• John Deere® PE6068HFG94 - turbocharged, diesel engine o





















John Deere® PE6068HFG94 - turbocharged, diesel engine
o Prime - 217 hp @ 1800 rpm
o Standby - 241 hp @ 1800 rpm
o 6 cylinder
o 6.8 L displacement
o Interim Tier IV emissions
Steel, single wall fuel tank
o 342 gal. capacity
o 29 hr. run time – full load
o Fuel tank built into skid of generator set
Fuel consumption at prime:
o 100% - 10.9 gph (41.3 Lph)
o 75% - 8.2 gph (31.0 Lph)
o 50% - 5.5 gph (20.8 Lph)
Cooling system capable of operating at 120°F ambient
Low coolant shutdown
Radiator and oil drains plumbed to exterior
Rubber vibration dampers isolate engine/generator from frame
Disposable air filter - paper element
Air filter restriction indicator mounted on control panel
60 Hz engine/generator
Electronic isochronous governing
Utilizes DOC / DPF exhaust filter
Variable Geometry Turbocharger (VGT)
Marathon Electric®
o Brushless
o 4 pole
o Class H insulation
Voltage regulation +/- 1% with Marathon SE350 Voltage Regulator
3 Position voltage selector switch:
o Three phase – 120 / 208V Low Wye
o Three phase – 277 / 480V High Wye
o Single phase – 120 / 240V Zig Zag
153 kW / 191 kVA – standby, three phase
138 kW / 172 kVA – prime, three phase
125 kW / 125 kVA – standby, single phase
120 kW / 120 kVA – prime, single phase
Manufactured by Magnum Power ProductsLLC., a wholly owned subsidiary of Generac Power Systems, Inc.
Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com
Page 1 of 4
1/13
MMG175 Generac Specifications Continued:








Microprocessor-based controller
o Backlit, 128x64 pixel resolution display
o -40°F to 185°F operating temperature range
o Thermostatically controlled LCD heater
o Six LED indicators w/ lamp test
 Alarm / Fault (Red)
 Ready / Manual (Red)
 Running (Green)
 Warning (Yellow)
 Ready / Auto (Green)
 Supplying Load (Green)
Push buttons for easy operation
o Manual or Auto Start
o Engine Start or Stop
o Alarm Cancel & Fault Reset
o Scrolling Arrows for Diagnostic Information
 System kW output display
 Line output & frequency display
 Engine diagnostic display
 Oil pressure
 Engine temperature
 Fuel level
 Battery
 System hours
 Running hours
 kW hours
 Time to service
o Alarm list – warnings / shutdowns are date & time stamped
 Fuel level: warning – 15%; shutdown – 5%
 Overspeed protection: shutdown – 115%
 Oil pressure: warning – 25 psi; shutdown – 20 psi
 Coolant temperature: warning – 220°F; shutdown – 230°F
 Battery voltage: over – 15VDC; under – 11VDC
 Generator over voltage: warning – 110%; shutdown – 111%
 Generator under voltage: warning – 87%; shutdown – 86%
 Generator over frequency: warning – 105%; shutdown – 110%
 Generator under frequency: warning – 95%; shutdown – 90%
 Over current shutdown
Remote start / stop contacts located next to lug box
Lockable control box door with diagnostics window
Lockable lug box with safety switch
o Trips main breaker when lug door is opened
Disables voltage regulator
Cable entry guides to the lug box
o Restricts access of foreign objects
Output ground connection lug inside lug box
700A main breaker with shunt trip
Manufactured by Magnum Power Products LLC., a wholly owned subsidiary of Generac Power Systems, Inc.
Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com
Page 2 of 4
1/13
MMG175 Generac Specifications Continued:


















Convenience receptacles with individual breakers (restricted use in high wye mode)
o (2) 120V 20 Amp GFCI duplex outlets (Nema 5-20R type)
o (3) 125 / 250V 50 Amp, 3 pole, 4 wire twistlock (Non-Nema 6369)
Panel mounted rheostat for voltage adjustment - +/- 10%
1000 CCA wet cell battery
Generac Mobile Power decals
Aluminum, sound attenuated enclosure
o UV & fade resistant, high temperature cured, white polyester powder paint
o Insulated and baffled
o 68 dB(A) at 23 feet – prime power
Fully lockable enclosure including doors and fuel fill
Stainless steel hinges on doors
Emergency stop switch located on outside of enclosure
Central lifting point
Multi-lingual operating/safety decals
Document holder with operating manual including AC/DC wiring diagrams
DOT approved tail, side, brake, and directional lights
o Recessed rear lights
Transportation tie downs
Safety chains with spring loaded safety hooks
3” lunette ring hitch
(2) 7000 lb. axles with surge brakes
5000 lb. tongue jack with footplate
ST235/80R16 tubeless tires – 10 ply
Skid mounted
 Dry weight: 6604 lbs (2996 kg)
 Operating weight: 9032 lbs (4097 kg)
 144 x 50 x 77 in
(3.66 x 1.27 x 1.96 m)
Trailer mounted
 Dry weight: 8000 lbs
(3629 kg)
 Operating weight: 10426 lbs (4730 kg)
 210 x 86 x 93 in
(5.33 x 2.18 x 2.36 m)

Engine and generator covered under OEM warranty – consult factory for details.

CSA certified
Manufactured by Magnum Power Products LLC., a wholly owned subsidiary of Generac Power Systems, Inc.
Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com
Page 3 of 4
1/13
MMG175 Generac Specifications Continued:


In-line engine block heater (Kim Hotstart)
Fuel transfer pump


Battery disconnect
Battery charger – 2A trickle


PMG Generator - critical grade power quality
SUPERSTART™ Generator - motor starting applications
 157 kW / 157 kVA – standby, single phase
 143 kW / 143 kVA – prime, single phase
 161 kW / 201 kVA – standby, three phase
 145 kW / 181 kVA – prime, three phase




4 position phase switch
 Single phase – 120 / 240V Zig Zag
 Three phase – 120 / 208V Low Wye
 Three phase – 277 / 480V High Wye
 Three phase – 120 / 240V Delta
Dedicated voltage configurations
Buck Transformer kit - Provides 120V at GFCI outlets when in 277/480V
Cam locks

Auxiliary strobe/audible indication for soft & hard alarm conditions

60/40 Coolant - cold weather applications


Fire extinguisher
Interior cabinet light
 Control panel light

120% Containment

Tandem axle trailer w/ electric brakes
 6 pin or 7 spade electrical connectors
 Spare tire/wheel kit
Manufactured by Magnum Power Products LLC., a wholly owned subsidiary of Generac Power Systems, Inc.
Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com
Page 4 of 4
1/13