Hardware Installation Guide for Cisco UCS E

Add to my manuals
66 Pages

advertisement

Hardware Installation Guide for Cisco UCS E | Manualzz

Hardware Installation Guide for

Cisco UCS E-Series Servers and the

Cisco UCS E-Series Network Compute Engine

First Published: July 15, 2014

Updated: October 12, 2015

This document provides installation information for the Cisco UCS E-Series Servers (E-Series Servers) and the Cisco UCS E-Series Network Compute Engine (NCE). It includes the following sections:

New and Changed Information, page 2

Overview, page 4

Hardware Requirements, page 5

Recommended Safety Practices, page 13

Types of E-Series Servers and NCEs, page 17

E-Series Servers, page 17

EHWIC E-Series NCE, page 48

NIM E-Series NCE, page 56

Removing the COA, page 64

Cisco Integrated Management Controller, page 65

Related Documentation, page 65

Americas Headquarters:

Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA

New and Changed Information

New and Changed Information

The following tables provide an overview of the significant changes that are introduced to this guide in the appropriate software release.

Table 1 New and Changed Information for Software Release 3.0.1

Feature

NIM E-Series Network

Compute Engine

Description

Changed in

Software Release

Support added to install the NIM

E-Series Network Compute Engine

(NIM E-Series NCE) into the Cisco

ISR 4000 series.

3.0.1

Where Documented

“Hardware Information for the NIM E-Series NCE” section on page 11

“NIM E-Series NCE” section on page 56

Table 2

Feature

EHWIC E-Series Network

Compute Engine

New and Changed Information for Software Release 2.4.1

Cisco ISR 4000 Series

Description

Support added to install E-Series

Servers in all Cisco ISR 4000 series.

Changed in

Software Release

Support added to install the

EHWIC E-Series Network

Compute Engine (EHWIC E-Series

NCE) into the Generation 2 Cisco

Integrated Services Routers (Cisco

ISR G2).

2.4.1

2.4.1

Where Documented

“Hardware Information for the EHWIC E-Series NCE” section on page 10

“EHWIC E-Series NCE” section on page 48

“Overview” section on page 4

Table 3

Feature

New and Changed Information for Software Release 2.3.1

Description

Double-Wide E-Series Server refresh

Intel Ivy Bridge 2418L v2 and

2428L v2 support added on the

UCS-E160D-M2 and

UCS-E180D-M2 double-wide

E-Series Servers.

Changed in

Software Release

2.3.1

Where Documented

“Hardware Information for the

M2 E-Series Servers” section on page 8

2

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

New and Changed Information

Table 4 New and Changed Information for Software Release 2.2.1

Feature

SM E-Series Network

Compute Engine

Single-wide E-Series Server refresh

Description

Intel Ivy Bridge E3-1105C V2 support added on the

UCS-E140S-M2 single-side

E-Series Server.

Changed in

Software Release

Support added to install the SM

E-Series Network Compute Engine

(SM E-Series NCE) into the

Generation 2 Cisco Integrated

Services Routers (Cisco ISR G2) and the Cisco ISR 4451-X

Integrated Services Router (Cisco

ISR 4451-X).

2.2.1

2.2.1

Where Documented

“Hardware Information for the

M2 E-Series Servers” section on page 8

“Hardware Information for the

M2 E-Series Servers” section on page 8

Table 5

Feature

New and Changed Information for Software Release 1.0(2)

New Platform Support

Description

Support for installing the E-Series

Server into the Cisco ISR 4451-X.

Changed in

Software Release

1.0(2)

Verifying E-Series Server

Installation

Migrating the E-Series Server from an Cisco ISR G2 into a

Cisco ISR 4000 series

New Online Insertion and

Removal (OIR) command

Command to verify that the router recognizes the E-Series Server.

Special instructions for migrating the E-Series Server from a Cisco

ISR G2 into a Cisco ISR 4000 series.

New OIR command for E-Series

Server installed in a

Cisco ISR 4000 series.

1.0(2)

1.0(2)

1.0(2)

Where Documented

“Overview” section on page 4

“Hardware Requirements” section on page 5

“Verifying E-Series Server or SM

E-Series NCE Installation” section on page 32

“Migrating the E-Series Server from a Cisco ISR G2 into a Cisco

ISR 4000 Series” section on page 33

“Removing the E-Series Server from a Cisco ISR 4000 Series” section on page 37

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

3

Overview

Overview

The Cisco UCS E-Series Servers (E-Series Servers) and the Cisco UCS E-Series Network Compute

Engine (NCE) are a family of size-, weight-, and power-efficient blade servers that are housed within the

Generation 2 Cisco Integrated Services Routers (Cisco ISR G2) and the Cisco ISR 4000 series. These servers provide a general-purpose compute platform for branch-office applications deployed either as bare-metal on operating systems, such as Microsoft Windows or Linux, or as virtual machines on hypervisors, such as VMware vSphere Hypervisor, Microsoft Hyper-V, or Citrix XenServer.

The E-Series Servers are purpose-built with powerful Intel Xeon processors for general-purpose compute. They come in the following form factors: single-wide and double-wide. The single-wide

E-Series Server fits into one server module (SM) slot, and the double-wide E-Series Server fits into two

SM slots.

The NCEs are price-to-power optimized modules that are built to host Cisco network applications and other lightweight general-purpose applications. They come in three form factors: SM, EHWIC, and

NIM. The SM E-Series NCE fits into one SM slot, the NIM E-Series NCE fits into one NIM slot, and the EHWIC E-Series NCE fits into two EHWIC slots.

Figure 1 Types of E-Series Servers and NCEs

Single-Wide E-Series Server Double-Wide E-Series Server

SM E-Series NCE EHWIC E-Series NCE NIM E-Series NCE

Note •

EHWIC E-Series NCE can be installed in the Cisco ISR G2 only.

NIM E-Series NCE can be installed in the Cisco ISR 4000 series only.

The Cisco ISR 4331 has one SM slot. The Cisco ISR 4321 and the Cisco ISR 4431 have no SM slots.

Citrix XenServer is supported on the E-Series Servers only.

4

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Hardware Requirements

Hardware Requirements

Note

E-Series Servers and the SM E-Series NCE can be installed in the Cisco ISR G2 and the

Cisco ISR 4000 series.

The EHWIC E-Series NCE can be installed in the Cisco ISR G2 only.

The NIM E-Series NCE can be installed in the Cisco ISR 4000 series only.

The following M1 E-Series Servers are supported:

UCS-E140S-M1—Single-wide E-Series Server, 4-cores CPU, 1.0-GHz clock speed

UCS-E140D-M1—Double-wide E-Series Server, 4-cores CPU, 2.0-GHz clock speed

UCS-E160D-M1—Double-wide E-Series Server, 6-cores CPU, 1.8-GHz clock speed

UCS-E140DP-M1—Double-wide E-Series Server, 4-cores CPU, with PCIe, 2.0-GHz clock speed

UCS-E160DP-M1—Double-wide E-Series Server, 6-cores CPU, with PCIe, 1.8-GHz clock speed

The following M2 E-Series Servers and SM E-Series NCE are supported:

UCS-EN120S-M2—SM E-Series NCE, 2-cores CPU, 2.0-GHz clock speed

UCS-E140S-M2—Single-wide E-Series Server, 4-cores CPU, 1.8-GHz clock speed

UCS-E160D-M2—Double-wide E-Series Server, 6-cores CPU, 2.0-GHz clock speed

UCS-E180D-M2—Double-wide E-Series Server, 8-cores CPU, 1.8-GHz clock speed

Note

The M1 and M2 E-Series Servers naming terminology indicates different generations of Intel processors within the respective servers.

The following EHWIC E-Series NCE is supported:

UCS-EN120E—EHWIC E-Series NCE, 2-cores CPU, 1.7-GHz clock speed

The following NIM E-Series NCE is supported:

UCS-EN140N-M2—NIM E-Series NCE, 4-cores CPU, 1.7-GHz clock speed

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

5

Hardware Requirements

Hardware Information for the M1 E-Series Servers

Table 6 M1 E-Series Servers Hardware at a Glance

Feature

Form Factor

CPU

CPU Cores and

CPU Clock Speed

UCS-E140S-M1

Single-Wide E-Series Server

Single-wide SM

Intel Xeon

E3-1105C

4-Cores with 1.0-GHz Clock

Speed

UCS-E140D-M1 and

UCS-E160D-M1

Double-Wide E-Series Servers

Double-wide SM

Intel Xeon

E5-2418L and E5-2428L

4-Cores with 2.0-GHz Clock

Speed

6-Cores with 1.8-GHz Clock

Speed

3 Slots

UCS-E140DP-M1 and

UCS-E160DP-M1

Double-Wide E-Series Servers with PCIe

Double-wide SM

Intel Xeon

E5-2418L and E5-2428L

4-Cores with 2.0-GHz Clock

Speed

6-Cores with 1.8-GHz Clock

Speed

3 Slots Memory DIMM

Slots

RAM

RAID

Storage Type

HDD

2 Slots

8 to 16 GB 8 to 48 GB 8 to 48 GB

Supports DDR3 1333-MHz VLP

UDIMM 1.5 V, 4 GB, and 8 GB

RAID 0 and RAID 1

SATA, SAS, SSD, and SED

SAS 10K RPM, SATA 7200 RPM, and SAS SSD Drives

1

Supports DDR3 1333-MHz

RDIMM 1.35 V, 4 GB, 8 GB, and

16 GB

Supports DDR3 1333-MHz

RDIMM 1.35 V, 4-GB, 8-GB, and

16-GB

RAID 0, RAID 1, and RAID 5

SATA, SAS, SSD, and SED

SAS 10K RPM, SATA 7200

RPM, and SAS SSD Drives

1

RAID 0 and RAID 1

SATA, SAS, SSD, and SED

SAS 10K RPM, SATA 7200

RPM, and SAS SSD Drives

1

Supports 3 Drives

200 GB to 3 TB

2 Gigabit Ethernet Interfaces

Supports 2 Drives

200 GB to 2 TB

2 Gigabit Ethernet Interfaces

Supports 2 Drives

Storage Capacity 200 GB to 2 TB

2 Gigabit Ethernet Interfaces Internal Network

Interface

External

Interfaces

1 USB Connector

1 RJ-45 Gigabit Ethernet

Connector

1 Management Port

1 KVM Port (Supports VGA,

1 USB, 1 Serial DB9)

2 USB Connectors

2 RJ-45 Gigabit Ethernet

Connectors

1 Management Port

1 VGA Port

1 Serial DB9

2 USB Connectors

2 RJ-45 Gigabit Ethernet

Connectors

1 Management Port

1 VGA Port

1 Serial DB9

6

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Hardware Requirements

Table 6 M1 E-Series Servers Hardware at a Glance (continued)

Feature

UCS-E140S-M1

Single-Wide E-Series Server

Router Platforms 2911, 2921, 2951, 3925, 3925e,

3945, 3945e, 4331, 4351, 4451-X

2911 ISR G2—1 E-Series Server Maximum

Number of

E-Series Servers per Router

2921 ISR G2—1 E-Series Server

2951 ISR G2—2 E-Series Servers

UCS-E140D-M1 and

UCS-E160D-M1

Double-Wide E-Series Servers

2921, 2951, 3925, 3925e, 3945,

3945e, 4351, 4451-X

2911 ISR G2—None

2921 ISR G2—1 E-Series Server

2951 ISR G2—1 E-Series Server

3925 ISR G2—2 E-Series Servers

Note

3925e ISR G2—2 E-Series

Servers

UCS-E140DP-M1 and

UCS-E160DP-M1

Double-Wide E-Series Servers with PCIe

2921, 2951, 3925, 3925e, 3945,

3945e, 4351, 4451-X

2911 ISR G2—None

2921 ISR G2—1 E-Series Server

2951 ISR G2—1 E-Series Server

The Cisco 2921 and 2951

ISR G2 support 4 cores only.

Note

The Cisco 2921 and 2951

ISR G2 support 4 cores only.

3945 ISR G2—4 E-Series Servers

3945e ISR G2—4 E-Series

Servers

3925 ISR G2—1 E-Series Server

3925e ISR G2—1 E-Series Server

3925 ISR G2—1 E-Series Servers

3925e ISR G2—1 E-Series

Server

ISR 4321—None

ISR 4331—1 E-Series Server

3945 ISR G2—1 E-Series Server

3945e ISR G2—1 E-Series Server

3945 ISR G2—1 E-Series Server

3945e ISR G2—1 E-Series

Server

ISR 4351—2 E-Series Servers

ISR 4431—None

ISR 4321—None

ISR 4331—None

ISR 4451-X—2 E-Series Servers

ISR 4351—1 E-Series Server

ISR 4431—None

ISR 4321—None

ISR 4331—None

ISR 4451-X—1 E-Series Server

ISR 4351—1 E-Series Server

ISR 4431—None

ISR 4451-X—1 E-Series Server

1.

All hardware drives within the E-Series Server must be installed with the same type of storage device: either all SAS drives or all SATA drives.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

7

Hardware Requirements

Hardware Information for the M2 E-Series Servers

Table 7 M2 E-Series Servers and NCE Hardware at a Glance

Feature

Form Factor

CPU

UCS-EN120S-M2

SM E-Series NCE

Single-wide SM

Pentium B925C

UCS-E140S M2

Single-Wide E-Series Server

Single-wide SM

Intel Xeon

UCS-E160D-M2 and UCS-E180D-M2

Double-Wide E-Series Servers

Double-wide SM

Intel Xeon

CPU Cores and CPU

Clock Speed

RAM

2-Cores with 2.0-GHz Clock

Speed

4 to16 GB

Supports DDR3 1333-MHz VLP

UDIMM 1.5 V, 4 GB, and 8 GB

E3-1105C V2

8 to16 GB

Supports DDR3 1333-MHz VLP

UDIMM 1.5 V, 4 GB, and 8 GB

RAID RAID 0 and RAID 1

Storage Type SATA and SAS

HDD SAS 10K RPM, SATA 7200 RPM

Supports 2 Drives

RAID 0 and RAID 1

SATA, SAS, SSD, and SED

SAS 10K RPM, SATA 7200 RPM, and SAS SSD Drives

1

500 GB to 2 TB

Supports 2 Drives

200 GB to 2 TB Storage

Capacity

Internal

Network

Interface

External

Interfaces

2 Gigabit Ethernet Interfaces

1 USB Connector

2 Gigabit Ethernet Interfaces

1 USB Connector

1 RJ-45 Gigabit Ethernet

Connector

1 Management Port

1 RJ-45 Gigabit Ethernet

Connector

1 Management Port

2418L v2 for 6-Cores

2428L v2 for 8-Cores

4-Cores with 1.8-GHz Clock Speed 6-Cores with 2.0-GHz Clock Speed

8-Cores with 1.8-GHz Clock Speed

8 to 48 GB

Supports DDR3 1333-MHz

RDIMM 1.35 V, 4 GB, 8 GB, and

16 GB

RAID 0 and RAID 1

SATA, SAS, SSD, and SED

SAS 10K RPM, SATA 7200 RPM, and SAS SSD Drives

1

Supports 3 Drives

200 GB to 3 TB

2 Gigabit Ethernet Interfaces

2 USB Connectors

2 RJ-45 Gigabit Ethernet

Connectors

1 Management Port

1 KVM Port (Supports VGA,

1 USB, 1 Serial DB9)

1 KVM Port (Supports VGA,

1 USB, 1 Serial DB9)

1 VGA Port

1 Serial DB9

8

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Hardware Requirements

Table 7 M2 E-Series Servers and NCE Hardware at a Glance (continued)

Feature

Router

Platforms

Maximum

Number of

E-Series

Servers or

NCE per

Router

UCS-EN120S-M2

SM E-Series NCE

UCS-E140S M2

Single-Wide E-Series Server

2911, 2921, 2951, 3925, 3925e,

3945, 3945e, 4331, 4351, 4451-X

2911, 2921, 2951, 3925, 3925e,

3945, 3945e, 4331, 4351, 4451-X

2911 ISR G2—1 NCE 2911 ISR G2—1 E-Series Server

2921 ISR G2—1 NCE

2951 ISR G2—2 NCEs

3925 ISR G2—2 NCEs

3925e ISR G2—2 NCEs

2921 ISR G2—1 E-Series Server

2951 ISR G2—2 E-Series Servers

3925 ISR G2—2 E-Series Servers

3925e ISR G2—2 E-Series Servers

UCS-E160D-M2 and UCS-E180D-M2

Double-Wide E-Series Servers

2921, 2951, 3925, 3925e, 3945,

3945e, 4351, 4451-X

2911 ISR G2—None

2921 ISR G2—1 E-Series Server

2951 ISR G2—1 E-Series Server

Note

The Cisco 2921 and 2951

ISR G2 support 6 cores only.

3945 ISR G2—4 NCEs

3945e ISR G2—4 NCEs

ISR 4321—None

ISR 4331—1 NCE

ISR 4351—2 NCEs

ISR 4431—None

ISR 4451-X—2 NCEs

3945 ISR G2—4 E-Series Servers

3945e ISR G2—4 E-Series Servers

ISR 4321—None

ISR 4331—1 E-Series Server

ISR 4351—2 E-Series Servers

ISR 4431—None

ISR 4451-X—2 E-Series Servers

3925 ISR G2—1 E-Series Servers

3925e ISR G2—1 E-Series Server

3945 ISR G2—1 E-Series Server

3945e ISR G2—1 E-Series Server

ISR 4321—None

ISR 4331—None

ISR 4351—1 E-Series Server

ISR 4431—None

ISR 4451-X—1 E-Series Server

1.

All hardware drives within the E-Series Server must be installed with the same type of storage device: either all SAS drives or all SATA drives.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

9

Hardware Requirements

Hardware Information for the EHWIC E-Series NCE

Table 8 EHWIC E-Series NCE Hardware at a Glance

Feature

Form Factor

CPU

CPU Cores and CPU Clock Speed

RAM

RAID

Storage Type

HDD

Storage Capacity

Internal Network Interface

External Interfaces

UCS-EN120E

EHWIC E-Series NCE

Double-wide EHWIC

Intel Atom Processor C2338

2-Cores with 1.7-GHz Clock Speed

4 GB to 8 GB

— mSATA mSATA Flash Drive

50 to 400 GB Formatted

2 Gigabit Ethernet Interfaces

1 Standard USB Connector

1 Mini-USB Connector

1 RJ-45 Gigabit Ethernet Connector

Router Platforms

1 Console Port

1921, 1941, 2901, 2911, 2921, 2951, 3925, 3925e, 3945, 3945e

Maximum Number of NCEs per Router 1921 ISR G2—1 NCE

1941 ISR G2—1 NCE

2901 ISR G2—2 NCEs

2911 ISR G2—2 NCEs

2921 ISR G2—2 NCEs

2951 ISR G2—2 NCEs

3925 ISR G2—2 NCEs

3925e ISR G2—1 NCE

3945 ISR G2—2 NCEs

3945e ISR G2—1 NCE

10

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Hardware Information for the NIM E-Series NCE

Table 9 NIM E-Series NCE Hardware at a Glance

Feature

Form Factor

CPU

CPU Cores and CPU Clock Speed

RAM

RAID

Storage Type

HDD

Storage Capacity

Internal Network Interface

External Interfaces

UCS-EN140N-M2

NIM E-Series NCE

NIM

Intel Atom Processor C2358

4-Cores with 1.7-GHz Clock Speed

8 GB

— mSATA mSATA Flash Drive

32 to 200 GB Formatted

2 Gigabit Ethernet Interfaces

1 USB Connector

1 RJ-45 Gigabit Ethernet Connector

1 Management Port

Router Platforms

1 KVM Port (Supports VGA,

1 USB, 1 Serial DB9)

4321, 4331, 4351, 4431, 4451-X

Maximum Number of NCEs per Router ISR 4321—2 NCEs

ISR 4331—2 NCEs

ISR 4351—3 NCEs

ISR 4431—3 NCEs

ISR 4451-X—3 NCEs

Hardware Requirements

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

11

Hardware Requirements

Supported Cisco EtherSwitch EHWIC and Cisco EtherSwitch Service Modules

The following table shows the Cisco EtherSwitch Enhanced High-Speed WAN Interface Cards

(EHWICs) and Cisco EtherSwitch Service Modules that are supported on the E-Series Server.

Table 10 Supported Cisco EtherSwitch EHWIC and Cisco EtherSwitch Service Modules

Cisco EtherSwitch EHWIC

EHWIC-D-8ESG-P=

EHWIC-D-8ESG-P

EHWIC-D-8ESG=

EHWIC-D-8ESG

EHWIC-4ESG-P=

EHWIC-4ESG-P

EHWIC-4ESG=

EHWIC-4ESG

Cisco EtherSwitch Service Module

SM-ES2-16-P

SM-ES3-16-P

SM-ES3G-16-P

SM-ES2-24

SM-ES2-24-P

SM-ES3-24-P

SM-ES3G-24-P

SM-D-ES2-48

SM-D-ES3-48-P

SM-D-ES3G-48-P

SM-X-ES3-16-P

SM-X-ES3-24-P

SM-X-ES3D-48-P

Supported Transceivers

Table 11 SFP Transceivers Supported on the E100-PCIE10GEFCOE

SFP

SFP-H10GB-CU1M

SFP-H10GB-CU3M

SFP-H10GB-CU5M

Description

SFP+ 10GBASE-CU 1-meter cable, passive

SFP+ 10GBASE-CU 3-meter cable, passive

SFP+ 10GBASE-CU 5-meter cable, passive

SFP-H10GB-ACU7M

SFP-H10GB-ACU10M

SFP+ 10GBASE-CU 7-meter cable, active

SFP+ 10GBASE-CU 10-meter cable, active

JDSU (PLRXPL-SC-S43-22-N) SFP+ SFP+ (Optical)

SFP-10G-SR SFP+ 10GBase-SR (Optical)

12

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Recommended Safety Practices

Recommended Safety Practices

This section describes recommended practices for safe and effective installation of the hardware, and includes the following topics:

Safety Recommendations, page 13

Preventing Electrostatic Discharge Damage, page 14

General Guidelines for Installing the E-Series Servers or the NCE on a Rack, page 14

Maintenance Guidelines, page 14

Safety Warnings, page 15

Safety Recommendations

To prevent hazardous conditions, follow these safety recommendations while working with this equipment:

Keep tools away from walk areas where you or others could fall over them.

Do not wear loose clothing around the router. Fasten your tie or scarf and roll up your sleeves to prevent clothing from being caught in the chassis.

Wear safety glasses when working under any conditions that might be hazardous to your eyes.

Locate the emergency power-off switch in the room before you start working. If an electrical accident occurs, shut the power off.

Before working on the router, turn off the power and unplug the power cord.

Disconnect all power sources before doing the following:

Installing or removing a router chassis

Working near power supplies

Do not work alone if potentially hazardous conditions exist.

Always check that power is disconnected from a circuit.

Remove possible hazards from your work area, such as damp floors, ungrounded power extension cables, or missing safety grounds.

If an electrical accident occurs, proceed as follows:

Use caution; do not become a victim yourself.

Turn off power to the room using the emergency power-off switch.

If possible, send another person to get medical aid. Otherwise, determine the condition of the victim and then call for help.

Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

13

Recommended Safety Practices

Preventing Electrostatic Discharge Damage

Electrostatic discharge can damage equipment and impair electrical circuitry. Electrostatic discharge occurs when electronic printed circuit cards, such as those used in Cisco service modules and network modules, are improperly handled and can result in complete or intermittent equipment failure. Always observe the following electrostatic discharge damage (ESD) prevention procedures when installing, removing, and replacing the E-Series Servers or the NCEs:

Make sure that the router chassis is electrically connected to earth ground.

Wear an ESD-preventive wrist strap, and make sure that it makes good contact with your skin.

Connect the wrist strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

If no wrist strap is available, ground yourself by touching the metal part of the router chassis.

Caution

The wrist strap and clip must be used correctly to ensure proper ESD protection. Periodically confirm that the resistance value of the ESD-preventive wrist strap is between 1 and 10 megohms (Mohm).

General Guidelines for Installing the E-Series Servers or the NCE on a Rack

Excessive vibration can result in the loss of data and disk drive failure. The E-Series Server or NCE with hard disk drives should not be installed in a rack cabinet where it might be exposed to excessive high vibration. Before you install the router and E-Series Server or NCE in the rack cabinet, review the following recommendations:

Note

The E-Series Server or NCE with solid state drives can withstand higher vibration levels.

Install the server away from heating, ventilation, and air-conditioning (HVAC) system, and other large building air movers.

Install the rack away from areas that might be affected by external vibrations, such as a garage that might have moving vehicles, or a factory with heavy machinary.

Do not install the server with rotating hard drives in a rack that will be placed in a moving vehicle.

Maintenance Guidelines

The following maintenance guidelines apply to E-Series Servers and NCEs:

Keep the router chassis area clear and dust-free during and after installation.

If you remove the chassis cover for any reason, store it in a safe place.

Do not perform any action that creates a hazard to people or makes equipment unsafe.

Keep walk areas clear to prevent falls or damage to equipment.

Follow installation and maintenance procedures as documented by Cisco Systems, Inc.

14

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Recommended Safety Practices

Safety Warnings

The following safety warning statements apply to all hardware procedures involving E-Series Servers and NCEs. Translations of these warnings are available in the Cisco Network Modules and Interface

Cards Regulatory Compliance and Safety Information document at: http://www.cisco.com/en/US/docs/routers/access/interfaces/rcsi/IOHrcsi.html

Warning

IMPORTANT SAFETY INSTRUCTIONS

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device.

Statement 1071

SAVE THESE INSTRUCTIONS

Warning

Only trained and qualified personnel should be allowed to install or replace this equipment. Statement

1030

Warning

No user-serviceable parts inside. Do not open. Statement 1073

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

Statement 1040

Warning

Read the installation instructions before connecting the system to the power source. Statement 1004

Warning

Installation of the equipment must comply with local and national electrical codes. Statement 1074

Warning

This unit might have more than one power supply connection. All connections must be removed to

de-energize the unit. Statement 1028

Warning

This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection

authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

Warning

When installing or replacing the unit, the ground connection must always be made first and

disconnected last. Statement 1046

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

15

Recommended Safety Practices

Warning Do not use this product near water; for example, near a bath tub, wash bowl, kitchen sink or laundry

tub, in a wet basement, or near a swimming pool. Statement 1035

Warning Never install telephone jacks in wet locations unless the jack is specifically designed for

wet locations. Statement 1036

Warning Never touch uninsulated telephone wires or terminals unless the telephone line has been

disconnected at the network interface. Statement 1037

Warning Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote

risk of electric shock from lightning. Statement 1038

Warning

To report a gas leak, do not use a telephone in the vicinity of the leak. Statement 1039

Warning

Class 1 laser product. Statement 1008

Warning

Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not view directly with optical instruments. Viewing the laser output with certain optical instruments

(for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye

hazard. Statement 1056

The following warnings apply in Australia:

Warning Do not touch the power supply when the power cord is connected. For systems with a power switch, line voltages are present within the power supply even when the power switch is OFF and the power cord is connected. For systems without a power switch, line voltages are present within the power

supply when the power cord is connected. Statement 4

Warning

This equipment will be inoperable when mains power fails. Statement 198

Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Both

LAN and WAN ports may use RJ-45 connectors. Use caution when connecting cables. Statement 1021

16

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Types of E-Series Servers and NCEs

Warning Hazardous network voltages are present in WAN ports regardless of whether power to the router is

OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching

cables, detach the end away from the router first. Statement 1026

Warning Before opening the chassis, disconnect the telephone-network cables to avoid contact with

telephone-network voltages. Statement 1041

Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260.

Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector or 2)

while the housing is open, or both. Statement 1043

Types of E-Series Servers and NCEs

The following E-Series Servers are available:

Single-wide E-Series Servers. See

E-Series Servers, page 17 .

Double-wide E-Series Servers. See E-Series Servers, page 17 .

The following NCEs are available:

SM E-Series NCE. See

E-Series Servers, page 17

.

The single-wide E-Series Server and the SM E-Series NCE are quite similar.

EHWIC E-Series NCE. See EHWIC E-Series NCE, page 48 .

NIM E-Series NCE. See

NIM E-Series NCE, page 56

.

E-Series Servers

See the following sections for information about the E-Series Servers:

Single-Wide E-Series Servers and the SM E-Series NCE—Front Panel and Components, page 18

Single-Wide E-Series Server and the SM E-Series NCE LEDs, page 21

Double-Wide E-Series Server—Front Panel and Components, page 22

Double-Wide E-Series Server LEDs, page 24

Basic Workflow for Installing the E-Series Server or the SM E-Series NCE in the SM Slot, page 25

Migrating the E-Series Server from a Cisco ISR G2 into a Cisco ISR 4000 Series, page 33

Online Insertion and Removal—E-Series Servers, page 35

Installing or Replacing Hard Disk Drives on the E-Series Servers, page 38

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

17

E-Series Servers

Single-Wide E-Series Servers and the SM E-Series NCE—Front Panel and

Components

The single-wide E-Series Server and the SM E-Series NCE are quite similar. The following figure shows the front panel of the single-wide E-Series Server and the single-wide SM E-Series NCE.

Figure 2 Front Panel of the Single-Wide E-Series Server and the SM E-Series NCE

1

EN

PWR

ACT

HDD1

FLT

2

3 4

KVW

5 6

SYS

ACT

HDD0

FLT

7

USB

RST

8 9 10

1

Gigabit Ethernet port

3

Power switch

5

Keyboard, Video, Mouse (KVM) port

2

Management port

4

LEDs for HDD1

6

Hard disk drive 1

Note

Use the KVM connector that is shipped with the E-Series Server. See

Figure 3 .

7

LEDs for HDD0

8

USB

9

Hard disk drive 2 10 Reset switch

18

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

The following figure shows the KVM connector that is shipped with the single-wide E-Series Server and the single-wide NCE.

Figure 3 KVM Connector

3

2

1

1

USB connector

3

DB9 connector—serial port

2

DB15 connector—video port

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

19

E-Series Servers

The following figure shows the internal components of the single-wide E-Series Server.

Figure 4 Internal Components of the Single-Wide E-Series Server

5

4

3

1

2

2

1

Memory DIMM slots

3

SD0

Note

The SD0 card contains the Cisco

Integrated Management Controller

(CIMC) software and must always be present.

2

HDD

4

SD1

Note

The SD1 card is interfaced directly to the Intel server.

Caution

Do not swap SD cards between

UCS E-Series Servers. See the

“Recovering from a Faulty SD

Card” section in the CLI

Configuration Guide for the Cisco

UCS E-Series Servers and the

Cisco UCS E-Series Network

Compute Engine Integrated

Management Controller.

5

CMOS battery (located under the hard drive tray)

20

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Single-Wide E-Series Server and the SM E-Series NCE LEDs

The following table lists the single-wide E-Series Server and the SM E-Series NCE LEDs and describes the LED colors and states.

Table 12 Single-Wide E-Series Server and SM E-Series NCE LEDs

LED Color

HDD 0 ACT Green

State

Status of the hard drive activity:

Steady—Hard drive is present.

Blinking—Active.

Off—Inactive or there is no power supplied to the CPU.

HDD0 FLT

Amber The CPU is in use. Fault is detected on the hard drive.

HDD1 ACT

Green

Note

The SYS LED displays solid green.

Status of the hard drive activity:

Steady—Hard drive is present.

Blinking—Active.

Off—Inactive or there is no power supplied to the CPU.

HDD1 FLT

Amber The CPU is in use. Fault is detected on the hard drive.

SYS

Green

Note

The SYS LED displays solid green.

Status can be one of the following:

Solid—Operation is normal.

Note

If DRAM is not detected, the SYS LED still displays solid green.

Power

GE Port

LEDs

Blinking—System is booting before entering the EFI shell.

Amber Fault is detected on the processor.

Green Status can be one of the following:

Steady—CIMC and CPU are both operating normally.

Blinking—CPU is operating normally, and CIMC is booting up.

Amber Status can be one of the following:

Green

Green

Steady—CIMC is operating normally, and the CPU is powered down.

Blinking —CIMC is in the process of booting up, and the CPU is powered down.

Left LED shows the speed of the Ethernet cable:

1 Blink—10 Mb/s speed.

2 Blinks—100 Mb/s speed.

3 Blinks—1 Gb/s speed.

Right LED shows whether the link is established:

Steady—Link is established.

Off—No link is established.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

21

E-Series Servers

Double-Wide E-Series Server—Front Panel and Components

Figure 5 Front Panel of the Double-Wide E-Series Server

8

UCS-EXXX-K9-MX

PWR RST

M0

M1

M2

HOT

D0F

D0A

D1F

D1A

D2F

D2A

ACT

STS

VGA

1

9

SERIAL

SD1

SD0

GE3

GE2

1

0

IMC EN

HDD2

1

2

3 4 5 6 7 9

10 11

HDD1

HDD0

1

Power switch

3

LEDs

5

Serial port

13 12

2

Reset switch

Note

This resets all CMOS settings.

4

VGA port

6

Dual SD card slots and cover

Note

The SD0 card is located in the bottom slot. The SD0 card contains the CIMC software and should always be present.

22

Caution

Do not remove the SD0 card when the system is in operation.

Note

The SD1 card is located in the top slot.

The SD1 card is interfaced directly to the Intel server.

Caution

Do not swap SD cards between

UCS E-Series Servers. See the

“Recovering from a Faulty SD

Card” section in the CLI

Configuration Guide for the Cisco

UCS E-Series Servers and the

Cisco UCS E-Series Network

Compute Engine Integrated

Management Controller.

8

Management port

7

Gigabit Ethernet ports (GE2 and GE3)

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Figure 6

9

USB ports

Each port provides up to 500 mA of current.

Devices that require higher power, such as

CD/DVD ROM, need their own external power.

11 Hard disk drives (HDD0 and HDD1)

10 (Optional) HDD2, PCIe assembly or blank slot

12 (Optional) Alternate PCIe assembly with

FCoE port

Note

Use with PCIe assembly modules only.

13 (Optional) Alternate PCIe assembly with

4 Gigabit Ethernet ports

Note

Use with PCIe assembly modules only.

Internal Components of the Double-Wide E-Series Server

1 2

3

4

1

Memory DIMM slots

3

(Optional) PCIe assembly

Available for HDD2, FCoE port, or 4 Gigabit Ethernet ports.

2

CMOS battery (resides inside the battery protector)

4

Hard disk drives (HDD0 and HDD1)

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

23

E-Series Servers

Double-Wide E-Series Server LEDs

The following table lists the double-wide E-Series Server LEDs and describes the LED colors and states.

Table 13 Double-Wide E-Series Server LEDs

LED

M0

1

M1

2

M2

3

HOT

D0A

D0F

D1A

D1F

D2A

D2F

ACT

STS

IMC

Color

Off

Green

Amber

Off

Green

Amber

Off

Green

Amber

Green

Amber

Green

Amber

Green

Amber

Green

Amber

Green

Green

Amber

Green

State

No memory is installed in this socket.

Memory M0 is installed.

Memory M0 is installed, but fault is detected.

No memory installed in this socket.

Memory M1 is installed.

Memory M1 is installed, but fault is detected.

No memory is installed in this socket.

Memory M2 is installed.

Memory M2 is installed, but fault is detected.

Temperature is in range.

High temperature is detected on the CPU, power supply, or other internal sensors.

Status of the hard drive activity:

• Steady—Hard drive is present.

• Blinking—Activity.

• Off—Inactive or there is no power supplied to the CPU.

Fault is detected on the hard drive.

Status of the hard drive activity:

• Steady—Hard drive is present.

• Blinking—Active.

• Off—Inactive or there is no power supplied to the CPU.

Fault is detected on the hard drive.

If an optional hard drive is present, the status of the hard drive activity can be one of the following:

Steady—Hard drive is present.

Blinking—Active.

Off—Inactive or there is no power supplied to the

CPU.

If there is a PCIe card installed, the LED is steady green.

Fault is detected on the hard drive.

Blinks when the processor is active.

Operation is normal.

Fault is detected on the processor.

Blinks when the CIMC is operating normally.

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

24 OL-26447-04

E-Series Servers

Table 13

LED

Power

GE Port LEDs

Double-Wide E-Series Server LEDs (continued)

Color

Green

Amber

Green

Green

State

Steady—CIMC and the CPU are both operating normally.

Blinking—The CPU is operating normally, and

CIMC is booting up.

Steady—CIMC is operating normally, and the CPU is powered down.

Blinking—CIMC is in the process of booting up, and the CPU is powered down.

Left LED shows the speed of the Ethernet cable:

1 Blink—10 Mb/s speed.

2 Blinks—100 Mb/s speed.

3 Blinks—1 Gb/s speed.

Right LED shows whether the link is established.

Steady—Link is established.

Off—No link is established.

1.

This is memory installed on the DIMM 0 slot.

2.

This is the DIMM 1 slot.

3.

This is the DIMM 2 slot.

Basic Workflow for Installing the E-Series Server or the SM E-Series NCE in the

SM Slot

Step 1

Step 2

Step 3

Step 4

Step 5

Action

Gather the required tools and equipment.

Remove the blank faceplates from the SM slots that you want to use.

Depending on the type of server that you want to install either remove or install the slot divider.

Install the E-Series Server or SM E-Series NCE into the router.

Verify the E-Series Server or SM E-Series NCE installation.

Reference Topic

“Tools and Equipment Required for Installation” section on page 26

“Removing the Blank Faceplate from the Router’s

SM Slot” section on page 26

“Preparing the Router’s SM Slot for E-Series

Server or SM E-Series NCE Installation” section on page 27

“Installing the E-Series Server or the SM E-Series

NCE into the Router” section on page 29

“Verifying E-Series Server or SM E-Series NCE

Installation” section on page 32

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

25

E-Series Servers

Tools and Equipment Required for Installation

Number-1 Phillips screwdriver or a small flat-blade screwdriver

ESD-preventive wrist strap

Tape to secure DC circuit breaker handle—Applicable for routers that use DC power

Removing the Blank Faceplate from the Router’s SM Slot

Warning

Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not

operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement

1029

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Using either a number-1 Phillips screwdriver or a small flat-blade screwdriver, unscrew the captive screws and remove the blank faceplate from the chassis slot.

Figure 7 Blank Faceplate

T REMO

VE DURING

TION

DO NO

T REMO

TION

Step 2

Save the blank faceplates for future use.

What to Do Next

Prepare the router slot for E-Series Server or SM E-Series NCE installation. See the “Preparing the

Router’s SM Slot for E-Series Server or SM E-Series NCE Installation” section on page 27 .

26

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Preparing the Router’s SM Slot for E-Series Server or SM E-Series NCE Installation

Several Cisco routers have flexible SM slots to support various Cisco server modules. Before installing the E-Series Server or SM E-Series NCE into the router, prepare the router’s SM slot for the server’s particular form factor.

Slot dividers are used on the following routers:

Cisco 2921, and 2951 series ISR G2

Cisco 3925, 3925e, 3945, and 3945e ISR G2

By default, the slot dividers are preinstalled in the router. Depending on the type of server that you want to install, you must either install or remove the slot divider from the router.

Note •

To replace a double-wide E-Series Server with a single-wide E-Series Server or SM E-Series NCE, you must install a slot divider.

To install the double-wide E-Series Server, you must remove the slot divider.

Figure 8 Slot Divider for SM Slots

See the following topics for more information:

Installing a Slot Divider for Single-Wide E-Series Servers or SM E-Series NCE Installation, page 27

Removing the Slot Divider for Double-Wide E-Series Server Installation, page 29

Installing a Slot Divider for Single-Wide E-Series Servers or SM E-Series NCE Installation

By default, the slot dividers are preinstalled in the router. To replace a double-wide E-Series Server with a single-wide E-Series Server or SM E-Series NCE, you must install a slot divider. Use this procedure to install a slot divider for a single-wide E-Series Server or a SM E-Series NCE.

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

27

E-Series Servers

Procedure

Step 1

Step 2

Remove any installed modules, blank faceplates, and slot adapters from the router slot that you want to use.

Insert the top rails of the slot divider between the two guide rails in the top of the module slot.

Figure 9 Inserting a Slot Divider into an SM Slot

DO NO

T REMO

NETWORK OPERA

TION

DO NO

T REMO

NETWORK OPERA

TION

Step 3

Step 4

Push the slot divider in until it is fully seated. Slot dividers have a long retention screw that slides into the divider. See the figure above.

Tighten the retention screw on the front of the slot divider with a number-1 Phillips screw driver so that the front surface of the slot divider is flush with the router panel.

Figure 10 Tightening the Slot Divider in an SM Slot

T REMO

VE DURING

TION

T REMO

VE DURING

TION

What to Do Next

Install the E-Series Server or SM E-Series NCE into the router. See the “Installing the E-Series Server or the SM E-Series NCE into the Router” section on page 29

.

28

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Removing the Slot Divider for Double-Wide E-Series Server Installation

To install a double-wide E-Series Server in the SM slot, you must remove the slot divider. Use this procedure to remove the slot dividers from the SM slot.

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Step 2

Step 3

Remove any installed service modules, blank faceplates, and slot adapters from the router slot that you plan to use.

Loosen the retention screw on the front of the slot divider.

Pull the slot divider straight out of the module slot.

What to Do Next

Install the E-Series Server into the router. See the “Installing the E-Series Server or the SM E-Series

NCE into the Router” section on page 29 .

Installing the E-Series Server or the SM E-Series NCE into the Router

E-Series Servers or the SM E-Series NCE can be installed either before or after mounting the router, whichever is more convenient.

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Statement 1030

Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some

LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Statement 1021

Warning Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables,

detach the end away from the unit first. Statement 1026

Caution

To prevent damage to the server, handle the server by the chassis or frame.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

29

E-Series Servers

Before You Begin

Verify that you have done the following:

1.

Removed the blank faceplates from the slots that you intend to use. See the

“Removing the Blank

Faceplate from the Router’s SM Slot” section on page 26

.

2.

3.

4.

Saved the blank faceplates for future use.

Prepared the slot for the module form factor that you are installing. See the “Preparing the Router’s

SM Slot for E-Series Server or SM E-Series NCE Installation” section on page 27 .

Connected a wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Note

For the Cisco 3900 ISR G2—If you are using PoE, and you want to install one double-wide E-Series

Server and any number of server modules in a Cisco 3900 ISR G2, you must use a second AC and PoE supply to support this configuration.

For example, if you have a Cisco 3900 ISR G2 that has a PoE-capable switch providing power to phones, and you want to install a double-wide E-Series Server in one slot and one or two single-wide servers in the other slots, then you must use a second AC and PoE supply to support this configuration.

Procedure

Step 1

Turn off the electrical power to the router. Leave the power cable plugged in to the channel ESD voltages to ground.

Figure 11

Note

Alternatively, the Cisco 3900 ISR G2 and the Cisco ISR 4000 series support OIR. See the

“Online Insertion and Removal—E-Series Servers” section on page 35

.

Step 2

Align the module with the guides in the chassis walls or slot divider and slide the module gently into the slot. See the following figures:

Installing a Single-Wide E-Series Server or SM E-Series NCE in a Cisco ISR G2

1

1

Single-wide E-Series Server

3

Router chassis

2

2

Slot divider

3

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

30 OL-26447-04

E-Series Servers

Figure 12 Installing a Double-Wide E-Series Server in a Cisco ISR G2

AUX

CF 1 CF 0 ISN PVDM 3 PVDM 2 PVDM 1 PVDM 0 EN EN

CONSOLE

GE 0/2

GE 0/1

UCS-EXXX-K9-MX

PWR RST

M0

M1

M2

HOT

D0F

D0A

D1F

D1A

D2F

D2A

ACT

STS

VGA

1

9

SERIAL

SD1

SD0

GE3

GE2

1

0

IMC EN

HDD2

HDD1

HDD0

1 2

1

Double-wide E-Series Server

2

Router chassis

Step 3

Push the module into place until you feel the module seat securely into the connector on the router backplane. The module faceplate should contact the chassis rear panel.

Tip

When installing the E-Series Server into a Cisco ISR 4000 series, if the module does not completely slide into the router, push the module slightly upwards, and then inward to complete the insertion.

Step 4

Using a number-1 Phillips or flat-blade screwdriver, tighten the captive mounting screws on the module faceplate.

What to Do Next

1.

Load a compatible Cisco IOS image. See the “Cisco ISR G2, E-Series Server, NCE, and Cisco IOS

Software Release Compatibility” section in the Release Notes for Cisco UCS E-Series Servers and

the Cisco UCS E-Series Network Compute Engine, Release 3.x.

2.

Connect the E-Series Server or SM E-Series NCE to the network and then power up the router and the server.

3.

4.

Install blank faceplates to cover any open slots. See the “Installing the Blank Faceplate” section on page 31

.

Verify that the router recognizes the E-Series Server or SM E-Series NCE. See the

“Verifying

E-Series Server or SM E-Series NCE Installation” section on page 32

.

Installing the Blank Faceplate

All empty chassis slots on the router must be covered with blank faceplates to ensure proper cooling and airflow and to prevent electromagnetic interference. Use this procedure to install a blank faceplate on the router’s SM slot.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

31

E-Series Servers

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Install the blank faceplate as shown in the figure below.

For blank faceplates with mounting screws—Align the captive screws with the screw holes on the chassis. Using either a number-1 Phillips screwdriver or a small flat-blade screwdriver, tighten the captive screws until the blank faceplate is flush with the chassis.

For blank faceplates with tabs—Align the blank faceplate tabs with the slots on the chassis. Press the blank faceplate against the chassis until the tabs pop into place. When installed, make sure that the blank faceplate is flush with the chassis.

Figure 13 Blank Faceplate

DO NO

T REMO

NETWORK OPERA

TION

DO NO

T REMO

TION

Verifying E-Series Server or SM E-Series NCE Installation

Before You Begin

1.

Install the E-Series Server or SM E-Series NCE into the router.

2.

Load a compatible Cisco IOS image.

3.

Power on the server.

32

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Procedure

To verify the E-Series Server or SM E-Series NCE installation, use one of the following commands:

To display a high-level overview of the entire physical system, use the show platform command:

Router# show platform

Chassis type: ISR4451/K9

Slot Type State Insert time (ago)

--------- ------------------- ---------------------

0 ISR4451/K9 ok 1d01h

0/0 ISR4400-4X1GE ok 1d01h

1 ISR4451/K9 ok 1d01h

1/0 UCS-E160DP-M1/K9 ok 1d01h

2 ISR4451/K9 ok 1d01h

R0 ISR4451/K9 ok, active 1d01h

F0 ISR4451/K9 ok, active 1d01h

P0 XXX-XXXX-XX ok 1d01h

P1 Unknown ps, 1d01h

P2 ACS-4450-FANASSY ok 1d01h

Slot CPLD Version Firmware Version

--------- ------------------- ---------------------

0 12090323 12.2(20120829:165313)

1 12090323 12.2(20120829:165313)

2 12090323 12.2(20120829:165313)

R0 12090323 12.2(20120829:165313)

F0 12090323 12.2(20120829:165313)

To verify that the router recognizes the server, use the show hw-module subslot all oir command:

Router# show hw-module subslot all oir

Module Model Operational Status

------------- -------------------- -----------------------subslot 0/0 ISR4451-X-4X1GE ok subslot 1/0 UCS-E140S-M1/K9 ok subslot 2/0 UCS-E140S-M1/K9 ok

Migrating the E-Series Server from a Cisco ISR G2 into a Cisco ISR 4000 Series

If you are migrating the E-Series Server from a Cisco ISR G2 into a Cisco ISR 4000 series, you must first upgrade the CIMC and the BIOS firmware image to the latest version—while the E-Series Server is still installed in the Cisco ISR G2—and then migrate it into the Cisco ISR 4000 series. We strongly recommend that you upgrade both the CIMC and the BIOS firmware images.

You can use either the Cisco Host Upgrade Utility (HUU) to upgrade the firmware components or you can upgrade the firmware components manually. For firmware upgrade information, see the “Upgrading

Firmware” chapter in the Getting Started Guide for Cisco UCS E-Series Server Modules and the Cisco

UCS E-Series Network Compute Engine Integrated Management Controller on Cisco.com.

If you migrate the E-Series Server into the Cisco ISR 4000 series without first updating the CIMC firmware, the E-Series Server might continuously reset. To stop the reset and install the firmware, see the

“Stopping the E-Series Server from Resetting and Updating the CIMC Firmware” section on page 34

.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

33

E-Series Servers

Stopping the E-Series Server from Resetting and Updating the CIMC Firmware

If you migrate the E-Series Server into the Cisco ISR 4000 series without first updating the CIMC firmware, the E-Series Server might continuously reset. Use this procedure to stop the reset and install the firmware.

Note

Some of the steps in this procedure are performed from the router, and other steps are performed from the E-Series Server.

DETAILED STEPS

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Command or Action

Router# hw-module subslot slot/subslot

maintenance enable

Purpose

Disables error recovery, which stops the E-Series Server from being reset.

Note

Enter the commands in Step 1 and Step 2 from the router.

Router# hw-module subslot slot/subslot session imc Starts a CIMC session.

Server# scope cimc From the CIMC CLI, enters the CIMC command mode.

Server/cimc# scope firmware

Server/cimc/firmware# update tftp-ip-address

path-and-filename

Server/cimc/firmware# show [detail]

Note

Enter the commands in Step 3 through Step 8 from the E-Series Server.

Enters the CIMC firmware command mode.

Starts the CIMC firmware update. The server will obtain the update firmware at the specified path and file-name from the TFTP server at the specified IP address.

Displays the available firmware and status.

Step 7

Server/cimc/firmware# activate [1 | 2]

Step 8

Step 9

Click Ctrl a Ctrl q.

Router# hw-module subslot slot/subslot

maintenance disable

Step 10

Router# hw-module subslot slot/subslot reload

Caution

Make sure that the upgrade process displays

100% before moving to step 7.

Activates the selected image. If no image number is specified, the server activates the currently inactive image.

Exits the CIMC session.

Enables error recovery.

Note

Enter the commands in Step 9 and Step 10 from the router.

Reloads the E-Series Server.

Note

This reload power-cycles the E-Series Server.

34

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Online Insertion and Removal—E-Series Servers

Online insertion and removal (OIR) provides uninterrupted network operation, maintains routing information, and ensures session preservation on the Cisco 3900 series ISR G2 and the Cisco ISR 4000 series. You can use online insertion and removal to install or replace hardware without affecting system operations.

Note

OIR is not supported on the EHWIC E-Series NCE.

Note

The Cisco 2900 series ISR G2 does not support OIR of the E-Series Servers.

To avoid damaging the router, turn off the electrical power on the router and disconnect network cables before inserting or removing the E-Series Server from the Cisco 2900 ISR G2.

The OIR commands for the Cisco 3900 series ISR G2 and the Cisco ISR 4000 series are different. See the following topics for more information:

Removing the E-Series Server from a Cisco 3900 Series ISR G2, page 35

Removing the E-Series Server from a Cisco ISR 4000 Series, page 37

Removing the E-Series Server from a Cisco 3900 Series ISR G2

Shutting Down the E-Series Server Installed in a Cisco 3900 Series ISR G2, page 35

Restarting the E-Series Server Installed in a Cisco 3900 Series ISR G2, page 36

Inserting the E-Series Server in a Cisco 3900 Series ISR G2, page 36

Shutting Down the E-Series Server Installed in a Cisco 3900 Series ISR G2

SUMMARY STEPS

1.

2.

3.

enable

ucse slot

shutdown

or

ucse subslot slot/port-adapter shutdown

hw-module sm slot oir-stop

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

35

E-Series Servers

DETAILED STEPS

Command or Action

Step 1 enable

Example:

Router> enable

Step 2 ucse

slot

shutdown

or

ucse subslot

slot/port-adapter shutdown

Example:

Router# ucse 4 shutdown

Step 3 hw-module sm

slot

oir-stop

Example:

Router# hw-module sm 4 oir-stop

SM Hardware slot 4 can be removed

Purpose

Enables privileged EXEC mode.

Enter your password if prompted.

Shuts down the E-Series Server gracefully.

ucse slot shutdown command is applicable from Cisco

IOS Release 15.2(4)M to 15.4(2)T.

ucse subslot slot/port-adapter shutdown command is applicable from Cisco IOS Release 15.4 (3)M.

Note

Before proceeding with the next command, verify that the E-Series Server has shut down. When the

E-Series Server shuts down, the power LED turns orange. You can also use CIMC to verify if the

E-Series Server has powered down.

Shuts down power to the specified E-Series Server to prepare it for removal.

When it is safe to remove the E-Series Server, a message is displayed as shown in the example.

Note

Before removing the E-Series Server, verify that power to the slot is shut down. The power LED should be off.

Restarting the E-Series Server Installed in a Cisco 3900 Series ISR G2

If the oir-stop command is issued and the E-Series Server is not physically removed from the slot, you can restart the E-Series Server with the oir-start command. From a console terminal, issue the

hw-module sm slot oir-start command. The console displays the module’s changing state.

Example:

Router# hw-module sm 2 oir-start

Router#

*Mar 8 05:40:19.195: %LINK-3-UPDOWN: Interface ucse2/0, changed state to up

*Mar 8 05:40:20.195: %LINEPROTO-5-UPDOWN: Line protocol on Interface ucse2/0, changed state to up

Inserting the E-Series Server in a Cisco 3900 Series ISR G2

The Cisco 3900 ISR G2 that is up and running can detect when an E-Series Server is inserted in the SM slot and will automatically provide power to the server.

36

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Removing the E-Series Server from a Cisco ISR 4000 Series

Shutting Down the E-Series Server Installed in a Cisco ISR 4000 Series, page 37

Restarting the E-Series Server Installed in a Cisco ISR 4000 Series, page 38

Inserting the E-Series Server in a Cisco ISR 4000 Series, page 38

Shutting Down the E-Series Server Installed in a Cisco ISR 4000 Series

SUMMARY STEPS

1.

2.

3.

enable

ucse subslot slot/0 shutdown

hw-module subslot slot/0 stop

DETAILED STEPS

Command or Action

Step 1 enable

Purpose

Enables privileged EXEC mode.

Enter your password if prompted.

Example:

Router> enable

Step 2 ucse subslot

slot

/0 shutdown

Example:

Router# ucse subslot 1/0 shutdown

Step 3 hw-module subslot

slot

/0 stop

Example:

Router# hw-module subslot 1/0 stop

SM Hardware slot 0 can be removed

Shuts down the E-Series Server gracefully.

Note

Before proceeding with the next command, verify that the E-Series Server has shut down. When the

E-Series Server shuts down, the power LED turns orange. You can also use CIMC to verify if the

E-Series Server has powered down.

Shuts down power to the specified E-Series Server to prepare it for removal.

When it is safe to remove the E-Series Server, a message is displayed as shown in the example.

Note

Before removing the E-Series Server, verify that power to the slot is shut down. The power LED should be off.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

37

E-Series Servers

Restarting the E-Series Server Installed in a Cisco ISR 4000 Series

If the oir-stop command is issued and the E-Series Server is not physically removed from the slot, you can restart the E-Series Server with the start command. From a console terminal, issue the

hw-module subslot slot/0 start command. The console displays the module’s changing state.

Example:

Router# hw-module subslot 1/0 start

Inserting the E-Series Server in a Cisco ISR 4000 Series

A Cisco ISR 4000 series that is up and running can detect when an E-Series Server is inserted in the SM slot. After the router detects the E-Series Server, the router software enables power to the server.

Installing or Replacing Hard Disk Drives on the E-Series Servers

The double-wide E-Series Servers can be ordered with two or three hard disk drives (HDD) or solid-state drives (SSD) preinstalled. The double-wide E-Series Servers support the following Redundant Array of

Independent Disks (RAID) configuration:

RAID 0 (data striping)—Data is stored evenly in stripe blocks across all disks in the array, providing fast throughput. There is no data redundancy, and all data is lost if any disk fails.

RAID 1 (disk mirroring)—Data is written to two disks, where the data in both disk drives is identical. This provides complete data redundancy if one disk fails.

RAID 5 (disk striping with distributed parity)—Data and parity information is striped and distributed across all disks in the array with distributed parity information. RAID 5 requires three hard disks and provides limited fault tolerance.

The double-wide E-Series Servers support adding a hot spare drive under RAID 1. If one of the disk drives under RAID 1 fails and there is a hot spare drive installed, the system automatically rebuilds the disk image onto the hot spare drive. The hot spare drive replaces the failed drive as the mirrored drive under RAID 1. To maintain fault tolerance, you must install another hard disk drive.

The single-wide E-Series Servers and the SM E-Series NCE come with two HDDs or SSDs preinstalled.

The single-wide E-Series Servers and the SM E-Series NCE support RAID 0 and RAID 1.

The EHWIC E-Series NCE comes with one SSD preinstalled. The EHWIC E-Series NCE does not support RAID.

Warning

Only trained and qualified personnel should be allowed to install or replace this equipment.

Statement 1030

Warning

Ultimate disposal of this product should be handled according to all national laws and regulations.

Statement 1040

Warning

No user-serviceable parts inside. Do not open. Statement 1073

38

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Warning This unit might have more than one power supply connection. All connections must be removed to

de-energize the unit. Statement 1028

Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place.

Statement 1029

Note

The hard disk drives must be installed in the following order:

1.

2.

3.

HDD0

HDD1

HDD2

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Use this procedure to install or replace a hard disk drive on the E-Series Servers.

Step 1

Turn off power to the router.

Note

Alternatively, the Cisco 3900 ISR G2 and the Cisco ISR 4000 series support OIR. See the

“Online Insertion and Removal—E-Series Servers” section on page 35 .

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

39

E-Series Servers

Step 2

Using either a number-1 Phillips screwdriver or a small flat-blade screwdriver, unscrew the captive screws on the faceplate and remove the cover faceplate. See the following figures.

Figure 14 Replacing a Hard Disk Drive on the Single-Wide E-Series Server

1

Captive screws

2

1

2

Hard disk drive assembly

40

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Figure 15 Replacing a Hard Disk Drive on the Double-Wide E-Series Server

E-Series Servers

4

3

2

UCS-EXXX-K9-MX

PWR RST

M0

M1

M2

HOT

D0F

D0A

D1F

D1A

D2F

D2A

ACT

STS

VGA

1

9

SERIAL

SD1

SD0

GE3

GE2

1

0

IMC EN

HDD2

1

HDD1

HDD0

1

Hard disk drive

3

Cover faceplate

2

Hard disk drive assembly

4

Captive screws on hard disk drive assembly

Step 3

(Optional) If the slot is empty, use the screwdriver to loosen the screws on the bracket, and then remove the bracket (see the following figure). Go to

Step 6

.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

41

E-Series Servers

Figure 16 Empty HDD2 Slot

2

1

1

Bracket

2

Captive screws on hard disk drive assembly

Step 4

Step 5

Step 6

Step 7

Step 8

Step 9

Step 10

(Optional) If there is a hard disk drive, use the screwdriver to loosen the captive screws on the hard disk drive assembly.

(Optional) To remove the faulty hard disk, pull the handle of the hard disk drive assembly and slide out the hard disk drive.

Slide the new hard disk drive into the E-Series Server until it clicks into place.

Tighten the captive screws on the new hard disk drive assembly. Make sure that the HDDs are firmly secure to the carrier to avoid rattling during operation.

Replace the faceplate.

Restart the E-Series Server.

Configure the new HDD as the new hotspare disk drive. For the configuration procedure, see the GUI

Configuration Guide for UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

Integrated Management Controller.

42

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Installing and Replacing the Memory DIMMS in the E-Series Servers

Note

You cannot replace the memory DIMM in an EHWIC E-Series NCE. If you encounter a problem with the memory DIMM, you must replace the entire EHWIC E-Series NCE.

Caution

Always wear an ESD-preventive wrist strap and ensure that it makes good contact with your skin when you remove or install DIMMs. Connect the equipment end of the wrist strap to the metal part of the chassis.

Caution

Handle the DIMMs by the edges only. DIMMs are ESD-sensitive components and can be damaged by mishandling.

Warning Only trained and qualified personnel should be allowed to install or replace this equipment.

Statement 1030

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

Statement 1040

Warning

No user-serviceable parts inside. Do not open. Statement 1073

Warning

This unit might have more than one power supply connection. All connections must be removed to

de-energize the unit. Statement 1028

Warning

Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place.

Statement 1029

This section includes the following topics:

Memory DIMM Location, page 44

Removing the Memory DIMM, page 45

Installing the Memory DIMM, page 46

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

43

E-Series Servers

Memory DIMM Location

The following figure shows the location of the memory DIMMs in a single-wide E-Series Server.

Note

The single-wide E-Series Servers support up to 16 GB of DDR3 memory DIMMs.

Figure 17 Memory DIMM Location in a Single-Wide E-Series Server

Node0_Dimm1

Node0_Dimm0

44

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

The following figure shows the location of the memory DIMMs in a double-wide E-Series Server.

Note

The double-wide E-Series Servers support up to 48 GB of DDR3 memory DIMMs.

Figure 18 Memory DIMM Location in a Double-Wide E-Series Server

Node0_Dimm2

Node0_Dimm1

Node0_Dimm0

Removing the Memory DIMM

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Turn off power to the router.

Note

Alternatively, the Cisco 3900 ISR G2 and the Cisco ISR 4000 series support OIR. See the

“Online Insertion and Removal—E-Series Servers” section on page 35 .

Step 2

Locate the DIMM on the E-Series Server. See the “Memory DIMM Location” section on page 44 .

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04 45

E-Series Servers

Step 3

Pull the latches away from the DIMM at both ends to lift the DIMM slightly.

Caution

Take care not to dislodge the battery that is adjacent to the DIMM connectors.

Step 4

Pull the DIMM out of the socket as shown in the following figure.

Figure 19 Removing the Memory DIMM

Step 5

Place the DIMM in an antistatic bag to protect it from ESD damage.

Installing the Memory DIMM

For information about the memory on the router, see the appropriate router documentation. For information about the memory on the E-Series Server, see the requirements of the installed operating system.

Note

The single-wide E-Series Servers support up to 16 GB of DDR3 memory DIMMs.

The double-wide E-Series Servers support up to 48 GB of DDR3 memory DIMMs.

Performance degradation can occur if you use the following memory configuration:

Mix DIMM sizes and densities within a channel.

Partially populate a channel.

Unevenly populate the DIMMs between CPUs.

46

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

E-Series Servers

Note

DIMMs must be installed in the following order in the double-wide E-Series Servers:

1.

DIMM 1 (center DIMM)

2.

3.

DIMM 2 (closest to the CPU)

DIMM 0 (outboard DIMM)

Note

DIMMs must be installed in the following order in the single-wide E-Series Servers:

1.

2.

DIMM 0 (closest to the CPU)

DIMM 1 (outboard DIMM)

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Turn off power to the router.

Note

Alternatively, the Cisco 3900 ISR G2 and the Cisco ISR 4000 series support OIR. See the

“Online Insertion and Removal—E-Series Servers” section on page 35 .

Step 2

Locate the DIMM connector. See the

“Memory DIMM Location” section on page 44 .

Note

The DIMM connectors on the double-wide E-Series Servers are positioned at an angle; therefore, make sure that you insert the DIMM at approximately the same angle.

Step 3

Step 4

Make sure that both latches on the DIMM connector are in the open position.

Orient the DIMM so that the polarization notch on the DIMM lines up with the notch on the connector.

Figure 20 Polarization Notch on the DIMM

1

1

Polarization notch

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

47

EHWIC E-Series NCE

Step 5

Step 6

Insert the DIMM into the connector.

Carefully and firmly press the DIMM into the connector until the latches close onto the DIMM. Make sure that both latches snap to the closed position against the DIMM.

Figure 21 Installing a Memory DIMM

Step 7

Replace the E-Series Server.

EHWIC E-Series NCE

See the following sections for more information about EHWIC E-Series NCE:

EHWIC E-Series NCE—Front Panel and Components, page 49

EHWIC E-Series NCE LEDs, page 50

Basic Workflow for Installing the EHWIC E-Series NCE in the EHWIC Slot, page 50

Online Insertion and Removal—EHWIC E-Series NCE, page 55

Installing the Field Programmable Gate Array Image in the EHWIC E-Series NCE, page 55

48

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

EHWIC E-Series NCE—Front Panel and Components

Figure 22 Front Panel of the EHWIC E-Series NCE

1 2

1

LED for power

3

Console port

5

Gigabit Ethernet port (GE2)

Figure 23 Internal Components of the EHWIC E-Series NCE

2

1

3 4

2

LED for the system

4

VGA port

5

3

4

EHWIC E-Series NCE

1

Memory DIMM slot

3

Hard disk drive (located under the daughter card)

2

SD0

Note

The SD0 card contains the Cisco Integrated

Management Controller (CIMC) software and must always be present.

4

CMOS battery (located under the daughter card)

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

49

EHWIC E-Series NCE

EHWIC E-Series NCE LEDs

The following table lists the EHWIC E-Series NCE LEDs and describes the LED colors and states.

Table 14 EHWIC E-Series NCE LEDs

LED

Power

SYS

Color

Green

Amber

Green

State

Steady—CIMC and the CPU are both operating normally.

Blinking—The CPU is operating normally, and CIMC is booting up.

Steady—CIMC is operating normally, and the CPU is powered down.

Note

Blinking—CIMC is in the process of booting up, and the CPU is powered down.

Steady—Operation is normal.

GE Port

LEDs

Note

If DRAM is not detected, the SYS LED still displays solid green.

Blinking—System is booting before entering the EFI shell.

Amber Fault is detected on the processor.

Green Left LED shows the condition of the traffic:

Green

Blinking—Traffic is detected.

Off—There is no traffic.

Right LED shows whether the link is established:

Steady—Link is established.

Off—No link is established.

Basic Workflow for Installing the EHWIC E-Series NCE in the EHWIC Slot

Step 1

Step 2

Step 3

Step 4

Step 5

Action

Gather the required tools and equipment.

Reference Topic

“Tools and Equipment Required for Installation” section on page 26

Remove the blank faceplate from the EHWIC slots that you want to use.

“Removing Blank Faceplates from the EHWIC Slots” section on page 51

Remove the slot divider from the

EHWIC slot for EHWIC E-Series

NCE installation.

Install the EHWIC E-Series NCE into the router.

Verify the EHWIC E-Series NCE installation.

“Removing Slot Dividers from EHWIC Slots” section on page 51

“Installing the EHWIC E-Series NCE into the Router” section on page 52

“Verifying EHWIC E-Series NCE Installation” section on page 55

50

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

EHWIC E-Series NCE

Removing Blank Faceplates from the EHWIC Slots

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Using either a number-1 Phillips screwdriver or a small flat-blade screwdriver, unscrew the captive screws and remove the blank faceplate from the chassis slot you plan to use. (See

Figure 23

and

Figure 24 .)

Figure 24 Removing the Blank Interface Faceplate with Double Thumb Screws

DO NOT INSTALL WAN INTERFACE

CARDS WITH POWER APPLIED

1

1

A blank interface faceplate with double thumb screws.

Step 2

Save the blank faceplates for future use.

What to Do Next

Remove the slot dividers from the EHWIC slot. See the

“Removing Slot Dividers from EHWIC Slots” section on page 51

.

Removing Slot Dividers from EHWIC Slots

Slot dividers are removed to permit use of double-wide EHWIC E-Series NCE in the router slots.

Note

The EHWIC slots on both sides of a slot divider must be empty before you remove the slot divider.

Before You Begin

Make sure that you connect the wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

51

EHWIC E-Series NCE

Procedure

Step 1

Step 2

Remove any installed interface cards and blank faceplates from the router slot you plan to use.

Loosen the retention screw on the slot divider. See

Figure 25

.

Figure 25 Cisco ISR G2 EHWIC Slot Divider

DO NO

T REMO

NETWORK OPERA

TION

DO NO

T REMO

NETWORK OPERA

TION

1

Retention screws

1

Step 3

Pull the slot divider straight out of the EHWIC slot.

What to Do Next

Install the EHWIC E-Series NCE into the router. See the

“Installing the EHWIC E-Series NCE into the

Router” section on page 52

.

Installing the EHWIC E-Series NCE into the Router

The EHWIC E-Series NCE can be installed either before or after mounting the router, whichever is convenient.

Warning

Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Statement 1030

Warning

To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some

LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Statement 1021

Warning Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables,

detach the end away from the unit first. Statement 1026

52

Caution

To prevent damage to the server, handle the server by the chassis or frame.

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

EHWIC E-Series NCE

Before You Begin

Verify that you have done the following:

1.

Removed the blank faceplate from the EHWIC slots that you want to use. See the “Removing Blank

Faceplates from the EHWIC Slots” section on page 51

.

2.

3.

4.

Saved the blank faceplates for future use.

Removed the slot divider from the EHWIC slot for EHWIC E-Series NCE installation. See the

“Removing Slot Dividers from EHWIC Slots” section on page 51 .

Connected a wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Step 2

Turn off electrical power to the router. Leave the power cable plugged in to channel ESD voltages to ground.

Remove all network cables, including telephone cables, from the router.

Caution

To prevent damage to the interface card, turn off electrical power and disconnect network cables from the chassis before inserting an interface card into an installed network module or router slot.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

53

EHWIC E-Series NCE

Step 3

Align the EHWIC E-Series NCE with the guides in the chassis walls or slot divider, and slide it gently into the slot. (See

Figure 26 .)

Figure 26 Installing the Double-Wide EHWIC E-Series NCE in a Cisco ISR G2

2

1

DO NO

TION

DO NO

TION

1

Double-wide EHWIC E-Series NCE

2

ISR G2

Caution

Do not touch the EHWIC E-Series NCE board. Handle the EHWIC E-Series NCE by the edges of the faceplate to reduce the risk of damage to the card.

Step 4

Using the faceplate, push the EHWIC E-Series NCE into place until you feel the EHWIC seat securely into the connector on the router backplane. The interface card faceplate should contact the chassis rear panel.

Caution

Do not connect cables to EHWIC E-Series NCE until you have installed it.

Step 5

Using a number-1 Phillips or flat-blade screwdriver, tighten the captive mounting screws on the EHWIC

E-Series NCE faceplate.

54

What to Do Next

1.

Load a compatible Cisco IOS image.

2.

Connect the EHWIC E-Series NCE to the network and then power up the router and the NCE.

3.

Verify that the router recognizes the EHWIC E-Series NCE. See the

“Verifying EHWIC E-Series

NCE Installation” section on page 55 .

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

EHWIC E-Series NCE

Verifying EHWIC E-Series NCE Installation

Before You Begin

1.

Install the EHWIC E-Series NCE into the router.

2.

Load a compatible Cisco IOS image. See the “Cisco ISR G2, E-Series Server, NCE, and Cisco IOS

Software Release Compatibility” section in the Release Notes for Cisco UCS E-Series Servers and

the Cisco UCS E-Series Network Compute Engine, Release 3.x.

3.

Power on the EHWIC E-Series NCE.

Procedure

To verify that the router detects the presence of the newly installed EHWIC E-Series NCE, use the show

inventory command.

Router> show inventory

NAME: “CISCO3945-CHASSIS”, DESCR: “CISCO3945-CHASSIS”

PID: CISCO3945-CHASSIS, VID: V02, SN: FGL1539100Q

NAME: “Cisco Services Performance Engine 150 for Cisco 3900 ISR on Slot 0", DESCR: “Cisco

Services Performance Engine 150 for Cisco 3900 ISR”

PID: C3900-SPE150/K9, VID: V05, SN: FOC15367HAZ

NAME: “Enhanced WAN Interface Card UCS Server on Slot 0 SubSlot 3", DESCR: “Enhanced WAN

Interface Card UCS Server”

PID: UCS-EN120E-M2/K9, VID: V01, SN: FOC17462K2A

NAME: “C3900 AC Power Supply 1", DESCR: “C3900 AC Power Supply 1"

PID: PWR-3900-AC, VID: V03, SN: SNI1511C8SM

Online Insertion and Removal—EHWIC E-Series NCE

Note

OIR is not supported on the EHWIC E-Series NCE.

Installing the Field Programmable Gate Array Image in the EHWIC E-Series NCE

Caution

The Field Programmable Gate Array (FPGA) comes preinstalled when you purchase the

EHWIC E-Series NCE. Use this procedure only if Cisco Systems requires you to install a new FPGA image.

Procedure

Step 1

Step 2

Download the fpga-name.rbf image file from the assigned tftp server onto the Flash drive.

Use the following command to install the FPGA image:

Router # ucse subslot slot/port-adapter fpga-upgrade flash:fpga-name.rbf

Warning

Do not power cycle the router during the FPGA installation process.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

55

NIM E-Series NCE

Step 3

After the installation completes, power cycle the router for the new FPGA image to take effect.

Note

If you accidentally lose power during the upgrade process, the FPGA falls back to the factory-installed image. To ensure proper functionality, you must reinstall the new FPGA image.

NIM E-Series NCE

See the following sections for more information about NIM E-Series NCE:

NIM E-Series NCE—Front Panel and Components, page 56

NIM E-Series NCE LEDs, page 59

Basic Workflow for Installing the NIM E-Series NCE in the NIM Slot, page 59

Online Insertion and Removal—NIM E-Series NCE, page 63

NIM E-Series NCE—Front Panel and Components

The following figure shows the front panel of the NIM E-Series NCE.

Figure 27

9 8

Front Panel of the NIM E-Series NCE

KVM

NIM

IMC

SSD

EN

PWR

USB

SYS

5 6

GE2

7 1 2

3

1

EN LED

3

Power LED

5

LED for the system

4

7

GE Port

9

LED for the CIMC

UCS-

EN140N

-M2/K9

2

Management port

4

USB

6

KVM port used for keyboard, video, and mouse (KVM) connector

Note

Use the KVM connector that is shipped with the NIM E-Series NCE.

See

Figure 28

.

8

LED for the SSD drive

56

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

NIM E-Series NCE

The following figure shows the KVM connector that is shipped with the NIM E-Series NCE.

Figure 28 KVM Connector

1

2

3

1

DB15 connector—video port

3

DB9 connector—serial port

2

USB connector

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

57

NIM E-Series NCE

The following figure shows the internal components of the NIM E-Series NCE.

Figure 29 Internal Components of the NIM E-Series NCE

2

1

4

2

HDD

3

1

CMOS battery (located under the daughter card)

3

Memory DIMM slots (located under the daughter card)

4

SD0

Note

The SD0 card contains the Cisco

Integrated Management Controller

(CIMC) software and must always be present.

58

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

NIM E-Series NCE

NIM E-Series NCE LEDs

The following table lists the NIM E-Series NCE LEDs and describes the LED colors and states.

Table 15 NIM E-Series NCE LEDs

LED

Power

SYS

Color

Green

Amber

Green

State

Steady—CIMC and the CPU are both operating normally.

Blinking—The CPU is operating normally, and CIMC is booting up.

Steady—CIMC is operating normally, and the CPU is powered down.

Note

Blinking—CIMC is in the process of booting up, and the CPU is powered down.

Steady—Operation is normal.

IMC

SSD

GE Port

LEDs

Note

If DRAM is not detected, the SYS LED still displays solid green.

Blinking—System is booting before entering the EFI shell.

Amber Fault is detected on the processor.

Green

Green

Green

Blinks when the CIMC is operating normally.

Blinks when the SSD is operating normally.

Left LED shows the condition of the traffic:

Blinking—Traffic is detected.

Green

Off—There is no traffic.

Right LED shows whether the link is established:

Steady—Link is established.

Off—No link is established.

Basic Workflow for Installing the NIM E-Series NCE in the NIM Slot

Step 1

Step 2

Step 3

Step 4

Action

Gather the required tools and equipment.

Reference Topic

“Tools and Equipment Required for Installation” section on page 26

— Remove the blank faceplates from the NIM slot that you want to use.

Install the NIM E-Series NCE into the router.

Verify the NIM E-Series NCE installation.

“Installing the NIM E-Series NCE into the Router” section on page 60

“Verifying NIM E-Series NCE Installation” section on page 62

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

59

NIM E-Series NCE

Installing the NIM E-Series NCE into the Router

The NIM E-Series NCE can be installed either before or after mounting the router, whichever is convenient.

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Statement 1030

Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some

LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Statement 1021

Warning

Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables,

detach the end away from the unit first. Statement 1026

Caution

To prevent damage to the server, handle the server by the chassis or frame.

Before You Begin

Do the following:

1.

2.

3.

Using either a number-1 Phillips screwdriver or a small flat-blade screwdriver, unscrew the captive screws and remove the blank faceplate from the chassis NIM slot that you want to use.

Save the blank faceplates for future use.

Connect a wrist-strap clip to an unpainted portion of the chassis frame to channel unwanted ESD voltages to ground.

Procedure

Step 1

Step 2

Turn off electrical power to the router. Leave the power cable plugged in to channel ESD voltages to ground.

Remove all network cables, including telephone cables, from the rear panel of the router.

60

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

NIM E-Series NCE

Step 3

Align the NIM E-Series NCE with the guides in the chassis walls or slot divider, and slide it gently into the NIM slot. (See

Figure 30 .)

Figure 30 Installing the NIM E-Series NCE in a Cisco ISR 4000 Series

1

2

2

Cisco ISR 4000 series

1

NIM E-Series NCE

Caution

Do not touch the NIM E-Series NCE board. Handle the NIM E-Series NCE by the edges of the faceplate to reduce the risk of damage to the card.

Step 4

Using the faceplate, push the NIM E-Series NCE into place until you feel the NIM seat securely into the connector on the router backplane. The NIM faceplate should contact the chassis rear panel.

Caution

Do not connect cables to NIM E-Series NCE until you have installed it.

Step 5

Using a number-1 Phillips or flat-blade screwdriver, tighten the captive mounting screws on the NIM faceplate.

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

61

NIM E-Series NCE

What to Do Next

4.

Load a compatible Cisco IOS image. See the “Cisco ISR 4000, E-Series Server, NCE, CIMC and

Cisco IOS Software Release Compatibility” section in the Release Notes for Cisco UCS E-Series

Servers and the Cisco UCS E-Series Network Compute Engine, Release 3.x.

5.

Connect the NIM E-Series NCE to the network and then power up the router and the NIM.

6.

Verify that the router recognizes the NIM E-Series NCE. See the

“Verifying NIM E-Series NCE

Installation” section on page 62 .

Verifying NIM E-Series NCE Installation

Before You Begin

1.

Install the NIM E-Series NCE into the router.

2.

3.

Load a compatible Cisco IOS image. See the “Cisco ISR 4000, E-Series Server, NCE, CIMC and

Cisco IOS Software Release Compatibility” section in the Release Notes for Cisco UCS E-Series

Servers and the Cisco UCS E-Series Network Compute Engine, Release 3.x.

Power on the NIM E-Series NCE.

Procedure

To verify the NIM E-Series NCE installation, use one of the following commands:

To display a high-level overview of the entire physical system, use the show platform command:

Router# show platform

Chassis type: ISR4351/K9

0/1 UCS-EN140N-M2/K9 ok 3w5d

1/0 UCS-E140DP-M1/K9 ok 4w6d

2 ISR4351/K9 ok 5w2d

R0 ISR4351/K9 ok, active 5w2d

F0 ISR4351/K9 ok, active 5w2d

P0 PWR-4450-AC ok 5w2d

P2 ACS-4450-FANASSY ok 5w2d

Slot CPLD Version Firmware Version

--------- ------------------- ---------------------------------------

0 14080523 15.4(3r)S1

1 14080523 15.4(3r)S1

2 14080523 15.4(3r)S1

R0 14080523 15.4(3r)S1

F0 14080523 15.4(3r)S1

To verify that the router recognizes the server, use the show hw-module subslot all oir command:

Router# show hw-module subslot all oir

Module Model Operational Status

------------- -------------------- -----------------------subslot 0/0 ISR4351-3x1GE ok subslot 0/1 UCS-EN140N-M2/K9 ok subslot 1/0 UCS-E140DP-M1/K9 ok

62

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

NIM E-Series NCE

Online Insertion and Removal—NIM E-Series NCE

Online insertion and removal (OIR) provides uninterrupted network operation, maintains routing information, and ensures session preservation on the Cisco ISR 4000 series. You can use online insertion and removal to install or replace hardware without affecting system operations.

Removing the NIM E-Series NCE from a Cisco ISR 4000 Series

Shutting Down the NIM E-Series NCE Installed in a Cisco ISR 4000 Series, page 63

Restarting the NIM E-Series NCE Installed in a Cisco ISR 4000 Series, page 63

Inserting the NIM E-Series NCE in a Cisco ISR 4000 Series, page 64

Shutting Down the NIM E-Series NCE Installed in a Cisco ISR 4000 Series

SUMMARY STEPS

1.

2.

enable

hw-module subslot 0/NIM-slot-number stop

DETAILED STEPS

Command or Action

Step 1 enable

Purpose

Enables privileged EXEC mode.

Enter your password if prompted.

Example:

Router> enable

Step 2 hw-module subslot 0/

NIM

-slot-number

stop

Example:

Router# hw-module subslot 0/1 stop

Shuts down power to the specified NIM E-Series NCE to prepare it for removal. The NIM slot number can be 1, 2, or

3.

Note

Before removing the NIM E-Series NCE, verify that power to the NIM slot is shut down. The power LED should be off.

Restarting the NIM E-Series NCE Installed in a Cisco ISR 4000 Series

If the stop command is issued and the NIM E-Series NCE is not physically removed from the slot, you can restart the NIM E-Series NCE with the start command. From a console terminal, issue the

hw-module subslot 0/NIM-slot-number start command. The console displays the module’s changing state.

Example:

Router# hw-module subslot 0/1 start

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

63

Removing the COA

Inserting the NIM E-Series NCE in a Cisco ISR 4000 Series

A Cisco ISR 4000 series that is up and running can detect when an NIM E-Series NCE is inserted in the

NIM slot. After the router detects the NIM E-Series NCE, the router software enables power to the server.

Removing the COA

In the event that you need to return the E-Series Server, make sure that you retain the original Certificate of Authenticity (COA) label. The COA is the label from Microsoft with the code that enables their windows software. After you return the server, Cisco Systems cannot retrieve the COA label from the returned server.

The COA label is attached to the inside half of a plastic pull out label tray. To remove the COA label, cut away the half of the label that contains the COA label and save it. Return the unit with the other half of the label tray, which contains the units CLEI code, serial number, and other important unit labels, to

Cisco Systems or your licensed reseller.

Figure 31 COA Label Location

1

1

Plastic pull label tray

Note

The COA label from Microsoft is single layer and not foldable.

64

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04

Cisco Integrated Management Controller

Cisco Integrated Management Controller

Cisco Integrated Management Controller (CIMC) is a separate management module built into the motherboard. CIMC is the management service for the E-Series Servers. You can use a web-based GUI or SSH-based CLI to access, configure, administer, and monitor the server. For more information on

CIMC, see the GUI Configuration Guide for Cisco UCS E-Series Server and the Cisco UCS E-Series

Network Compute Engine.

Related Documentation

For more information about Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute

Engine, see the following related documentation:

For links to the following Cisco UCS E-Series Servers and the Cisco UCS Network Compute Engine documents, see the

Documentation Guide for Cisco UCS E-Series Servers

:

Release Notes for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute

Engine

Getting Started Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network

Compute Engine

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series

Network Compute Engine (this document)

Cisco Network Modules, Server Modules, and Interface Cards Regulatory Compliance and

Safety Information

Host Upgrade Utility Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series

Network Compute Engine

GUI Configuration Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network

Compute Engine Integrated Management Controller

CLI Configuration Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network

Compute Engine Integrated Management Controller

CIMC XML API Programmer’s Guide for Cisco UCS E-Series Servers and the Cisco UCS

E-Series Network Compute Engine

Troubleshooting Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network

Compute Engine

Open Source Used in Cisco UCS E-Series Servers

Documentation Guides for Third Party Plug-in Tools

For information about installing and connecting the Cisco 2900 series and Cisco 3900 ISRs, see the

Cisco 3900 Series and Cisco 2900 Series Hardware Installation Guide

.

For information about installing and connecting the Cisco ISR 4000 Series, see the

Hardware

Installation Guide for the Cisco 4400 and Cisco ISR 4300 Series Integrated Services Router

.

For regulatory compliance and safety information, see the

Cisco Network Modules and Interface

Cards Regulatory Compliance and Safety Information

document.

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of

Cisco trademarks, go to this URL: www.cisco.com/go/trademarks . Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)

OL-26447-04

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

65

Related Documentation

Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only.

Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.

© 2015 Cisco Systems, Inc. All rights reserved.

66

Hardware Installation Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

OL-26447-04