Panasonic Ductless Brochure
Wall Mounted Air Conditioners & Heat Pumps
8,500 - 24,000 BTU/H
17.5 - 21.0 SEER
Panasonic’s Ductless Split Air
Conditioner and Heat Pump products
offer a variety of options to cater
to your in-home cooling and
heating needs. Installation is simple
because no duct work is required.
Environmentally friendly refrigerant
and inverter technology combine to
provide superior performance – with
the added benefit of very low energy
consumption. Panasonic ductless
systems allow you to relax and enjoy
in quiet comfort.
Features
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Microprocessor Controlled Operation
Dry Mode
Automatic Fan Operation/3 Fan Speeds
Electronic Refrigerant Control Valve
Air Sweep Control
High Power Mode
Quiet Mode
Self-Diagnostic Function
Wireless Remote Control Operation
Hot Start Heating System
1-Hour Off Timer
24-Hour Programmable Clock
Night Set-Back Capability
Anti-Mold Filter
Air Clean Apatite Filter
Automatic Restart After Power Failure
Wireless
Remote Controller
Wired
Remote Controller
(CZ-RD516C)
(Optional)
Optional Accessories
-
-
-
-
-
Outdoor Unit Wall Mounting Brackets
Locking Wireless Remote Bracket
Mini In-Line Condensate Pumps
Wired Remote Controller
Wind Baffle
Outdoor Unit
(Not shown to scale)
Wall Mounted Air Conditioners — Low Ambient Models
Unit Model No.
Performance & Electrical Ratings
Capacity
Cooling
Btu/h
Moisture Removal
High
Pints/H
Dry Air Flow
HighCFM
SEER
Cooling
EER
Cooling
Power Supply
V, Phase, Hz
Running Amps
CoolingA
Power Input
CoolingW
Fuse or Circuit Breaker Capacity
A
Features
Controls
Low Ambient Control
Wireless Remote Controller
Wired Remote Controller (optional)
Fan Speeds
Timer
Horizontal
Air Deflection
Vertical
Air Filter
Refrigerant
Refrigerant Control
In (Hi/Lo/Q-Lo)
dB-A
Operation Sound
Outdoor(Hi)dB-A
Type
Refrigerant Piping
Dischargein.
Suctionin.
Refrigerant Pipe Length
ft.
Outdoor Above
ft.
Elevation Difference*
Outdoor Below
ft.
Dimensions & Weight
Height
in.
Width
in.
Depth
in.
ENERGY STAR®
Indoor Unit
CS-S9NKUA
Outdoor Unit
CU-S9NKUA
Indoor Unit
CS-S12NKUA
Outdoor Unit
CU-S12NKUA
Indoor Unit
CS-S18NKUA
Outdoor Unit
CU-S18NKUA
Indoor Unit
CS-S24NKUA
Outdoor Unit
CU-S24NKUA
8,500(4,100~10,200)
1.3
395
21.0
13.1
230/208V, 1PH, 60Hz
3.1/3.5(~4.4)
650(250~850)
15
12,000(4,100~13,300)
2.5
425
20.0
12.0
230/208V, 1PH, 60Hz
4.7/5.2(~6.8)
1,000(250~1,150)
15
17,100(5,800~19,800)
3.0
650
18.0
13.2
230 / 208V, 1PH, 60Hz
5.95/6.60
1,300(-)
20
24,000(5,800~27,200)
7.6
650
17.5
10.2
230 / 208V, 1PH, 60Hz
10.75/11.90
2,350(-)
20
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Manual
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
40 / 25 / 20
47
Flare
1/4”
3/8”
Max. 66
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
21-9/32”
34-9/32"
30-23/32”
8-1/16”
11-13/32”
Yes
Yes
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Manual
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
43 / 28 / 20
48
Flare
1/4”
1/2”
Max. 66
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
21-9/32”
34-9/32"
30-23/32”
8-1/16”
11-13/32”
Yes
Yes
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Automatic
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
47 / 39 / 36
49
Flare
1/4”
1/2”
Max. 100
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
31-5/16”
42-5/32"
34-15/32”
9-9/32”
12-5/8”
Yes
Yes
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Automatic
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
48 / 40 / 37
51
Flare
1/4”
5/8”
Max. 131
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
31-5/16”
42-5/32"
34-15/32”
9-9/32”
12-5/8”
–
–
*This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Wall Mounted Heat Pumps — Low Ambient Models
Unit Model No.
Performance & Electrical Ratings
Cooling
Btu/h
Capacity
HeatingBtu/h
Moisture Removal
High
Pints/H
Dry Air Flow
HighCFM
SEER
Cooling
EER
Cooling
HSPF
Heating
Power Supply
V, Phase, Hz
CoolingA
Running Amps
HeatingA
CoolingW
Power Input
HeatingW
Fuse or Circuit Breaker Capacity
A
Features
Controls
Low Ambient Control
Wireless Controller
Wired Remote Controller (optional)
Fan Speeds
Timer
Horizontal
Air Deflection
Vertical
Air Filter
Refrigerant
Refrigerant Control
In (Hi/Lo/Q-Lo) dB-A
Operation Sound
Outdoor(Hi)dB-A
Type
Refrigerant Piping
Dischargein.
Suctionin.
Refrigerant Pipe Length
ft.
Outdoor Above
ft.
Elevation Difference*
Outdoor Below
ft.
Dimensions & Weight
Height
in.
Width
in.
Depth
in.
Net Weight
lbs.
ENERGY STAR®
Indoor Unit
CS-E9NKUAW
Outdoor Unit
CU-E9NKUA
Indoor Unit
CS-E12NKUAW
Outdoor Unit
CU-E12NKUA
Indoor Unit
CS-E18NKUA
Outdoor Unit
CU-E18NKUA
Indoor Unit
CS-E24NKUA
Outdoor Unit
CU-E24NKUA
8,500(4,100~10,200)
11,200(4,100~14,100)
1.3
395
21.0
13.1
10.5
230/208V, 1PH, 60Hz
3.1(~7)
5.4(~7)
650(250-850)
1,150(200-1,500)
15
12,000(4,100~13,300)
13,800(4,100~16,300)
2.5
425
20.0
12.0
10.6
230/208V, 1PH, 60Hz
4.7(~7.8)
5.8(~7.8)
1,000(250-1,150)
1,300(200-1,710)
15
17,100(5,800-19,800)
20,400(5,800-20,800)
3.0
650
18.0
13.2
8.5
230/208V, 1PH, 60Hz
5.95 / 6.60
7.20 / 8.00
1,300(-)
1,600(-)
20
24,000(5,800-27,200)
28,800(5,800-29,200)
7.6
650
17.5
10.2
8.5
230/208V, 1PH, 60Hz
10.75 / 11.90
11.40 / 12.60
2,350(-)
2,500(-)
20
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Manual
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
40 / 25 / 20
47
Flare
1/4”
3/8”
Max. 66
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
21-9/32”
34-9/32”
30-23/32”
8-1/16”
11-13/32”
20.0
82.0
Yes
Yes
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Manual
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
43 / 28 / 20
48
Flare
1/4”
1/2”
Max. 66
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
21-9/32”
34-9/32”
30-23/32”
8-1/16”
11-13/32”
20.0
82.0
Yes
Yes
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Automatic
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
47 / 39 / 36
51
Flare
1/4”
1/2”
Max. 100
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
31-5/16”
42-5/32”
34-15/32”
9-9/32”
12-5/8”
26.0
115.0
Yes
Yes
Microprocessor
Equipped
Included
CZ-RD516C
5 Speeds + Auto
24hr Program
Automatic
Automatic
Washable + Anti Microbial Filter
R-410A
Electric Expansion Valve
48 / 40 / 37
53
Flare
1/4”
5/8”
Max. 100
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
11-7/16”
31-5/16”
42-5/32”
34-15/32”
9-9/32”
12-5/8”
26.0
117.0
–
–
E18/22: Tentative spec.
*This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement