User Manual for Midea Blanc Air Conditioners

Add to my manuals
8 Pages

advertisement

User Manual for Midea Blanc Air Conditioners | Manualzz

USER MANUAL

MIDEA BLANC

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

CR170-RG70A

16117000000634 Thank you very much for purchasing our air conditioner.

Please read this owner's manual carefully before using your air conditioner.

CONTENTS

Remote controller Specifications...................................................

Operation of buttons ............ .........................................................

1

2

Indicators on LCD ..........................................................................

How to use the buttons .................................................................

AUTO/COOL operation....................................................................

6

7

7

DRY/FAN operation.........................................................................

HEAT operation ..............................................................................

8

9

Setting the Timer function .............................................................

9

Handling the remote controller ......................................................

13

Remote Controller Specifications

Model

Rated Voltage

Signal Receiving Range

Environment

RG70A/BGEF, RG70E/BGEF

3.0V(Dry batteries R03/LR03 2)

8m

Operation of buttons

Temp

4

5

6

7

1

3

Mode

Sleep

OK

Timer Options

Super

Fan

Fav.

RG70A/BGEF

2

8

9

10

11

12

13

2

1 ON/OFF Button( )

This button turns the air conditioner ON and OFF.

Temp Up Button( )

Press this button to increase the set temperature or Timer setting hours.

Temp Down Button( )

Push this button to decrease the set temperature or Timer setting hours.

NOTE

When the air conditioner operates under heating mode with the set temperature of

O

17 C, pressing button continously for

3

The indoor unit display shows FP .

Mode Button

Press this button to modify the air conditioner mode in a sequence of following:

AUTO COOL DRY HEAT FAN

NOTE Please do not select HEAT mode if the machine you purchased is cooling only type.

Heat mode is not supported by the cooling only appliance.

4 Sleep button(applicable to RG70A/BGEF)

Used to active/cancel Sleep mode. It can maintain the most comfortable temperature and save energy. This function is available on COOL, HEAT or AUTO mode only .

, , ,,

, , ,,

USER S MANUAL.

ECO Button(applicable to RG70E/BGEF)

Used to enter the energy efficient mode.

Under cooling mode, press this button, the remote controller will adjust the temperature

O automatically to 24 C, fan speed of Auto to save energy(but only if the set temperature

O button, the fan speed will change to Auto, the set temperature will remain unchanged.

Operation of buttons

Temp

6

7

5

4

1

3

Mode

ECO

OK

Timer Options

Super

Fan

Gear

RG70E/BGEF

NOTE:

Pressing the SLEEP button, or modifying the mode or adjusting the set temperature to

Under ECO operation, the set temperature

O should be 24 C or more. it may result in insufficient cooling. If you feel uncomfortable,

just press the ECO button again to stop it.

2

8

9

10

11

12

13

5

6

Timer Button

Press this button to initiate the auto-on/ auto-off time sequence.

Super Button

Press this button under cooling operation,

O the set temperature will change to 17 C, the fan speed shift to high and bring faster cooling operation.

Press this button under heating operation,

O the set temperature will change to 30 C, the fan speed shift to high and bring faster heating operation.

NOTE:

This function is not available under AUTO,

DRY,FAN,Self Clean or Comfort mode.

Press MODE,FAN,SLEEP or ECO button will cancel Super function.

7 Do Not Disturb Button( )

Press this button to turn off the indoor screen display, and also turn off the Air conditioner buzzer, the fan speed shifts to low, which create a comfortable and quiet environment.

Press it again to cancel this function.

Under Do Not Disturb mode, the display will illuminate for 10 seconds while adjusting the mode, set temperature or fan speed, etc.

8 Fan Button

Used to select the fan speed in four steps:

AUTO LOW MED HIGH

NOTE

You can not switch the fan speed in AUTO or DRY mode.

Hold down this button for at least 2 seconds to activate/cancel Silent mode. Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity.

Press Fan, MODE, Sleep, ON/OFF ,ECO or

Gear button will cancel the Silent function.

Operation of buttons

Temp

4

5

6

7

1

3

Mode

Sleep

OK

Timer Options

Super

Fan

Fav.

RG70A/BGEF

2

8

9

10

11

12

13

Used to stop or start vertical louver movement and set the desired left/right air flow direction.

The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically.

10 OK Button

Used to confirm the optional fucntions.

11 Swing Button

Used to stop or start horizontal louver movement or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically.

12 Options Button

Press this button to select the air conditioner function in a sequence of following:

Fresh Follow me Comfort Self clean

Press the Options button to select the desired function, the selected symbol will flash on the display area, then press the OK button to confirm.

FRESH function( )

When the FRESH function is initiated, the

Ionizer/Plasma Dust Collector(depending on models) is energized and will help to remove pollen and impurities from the air.

FOLLOW ME function( )

When the Follow Me function is activated, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the FOLLOW

ME button again.

Comfort function( )

When the Comfort function is activated, automatically. It is not available under fan mode.

Temp

6

7

4

5

1

3

Mode Fan

ECO

OK

Timer Options

Super Gear

RG70E/BGEF

2

8

9

10

11

12

13

13

SELF CLEAN function( )

Under SELF CLEAN mode, the air conditioner will automatically clean and dry the Evaporator and keep it as fresh for the next operation. It is not available under heating or fan mode.

( Indicate optional functions)

Fav.Button(applicable to RG70A/BGEF)

Used to restore the current settings or resume previous settings.

On the first time connecting to the power, if push the Fav. button, the unit will operate on

O

AUTO mode, 26 C, and fan speed is Auto.

Push this button when remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature(if activated).

If pushing more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature(if activated ).

Gear.Button(applicable to RG70E/BGEF)

Press this button to enter the energy efficient mode in a sequence of following:

50% (electrical energy consumption,DR mode)

75% (electrical energy consumption,DR mode)

Previous setting mode

Turn off the unit or activate ECO, sleep, FP,

Super, Silent or Self clean function will cancel the electrical energy consumption control function.

NOTE:

, , ,,

, ,

, ,

,,

,,

Indicators on LCD

Information are displayed when the remote controller is powered up.

Mode display

AUTO COOL DRY HEAT FAN

Displayed when data transmitted.

Displayed when remote controller is ON.

Displayed in ECO mode operation

Battery display(low battery detection)

Displayed when TIMER ON time is set.

Displayed when TIMER OFF time is set.

Not available for this unit.

Displayed when Silent feature is activated

Show set temperature or room temperature, or time under TIMER setting.

Indicated that the air conditioner is operating in Follow me mode

Displayed when select Fresh feature

Displayed when select Self clean feature

Displayed when select Comfort feature

Displayed in Sleep Mode operation.

Displayed in Super Mode operation.

Fan speed indication

Low speed

Medium speed

High speed

AUTO

Auto fan speed

Note:

All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation only the relative functional signs are shown on the display window.

Buttons design is based on typical model and might be slightly different from the

actual one you purchased the actual shape shall prevail.

All the functions described are accomplished by the unit. If the unit has no this

feature, there is no corresponding operation happened when press the relative

button on the remote controller.

When there are wide differences between Remote controller Illustration and

USER'S MANUAL on function description, the description of USER'S MANUAL

shall prevail.

2

1

How to use the buttons

Temp

Mode

ECO

OK

Timer Options

Super

Fan

Gear

3

AUTO operation

SETTING TEMPERATURE

The operating temperature range for units is

O

17-30 C. You can increase or decrease the

O set tmeperature in 1 C increments.

In AUTO mode, the unit will automatically select the COOL, FAN, HEAT or DRY mode based on the set temperature.

1. Press the MODE button to select Auto mode.

2. Set your desired temperature using the

Temp or Temp button.

3. Press the ON/OFFbutton to start the unit.

,

NOTE: FAN SPEED can t be set in Auto mode.

How to use the buttons

2

1

DRY

Temp

Mode Fan

Sleep

OK

Timer Options

Super Fav.

3

DRY operation(dehumidifying)

1. Press the MODE button to select DRY

mode.

2. Set your desired temperature using the

Temp or Temp button.

3. Press the ON/OFFbutton to start the unit.

,

NOTE: FAN SPEED can t be changed in

DRY mode.

COOL operation

1. Press the MODE button to select

COOL mode.

2. Set your desired temperature using

the Temp or Temp button.

3. Press the FAN button to select the

fan speed: AUTO, LOW, MED,or

HIGH.

4. Press the ON/OFF button to start the

unit.

2

1

COOL

Temp

Mode

ECO

OK

Timer Options

Super

Fan

Gear

4

3

FAN operation

1. Press the MODE button to select FAN

mode.

2. Press FAN button to select the fan

speed: AUTO, LOW, MED or HIGH.

3. Press the ON/OFFbutton to start the

unit.

,

, mode. As a result, your remote control s

LCD screen will not display temperature.

1

FAN

Temp

Mode Fan

ECO

OK

Timer Options

Super Gear

3

2

How to use the buttons

2

1

HEAT

Temp

Mode Fan

ECO

OK

Timer Options

Super Gear

4

3

HEAT operation

1. Press the MODE button to select

HEAT mode.

2. Set your desired temperature using

the Temp or Temp button.

3. Press the FAN button to select the

fan speed: AUTO, LOW, MED,or HIGH.

4. Press the ON/OFF button to start the

unit.

performance of your unit s HEAT function may be affected. In such instances, we recommend using this air conditioner in conjunction with other heating appliance.

Setting the TIMER function

Your air conditioning unit has two timer-related functions:

TIMER ON- sets the amount of timer after

which the unit will automatically turn on.

TIMER OFF- sets the amount of time after

which the unit will automatically turn off.

TIMER ON function

The TIMER ON function allows you to set a period of time after which the unit will automatically turn on, such as when you come home from work.

1. Press the Timer button, the Timer on

indicator " " displays and flashes. By

defalt, the last time period that you set

and an "h" (indictiong hours)will appear

on the display.

Note: This number indicates the

amount of time after the current time

that you want the unit to turn on.

For example, if you set TIMER ON for

2 hours, " 2.0h " will appear on the

screen, and the unit will turn on after

2 hours.

2. Press the Temp or button to set

the time when you want the unit to turn

on.

3. Wait 2 seconds, then the TIMER ON

function will be activated. The digital

display on your remote control will then

return to the temperature display.

1 2 x5

Temp

or

3

1sec

4

2sec

TIMER ON function

The TIMER OFF function allows you to set a period of time after which the unit will automatically turn off, such as when you wake up.

1 2 x10

Temp

or

3

1sec

4

2sec

ON/OFF

SLEEP

MODE

FAN

TEMP

SHORT

CUT

TIMER ON

TIMER OF

F

Example: Setting unit to turn on after 5 hours.

NOTE: When setting the TIMER ON or

TIMER OFF functions, up to 10 hours, the time will increase in 30 minute increments with each press. After 10 hours and up to 24, it will increase in 1 hour increments. The timer will revert to zero after 24 hours.

You can turn off either function by setting its timer to " 0.0h " .

ON/OFF

SLE

MODE

FAN

EP

TEMP

SHORT

CUT

TIMER O

N

TIMER O

F F

Example: Setting unit to turn on after 2.5 hours.

Temp

Continue to press

Temp or button untill desired time is reached.

Mode Fan

Setting both TIMER ON and TIMER OFF at the same time

Keep in mind that the time periods you set for both functions refer to hours after the current time. For example, say that the current time is 1:00 PM, and you want the unit to turn on automatically at 7:00 PM. You want it to operate for 2 hours, then automatically turn off at 9:00 PM.

Do the following:

1 2

X12

3 4 sec

Temp

or

5

ON/OFF

MODE

TEMP

SHORT

CUT

TIMER O

N

8

6

X16

Temp

or

7 sec

ON/OFF

MODE

TEMP

SHORT

CUT

TIMER O

N

Timer starts

Example: Setting the unit to turn on after 6 hours, operate for 2 hours, then turn off

(see the figure below)

Your remote display

Timer is set To turn ON

6 hours from current time

Timer is set to turn OFF

8 hours from current time

Unit turns

ON

Unit turns

OFF

2PM 3PM 4PM

6 hours later

8 hours later

5PM 6PM 7PM 8PM 9PM

Handling the remote controller

8m

Location of the remote controller.

Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.

CAUTIONS

The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.

Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.

If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.

If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer.

Do not drop the remote controller. Handle with care.

Do not place heavy objects on the remote controller, or step on it.

Using the remote controller holder

(optional)

The remote controller can be attached to a wall or pillar by using a remote controller holder(not supplied, purchased separately).

Before installing the remote controller, check that the air conditioner receives the signals properly.

Install the remote controller with two screws.

For installing or removing the remote controller, move it up or down in the holder.

Replacing batteries

The following cases signify exhausted batteries.

Replace old batteries with new ones.

Receiving beep is not emitted when a signal

is transmitted.

Indicator fades away.

The remote controller is powed by two dry batteries (R03/LR03X2) housed in the back rear part and protected by a cover.

(1) Remove the back cover of the remote

controller.

(2) Remove the old batteries and insert the new

batteries,placing the(+) and (-) ends correctly.

(3) Install the cover back on.

NOTE: When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed.

CAUTIONS

Do not mix old and new batteries or batteries of different types.

Do not leave the batteries in the remote controller if they are not going to be used for

2 or 3 months.

Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement