Panasonic NR-B472TZ S5, NR-B412TZ S5 refrigerator Service manual
The NR-B472TZ S5 and NR-B412TZ S5 refrigerators offer efficient cooling solutions for your home. These models feature a frost-free system to prevent ice buildup, ensuring convenient maintenance. The micro-computer control allows for precise temperature adjustment and energy-saving operation. You can enjoy the convenience of a quick freezing function to rapidly cool your food.
Advertisement
Advertisement
1.1 Specifications
MODEL
SPECIFICTIONS
Storage Capacity
Gross Capacity
Outside dimensions
Width
Depth
Height
Net weight
Type
Temperature control
Defrosting
Defrost water disposal
Exterior finish
Inner liner
Insulation
Power source
SEALED UNIT
Compressor
(Winding Resistance
measured at 20
℃ )
NR-B472TZ-S5
448 L (PC : 338 L,FC : 110 L)
468 L (PC : 356 L,FC : 112 L)
697 mm
754 mm
1828 mm
72 kg
Frost-free refrigerator
Micro-computer control (FC
:FCC sensor) / Full-automatic direct control (PC:Damper thermo.)
Full-automatic control Start : micro-computer ; Finish : Defrost sensor
Full-automatic (Forcible evaporated into the air)
Polyester coated finish
Vacuum formed ABS resin
Polyurethane foam (cabinet & door)
110 V / 60 Hz , 110 V / 50 Hz , 120 V / 60 Hz , 120 V / 50 Hz
EFI100E13DGH
(U-W)
(U-V)
8.44 Ω
8.44 Ω
(V-W) 8.44 Ω
Fin tube type
Wrapper type (Consealed condenser)
R600a , 60g
215ml
Evaporator
Condenser
Refrigerant charge
Oil charge
ELECTRIC PARTS
Overload protector
FCC Sensor
DEF. Sensor
Fan motor
Fuse
Defrost heater
PC damper thermo.
LED Lamp
Door switch (PC)
MM3-71CCQ
R-20 19.09 KΩ B:3850K
R13 3.4338 KΩ B:3850K
4515JL-09W-B36-GF6
E4A00072C , 250V / 10A / 72
℃ or SF70E,250V / 10A / 73℃
127V/180W/ 89.6 Ω
SD-0306 d.c 12V / 1.5 W
125 V / 5 A , 250 V / 2.5 A
1.2 Specifications
MODEL
SPECIFICTIONS
Storage Capacity
Gross Capacity
Outside dimensions
Width
Depth
Height
Net weight
Type
Temperature control
Defrosting
Defrost water disposal
Exterior finish
Inner liner
Insulation
Power source
SEALED UNIT
Compressor
(Winding Resistance
measured at 20
℃ )
NR-B412TZ-S5
388 L (PC : 278 L,FC : 110 L)
408 L (PC : 296 L,FC : 112 L)
697 mm
754 mm
1646 mm
65 kg
Frost-free refrigerator
Micro-computer control (FC
:FCC sensor) / Full-automatic direct control (PC:Damper thermo.)
Full-automatic control Start : micro-computer ; Finish : Defrost sensor
Full-automatic (Forcible evaporated into the air)
Polyester coated finish
Vacuum formed ABS resin
Polyurethane foam (cabinet & door)
110 V / 60 Hz , 110 V / 50 Hz , 120 V / 60 Hz , 120 V / 50 Hz
EFI100E13DGH
(U-W) 8.44 Ω
(U-V)
(V-W)
8.44 Ω
8.44 Ω
Fin tube type
Wrapper type (Consealed condenser)
R600a , 60g
215ml
Evaporator
Condenser
Refrigerant charge
Oil charge
ELECTRIC PARTS
Overload protector
FCC Sensor
DEF. Sensor
Fan motor
Fuse
Defrost heater
PC damper thermo.
Lamp bulb
Door switch (PC)
MM3-71CCQ
R-20 19.09 KΩ B:3850K
R13 3.4338 KΩ B:3850K
4515JL-09W-B36-GF6
E4A00072C , 250V / 10A / 72
℃ or SF70E,250V / 10A / 73℃
127V/180W/ 89.6 Ω
SD-0306 d.c 12V / 1.5 W
125 V / 5 A , 250 V / 2.5 A
1.3 TEMPERATURE CHARACTERISTIC
TEMPERATURE OF EACH COMPARTMENT,COMPRESSOR RUNNING RATIO
Temperature
FREEZER COMPARTMENT MIN MED MAX
Adjuetment
REFRIGERATOR COMPARTMENT
Freezer compartment (FC) Temp.(degree)
1
-16.0
MED
-18.0
7
-20.0
Refrigerator compartment (PC) Temp.(degree)
Fine Freesh room (FF) Temp.(degree)
Compressor running ratio (%)
5.0
3.5
63.0%
4.0
1.0
65.0%
0.0
-1.0
68.0%
(CONDITION)
Atmosphere Temperature
:32 degree
NO LOAD (NO FOODS), NO DOOR OPEN AND CLOSE
These indicating temperature is stable condition. (Approximately)
2.Introduction
FUNCTION OF ELECTRONIC CONTROL
2.1 FREEZER TEMPERATURE CONTROL
It actuates the compressor, FC fan motor ,and cooling system switch according to temperature variation in the freezer compartment. And atmosphere temperature by processing the input from, FC temperature sensor and adjustment of temperature control.
2.2 COMPRESSOR ROTATION SPEED CONTROL
According to changing inside temperature,the motor runs in the difference speed. In normal, the motor run in the low speed. (Energy saving & lower noise.)
When powerful cooling is required, motor run in rapid speed.
CONDITION
When to plug in
Quick freezing
Normal operation
NR-B472TZ ROTATION SPEED(rps)
42
42
、71
32
、 36、42、52、 58、 71
2.3 QUICK FREEZING FUNCTION
Press "QUICK FREEZING"button , and then quick function starts and LED sign comes on.
It actuates the compressor continuously for certain period regardless of compartment temperature, by processing the input from AT temperature sensor. (AT temperature : Atmosphere temperature)
ATC under than 18
℃
More than 19
℃
NR-B472TZ continuous run
60 minutes/42rps
150 minutes/71rps
※
When the blue
light is blinking after pressing the "QUICK FREEZING" button, the function of quick freezing
is waiting .The situation of refrigerator is processing as below:
a.The refrigerator is defrosting .
b.The compressor is stopped,because temperature of the freezing compartment reachs setting of temperature.
When the above situation is solved , quick- freeze will be started automatically,then the "QUICK FREEZING"
light bright is on.
2.4 FC DEFROSTING CONTROL
Cumulating the compressor running time of certain period or time after defrosting according to AT temperature,
FC defrosting cycle starts. (AT temperature : Atmosphere temperature)
Termination is detected by defrost sensor ,but maximum defrosting time is 60 minutes (Defrosting forcibly stops).
Accumulating time for defrosting
Compressor protection(IPD) initially starts
Power Interruption
15 hours
4 hours
Continue cycle
ATC After
Accumulation of compressor run time
under than 22℃
More than 33℃
13 hours
―
―
8 hours
2.5 WAITING CONTROL FOR COMPRESSOR RE-STARTING
To re-start the compressor smoothly after compressor stops and after defrosting, it does not actuate the compressor for certain period.
Waiting time for compressor starting
10 minutes After compressor stops
3 minutes After defrosting
Caution
At once unplug, wait for 10 minutes, then plug in.
2.6 FAN MOTOR CONTROL IN FREEZER COMPARTMENT
The fan motor (near FC evaporator )is controlled under below condition.
compartment is closed.Rotation speed changes on 3 degree according to atmosphere temperature and refrigerator compartment.
2.7 PROTECTION OF INVERTER CIRCUIT
When supply voltage drops, IPM protection operates, and compressor protection operates continuously, compressor stops at the moment and indicates code"H41".
CODE
Operation PCB Display
"MAX"LED: light off
H41 "MED"LED: light on
"MIN"LED: light on
"QUICK FREEZING" LED: light off
2.8 DOOR ALARM
When the door of refrigerator compartment is opened after 5 minute ,"QUICK FREEZING"light is red.
"QUICK FREEZING"light is off,when the door of refrigerator compartment is closed.
DOOR OPENING after 1 minute after 3 minutes after 5 minutes
Buzzer sounds
Pee,Pee
Pee,Pee,Pee,Pee
Pee,Pee,Pee,…….
2.9 SELF DIAGNOSIS FUNCTION
If the unit have any problem ,the sign is appeared on LED.
(When "QUICK FREEZING" LED indicate red bright. Press "QUICK
FREEZING" + "FREEZER CONTROL" both bottons 9~13 sec plus than going into SELF DIAGNOSIS FUNCTION.)
(Example:Code"H07")
CODE
H07
Operation PCB Display
"MAX"LED: light off
"MED"LED: light on
"MIN"LED: light off
"QUICK FREEZING" LED: light off
2.10 AUTO ROOM LED LIGHTS OFF
If PC door opens for 1 hour, room
led
lights automatically comes off.
Once closing PC door, this function is reset.
3. Operation Instructions
SELF DIAGNOSIS FUNCTION
*When "QUICK FREEZING" LED indicate red bright.
Press "QUICK FREEZING" + "FREEZER CONTROL" both bottons 9~13 sec plus than going into SELF DIAGNOSIS FUNCTION .
No CODE Operation PCB Display Content
1 U10
"MAX"LED: light off
"MED"LED: light off
"MIN"LED: light off
"QUICK FREEZING" LED
: light on
Door opened alarm.
Symptom
Refrigerator have not cooling
Confirm point
1.The door of refrigerator
compartment is opened.
2.Door switch is breakdown.
3.Control PCB is breakdown.
Solve
1.Close the refrigerator compartment
door
2.Replace door switch
3.Replace Control PCB
"MAX"LED: light off
"MED"LED: light off
"MIN"LED: light on
Freezer compartment of sensor was open circuit.
Compressor is stopped.
Refrigerator have not cooling at all.
1.Check freezer compartment of
1.Replace freezer compartment of
sensor.
sensor.
2.Check Control PCB of 2.Replace Control PCB.
3.Replace Control PCB. "QUICK FREEZING" LED
Freezer compartment
Compressor is running connector.
2 H01
: light off
3 of sensor was short all the time.
3.Control PCB is breakdown.
circuit.
Refrigerator is over cooling
H05
"MAX"LED: light off
"MED"LED: light off
"MIN"LED: light on at all.
Freezer compartment
Refrigerator have not of sensor put error of cooling at all,or over position
Defrost of sensor was open circuit.
Defrost of sensor
"QUICK FREEZING" LED was short circuit.
cooling at all.
Thermal fuse was cut off in freezer compartment
1.Check defrost of sensor.
2.Check Control PCB of
The refrigerator have not connector.
defrosting .
3.Control PCB is breakdown.
: light on Evaporator have over frost
Defrost of sensor put error of position Refrigerator have not cooling at all.
"MAX"LED: light off
"MED"LED: light on
ATC of sensor was open circuit*.
Refrigerator is over cooling
1.Check ATC of sensor. at all.
2.Check Control PCB of
1.Replace defrost of sensor.
2.Replace Control PCB.
3.Replace Control PCB.
1.Replace defrost of sensor.
2.Replace Control PCB.
3.Replace Control PCB.
4
"MIN"LED: light off
H07
"QUICK FREEZING" LED
: light off
ATC of sensor was short circuit*.
Refrigerator have not cooling at all.
connector.
3.Control PCB is breakdown.
5 H31
"MAX"LED: light on
"MED"LED: light on
"MIN"LED: light on
"QUICK FREEZING" LED
: light on
Freezer compartment
Refrigerator have not defrost abnormal defrosting.
1.Check defroster of heater.
2.Check Control PCB of
connector.
3.Control PCB is breakdown.
4.Thermal fuse was cut off
in freezer compartment.
1.Replace defroster of heater
2.Replace Control PCB.
3.Replace Control PCB.
*ATC sensor is to measure atmosphere temperature . ATC sensor put on operation board.
No CODE Operation PCB Display Content
"MAX"LED: light off
"MED"LED: light on
"MIN"LED: light on
8 H40 "QUICK FREEZING" LED
: light off
Protection of IPM for compressor lock
Symptom Confirm point Solve
1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
indicate red bright.
9 H50
"MAX"LED: light on
"MED"LED: light on
"MIN"LED: light on
"QUICK FREEZING" LED
: light off
Control PCB of communication is abnormal.
1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
indicate red bright.
10 H35
"MAX"LED: light on
"MED"LED: light off
Control PCB is abnormal.
"MIN"LED: light on (DFC of sensor less
"QUICK FREEZING" LED then -41℃)
: light off
1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
indicate red bright.
2.Check DFC of sensor.
2.Replace DFC of sensor
2. Refrigerator have not
cooling.
11 H36
"MAX"LED: light on
"MED"LED: light off
Control PCB is abnormal.
"MIN"LED: light on (DFC of sensor more
"QUICK FREEZING" LED then 41℃)
: light on
1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
indicate red bright.
2.Check DFC of sensor.
2.Replace DFC of sensor
2. Refrigerator have over
cooling.
"MAX"LED: light on
"MED"LED: light on
Ambient brightness sensor was open circuit.
"MIN"LED: light off
12 H64
"QUICK FREEZING" LED
Ambient brightness
: light on sensor was short circuit.
1.Check Ambient brightness
2.Check Control PCB of
1.Replace Control PCB.
connector.
4.Troubleshooting Guide
4.1 Symptom 1. Refrigerator have not cooling at all.
Compressor does not run
‧Press "QUICK FREEZING" botton 1~2 sec ,then release
Check compressor is running or not.
NO
Check compressor side of connector dropped or not.
NO
YES
YES
Check control PCB of compressor of connector dropped or not.
NO
‧
Press "QUICK FREEZING" + "FREEZER CONTROL" both bottons 9~13 sec
*Reconnect compressor side of connector.
*Reconnect control PCB of compressor of connector.
"MAX"LED: light on
"MED"LED: light on
"MIN"LED: light on
"QUICK FREEZING"LED: light off
CODE(H50)
NO
*Replace control PCB.
(Circuit problem happens between IC1
and IC 201).
"MAX"LED: light off
"MED"LED: light on
"MIN"LED: light on
"QUICK FREEZING"LED: light off
CODE(H40)
YES
*Replace Control PCB .
(Faulty at compressor control circuit) or *Replace compressor.
(Compressor Lock)
4.2 Symptom 2. poor cooling.
Does "QUICK FREEZING" LED indicate red bright?
NO
Is door open?
YES
‧
Press "QUICK FREEZING" + "FREEZER CONTROL" both bottons 9~13 sec
NO
"MAX"LED: light off
"MED"LED: light off
"MIN"LED: light on
"QUICK FREEZING"LED: light off
CODE(H01)
NO
YES
"MAX"LED: light off
"MED"LED: light off
"MIN"LED: light on
"QUICK FREEZING"LED: light on
CODE(H05)
YES
YES
*Close door
*Replace door switch.
(Faulty at door switch, freezer of compartment fan motor stop running)
*Replace freezer of compartment sensor
(sensor open circuit).
Is temperature fuse breakdown?
NO
*Replace Defrost heater
(heater open circuit).
or *Replace Control PCB.
(Faulty of relay on control
PCB)
NO
YES
*Replace Defrost sensor
(sensor open circuit).
and *Replace temperature fuse(fuse open circuit).
"MAX"LED: light on
"MED"LED: light on
"MIN"LED: light on
"QUICK FREEZING"LED: light on
CODE(H31)
YES
Is temperature fuse breakdown?
NO
*Replace Defrost heater
(heater open circuit).
or *Replace Control PCB.
(Faulty of relay on control
PCB)
NO
YES
*Replace Defrost sensor
(sensor open circuit).
and *Replace temperature fuse(fuse open circuit).
NEXT PAGE
4.3 Symptom 2. FC/PC are poor cooling.
YES
Does evaporator get too much frost?
NO
NO
Is resistance of defrost sensor
6.33-6.437kΩ(at 0 ℃)
YES
*Re-put Defrost of sensor position.
( Defrost of sensor drop)
*Replace defrost sensor
(sensor of resistance is smaller)
*Replace control PCB.
(Faulty of defrost sensor of circuit detected on control PCB)
5. Disassembly and Assmbly Instructions
5.1 ICE TRAY RAIL
‧Take out the CRYSTAL SHELF FC
‧Take out the ICE BOX
‧Take out the ICE TRAY AS.
‧Remove the screw ( 2 pcs)
‧Remove the ICE TRAY RAIL
ICE TRAY RAIL
ICE TRAY AS
ICE BOX
ICE TRAY RAIL
5.2 COVER COIL
‧Remove the COVER
like right figure show
‧Remove the screw ( 2 pcs)
‧Remove the COVER CONNECTOR FC
‧Remove the screw ( 1 pcs)
‧Disconnect all the connector of harness
‧Remove the COVER COIL
COVER COIL
5.3 DC FAN MOTOR
‧Remove the COVER COIL
‧Remove the DC FAN MOTOR
To replace the DC fan motor
‧Insert the DC fan motor case into the
COVER COIL BACK
‧Connect the terminal.
CONNECTOR BAG
COVER
Lead wire
COVER CONNECTOR FC
HOOK
HOOK
5.4 FCC SENSOR
‧Remove the screw ( 1 pcs ) and remove the Al tape
‧Disassembly the hook around side
‧Disassembly the COVER COIL FRONT and COVER COIL BACK
‧Remove the FCC SENSOR
COVER COIL BACK
To replace the FCC SENSOR
‧FCC SENSOR should be hooked in plate.
COVER COIL FRONT
HOOK
‧Remove the Al tape
5.5 DEFROST HEATER
CONNECTOR
‧Remove the cover coil as.
‧Remove the lead wire .
‧Disconnect both side connector of heater lead wire .
‧Lifting the evaporator at right gradually, pull it toward you.
‧Remove the DEFROST HEATER.
Lead wire
NOTE :
Special care should be taken not to twist and break the pipe.
Lead wire
CONNECTOR
DFC SENSOR
FIN EVAPARATOR
HooK
TEMP FUSE
DEFROST HEATER
HooK
5.6 TEMP FUSE & DFC SENSOR
‧Remove the Lead wire
‧Disconnect the connector of TEMP FUSE.
‧Remove the TEMP FUSE.
DFC SENSOR
Lead wire
TEMP FUSE
To replace the DFC SENSOR
‧DFC SENSOR should be hooked in plate.
5.7 LED COVER & LED LAMP PCB
BUTTON CONTROL
PANEL.
DIAL THERMO PC
Control panel
LED Lamp cover
Screw
5.8 CONTROL PANEL PC
‧Remove the LED pcb connector
‧Remove the screw(4pcs).
‧Use a slotted screwdriver to unhook the LED lamp cover
gently knock
Don't dig into the led's lamp cover
‧ LED lamp cober Assembly
‧Take the control panel AS.
5.9 DAMPER THERMOSTAT
‧Remove Control panel and pull out the ‧Remove the thermostat dial.
PULL
PULL
‧Tear off the tapes on insulation.
Open the insulation from the front side pull the upper portion.
‧Remove the damper thermostat from insulation.
Ins. Control panel back
‧Disconnect the terminal.
‧Disconnect the ins. control panel AS. & control panel.
Control panel
Damper thermo.
Ins. Control panel front
Ins.control panel AS.
To replace damper thermo.
‧Sealing dial should be put in place.
‧Seal the gap between the front insulation and the back insulation
by putting tape.
‧Hook the sensor bulb in place.
5.10 STARTING RELAY & OVERLOAD PROTECTOR
‧
Pull the potector cover leftwards to remove.
‧
Pull the starting relay leftwards to remove.
Pulling
Starting relay
Protector cover
‧Pull out the overload protector.
Protector cover
Overload protector
Starting relay
To replace starting relay
‧Insert the starting relay into comp. pin.
‧Install the overload protector into protector cover.
‧Pushing the protector cover into comp.
Pushing
REFRIGERANT FLOW DIAGRAM
‧Refrigerant flows in the refrigerating units as shown in the figure.
‧Number in the figure of " PIPE LAYOUT " corresponds to number in the refrigerant flow diagram.
Suction pipe(Evaporator)
Pipe pan water eva.
Mullion Side
Mullion Side
Mullion Bottom
Mullion Front
Mullion Front
COMP
Dryer
5.11 Refrigeration system diagram
MULLION DRYER FRONT
B412TZ:¢4 x t0.38—1/2H L=6038
B472TZ:¢4 x t0.38—1/2H L=6504
MULLION DRYER SIDE
B412TZ:¢4 x t0.38—1/2H L=11561
B472TZ:¢4 x t0.38—1/2H L=11071
Screw
Evaporator
PIPE PAN WATER AS.
¢4 x t0.4 L=1510
SUCTION JOINT PIPE
¢6.35 x t0.5 L=435
MULLION DRYER BOTTOM
¢4 x t0.4 L=1939
COMP
GAS CHARE PIPE
¢6.35 x t0.6 L=120
PAN WATER EVA JOINT PIPE
¢4.76 x t0.4 L=433
Dryer
CAPILLARY TUBE
DRYER JOINT PIPE
¢4 x t0.38 x 1/2H L=170
GAS CHAR DRYER PIPE
¢4 x t0.6 L=100
6. Installation Dimensions
100mm
300mm
697mm
100mm
754mm
40mm
(500mm)
7. Wiring Connection Diagram
8. Schematic Diagram
9. Location and Replacement Parts List
9.1.1 Location of Parts
NR-B412TZ
9.1.2 Location of Parts
NR-B472TZ
9.1.3 Replacement Parts List
Ref.No
Service Parts No.
Parts Name & Description
100
CNRBC-33918S
CNRBC-33921S
SHELL N LINER AS.(FOAM)
SHELL N LINER AS.(FOAM)
101 CNRAD-33380DH COVER HINGE TOP
102 CNR38-193801T
103 CNRAE-11710T
104 CNRBH-14171B
105 CNRAE-11663T
106 CNR38-193801T
FLANGE N HEXAGON 5 TS 14
HINGE TOP R
CRYSTAL SHELF FC AS.
HINGE CENTER
FLANGE N HEXAGON 5 TS 14
107 CNRAG-16606T
108 CNRAH-13282W
109 CNRXTT4+12AV
110 CNRAH-28654B
111 CNRAH-28653B
DOOR SW.
MEAT TRAY STOPPER
TRUSS 4 TS 12AV
MEAT TRAY
MEAT TRAY DOOR
112 CNRAH-28697T
113 CNRAH-28655B
114 CNRBC-33895Z
115 CNRBC-16959Z
116 CNRAC-18337T
117 CNRAC-24022T
118 CNR38-193801T
119 CNRAD-34582T
120 CNRBD-35229S
121 CNRAD-33980T
122 CNRBD-35233B
123 CNRXTT4+12AV
124 CNRAH-28644B
125 CNRAD-13785B
126 CNRAH-28645B
127 CNRAH-28646B
GLASS SHELF PC
CRISPER
CASTER AS R.
CASTER AS. L
ADJUSTER BOLT R
ADJUSTER BOLT
FLANGE N HEXAGON 5 TS 14
FC DOOR GASKET
DOOR AS. FC (FOAM)
EMBLEM MARK PLATE
OPERATION PANEL AS
TRUSS 4 TS 12AV
SUP. SHELF FC
TRAY EGG 10
EGG SHELF
FREE RACK
128 CNRAD-34628T
129 CNRAH-28647B
CNRAD-34602T
130
CNRAD-34598T
131
CNRBD-35231S
CNRBD-35227S
132 CNRAD-34681B
133 CNRAK-15304T
134 CNRAK-15222T
135 CNRAK-15223T
136
CNRAK-15307S
CNRAK-15306S
137 CNRAK-153320
SLIDE STOPPER PC
BOTTLE SHELF PC
PC DOOR GASKET
PC DOOR GASKET
DOOR AS. PC(FOAM)
DOOR AS. PC(FOAM)
OPERATION SHEET
OPERATION MANUAL
CORNER ROCK TOP R
CORNER ROCK TOP L
PACKING CASE
PACKING CASE
POLYLON BOTTOM BASE
B412TZ-S5 B472TZ-S5 PCS/SET
○
○
○
○
○
○
○
○
○
○
─
○
○
○
○
○
○
○
○
○
○
○
─
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
─
○
○
─
○
○
○
○
─
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
─
○
○
○
○
○
○
○
─
○
─
1
1
1
1
1
1
1
2
1
2
2
2
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
4
1
1
1
1
3
1
2
2
1
1
3
1
2
1
1
1
NOTE
B412TZ
B472TZ
B412TZ
B472TZ
9.2.1 Location of Parts
9.2.2 Replacement Parts List
Ref.No
Service Parts No.
Parts Name & Description
201 CNRAH-13309W
202 CNRXTT4+12AV
203 CNRBH-10241W
204 CNRAH-13308B
205 CNRAC-22768T
ICE TRAY RAIL
TRUSS 4 TS 12AV
ICE TRAY AS.
ICE BOX
EVA HOLDER R.
206 CNRAC-22769T EVA HOLDER L.
207 CNRXTT4+12AFJ TRUSS 4 TS 12
208 CNRAF-17324T
209 CNRBG-19005T
FIN EVAPARATOR
TEMP. FUSE AS.
210 CNRAG-17160T
211 CNRAG-17272T
COVER RADIANT HEATER
DEFROST HEATER
212 CNRXTN4+10AFJ TRUSS 4 TS 10
213 CNRAC-22736T COVER COIL BACK
214 CNRAG-17174T
215 CNRAJ-14076T
216 CNRBG-19158T
217 CNRAC-22737T
FC FAN MOTOR 6P
FAN MOTOR PU FOAM
FCC SENSOR AS
COVER COIL FRONT
218 CNRXTT4+16A
219 CNRAC-22754T
TRUSS 4 TS 16
COVER CONNECTOR FC
220 CNRXTT4+12AFJ TRUSS 4 TS 12
221 CNRAJ-14088T SEAL PU FOAM
INS. CONTROL PANEL B CNRAC-22751T
222
CNRAC-22739T
223 CNRAG-17190T
INS. CONTROL PANEL B
BAFFLE THER
224 CNRAC-22738T
225 CNRAH-28763T
INS. CONTROL PANEL F
DIAL THERMO PC
226 CNRAH-24552T
CNRAH-28663T
227
CNRAH-28640T
AG BIO FILTER
CONTROL PANEL
CONTROL PANEL
228 CNRXTT4+12AFJ TRUSS 4 TS 12
229 CNRAH-13267W
CNRBG-18819T
230
CNRBG-15194T
BUTTON CONTROL PANEL
LED LAMP PCB AS.
CNRAH-28665T
LED LAMP PCB AS.
LED LAMP COVER
231
CNRAH-28642T LED LAMP COVER
232 CNRXSB4D8BNS BIND 4 SCREW 8
233 CNRBG-19022T
234 CNRBG-18048T
MICON PCB AS
NOISE FILTER AS.
235 CNRBG-19184T
236 CNRXTT4+12AV
AC CORD AS.
TRUSS 4 TS 12AV
237 CNRBE-10924T COVER PLATE PCB BASE AS.
238 CNRC4585-480AJ SPECIAL SCREW
240 CNRAK-15175T
241 CNRAF-14103T
242 CNRBF-13811T
243 CNRAJ-10222T
244 CNR39-03011T
CAUTION LABEL
2 WAY DRYER 5g
PAN WATER EVA AS.
FLANGE N TRUSS 4 TS 13
U-RING 7
245 CNR06-59529R
246 CNRGD-12208T
247 CNRBF-11363T
CNR91-23682T
248
CNR91-23682A
249 CNR39-941120T
250 CNRBF-15607T
251 CNR08-21784A
252 CNRAG-16608T
OVERLOAD PROTECTOR
PROTECTOR COVER
PIPE PAN WATER EVA.AS.
COMP
COMP
RUBBER GROMMET
COMP. BASE N ROLLER AS.
FLANGE N HEXAGON 5 TS 18
DFC SENSOR
B472TZ-S5
○
○
○
─
○
○
○
○
─
○
─
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
─
○
○
○
○
○
○
○
○
B412TZ-S5
─
○
○
○
─
○
○
○
○
○
○
─
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
─
○
○
○
○
○
○
○
1
4
1
4
1
PCS/SET
1
4
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
2
1
1
2
1
2
1
1
1
1
1
1
1
1
2
1
1
2
1
NOTE
(exclude oil)
(include oil)
Advertisement
Key features
- Frost-free operation
- Micro-computer control
- Quick freezing function
- Energy saving operation
- Defrost sensor
- Fan motor
- Defrost heater