J21 (contacts 7 and 8).
NO
Check the wiring and connector.
YES
Check the correct power supply 230V (-15%;
+10%) on board AP1 on connector J23 (contacts 3 and 4).
NO
YES
Check the correct power supply 230V (-15%;
+10%) on board AP1 on connector J21 (contacts 5 and 8).
NO
Check the correct power supply 230V (-15% ;
+10%) on the disconnecting switch box if between connectors F1, F2,
F3 and F4.
YES
NO
Mains power trouble.
Replace board AP1.
Check continuity between points RC or RA of the inverter with the machine switched on.
NO
YES
Check the wiring or replace the inverter.
Display the alarms table
27 see par. E page 85.
Check the wiring and connectors.
YES
Check the correct power supply 230V (-15%;
+10%) on board AP1 on connector J21 (contacts 6 and 8).
NO
Replace transformer GS1 or check the wiring or connectors.
YES
Check the correct power supply 230V (-15% ;
+10%) on board AP1 on connector J21 (contacts 7 and 8).
NO
Replace board AP1.
YES
Check the wiring between the inverter and board AP1 and replace the inverter if necessary.
END
DOC. NO. 5956.573.04
P. 98 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
SHORT COMPACT RTCS90/ WTCS90 AND RTCS140/ WTCS140 WITHOUT DT/HAB
START
Alarm EMR: error message on display.
Interruption in emergency circuit.
Check the connection of the emergency buttons on auxiliary board AP1 (located inside the electrical box in the wash zone).
See figure Layout 9 - page 72 - terminal x_IN (contacts 7 and 8) and X_OUT (contacts 11 and
12).
NO
YES
Correctly connect and make sure the insulation is not pinched.
Make sure the emergency buttons have not been activated.
YES
NO
Deactivate the emergency buttons.
YES
Check continuity on the board AP1 between contacts 7-8 of Terminal Block
X-IN and contacts 11-12 of
Terminal Block X-OUT.
NO
YES
Check the emergency circuit power supply voltage.
Make sure the wiring between board AP1 and each of the emergency buttons is not interrupted.
NO
Check the correct 24V output power supply from transformer GS1 (connector J49 contact 1 and connector J50 contact 2).
NO
Replace/repair the wiring.
Replace the faulty buttons.
YES
Check the correct 230V input power supply to the transformer GS1 (connector J44, contacts 1-3), checking on the transformer terminal board.
YES
Check the continuity between connector J49 (contact 1 on
GS1) and connector J32 (contact 6 on AP1) and between connector J50 (contact 2 on GS1) to
J32 (contact 2 on AP1).
YES
NO
Replace the transformer.
Check the wiring and connectors and repair/replace if necessary.
Check continuity between connector J32 (contact 3 on AP1) to terminal X_OUT (contact 9 on AP1).
NO
YES
Replace board AP1.
Check the continuity between connector J32 (contact 2 on AP1) and connector J27 (contact 3 on
AP1).
YES
NO
Replace board AP1.
DOC. NO. 5956.573.04
P. 99 / 100
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
YES
Check the continuity between connector J32 (contact 3 on AP1) and connector J27 (contact 1 on
AP1).
YES
NO
Check the jumper on board AP1 (terminal
X_OUT between contacts 9 and 10 or 10 and 11). If correct, replace board AP1.
Check the continuity between connector J27 (contact 1 on
AP1) and connector F20/F23
(contact 4 on A2) and between connector J27 (contact
3 on AP1) and contactor F20/
F23 (contact 2 on A2).
YES
NO
Check the wiring and connectors and repair/replace if necessary.
Replace MEC board A2.
END
DOC. NO. 5956.573.04
P. 100 / 100
Pobierz
Reklama