Adit 600 Product Guide - AIRLINX Communications, Inc.

Adit 600 Product Guide
Adit 600 R8.0
Item
Broadband Customer Service Terminal which fulfills many channel bank, multiport CSU/DSU, Integrated Access Device,
distributed DLC and Digital Cross-connect applications. Supports up to 18 T1s or E1s, 48 voice channels, 40 ISDN BRI ports,
12 V.35 ports, 24 All-Rate OCU-DP ports, 24 E&M/TO ports. Integrated SNMP and GUI management software.
The most versatile small access platform available.
Part Number
Description
Configured T1 Systems
Adit 600 Base 115/-48V
02-AA1-000000-00
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates
Adit 600 Base +24V
02-AA2-000000-00
+24V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates
8 FXS Ports
02-AA1-200000-00
16 FXS Ports
02-AA1-220000-00
24 FXS Ports
02-AA1-222000-00
32 FXS Ports
02-AA1-222200-00
40 FXS Ports
02-AA1-222220-00
48 FXS Ports
02-AA1-222222-00
Adit 600 Base and 2 V.35 Ports
02-AA1-00000C-00
8 FXS and 2 V.35 Ports
02-AA1-20000C-00
16 FXS and 2 V.35 Ports
02-AA1-22000C-00
24 FXS and 2 V.35 Ports
02-AA1-22200C-00
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates, (1) 8port FXS card
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates, (2) 8port FXS cards
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates, (3) 8port FXS cards
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates,
(4) 8-port FXS cards
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplates,
(5) 8-port FXS cards
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (6) 8-port FXS cards
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates, and
(1) 2-port V.35 Card
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates, (1) 8port FXS card, (1) 2-port V.35 card
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates, (2) 8port FXS cards, (1) 2-port V.35 card
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates, (3) 8port FXS cards, (1) 2-port V.35 card
32 FXS, and 2 V.35 ports
02-AA1-22220C-00
40 FXS, and 2 V.35 ports
02-AA1-22222C-00
16 FXS and Quad T-1 Card
02-AA1-22000E-00
Adit 600 Base with Router
02-AA1-00000H-00
8 FXS Ports and Router
02-AA1-20000H-00
16 FXS Ports and Router
02-AA1-22000H-00
24 FXS Ports and Router
02-AA1-22200H-00
32 FXS Ports and Router
02-AA1-22220H-00
40 FXS Ports and Router
02-AA1-22222H-00
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplate, (4)
8-port FXS cards and (1) Dual V.35 Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (5) 8-port FXS cards and
(1) Dual V.35 Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates,
(2) 8-port FXS cards and (1) Quad T1 Card
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates, and
(1) Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates,
(1) 8-port FXS cards and (1) Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates,
(2) 8-port FXS cards and (1) Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates,
(3) 8-port FXS cards and (1) Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplates,
(4) 8-port FXS cards and (1) Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (5) 8-port FXS cards and
(1) Router Card
Adit 600, 48 FXO
02-AA1-BBBBBB-00
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, and (6) 8-port FXO cards
Adit 600 40 ISDN-BRI Ports
02-AA1-EDDDDD-00
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, (5) Octal ISDN-BRI, 1 Quad
T1
Configured E1 Systems
Adit 600 E1 Base 115/-48V
02-CA1-000000-00
115/-48V Chassis, power supply, Dual E1 TDM controller, SNMP & RPM management, 5 blank card faceplates
6 E1 Ports and Router
02-CA1-LH0000-00
115/-48V Chassis, power supply, Dual E1 TDM controller, SNMP & RPM management, 4 blank card faceplates, (1)
Quad E1 Card and (1) Router Card
Configured VoIP Systems
Adit 600 Base with CMG-02
02-AA1-000003-00
8 FXS Ports with CMG-02
02-AA1-200003-00
16 FXS Ports with CMG-02
02-AA1-220003-00
24 FXS Ports with CMG-02
02-AA1-222003-00
115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates, and
(1) CMG Router Card with 40 g.729 voice channel capacity
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates,
(1) 8-port FXS cards and (1) CMG (g.711, g.726, g.729-40) Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates,
(2) 8-port FXS cards and (1) CMG (g.711, g.726, g.729-40) Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates,
(3) 8-port FXS cards and (1) CMG (g.711, g.726, g.729-40) Card
32 FXS Ports with CMG-02
02-AA1-222203-00
40 FXS Ports with CMG-02
02-AA1-222223-00
Adit 600, 8 FXS, and CMG router
02-AA1-20000M-00
Adit 600, 16 FXS, and CMG router
02-AA1-22000M-00
Adit 600, 24 FXS, and CMG router
02-AA1-22200M-00
Adit 600, 32 FXS, and CMG router
02-AA1-22220M-00
Adit 600, 40 FXS, and CMG router
02-AA1-22222M-00
Adit 600, 8 FXS, and CMG G.729
router
Adit 600, 16 FXS, and CMG G.729
router
Adit 600, 24 FXS, and CMG G.729
router
Adit 600, 32 FXS, and CMG G.729
router
Adit 600, 40 FXS, and CMG G.729
router
02-AA1-20000U-00
02-AA1-22000U-00
02-AA1-22200U-00
02-AA1-22220U-00
02-AA1-22222U-00
Adit 600, 8 FXS, and CMG-01 router
02-AA1-200004-00
Adit 600, 16 FXS, and CMG-01 router
02-AA1-220004-00
Adit 600, 24 FXS, and CMG-01 router
02-AA1-222004-00
Adit 600, 32 FXS, and CMG-01 router
02-AA1-222204-00
Adit 600, 40 FXS, and CMG-01 router
02-AA1-222224-00
Adit 600, 8 FXS, and CMG-01
G.729 router
Adit 600, 16 FXS, and CMG-01
G.729 router
Adit 600, 24 FXS, and CMG-01
G.729 router
02-AA1-200007-00
02-AA1-220007-00
02-AA1-222007-00
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplates,
(4) 8-port FXS cards and (1) CMG (g.711, g.726, g.729-40) Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplates,
(5) 8-port FXS cards and (1) CMG (g.711, g.726, g.729-40) Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates,
(1) 8-port FXS card and (1) CMG Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates,
(2) 8-port FXS cards and (1) CMG Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates,
(3) 8-port FXS cards and (1) CMG Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplate, (4)
8-port FXS cards and (1) CMG Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (5) 8-port FXS cards and
(1) CMG Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates,
(1) 8-port FXS cards and (1) CMG G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates,
(2) 8-port FXS cards and (1) CMG G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates,
(3) 8-port FXS cards and (1) CMG G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplate, (4)
8-port FXS cards and (1) CMG G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (5) 8-port FXS cards and
(1) CMG G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates,
(1) 8-port FXS card and (1) CMG-01 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates,
(2) 8-port FXS cards and (1) CMG-01 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates,
(3) 8-port FXS cards and (1) CMG-01 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplate, (4)
8-port FXS cards and (1) CMG-01 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (5) 8-port FXS cards and
(1) CMG-01 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates,
(1) 8-port FXS cards and (1) CMG-01 G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates,
(2) 8-port FXS cards and (1) CMG-01 G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates,
(3) 8-port FXS cards and (1) CMG-01 G.729 Router Card
Adit 600, 32 FXS, and CMG-01
G.729 router
Adit 600, 40 FXS, and CMG-01
G.729 router
02-AA1-222207-00
02-AA1-222227-00
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplate, (4)
8-port FXS cards and (1) CMG-01 G.729 Router Card
115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (5) 8-port FXS cards and
(1) CMG-01 G.729 Router Card
Components
115/-48V Chassis
02-000-000000-00
Empty 115/-48V Enclosure with backplane and 5 blank card faceplates.
115VAC/-48VDC power supply / battery charger w/ AC cord for 115/-48V Adit 600 Base P/No. 02-AA1-000000-00 and
115/-48V Chassis P/No. 02-000-000000-00
+24VDC Power Supply Card for +24V Adit 600 Base P/No. 02-AA2-000000-01
230V Power Supply
One controller card required per system or chassis. Includes SNMP & RPM management features. Note: Minimum
controller software release required is Rev. 1.2.2
One controller card required per system or chassis. Includes SNMP & RPM management features. Note: Minimum
E1 controller software release required is Rev. 3.2.0
115/-48V Power Supply Card
730-0040
+24VDC Power Supply Card
230V Power Supply
740-0064
740-0082
Dual T1 TDM Controller Card
740-0039
Dual E1 TDM Controller Card
740-0071
CMG VoIP Router Card
740-0070
CMG VoIP Router Card w/G.729ab
740-0089
CMG-01 VoIP Router Card
740-0286
CMG-01 Router Card w/G.729ab-24
740-0284
CMG-02 Router Card-G.729ab-48
740-0238
FXS-8 Card (8B Version)
740-0240
FXS-8 Card (8C Version)
740-0285
Software Key for CMG card - G.729
capability
752-0001
Software upgrade for adding G.729 to the CMG Router Card
Quad Terminal Server Router Card
740-0079
Quad Terminal Server Router Card, Note: Minimum controller software release required is Rev. 4.1
Octal P-phone Card
740-0088
FXO-8 Card
740-0037
Quad DS1/E1 Card
740-0075
CMG Router Card, supporting 16 G.711 - Note: Minimum controller software release required is Rev. 4.0
CMG Router Card with G.729ab low bit rate CODEC support-24 channels Note: Minimum controller software release
required is Rev. 6.1
CMG-01 VoIP Router Card, supporting 24 G.711 channels - Note: Minimum controller software release required is
Rev. 9.4
CMG-01 VoIP Router Card with G.729ab low bit rate CODEC support-24 channels Note: Minimum controller software
release required is Rev. 9.4
CMG Router Card with G.729ab low bit rate CODEC support-48 channels. Note: Physical limitation of the Adit 600 is
40 FXS ports with a CMG module.
8 channel expansion or replacement card for FXS interface applications. Supports GR-909 loop tests.
8 channel expansion or replacement card for FXS interface applications. Supports GR-909 loop tests and CPD.
8-channel P-phone card for Nortel Electronic Business Set (EBS) applications. Note: Minimum controller software
release required is Rev. 6.0.
8 channel expansion or replacement card for FXO or DPT interface applications.
Note: Minimum controller software release required is Rev. 1.2.2
Four channel DS1/E1 card for T1 voice and T1/E1 data applications. Note: Minimum controller software release
required is Rev. 7.0
Dual V.35 Card
740-0038
Two-channel V.35 data card for connecting a router or other data equipment. Requires one V.35 cable (listed below)
per port.
Dual RS-232 Synchronous Data
Card
740-0209
Two-channel RS-232 synchronous data card with V.54 loopback and BERT Test Capability. Note: Minimum controller
software release required is Rev. 5.0
Dual RS-232 Synchronous Data
Card with Adapter Cables
740-0222
Two-channel RS-232 synchronous data card with (2) 005-0166 DB-26M SCSI-to-RJ45 adapter cables. Note:
Minimum controller software release required is Rev. 5.1
Dual ISDN BRI Card
740-0041
Quad ISDN BRI Card
740-0048
Octal ISDN BRI Card
740-0042
10/100 Base-TX Router Card
740-0047
Single Port OCU-DP Card
740-0066
Quad Port OCU-DP Card
740-0067
Quad DS1 ADPCM Card
740-0091
Quad 4-Wire E&M/TO Card
740-0090
Blank Faceplates
710-0011
Two-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release
required is Rev. 1.2.2
Four-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release
required is Rev. 1.2.2
Eight-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release
required is Rev. 1.2.2
Single port router supporting IP/IPX routing and layer 2 bridging. Note: Minimum controller software release required
is Rev. 1.4.1
Single port all rate OCU-DP Card for DDS Service delivery applications. Note: Minimum controller software release
required is Rev. 3.2.0
Quad port all rate OCU-DP Card for DDS Service delivery applications. Note: Minimum controller software release
required is Rev. 3.2.0
Four channel T1 card with 32Kb ADPCM voice compression on Port 1 for voice and data applications. Note:
Minimum controller software release required is Rev. 7.0
Four channel 4-Wire E&M/TO card for voice applications. Note: Minimum controller software release required is
Rev. 8.0
Blank faceplates for empty service card slots.
19" and 23" NEBS CO Rack
Installation Kit
710-0019
NEBS certified 19" and 23" rack mount solution for mounting two Adit 600 chassis side-by-side.
19" and 23" Rack Installation Kit
710-0016
19" and 23" rack mount brackets for mounting two Adit 600 chassis side-by-side, 6-pin mating alarm connector and
ground lug.
Two-conductor DC power
connectors (5 ea.)
790-0004
Mates with -48 DC power connector on rear of Adit 600.
Single Rack Installation Kit
connectors & mounting hardware
790-0006
Contains ground lug, mating DC power and alarm connectors, mounting hardware.
One DC power connector, one
grounding lug
790-0008
Mates with -48 DC power connector and ground studs on rear of Adit 600.
Adit 600 Accessories
Dual T1 TDM Operating System
Update
750-0027
CD ROM for TFTP-loaded field update. Includes SNMP and RPM management.
Manual (CD-ROM)
770-0008
CD ROM version of Adit 600 manual. Included with each Adit 600 system.
Speedway optional 2nd Battery Shelf
710-0025
Optional 2nd battery mounting shelf for Speedway wall mount configurations. (Note: Battery Unit P/N 730-0114 must
be ordered separately)
Speedway dual battery cable
005-0091
Dual battery cable, used when using Speedway Installation Kit and 2nd Battery
Speedway Installation Kit
710-0024
Wall Mount Kit with Swing away brackets for mounting single Adit 600 and power back-up battery. (Note: Battery Unit
P/N 730-0114 must be ordered separately)
Null Modem Adapter
005-0002
25-pin male/25-pin male
Serial Console Cable - 12 ft.
005-0064
12 ft. serial console cable with a DB-9 female and DB-9 male
DB-9 to DB-25 Female Adapter
005-0007
DB-9 to DB-25 female adapter
V.35 Data Cable - 10 ft.
male V.35/male Winchester
005-0008
10 ft. V.35 Data Cable - male V.35 / male Winchester
V.35 Data Cable - 10 ft.
male V.35/female Winchester
005-0014
10 ft. V.35 Data Cable - male V.35 / female Winchester
Installation Connector Kit
Battery Unit
790-0011
730-0114
One 66 block, one T-1 cable, one 10' Amphenol cable
Battery unit for use with Adit 600.
V.35 Data Cable - 25 ft.
male V.35/female Winchester
005-0068
25 ft. V.35 Data Cable - male V.35 / female Winchester
V.35 Data Cable - 50 ft.
male V.35/female Winchester
005-0069
50 ft. V.35 Data Cable - male V.35 / female Winchester
V.35 Data Cable - 25 ft.
male V.35/male Winchester
005-0009
25 ft. V.35 Data Cable - male V.35 / male Winchester
V.35 Data Cable - 50 ft.
male V.35/male Winchester
005-0010
50 ft. V.35 Data Cable - male V.35 / male Winchester
T1 Cable - 25 ft.
005-0101
25 ft. RJ48C-to-RJ48C T1 Straight Cable, RJ45 plug on each end
Ethernet Crossover Cable - 2 ft.
005-0102
2 ft. RJ45-to-RJ45 Ethernet Crossover Cable, RJ 45 plug on each end
Ethernet Straight Cable - 6 ft.
005-0103
6 ft. RJ45-to-RJ45 Ethernet Straight Cable, RJ 45 plug on each end
Universal Accessories
RJ48C-to-DB15P T1 Connector
Adaptor
005-0104
RJ48C-to-DB15P T1 Connector Adaptor
RJ45-to-DB9P Connector Adaptor
005-0105
RJ45-to-DB9P Connector Adaptor - wired with TXD, RXD and SG
RJ45-to-DB9P Connector Adaptor
005-0106
RJ45-to-DB9P Connector Adaptor - wired with control signals
005-0186
6' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches
005-0187
10' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches
005-0188
25' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches
005-0189
50' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches
005-0216
RJ45 Plug on one end, 10 ft. CAT 5 cable, 4 Wire E&M normal mode, 24awg,
005-0217
RJ45 Plug on one end, 10 ft. CAT 5 cable, 4 Wire E&M tandem mode, 24awg,
005-0166
SCSI-26 to RJ-45 Jack adapter cable for Dual RS-232 Synchronous Data card
Grayson LMU V.35 Adapter Cable
Grayson LMU V.35 Adapter Cable
Grayson LMU V.35 Adapter Cable
Grayson LMU V.35 Adapter Cable
E&M Card Interface Cable - Normal
E&M Card Interface Cable Tandem
SCSI-26 to RJ-45 Jack Adapter
cable
Included Items
PORTS
• Two RJ-48C T1 ports with integrated CSUs
• Six service card slots for voice & data cards
• Two RJ-21X 50-pin Tip & Ring connectors
• Power input connector
• Female DB-9 RS-232 Management Port
• Single RJ-45 10BaseT port for Ethernet management
• Six-pin alarm connector - major & minor outputs, one input
• Standard three-conductor IEC Equipment AC Receptacle
ACCESSORIES
• Adit 600 user's manual on CD-ROM
• 6 ft. AC power cord
• Adit 600 five blank card face plates
SOFTWARE
• Adit 600 dual T1 TDM Operating System
POWER OPTIONS
• -48 VDC
• Adit 600 battery charger options are available as noted in the above descriptions.
AIRLINX Communications, Inc.
Box 253
Greenville, NH 03048
E-mail: sales@airlinx.com
Tel: (888) 224-6814
Fax: (603) 878-0530