DNCD450EA/GA—GE Super 7.0 Cu. Ft. Capacity Commercial Dryer

GE Appliances
DNCD450EA/GA—GE Super 7.0 Cu. Ft. Capacity Commercial Dryer
Dryer Dimensions (in inches)
23-1/2
25-3/4
*24-1/2" from the edge of the side panel to the front.
25-1/2" from front to edge of endcaps.
25-1/2*
5-1/4
27
36
42
2-1/2
Side View
Exhaust Options:
Electric: 4-way via rear, right, left and bottom. Maximum recommended exhaust duct length
is 45 feet of 4” rigid ducting with two 90° elbows and a 4” dampered wall cap.
Gas: When viewed from the front of the unit, exhaust 3-way via rear, left and bottom.
Maximum recommended exhaust duct length is 15 feet of 4” rigid ducting with two 90°
elbows and a 4” dampered wall cap.
Circuit Requirements:
An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a
time-delay fuse, is required.
11-1/2
2
Electric Dryer Rating:
208/240V, 5600W, 24A, 60Hz
208V, 4400W, 22A, 60Hz
3-1/2
Rear View
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible
when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed
with your dryer.
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
Specification Revised 2/02
R
Listed by
Underwriters
Laboratories
GE Appliances
DNCD450EA/GA—GE Super 7.0 Cu. Ft. Capacity Commercial Dryer
Dryer Exhausting Information—Use Metal Duct Only
Maximum Length of 4"
Dia. Rigid Metal Duct
Exhaust Hood Type
Maximum Length of 4"
Dia. Flexible Metal Duct
Exhaust Hood Type
Ducting Materials:
For best performance, this dryer should be vented with 4” diameter all rigid metal exhaust duct. If “all rigid metal”
duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended
duct length.
Number
of
90°
Turns
A
4" Opening
B
2-1/2"
Opening
A
4" Opening
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side
or bottom of dryer, add one turn.
0
1
2
3
4
0
1
2
3
0
1
2
3
4
90 ft.
60 ft.
45 ft.
35 ft.
25 ft.
45 ft.
35 ft.
25 ft.
15 ft.
60 ft.
52 ft.
44 ft.
32 ft.
28 ft.
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
30 ft.
20 ft.
10 ft.
—
48 ft.
40 ft.
32 ft.
24 ft.
16 ft.
55 ft.
40 ft.
30 ft.
20 ft.
15 ft.
30 ft.
20 ft.
10 ft.
—
30 ft.
22 ft.
14 ft.
—
—
Best Performance
A
A
4
B
Domestic
Dryer Models
2-1/2
Super & Extra-Large
6.0 Capacity Models
All Electric Dryers
Super & Extra-Large
6.0 Capacity Models
All Gas Dryers
Extra-Large 5.7
Capacity Electric
and Gas Dryers
For complete information, see installation instructions packed with your dryer.
B
2-1/2"
Opening
45 ft.
30 ft.
20 ft.
15 ft.
10 ft.
15 ft.
10 ft.
—
—
18 ft.
14 ft.
10 ft.
—
—
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0” either side
3” front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line.
• No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.
Minimum Clearances other than Alcove or Closet Installation:
•Minimum clearances to combustible surfaces
0” both sides
3” rear
Specification Revised 2/02
2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated is shown
in the table. The maximum length for flexible ducts are less than for rigid duct.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A
turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and
lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard
or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen
exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall
cap must also be located at least 12” above the ground or any other obstruction with the opening pointed Down.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” opening
dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
WWW.GEAppliance.com or call
GE Answer Center® service, 800.626.2000.
R
Listed by
Underwriters
Laboratories
GE Appliances
DNCD450EA/GA—GE Super 7.0 Cu. Ft. Capacity Commercial Dryer
COTTONS
COTTONS :
MIXED LOADS:
KNITS
PERM PRESS :
Commercial
Dryer
MIXED
LOADS
PERM
PRESS
HEAT
SETTINGS
AUTOMATIC SETTINGS
CLOTHES CARE SELECTION
DELICATES
KNITS :
DELICATES :
AIR DRY
DOOR OPEN
AIR DRY :
HIGH HEAT
START
PAUSE
HIGH
HIGH HEAT
MED HEAT
LOW HEAT
MED
STOP
CANCEL
LOW
EXTRA LOW HEAT
NO HEAT
DRYING
COOLDOWN
STATUS
EXTRA
LOW
CLEAN LINT FILTER
Specification Revised 2/02
EST. TIME
REMAINING
Features and Benefits
• Super 7.0 Cu. Ft. Capacity
• 5 Dry Cycles: Cottons (High Heat); Mixed Loads (High Heat); Permanent Press
(Medium Heat); Knits (Low Heat); Delicates (Extra Low Heat)
• 4 Temperatures
• Air Dry
• Digital Cycle Countdown
• Hush Quiet Package
• Lockable Lint Filter
• Reversable Door Swing
• Drum Lamp
• DuraDrum™ Interior
• Model DNCD450EAWC–White
• Model DNCD450GAWC–White
Download PDF