FA Goods General Catalog Devices for wire saving and process

June 2013 Edition
FA Goods General Catalog
Devices for wire saving and process time reduction
For MELSEC-Q/L/AnS Series Programmable Controllers
and CC-Link Modules
Interface Module for DC I/O
Conversion Module for DC I/O
Page 1-1
Conversion Module for Analog I/O
Page 2-1
Conversion Module for High-Speed Counter
Page 3-1
Cable for Positioning Module
Page 4-1
Conversion Module for MELSEC-L CPU
Page 5-1
Page 6-1
FA goods are highly reliable wire-saving devices that are
used in the wiring work of Mitsubishi general-purpose
programmable controllers!!
Before
Conventional wiring
Q 2CPU
QX41
QX41P
QH42P
Q68ADV
Q62AD DGH
Q64TD
Q68DAVN
QD62
After
With FA goods
Q0 CPU
QX41
QX41P
QH42P
Q68ADV
Q68DAVN
QD62
20
0 1 2 3 4 5 6 7 8 9 A B C D E F 10 1 12 1 14 15 6 17 18 9 1A B 1C 1D E 1F PW
PW
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
FA TH16X100A31
AC10 V n ut m du e
PW
FALTB20P
1
1
2
3
3
2
2
0
1
4
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
9
5
5
6
7
7
8
9
10
9
11
11
12
3
3
14
15
15
6
17
17
18
19
20
19
The above illustration is an image of the introduction of FA goods.
FA goods reduce the process time required for the wiring work for the inside
and outside of the panel of programmable controllers, reduce wiring errors,
and ensure high reliability in safety.
As an interface between programmable controllers and external I/O devices,
FA goods further enhance the extensibility of programmable controllers.
Screw terminal block
Connector
Discrete cable
DC
Interface Module for DC I/O
input type
Chapter
Analog
Interface Module for DC I/O
output type
Chapter
2
DC electromagnetic
AC relays, etc.
switches, etc.
24VDC
Chapter
Conversion Module
for Analog I/O
3
Connector
4
4
D/A
Chapter
Measuring
devices, etc.
Screw terminal block
Thermocouple
input
Pulse
Inverters, etc.
A/D
Resistance
temperature
detector input
Conversion Module
For High-Speed Counter
3
NO contact relay
Temperature
regulation
Conversion module
for high-speed counter
Speed control
Pulse generators, etc.
Connector
Cable For
Positioning Module
Positioning
24VDC relay
24VDC
High-speed counter
MELSEC-Q series
MELSEC-L series
MELSEC-AnS series
Programmable controller
DC switches, AC/DC limit
etc.
switches, etc.
2
I/O
2
Conversion Module
For DC I/O
DC switches, DC pilot lamps,
etc.
etc.
1
Spring clamp
terminal block
Interface Module For DC I/O
1
Conversion Module
For Analog I/O
Conversion Module
for DC I/O
Chapter
Chapter
5
Cable for Positioning
Module
Servo amplifiers,
etc.
Motors, etc.
Discrete cable
Chapter
6
Conversion Module
for MELSEC-L CPU
Motors, etc.
(Built-in I/O function)
Connector
Screw terminal block
Servo amplifiers,
etc.
7
MELSEC-L CPU module
with built-in I/O function
Common Elements
& Appendix
6
Connector
Conversion Module
For MELSEC-L CPU
5
Discrete cable
1. Conversion Module for DC I/O
Conversion Module
For DC I/O
Conversion Modules (DC Dedicated)
Contents
1
Interface Module For DC I/O
2
Conversion Module
For Analog I/O
3
Conversion Module
For High-Speed Counter
4
Cable For
Positioning Module
5
Conversion Module
For MELSEC-L CPU
6
Common Elements
& Appendix
7
1-Contents
Selection Chart
Overview
Overview
1-1
Model List
Screw Terminal Block
1-2
Spring Clamp Terminal Block
1-2
Discrete Cable
1-2
Module-to-Module Cable
1-3
MELSEC-Q Series
1-5,6
MELSEC-L Series
1-7
MELSEC-AnS Series
1-8,9
Mitsubishi Electric CC-Link Remote I/O
1-10
Individual Specifications
Screw Terminal Block
Spring Clamp Terminal Block
Discrete Cable
Module-to-Module Cable
1-11 to 14
1-15, 16
1-17
1-17 to 21
7
Common Elements
& Appendix
6
Conversion Module
For MELSEC-L CPU
5
Cable For
Positioning Module
4
Conversion Module
For High-Speed Counter
3
Conversion Module
For Analog I/O
2
Interface Module For DC I/O
1
Conversion Module
For DC I/O
1. Conversion Module for DC I/O
1-Contents
1. Conversion Module for DC I/O
Overview
Overview
Conversion Module
For DC I/O
Using a DC I/O conversion module as a relay terminal block of the control panel allows you to significantly reduce the process time required for
wiring work to connector-type I/O modules of the programmable controller.
There are two types of conversion modules: MELSEC dedicated conversion modules and a general-purpose conversion module connectable to
programmable controllers manufactured by other companies.
1
Connector
assembly
Connector Wires
One-touch
connection
using cable with
connector
Wiring to
terminals
Wiring to
terminals
Typ e s of Conversi ons
● Screw terminal block type
● Spring clamp terminal block type
A screw terminal block (with spring-up,
fall-prevention screws) is used for the
wiring of the connector type I/O module of
programmable controller.
The FA goods spring-up, fall-prevention
screws facilitate wiring by using round
solderless terminals without falling off of the
screws even if the screws are loosened.
Finger protection
Terminal block
1-1
Model List
1-2
to
1-3
A spring clamp terminal block is used for the
wiring of the connector type I/O module of
programmable controller.
The spring clamp terminal block is resistant
to vibrations with high reliability because a
tension is always applied to the terminal
area.
Just push down the buttons on the terminal
block to insert/extract the wires.
Spring-up screw
Round solderless
terminal
Model Selection
1-5
to
1-10
Individual Specifications
1-11
to
1-21
● Discrete cable type
A discrete cable is used for the wiring of
the connector type I/O module of
programmable controller, a discrete
cable is used.
The cable has an unprocessed end
because the cable is directly connected
to a device (load, relay terminal, etc.).
1. Conversion Module for DC I/O
Model List
Screw Terminal Block
Product
For connectable I/O modules and cables, see the Selection Chart.
Shape
Model
Device number (Note 1)
Remarks
Page
• Used for the MELSEC connector type I/O module
• Ideal for combined use with terminal modules
• Common to input/output (target I/O is selected using the applicable cable)
MELSEC-dedicated
16-point 1-wire type module
FA-TB16XY
For X0 to XF/Y0 to YF
MELSEC-dedicated
32-point 1-wire type module
FA-TB32XY
For X0 to X1F/Y0 to Y1F
• Used for the MELSEC connector type I/O module
• Common to input/output (target I/O is selected using the applicable cable)
1-11
MELSEC-dedicated
small-size
32-point 1-wire type module
FA-TBS32XY
For X0 to X1F/Y0 to Y1F
• Small-size conversion module for the MELSEC connector type I/O module
• Common to input/output (target I/O is selected using the applicable cable)
1-12
For X0 to X1F/Y0 to Y1F
• Used for the MELSEC connector type I/O module
• Common to input/output (target I/O is selected using the applicable cable)
• Allows verification of the I/O status by the LED display of the conversion
module
• FA-TB32XYL…..Positive common input / sink output compatible
• FA-TB32XYH…..Negative common input / source output compatible
1-12
1
1-11
Conversion Module
For DC I/O
Model List 1
FA-TB32XYL
(Sink type)
MELSEC-dedicated
32-point 1-wire type module
with LED display
FA-TB32XYH
(Source type)
FA-TB16XY1
MELSEC-dedicated
16-point 3-wire
distributed type module
FA-TB16XY2
General-purpose
small-size 40-point module
FA-TBS40P
Connector covers
(for MIL40P connector)
FA-CAP40MIL10
• 16-point distributed-type module used for the MELSEC connector type I/O
module
• Common to input/output (target I/O is selected using the applicable cable)
• Connects distributed modules to each other using FA-CBL**MMH
• Allows modules to be separately arranged in units of 16 points
• Designed as a 3-wire type; does not require a common terminal during load
For X10 to X1F/Y10 to Y1F connection, etc.
• Shares one common terminal between two X/Y points
For X0 to XF/Y0 to YF
1-13
−
• General-purpose small-size terminal block for 40-point signal
• Applicable to the programmable controller I/Os of other companies
• Uses a general-purpose cable for connection with the programmable
controllers of other companies
1-14
−
• Option for the FA-TB16XY1/FA-TB16XY2 distributed type module
• Covers for preventing the contamination of unused connectors by foreign
matter
• Includes 10 covers
1-14
Note 1: X* and Y* indicate the MELSEC I/O input and output device numbers.
Spring Clamp Terminal Block
Product
For connectable I/O modules and cables, see the Selection Chart.
Shape
MELSEC-dedicated
32-point 1-wire type module
Model
Remarks
FA-TE32XY
For X0 to X1F/Y0 to Y1F
Page
• MELSEC connector I/O module dedicated spring clamp terminal block for
32 points.
• The spring clamp terminal block makes it possible to connect wiring by
pressing and releasing a release button using a general-purpose Phillips
or flathead screwdriver.
1-15
Note: X* and Y* indicate the MELSEC I/O input and output device numbers.
Discrete Cable
Product
Vertical, round 40-core cable for
the programmable controller I/O
modules of other companies
For connectable I/O modules and cables, see the Selection Chart.
Shape
Model
Remarks
FA-CBL20FV
2m (78.75 inch)
FA-CBL30FV
3m (118.12 inch)
FA-CBL50FV
5m (196.86 inch)
(FCN40P connector on one side)
Model Selection MELSEC-Q
1-5
Page
• This cable comes out vertically from the programmable controller
connector-type I/O module of other companies. (FCN 40P connector on
the programmable controller side and a discrete cable on the other side)
1-6
MELSEC-L
1-7
MELSEC-AnS
1-8
1-9
CC-Link
1-17
1-10
1-2
1. Conversion Module for DC I/O
Model List
Model List 2
Conversion Module
For DC I/O
Module-to-Module Cable
Product
For connectable I/O modules and cables, see the Selection Chart.
Shape
Model
Remarks
FA-CBL10FMV
1m (39.38 inch)
1
• This cable is used for connecting a MELSEC-Q/AnS series FCN 40P
connector-type I/O module and a MELSEC-dedicated 32-point conversion
module.
• The 40-core cable is vertically comes out from the MELSEC-Q/AnS series FCN
3m (118.12 inch) 40P connector-type I/O module.
• The cable cannot be used with general-purpose 40P conversion modules.
FA-CBL20FMV
Vertical round 40-core cable for
MELSEC-dedicated I/O module
2m (78.75 inch)
FA-CBL30FMV
FA-CBL50FMV
5m (196.86 inch)
FA-CBL10FM2V
1m (39.38 inch)
• This cable comes out out from the MELSEC-Q/AnS series FCN 40P
connector-type I/O module with a round 40-core cable, branching into two MIL
20P connectors on the other cable end, each connecting to a
MELSEC-dedicated 16-point conversion module.
• The 40-core cable is vertically comes out from the MELSEC-Q/AnS series FCN
3m (118.12 inch)
40P connector-type I/O module.
• The cable cannot be used with general-purpose 20P conversion modules.
5m (196.86 inch)
FA-CBL20FM2V
Vertical branch cable for
MELSEC-dedicated I/O module
FA-CBL50FM2V
1m (39.38 inch) • This cable is used to connect a MELSEC-Q/AnS series FCN 40P
connector-type negative common input module and a MELSEC-dedicated
32-point conversion module.
2m (78.75 inch) • The 40-core cable is vertically comes out from the MELSEC-Q/AnS series FCN
40P connector-type I/O module.
3m (118.12 inch) • The cable cannot be used with general-purpose 40P conversion modules.
FA-CBL10FMVE
FA-CBL20FMVE
FA-CBL30FMVE
Horizontal round 40-core cable
(D-Sub connector type) for
MELSEC-dedicated negative
common type input module
Horizontal round 40-core cable
(D-Sub connector type) for
MELSEC-dedicated source
output module
Horizontal round 40-core cable
for connection between
distributed-type conversion
modules (MELSEC-dedicated)
or for connection between
various controllers and a
general-purpose 40P conversion
module (general-purpose)
Dedicated vertical round
40-core cable for connection
between Mitsubishi Electric I/O
module and general-purpose
40P connector terminal block
conversion module
Model Selection MELSEC-Q
1m (39.38 inch)
FA-CBL20DMFX
2m (78.75 inch)
FA-CBL50DMFX
5m (196.86 inch)
FA-CBL10DMFY
1m (39.38 inch)
FA-CBL20DMFY
2m (78.75 inch)
FA-CBL50DMFY
5m (196.86 inch)
FA-CBL05MMH
0.5m (19.69 inch)
1-5
1-6
MELSEC-L
FA-CBL50MMH
5m (196.86 inch)
FA-CBL10FMH
1m (39.38 inch)
FA-CBL20FMH
2m(78.75 inch)
FA-CBL30FMH
3m (118.12 inch)
FA-CBL10FM2H
1m (39.38 inch)
FA-CBL20FM2H
2m (78.75 inch)
FA-CBL30FM2H
3m (118.12 inch)
FA-CBL10FMV-M
1m (39.38 inch)
FA-CBL20FMV-M
2m (78.75 inch)
FA-CBL30FMV-M
3m (118.12 inch)
1-7
MELSEC-AnS
1-8
1-9
1-18
1-18
• This cable is used to connect a MELSEC-Q/AnS series D-Sub 37P
connector-type negative common input module and a MELSEC dedicated
32-point conversion module.
• The cable cannot be used with general-purpose 40P conversion modules.
1-19
• This cable is used to connect a MELSEC-Q/AnS series D-Sub 37P connector
source-type output module and a MELSEC dedicated 32-point conversion
module.
• The cable cannot be used with general-purpose 40P conversion modules.
1-19
1m (39.38 inch) • This cable is used to connect distributed-type conversion modules.
• The cable is used to connect the MIL 40P connector of various controllers and a
2m (78.75 inch) general-purpose 40P conversion module.
FA-CBL20MMH
Horizontal branch cable for
Mitsubishi Electric CC-Link
remote I/O module
1-3
FA-CBL10DMFX
FA-CBL10MMH
Horizontal round 40-core cable
for Mitsubishi Electric CC-Link
remote I/O module
1-17
2m (78.75 inch)
FA-CBL30FM2V
Vertical round 40-core cable
(FCN connector type) for
MELSEC-dedicated negative
common type input module
Page
1-20
• This cable is used to connect a Mitsubishi Electric CC-Link remote I/O module
that uses an FCN 40P connector and a MELSEC-dedicated 32-point conversion
module.
1-20
• This cable leads out from the Mitsubishi Electric CC-Link FCN 40P
connector-type remote I/O module with a round 40-core cable , branching into
two MIL 20P connectors on the other cable end, each connecting to a
MELSEC-dedicated 16-point conversion module.
1-21
• This cable is used to connect a Mitsubishi Electric programmable controller FCN
40P connector-type I/O module and a general-purpose 40P conversion module.
• The cable cannot be connected to a MELSEC-dedicated 32-point conversion
module.
1-21
CC-Link
1-10
1
Conversion Module
For DC I/O
1. Conversion Module for DC I/O
1-4
1. Conversion Module for DC I/O
Selection Chart
MELSEC-Q Series Selection Chart 1
Conversion Module
For DC I/O
Programmable Controller ↔ Conversion Module
● Connection example: Connector type I/O module
↔ Conversion module
QX42 + FA-CBL10FMV × 2 + FA-TB32XY × 2
● Connection example: Connector type I/O module
↔ Distributed-type conversion module
QX41 + FA-CBL10FMV + FA-TB16XY1
+ FA-CBL10MMH + FA-TB16XY2
1
Input/
Output
Programmable controller
module model
Conversion module type
Distributed 16-point
QX41
QX41-S1
QX41-S2
QX42
QX42-S1
QX71
(Notes 3 and 4)
QX72
(Notes 3 and 4)
Input
Screw terminal block
Positive
common
dedicated
Negative
common
dedicated
Common
QX81
QX81-S2
LED
Spring clamp terminal block
Screw terminal block
Discrete cable
Distributed 16-point
Screw terminal block
Spring clamp terminal block
Distributed 16-point
Screw terminal block
Spring clamp terminal block
Screw terminal block
Discrete cable
Distributed 16-point
Screw terminal block
LED
Spring clamp terminal block
Distributed 16-point
Screw terminal block
QX82
QX82-S1
QY41P (Note 4)
QY42P (Note 4)
QY71 (Notes 3 and 4)
Output
QY81P (Note 4)
LED
Spring clamp terminal block
Screw terminal block
Discrete cable
Distributed 16-point
Screw terminal block
LED
Spring clamp terminal block
Screw terminal block
Discrete cable
Distributed 16-point
Screw terminal block
LED
Spring clamp terminal block
Distributed 16-point
Screw terminal block
QY82P (Note 4)
LED
Spring clamp terminal block
Screw terminal block
Discrete cable
Distributed 16-point
Screw terminal block
Combined
QH42P
QX41Y41P (Note 4)
LED
Spring clamp terminal block
Screw terminal block
Discrete cable
Conversion module model
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
1-wire type FA-TB32XYL
FA-TE32XY
FA-TBS40P
(Note 1)
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
FA-TE32XY
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
FA-TE32XY
FA-TBS40P
(Note 1)
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
1-wire type FA-TB32XYH
FA-TE32XY
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
1-wire type FA-TB32XYH
FA-TE32XY
FA-TBS40P
(Note 1)
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
1-wire type FA-TB32XYL
FA-TE32XY
FA-TBS40P
(Note 1)
(Note 1)
(Note 2)
(Note 1)
(Note 1)
(Note 2)
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
1-wire type FA-TB32XYH
FA-TE32XY
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
1-wire type FA-TB32XYH
FA-TE32XY
FA-TBS40P
(Note 1)
3-wire type FA-TB16XY1, 2
FA-TB32XY
1-wire type
FA-TBS32XY
1-wire type FA-TB32XYL
FA-TE32XY
FA-TBS40P
(Note 1)
Note 1: For a module-to-module cable, use FA-CBL**MMH. Use the same power supply for the modules.
Note 2: For use with 24VDC only.
Note 3: When used with 5VDC, connect the 5VDC to a 24VDC terminal.
Note 4: When used with 12VDC, connect the 12VDC to a 24VDC terminal.
1-5
(Note 2)
(Note 2)
(Note 1)
(Note 2)
(Note 2)
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-15
1-13
1-11
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-14
Connection cable
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMV
1-17
FA-CBL**FMVE
1-18
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**DMFX
1-19
FA-CBL**FMVE
1-18
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**DMFY
1-19
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
1. Conversion Module for DC I/O
Selection Chart
Conversion Module
For DC I/O
MELSEC-Q Series Selection Chart 2
Programmable Controller ↔ Conversion Module + Conversion Module
● Connection example: Connector type I/O module ↔ Screw terminal block conversion
QY41P + FA-CBL10FM2V + FA-TB16XY + FA-TB16XY
FA-TB16XY
1
FA-TB16XY
Input/
Output
Input
Output
Combined
Programmable controller
module model
QX41
QX41-S1
QX41-S2
QX42
QX42-S1
QX71
QX72
QY41P
QY42P
QY71
QY82P
QH42P
QX41Y41P
(Notes 2, 3, and 4)
(Notes 2, 3, and 4)
(Note 3)
(Note 3)
(Notes 2 and 3)
(Note 3)
(Note 3)
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Note 1: For two connected modules, use the same power supply.
Note 2: When used with 5VDC, connect the 5VDC to a 24VDC terminal.
Note 3: When used with 12VDC, connect the 12VDC to a 24VDC terminal.
Note 4: Applicable with a positive common.
MELSEC-Q Series Selection Chart 3
Programmable Controller ↔ Conversion Module + Interface Module
● Connection example: Connector type I/O module ↔ Conversion module + Interface module
QY41P + FA-CBL10FM2V + FA-TB16XY + FA-TH16YRA20S
FA-TB16XY
FA-TH16YRA20S
Input/
Output
Input
Output
Programmable controller
module model
QX41
QX41-S1
QX41-S2
QX42
QX42-S1
QY41P (Note 2)
QY42P (Note 2)
Input side
Combined
QH42P (Note 2)
Output side
QX41Y41P
Conversion module type
Conversion module model 1
Screw terminal block
1-wire type
FA-TB16XY
1-11
Screw terminal block
1-wire type
FA-TB16XY
1-11
Screw terminal block
1-wire type
FA-TB16XY
1-11
Screw terminal block
1-wire type
FA-TB16XY
1-11
Conversion module model 2
FA-TH16XRA20S
2-13
FA-TH16YRA11S
FA-TH16YRA20S
FA-TH16XRA20S
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
2-13
2-14
2-15
Connection cable
FA-CBL**FM2V
(Note 1)
1-18
FA-CBL**FM2V
(Note 1)
1-18
FA-CBL**FM2V
(Note 1)
1-18
FA-CBL**FM2V
(Note 1)
1-18
Note 1: For two connected modules, use the same power supply.
Note 2: For use with 24VDC only.
1-6
1. Conversion Module for DC I/O
Selection Chart
MELSEC-L Series Selection Chart 1
Conversion Module
For DC I/O
Programmable Controller ↔ Conversion Module
● Connection example: Connector type I/O module
↔ Conversion module
LX42C4 + FA-CBL10FMV × 2 + FA-TB32XY × 2
● Connection example: Connector type I/O module
↔ Distributed-type conversion module
LY41NT1P + FA-CBL10FMV + FA-TB16XY1
+ FA-CBL10MMH + FA-TB16XY2
1
Input/
Output
Programmable controller
module model
Conversion module type
Conversion module model
Distributed 16-point 3-wire type
Positive
common
dedicated
Input
LX41C4
LX42C4
Negative
common
dedicated
Common
Screw terminal block
1-wire type
LED
1-wire type
Spring clamp terminal block
Distributed 16-point 3-wire type
Screw terminal block
1-wire type
LED
1-wire type
Spring clamp terminal block
Screw terminal block
Discrete cable
Distributed 16-point 3-wire type
Screw terminal block
LY41NT1P
LY42NT1P
1-wire type
LED
1-wire type
Spring clamp terminal block
Screw terminal block
Discrete cable
Distributed 16-point 3-wire type
Output
LY41PT1P
LY42PT1P
Screw terminal block
1-wire type
LED
Spring clamp terminal block
Screw terminal block
Discrete cable
1-wire type
FA-TB16XY1, 2
FA-TB32XY
FA-TBS32XY
FA-TB32XYL
FA-TE32XY
FA-TB16XY1, 2
FA-TB32XY
FA-TBS32XY
FA-TB32XYH
FA-TE32XY
FA-TBS40P
(Note 1)
FA-TB16XY1, 2
FA-TB32XY
FA-TBS32XY
FA-TB32XYL
FA-TE32XY
FA-TBS40P
(Note 1)
FA-TB16XY1, 2
FA-TB32XY
FA-TBS32XY
FA-TB32XYH
FA-TE32XY
FA-TBS40P
(Note 1)
(Note 2)
(Note 1)
(Note 2)
(Note 2)
(Note 2)
1-13
1-11
1-12
1-12
1-15
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-14
Connection cable
FA-CBL**FMV
1-17
FA-CBL**FMVE
1-18
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
Note 1: For a module-to-module cable, use FA-CBL**MMH. Use the same power supply for the modules.
Note 2: For use with 24VDC only.
MELSEC-L Series Selection Chart 2
Programmable Controller ↔ Conversion Module + Conversion Module
● Connection example: Connector type I/O module ↔ Screw terminal block
LX41C4 + FA-CBL10FM2V + FA-TB16XY + FA-TB16XY
FA-TB16XY
FA-TB16XY
Input/
Output
Input
Output
Programmable controller
module model
LX41C4
LX42C4
LY41NT1P
LY42NT1P
LY41PT1P
LY42PT1P
Positive common
dedicated
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
Note 1: For two connected modules, use the same power supply.
MELSEC-L Series Selection Chart 3
Programmable Controller ↔ Conversion Module + Interface Module
● Connection example: Connector type I/O module ↔ Conversion module + Interface module
LY41NT1P + FA-CBL10FM2V + FA-TB16XY + FA-TH16YRA20S
FA-TB16XY
FA-TH16YRA20S
Input/
Output
Input
Output
Programmable controller
module model
Conversion module type
Positive common
LX41C4
Screw terminal block
dedicated
LX42C4
LY41NT1P (Note 2)
Screw terminal block
LY42NT1P (Note 2)
Note 1: For two connected modules, use the same power supply.
Note 2: For use with 24VDC only.
1-7
Conversion module model
Interface module model
Connection cable
1-wire type
FA-TB16XY
1-11
FA-TH16XRA20S
2-13
FA-CBL**FM2V
(Note 1)
1-18
1-wire type
FA-TB16XY
1-11
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2V
(Note 1)
1-18
1. Conversion Module for DC I/O
Selection Chart
Conversion Module
For DC I/O
MELSEC-AnS Series Selection Chart 1
Programmable Controller ↔ Conversion Module
● Connection example: Connector type I/O module
↔ Distributed-type conversion module
A1SX41 + FA-CBL10FMV + FA-TB16XY1
+ FA-CBL10MMH + FA-TB16XY2
1
● Connection example: Connector type I/O module
↔ Conversion module
A1SX42 + FA-CBL10FMV × 2 + FA-TB32XY × 2
Input/
Output
Input
Output
Combined
Programmable controller
module model
Conversion module type
Conversion module model
Distributed 16-point 3-wire type FA-TB16XY1, 2
A1SX41
(Note 4)
FA-TB32XY
A1SX41-S1
Screw terminal block
1-wire type
FA-TBS32XY
A1SX41-S2
LED
1-wire type FA-TB32XYL
A1SX42
(Note 4)
Spring clamp terminal block
FA-TE32XY
A1SX42-S1
Screw terminal block
FA-TBS40P
A1SX42-S2
Discrete cable
Distributed 16-point 3-wire type FA-TB16XY1, 2
Positive
Screw terminal block
FA-TB32XY
1-wire type
common
FA-TBS32XY
dedicated
Spring clamp terminal block
FA-TE32XY
A1SX71
Distributed 16-point 3-wire type FA-TB16XY1, 2
Negative
(Notes 3 and 4)
Screw terminal block
FA-TB32XY
1-wire type
common
FA-TBS32XY
dedicated
Spring clamp terminal block
FA-TE32XY
Screw terminal block
FA-TBS40P
Common
Discrete cable
Distributed 16-point 3-wire type FA-TB16XY1, 2
FA-TB32XY
A1SX81
(Note 4)
Screw terminal block
1-wire type
FA-TBS32XY
A1SX81-S2
LED
1-wire type FA-TB32XYH
Spring clamp terminal block
FA-TE32XY
Distributed 16-point 3-wire type FA-TB16XY1, 2
FA-TB32XY
Screw terminal block
1-wire type
FA-TBS32XY
A1SX82-S1
LED
1-wire type FA-TB32XYH
Spring clamp terminal block
FA-TE32XY
Screw terminal block
FA-TBS40P
Discrete cable
Distributed 16-point 3-wire type FA-TB16XY1, 2
FA-TB32XY
Screw terminal block
1-wire type
A1SY41P (Note 4)
FA-TBS32XY
A1SY42P (Note 4)
LED
1-wire type FA-TB32XYL
A1SY71
(Notes 3 and 4) Spring clamp terminal block
FA-TE32XY
Screw terminal block
FA-TBS40P
Discrete cable
Distributed 16-point 3-wire type FA-TB16XY1, 2
FA-TB32XY
Screw terminal block
1-wire type
A1SY81
(Note 4)
FA-TBS32XY
LED
1-wire type FA-TB32XYH
Spring clamp terminal block
FA-TE32XY
Distributed 16-point 3-wire type FA-TB16XY1, 2
FA-TB32XY
Screw terminal block
1-wire type
FA-TBS32XY
A1SY82
(Note 4)
LED
1-wire type FA-TB32XYH
Spring clamp terminal block
FA-TE32XY
Screw terminal block
FA-TBS40P
Discrete cable
Distributed 16-point 3-wire type FA-TB16XY1, 2
FA-TB32XY
A1SH42
(Note 4)
Screw terminal block
1-wire type
FA-TBS32XY
A1SH42-S1
LED
1-wire type FA-TB32XYL
A1SH42P (Note 4)
Spring clamp terminal block
FA-TE32XY
A1SH42P-S1
Screw terminal block
FA-TBS40P
Discrete cable
(Note 1)
(Note 2)
(Note 1)
(Note 1)
(Note 1)
(Note 2)
(Note 1)
(Note 2)
(Note 1)
(Note 2)
(Note 1)
(Note 2)
(Note 1)
(Note 2)
(Note 1)
(Note 2)
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-15
1-13
1-11
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-13
1-11
1-12
1-12
1-15
1-14
1-13
1-11
1-12
1-12
1-15
1-14
Connection cable
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMVE
1-18
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**DMFX
1-19
FA-CBL**FMVE
1-18
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**DMFY
1-19
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
FA-CBL**FMV
1-17
FA-CBL**FMV-M
FA-CBL**FV
1-21
1-17
Note 1: For a module-to-module cable, use FA-CBL**MMH. Use the same power supply for the modules.
Note 2: For use with 24VDC only.
Note 3: When used with 5VDC, connect the 5VDC to a 24VDC terminal.
Note 4: When used with 12VDC, connect the 12VDC to a 24VDC terminal.
1-8
1. Conversion Module for DC I/O
Selection Chart
MELSEC-AnS Series Selection Chart 2
Conversion Module
For DC I/O
Remote I/O ↔ Conversion Module + Conversion Module
● Connection example: Connector type I/O module ↔ Screw terminal block
A1SY41P + FA-CBL10FM2V + FA-TB16XY + FA-TB16XY
FA-TB16XY
FA-TB16XY
1
Input/
Output
Input
Output
Combined
Programmable controller
module model
A1SX41
A1SX41-S1
A1SX41-S2
A1SX42
A1SX42-S1
A1SX42-S2
A1SX71
A1SY41P
A1SY42P
A1SY71
A1SY82
A1SH42
A1SH42-S1
A1SH42P
A1SH42P-S1
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
(Note 3)
(Note 3)
(Notes 2, 3, and 4)
(Note 3)
(Note 3)
(Notes 2 and 3)
(Note 3)
(Note 3)
(Note 3)
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2V
(Note 1)
1-18
Note 1: For two connected modules, use the same power supply.
Note 2: When used with 5VDC, connect the 5VDC to a 24VDC terminal.
Note 3: When used with 12VDC, connect the 12VDC to a 24VDC terminal.
Note 4: A1SX71 is positive common dedicated.
MELSEC-AnS Series Selection Chart 3
Remote I/O ↔ Conversion Module + Interface Module
● Connection example: Connector type I/O module ↔ Conversion module + Interface module
A1SY41P + FA-CBL10FM2V + FA-TB16XY + FA-TH16YRA20S
FA-TB16XY
FA-TH16YRA20S
Input/
Output
Input
Output
Combined
Programmable controller
module model
A1SX41
A1SX41-S1
A1SX41-S2
A1SX42
A1SX42-S1
A1SX42-S2
A1SY41P
A1SY42P
A1SH42
A1SH42-S1
A1SH42P
A1SH42P-S1
Conversion module type
(Note 2)
(Note 2)
(Note 2)
(Note 2)
(Note 2)
(Note 2)
(Note 2)
Input side
Screw terminal block
1-wire type
FA-TB16XY
1-11
Screw terminal block
1-wire type
FA-TB16XY
1-11
Screw terminal block
1-wire type
FA-TB16XY
1-11
Output side Screw terminal block
Note 1: For two connected modules, use the same power supply.
Note 2: For use with 24VDC only.
1-9
Conversion module model
Interface module model
Connection cable
(Note 2)
1-wire type
FA-TB16XY
1-11
FA-TH16XRA20S
2-13
FA-TH16YRA11S
FA-TH16YRA20S
FA-TH16XRA20S
2-14
2-15
2-13
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2V
(Note 1)
1-18
FA-CBL**FM2V
(Note 1)
1-18
FA-CBL**FM2V
(Note 1)
1-18
FA-CBL**FM2V
(Note 1)
1-18
1. Conversion Module for DC I/O
Selection Chart
Remote I/O ↔ Conversion Module
● Connection example: Remote I/O module ↔ Distributed-type conversion module
AJ65SBTCF1-32T + FA-CBL10FMH + FA-TB16XY1 + FA-CBL10MMH + FA-TB16XY2
1
● Connection example: Remote I/O module ↔ Conversion module
AJ65SBTCF1-32D + FA-CBL10FMH + FA-TB32XY
Conversion Module
For DC I/O
Mitsubishi Electric CC-Link Remote I/O Selection Chart 1
Input/
Output
Programmable controller
module model
Conversion module type
Distributed 16-point
Input
Output
AJ65SBTCF1-32D
AJ65BTC1-32D
Positive
common
dedicated
AJ65SBTCF1-32T (Note 3)
AJ65BTC1-32T
(Note 3)
3-wire type
Screw terminal block
1-wire type
LED
Spring clamp terminal block
Distributed 16-point
1-wire type
Screw terminal block
1-wire type
LED
Spring clamp terminal block
1-wire type
3-wire type
Conversion module model
FA-TB16XY1, 2
FA-TB32XY
FA-TBS32XY
FA-TB32XYL
FA-TE32XY
FA-TB16XY1, 2
FA-TB32XY
FA-TBS32XY
FA-TB32XYL
FA-TE32XY
(Note 1)
(Note 2)
(Note 1)
(Note 2)
Connection cable
1-13
1-11
1-12
1-12
1-15
1-13
1-11
1-12
1-12
1-15
FA-CBL**FMH
1-20
FA-CBL**FMH
1-20
Note 1: For a module-to-module cable, use FA-CBL**MMH. Use the same power supply for the modules.
Note 2: For use with 24VDC only.
Note 3: When used with 12VDC, connect the 12VDC to a 24VDC terminal.
Mitsubishi Electric CC-Link Remote I/O Selection Chart 2
Remote I/O ↔ Conversion Module + Conversion Module
● Connection example: Remote I/O module ↔ Screw terminal block
AJ65SBTCF1-32T + FA-CBL10FM2H + FA-TB16XY + FA-TB16XY
FA-TB16XY
FA-TB16XY
Input/
Output
Input
Output
Programmable controller
module model
AJ65SBTCF1-32D
AJ65BTC1-32D
AJ65SBTCF1-32T
AJ65BTC1-32T
Positive common
dedicated
(Note 2)
(Note 2)
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2H
(Note 1)
1-21
Screw terminal block
1-wire type
FA-TB16XY
1-11
FA-TB16XY
1-11
FA-CBL**FM2H
(Note 1)
1-21
Note 1: For two connected modules, use the same power supply.
Note 2: When used with 12VDC, connect the 12VDC to a 24VDC terminal.
Mitsubishi Electric CC-Link Remote I/O Selection Chart 3
Remote I/O ↔ Conversion Module + Interface Module
● Connection example: Remote I/O module ↔ Conversion module + Interface module
AJ65SBTCF1-32T + FA-CBL10FM2H + FA-TB16XY + FA-TH16YRA20S
FA-TB16XY
FA-TH16YRA20S
Input/
Output
Input
Output
Programmable controller
module model
AJ65SBTCF1-32D Positive common
AJ65BTC1-32D
dedicated
AJ65SBTCF1-32T (Note 2)
AJ65BTC1-32T
(Note 2)
Conversion module type
Screw terminal block
Screw terminal block
1-wire type
1-wire type
Conversion module model
FA-TB16XY
FA-TB16XY
Interface module model
Connection cable
1-11
FA-TH16XRA20S
2-13
FA-CBL**FM2H
(Note 1)
1-21
1-11
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2H
(Note 1)
1-21
Note 1: For two connected modules, use the same power supply.
Note 2: For use with 24VDC only.
1-10
1. Conversion Module for DC I/O (Connector ↔ Screw Terminal Block)
Individual Specifications
MELSEC-dedicated 16-point 1-wire type
Features
1
This module is a MELSEC-dedicated 16-point connector terminal block type conversion module. The module branches the 32 points
of a MELSEC connector-type I/O module into 16-point units using a branch cable, allowing separate use from other 16-point modules.
The + screw of the terminal is a spring-up screw, making round solderless terminal installation easy.
The Mitsubishi programmable controller input and output signal (0-F) numbers are indicated on the marking strip, making
wiring easy.
The module can be installed using a DIN rail or screws.
Related Materials
Applicable Standards
General Specifications
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
7-1
Specifications
Specifications
FA-TB16XY
85 (3.35)
75 (2.96)
24VDC
Precautions
●
●
●
●
7.62 (0.30)
35 (1.38)
11 (0.44)
40 (1.58)
Applicable wire,
0.3 to 2mm2 (with solderless terminal use), 58.8 to 88.2N cm (5.21 to 7.81lbf in)
tightening torque
Screw installation M4 × 0.7mm × 12mm or more, tightening torque: 78 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
DIN rail
500VAC for 1 minute, 10MΩ or more
(between all DC external terminals↔ground, between charged areas)
Approx. 130g
●X and Y of the input/output device signal is X when the connected I/O module is an input module,
and Y when the connected I/O module is an output module. The number is determined by the slot
where the I/O module is inserted.
●Failure to push in the module connector until it is locked may cause poor contact.
46.5 (1.84)
5 (0.20)
Terminal screw
Withstand voltage,
insulation resistance
Weight
20
16 points / 1 (24V) common point + 1 (0V) common point
M3 screws, number of terminals: 18P, 7.62-mm (0.3-inch) pitch,
spring-up screw with finger protection cover
k
loc
ple )
Sim 120°
(
2
28.8VDC, 1A (each signal terminal), 2A (each power supply terminal)
7 (0.28)
5 (0.20)
2.5 (0.10)
Unit: mm (inch)
2-Φ4.5 installation holes
16 points, X0 to XF or Y0 to YF
Module installation
cUL
External Dimension
Item
Model
No. of I/O points
I/O device numbers
Rated voltage
Maximum operating
voltage, current
Common method
Terminal block
UL
2.5 (0.10)
Conversion Module
For DC I/O
FA-TB16XY
Marking strip
DC DC
24V 0V
0 1 2 3 4 5 6 7 8 9 A B C D E F
Wiring Diagram
1
2
3
4
20
18
16
14
12
10
8
6
19
17
15
13
11
9
7
5
CON1
(20P)
1A
2A
DC24V
DC0V
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
TB1
(18P)
MELSEC-dedicated 32-point 1-wire type
FA-TB32XY
Features
This 32-point terminal block type conversion module is used with a 40-core cable for 32 points of the MELSEC
connector-type I/O module.
The + screw of the terminal is a spring-up screw, making round solderless terminal installation easy.
The Mitsubishi programmable controller input and output signal (0-1F) numbers are indicated on the marking strip, making
wiring easy.
The module can be installed using a DIN rail or screws.
Related Materials
Applicable Standards
General Specifications
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
7-1
Specifications
Specifications
FA-TB32XY
Precautions
●
●
Model Selection MELSEC-Q
1-5
1-6
0 1
NC
18
19
1A
1B
1C
1D
1E
1F
24V
0V
16
MELSEC-L
1-7
MELSEC-AnS
1-8
35 (1.38)
2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 24V 0V
17
14
15
12
13
11
E
10
F
C
D
B
8
A
9
6
7
4
5
3
2
2A
42.5 (1.68)
Marking strip
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
B2
B1
B4
B3
A4
A2
A1
A3
1A
lock
ple
Sim 20°)
(1
12 (0.48)
40 (1.58)
7.62 (0.30)
1-9
CC-Link
1-10
2.5 (0.10)
●
●
Wiring Diagram
0
7 (0.28)
B20
5 (0.20)
32 points / 1 (24V) common point + 1 (0V) common point
M3 screws, number of terminals: 34P, 7.62-mm (0.3-inch) pitch,
spring-up screw with finger protection cover
Applicable wire,
0.3 to 2mm2 (with solderless terminal use), 58.8 to 88.2N cm (5.21 to 7.81lbf in)
tightening torque
Screw installation M4 × 0.7mm × 12mm or more, tightening torque: 78 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
DIN rail
500VAC for 1 minute, 10MΩ or more
(between all DC external terminals↔ground, between charged areas)
Approx. 160g
●X and Y of the input/output device signal is X when the connected I/O module is an input module,
and Y when the connected I/O module is an output module. The number is determined by the slot
where the I/O module is inserted.
●Failure to push in the module connector until it is locked may cause poor contact.
Withstand voltage,
insulation resistance
Weight
B1
28 (1.11)
28.8VDC, 1A (each signal terminal), 2A (each power supply terminal)
Module installation
1
4.5 (0.18)
24VDC
Terminal block
1-11
156 (6.15)
147 (5.79)
2.5 (0.10)
Unit: mm (inch)
2-Φ4.5 installation holes
32 points, X0 to X1F or Y0 to Y1F
Terminal screw
TB1
(34P)
cUL
External Dimension
Item
Model
No. of I/O points
I/O device numbers
Rated voltage
Maximum operating
voltage, current
Common method
CON1
(40P)
UL
1. Conversion Module for DC I/O (Connector ↔ Screw Terminal Block)
Individual Specifications
Features
This 32-point terminal block type conversion module is used with a 40-core cable for 32 points of the MELSEC connector-type I/O module.
The terminal block is a small-size type that employs M3 7-mm (0.28-inch) pitch screws.
The module prevents screws from falling by employing a screw fall-prevention mechanism, and offers easy installation of
round solderless terminals by employing a screw holding mechanism.
The terminal screws include a black screw every five terminals, making verification of terminal locations easy.
The frames of the terminal block marking strip include a bold line every four upper/lower level points, making verification of
terminal number locations easy.
The terminal numbers are the same as the MELSEC signal numbers, preventing wiring errors.
The module can be installed using a DIN rail or screws.
Related Materials
Applicable Standards
General Specifications
M3 7-mm (0.28-inch) Applicable Solderless Terminal
7-1
Specifications
Specifications
FA-TBS32XY
●
7.0 (0.28)
Marking strip
0 1
2.5 (0.10)
35 (1.38)
Sim
●
●
5 (0.20)
●
lock
ple )
0°
(12
4.5 (0.18)
12 (0.48)
40 (1.58)
Applicable wire,
0.3 to 1.25mm2 (with solderless terminal use), 43 to 58N cm (3.82 to 5.12lbf in)
tightening torque
Screw installation M4 × 0.7mm × 25mm or more, tightening torque: 78 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
DIN rail
500VAC for 1 minute, 10MΩ or more
(between all DC external terminals↔ground, between charged areas)
Approx. 150g
●X and Y of the input/output device signal is X when the connected I/O module is an input module,
and Y when the connected I/O module is an output module. The number is determined by the slot
where the I/O module is inserted.
●Failure to push in the module connector until it is locked may cause poor contact.
Precautions
B20
32 points / 1 (24V) common point + 1 (0V) common point
M3 screws, number of terminals: 34P, 7-mm (0.28-inch) pitch,
with screw holding and fall-prevention mechanism
2.5 (0.10)
B1
28.8VDC, 1A (each signal terminal), 2A (each power supply terminal)
Terminal screw
21 (0.83)
4.5 (0.18)
Φ4.5 installation holes
24VDC
Withstand voltage,
insulation resistance
Weight
cUL
Unit: mm (inch)
127 (5.00)
118 (4.65)
32 points, X0 to X1F or Y0 to Y1F
Module installation
UL
7-2
External Dimension
Item
Model
No. of I/O points
I/O device numbers
Rated voltage
Maximum operating
voltage, current
Common method
Terminal block
1
FA-TBS32XY
Conversion Module
For DC I/O
MELSEC-dedicated 32-point 1-wire small-size type
47.8 (1.89)
2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 24V 0V
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
B2
B1
B4
B3
A4
A2
A1
A3
Wiring Diagram
NC
Connector
1A
1D
1E
1F
24V
0V
1A
1C
1B
18
19
16
17
14
15
12
11
F
13
E
10
C
D
B
8
A
9
6
7
4
5
3
1
2
0
2A
Terminal block
MELSEC-dedicated 32-point 1-wire type with display
FA-TB32XYL, FA-TB32XYH
Features
This 32-point terminal block type conversion module is used with a 40-core cable for 32 points of the MELSEC connector-type I/O module.
This module displays the operating status of the power supply and signals. FA-TB32XYL can be used for positive common
input and sink output and FA-TB32XYH can be used for negative input and source output.
The + screw of the terminal is a spring-up screw, making round solderless terminal installation easy.
The Mitsubishi programmable controller input and output signal (0-1F) numbers are indicated on marking strip, making wiring easy.
The module can be installed using a DIN rail or screws.
Related Materials
General Specifications
Applicable Standards
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
7-1
Specifications
Precautions
7.62 (0.30)
Marking strip
35.5 (1.40)
0°)
41.5 (1.64)
8.5 (0.34)
●
●
Sim
●
●
5 (0.20)
Withstand voltage,
insulation resistance
Weight
S n Type L w i e comm n)
(12
FA TB 2XYL
Display
Applicable wire,
0.3 to 2mm2 (with solderless terminal use), 58.8 to 88.2N cm (5.21 to 7.81lbf in)
tightening torque
Screw installation M4 × 0.7mm × 20mm or more, tightening torque: 78 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
DIN rail
500VAC for 1 minute, 10MΩ or more
(between all DC external terminals↔ground, between charged areas)
Approx. 200g
●X and Y of the input/output device signal is X when the connected I/O module is an input module,
and Y when the connected I/O module is an output module. The number is determined by the slot
where the I/O module is inserted.
●Failure to push in the module connector until it is locked may cause poor contact.
Module installation
16 (0.63)
50 (1.97)
0 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F PW
32 points / 1 (24V) common point + 1 (0V) common point
M3 screws, number of terminals: 34P, 7.62-mm (0.3-inch) pitch,
spring-up screw with finger protection cover
Terminal screw
15 (0.60)
B20
k
oc
B1
5 (0.20)
2-Φ4.5 installation holes
6 (0.24)
Unit: mm (inch)
148 (5.83)
138 (5.44)
19.2 to 28.8VDC, 1A (each signal terminal), 2A (each power supply terminal)
Terminal block
cUL
External Dimension
Specifications
FA-TB32XYL, FA-TB32XYH
32 points, X0 to X1F or Y0 to Y1F
(with power supply and signal 0 to 1F display; display current consumption: 4mA/point at 24VDC)
24VDC
l
ple
Item
Model
No. of I/O points
I/O device numbers
Rated voltage
Maximum operating
voltage, current
Common method
UL
0 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 24V 0V
Wiring Diagram
Model Selection MELSEC-Q
1-5
1-6
1-7
MELSEC-AnS
1E
1F
24V
0V
1D
1C
1A
1-8
1B
18
19
16
17
14
15
12
13
11
E
10
F
C
MELSEC-L
D
B
8
A
9
7
6
5
3
4
2A
2
TB1
(34P)
NC
1A
0
1F
24V
0V
1E
1D
1A
1C
1B
18
19
16
17
14
15
13
12
10
11
F
E
C
D
A
B
9
8
6
7
4
5
3
2
0
1
TB1
(34P)
2A
CON1
(40P)
1
1A
NC
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
B2
B1
B4
B3
A4
A2
A1
A3
CON1
(40P)
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
B2
B1
B4
B3
A4
A2
A1
A3
[FA-TB32XYH]
[FA-TB32XYL]
1-9
CC-Link
1-10
1-12
1. Conversion Module for DC I/O (Connector ↔ Screw Terminal Block)
Individual Specifications
MELSEC-dedicated distributed 16-point 3-wire type
Conversion Module
For DC I/O
FA-TB16XY1, FA-TB16XY2
Features
1
This conversion module, with a cable, is used to distribute 32 points of the MELSEC connector-type I/O module into
16-point modules.
The module has a 24V or 0V common terminal per two signal points, making wiring with other distributed type modules
possible.
The + screw of the terminal is a spring-up screw, making round solderless terminal installation easy.
The Mitsubishi programmable controller input and output signal (0 to F, 10 to 1F) numbers are indicated on the marking
strip, making wiring easy.
The module can be installed using a DIN rail or screws.
Related Materials
General Specifications
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
7-1
Applicable Standards
Related Products
UL
Connector Covers 1-14
cUL
Specifications
External Dimension
Specifications
Unit: mm(inch)
FA-TB16XY2
16 points, X0 to XF or Y0 to YF
2-Φ4.5 installation holes
148 (5.83)
138 (5.44)
16 points, X10 to 1XF or Y10 to Y1F
15 (0.60)
5 (0.20)
24VDC
16 points / 8 (24V) common points + 8 (0V) common points
M3 screws, number of terminals: 34P, 7.62-mm (0.3-inch) pitch,
spring-up screw with finger protection cover
0.3 to 2mm2 (with solderless terminal use),
Applicable wire,
58.8 to 88.2N cm (5.21 to 7.81lbf in)
tightening torque
M4 × 0.7mm × 20mm or more,
Screw installation
tightening torque: 78 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
DIN rail
500VAC for 1 minute, 10MΩ or more
(between all DC external terminals↔ground, between charged areas)
Approx. 180g
●X and Y of the input/output device signal is X when the connected I/O module is an input module,
and Y when the connected I/O module is an output module. The number is determined by the slot
where the I/O module is inserted.
●Failure to push in the module connector until it is locked may cause poor contact.
Terminal screw
●
Module installation
●
●
Withstand voltage,
insulation resistance
Weight
Precautions
7.62 (0.30)
5 (0.20)
Terminal block
●
35.5 (1.40)
16 (0.63)
50 (1.97)
28.8VDC, 1A (each signal terminal), 2A (each power supply terminal)
B20
k
loc
ple
Sim 20°)
(1
B1
6 (0.24)
FA-TB16XY1
41.5 (1.64)
8.5 (0.34)
Item
Model
No. of I/O points
I/O device numbers
Rated voltage
Maximum operating
voltage, current
Common method
Marking strip FA-TB16XY1
0 0V 1 24V 2 0V 3 4V 4 0V 5 4V 6 0V 7 4V 8 0V 9 24V A 0V B 4V C 0V D 24V E 0V F 4V 4V 0V
Marking strip FA-TB16XY2
10 0V 11 24V 12 0V 13 4V 14 0V 15 24V 16 0V 17 4V 18 0V 19 24V 1A 0V 1B 4V 1C 0V 1D 24V 1E 0V 1F 4V 24V 0V
Wiring Diagram
FA-CBL***FMV
X40 to X4F
SW
SW SW ………
24VDC
Model Selection MELSEC-Q
1-5
1-6
A15
A14
A13
A12
A11
A10
A9
A8
A7
A15
A14
A13
A12
A11
A10
A9
A8
A7
0V
1F
24V
24V
0V
………
Y20 to Y27
24VDC
Y30 to Y3F
24VDC 2-wire type source output
MELSEC-L
1-7
MELSEC-AnS
1-8
1-9
CC-Link
1-10
24V
24V
0V
1F
1E
0V
24V
1D
0V
1C
24V
1B
0V
1A
24V
19
0V
18
24V
17
0V
16
24V
15
0V
10
0V
11
24V
+
Connector cover
FA-CAP40MIL10
SW
X50 to X5F
24VDC 3-wire type sensor input
(Positive common input)
1-13
FA-TB16XY2
…
SW SW
FA-TB16XY1
0V
F
24V
24V
0V
0
0V
1
24V
0V
1F
24V
24V
0V
10
0V
11
24V
0V
F
24V
24V
0V
0
0V
1
24V
Connector cover
FA-CAP40MIL10
+
………
Other
pins
A16
A16
14
24V
FA-*CBL**MMH
FA-TB16XY2
Other
pins
A17
A17
13
0V
FA-CBL***DMFY
FA-*CBL**MMH
FA-TB16XY1
A6
A18
A18
12
24V
QY81P
QX41
Power supply
Distributed type Connector ↔ Screw terminal block conversion module
CPU
A5
B2
B1
B4
B3
A4
A2
A1
A19
A19
11
2A
10
24V
24V
0V
F
0V
E
24V
D
0V
C
24V
B
0V
24V
A
9
0V
8
24V
7
0V
6
24V
5
0V
4
24V
3
0V
2
24V
1
0
0V
TB1
(34P)
Example of use
(MELSEC-Q series)
A6
A20
A20
1A
2A
TB1
(34P)
A5
B2
B1
B4
B3
A4
A2
A1
Other
pins
CON2
(40P)
0V
1A
CON1
(40P)
Other
pins
B6
B7
B5
B2
B1
B4
B3
A4
A2
A1
B5
B2
B1
B4
B3
A4
A2
A1
B6
B8
B7
B9
B9
B8
B10
B11
B10
B12
B11
B14
B13
B12
B13
B15
B14
B17
B18
B16
B15
B16
B17
B18
B19
[FA-TB16XY2]
B19
CON2
(40P)
B20
CON1
(40P)
B20
[FA-TB16XY1]
1. Conversion Module for DC I/O(Connector ↔ Screw Terminal Block)
Individual Specifications
Features
This 40P screw terminal block (regular screws) type conversion module is used to convert signals from a general-purpose
connector-type module of MELSEC programmable controller.
The module is a small-size type that employs M3 7-mm (0.28-inch) pitch screws in the terminal block.
One signal point is connected to one terminal point; the module is applicable as a 40-point general-purpose connector /
terminal block conversion module.
The module prevents screws from falling by employing a screw fall-prevention mechanism, and offers easy installation of
round solderless terminals by employing a screw holding mechanism.
The terminal screws include a black screw every five terminals, making verification of terminal locations easy.
The module can be installed using a DIN rail or screws.
Related Materials
Applicable Standards
General Specifications
M3 7-mm (0.28-inch) Applicable Solderless Terminal
7-1
Specifications
0.3 to 1.25mm2, 43 to 58Nc m (3.82 to 5.12lbf in)
●
●
7.0 (0.28)
●
Marking strip
1 2
35 (1.38)
47.8 (1.89)
5 (0.20)
●
3 4 5 6 7 8 9
21 (0.83)
°)
(120
4.5 (0.18)
12 (0.48)
40 (1.58)
−
M3 screws, number of terminals: 40P, 7-mm (0.28-inch) pitch,
with screw holding and fall prevention mechanisms
M4 × 0.7mm × 25mm or more,
Screw installation
tightening torque: 78.8 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
DIN rail
500VAC for 1 minute, 10MΩ or more
(between all DC external terminals↔ground)
Approx. 190g
Failure to push in the module connector until it is locked may cause poor contact.
ock
le l
p
Sim
2.5 (0.10)
4.5 (0.18)
40
2.5 (0.10)
148 (5.83)
139 (5.48)
2
Applicable wire,
tightening torque
Withstand voltage,
insulation resistance
Weight
Precautions
cUL
Unit: mm(inch)
Φ4.5 installation holes
48VDC, 1A/point
Terminal screw
Module installation
UL
7-2
External Dimension
Specifications
FA-TBS40P
40 points, general-purpose
Item
Model
No. of points
Maximum operating
voltage, current
Common method
Terminal block
1
FA-TBS40P
Conversion Module
For DC I/O
General-purpose 40-point small-size type
0 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
CON1
(40P)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Wiring Diagram
39
40
37
38
35
36
33
34
31
32
29
30
27
28
25
26
23
24
21
22
19
20
17
18
15
16
13
12
14
9
11
10
7
8
5
6
3
4
2
TB1
(40P)
1
1A
Example of use
FA-CBL***FMV-M
FA-CBL***FMV-M
………
………
1
2
+ 24VDC
………
X0 to XF
X10 to X1F
24VDC 1-wire type limit SW, pushbutton switch input
(Positive common input)
36
37
38
39
40
FA-TBS40P
36
37
38
39
40
16
17
18
19
20
21
2
1
FA-TBS40P
16
17
18
19
20
21
QX41
CPU
QY41P
(MELSEC-Q series)
Power supply
General-purpose connector-type I/O module ↔ Screw terminal block conversion module
24VDC
………
+
Y20 to Y2F
Y30 to Y3F
24VDC 1-wire type lamp output
(0.1A or less, sink output)
MIL40P connector covers
FA-CAP40MIL10
Features
When distributed-type modules are distributed using cables, the last module connector is open,
resulting in the possibility of dust contamination. The connector cover is used to prevent
contamination by such dust and the like.
Specifications
Item
Model
Applicable module
Weight
Specifications
FA-CA40MIL10
(protective cover for preventing contamination of an unused connector by foreign matter; includes 10 covers)
FA-TB16XY1, FA-TB16XY2
Approx. 30g
Model Selection MELSEC-Q
1-5
1-6
MELSEC-L
1-7
MELSEC-AnS
1-8
1-9
CC-Link
1-10
1-14
1. Conversion Module for DC I/O (Connector ↔ Spring Clamp Terminal Block) Individual Specifications
MELSEC-dedicated 32-point 1-wire type
Features
1
This 32-point spring clamp terminal block type conversion module is used with a 40-core cable for 32 points of the
MELSEC connector-type I/O module.
The spring clamp terminal can be connected to a wire by pressing and releasing the unlock button using a
general-purpose Phillips or flathead screwdriver.
Screw tightening is not required, eliminating errors such as failure to tighten screws due to forgetfulness or loose screws
due to vibration and eliminating the need to further tighten screws during periodic inspections.
The module provides a tester rod insertion hole, making it possible to conduct checks using a tester, and is provided with
a cover that prevents contamination by foreign matter as well as a wire peeling dimension gauge.
The Mitsubishi programmable controller input and output signal (0 to 1F) numbers are indicated on the marking strip,
making wiring easy.
The module can be installed using a DIN rail or screws, and the horizontal width is small in size at approximately
two-thirds the screw-type.
Related Products
Related Materials
General Specifications
Applicable Solderless Terminal
7-1
Specifications
External Dimension
Specifications
FA-TE32XY
32 points, X0 to X1F or Y0 to Y1F,
common method: 32 points / 2 (24V) common points + 2 (0V) common points
24VDC
103 (4.06)
93 (3.67)
5.08 (0.20)
M4 × 0.7mm × 25mm or more, tightening torque: 78 to 118N cm (6.95 to 10.41lbf in)
●
●
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
500VAC for 1 minute, 10MΩ or more
(between all DC external terminals↔ground, between charged areas)
Approx. 105g
●X and Y of the input/output device signal is X when the connected I/O module is an input module,
and Y when the connected I/O module is an output module. The number is determined by the slot
where the I/O module is inserted.
●Failure to push in the module connector until it is locked may cause poor contact.
Precautions
Marking strip
0
2
1
4
3
6
5
1A
1D
1E
1F
24V
24V
0V
0V
1A
1C
1B
18
19
16
17
14
15
12
11
13
E
F
10
C
D
B
8
A
9
6
7
4
5
3
2
0
2A
1
TB1
(36P)
NC
CON1
(40P)
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
B2
B1
B4
B3
A4
A2
A1
A3
Wiring Diagram
Example of use
QX41
CPU
QY41P
(MELSEC-Q series)
Power supply
Spring clamp terminal block type conversion module
FA-CBL***FMV
FA-CBL***FMV
……… ……… ……… ……
+
………
24VDC
X0 to X1F
Model Selection MELSEC-Q
24VDC
Y20 to Y3F
24VDC 1-wire type limit SW, push-button SW input
(Positive common input)
1-15
1E
1F
24V
24V
0V
0V
0
1
1
0
1E
1F
24V
24V
0V
0V
FA-TE32XY
+
FA-TE32XY
1-5
1-6
MELSEC-L
24VDC 1-wire type lamp output
(0.1A or less, sink output)
1-7
MELSEC-AnS
1-8
1-9
CC-Link
1-10
8
7
A
9
C
B
10 12 14 16 18 1A 1C 1E 24V 0V
E
D
F
11 13 15
17 19 1B 1D 1F 24V 0V
35 (1.38)
45.75 (1.81)
4.5 (0.18)
Applicable
wire
Screw
installation
DIN rail
Withstand voltage,
insulation resistance
Weight
B20
44 (1.74)
Terminal
screw
Module installation
B1
Recommended tool: Phillips screwdriver (shaft diameter: Φ6, H-type no. 2),
flathead screwdriver (shaft diameter: Φ3, round end width: 2.6)
No. of terminals: 36P, 5.08-mm (0.2-inch) pitch, no. of wire insertions: 1/insertion port
Maximum no. of wire insertions/removals: 50,
applicable solderless terminals: FA-VTC125T9, FA-VTCW135T9
Stranded wire: 0.2 to 1.25mm2, AWG24-AWG16 (wire diameter: Φ0.18 or more)
Single wire: Φ0.4 to 1.2mm, AWG26 to AWG16, coating strip length: 8 to 9
k
loc
ple )
Sim 120°
(
28.8VDC, 1A (each signal terminal), 2A (each power supply terminal)
43.3 (1.71)
20 (0.79)
4.5 (0.18)
Unit: mm(inch)
2-Φ4.5 installation holes
13 (0.52)
Item
Model
No. of I/O points
I/O device numbers
Rated voltage
Maximum operating
voltage, current
Terminal block
7-2
5.5 (0.22)
Conversion Module
For DC I/O
FA-TE32XY
1. Conversion Module for DC I/O (Connector ↔ Spring Clamp Terminal Block) Individual Specifications
Connector to controller
2
40
Panel installation
screw hole
Tester rod insertion hole
for conduction verification
Wire stripping length gauge
9 mm (0.36 inch)
Wire lock/unlock button
1
Marking strip cover,
marking strip
• The inner spring opens by
pressing the button using a
Phillips or flathead
screwdriver, allowing you to
lock or unlock the wire.
Conversion Module
For DC I/O
Description of each area
DIN rail
installation hook
Wire stripping length gauge
9 mm (0.36 inch)
Wire insertion port
(Note 1)
Spring clamp terminal block
Wire insertion direction
Note 1: Make sure there is one wire per insertion port.
Description of spring clamp
1) Initial state
2) Press button with driver
3) Insert wire with button pressed
4) Remove driver: Connection complete
Driver
Button
Leaf spring
Wire insertion
port
Wire
Wire installation method
Connect and disconnect the wire by pressing the button using a driver.
Wire peeling dimension chart
Wire installation terminal processing mode
Wire stripping length
When the stripped wire is inserted straight
8 to 9mm (0.32 to 0.36 inch)
Recommended solderless terminals
NICHIFU Bar Solderless Terminals
Product number: TGV TC-1.25-9T (for 1 wire), applicable tool: NH65
Product number: TGWV TC-1.25-9T (for 2 wires), applicable tool: NH66
Contact
NICHIFU SINGAPORE PTE.LTD.
3 Shenton Way #21-09, Shenton House, Singapore 068805
Tel: +65-6741 3008 Fax: +65-6741 3605
E-mail: singapore@nichifu.co.jp
NICHIFU AMERICA, INC.
22 Congress Circle West, Roselle‚ IL 60172 U.S.A
Tel: +1-630-351-1958 Fax: +1-630-351-1961
E-mail: america@nichifu.com
NICHIFU EUROPE B.V.
Frans Coenenhove 9, 3438 HJ, Nieuwegein, The Netherlands
Tel: +31-30 268 18 86 Fax: +31-30 268 18 87
E-mail: europe@nichifu.co.jp
MORIS CO., LTD.
1-3-58‚ Tsurumi‚ Tsurumi-Ku‚ Osaka‚ Japan 538-0053
Tel: +81-6-6911-1455 Fax: +81-6-6911-1477
E-mail: moris@nichifu.co.jp
Model Selection MELSEC-Q
1-5
1-6
MELSEC-L
1-7
MELSEC-AnS
1-8
1-9
CC-Link
1-10
1-16
1. Conversion Module for DC I/O (Discrete Cable & Module-to-Module Cable)
Individual Specifications
Discrete cable (40-core cables)
Conversion Module
For DC I/O
FA-CBL**FV
(FCN 40P type)
Specifications
FCN367J040-AU/MW: Fujitsu Component
−
1
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Features
Cable jacket
This round 40-core cable vertically comes out
from the connector-type I/O module of
programmable controllers of other companies.
The cable comes out vertically from the FCN
40P connector to prevent poor contact,
cutting, etc. due to the tension applied to the
upper end of the core wire.
Twisted pair wire
Insulator
Structure diagram
Conductor
Insulator
Conductor
External Dimension
Related Materials
General Specifications
Model
Specifications
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Core Wire Identification Diagram
Example: B17
Programmable controller side
Cable length
View
Core wire : Dark gray
Dot color : Black
No. of dots : 4
7-1
Core wire color
CON1
A20
A1
B20
B1
Dot color
No. of dots
For MELSEC positive common input/sink output
Cable length
2m (78.75 inch)
3m (118.12 inch)
5m (196.86 inch)
FA-CBL20FV
FA-CBL30FV
FA-CBL50FV
Weight
Approx. 270g
Approx. 390g
Approx. 610g
Wiring Diagram
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
Discrete cable core wire identification
Discrete cable Core wire color Dot color No. of dots
Pink
Black
4
Pink
Red
4
Yellow
Black
4
Yellow
Red
4
White
Black
4
White
Red
4
gray
Black
4
gray
Red
4
Orange
Black
4
Orange
Red
4
Pink
Black
3
Pink
Red
3
Yellow
Black
3
Yellow
Red
3
White
Black
3
White
Red
3
gray
Black
3
gray
Red
3
Orange
Black
3
Orange
Red
3
Pink
Black
2
Pink
Red
2
Yellow
Black
2
Yellow
Red
2
White
Black
2
White
Red
2
gray
Black
2
gray
Red
2
Orange
Black
2
Orange
Red
2
Pink
Black
1
Pink
Red
1
Yellow
Black
1
Yellow
Red
1
White
Black
1
White
Red
1
gray
Black
1
gray
Red
1
Orange
Black
1
Orange
Red
1
(for FCN 40P↔MIL 40P)
FA-CBL**FMV
Specifications
Item
Features
This cable is used to connect a MELSEC-Q/AnS
series FCN 40P connector-type I/O module
and a MELSEC-dedicated 32-point conversion
module.
This round 40-core cable connects the FCN
40P
(vertical)
connector
of
the
MELSEC-Q/AnS series connector-type I/O
module and the MIL 40P connector of the
other module. The cable vertically comes out
from the FCN 40P connector.
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Twisted pair wire
Insulator
Conductor
Insulator
Conductor
External Dimension
Programmable controller side
View
This
cable
cannot
be
used
with
general-purpose 40P conversion modules.
Cable length
View
CON1
Related Materials
1-17
D7940-7500SC, D3448-7940: Sumitomo 3M
Structure diagram
CON2
A20
A1
B20
A20
B20
B1
B1
A1
7-1
Model Selection MELSEC-Q
Cable length
Model
FCN367J040-AU/MW: Fujitsu Component
Cable jacket
The cable comes out vertically from the FCN
40P connector to prevent poor contact,
cutting, etc. due to the tension applied to the
upper end of the core wire.
General Specifications
Specifications
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
FA-CBL10FMV
FA-CBL20FMV
FA-CBL30FMV
FA-CBL50FMV
1m (39.38 inch)
2m (78.75 inch)
3m (118.12 inch)
5m (196.86 inch)
Weight
Approx. 160g
Approx. 270g
Approx. 390g
Approx. 590g
Wiring Diagram
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
CON2
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
Note 1: Connectable to source output modules QY82P and
A1SY82.
1-5
1-6
MELSEC-L
1-7
MELSEC-AnS
1-8
1-9
CC-Link
1-10
1. Conversion Module for DC I/O (Module-to-Module Cable)
For MELSEC positive common input / sink output
Individual Specifications
Specifications
Features
This round 40-core cable comes out from the
MELSEC-Q/AnS
series
FCN
40P
connector-type I/O module and branches at
the other end of the cable into two MIL 20P
connectors,
each
connecting
to
a
MELSEC-dedicated 16-point conversion
module.
The cable comes out vertically from the FCN
40P connector to prevent poor contact,
cutting, etc. due to the tension applied to the
upper end of the core wire.
The
cable
cannot
be
used
with
general-purpose 20P conversion modules.
FCN367J040-AU/MW: Fujitsu Component
D7920-B500FL, D3448-7920: Sumitomo 3M × 2
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
Conductor
Insulator
Conductor
External Dimension
Unit: mm (inch)
Cable length
150 (5.91)
A
View
7-1
CON1
B20
B
A1
20
Vie
w
A20
Weight
1m (39.38 inch)
Approx. 160g
2m (78.75 inch)
Approx. 270g
3m (118.12 inch)
Approx. 380g
5m (196.86 inch)
Approx. 600g
Wiring Diagram
Insulator
Programmable controller side
Cable length
Twisted pair wire
Structure diagram
Related Materials
General Specifications
Model
FA-CBL10FM2V
FA-CBL20FM2V
FA-CBL30FM2V
FA-CBL50FM2V
Specifications
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
1
FA-CBL**FM2V
Conversion Module
For DC I/O
(FCN 40P↔MIL 20P × 2, MIL 20P side branching type)
B1
2
19
1
Note 1: A of the 20P connector corresponds to inputs X0 to XF / outputs Y0 to YF, and B
of the 20P connector corresponds to inputs X10 to X1F / outputs Y10 to Y1F.
For MELSEC negative common input
CON1
MIL 20P
Connector A
CON1
MIL 20P
Connector B
B1
2
B2
2
A1
4
A2
4
B3
1
A3
1
B4
3
A4
3
B5
5
A5
5
B6
7
A6
7
B7
9
A7
9
B8
11
A8
11
B9
13
A9
13
B10
15
A10
15
B11
17
A11
17
B12
19
A12
19
B13
6
A13
6
B14
8
A14
8
B15
10
A15
10
B16
12
A16
12
B17
14
A17
14
B18
16
A18
16
B19
18
A19
18
B20
20
A20
20
(for FCN 40P↔MIL 40P)
FA-CBL**FMVE
Specifications
Specifications
Item
Programmable controller-side
connector
Converter module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Features
This cable is used to connect a
MELSEC-Q/AnS series FCN 40P connector-type
negative common input module and a
MELSEC-dedicated 32-point conversion
module.
The cable comes out vertically from the FCN
40P connector to prevent poor contact,
cutting, etc. due to the tension applied to the
upper end of the core wire.
This
cable
cannot
be
used
with
general-purpose 40P conversion modules.
D7940-7500SC, D3448-7940: Sumitomo 3M
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
Conductor
Insulator
Conductor
External Dimension
Cable length
View
7-1
CON1
View
CON2
A20
A1
B20
A20
B20
B1
B1
A1
Model Selection MELSEC-Q
1-5
1-6
MELSEC-L
1m (39.38 inch)
2m (78.75 inch)
3m (118.12 inch)
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
Insulator
Programmable controller side
Cable length
Weight
Approx. 140g
Approx. 270g
Approx. 400g
Wiring Diagram
Twisted pair wire
Structure diagram
Related Materials
General Specifications
Model
FA-CBL10FMVE
FA-CBL20FMVE
FA-CBL30FMVE
FCN367J040-AU/MW: Fujitsu Component
1-7
MELSEC-AnS
1-8
CON2
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
A2
B2
A1
B1
1-9
CC-Link
1-10
1-18
1. Conversion Module for DC I/O (Module-to-Module Cable)
For MELSEC negative common input
Individual Specifications
(D-Sub 37P↔MIL 40P)
Conversion Module
For DC I/O
FA-CBL**DMFX
Specifications
Specifications
1
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Features
This cable is used to connect a MELSEC-Q/AnS
series D-sub 37P connector-type negative
common
input
module
and
a
MELSEC-dedicated 32-point conversion
module.
1658612-1, 747275-1: Tyco Electronics AMP
D7940-7500SC, D3448-7940: Sumitomo 3M
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
Twisted pair wire
Insulator
Structure diagram
Conductor
The
cable
cannot
be
used
with
general-purpose 40P conversion modules.
Related Materials
General Specifications
Insulator
Conductor
External Dimension
7-1
Programmable controller side
Cable length
View
CON1
View
CON2
20
1
B20
A20
37
19
B1
A1
For MELSEC source output
Model
FA-CBL10DMFX
FA-CBL20DMFX
FA-CBL50DMFX
Cable length
1m (39.38 inch)
2m (78.75 inch)
5m (196.86 inch)
Weight
Approx. 160g
Approx. 270g
Approx. 610g
Wiring Diagram
CON1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NC
NC
NC
NC
NC
CON2
B20
B18
B16
B14
B12
B10
B8
B6
A20
A18
A16
A14
A12
A10
A8
A6
A2
A1
B2
B19
B17
B15
B13
B11
B9
B7
B5
A19
A17
A15
A13
A11
A9
A7
A5
A4
A3
B4
B1
B3
(D-Sub 37P↔MIL 40P)
FA-CBL**DMFY
Specifications
Specifications
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Features
This cable is used to connect a MELSEC-Q/AnS
series D-sub 37P connector source-type
output module and a MELSEC-dedicated
32-point conversion module.
1658612-1, 747275-1: Tyco Electronics AMP
D7940-7500SC, D3448-7940: Sumitomo 3M
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
Twisted pair wire
Insulator
Structure diagram
Conductor
This
cable
cannot
be
used
with
general-purpose 40P conversion modules.
Insulator
Conductor
Related Materials
General Specifications
7-1
External Dimension
Programmable controller side
Cable length
View
View
CON2
CON1
1-19
Model Selection MELSEC-Q
1-5
1-6
MELSEC-L
1-7
MELSEC-AnS
1-8
20
1
B20
A20
37
19
B1
A1
1-9
CC-Link
1-10
Model
FA-CBL10DMFY
FA-CBL20DMFY
FA-CBL50DMFY
Cable length
1m (39.38 inch)
2m (78.75 inch)
5m (196.86 inch)
Wiring Diagram
CON1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NC
NC
NC
NC
CON2
B20
B18
B16
B14
B12
B10
B8
B6
A20
A18
A16
A14
A12
A10
A8
A6
B2
B1
A2
B19
B17
B15
B13
B11
B9
B7
B5
A19
A17
A15
A13
A11
A9
A7
A5
B4
A1
B3
A4
A3
Weight
Approx. 160g
Approx. 270g
Approx. 610g
1. Conversion Module for DC I/O (Module-to-Module Cable)
Individual Specifications
For distributed module connection, general-purpose use
Specifications
Features
D7940-7500SC, D3448-7940: Sumitomo 3M
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
Insulator
Conductor
Related Materials
Insulator
7-1
Conductor
External Dimension
Conversion module 1 side
View
CON1
Conversion module 2 side
Cable length
View
CON2
A1
B1
B20
A20
A20
B20
B1
A1
For Mitsubishi Electric CC-Link remote I/O positive common input / sink output
FA-CBL**FMH
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
Insulator
Conductor
Insulator
Conductor
7-1
External Dimension
Cable length
Programmable controller side
View
CON1
View
CON2
A1
B1
B20
A20
A20
B20
B1
A1
Model Selection MELSEC-Q
1-5
1-6
MELSEC-L
Weight
Approx. 160g
Approx. 280g
Approx. 380g
Wiring Diagram
Twisted pair wire
Structure diagram
Cable length
1m (39.38 inch)
2m (78.75 inch)
3m (118.12 inch)
FA-CBL10FMH
FA-CBL20FMH
FA-CBL30FMH
D7940-7500SC, D3448-7940: Sumitomo 3M
Related Materials
General Specifications
(FCN 40P↔MIL 40P)
Model
Specifications
FCN367J040-AU/MW: Fujitsu Component
Cable jacket
This cable is used to connect a Mitsubishi
Electric CC-Link remote I/O module that
uses an FCN 40P connector and a
MELSEC-dedicated 32-point conversion
module.
CON2
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
Specifications
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Features
Weight
Approx. 90g
Approx. 140g
Approx. 260g
Approx. 590g
Wiring Diagram
Twisted pair wire
Structure diagram
Cable length
0.5m (19.69 inch)
1m (39.38 inch)
2m (78.75 inch)
5m (196.86 inch)
FA-CBL05MMH
FA-CBL10MMH
FA-CBL20MMH
FA-CBL50MMH
D7940-7500SC, D3448-7940: Sumitomo 3M
This round 40-core cable with two MIL 40P
connectors
connects
between
the
distributed-type conversion modules.
General Specifications
Model
Specifications
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
1
FA-CBL**MMH
Conversion Module
For DC I/O
(MIL 40P↔MIL 40P)
1-7
MELSEC-AnS
1-8
CON2
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
1-9
CC-Link
1-10
1-20
1. Conversion Module for DC I/O (Module-to-Module Cable)
Conversion Module
For DC I/O
For Mitsubishi Electric
CC-Link remote I/O positive common input / sink output
Individual Specifications
(FCN 40P↔MIL 20P × 2, MIL 20P-side branching type)
FA-CBL**FM2H
Specifications
1
Features
This round 40-core cable comes out from the
Mitsubishi Electric CC-Link FCN 40P
connector-type I/O module and branches at
the other end of the cable into two MIL 20P
connectors,
each
connecting
to
a
MELSEC-dedicated 16-point conversion
module.
Related Materials
General Specifications
Specifications
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Model
FCN367J040-AU/MW: Fujitsu Component
D7920-B500FL, D3448-7920: Sumitomo 3M × 2
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
MIL20P
Connector B side
B1
2
B2
2
A1
4
A2
4
B3
1
A3
1
B4
3
A4
3
B5
5
A5
5
Insulator
B6
7
A6
7
Conductor
B7
9
A7
9
B8
11
A8
11
Conductor
Unit: mm(inch)
Programmable controller side
Cable length
CON1
Note 1: A of the 20P connector
corresponds to inputs X0
to XF / outputs Y0 to YF,
and B of the 20P
connector corresponds to
inputs X10 to X1F /
B
outputs Y10 to Y1F.
A
A20
B20
Vie
w
B1
w
Vie
A1
20
19
2
1
Wiring Diagram
CON1
Insulator
150 (5.91)
Weight
Approx. 150g
Approx. 270g
Approx. 380g
MIL20P
Connector A side
External Dimension
7-1
1m (39.38 inch)
2m (78.75 inch)
3m (118.12 inch)
CON1
Twisted pair wire
Structure diagram
Cable length
FA-CBL10FM2H
FA-CBL20FM2H
FA-CBL30FM2H
For general-purpose type Mitsubishi Electric programmable controllers
B9
13
A9
13
B10
15
A10
15
B11
17
A11
17
B12
19
A12
19
B13
6
A13
6
B14
8
A14
8
B15
10
A15
10
B16
12
A16
12
B17
14
A17
14
B18
16
A18
16
B19
18
A19
18
B20
20
A20
20
(FCN 40P↔MIL 40P)
FA-CBL**FMV-M
Specifications
Features
This cable is used to connect a Mitsubishi
Electric programmable controller FCN
40Pconnector-type I/O module and a
general-purpose 40P conversion module.
The cable comes out vertically from the FCN
40P connector to prevent poor contact,
cutting, etc. due to the tension applied to the
upper end of the core wire.
The cable cannot be used to connect
MELSEC-dedicated 32-point conversion
modules.
FCN367J040-AU/MW: Fujitsu Component
D7940-7500SC, D3448-7940: Sumitomo 3M
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
Insulator
Conductor
Insulator
Conductor
External Dimension
Cable length
Programmable controller side
View
7-1
CON1
1-21
Twisted pair wire
Structure diagram
Related Materials
General Specifications
Model
Specifications
Item
Programmable controller-side
connector
Conversion module-side
connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Model Selection MELSEC-Q
1-5
1-6
MELSEC-L
1-7
View
A20
A1
B20
B1
MELSEC-AnS
1-8
1-9
CON2
40
(B20)
39
(A20)
(B1)
2
(A1)
1
CC-Link
1-10
FA-CBL10FMV-M
FA-CBL20FMV-M
FA-CBL30FMV-M
Cable length
1m (39.38 inch)
2m (78.75 inch)
3m (118.12 inch)
Wiring Diagram
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
CON2
1 (A1)
2 (B1)
3 (A2)
4 (B2)
5 (A3)
6 (B3)
7 (A4)
8 (B4)
9 (A5)
10 (B5)
11 (A6)
12 (B6)
13 (A7)
14 (B7)
15 (A8)
16 (B8)
17 (A9)
18 (B9)
19 (A10)
20 (B10)
21 (A11)
22 (B11)
23 (A12)
24 (B12)
25 (A13)
26 (B13)
27 (A14)
28 (B14)
29 (A15)
30 (B15)
31 (A16)
32 (B16)
33 (A17)
34 (B17)
35 (A18)
36 (B18)
37 (A19)
38 (B19)
39 (A20)
40 (B20)
Weight
Approx. 160g
Approx. 270g
Approx. 380g
1
Conversion Module
For DC I/O
1. Conversion Module for DC I/O
1-22
2. Interface Module for DC I/O
Conversion Module
For DC I/O
1
Interface Module For DC I/O
2
Conversion Module
For Analog I/O
3
Conversion Module
For High-Speed Counter
4
Cable For
Positioning Module
5
Conversion Module
For MELSEC-L CPU
6
Common Elements
& Appendix
7
2-Contents
Contents
Interface Module Usage Precautions
Overview
Overview
2-1
Precautions When Using a 24VDC NO Contact Relay Input Module
Relay Output Module Usage Precautions
Model List
Input Type Interface Module
2-2
Output Type Interface Module
2-2
DC I/O Conversion Module That Can Be Used Together
2-2
Module-to-Module Cable
2-2
Options
2-2
MELSEC-Q Series
2-3
MELSEC-L Series
2-3
MELSEC-AnS Series
2-4
Mitsubishi Electric CC-Link Remote I/O
2-5
Interface Module Selection Tips
No. of Cable(s) and Modules Used Based on the No. of I/O Points
2-6
Using an Interface Module and a DC I/O Conversion Module Together
2-6
2-7 to 9
Precautions Regarding DC Power Supply for Terminal Modules
2-10
Precautions Regarding AC Power Supply for Terminal Modules
2-10
Troubleshooting
2-11, 12
Individual Specifications
Input Type
Output Type
Selection Chart
2-7
2-13
2-14, 15
Module-to-Module Cable
2-16
Replacement Relay
2-17
7
Common Elements
& Appendix
6
Conversion Module
For MELSEC-L CPU
5
Cable For
Positioning Module
4
Conversion Module
For High-Speed Counter
3
Conversion Module
For Analog I/O
2
Interface Module For DC I/O
1
Conversion Module
For DC I/O
2. Interface Module for DC I/O
2-Contents
2. Interface Module for DC I/O
Overview
Overview
Terminal modules are used for isolation and conversion between MELSEC I/O module I/O signals and external I/O signals.
Only the 24VDC signals are used on the programmable controller side, and therefore different external signals can be also used.
●Input type
Output signal to programmable controller
24VDC
Interface Module For DC I/O
2
Input signal from contact, etc.
NO contact relay (24VDC)
●Output type
Input signal from programmable controller
24VDC
Output signal to load, etc.
NO contact relay
2-1
Model List
2-2
Model Selection
2-3
to
2-5
Individual Specifications
2-13
to
2-17
2. Interface Module for DC I/O
Model List
Model List 1
Input Type Interface Module
24VDC relay isolation type
NO contact input module
Model
FA-TH16XRA20S
Remarks
Programmable
Module Conversion
No. of
Module Module
controller
isolation
module
points connected module
socket replacement
method
type
16
+ common
input module
Relay
isolation
NO contact
relay
Output Type Interface Module
Product
Yes
Possible
Input circuit
method
+
terminal
screw
16-point
independent type
(Common to
+ common
/ - common)
M3
Page
2-13
For connectable I/O modules and cables, see the Selection Chart.
Shape
Model
Remarks
Programmable
Module Conversion
No. of
Module Module
controller
isolation
module
points connected module
socket replacement
method
type
FA-TH16YRA11S
16
Sink output
module
Relay
isolation
NO contact
relay
Yes
Possible
FA-TH16YRA20S
16
Sink output
module
Relay
isolation
NO contact
relay
Yes
Possible
Input circuit
method
+
terminal
screw
16-point
1-common
1-wire type
M3
16-point
independent type
M3
Page
2-14
Interface Module For DC I/O
Shape
2
Product
For connectable I/O modules and cables, see the Selection Chart.
Relay isolation type
NO contact output module
DC I/O Conversion Modules That Can Be Used Together
Product
Shape
For connectable I/O modules and cables, see the Selection Chart.
Model
Remarks
For X0 to XF / Y0 to YF
MELSEC-dedicated + screw
terminal block 16-point 1-wire
type module
FA-TB16XY
Note: X* and Y* indicate
MELSEC I/O
input/output device
numbers.
Page
This module is a MELSEC-dedicated 16-point connector terminal block
conversion module. The module branches the 32 points of the MELSEC
connector-type I/O module into 16-point units using a branch cable, allowing
separate use from other 16-point modules.
Module-to-Module Cable
Product
2-15
1-11
For connectable I/O modules and cables, see the Selection Chart.
Shape
Vertical branch cable for
MELSEC-dedicated I/O module
Horizontal branch cable for
Mitsubishi Electric CC-Link
remote I/O module
Model
Remarks
FA-CBL10FM2V
1m (39.38 inch)
FA-CBL20FM2V
2m (78.75 inch)
FA-CBL30FM2V
3m (118.12 inch)
FA-CBL50FM2V
5m (196.86 inch)
FA-CBL10FM2H
1m (39.38 inch)
FA-CBL20FM2H
2m (78.75 inch)
FA-CBL30FM2H
3m (118.12 inch)
Page
• This cable comes out out from the MELSEC-Q/AnS series FCN 40P
connector-type I/O module with a round 40-core cable, branching into two MIL 20P
connectors on the other cable end, each connecting to a MELSEC-dedicated
16-point conversion module.
• The 40-core cable is vertically comes out from the MELSEC-Q/AnS series FCN
40P connector-type I/O module.
• The cable cannot be used with general-purpose 20P conversion modules.
2-16
This cable leads out from the Mitsubishi Electric CC-Link FCN 40P connector-type
remote I/O module with a round 40-core cable , branching into two MIL 20P
connectors on the other cable end, each connecting to a MELSEC-dedicated
16-point conversion module.
2-16
Options
Product
Replacement relay
Shape
Model
FA-NYP24WK4
Remarks
Page
Normally open (NO) contact relay (quantity: 4, color: beige)
2-17
Model Selection
MELSEC-Q
2-3
MELSEC-L
2-3
MELSEC-AnS
2-4
CC-Link
2-5
2-2
2. Interface Module for DC I/O
Selection Chart
MELSEC-Q Series Selection Chart 1
Programmable Controller ↔ Interface Module
● Connection example: Connector type I/O module ↔ Interface module
QY41P + FA-CBL10FM2V + FA-TH16YRA20S × 2
Interface Module For DC I/O
Input/
Output
Input
Output
Combined
Programmable controller
module model
QX41
QX41-S1
QX41-S2
QX42
QX42-S1
QY41P
QY42P
2
QH42P
QX41Y41P
(Note 2)
(Note 2)
(Note 2)
(Note 2)
Input side
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TH16XRA20S
2-13
FA-CBL**FM2V (Note 1)
2-16
NO contact relay
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2V (Note 1)
2-16
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TH16XRA20S
2-13
FA-CBL**FM2V (Note 1)
2-16
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2V (Note 1)
2-16
Output side NO contact relay
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
MELSEC-Q Series Selection Chart 2
Programmable Controller ↔ Interface Module + Conversion Module
● Connection example: Connector type I/O module ↔ Interface module + DC I/O conversion module
QY41P + FA-CBL10FM2V + FA-TH16YRA20S + FA-TB16XY
FA-TH16YRA20S
FA-TB16XY
Input/
Output
Input
Output
Combined
Programmable controller
module model
QX41
QX41-S1
QX41-S2
QX42
QX42-S1
QY41P
QY42P
QH42P
QX41Y41P
(Note 2)
(Note 2)
(Note 2)
(Note 2)
Input side
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
NO contact relay
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
Output side NO contact relay
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
MELSEC-L Series Selection Chart 1
Programmable Controller ↔ Interface Module
● Connection example: Connector type I/O module ↔ Interface module
LY41NT1P + FA-CBL10FM2V + FA-TH16YRA20S × 2
Input/
Output
Input
Output
Programmable controller
module model
LX41C4
LX42C4
LY41NT1P
LY42NT1P
Positive common
dedicated
(Note 2)
(Note 2)
Conversion module type
24VDC NO contact
relay
NO contact relay
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
2-3
Conversion module model 1
Conversion module model 2
Connection cable
With socket
Independent FA-TH16XRA20S
2-13
FA-TH16XRA20S
2-13
FA-CBL**FM2V (Note 1)
2-16
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2V (Note 1)
2-16
2. Interface Module for DC I/O
Selection Chart
MELSEC-L Series Selection Chart 2
Programmable Controller ↔ Interface Module + Conversion Module
● Connection example: Interface Module ↔ DC I/O conversion module
LY41NTP + FA-CBL10FM2V + FA-TH16YRA20S + FA-TB16XY
FA-TH16YRA20S
Input/
Output
Input
Output
Programmable controller
module model
LX41C4
LX42C4
LY41NT1P
LY42NT1P
Positive common
dedicated
(Note 2)
(Note 2)
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
NO contact relay
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
2
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
Interface Module For DC I/O
FA-TB16XY
MELSEC-AnS Series Selection Chart 1
Programmable Controller ↔ Interface Module
● Connection example: Connector type I/O module ↔ Interface module
A1SY41P + FA-CBL10FM2V + FA-TH16YRA20S × 2
Input/
Output
Input
Output
Combined
Programmable controller
module model
A1SX41
A1SX41-S1
A1SX41-S2
A1SX42
A1SX42-S1
A1SX42-S2
A1SY41P
A1SY42P
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
(Note 2)
(Note 2)
(Note 2)
(Note 2)
A1SH42
(Note 2)
A1SH42-S1 (Note 2)
A1SH42P
(Note 2)
A1SH42P-S1 (Note 2)
Input side
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TH16XRA20S
2-13
FA-CBL**FM2V (Note 1)
2-16
NO contact relay
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2V (Note 1)
2-16
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TH16XRA20S
2-13
FA-CBL**FM2V (Note 1)
2-16
FA-TH16YRA11S
2-14
Independent FA-TH16YRA20S
2-15
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2V (Note 1)
2-16
1-wire type
Output side NO contact relay
With socket
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
MELSEC-AnS Series Selection Chart 2
Programmable Controller ↔ Interface Module + Conversion Module
● Connection example: Connector type I/O module ↔ Interface module + DC I/O conversion module
A1SY41P + FA-CBL10FM2V + FA-TH16YRA20S + FA-TB16XY
FA-TH16YRA20S
FA-TB16XY
Input/
Output
Input
Output
Programmable controller
module model
A1SX41
A1SX41-S1
A1SX41-S2
A1SX42
A1SX42-S1
A1SX42-S2
A1SY41P
A1SY42P
Conversion module type
Conversion module model 1
Conversion module model 2
Connection cable
(Note 2)
(Note 2)
(Note 2)
(Note 2)
A1SH42
(Note 2)
Combined A1SH42-S1 (Note 2)
A1SH42P
(Note 2)
A1SH42P-S1 (Note 2)
Input side
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
NO contact relay
With socket
1-wire type FA-TH16YRA11S
Independent FA-TH16YRA20S
2-14
2-15
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
24VDC NO contact
relay
With socket
Independent FA-TH16XRA20S
2-13
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
FA-TH16YRA11S
2-14
Independent FA-TH16YRA20S
2-15
FA-TB16XY
1-11
FA-CBL**FM2V (Note 1)
2-16
1-wire type
Output side NO contact relay
With socket
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
2-4
2. Interface Module for DC I/O
Selection Chart
Mitsubishi Electric CC-Link Remote I/O Selection Chart 1
Remote I/O ↔ Interface Module
● Connection example: Remote I/O module ↔ Interface module
AJ65SBTCF1-32T + FA-CBL10FM2H + FA-TH16YRA20S × 2
Interface Module For DC I/O
Input/
Output
Input
Output
Programmable controller
module model
AJ65SBTCF1-32D
AJ65BTC1-32D
AJ65SBTCF1-32T
AJ65BTC1-32T
Conversion module type
Conversion module model 1
Positive common 24VDC NO contact
With socket Independent FA-TH16XRA20S
dedicated
relay
(Note 2)
1-wire type FA-TH16YRA11S
NO contact relay
With socket
(Note 2)
Independent FA-TH16YRA20S
Conversion module model 2
Connection cable
2-13
FA-TH16XRA20S
2-13
FA-CBL**FM2H (Note 1)
2-16
2-14
2-15
FA-TH16YRA11S
FA-TH16YRA20S
2-14
2-15
FA-CBL**FM2H (Note 1)
2-16
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
2
Mitsubishi Electric CC-Link Remote I/O Selection Chart 2
Remote I/O ↔ Interface Module + Conversion Module
● Connection example: Remote I/O module ↔ Interface module + DC I/O conversion module
AJ65SBTCF1-32T + FA-CBL10FM2H + FA-TH16YRA20S + FA-TB16XY
FA-TH16YRA20S
FA-TB16XY
Input/
Output
Input
Output
Programmable controller
module model
AJ65SBTCF1-32D
AJ65BTC1-32D
AJ65SBTCF1-32T
AJ65BTC1-32T
Conversion module type
Note 1: Use the same power supply for two connected modules.
Note 2: For use with 24VDC only.
2-5
Conversion module model 1
Positive common 24VDC NO contact
With socket Independent FA-TH16XRA20S
dedicated
relay
(Note 2)
1-wire type FA-TH16YRA11S
NO contact relay
With socket
(Note 2)
Independent FA-TH16YRA20S
Conversion module model 2
Connection cable
2-13
FA-TB16XY
1-11
FA-CBL**FM2H (Note 1)
2-16
2-14
2-15
FA-TB16XY
1-11
FA-CBL**FM2H (Note 1)
2-16
2. Interface Module for DC I/O
Selection Tips
Interface Module Selection Tips
Number of cable(s) and modules used based on the number of I/O points
● The interface module is a 16-point module. The number of modules used varies according to the number of MELSEC I/O module
points used.
1) With a 32-point I/O module
Interface module
Connection cable
QY 1P
12 2 VDC
0 1A
FA-CBL***FM2V
1 cable
FA-TH16***
2 modules
Use the same 24VDC
external power supply.
PW
Connection cable
FA-CBL***FM2V
2 cables
QY42P
1 / 4VDC
0 1A
F
2
2) With a 64-point I/O module
Interface Module For DC I/O
QY41P
Interface module
FA-TH16***
4 modules
Use the same 24VDC
external power supply.
PW
QY4 P
DIS LAY
L
PW
0
1
2
3
5
6
7
8
A
C
D
F
Use the same 24VDC
external power supply.
P
Using an interface module and a DC I/O conversion module together
● The interface module is a 16-point module, allowing you to use the module together with a 16-point DC I/O conversion module.
1) When an interface module and a terminal block type conversion module are used together in a 32-point I/O module
Interface module
Connection cable
1 / 4VDC
0 1A
FA-TH16***
FA-CBL***FM2V
QY41P
QY41P
Use the same 24VDC
external power supply.
1 cable
2
0
Terminal block type conversion module
FA-TB16XY
2-6
2. Interface Module for DC I/O
Usage Precautions
Precautions when using a 24VDC NO contact relay input module
1) Relay switching frequency
Use the module with a maximum input signal switching frequency of one-second or longer ON, and one-second or longer OFF.
2) Input line surge / induced voltage
Interface Module For DC I/O
Do not install the 24VDC input signal line together with the main circuit lines, power cables, or the like, or wire the 24VDC input signal line close to such
wiring. As a general rule, keep a distance of 100mm or more between them.
Failure to do so may cause the input signal to turn ON when set to OFF, or not turn OFF when switched from ON to OFF due to the induced voltage from
the main circuit or power cables.
Such wiring may also cause a high surge voltage to occur during ON ↔ OFF of the main circuit, power cables, etc., thereby damaging the diode inserted
in parallel with the module relay.
Countermeasures
1) Arrange the input signal line far away from the main circuit, power cables, etc. (Do not make the input signal
lines, main circuit, power cable, etc., the same cable or install the cables together).
2) Insert a bleeder resistor in parallel with the input signal to lower the input impedance of the input signal.
Power cable
1)
Input module
2
Input signal line
RA
24VDC
power supply
●
Bleeder resistor
(1.2 to 2.7KΩ)
For the bleeder resistor, select a resistance value by starting from the large value and gradually decreasing it to find
the value at which malfunction does not occur.
Relay output module usage precautions
1) Relay switching frequency
Use the module with a maximum output signal switching frequency of one-second or longer ON, and one-second or longer OFF.
2) Relay contact locking
When the load of relay contact is a load indicated in the table below such as a timer, counter, or light bulb where the power supply uses AC/DC or DC/DC
of switching control, an inrush current may be introduced at relay ON, and the contact may be locked (remains ON without returning to OFF) due to
welding or transfer.
Light bulb
Approx. 10× to 15×
Capacitor (Note 1)
Approx. 20× to 50×
Solenoid
Approx. 10× to 20×
Electromagnetic contactor
Approx. 3× to 10×
Fluorescent lamp
Approx. 5× to 15× (Note 2)
Motor
Approx. 5× to 15×
Transformer
Approx. 5× to 15×
Mercury lamp
Approx. 3× (Note 2)
DC
AC
Rated current
1×
Rated current
Resistance
Inrush current waveform
Inrush current
Inrush current / Rated current
Inrush current
Load type
Note 1: The capacitor load includes the stray capacitance from capacitors and wiring, and the capacitive load of timers, counters, etc.
(where the power supply uses AC/DC or DC/DC of switching control).
Note 2: In the case of a discharge lamp such as a mercury lamp or fluorescent lamp, and in particular in a case where the power supply
impedance is low at a high power factor, a current of 20x to 40x may be introduced.
2-7
2. Interface Module for DC I/O
1)
1) Insert a resistor in series with the load.
2) Insert impedance in series with the load.
2)
Resistor
Output
module
-
Capacitive
load
+
Output
module
Impedance
-
Capacitive
load
+
Power supply
Power supply
3) Switching of slight current load
When a slight current load (5VDC or less or 1mA or less) is switched by an output relay, the load may not turn ON even if the relay turns ON due to poor
contact of the relay contact.
Countermeasures
1) Insert a dummy resistor in parallel with the load.
Output
module
-
+
Dummy
resistor
2
1)
Interface Module For DC I/O
Countermeasures
Usage Precautions
Load
Power supply
●
The load current at relay ON is increased, preventing poor contact.
4) Service life of relay contact
When the module is used in applications with high switching frequency by the output relay, the relay life becomes problematic. We therefore recommend
adequate investigation of usage conditions.
The relay life curve shows the actual service life, not a guaranteed life. Conduct investigations while applying an adequate margin to the relay life curve.
When the inductive load of an electromagnetic contactor, solenoid, or the like is disconnected, a high counter-electromotive force occurs between
contacts, generating an arc discharge. If the switching current is high, the power factor is low, or the time constant is high, the life shortens. Consideration
is required.
For inductive loads, we recommend using a protection circuit based on the surge absorbing circuit in the figure below.
Countermeasures
1) Insert a capacitor + resistor in parallel with the load (applicable to AC and DC loads).
2) Insert a capacitor + resistor in parallel with the contact (AC load: Note 1; applicable to DC loads).
Note 1: When used with AC voltage, verify that the load impedance is adequately smaller than the C and R impedance. (When the
contact is OFF, leakage current flows through C and R, causing a phenomenon in which the load is turned ON and, once ON,
does not turn OFF.)
1)
2)
Capacitor
Output
module
Resistor
-
Inductive
load
Output
module
+
Capacitor
Power supply
Inductive
load
Resistor
+
Power supply
The capacitor has the effect of suppressing electrical discharge at contact OFF, and the resistor has the effect of suppressing
current at contact ON.
The guidelines for element selection are as described below. Note, however, that the values differ according to variances in load
properties and characteristics. Check the values via experiments.
●
●
Capacitor: 0.5 to 1 (µF) for a contact current of 1A, Resistor: 0.5 to 1 (Ω) for a contact voltage of 1V
Use a capacitor withstand voltage of 200 to 300V, in general. In the case of an AC circuit, use an AC capacitor without polarity.
If the load is a relay or solenoid, the recovery time is delayed. Caution is required.
●
●
2-8
2. Interface Module for DC I/O
Countermeasures
Usage Precautions
3) Insert a diode in parallel with the load (applicable to DC loads)
3)
Output
module
Inductive
load
Diode
+
Power supply
When the contact turns OFF the energy stored in the inductive load, the energy flows to the load in the form of current by the
parallel diode and is consumed as Joule heat in an amount equivalent to the load resistance.
Use a diode with a peak inverse voltage of 10 times the power supply voltage or more, and a forward current of the load current or
more.
This method delays the recovery time more than the capacitor + resistor method.
●
Interface Module For DC I/O
●
●
Countermeasures
4) Insert a diode + Zener diode in parallel with the load (applicable to DC loads).
2
4)
Output
module
Inductive
load
Diode
+
Zener diode
Power supply
The parallel diode of 3) is effective when used in a case where the recovery time is delayed to an excessive degree.
For the Zener diode, use a Zener voltage equivalent to the power supply voltage or greater.
●
●
Countermeasures
5) Insert a varistor in parallel with the load or in parallel with the contact (applicable to AC or DC loads).
5)
Output
module
Varistor
-
+
Inductive
load
Power supply
Use the varistor constant voltage characteristics to ensure that high voltage is not added to the contact.
Connection between the loads is effective when the power supply voltage is 24 to 48V, and connection between the contacts is
effective when the power supply voltage is 100 to 200V.
Select a varistor cut voltage Vc within the conditions described below. Note that the effect lessens when Vc is too high.
With a DC power supply: Vc > Power supply voltage × 1.5, With an AC power supply: Vc > Power supply voltage × √2 × 1.5
If the load is a relay or solenoid, the recovery time is somewhat delayed.
●
●
●
●
5) Precautions
1) Avoid protection circuits that connect a capacitor in parallel with a contact.
Connecting a capacitor in parallel with the contact is extremely effective in arc extinction at the time of disconnection, but the load accumulates when
the contact is OFF, causing a short-circuit current of the capacitor to flow at contact ON and contact welding to occur more readily.
2) Avoid protection circuits that connect a capacitor in parallel with an inductive load.
Connecting a capacitor in parallel with an inductive load is extremely effective in arc extinction at the time of disconnection, but introduces a charging
current from the capacitor at contact ON, causing contact welding to occur more readily.
1)
Output
module
2)
Inductive
load
Capacitor
-
+
Power supply
Output
module
Capacitor
-
+
Inductive
load
Power supply
3) Install the protection circuit near the load or relay contact (module).
When the protection circuit is installed far away from the load or relay contact, the effect of the protection circuit cannot be adequately exhibited. As a
guide, install the circuit within 50cm.
2-9
2. Interface Module for DC I/O
Usage Precautions
Precautions regarding DC power supply for interface modules
Emean.
Emax. = Maximum value of pulsation portion
× 100%
Emean. = Mean value of pulsation portion
Emin.
= Minimum value of pulsation portion
Precautions regarding AC power supply for interface modules
1) For an AC power supply used for an interface module, use a power supply with a waveform distortion rate of
5% or less.
Interface Module For DC I/O
Emax. - Emin.
2
Ripple rate % =
DC portion
Pulsation
portion
Emin.
Emean.
Emax.
1) For the DC power supply used for an interface module, use a power supply with a ripple rate of 5% or less.
2-10
2. Interface Module for DC I/O
Usage Precautions
Troubleshooting
[ Input type interface module ]
The input signal does
not turn ON
Is the interface
module LED on?
YES
Interface Module For DC I/O
Is the
cable properly
connected?
NO
YES
Replace the cable with a spare cable and check
operation.
NO
Check if the programmable controller input module
is wrong.
Check if the connector is properly inserted and
locked.
2
Is the module
external power supply
on?
NO
YES
Check if the terminal block screws are loose and
thus have insufficient contact.
Is the input load
power supply on?
NO
YES
Check if the power supply voltage is correct.
Check the usage frequency and if the relay life has
expired.
Check if a surge voltage is applied from an
external source. Refer to “Interface Module Usage
Precautions” (Pages 2-7 to 2-10), check if the
usage conditions apply, and implement
countermeasures.
Check if there are operating environment factors
that lead to deterioration, such as organic silicon
or corrosive gases.
Check if the module is properly installed to the
socket.
Check if external wiring is properly connected, and
turn on the input load power supply.
Turn on the module external power supply.
The input signal does
not turn OFF
Is voltage applied to
the terminal between the signal
and common of the interface
module?
NO
YES
When a no-contact switch, LED display switch, or
the like is used for the externally connected switch,
leakage current may affect the module. Implement
countermeasures so that the voltage between the
interface module terminals is less than or equal to
the specification value of OFF voltage.
When wiring cable is routed, leakage current
caused by line capacity may affect the module.
Implement countermeasures so that the voltage
between the interface module terminals is less
than or equal to the specification value of OFF
voltage.
Contamination of wirechips
During wiring, be careful to ensure that wire chips
do not enter inside the interface module.
Check the usage frequency and verify that the
relay life has not expired.
2-11
2. Interface Module for DC I/O
Usage Precautions
[ Output type interface module ]
YES
NO
Verify that there is no poor contact due to loose
terminal block screws.
Is the output load
power supply on?
YES
Check if the external wiring is wired properly.
Check the usage frequency and verify that the
relay life has not expired.
NO
Check if surge voltage or inrush current is applied
from an external source. Refer to “Interface
Module Usage Precautions” (Pages 2-7 to 2-10),
check if the usage conditions apply, and
implement countermeasures.
2
Is the interface
module LED on?
Interface Module For DC I/O
The output does
not turn ON
Check if there are operating environmental factors
linked to deterioration, such as organic silicon or
corrosive gases.
Check if the module is properly mounted to the
socket.
Is the module
external power
supply on?
Check if the external wiring is properly connected,
and turn on the output load power supply.
YES
NO
Is the
cable properly
connected?
NO
YES
Check if the programmable controller output
module is wrong.
Check if the power supply voltage of the module
external power supply is correct.
Check if the connector is properly inserted and
locked.
Turn on the module external power supply.
The output does
not turn OFF
Is the interface
module LED off?
NO
YES
Check if the external wiring is wired properly.
Check the usage frequency and verify that the
relay life has not expired.
Check if surge voltage or inrush current is applied
from an external source. Refer to “Interface
Module Usage Precautions” (Pages 2-7 to 2-10),
check if the usage conditions apply, and
implement countermeasures.
Check if the programmable controller output
module is wrong.
Be careful that wirechips do not enter inside the
interface module during wiring when wire chips are
involved.
2-12
2. Interface Module for DC I/O (Input Type)
Individual Specifications
M3-screw 16-point 24VDC NO contact relay input (independent common; with sockets)
FA-TH16XRA20S
Features
Due to its independent common features, the points can be used separetely, such as 4 points/common.
The module is provided with sockets, allowing single relay replacement.
Related Materials
Selection Tips 2-6
Usage Precautions 2-7
General Specifications 7-1
Applicable Standards
Replacement Relay 2-17
Specifications
UL
7-2
cUL
CE
External Dimension
Specifications
1
2
3
4
5
6
7
8
9
A
B
C
D
E
5 (0.20)
8 (0.32)
100% (3-way installation)
41.5 (1.64)
Marking strip
DC DC X0 X0 X1 X1 X2 X2 X3 X3 X4 X4 X5 X5 X6 X6 X7 X7 X8 X8 X9 X9 XA XA XB XB XC XC XD XD XE XE XF XF
24V 0V (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+)
PW X0
X1
X2
X3
X4
X5
X6
X7
X8
X9
XA XB
XC
XD
XE
5
7
9
11
13
15
17
6
19
8
10
12
14
Connector
16
Wiring Diagram
18
19.2VDC or more / 8.1mA or more
2.4VDC or less / 1.0mA or less
Approx. 2.2kΩ
10ms or less (excluding programmable controller response time)
12ms or less (excluding programmable controller response time)
24VDC 1mA or more
3600 times/hour (1s or longer ON, 1s or longer OFF)
20 million times or more
100,000 times or more at 24VDC, 100mA power conduction (contact side)
16-point independent common
24VDC ±10% (within a ripple rate of 5%)
Approx. 10mA at 24VDC (not including current consumption of programmable controller)
Between each input, between external power supply and input
…2500VAC for 1 minute, 10MΩ or more
Simulator noise 500Vp-p, noise width 1µs
Noise resistance
(based on a noise simulator with a noise frequency of 25 to 60Hz)
LED on with power supply ON and input ON
Operation display
Yes (relay replaceable)
Socket
50 times
No. of times module is replaced
M3 spring-up screw, number of terminals: 34P,
Terminal screw
7.62-mm (0.3-inch) pitch
Terminal block
0.3 to 2mm2 (with solderless terminal use),
Applicable wire,
58.8 to 88.2Ncm (5.21 to 7.81lbf in)
tightening torque
Module
Screw installation M4 × 0.7mm × 22mm or more, tightening torque range: 78 to 118N cm (6.95 to 10.41lbf in)
TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
installation DIN rail
Relay extraction tool (mounted to relay)
Accessories
Approx. 300g
Weight
1. When connecting cables to the module, be sure to push in the cable connector until the
Precautions
connector locks. Failure to do so may cause poor contact.
8 (0.32)
F
35.5 (1.4)
0
15 (0.60)
8.5 (0.34)
PW
5 (0.20)
2-Φ4.5 installation holes
52 (2.05)
16 points
Relay
Voltage: 24VDC, Current: Approx. 10mA (24VDC)
21.6 to 26.4VDC [24VDC ±10% (within a ripple of 5%)]
Unit: mm (inch)
160 (6.30)
136 (5.36)
19 (0.75)
k
loc
ple
Sim 20°
1
Positive common 24VDC input module
20
2
Item
Connected programmable
controller
No. of points
Isolation method
Rated input voltage, current
Operating voltage range
Maximum number of points
simultaneously ON
ON voltage / ON current
OFF voltage / OFF current
Input impedance
Response
OFF→ON
time
ON→OFF
Minimum switching load
Maximum switching frequency
Mechanical life
Electrical life
Common method
External power supply
Module current consumption
Withstand voltage, insulation
resistance
1
2
3
4
Interface Module For DC I/O
Related Products
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal
XF
●
●
2 1
RA 0
+
RA 1
RA 2
Terminal block
Connection
example
+
24V
DC
+
+
24V
DC
+
24V
DC
Horizontal installation
RA 4
RA 5
RA 6
+
24V
DC
2-wire switch
With independent
input
Module Installation Direction
RA 3
RA 7
RA 8
RA 9
RA A
RA B
RA C
RA D
RA E
RA F
4 3
24VDC
0VDC
X0 (-)
X0 (+)
X1 (-)
X1 (+)
X2 (-)
X2 (+)
X3 (-)
X3 (+)
X4 (-)
X4 (+)
X5 (-)
X5 (+)
X6 (-)
X6 (+)
X7 (-)
X7 (+)
X8 (-)
X8 (+)
X9 (-)
X9 (+)
XA (-)
XA (+)
XB (-)
XB (+)
XC (-)
XC (+)
XD (-)
XD (+)
XE (-)
XE (+)
XF (-)
XF (+)
●
+
+
24V
DC
+
24V
DC
2-wire switch
With 4 points/common
input
+
24V
DC
+
+
24V
DC
24V
DC
24V
DC
3-wire switch
With independent
input
3-wire switch
With 4 points/common
input
How to Use the Extraction Tool
Vertical installation
PW
Removing the extraction tool
Installing the extraction tool
Operate and remove the tool using your fingers.
Operate and install the tool using your fingers.
E
C
D
PW
3
2
B
0
1
1
A
1
9
2
8
3
4
7
2
6
5
5
6
4
7
3
8
2
9
1
A
0
B
C
Inserting the relay into the socket
Insert the tool, and then insert the relay into the socket.
After insertion, remove the tool from the relay.
E
PW
D
Removing the relay from the socket
Insert the tool into the relay and pull using your fingers.
F
3
1
1
3
2
2
Note: Do not install the module in any direction other than the above.
2-13
Model Selection
MELSEC-Q
2-3
MELSEC-L
2-3
to
2-4
MELSEC-AnS
2-4
CC-Link
2-5
*Insert the relay after
first verifying that the
relay feet are not bent.
2. Interface Module for DC I/O (Output Type)
Individual Specifications
M3-screw 16-point NO contact relay output (independent common; with sockets)
FA-TH16YRA11S
Features
This module converts the input from the MELSEC sink-type transistor output module to NO contact relay output.
If a 64-point output programmable controller module is used, a maximum of 64 points of output can be converted in a
single slot.
Relays are replaceable on a per point basis (easy maintenance).
Related Materials
Related Products
Applicable Standards
Replacement Relay 2-17
Specifications
2-10
to
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal
UL
7-2
cUL
CE
External Dimension
PW
0 1
2 3 4
5
6 7
8 9
5 (0.20)
2-Φ4.5 installation holes
Noise resistance
Operation display
Socket
No. of times module is
replaced
41.5 (1.64)
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF COM COM
PW Y0 Y1 Y2
4
5
7
9
11
13
15
17
6
19
8
10
12
Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF
3
RA 0
50 times
14
Connector
16
Wiring Diagram
18
Response OFF→ON
ON→OFF
time
Common method
External power supply
Module current consumption
Withstand voltage,
insulation resistance
Marking strip
1
2
3
4
20
Electrical life
5 (0.20)
3600 times/hour (1s or longer ON, 1s or longer OFF)
k
loc
ple
Sim 120°
8 (0.32)
52 (2.05)
100%
5VDC 1mA
2700VAC, 150VDC
DC DC
24V 0V
15 (0.60)
A B C D E F
Voltage: 24VDC, 200VAC, Current: 2A/point (resistance load, COSΦ=1), 8A/common
20 million times or more
100,000 times or more at rated switching voltage/current
100,000 times or more at 200VAC 1.5A (COSΦ=0.7), 240VAC 1A (COSΦ=0.7)
100,000 times or more at 200VAC 1 A (COSΦ=0.35)
100,000 times or more at 24VDC 1A (L/R=7ms), 100VDC 0.1A (L/R=7ms)
10ms or less (excluding programmable controller response time)
12ms or less (excluding programmable controller response time)
16 points/common (1-wire type)
24VDC ±10% (within a ripple rate of 5%)
Approx. 90mA at 24VDC (not including current consumption of programmable controller)
Between input-output: 2500VAC for 1 minute,
between contacts: 750VA for 1 minute, 10MΩ or more
Simulator noise 1500Vp-p, noise width 1µs
(based on a noise simulator with a noise frequency of 25 to 60Hz)
LED on with power supply ON and input ON
Yes (relay replaceable)
8 (0.32)
16 points
Relay
Unit: mm (inch)
115 (4.53)
92.5 (3.65)
17.5 (0.69)
35.5 (1.4)
Sink-type 24VDC transistor output module
8.5 (0.34)
Specifications
Item
Connected programmable
controller
No. of points
Isolation method
Rated switching voltage,
current
Maximum number of
points simultaneously ON
Minimum switching load
Maximum switching load
Maximum switching
frequency
Mechanical life
Interface Module For DC I/O
Usage Precautions 2-7
2
Selection Tips 2-6
General Specifications 7-1
RA 1
RA 2
RA 3
RA 4
RA 5
RA 6
RA 7
RA 8
RA 9
RA A
RA B
RA C
RA D
RA E
RA F
2A 8A
+
1
M3 spring-up screw, number of terminals: 20P, 7.62-mm (0.3-inch) pitch
Terminal screw
0.3 to 2mm2 (with solderless terminal use),
Applicable wire,
Terminal block
58.8 to 88.2Ncm (5.21 to 7.81lbf in)
tightening torque
M4 × 0.7mm × 22mm or more, tightening torque range: 78 to 118N cm (6.95 to 10.41lbf in)
Module
Screw installation
TH35-7.5Fe,
TH35-7.5Al (IEC60715 compliant)
installation DIN rail
Relay extraction tool (mounted to relay)
Accessories
Approx. 240g
Weight
1. When connecting cables to the module, be sure to push in the cable connector until the
Precautions
connector locks. Failure to do so may cause poor contact.
2
COM
YF
Load
COM
YE
Load
YC
Load
Load
YD
YA
YB
Load
Load
Load
Y9
Y8
Load
Load
Load
Y7
Y6
Y4
Y5
Load
Load
Y2
Y3
Load
Y1
+
DC
24V
Load
Connection
example
Load
Terminal block
Load
●
24VDC
0VDC
Y0
●
●
AC or DC
power
supp y
Relay Characteristics Data
200
Switching life (10,000 times)
Contact current (A)
3
AC resistance load
2
1
DC resistance
load
0.5
0.3
0.2
0.1
10
Note 1: When the module is used in applications with high switching frequency, the relay life becomes problematic. We therefore
recommend adequate investigation of usage conditions.
NO contact life curve
Maximum value of switching capacity
5
20
30
50
100
200
Contact voltage (V)
300
400
Note 2: The relay life curve shows the actual service life, not a guaranteed life. Conduct your investigations while applying an
adequate margin to the relay life curve.
100
70
50
30
120VAC COSΦ=1
240VAC COSΦ=1
120VAC COSΦ=0.4
240VAC COSΦ=0.4
120VAC COSΦ=0.3
30VDC τ=7ms
240VAC COSΦ=0.3
120VAC COSΦ=0.2
20
100 to 120VDC
10 τ=7 to 40ms
7
5
240VAC COSΦ=0.2
3
τ (L/R) : Time constant
2 COSΦ : Power factor
1
0.1
0.2 0.3
0.5 0.7
30VDC τ=40ms
1
Module Installation Direction
Horizontal installation
5
Removing the extraction tool
Installing the extraction tool
Operate and remove the tool using your fingers.
Operate and install the tool using your fingers.
3
2
5 6 7 8 9 A B C D E F
PW
0 1
2 3 4 5 6 7 8 9 A B C D E F
2 3 4 5 6 7 8 9 A B C D E F
2 3
Vertical installation
0 1
0 1
3
How to Use the Extraction Tool
PW
PW
2
Switching current (A)
Note 3: The relay life varies significantly according to load type and inrush current characteristics. In particular, in rush current
may cause contact welding, and thus must be taken into consideration along with steady current.
a) Inductive load
When the inductive load of an electromagnetic contactor, solenoid, or the like is disconnected, a high
counter-electromotive force occurs between contacts, generating an arc discharge. In particular, if the power factor is
low, the life shortens. Such considerations must be taken into account. Additionally, at power activation, an inrush
current equivalent to 5 to 15 times that of a steady current is introduced, requiring considerations with regard to
contact welding.
b) Lamp load
A lamp circuit inrush current equivalent to 10 to 15 times that of a steady current is introduced, requiring
considerations with regard to contact welding.
c) Capacitive load
When there is a capacitor, etc., in the load circuit, an inrush current equivalent to 20 to 40 times that of a steady
current is introduced, requiring consideration with regard to contact welding. If the wiring is routed in a lengthy
manner, the power supply capacity also requires caution.
1
1
2
Removing the relay from the socket
Inserting the relay into the socket
Insert the tool into the relay and pull using your fingers.
Insert the tool, and then insert the relay into the socket.
After insertion, remove the tool from the relay.
3
Note: Do not install the module in any direction other than the above.
1
1
3
2
2
Model Selection MELSEC-Q
2-3
MELSEC-L
2-3
to
2-4
MELSEC-AnS
2-4
*Insert the relay after
first verifying that the
relay feet are not bent.
CC-Link
2-5
2-14
2. Interface Module for DC I/O (Output Type)
Individual Specifications
M3-screw 16-point NO contact relay output (independent common; with sockets)
FA-TH16YRA20S
Features
This module converts the input from the MELSEC sink-type transistor output module to NO contact relay output.
If a 64-point output programmable controller module is used, a maximum of 64 points of output can be converted in a
single slot.
Relays are replaceable on a per point basis (easy maintenance).
Related Materials
Selection Tips 2-6
Usage Precautions 2-7
General Specifications 7-1
Applicable Standards
Replacement Relay 2-17
Specifications
UL
7-2
cUL
CE
External Dimension
1
2
3
4
5
6
7
8
8 (0.32)
9
A
B
C
D
E
F
100%
Marking strip
3600 times/hour (1s or longer ON, 1s or longer OFF)
Noise resistance
Operation display
Socket
No. of times module is
replaced
PW Y0
4
Y1
2A
M3 spring-up screw, number of terminals: 34P, 7.62-mm (0.3-inch) pitch
Terminal screw
0.3 to 2mm2 (with solderless terminal use),
Applicable wire,
58.8 to 88.2Ncm (5.21 to 7.81lbf in)
tightening torque
M4 × 0.7mm × 22mm or more, tightening torque range: 78 to 118N cm (6.95 to 10.41lbf in)
Module
Screw installation
TH35-7.5Fe,
TH35-7.5Al (IEC60715 compliant)
installation DIN rail
Approx. 300g
Accessories
Relay extraction tool (mounted to relay)
Weight
1. When connecting cables to the module, be sure to push in the cable connector until the
Precautions
connector locks. Failure to do so may cause poor contact.
1
Y4
Y5
Y6
Y7
Y8
Y9
RA 3
RA 4
RA 5
RA 6
RA 7
RA 8
RA 9
5
7
9
11
13
15
17
6
19
8
10
Y3
YA YB YC YD YE YF
3
RA 0
50 times
Y2
12
Connector
14
Wiring Diagram
16
Response OFF→ON
ON→OFF
time
Common method
External power supply
Module current consumption
Withstand voltage,
insulation resistance
41.5 (1.64)
DC DC Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM Y8 COM Y9 COM YA COM YB COM YC COM YD COM YE COM YF COM
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
24V 0V
20 million times or more
100,000 times or more at rated switching voltage/current
100,000 times or more at 200VAC 1.5A (COSΦ=0.7), 240VAC (COSΦ=0.7)
100,000 times or more at 200VAC 1A (COSΦ=0.35)
100,000 times or more at 24VAC 1A (L/R=7ms), 100VAC 0.1A (L/R=7ms)
10ms or less (excluding programmable controller response time)
12ms or less (excluding programmable controller response time)
16 points independent common
24VDC ±10% (within a ripple rate of 5%)
Approx. 90mA at 24VDC (not including current consumption of programmable controller)
Between input-output, between each output: 2500VAC for 1 minute,
Between contacts: 750VAC for 1 minute, 10MΩ or more
Simulator noise 1500Vp-p, noise width 1µs
(based on a noise simulator with a noise frequency of 25 to 60Hz)
LED on with power supply ON and input ON
Yes (relay replaceable)
Electrical life
5 (0.20)
5VDC 1mA
270VAC, 150VDC
18
2
8 (0.32)
Voltage: 24VDC, 200VAC, Current: 2A/point (resistance load, COSΦ=1)
35.5 (1.4)
0
8.5 (0.34)
W
52 (2.05)
16 points
Relay
Unit: mm (inch)
15 (0.60)
5 (0.20)
2-Φ4.5 installation holes
160 (6.30)
136 (5.36)
19 (0.75)
Sink-type 24VDC transistor output module
k
loc
ple
Sim 120°
Specifications
Item
Connected programmable
controller
No. of points
Isolation method
Rated switching voltage,
current
Maximum number of
points simultaneously ON
Minimum switching load
Maximum switching load
Maximum switching
frequency
Mechanical life
1
2
3
4
20
Interface Module For DC I/O
Related Products
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal
RA 1
RA 2
RA A
RA B
RA C
RA D
RA E
RA F
2
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
24VDC
Load
Connection
example
Load
Terminal block
●
Load
●
●
24VDC
0VDC
Y0
COM0
Y1
COM1
Y2
COM2
Y3
COM3
Y4
COM4
Y5
COM5
Y6
COM6
Y7
COM7
Y8
COM8
Y9
COM9
YA
COMA
YB
COMB
YC
COMC
YD
COMD
YE
COME
YF
COMF
Terminal block
Relay Characteristics Data
Maximum value of switching capacity
5
Switching life (10,000 times)
3
Contact current (A)
Note 1: When the module is used in applications with high switching frequency, the relay life becomes problematic. We
therefore recommend adequate investigation of usage conditions.
Note 2: The relay life curve shows the actual service life, not a guaranteed life. Conduct your investigations while applying an
adequate margin to the relay life curve.
Note 3: The relay life varies significantly according to load type and inrush current characteristics. In particular, in rush current
may cause contact welding, and thus must be taken into consideration along with steady current.
a) Inductive load
When the inductive load of an electromagnetic contactor, solenoid, or the like is disconnected, a high
counter-electromotive force occurs between contacts, causing an arc discharge. In particular, if the power factor is
low, the life shortens. Such considerations must be taken into account. Additionally, at power activation, an inrush
current equivalent to 5 to 15 times that of a steady current is introduced, requiring considerations with regard to
contact welding.
b) Lamp load
A lamp circuit inrush current equivalent to 10 to 15 times that of a steady current is introduced, requiring
considerations with regard to contact welding.
c) Capacitive load
When there is a capacitor, etc., in the load circuit, an inrush current equivalent to 20 to 40 times that of a steady
current is introduced, requiring consideration with regard to contact welding. If the wiring is routed in a lengthy
manner, the power capacity also requires caution.
NO contact life curve
200
AC resistance load
2
1
DC resistance
load
0.5
0.3
0.2
0.1
10
20
30
50
100
200
Contact voltage (V)
300
400
100
70
50
30
120VAC COSΦ=1
240VAC COSΦ=1
120VAC COSΦ=0.4
240VAC COSΦ=0.4
120VAC COSΦ=0.3
30VDC τ=7ms
240VAC COSΦ=0.3
120VAC COSΦ=0.2
20
100 to 120VDC
10 τ=7 to 40ms
7
5
240VAC COSΦ=0.2
3
τ (L/R) : Time constant
2 COSΦ : Power factor
1
0.1
0.2 0.3
30VDC τ=40ms
0.5 0.7
1
Module Installation Direction
Horizontal installation
2
3
Switching current (A)
5
How to Use the Extraction Tool
Vertical installation
PW
Removing the extraction tool
Installing the extraction tool
Operate and remove the tool using your fingers.
Operate and install the tool using your fingers.
3
PW
2
0
1
1
2
1
3
4
2
5
6
7
8
9
A
B
C
Inserting the relay into the socket
Insert the tool, and then insert the relay into the socket.
After insertion, remove the tool from the relay.
E
PW
D
Removing the relay from the socket
Insert the tool into the relay and pull using your fingers.
F
3
1
1
3
2
2
Note: Do not install the module in any direction other than the above.
2-15
Model Selection
MELSEC-Q
2-3
MELSEC-L
2-3
to
2-4
MELSEC-AnS
2-4
CC-Link
2-5
*Insert the relay after
first verifying that the
relay feet are not bent.
2. Interface Module for DC I/O (Module-to-module Cable)
For MELSEC positive common input / sink output
Individual Specifications
(FCN 40P ↔ MIL 20P × 2, MIL 20P side branching type)
FA-CBL**FM2V
Specifications
D7920-B500FL, D3448-7920: Sumitomo 3M × 2
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
Insulator
Structure diagram
Conductor
Insulator
Related Materials
External Dimension
Unit: mm (inch)
Programmable controller side
Cable length
150 (5.91)
A
View
CON1
B
A1
B20
B1
20
Vie
w
A20
Weight
Approx. 160g
Approx. 270g
Approx. 380g
Approx. 600g
Wiring Diagram
Conductor
7-1
1m (39.38 inch)
2m (78.75 inch)
3m (118.12 inch)
5m (196.86 inch)
Twisted pair wire
Combined use with a DC I/O conversion
module is also possible.
General Specifications
Cable length
2
19
1
Note 1: A of the 20P connector corresponds to inputs X0 to XF / outputs Y0 to YF, and B
of the 20P connector corresponds to inputs X10 to X1F / outputs Y10 to Y1F.
CON1
MIL 20P
Connector A
CON1
MIL 20P
Connector B
B1
2
B2
2
A1
4
A2
4
B3
1
A3
1
B4
3
A4
3
B5
5
A5
5
B6
7
A6
7
B7
9
A7
9
B8
11
A8
11
B9
13
A9
13
B10
15
A10
15
B11
17
A11
17
B12
19
A12
19
B13
6
A13
6
B14
8
A14
8
B15
10
A15
10
B16
12
A16
12
B17
14
A17
14
B18
16
A18
16
B19
18
A19
18
B20
20
A20
20
Interface Module For DC I/O
This cable is used to connect a MELSEC
series FCN 40P connector-type I/O module
and terminal modules.
FCN367J040-AU/MW: Fujitsu Component
2
Features
Model
FA-CBL10FM2V
FA-CBL20FM2V
FA-CBL30FM2V
FA-CBL50FM2V
Specifications
Item
Programmable controller-side
connector
Module-side connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
FA-CBL**FM2H
Specifications
Specifications
Item
Programmable controller-side
connector
Module-side connector
Used cable
Conductor configuration
Insulator outer diameter
Cable outer diameter, color
Rated current
Conductor resistance (20˚C)
Dielectric withstand voltage
Insulation resistance
UL standard (cable area)
Features
This cable is used to connect a Mitsubishi
Electric CC-Link FCN 40P connector-type
remote I/O module and terminal modules.
Combined use with a DC I/O conversion
module is also possible.
D7920-B500FL, D3448-7920: Sumitomo 3M × 2
Round 40-core cable (black)
7/0.127 wires/mm (AWG#28)
0.88mm (0.04 inch)
9.5mm (0.38 inch) (standard), black
1A
0.232Ω/m or less
500VAC for 1 minute
5MΩ-km or more
UL STYLE NO 2464 80°C 300V
Cable jacket
Insulator
Structure diagram
MIL 20P
Connector A side
CON1
MIL 20P
Connector B side
2
B2
2
Insulator
A1
4
A2
4
Conductor
B3
1
A3
1
B4
3
A4
3
B5
5
A5
5
B6
7
A6
7
B7
9
A7
9
B8
11
A8
11
Unit: mm (inch)
Cable length
150 (5.91)
CON1
A
B1
A20
B20
B
w
Vie
A1
20
19
2
1
Note 1: A of the 20P connector corresponds to inputs X0 to XF / outputs Y0 to YF, and B
of the 20P connector corresponds to inputs X10 to X1F / outputs Y10 to Y1F.
Model Selection MELSEC-Q
2-3
Weight
Approx. 150g
Approx. 270g
Approx. 380g
B1
External Dimension
Programmable controller side
1m (39.38 inch)
2m (78.75 inch)
3m (118.12 inch)
CON1
Conductor
Vie
w
7-1
Cable length
Wiring Diagram
Twisted pair wire
Related Materials
General Specifications
Model
FA-CBL10FM2H
FA-CBL20FM2H
FA-CBL30FM2H
FCN367J040-AU/MW: Fujitsu Component
MELSEC-L
2-3
to
B9
13
A9
13
B10
15
A10
15
B11
17
A11
17
B12
19
A12
19
B13
6
A13
6
B14
8
A14
8
B15
10
A15
10
B16
12
A16
12
B17
14
A17
14
B18
16
A18
16
B19
18
A19
18
B20
20
A20
20
2-4
MELSEC-AnS
2-4
CC-Link
2-5
2-16
2. Interface Module for DC I/O (Replacement Relay)
Replacement relay
FA-NYP24WK4
Features
This relay is used for socket-type interface module maintenance.
Specifications
Interface Module For DC I/O
Item
Model
Module type
Module color
Quantity in package
Weight
Specifications
FA-NYP24WK4
NO contact relay
Beige
4
Approx. 30g
2
2-17
Model Selection
MELSEC-Q
2-3
MELSEC-L
2-3
2-4
MELSEC-AnS
2-4
CC-Link
2-5
Individual Specifications
2
Interface Module For DC I/O
2. Interface Module for DC I/O
2-18
3. Conversion Module for Analog I/O
Conversion Module
For DC I/O
1
Interface Module For DC I/O
2
Conversion Module
For Analog I/O
3
Conversion Module
For High-Speed Counter
4
Cable For
Positioning Module
5
Conversion Module
For MELSEC-L CPU
6
Common Elements
& Appendix
7
3-Contents
Contents
Overview
Selection Chart
Terminal Block Type Conversion Module for Isolated Analog Module
3-1
Terminal Block Type Conversion Module for Isolated
RTD (Resistance Temperature Detector) Input Module etc.
3-1
Conversion Module and Cable for Isolated Analog Module
3-3
Conversion Module and Cable for Isolated Thermocouple Input Module
3-3
Conversion Module and Cable for Isolated RTD Input Module
3-3
Individual Specifications
Model List
Conversion Module and Cable for Isolated Analog Module
3-2
Conversion Module and Cable for Isolated Analog Module
3-5
Conversion Module and Cable for Isolated Thermocouple Input Module
3-2
Conversion Module and Cable for Isolated Thermocouple Input Module
3-6
Conversion Module and Cable for Isolated RTD Input Module
3-2
Conversion Module and Cable for Isolated RTD Input Module
3-7
7
Common Elements
& Appendix
6
Conversion Module
For MELSEC-L CPU
5
Cable For
Positioning Module
4
Conversion Module
For High-Speed Counter
3
Conversion Module
For Analog I/O
2
Interface Module For DC I/O
1
Conversion Module
For DC I/O
3. Conversion Module for Analog I/O
3-Contents
3. Conversion Module for Analog I/O
Overview
Terminal block type conversion module for isolated analog module
This conversion module is used as a relay terminal block for a MELSEC-Q series isolated analog module or the like (connector type). Since the
programmable controller module is a connector type, conversion to a terminal block makes it possible to reduce the wiring work.
Connector
assembly
Connector
Wires
One-touch
connection using
cable with
connector
Wiring to
terminals
Wiring to
terminals
Analog signal lines
Analog signal lines
Conversion Module
For Analog I/O
3
Terminal block type conversion module for isolated RTD (resistance temperature detector)
input module etc.
This conversion module is used as relay terminal blocks for thermocouple, compensating lead wire, and RTD (resistance temperature detector)
connection.
Installing the module away from heating elements, fans, and the like inside the control panel makes it possible to measure the temperature without any
impact from heat.
The dedicated connection cable can be used in place of a compensating lead wire.
Connector
assembly
Connector
Wires
One-touch
connection using
cable with
connector
Wiring to
terminals
Wiring to
terminals
3-1
Model List
3-2
Model Selection
3-3
Individual Specifications
3-5
to
3-7
3. Conversion Module for Analog I/O
Model List
Model List
● Conversion module and cable for isolated analog module
Product
Shape
Terminal block type conversion
module for MELSEC-Q series
isolated analog module
Connection cable for MELSEC-Q
series isolated analog module
Model
Page
Remarks
FA-LTB40ADGN
MELSEC-Q series Q68AD-G terminal block type conversion module
FA-LTB40ADDG
MELSEC-Q series Q66AD-DG terminal block type conversion module
FA-LTB40DAG
MELSEC-Q series Q66DA-G terminal block type conversion module
FA-CBL20Q68ADGN
2m (78.75 inch)
FA-CBL30Q68ADGN
3m (118.12 inch)
FA-CBL20Q66ADDG
2m (78.75 inch)
FA-CBL30Q66ADDG
3m (118.12 inch)
FA-CBL20Q66DAG
2m (78.75 inch)
FA-CBL30Q66DAG
3m (118.12 inch)
3-5
Used for connecting MELSEC-Q series Q68AD-G and FA-LTB40ADGN
Used for connecting MELSEC-Q series Q66AD-DG and FA-LTB40ADDG
3-5
Used for connecting MELSEC-Q series Q66DA-G and FA-LTB40DAG
● Conversion module and cable for isolated thermocouple input module
Terminal block type conversion
module for isolated thermocouple
input module
FA-LTB40TDG
FA-CBL20Q68TDG
Page
Remarks
Model
MELSEC-Q series Q68TD-G-H01/H02 terminal block conversion module
(without cold junction compensation resistor)
3-6
2m (78.75 inch)
Connection cable for isolated
thermocouple input module
Used for connecting MELSEC-Q series Q68TD-G-H01/H02 and
FA-LTB40TDG
FA-CBL30Q68TDG
Conversion Module
For Analog I/O
Shape
3-6
3
Product
3m (118.12 inch)
● Conversion module and cable for isolated RTD input module
Product
Terminal block type conversion
module for MELSEC-Q series
Q68RD3-G
Shape
FA-LTB40RD3G
FA-CBL20Q68RD3G
Page
Remarks
Model
3-7
MELSEC-Q series Q68RD3-G terminal block conversion
2m (78.75 inch)
Connection cable for MELSEC-Q
series Q68RD3-G
Used for connecting MELSEC-Q series Q68RD3-G and FA-LTB40RD3G
FA-CBL30Q68RD3G
3-7
3m (118.12 inch)
Model Selection
3-3
3-2
3. Conversion Module for Analog I/O
Selection Chart
Selection Chart
● Conversion module and cable for isolated analog module
Mitsubishi Electric MELSEC-Q series
analog input module
Mitsubishi Electric MELSEC-Q series
analog output module
Conversion module
Connection cable
Q68AD-G
FA-CBL**Q68ADGN
3-5
FA-LTB40ADGN
3-5
Q66AD-DG
FA-CBL**Q66ADDG
3-5
FA-LTB40ADDG
3-5
FA-CBL**Q66DAG
3-5
FA-LTB40DAG
3-5
Q66DA-G
Q 8AD G
UN
A M
RR
Q 8 D
● Conversion module and cable for isolated thermocouple input module
Connection cable
Mitsubishi Electric MELSEC-Q series
isolated thermocouple input module
Q68TD-G-H01
Q68TD-G-H02
FA-CBL**Q68TDG
Conversion module
Conversion Module
For Analog I/O
3-6
FA-LTB40TDG
3-7
FA-LTB40RD3G
3-6
Q6 TD G H01
R N
LM
E R
6 TD
0
3
● Conversion module and cable for isolated RTD input module
Connection cable
Mitsubishi Electric MELSEC-Q series
isolated RTD input modules
FA-CBL**Q68RD3G
Q68RD3-G
6 RD3 G
R N
LM
E R
8R 3
3-3
Conversion module
3-7
3
Conversion Module
For Analog I/O
3. Conversion Module for Analog I/O
3-4
3. Conversion Module for Analog I/O
Individual Specifications
For MELSEC-Q Isolated Analog
Individual Specifications
Terminal block type conversion module
FA-LTB40ADGN/ADDG/DAG
Related Materials
Features
General Specifications 7-1
This module converts
module input using a
terminal block, simplifying
wiring.
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
Applicable Standards
UL
cUL
External Dimension
●
Conversion Module
For Analog I/O
●
1. When connecting cables to the module, be sure to push in the cable connector until the
connector locks. Failure to do so may cause poor contact.
3
Module Installation Tips
When installing models that
have screw installation
holes on both module sides
adjacent to each other on a
DIN rail, the models can be
installed close together as
shown on the right.
4
5
6
7
8
9
10
1
11
18 (0.71)
4.5
(0.18)
40
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
39
31
30
32
33
34
35
36
37
38
39
35
(1.38)
3
40
7.62 (0.30)
14.3
(0.57)
5.5
(0.22)
●
●
Precautions
2
7.5
(0.30)
Specifications
FA-LTB40ADGN
FA-LTB40DAG
FA-LTB40ADDG
Q68AD-G
Q66DA-G
Q66AD-DG
Terminal screw
M3 regular screw, 7.62-mm (0.3-inch) pitch
Applicable wire,
Terminal block
0.3 to 2mm2 (with solderless terminal use),
tightening torque
50 to 75N cm (4.52 to 6.59lbf in)
M4 × 0.7mm × 8mm or more,
Screw installation
tightening torque range: 78 to 118N cm (6.95 to 10.41lbf in)
Module installation
DIN rail
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
Withstand voltage,
Between CHs: 1000VAC for 1 minute, 10MΩ or more,
insulation resistance
Other: 500VAC for 1 minute, 10MΩ or more
Weight
Approx. 240g
Approx. 240g
Approx. 240g
2
1
44.7 (1.76)
47 (1.86)
k
loc
le °)
p
Sim (120
Item
Model
Connected module
Unit: mm (inch)
191 (7.52)
181 (7.13)
169 (6.66)
4 (0.16)
Specifications
29 (1.15)
2-Φ4.5 × 5.1 long installation holes
External Connection
For wiring to the terminal block, see the manual of the analog module to be connected, published by Mitsubishi Electric.
For the external wiring method when using a dedicated cable
(FA-CBL*Q68DGN), connect the terminals as described below.
Current input … Connect the V+ and Is terminals.
Voltage input … Do not connect wiring to the Is and I+ terminals.
*Is terminal: A dedicated terminal that connects with the V+ terminal
when using current input.
Current input
Voltage input
Is
V+
V+
V− / I−
I+
I−
I+
Is
V− / I−
I+
V+ V−
[FA-LTB40ADGN]
1
CH1
V+
1
1
2
2
3
CH1
Is
2
CH1
V−/I−
Applicable model
● FA-LTB**
5
CH2
V+
4
CH1
I+
7
CH2
Is
6
CH2
V−/I−
9
11
CH3
V+
8
CH2
I+
10
13
CH3
Is
12
CH3
V−/I−
15
CH4
V+
14
CH3
I+
17
CH4
Is
16
CH4
V−/I−
19
21
CH5
V+
18
CH4
I+
20
23
CH5
Is
22
CH5
V−/I−
25
CH6
V+
24
CH5
I+
27
CH6
Is
26
CH6
V−/I−
29
28
CH6
I+
31
CH7
V+
30
33
CH7
Is
32
CH7
V−/I−
35
CH8
V+
34
CH7
I+
37
CH8
Is
36
CH8
V−/I−
39
38
CH8
I+
40
[FA-LTB40ADDG]
1
CH1
P
3
I−
/CHK−
2
4
I+
/CHK+
5
7
CH2
P
6
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
I−
I−
I−
I−
I−
CH6
CH3
CH4
CH5
24VDC
P
P
P
P
/CHK−
/CHK−
/CHK−
/CHK−
/CHK−
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
I+
I+
I+
I+
I+
DC24G
/CHK+
/CHK+
/CHK+
/CHK+
/CHK+
[FA-LTB40DAG]
1
CH1
V+
3
CH1
I+
2
5
4
7
CH2
V+
6
COM1
9
CH2
I+
8
11
10
13
CH3
V+
12
COM2
15
CH3
I+
14
17
16
19
CH4
V+
18
COM3
21
CH4
I+
20
23
22
25
CH5
V+
24
COM4
27
CH5
I+
26
29
28
31
CH6
V+
30
COM5
33
CH6
I+
32
35
37
39
24VDC
34
36
38
40
DC24G
COM6
Ground the shielded wire in the same manner as the programmable controller module.
When grounding is not performed and the extra wire is rolled up, the wire may act as an antenna, possibly introducing noise.
Caution is required.
Connection cable
FA-CBL*Q68ADGN, FA-CBL*Q66ADDG/DAG
Features
External Dimension
Unit: mm (inch)
Cable length
130 (5.12)
50 (1.97)
Connected module
Used solderless
terminal
**
20
30
Specifications
FA-CBL**Q66ADDG
Between Q66AD-DG
and FA-LTB40ADDG
FA-CBL**Q66DAG
Between Q66DA-G
and FA-LTB40DAG
M4 round solderless terminal
Model
Cable length
2m (78.75 inch)
3m (118.12 inch)
FA-CBL**Q68ADGN FA-CBL**Q66ADDG
Weight
Weight
Approx. 300g
Approx. 300g
Approx. 400g
Approx. 400g
FA-CBL**Q66DAG
Weight
Approx. 300g
Approx. 400g
300 (11.82)
Shielded wire
(with M4 round solderless terminal)
65 (2.56)
18 (0.71)
SLD
FA-CBL**Q68ADGN
Between Q68AD-G
and FA-LTB40ADGN
Φ7.4
(1.8
7-1
Specifications
Item
Model
6 (0.24)
47
General Specifications
6)
Related Materials
50 (1.97)
5.3 (2.18)
This cable is a shielded
twisted pair cable, and is
provided with a solderless
terminal for shield grounding.
SLD
300 (11.82)
Shielded wire
(with M4 round solderless terminal)
Precautions
● FA-LTB40ADGN, FA-CBL**Q68ADGN
Replacing a conventional FA-LTB40ADG or FA-CBL**Q68ADG (production cancelled) product without an N at the end of the
model name
Use in combination with the conventional product is not permitted
(Example: Combining FA-LTB40ADGN + FA-CBL**Q68ADG…Not available)
The external wiring method differs from that of a conventional products. At the time of replacement, verify the wiring of
FA-LTB40ADGN.
● FA-LTB40DAG, FA-CBL**Q66DAG
When using a conversion module or cable, errors may occur in the Q66DA-G conversion characteristics due to the impact of a
drop in voltage caused by wiring resistance. Be sure to take voltage drops caused by wiring resistance into adequate
consideration.
Target: Q66DA-G, Conditions: Voltage output and when the load resistance is 50kΩ or less
Wiring resistance reference value ... Cable resistance value: 226Ω/km (20˚C)
Conversion module + Cable (3m) resistance value: 0.867Ω or less
3-5
Model Selection
3-3
3. Conversion Module for Analog I/O
Isolated Thermocouple Input Conversion Module
& Cable Individual Specifications
Individual Specifications
Terminal block type conversion module
FA-LTB40TDG
Features
With this conversion module connected, programmable controller accuracy specifications are satisfied.
The module is capable of measurement without impact from heat when installed away from heating elements inside the
control panel.
Related Materials
General Specifications
Applicable Standards
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
7-1
Specifications
5
6
7
8
9
10
1
11
18 (0.71)
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
39
31
30
32
33
34
35
36
37
38
39
40
7.62 (0.30)
●
4.5
(0.18)
40
12
35
(1.38)
4
14.3
(0.57)
5.5
(0.22)
External Connection
Install the module in a location that has a uniform ambient temperature.
Connect the thermocouple or compensating lead wire directly to the terminal block.
Ground the shielded wire in the same manner as the programmable controller module. When grounding is not performed and
the extra wire is rolled up, the wire may act as an antenna, possibly introducing noise. Caution is required.
When installing models that have screw installation holes on both module sides adjacent to each other
on a DIN rail, the models can be installed close together as shown below.
1
2
Conversion Module
For Analog I/O
●
Module Installation Tips
2
3
●
1. When connecting cables to the module, be sure to push in the cable connector until the
connector locks. Failure to do so may cause poor contact.
1
2
7.5
(0.30)
●
2
1
3
Withstand voltage,
insulation resistance
Weight
M3 regular screw, 7.62-mm (0.3-inch) pitch
0.3 to 2mm2 (with solderless terminal use),
50 to 75Nc m (4.52 to 6.59lbf in)
M4 × 0.7mm × 8mm or more,
tightening torque range: 78 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
Between CHs: 1000VAC for 1 minute, 10MΩ or more,
Other: 500VAC for 1 minute, 10MΩ or more
Approx. 240g
44.7 (1.76)
47 (1.86)
k
loc
le )
p
°
Sim (120
Screw installation
29 (1.15)
Terminal screw
Applicable wire,
tightening torque
Unit: mm (inch)
191 (7.52)
181 (7.13)
169 (6.66)
None (uses the resistor provided with the programmable controller)
DIN rail
Precautions
2-Φ4.5 × 5.1 long installation holes
4 (0.16)
Module installation
cUL
External Dimension
Specifications
Q68TD-G-H01, Q68TD-G-H02
Item
Connected module
Cold junction
compensation
resistance
Terminal block
UL
For the cold junction compensation resistor (RTD), connect the Q68TD-G-H01/H02 accessory between terminal numbers 38
and 40 as shown below. Terminal numbers 39 (RTD G) and 40 (RDT-) are connected inside the conversion module, and
therefore do not require external wiring.
1
CH1
+
Applicable model
● FA-LTB**
3
2
CH1
-
4
5
CH2
+
7
6
CH2
-
8
9
CH3
+
11
10
CH3
-
12
13
CH4
+
15
14
CH4
-
16
17
CH5
+
19
18
CH5
-
21
CH6
+
20
23
22
CH6
-
24
25
CH7
+
27
26
CH7
--
28
29
CH8
+
31
30
CH8
-
33
32
35
34
37
36
38
RTD
+
39
RTD
G
40
RTD
-
RTD
Connection cable
FA-CBL*Q68TDG
Features
This cable is used in place of the compensating lead wire between the conversion module and programmable controller
module.
The cable is a shielded instrumentation cable, and provides a solderless terminal for shield grounding.
Related Materials
General Specifications
Specifications
External Dimension
Specifications
Unit: mm (inch)
Cable length
130 (5.12)
50 (1.97)
6 (0.24)
5.3 (2.18)
6)
Φ7.4
50 (1.97)
(1 8
SLD
300 (11.82)
Shielded wire
(with M4 round solderless terminal)
65 (2.56)
18 (0.71)
FA-CBL20Q68TDG
FA-CBL30Q68TDG
Between Q68TD-G-H01/H02 and FA-LTB40TDG
2m (78.75 inch)
3m (118.12 inch)
M4 round solderless terminal
Approx. 300g
Approx. 400g
47
Item
Model
Connected module
Cable length
Used solderless terminal
Weight
7-1
SLD
300 (11.82)
Shielded wire
(with M4 round solderless terminal)
Model Selection
3-3
3-6
3. Conversion Module for Analog I/O
Isolated Resistance Temperature Detector
Input Conversion Module & Cable
Individual Specifications
Terminal block conversion module
FA-LTB40RD3G
Features
With this conversion module connected, programmable controller accuracy specifications are satisfied.
Related Materials
General Specifications
Applicable Standards
7-1
Specifications
●
2
3
4
5
6
7
Conversion Module
For Analog I/O
Between CHs: 1000VAC for 1 minute, 10MΩ or more,
Other: 500VAC for 1 minute, 10MΩ or more
Approx. 240g
Withstand voltage,
insulation resistance
Weight
18 (0.71)
2
1
8
9
10
1
11
4.5
(0.18)
40
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
39
31
30
32
33
34
35
36
37
38
39
35
(1.38)
●
44.7 (1.76)
40
7.62 (0.30)
1. When connecting cables to the module, be sure to push in the cable connector until the
connector locks. Failure to do so may cause poor contact.
7.5
(0.30)
Screw installation
●
Unit: mm (inch)
191 (7.52)
181 (7.13)
169 (6.66)
47 (1.86)
k
loc
le °)
p
Sim (120
●
DIN rail
Precautions
cUL
4 (0.16)
Terminal screw
Applicable wire,
tightening torque
2-Φ4.5 × 5.1 long installation holes
29 (1.15)
Module installation
UL
External Dimension
Specifications
Q68RD3-G
M3 regular screw, 7.62-mm (0.3-inch) pitch
0.3 to 2mm2 (with solderless terminal use),
50 to 75Nc m (4.52 to 6.59lbf in)
M4 × 0.7mm × 8mm or more,
tightening torque range: 78 to 118N cm (6.95 to 10.41lbf in)
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
Item
Connected module
Terminal block
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
14.3
(0.57)
5.5
(0.22)
External Connection
Module Installation Tips
3
When installing models that have screw installation holes on both module sides adjacent to each other
on a DIN rail, the models can be installed close together as shown below.
Ground the shielded wire in the same manner as the programmable controller module. When grounding is not performed and
the extra wire is rolled up, the wire may act as an antenna, possibly introducing noise. Caution is required.
For wiring to the terminal block, see the manual of the connected RTD input module published by Mitsubishi Electric.
1
CH1
A1
1
1
2
2
App icable model
● FA-LTB**
2
CH1
B1
3
CH1
b1
5
4
6
CH2
A2
7
CH2
B2
9
8
CH2
b2
10
11
CH3
A3
12
CH3
B3
13
CH3
b3
15
14
16
CH4
A4
17
CH4
B4
19
18
CH4
b4
21
CH5
A5
20
23
CH5
b5
22
CH5
B5
25
24
26
CH6
A6
27
CH6
B6
29
28
CH6
b6
30
31
CH7
A7
32
CH7
B7
33
CH7
b7
35
34
36
CH8
A8
37
CH8
B8
39
38
CH8
b8
40
Connection cable
FA-CBL*Q68RD3G
Features
This cable is a shielded twisted pair cable, and provides a solderless terminal for shield grounding.
Related Materials
General Specifications 7-1
Specifications
External Dimension
Specifications
FA-CBL30Q68RD3G
Between Q68RD3-G and FA-LTB40RD3G
2m (78.75 inch)
3m (118.12 inch)
50 (1.97)
(1.8
Approx. 400g
6 (0.24)
Φ7.4
50 (1.97)
SLD
300 (11.82)
Shielded wire
(with M4 round solderless terminal)
3-7
Model Selection
3-3
65 (2.56)
18 (0.71)
47
Approx. 300g
130 (5.12)
6)
M4 round solderless terminal
Unit: mm (inch)
Cable length
FA-CBL20Q68RD3G
5.3 (2.18)
Item
Model
Connected module
Cable length
Used solderless terminal
Weight
SLD
300 (11.82)
Shielded wire
(with M4 round solderless terminal)
3
Conversion Module
For Analog I/O
3. Conversion Module for Analog I/O
3-8
4. Conversion Module for High-Speed Counter
Conversion Module
For DC I/O
1
Interface Module For DC I/O
2
Conversion Module
For Analog I/O
3
Conversion Module
For High-Speed Counter
4
Cable For
Positioning Module
5
Conversion Module
For MELSEC-L CPU
6
Common Elements
& Appendix
7
4-Contents
Contents
Selection Chart
Overview
Conversion Module For High-Speed Counter
4-1
4-1
Individual Specifications
Model List
Conversion Module For High-Speed Counter
Conversion Module For High-Speed Counter
4-1
Conversion Module For High-Speed Counter
4-2
7
Common Elements
& Appendix
6
Conversion Module
For MELSEC-L CPU
5
Cable For
Positioning Module
4
Conversion Module
For High-Speed Counter
3
Conversion Module
For Analog I/O
2
Interface Module For DC I/O
1
Conversion Module
For DC I/O
4. Conversion Module for High-Speed Counter
4-Contents
4. Conversion Module for High-Speed Counter
Overview, Model List, and Selection Chart
Overview
The high-speed counter conversion module is used as a relay terminal block for signal connection from a pulse generating device.
The applicable high-speed counter modules include MELSEC-Q series QD62, QD62E, and QD62D.
Connector
assembly
Connector
Wires
One-touch
connection
with cable with
connector
Wiring to
terminals
Wiring to
terminals
Pulse signal lines
Pulse signal lines
Conversion Module
For High-Speed Counter
Model List
Product
Terminal block type conversion
module for MELSEC-Q series
high-speed counter module
(screw terminal block)
4
Connection cable for MELSEC-Q
series high-speed counter
module
Shape
Model
Remarks
Page
FA-TBS40P
This module is used to convert the input from the MELSEC-Q series high-speed counter
FA-SCBL10FMV-M
1m (39.38 inch) • A connection cable between QD62, QD62E, or QD62D ↔ Conversion
module
• Used conversion module: FA-TBS40P
2m (78.75 inch) • Shielded cable (with FG wire on both ends)
module QD62, QD62E, or QD62D using a screw terminal block.
FA-SCBL20FMV-M
Selection Chart
QD62
Mitsubishi Electric
MELSEC-Q series
high-speed counter module
QD62E
QD62D
QD62
QD 2
4-1
Connection cable
Connection cable
FA-SCBL**FMV-M
4-2
FA-TBS40P
1-14
1-14
4-2
4. Conversion Module for High-Speed Counter
Connection cable
Individual Specifications
(For MELSEC-Q Series High-Speed Counter Module)
FA-SCBL**FMV-M
Features
This cable offers a one-touch connectable connector, making it possible to reduce the wiring process time.
The cable is a shielded cable with superior noise resistance.
Related Materials
Related Products
General Specifications 7-1
Conversion Module
1-14
Specifications
Item
Model
Programmable controller-side connector
Conversion module-side connector
Cable
Conductor configuration
Cable length
Used solderless terminal
Weight
Specifications
FA-SCBL10FMV-M
FA-SCBL20FMV-M
1473381-1: Tyco Electronics AMP
D7940-7500SC, D3448-7940: Sumitomo 3M
Round 40-core cable, Cable color: Blue-gray
AWG28 (0.08mm2)
1m (39.38 inch)
2m (78.75 inch)
M4 (Daido Solderless Terminal Mfg. : RAV1.25-S4)
Approx. 160g
Approx. 260g
External Dimension
Wiring Diagram
Unit: mm (inch)
Programmable controller side
CON1
Cable length
FG
FG
View
300 (11.82)
300 (11.82)
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
With M4 round solderless terminal
CON2
(A1)
(B1)
(A2)
(B2)
(A3)
(B3)
(A4)
(B4)
(A5)
(B5)
(A6)
(B6)
(A7)
(B7)
(A8)
(B8)
(A9)
(B9)
(A10)
(B10)
(A11)
(B11)
(A12)
(B12)
(A13)
(B13)
(A14)
(B14)
(A15)
(B15)
(A16)
(B16)
(A17)
(B17)
(A18)
(B18)
(A19)
(B19)
(A20)
(B20)
47 (1.86)
CON2
With M4 round
solderless terminal
A1
B20
B1
40
(B20)
39
(A20)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
A20
2
(B1)
1
(A1)
4
External Connection
The names of signals input to the terminals of the connected, conversion module (FA-TBS40P) are as follows.
For wiring to the terminal block, see the manual of the connected high-speed counter module published by Mitsubishi Electric.
●
●
QD62
QD62E
Terminal number
Signal name
Terminal number
Signal name
●
QD62D
Terminal number
Signal name
Terminal number
Signal name
1
CH1
ΦA (12V)
2
3
5
7
9
11
13
CH1
CH1
CH1
CH1
CH1
CH1
ABCOM ΦB (12V) PRST (24V) PRST (5V) FUNC (24V) FUNC (5V)
4
6
8
10
12
14
CH1
CH1
ΦA (24V) ΦA (5V)
15
17
CH2
ΦA (12V)
16
CH2
ABCOM
18
CH1
CH1
CH1
CH1
CH1
CH2
ΦB (24V) ΦB (5V) PRST (12V) CTRLCOM FUNC (12V) ΦA (24V)
5
7
9
11
29
31
CH2
CH2
CH2
CH2
CH2
ΦB (12V) PRST (24V) PRST (5V) FUNC (24V) FUNC (5V)
20
22
24
26
28
CH1
EQU2
30
CH2
EQU2
32
CH2
CH2
CH2
CH2
CH2
CH2
ΦA (5V) ΦB (24V) ΦB (5V) PRST (12V) CTRLCOM FUNC (12V)
CH1
EQU1
CH2
EQU1
17
19
19
21
21
23
1
3
13
15
CH1
ΦA
2
CH1
ΦB
4
CH1
CH1
CH1
CH1
PRST (12V) PRSTCOM FUNC (12V) FUNCCOM
6
8
10
12
CH2
ΦA
14
CH2
ΦB
16
CH2
CH2
CH2
CH2
PRST (12V) PRSTCOM FUNC (12V) FUNCCOM
18
20
22
24
23
CH1
ΦA
CH1
ΦB
CH1
CH1
CH1
CH1
PRST (24V) PRST (5V) FUNC (24V) FUNC (5V)
CH2
ΦA
CH2
ΦB
CH2
CH2
CH2
CH2
PRST (24V) PRST (5V) FUNC (24V) FUNC (5V)
25
Conversion Module
For High-Speed Counter
View
27
25
27
NC
NC
26
28
NC
NC
29
31
CH1
EQU2
30
CH2
EQU2
32
CH1
EQU1
CH2
EQU1
33
35
37
39
NC
NC
12/24V
12/24V
34
36
38
40
NC
NC
0V
0V
33
35
37
39
NC
NC
12/24V
12/24V
34
36
38
40
NC
NC
0V
0V
Ground the shielded wire in the same manner as the programmable controller module.
When grounding is not performed and the extra wire is rolled up, the wire may act as an antenna, possibly introducing noise. Caution is required.
4-2
5. Cable for Positioning Module
Conversion Module
For DC I/O
Contents
Overview
Selection Chart
1
Interface Module For DC I/O
2
Conversion Module
For Analog I/O
3
Conversion Module
For High-Speed Counter
4
Cable For
Positioning Module
5
Conversion Module
For MELSEC-L CPU
6
Common Elements
& Appendix
7
5-Contents
Servo Amplifier Connection Cable for Positioning Module
5-1
5-1
Individual Specifications
Model List
Servo Amplifier Connection Cable for Positioning Module
Servo Amplifier Connection Cable for Positioning Module
5-1
Servo Amplifier Connection Cable for Positioning Module
5-2
7
Common Elements
& Appendix
6
Conversion Module
For MELSEC-L CPU
5
Cable For
Positioning Module
4
Conversion Module
For High-Speed Counter
3
Conversion Module
For Analog I/O
2
Interface Module For DC I/O
1
Conversion Module
For DC I/O
5. Cable for Positioning Module
5-Contents
5. Cable for Positioning Module
Overview
Servo amplifier connection cable for positioning module
(for MELSEC-Q, AnS series)
This cable is used to connect a positioning module and servo amplifier.
The cable has a branch cable with a solderless terminal for external signal
connection, making wiring work easy.
Control panel
Power
supply
Positioning module
CPU
Dedicated cable (integrated type)
External signal device
Servo
amplifier
Model List
Product
Shape
Model
Connectable modules
QD75P2/2N/4/4N
QD75D2/2N/4/4N
FA-CBLQ75G2
LD75P2/4
Discrete cable for
general-purpose stepping
motor or servo amplifier
LD75D2/4
QD75P1/1N
QD75D1/1N
FA-CBLQ75G2-1
LD75P1
Remarks
Other side of QD75 series:
Discrete cable type.
Applicable to stepping
motors manufactured by
Oriental Motor other
general-purpose servo
amplifiers, and the like.
LD75D1
Selection Chart
Cable For
Positioning Module
For general-purpose
stepping motor
or servo amplifier
5
QD75D2, QD75D2N,
QD75D4, QD75D4N,
QD75P2, QD75P2N,
QD75P4, QD75P4N,
LD75D2, LD75D4,
LD75P2, LD75P4
No pulsar cables
FA-CBLQ75G2
5-2
QD75D1, QD75D1N,
QD75P1, QD75P1N,
LD75D1, LD75P1
No pulsar cables
FA-CBLQ75G2-1
5-2
Number of cables used according to the positioning module model
Model
5-1
No. of axes
Cable model
No. of cables
QD75D1, QD75D1N, QD75P1, QD75P1N, LD75D1, LD75P1
1
FA-CBLQ75G2-1
1
QD75D2, QD75D2N, QD75P2, QD75P2N, LD75D2, LD75P2
2
FA-CBLQ75G2
1
QD75D4, QD75D4N, QD75P4, QD75P4N, LD75D4, LD75P4
4
FA-CBLQ75G2
2
Page
Cable length: 2m,
Compatible with the 2-axis product
5-2
Cable length: 2m,
Compatible with the 1-axis product
5. Cable for Positioning Module
QD75 positioning cable
Servo Amplifier Connection Cable
Individual Specifications
(discrete cable type for general-purpose stepping motor or servo amplifier)
FA-CBLQ75G2/G2-1
Specifications
Item
Model
Connected module
Compatible number of axes
Manual pulsar cable
Cable
Used solderless terminal
Discrete cable conductor configuration
Applicable solderless terminal
Weight
Features
Specifications
FA-CBLQ75G2-1
FA-CBLQ75G2
QD75D1/1N, QD75P1/1N, LD75D1, LD75P1
QD75D2/2N/4/4N, QD75P2/2N/4/4N, LD75D2/4, LD75P2/4
1
2
None
For securing area, length: 2m (78.75 inch), permissible bending radius: 120mm (4.73 inch)
V1.25-M3 (M3.5 screw round isolated solderless terminal) manufactured by J.S.T. Mfg.
Nominal cross-sectional area: 0.18mm2 (AWG25), Material: Annealed tinned copper wire
V1.25-M3 (M3.5 screw round isolated solderless terminal) manufactured by J.S.T. Mfg.
Approx. 520g
Approx. 840g
External Dimension
This cable has the discrete end(s), enabling
wiring in accordance with the connected
device.
The cable is provided with noise
countermeasures based on a shielding
process.
[FA-CBLQ75G2]
[FA-CBLQ75G2-1]
75-side connector
75-side connector
45 (1.78)
100 4)
0 (3.9
200.75)
(78
45 (1.78)
Related Materials
2000 (78.75)
General Specifications 7-1
100 (3.94)
Wiring Diagram
2000 (78.75)
100 (3.94)
Example: 5-pair (10-core)
Sheath
Shield
1
5
Note: The discrete cable end is not terminated. Be sure to terminate the wiring in accordance with the connected device.
4
Tape
3
Filler
Twisted
pair core
Wire core
(0.18mm2)
Insulator
Wire core identification
No. Insulator
Dots
Color
Core Pair Color
− (one short point) Red
1
1 Orange
−
Black
2
−
Red
3
2 Light gray
−
Black
4
−
Red
5
3
White
−
Black
6
−
Red
7
4
Yellow
−
Black
8
−
Red
9
5
Pink
−
Black
10
Cable For
Positioning Module
Cable color Dots Color
Signal name
1 Red
Orange
PG0COM
1 Black
Orange
PG024
Light gray 1 Red
PG05
Light gray 1 Black
PG0COM
White
1 Red
READY
White
1 Black
RDYCOM
Yellow
1 Red
CLEAR
Yellow
1 Black
CLRCOM
Pink
1 Red
PULSE F+/F
Pink
1 Black
PULSE F−/COM
Orange
2 Red
PULSE R+/R
2 Black
PULSE R−/COM Orange
2
5
Signal name
Cable color Dots Color
PULSE R−/COM Orange
1 Red
PULSE R+/R
Orange
1 Black
PULSE F−/COM Light gray 1 Red
Light gray 1 Black
PULSE F+/F
White
1 Red
CLRCOM
White
1 Black
CLEAR
Yellow
1 Red
RDYCOM
Yellow
1 Black
READY
Pink
1 Red
PG0COM
Pink
1 Black
PG05
Orange
2 Red
PG024
Orange
2 Black
PG0COM
Column A
Cable color Dots Color
Signal name
Orange
1 Red
PG0COM
Orange
1 Black
PG024
Light gray 1 Red
PG05
Light gray 1 Black
PG0COM
1 Red
White
READY
1 Black
White
RDYCOM
1 Red
Yellow
CLEAR
1 Black
Yellow
CLRCOM
1 Red
Pink
PULSE F+/F
1 Black
Pink
PULSE F−/COM
2 Red
Orange
PULSE R+/R
2 Black
PULSE R−/COM Orange
[FA-CBLQ75G2-1]
75-side connector
Signal name
FLS
RLS
DOG
STOP
CHG
COM
COM
PG024
PG05
PG0COM
READY
RDYCOM
CLEAR
CLRCOM
PULSE F+/F
PULSE F−/COM
PULSE R+/R
PULSE R−/COM
PULSER A+
PULSER B+
PULSER B−
PULSER A−
Column
B
Column A
Column B
0
200.75)
(78
Cable Structural Drawing
[FA-CBLQ75G2]
75-side connector
Signal name
FLS
RLS
DOG
STOP
CHG
COM
COM
PG024
PG05
PG0COM
READY
RDYCOM
CLEAR
CLRCOM
PULSE F+/F
PULSE F−/COM
PULSE R+/R
PULSE R−/COM
PULSER A+
PULSER B+
PULSER B−
PULSER A−
PULSE R−/COM
PULSE R+/R
PULSE F−/COM
PULSE F+/F
CLRCOM
CLEAR
RDYCOM
READY
PG0COM
PG05
PG024
COM
COM
CHG
STOP
DOG
RLS
FLS
Unit: mm (inch)
100 4)
(3.9
5-2
6. Conversion Module for MELSEC-L CPU
Conversion Module
For DC I/O
1
Interface Module For DC I/O
2
Conversion Module
For Analog I/O
3
Conversion Module
For High-Speed Counter
4
Cable For
Positioning Module
5
Conversion Module
For MELSEC-L CPU
6
Common Elements
& Appendix
7
6-Contents
Contents
Conversion Module Connection Cable
for MELSEC-L CPU Module with Built-in I/O Function
Built-in I/O Function (Positioning)
Signal Conversion Module
Overview
6-1
Overview
6-3
Model List
6-1
Model List
6-3
Selection Chart
6-1
Selection Chart
6-3
Individual Specifications
6-2
Individual Specifications
6-4, 5
7
Common Elements
& Appendix
6
Conversion Module
For MELSEC-L CPU
5
Cable For
Positioning Module
4
Conversion Module
For High-Speed Counter
3
Conversion Module
For Analog I/O
2
Interface Module For DC I/O
1
Conversion Module
For DC I/O
6. Conversion Module for MELSEC-L CPU
6-Contents
6. Conversion Module for MELSEC-L CPU
Overview, Model List, and Selection Chart
Overview
The following cable is used to connect between the connector of the CPU module with built-in I/O function (I/O, high-speed counter, pulse
catch, positioning, interrupt input) and a FA goods conversion module.
L02CPU/L02SCPU/L26CPU
L02CPU-P/L26CPU-PBT
High-speed counter
FA-SCBL**FMV-M
Encoder
2
40
General-purpose
screw terminal block
FA-TBS40P
1-phase
2-phase
Positioning
General-purpose output
Display lamp
General-purpose input
Connector
Interrupt input
Switch
Servo amplifier, driver
Pulse catch
Command pulse
Sensor
Command pulse
Model List
Module-to-module cable
Product
Shape
Model
Remarks
FA-SCBL10FMV-M
1m
(39.38 inch)
FA-SCBL20FMV-M
2m
(78.75 inch)
For CPU module
(built-in I/O function)
Conversion Module
For MELSEC-L CPU
• This cable is used to connect between the connector of the CPU module with
built-in I/O function (positioning function, high-speed counter function, pulse catch
function, interrupt input function, general-purpose input/output function) and
FA-TBS40P.
Selection Chart
6
Programmable controller module model
Conversion module model
Connection cable
L02CPU
L02CPU-SET
L02CPU-P
L02CPU-P-SET
L02SCPU
L26CPU
L26CPU-SET
L26CPU-BT
L26CPU-BT-SET
L26CPU-PBT
L26CPU-PBT-SET
6-1
FA-TBS40P
1-14
FA-SCBL**FMV-M
6-2
Page
6-2
6. Conversion Module for MELSEC-L CPU
Individual Specifications
Individual Specifications
Conversion module connection cable for MELSEC-L CPU module with built-in I/O function
FA-SCBL**FMV-M
Features
This cable connects between the connector of the MELSEC-L series CPU module with built-in I/O function and a
general-purpose 40-point conversion module.
Related Materials
Related Products
General Specifications 7-1
Conversion Module
1-14
Specifications
Item
Model
Programmable controller side connector
Conversion module side connector
Cable
Conductor configuration
Cable length
Used solderless terminal
Weight
Specifications
FA-SCBL10FMV-M
FA-SCBL20FMV-M
1473381-1: Tyco Electronics AMP
D7940-7500SC, D3448-7940: Sumitomo 3M
Round 40-core cable, Cable color: Blue-gray
AWG28 (0.08mm2)
1m (39.38 inch)
2m (78.75 inch)
M4 (Daido Solderless Terminal Mfg.: RAV1.25-S4)
Approx. 160g
Approx. 260g
External Dimension
Wiring Diagram
Unit: mm (inch)
Programmable controller side
CON1
Cable length
FG
FG
View
300 (11.82)
300 (11.82)
CON1
B20
A20
B19
A19
B18
A18
B17
A17
B16
A16
B15
A15
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
With M4 round solderless terminal
CON2
(A1)
(B1)
(A2)
(B2)
(A3)
(B3)
(A4)
(B4)
(A5)
(B5)
(A6)
(B6)
(A7)
(B7)
(A8)
(B8)
(A9)
(B9)
(A10)
(B10)
(A11)
(B11)
(A12)
(B12)
(A13)
(B13)
(A14)
(B14)
(A15)
(B15)
(A16)
(B16)
(A17)
(B17)
(A18)
(B18)
(A19)
(B19)
(A20)
(B20)
47 (1.86)
CON2
With M4 round
solderless terminal
View
A1
B20
B1
40
(B20)
39
(A20)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
A20
2
(B1)
1
(A1)
External Connection
The names of signals input to the terminals of the connected conversion module (FA-TBS40P) are as follows.
For wiring to the terminal block, see the manual of the connected MELSEC-L CPU module published by Mitsubishi Electric.
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
Terminal number
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
Signal name
IN0
24V
IN0
DIFF
IN0
COM
IN1
24V
IN1
DIFF
IN1
COM
IN4
24V
IN4
DIFF
IN4
COM
IN
COM
IN6
IN8
INA
INC
INE
OUT0
OUT2
OUT4
OUT6
OUT
COM
Programmable controller
connector pin number
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
Terminal number
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
Signal name
IN2
24V
IN2
DIFF
IN2
COM
IN3
24V
IN3
DIFF
IN3
COM
IN5
24V
IN5
DIFF
IN5
COM
IN
COM
IN7
IN9
INB
IND
INF
OUT1
OUT3
OUT5
OUT7
OUT
COM
Ground the shielded wire in the same manner as the programmable controller module.
When grounding is not performed and the extra wire is rolled up, the wire may act as an antenna, possibly introducing noise. Caution is required.
Connection example 1: With high-speed counter function
Terminal number
Signal name
Terminal number
Signal name
1
3
5
7
9
11
13
15
17
PULSE A1 PULSE A1 PULSE A1 PULSE B1 PULSE B1 PULSE B1 PULSE Z1 PULSE Z1 PULSE Z1
24V
D FF
COM
24V
DIFF
COM
24V
DIFF
COM
2
4
6
8
10
12
14
16
18
PULSE A2 PULSE A2 PULSE A2 PULSE B2 PULSE B2 PULSE B2 PULSE Z2 PULSE Z2 PULSE Z2
24V
D FF
COM
24V
DIFF
COM
24V
DIFF
COM
19
IN
COM
20
IN
COM
21
23
FUNC1 LATCH1
22
24
FUNC2 LATCH2
25
27
29
31
33
35
37
39
NC
NC
NC
CH1
EQU1
CH1
EQU2
NC
NC
OUT
COM
26
28
30
32
34
36
38
40
NC
NC
NC
CH2
EQU1
CH2
EQU2
NC
NC
OUT
COM
35
37
Conversion Module
For MELSEC-L CPU
B20
6
Programmable controller
connector pin number
Connection example 2: With positioning function
Terminal number
1
3
5
7
9
11
13
15
17
19
Signal name
NC
NC
NC
NC
NC
NC
PG01
24V
PG01
DIFF
PG01
COM
IN
COM
Terminal number
2
4
6
8
10
12
14
16
18
20
Signal name
NC
NC
NC
NC
NC
NC
PG02
24V
PG02
DIFF
PG02
COM
IN
COM
21
23
25
CHG 1 READY 1 DOG 1
22
24
26
CHG 2 READY 2 DOG 2
27
29
31
33
FLS 1
RLS 1
NC
CLEAR1
28
30
32
34
FLS 2
RLS 2
NC
CLEAR2
PULSE PULSE
F1
R1
36
38
PULSE PULSE
F2
R2
39
OUT
COM
40
OUT
COM
Connection example 3: With 24VDC I/O, high-speed counter, and positioning function combination
Terminal number
Signal name
1
3
5
7
9
11
13
15
17
PULSE A1 PULSE A1 PULSE A1 PULSE B1 PULSE B1 PULSE B1 PULSE Z1 PULSE Z1 PULSE Z1
24V
D FF
COM
24V
DIFF
COM
24V
DIFF
COM
19
IN
COM
Terminal number
2
4
6
8
10
12
14
16
18
20
Signal name
X2
NC
X2
COM
X3
NC
X3
COM
PG02
24V
PG02
DIFF
PG02
COM
IN
COM
21
23
FUNC1 LATCH1
22
24
25
27
29
31
33
35
37
39
XA
XC
XE
CH1
EQU1
CH1
EQU2
Y4
Y6
OUT
COM
36
38
26
CHG 2 READY 2 DOG 2
28
30
32
34
FLS 2
RLS 2
Y1
CLEAR2
PULSE PULSE
F2
R2
40
OUT
COM
*Do not perform wiring to any signal name indicated as NC.
6-2
6. Conversion Module for MELSEC-L CPU
Overview, Model List, and Selection Chart
Overview
This module is used to convert the pulse output of the CPU module with built-in I/O function (positioning) from the open collector output to the
differential driver output.
* The following shows an example of Mitsubishi Electric servo amplifier use. The same is
applicable to the servo amplifiers of other companies.
R
U S
User wiring
PU S
OM
N
FA-PT1LBD
L02CPU/L02SCPU/L26CPU
L02CPU-P/L26CPU-PBT
D
OM
PG
D
G
HG
OG
S
R S
R A Y
N
OM
C
AR
COM
U S
M T UB SH
MR B50
Mitsubishi Electric
general-purpose servo amplifier
Relay terminal block
MR-TB50
(Mitsubishi Electric
general-purpose
Relay terminal block cable length: 1m
servo option)
MR-J2M-CN1TBL1M
(Mitsubishi Electric general-purpose servo option)
PW
V
V
V
N
General-purpose
stepping motor
General-purpose
servo amplifier
Positioning signal
conversion module
FA-PT1LBD
R
PU S
User wiring
R S
R
DY
N
C M
C
R
OM
U S
U S
M TSUB SH
MR TB 0
C M
N
FA PT1LBD
D
C M
G
D
PG
C G
DOG
S
Connection cable
for positioning signal
conversion module
FA-SCBL10FM2LV-LB
Mitsubishi Electric
general-purpose servo amplifier
Relay terminal block
MR-TB50
(Mitsubishi Electric
general-purpose
Relay terminal block cable length: 1m
servo option)
MR-J2M-CN1TBL1M
(Mitsubishi Electric general-purpose servo option)
PW
V
V
V
N
General-purpose
stepping motor
General-purpose
servo amplifier
Positioning signal
conversion module
FA-PT1LBD
Or
18
19
17
16
20
19
20
Switches, etc.
4
3
2
1
2
FALTB20P1
5
6
7
8
9
10
11
12
13
14
15
User wiring
20P connector ↔ Screw terminal block type
conversion module
FA-LTB20P
Model List
Product
Shape
Model
Remarks
Conversion Module
For MELSEC-L CPU
Positioning signal conversion
module
FA-PT1LBD
●For CPU module with built-in I/O function
●Applicable to both sink output and source output types
6-4
Connection cable for positioning
signal conversion module
FA-SCBL10FM2LV-LB
●Cable length: 1m
6-5
20-point terminal block type
conversion module
FA-LTB20P
●Allows you to combine the positioning (differential driver output) module and the general-purpose
I/O terminal module in accordance with the system.
6-5
6
Selection Chart
Programmable controller module model
Conversion module model
Connection cable
L02CPU
L02CPU-SET
L02CPU-P
L02CPU-P-SET
L02SCPU
L26CPU
L26CPU-SET
L26CPU-BT
L26CPU-BT-SET
L26CPU-PBT
L26CPU-PBT-SET
6-3
Page
FA-PT1LBD
14-4
FA-SCBL10FM2LV-LB
14-4
6. Conversion Module for MELSEC-L CPU
Individual Specifications
Individual Specifications
Positioning signal conversion module
FA-PT1LBD
Features
This module converts the output to the differential driver output, improving exogenous noise resistance.
The module converts the output to the differential driver output, offering a drive module wiring length of 10m, improving
module installation freedom.
Applicable Standards
Related Materials
UL
General Specifications 7-1
Specifications
N1
OM
P 0
D F
G0
V
HG
G0
OM
FS
DOG
O T
OM1
R A Y
N
C M
RS
UT
OM
P L E
F
U SE
F+
CE R
7.5 (0.3)
16.5 (0.65)
50 (1.97)
I 1
D F
N1
4V
U SE
R
P L E
R+
U SE
C M
4
(0.16)
2.0µs or more
DIN rail center
40 (1.57)
Terminal block layout
10m
IN0
24V
24V
24V±10%, 50mA or less
0V
According to the MELSEC-L series CPU with built-in I/O function
(positioning function)
IN1
DIFF
IN1
COM
IN1
24V
PG0
DIFF
PG0
24V
CHG
PG0
COM
FLS
DOG
READY
RLS
OUT
COM1
OUT PULSE PULSE
COM
F
R
IN
PULSE PULSE PULSE
CLEAR
COM
F+
R+
COM
0.5 to 1.25mm2, 58.8 to 88.2N cm (5.21 to 7.81lbf in)
●
Between power supply and signal: 500VAC for 1 minute, 10MΩ or more
Withstand voltage, insulation resistance
M4 × 0.7mm × 16mm or more, tightening torque: 78 to 108Ncm (6.95 to 10.41bf in)
Screw installation
Module
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compatible)
DIN rail installation
installation
Approx. 170g
Weight
Note: For wiring to the terminal, see the manual of the connected MELSEC-L CPU module published by Mitsubishi Electric.
IN0-24V
IN0-DIFF
IN0-COM
IN1-24V
IN1-DIFF
IN1-COM
IN4-24V
IN4-DIFF
IN4-COM
IN6
INA
INC
INE
IN8
IN-COM
OUT2
OUTCOM
OUT4
OUT6
Wiring Diagram
24VDC ±10% (within 5% ripple rate)
At 24VDC, approx. 40mA
*Not including current consumption of programmable controller
M3 screw, number of terminals: 25P, 7.62-mm (0.3-inch) pitch,
spring enhanced screw with finger protection cover
Internal
power
supply
Signal conversion
PG0-DIFF
PG0-COM
CHG
DOG
FLS
RLS
READY
IN-COM(READY-COM)
OUT-COM1
CLEAR
OUT-COM(CLEAR-COM)
PULSE F+
PULSE FPULSE R+
PULSE RPULSE COM
PG0-24V
IN1-DIFF
IN1-COM
●
IN0-COM
External
input signal
Drive module
Conversion Module
For MELSEC-L CPU
Encoder
feedback pulse output
(Open collector or
differential driver)
6
●
IN0
COM
IN0
DIFF
IN1-24V
Applicable wire,
tightening torque
N0
OM
I 0
D F
IN0-DIFF
Terminal screw
Terminal block
0
2V
V
2.0µs or more
2.0µs or more
Unit: mm (inch)
7.9 (0.31)
4.5 (0.18)
17.6 (0.7)
FA PT1LBD
2V
Connector
Module current consumption
PW
200kpps
24V
Maximum connection
distance with drive module
Command pulse signal power supply
PG0, CHG, DOG, FLS, RLS input
specifications
Ready input specifications
Clear output specifications
Module power supply
118 (4.65)
109 +10 (4.29)
2-Φ4.5 × 5.1 installation hole
(M4 installation screw)
4.5 (0.18)
IN0-24V
Number of converted axes
Output
Maximum number of
output pulses
PULSE F/R
output
Pulse width
specifications
External Dimension
Specifications
L02CPU, L02SCPU, L26CPU
L02CPU-P, L26CPU-PBT
(Sink output type)
(Source output type)
1
AM26C31 equivalent differential driver
0V
Connected programmable controller
CE
Terminal block
Item
cUL
6-4
6. Conversion Module for MELSEC-L CPU
Individual Specifications
Positioning signal conversion module connection cables
FA-SCBL10FM2LV-LB
Features
This cable offers a one-touch connectable connector, making it possible to reduce wiring process time.
The cable used is a shielded cable with superior noise resistance.
Related Materials
Related Products
General Specifications 7-1
Conversion Module
Specifications
Wiring Diagram
Item
Specifications
FCN367J040-AU/MW: Fujitsu Component
D7920-B500FL, D3448-7920 × 20: Sumitomo 3M
Round 20-core cable × 2, Cable color: Gray
AWG28 (0.08mm2)
1m (39.38 inch)
M4 (Daido Solderless Terminal Mfg.: RAV1.25-S4)
Approx. 150g
Programmable controller side connector
Conversion module side connector
Cable
Conductor configuration
Cable length
Used solderless terminal
Weight
Programmable controller
connection side
PHASE1
View
A1
B20
B1
Unit: mm (inch)
Conversion module
connection side
1000 (39.37)
PHASE1
2LV LB
10FM
CON1
BL
FA SC
PHASE2
TOP VIEW
PHASE2
19
2
1
TOP VIEW
FG
Vie
w
300 (11.81)
20
MIL 20P
PHASE2 (Axis 2 side)
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
FCN 40P
CON1
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
MIL 20P
PHASE1(Axis 1 side)
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
FCN 40P
CON1
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
External Dimension
A20
6-5
General-purpose 20-point terminal block type conversion module
FA-LTB20P
Features
This module makes it possible to combine positioning (differential driver output) and general-purpose input/output terminal
blocks in accordance with your system.
When the same modules are installed in a row on a DIN rail, there is no need to provide space below adjacent modules
for screw mount insertion.
The printed-circuit board is an
Related Materials
inexpensive open type that can
General Specifications 7-1
M3 7.62-mm (0.3-inch) Applicable Solderless Terminal 7-2
be viewed from the outside. The
module can be installed on a
DIN rail or with screws.
External Dimension
6
−
Terminal screw
M3 screws, number of terminals: 20P, 7.62-mm (0.3-inch) pitch, regular screw
Terminal block
Applicable wire,
0.3 to 2mm2 (with solderless terminal use), 50 to 75Ncm (4.52 to 6.59lbf in)
tightening torque
Screw installation M4 × 0.7mm × 10mm or more, tightening torque: 78 to 118N cm (6.95 to 10.41lbf in)
Module installation
DIN rail
Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC60715 compliant)
Withstand voltage,
500VAC for 1 minute, 10MΩ or more
insulation resistance
(between all DC external terminals ↔ ground, between charged areas)
Weight
Approx. 115g
Precautions
Failure to push in the module connector until it is locked may cause poor contact.
4
7
6
8
11
10
13
12
15
14
17
16
19
18
20
7.62 (0.30)
19
20
17
18
15
16
13
14
11
12
9
10
7
8
5
6
3
4
14.3 (0.57)
●
5.5 (0.22)
Marking strip
1
3
2
5
4
7
6
9
8
11
0
13
12
15
14
17
16
19
18
20
Module Installation Tips
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
TB1
(20P)
9
35 (1.38)
19
5
●
●
4.5 (0.18)
20
1
7.5 (0.30)
2
18 (0.71)
2
3
k
loc
ple °)
Sim (120
1
48VDC, 1A/point
External Dimension
6-5
FALTB20P
29 (1.15)
Specifications
FA-LTB20P
20 points, general-purpose
4 (0.16)
Conversion Module
For MELSEC-L CPU
Item
Model
No. of points
Maximum operating
voltage, current
Common method
44.7 (1.76)
47 (1.86)
Specifications
CON1
(20P)
Unit: mm (inch)
2-Φ4.5×5.1 long installation holes
115 (4.53)
105 (4.14)
93 (3.67)
When installing models that have screw
installation holes on both module sides adjacent
to each other on a DIN rail, the models can be
installed close together as shown below.
1
1
2
2
Applicable models
●FA-LTB**
6
Conversion Module
For MELSEC-L CPU
6. Conversion Module for MELSEC-L CPU
6-6
7. Common Elements & Appendix
Conversion Module
For DC I/O
Contents
Common Elements
Appendix
1
Interface Module For DC I/O
2
Conversion Module
For Analog I/O
3
Conversion Module
For High-Speed Counter
4
Cable For
Positioning Module
5
Conversion Module
For MELSEC-L CPU
6
Common Elements
& Appendix
7
7-Contents
General Specifications
7-1
Model: Alphabetical Index
7-4
M3 Screw 7-mm (0.28-inch) Pitch Applicable Solderless Terminal
7-2
Warranty
7-5
M3 Screw 7.62-mm (0.3-inch) Pitch Applicable Solderless Terminal
7-2
Safety Precaution
Explanation of Connection Method
7-3
Related Catalog
7-6, 7
7-8
7
Common Elements
& Appendix
6
Conversion Module
For MELSEC-L CPU
5
Cable For
Positioning Module
4
Conversion Module
For High-Speed Counter
3
Conversion Module
For Analog I/O
2
Interface Module For DC I/O
1
Conversion Module
For DC I/O
7. Common Elements & Appendix
7-Contents
7. Common Elements & Appendix
General Specifications
General Specifications
The following describes the general specifications.
MELSEC-Q/L series system
Item
Specifications
Operating ambient temperature
0 to 55°C
Storage ambient temperature
-25 to 75°C
Operating ambient humidity
5 to 95%RH (no condensation)
Storage ambient humidity
Vibration
resistance
5 to 95%RH (no condensation)
10 to 57Hz
With intermittent vibration
With continual vibration
Acceleration: 9.8m/s2
10 to 57Hz
Half amplitude: 0.035mm
57 to 150Hz
Number of sweeps
Acceleration: 4.9m/s2
10 times in each direction X, Y, and Z
Applicable standards
Shock resistance
Half amplitude: 0.075mm
57 to 150Hz
IEC61131-2
147m/s2, 3 times in each direction X, Y, and Z
Applicable standards
Operating atmosphere
IEC61131-2
Free of corrosive gases
Operating altitude *1
2000m or less
Installation location
Inside control panel
Overvoltage category *2
II or less
Pollution degree *3
2 or less
*1: Do not store or use the module under a pressure higher than the atmospheric pressure of altitude 0m.
*2: This indicates the section of power supply to which the equipment is assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
*3: This index indicates the degree to which conductive material is generated in the environment where the device is used.
MELSEC-AnS series system
Item
Specifications
Operating ambient temperature
0 to 55°C
Storage ambient temperature
-20 to 75°C
Operating ambient humidity
10 to 90%RH (no condensation)
Storage ambient humidity
With intermittent vibration
Vibration
resistance
10 to 90%RH (no condensation)
10 to 57Hz
With continual vibration
Acceleration: 9.8m/s2
10 to 57Hz
Half amplitude: 0.035mm
57 to 150Hz
Number of sweeps
Applicable standards
Shock resistance
Operating atmosphere
Half amplitude: 0.075mm
57 to 150Hz
Acceleration: 4.9m/s2
10 times in each direction X, Y, and Z
IEC61131-2
147m/s2, 3 times in each direction X, Y, and Z
Applicable standards
IEC61131-2
Free of corrosive gases
Operating altitude *1
2000m or less
Installation location
Inside control panel
Overvoltage category *2
II or less
Pollution degree *3
2 or less
*1: Do not store or use the module under a pressure higher than the atmospheric pressure of altitude 0m.
*2: This indicates the section of power supply to which the equipment is assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
*3: This index indicates the degree to which conductive material is generated in the environment where the device is used.
Common Elements
& Appendix
7
7-1
7. Common Elements & Appendix
M3/3.5 Screw Applicable Solderless Terminals
M3 Screw 7-mm (0.28-inch) pitch applicable solderless terminal
Bare solderless
terminal
0.3 to
R1.25-3N
1.25mm2
R1.25-3.5N
Solderless terminal
with insulation
TMEV1.25Y-3
TMEV1.25Y-3K
TMEV1.25-3
Nichifu
NTM
●Solderless terminal dimensions
Y-shaped
Solderless terminal
with insulation
TMEV1.25-3N
1.25Y-3
TMEV1.25Y-3.5
TMEV1.25-3.5N
1.25Y-3N
TMEV1.25Y-3.5K
TG NV1.25-3N
1.25Y-3.5
TG NV 1.25Y-3
TG NV 1.25Y-3.5
1.25-B3A
0.3 to 1.25mm2
V1.25-B3A
1.25-C3A
V1.25-MS3
1.25-MS3
Nippon Tanshi
NTK
0.3 to 1.25mm2
R1.25-3ML
RAV1.25-3ML
VD1.25-3L
VDAV1.25-3L
R1.25-3.5SL
RAP1.25-3ML
VD1.25-3.5SS
VDAV1.25-3.5SS
MIN4.0 (0.16) MIN
Φ3.2
Y-shaped
bare solderless terminal
Y-shaped solderless terminal
with insulation
MIN4.0 (0.16)
1.25-C3.5A
Round solderless terminal
with insulation
MIN4.0 (0.16) MIN
Φ3.2
TG NV 1.25Y-3N
TG NV1.25-3.5N
J.S.T. Mfg.
JST
Round
bare solderless terminal
MIN4.0 (0 16)
MAX4.7
(0.19)
MAX4.7
(0.19)
●Terminal block dimensions
Unit: mm (inch)
MAX
5.8
(0.23)
Bare solderless
terminal
MAX
5.8
(0.23)
Manufacturer
Round-shaped
Applicable
wire size
MIN
3.2
MAX (0.13)
5.8
(0.23)
Type
MIN
3.2
(0.13)
MAX
5.8
(0.23)
●Recommended solderless terminals
Unit: mm (inch)
0.95
(0.04)
6.05
(0.24)
7.95
(0.31)
6 4.7
(0.24) (0.19)
7.0
(0.27)
0.95
(0.04)
M3 Screw 7.62-mm (0.3-inch) pitch applicable solderless terminal
●Recommended solderless terminals
The M3 screw terminal block used with FA goods has an applicable wire size of 0.5 to 1.25mm2,
but is connectable to 0.3 to 2mm2 wires with use of a solderless terminal.
1.25 to 2.0mm2
R1.25-3N
TG 1.25-3N
1.25Y-3N
TG 1.25Y-3N
R1.25-3.5N
TGNV 1.25-3.5N
1.25Y-3L (Note 1)
TGNV 1.25Y-3L (Note 1)
V
TGN 2-3N
R2-3N
0.3 to 1.25mm2
V1.25-MS3
1.25-MS3
1.25Y-3.5
TG 1.25Y-3.5
2Y-3
TGNV 2Y-3
2Y-3.5S
TGNV 2Y-3.5S
1.25-C3A
V1.25-B3A
1.25-N3A (Note 1)
V1.25-N3A (Note 1)
1.25-C3.5A
0.3 to 1.25mm2
Nippon Tanshi
NTK
1.25 to 2.0mm2
2-N3A
V2-MS3
2-MS3
R1.25-3ML
RAV1.25-3ML
R1.25-3.5SL
RAP1.25-3ML
RAV2-3SL
R2-3SL
RAP2-3SL
VD1.25-3L
VDAV1.25-3L
VD1.25-3.5SS
VDAV1.25-3.5SS
VD1.25-3.5S (Note 1)
VDAV1.25-3.5S (Note 1)
VD2-3S
VDAV2-3.5SS
VD2-3.5SS
VD2-3.5S (Note 1)
VDAV2-3.5S (Note 1)
Note 1: This solderless terminal is recommended for spring-up screws only. Do not apply the terminal to regular screws.
●Terminal block dimensions
MIN
Φ3.2
MIN
Φ3.2
A
Y-shaped
Y-shaped solderless terminal
bare solderless terminal
with insulation
A
V2-N3A
2-M3A (Note 1)
Round solderless terminal
with insulation
A
B
1.25 to 2.0mm2
A
V
N
1.25-B3A
MAX3.5
(0.14)
MAX3.5
(0.14)
Solderless terminal dimensions
A
B
Spring-up screw
MIN 5.0(0.20)
MAX 6.3(0.25)
Regular screw
MIN 5.5(0.22)
MAX 6.1(0.24)
Unit: mm (inch)
Spring-up screw
Regular screw
1.42
(0.06)
6.2
(0.24)
9.04
(0.36)
1.42
(0.06)
Common Elements
& Appendix
1.22
(0.05)
5.5 4
5 5.7
6.4
(0.25)
8.84
(0.35)
(0.20) (0.22)
1.22
(0.05)
(0.22) (0.16)
7.62
(0.30)
7.62
(0.30)
7
J.S.T. Mfg.
JST
Round
bare solderless terminal
B
0.3 to 1.25mm2
V
N
B
Nichifu
NTM
Solderless terminal
with insulation
TGNV 1.25Y-3
1.25Y-3
V
N
●Solderless terminal dimensions Unit: mm (inch)
Y-shaped
Bare solderless
terminal
B
Bare solderless Solderless terminal
terminal
with insulation
MIN
3.2
(0.13)
Round-shaped
Applicable
wire size
MIN
3.2
(0.13)
Type
Manufacturer
7-2
7. Common Elements & Appendix
Explanation of Connection Methods
Explanation of Connection Method
1-wire to 3-wire types
1) When connecting input using a 1-wire type
A 1-wire type indicates that only one wire from a limit switch, etc., can be connected to the conversion module.
Separate common terminals are required.
0
2
4
1
6
3
8
5
A
7
9
C
B
E
D
10
F
12
11
14
13
16
15
18
17
1A
19
1C
1B
1E 24V
1D
1F
Limit switch
FA-TB32XY terminal block
0V
+
24VDC power supply
-
COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM
General-purpose terminal block
for common wiring
2) When connecting input using a 2-wire type
A 2-wire type indicates one or two wires from a limit switch, etc., can be connected to the conversion module.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
24V
FA-TB16XY1 terminal block
0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V
Limit switch
+
24VDC power supply
-
3) When connecting input using a 3-wire type
A 3-wire type indicates that up to three wires from sensors, etc., can be connected to the conversion module.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
24V
FA-TB16XY1 terminal block
0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V
+
24VDC power supply
Sensor
Internal
circuit
-
nternal
circuit
4) When connecting output using a 1-wire type
A 1-wire type indicates that only one wire from a load can be connected to the conversion module.
0
2
3
6
5
8
7
A
9
C
B
E
D
10
F
12
11
14
13
16
15
18
17
1A
19
1C
1B
1E 24V
1D
1F
FA-TB32XY terminal block
0V
-
Load
Load
1
4
24VDC power supply
+
COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM
General-purpose terminal block
for common wiring
5) When connecting output using a 2-wire type
0
1
2
0V 24V
3
4
5
6
7
8
9
A
B
C
D
E
F
24V
0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V
FA-TB16XY1 terminal block
7
Load
+
Load
Common Elements
& Appendix
7-3
A 2-wire type indicates that one or two wires from a load, etc., can be connected to the conversion module.
24VDC power supply
-
7. Common Elements & Appendix
Model: Alphabetical Index
Model: Alphabetical Index
Product name
MIL 40P connector covers for distributed module (10 covers included)
Connection cable for DC-dedicated distributed type conversion modules, 0.5m (19.69 inch)
DC-dedicated 32-point conversion module connection cable (for negative common input modules), 1m (39.38 inch)
DC-dedicated 32-point conversion module connection cable (for source output modules), 1m (39.38 inch)
Interface module connection cable (for CC-Link remote I/O), 1m (39.83 inch)
Interface module connection cable (for sink-type I/O modules), 1m (39.83 inch)
DC-dedicated 32-point conversion module connection cable (for CC-Link remote I/O modules), 1m (39.38 inch)
DC-dedicated 32-point conversion module connection cable (for sink-type I/O modules), 1m (39.38 inch)
DC-dedicated 32-point conversion module connection cable (for FCN connector source I/O modules), 1m (39.38 inch)
DC-dedicated 40-point type conversion module connection cable (for Mitsubishi Electric programmable controller I/O modules), 1m (39.38 inch)
Connection cable for DC-dedicated distributed type conversion modules, 1m (39.38 inch)
DC-dedicated 32-point conversion module connection cable (for negative common input modules), 2m (78.75 inch)
DC-dedicated 32-point conversion module connection cable (for source output modules), 2m (78.75 inch)
Interface module connection cable (for CC-Link remote I/O), 2m (78.75 inch)
Interface module connection cable (for sink-type I/O modules), 2m (78.75 inch)
DC-dedicated 32-point conversion module connection cable (for CC-Link remote I/O modules), 2m (78.75 inch)
DC-dedicated 32-point conversion module connection cable (for sink-type I/O modules), 2m (78.75 inch)
DC-dedicated 32-point conversion module connection cable (for FCN connector source type I/O modules), 2m (78.75 inch)
DC-dedicated 40-point type conversion module connection cable (for Mitsubishi Electric programmable controller I/O), 2m (78.75 inch)
Discrete cable for programmable controller I/O modules (FCN 40P, AWG28), 2m (78.75 inch)
Connection cable for DC-dedicated distributed type conversion modules, 2m (78.75 inch)
Conversion module connection cable for analog module (Q66AD-DG), 2m (78.75 inch)
Conversion module connection cable for analog module (Q66DA-G), 2m (78.75 inch)
Conversion module connection cable for analog module (Q68AD-G), 2m (78.75 inch)
Conversion module connection cable for isolated RTD input module (Q68RD3-G), 2m (78.75 inch)
Conversion module connection cable for thermocouple input module (Q68TD-G-H01/02), 2m (78.75 inch)
Interface module connection cable (for CC-Link remote I/O), 3m (118.12 inch)
Interface module connection cable (for sink-type I/O modules), 3m (118.12 inch)
DC-dedicated 32-point conversion module connection cable (for CC-Link remote I/O modules), 3m (118.12 inch)
DC-dedicated 32-point conversion module connection cable (for sink-type I/O modules), 3m (118.12 inch)
DC-dedicated 32-point conversion module connection cable (for FCN connector source type I/O modules), 3m (118.12 inch)
DC-dedicated 40-point type conversion module connection cable (for Mitsubishi Electric programmable controller I/O modules), 3m (118.12 inch)
Discrete cable for programmable controller I/O (FCN 40P, AWG28), 3m (118.12 inch)
Conversion module connection cable for analog module (Q66AD-DG), 3m (118.12 inch)
Conversion module connection cable for analog module (Q66DA-G), 3m (118.12 inch)
Conversion module connection cable for analog module (Q68AD-G), 3m (118.12 inch)
Conversion module connection cable for isolated RTD input module (Q68RD3-G), 3m (118.12 inch)
Conversion module connection cable for thermocouple input module (Q68TD-G-H01/02), 3m (118.12 inch)
DC-dedicated 32-point conversion module connection cable (for negative common input modules), 5m (196.86 inch)
DC-dedicated 32-point conversion module connection cable (for source output modules), 5m (196.86 inch)
Interface module connection cable (for sink-type I/O modules), 5m (196.86 inch)
DC-dedicated 32-point conversion module connection cable (for sink-type I/O modules), 5m (196.86 inch)
Discrete cable for programmable controller I/O module (FCN 40P, AWG28), 5m (196.86 inch)
Connection cable for DC-dedicated distributed type conversion modules, 5m (196.86 inch)
Positioning module cable for general-purpose stepping motor or servo amplifier (MELSEC-Q series, discrete cable), 2m (78.75 inch)
Positioning module cable for general-purpose stepping motor or servo amplifier (MELSEC-Q series, discrete cable), 2m (78.75 inch)
DC-dedicated 20-point connector terminal block conversion module
Conversion module for analog module (Q66AD-DG)
Conversion module for analog module (Q68AD-G)
Conversion module for analog module (Q66DA-G)
Conversion module for isolated RTD input module (Q68RD3-G)
Conversion module for thermocouple input module (Q68TD-G-H01/02)
Interface module NO contact relay replacement (4 included)
Signal conversion module for MELSEC-L CPU module with built-in I/O function (positioning)
Positioning signal conversion module connection cable, 1m (39.38 inch)
Connection cable for high-speed counter or MELSEC-L CPU module with built-in I/O function, 1m (39.38 inch)
Connection cable for high-speed counter or MELSEC-L CPU module with built-in I/O function, 2m (78.75 inch)
DC-dedicated, 16-point, connector ↔ terminal block conversion module (1-wire type)
DC-dedicated, 16-point distributed-type, connector ↔ terminal block conversion module (3-wire type, 0 to F)
DC-dedicated, 16-point distributed-type, connector ↔ terminal block conversion module (3-wire type, 10 to 1F)
DC-dedicated, 32-point, connector ↔ terminal block conversion module (1-wire type)
DC-dedicated, 32-point, connector ↔ terminal block conversion module (1-wire type, with LED display, source type)
DC-dedicated, 32-point, connector ↔ terminal block conversion module (1-wire type, with LED display, sink type)
DC-dedicated, 32-point small-size type, connector ↔ terminal block conversion module (1-wire type)
DC-dedicated, 40-point small-size type, connector ↔ terminal block conversion module
DC-dedicated, 32-point, connector ↔ spring clamp terminal block conversion module (1-wire type)
Interface module (M3 screw compatible, 16-point, NO contact relay 24VDC input, independent common, with socket)
Interface module (M3 screw compatible, 16-point, NO contact relay output, 1-wire type, with socket)
Interface module (M3 screw compatible, 16-point, NO contact relay output, independent common, with socket)
Page
1-14
1-20
1-19
1-19
1-21, 2-16
1-18, 2-16
1-20
1-17
1-18
1-21
1-20
1-19
1-19
1-21, 2-16
1-18, 2-16
1-20
1-17
1-18
1-21
1-17
1-20
3-5
3-5
3-5
3-7
3-6
1-21, 2-16
1-18, 2-16
1-20
1-17
1-18
1-21
1-17
3-5
3-5
3-5
3-7
3-6
1-19
1-19
1-18, 2-16
1-17
1-17
1-20
5-2
5-2
6-5
3-5
3-5
3-5
3-7
3-6
2-17
6-4
6-5
4-2, 6-2
4-2, 6-2
1-11
1-13
1-13
1-11
1-12
1-12
1-12
1-14
1-15
2-13
2-14
2-15
Common Elements
& Appendix
Model
FA-CAP40MIL10
FA-CBL05MMH
FA-CBL10DMFX
FA-CBL10DMFY
FA-CBL10FM2H
FA-CBL10FM2V
FA-CBL10FMH
FA-CBL10FMV
FA-CBL10FMVE
FA-CBL10FMV-M
FA-CBL10MMH
FA-CBL20DMFX
FA-CBL20DMFY
FA-CBL20FM2H
FA-CBL20FM2V
FA-CBL20FMH
FA-CBL20FMV
FA-CBL20FMVE
FA-CBL20FMV-M
FA-CBL20FV
FA-CBL20MMH
FA-CBL20Q66ADDG
FA-CBL20Q66DAG
FA-CBL20Q68ADGN
FA-CBL20Q68RD3G
FA-CBL20Q68TDG
FA-CBL30FM2H
FA-CBL30FM2V
FA-CBL30FMH
FA-CBL30FMV
FA-CBL30FMVE
FA-CBL30FMV-M
FA-CBL30FV
FA-CBL30Q66ADDG
FA-CBL30Q66DAG
FA-CBL30Q68ADGN
FA-CBL30Q68RD3G
FA-CBL30Q68TDG
FA-CBL50DMFX
FA-CBL50DMFY
FA-CBL50FM2V
FA-CBL50FMV
FA-CBL50FV
FA-CBL50MMH
FA-CBLQ75G2
FA-CBLQ75G2-1
FA-LTB20P
FA-LTB40ADDG
FA-LTB40ADGN
FA-LTB40DAG
FA-LTB40RD3G
FA-LTB40TDG
FA-NYP24WK4
FA-PT1LBD
FA-SCBL10FM2LV-LB
FA-SCBL10FMV-M
FA-SCBL20FMV-M
FA-TB16XY
FA-TB16XY1
FA-TB16XY2
FA-TB32XY
FA-TB32XYH
FA-TB32XYL
FA-TBS32XY
FA-TBS40P
FA-TE32XY
FA-TH16XRA20S
FA-TH16YRA11S
FA-TH16YRA20S
7
No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
7-4
7. Common Elements & Appendix
Warranty
Warranty
Please confirm the following product warranty details prior to product use.
Gratis Warranty Terms and
Gratis Warranty Range
If any fault or defect (hereinafter referred to as “Failure”) attributable
to Mitsubishi Electric should occur within the gratis warranty period,
Mitsubishi Electric shall replace the product free of charge via the
distributor from whom you made your purchase.
Gratis Warranty Period
The gratis warranty period of this product shall be one (1) year
from the date of purchase or delivery to the designated place.
Gratis Warranty Range
(1) The gratis warranty range shall be limited to normal use
based on the usage conditions, methods and environment,
etc., defined by the terms and precautions, etc., given in the
instruction manual, user’s manual, and caution labels on the
product.
(2) In the following cases, a repair fee shall be applied even if
within the gratis warranty period.
1) Failure resulting from inappropriate storage or handling,
carelessness or negligence by the user, or Failure caused
by the user’s hardware or software design.
2) Failure caused by unapproved modifications, etc., to the
product by the user.
3) Failure that could have been avoided if, when the
Mitsubishi Electric Engineering product was assembled
into the user’s device, safeguards defined by legal
regulations applicable to the user’s device or functions or
structures considered standard by the industry had been
provided.
4) Failure recognized as preventable if the consumed
products specified in instruction manuals, etc., were
normally maintained or replaced.
5) Replacement of consumable parts (relays, etc.).
6) Failure caused by external factors beyond anyone’s
control such as fires or abnormal voltage, and Failure
caused by Force Majeure such as earthquakes, lightning,
or wind and water damage.
7) Failure caused by reasons unpredictable by scientific
technology standards at the time of shipment from
Mitsubishi Electric Engineering.
8) Any other failure not attributable to Mitsubishi Electric
Engineering or found by the user to not be attributable to
Mitsubishi Electric Engineering.
Common Elements
& Appendix
7
7-5
Announcement of discontinuation
of production
Discontinuation of production shall be announced to distributors six
(6) months prior to product discontinuation.
Exclusion of opportunity loss and
secondary loss from warranty liability
Regardless of the gratis warranty period, Mitsubishi Electric
Engineering shall not be liable for compensation for damages
arising from causes not attributable to Mitsubishi Electric
Engineering, opportunity losses or lost profits incurred by the user
due to Failures of Mitsubishi Electric Engineering products,
damages or secondary damages arising from special
circumstances, whether foreseen or unforeseen by Mitsubishi
Electric, compensation for accidents, compensation for damages to
products other than Mitsubishi Electric Engineering products, or
compensation for replacement work, readjustment of onsite
machinery and equipment, startup test runs or other duties carried
out by the user.
Changes in product specifications
The specifications given in the catalogs, manuals, and technical
documents are subject to change without notice.
Product application
This product shall be used in applications that will not lead to a
major accident even in the unlikely event any failure or defect
should occur in the product in which the product is incorporated,
and shall be systematically provided with external backup and
fail-safe functions that operate in the event of any failure or defect.
7. Common Elements & Appendix
Safety Precautions
Safety Precaution
Before using this product, please read this catalog as well as the technical materials, etc., of related devices carefully and pay full attention to
safety to ensure that the product is used correctly.
In this manual, the safety precautions are classified into two levels: “ WARNING” and “ CAUTION”.
WARNING
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
CAUTION
ndicates that incorrect handling may cause hazardous conditions, resulting in minor or moderate
injury and/or property damage.
Under some circumstances, failure to observe the precautions given under “ CAUTION” may lead to serious consequences.
Observe the precautions of both levels because they are important for personal and system safety.
[Design Precautions]
WARNING
● Provide safety circuits external to the product to ensure that the entire system operates safely even when a fault occurs in the external
power supply, the programmable controller, or this product. Failure to do so may result in an accident due to an incorrect output or
malfunction.
1) Configure external safety circuits, such as an emergency stop circuit, protection circuit, and protective interlock circuit for
forward/reverse operation or upper/lower limit positioning designed to prevent machinery damage.
2) Outputs may remain on or off due to a failure of an output relay, transistor, triac, or the like. Provide an external circuit for monitoring
output signals that could cause a serious accident.
● If overcurrent more than the rating or overcurrent due to a short circuit flows in an output module for a long time, it may cause smoke or
a fire. To prevent this, provide an external safety circuit, such as a fuse.
[Design Precautions]
CAUTION
● Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm
or more between them. Failure to do so may cause malfunctions due to noise.
[Installation Precautions]
WARNING
● Be sure to shut off the external power supply in all phases before installation. Failure to do so may result in electric shock.
[Installation Precautions]
7
● Use this product in an environment that meets the specifications and general specifications given in this catalog. Operation in any other
environment may cause electric shock, fire, malfunction, product damage, and/or deterioration.
● Securely fix the module with a DIN rail or screws. Be sure to secure the cables in a duct or by a clamp. Failure to do so may cause
falling, damage, or poor contact. When securing the module, tighten the screws within the specified torque range. Undertightening can
cause screws to fall out, a short circuit, or malfunction. Overtightening can damage the screw and/or product, causing screws to fall out,
a short circuit, or malfunction.
● Do not directly touch any conductive part of the module. Doing so may cause product malfunction or failure.
● If the product has a designated installation direction, install the product in accordance with that designation. Installing the product in a
direction other than the designated direction may cause product damage or deterioration.
● When drilling screw holes, be careful that the cutting debris does not enter the product interior or conductive parts. Failure to do so may
cause fire, failure, and/or malfunction.
● When detaching or attaching a replacement relay, be sure to first disconnect the power supply. Failure to do so may cause failure
and/or malfunction.
● Securely fit the replacement relay to the module. Improper mounting may cause damage, falling, and/or malfunction due to poor
contact. Additionally, detach and attach the module following the proper procedures. Failure to do so may cause damage, falling, and/or
malfunction due to poor contact.
Common Elements
& Appendix
CAUTION
7-6
7. Common Elements & Appendix
Safety Precautions
[Wiring Precautions]
WARNING
● Be sure to shut off the external power supply used in the system in all phases before wiring. Failure to do so may cause electric shock
or product damage.
● When energizing and operating the product after wiring, be sure to first install the provided terminal cover to the product. Failure to do
so may cause electric shock.
[Wiring Precautions]
CAUTION
● Use applicable solderless terminals and tighten the terminals based on the specified torque.
● Properly wire the product upon verification of the rated voltage and terminal layout of the product. Connecting the power supply after
inputting a voltage different from the rated voltage or executing mistaken wiring may cause fire, failure, and/or malfunction.
● When connecting the product with a programmable controller, first verify that the product configuration is correct. Connection based on
a wrong configuration may cause failure or malfunction.
● Securely mount the module and cable connectors to the mounting area. Failure to do so may cause malfunction.
● Use the product with the connectors of the products not subjected to additional force. Failure to do so may cause failure or
disconnection.
● Securely mount the connection cables and peripheral device cables to the predetermined connectors. Failure to do so may cause
malfunction caused by poor contact.
● Use the product with the connectors of the peripheral device cables not subjected to additional force. Failure to do so may cause
disconnection or failure.
● When disconnecting a cable, do not pull the cable line. Disconnect a cable that has a connector by holding the connector of the
connected part in your hand. Disconnect a cable without a connector by first loosening the screws, etc., of the part connected to the
module. Pulling the cable in a connected state may cause module and/or cable damage, or malfunction due to poor contact.
● Mount a protective cover or module on unused connectors and sockets of the module. Failure to do so may cause entry of foreign
matter, which may cause fire, failure, and/or malfunction.
● Be careful that wire chips do not enter the product interior or conductive parts. Failure to do so may cause fire, failure, and/or
malfunction.
[Startup and Maintenance Precautions]
WARNING
● Do not touch terminals while power is supplied to the product. Doing so may cause electric shock and/or malfunction.
● Be sure to shut off the external power supply used in the system in all phases before cleaning or further tightening terminal or module
screws. Failure to do so may cause electric shock and/or malfunction.
Tighten the screws within the specified torque range. Undertightening can cause screws to fall out, short circuits, or malfunction.
Overtightening can damage the screw and/or product, causing screws to fall out, a shortcircuit, or malfunction.
[Startup and Maintenance Precautions]
CAUTION
● Be sure to shut off the external power supply used in the system in all phases before detaching or attaching the product. Failure to do
so may cause product failure and/or malfunction. Be sure to use the online attachable/detachable (hot-pluggable) RS232 ↔ RS422
communication converter using the QCPU-side connector (mini DIN6P).
● Attach and detach modules, cables, etc., no more than 50 times after the start of product use. Exceeding 50 times (IEC61131-2
compliant) may cause malfunction.
● Use wireless communication devices, such as mobile phones, PHSs, etc., at least 25cm away from the area surrounding the product
and programmable controller. Failure to do so may cause malfunction.
● Before touching the product, be sure to touch a grounded metal or the like to discharge the static electricity charged from the human
body. Failure to do so can cause product failure or malfunction.
● Do not disassemble or modify the product. Doing so may cause failure, malfunction, and/or fire.
[Disposal Precautions]
CAUTION
Common Elements
& Appendix
7
7-7
● When disposing of this product, treat it as industrial waste.
[Disposal Precautions]
CAUTION
● This product is a precision instrument. During transportation, avoid impacts larger than the range specified in the general specifications.
Failure to do so may cause failures in the product.
7. Common Elements & Appendix
Related Catalog
Related Catalog
The following catalogs are provided, describing the detailed information of related products.
Programmable Controller Upgrade Tool General Catalog (NAC095E●134)
The upgrade tool is a handy tool for upgrading
your current series to the MELSEC-Q
Connector series.
Simplifies replacement with MELSEC-Q
●MELSEC-A (large-size) → MELSEC-Q replacement
●SYSMAC C → MELSEC-Q replacement
C
Significantly reduces
the input, output,
analog, and high-speed counter module
wiring time
Allows reuse of sequence programs
2
7
7
& ppendix
Common
Elements
& Appendix
(Applicable only for the SYSMAC C → MELSEC-Q
replacement)
7-8
1-13-5, Kudankita, Chiyoda-ku, Tokyo, 102-0073, Japan Phone +81-3-3288-1101 Fax +81-3-3288-1507 URL:http://www.mee.co.jp/
For safe operations
This product has been manufactured as a general-purpose part for general industries, and has not been designed or
manufactured to be incorporated in a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mutsubushi Electric Engineering.
This product has been manufactured under strict quality control. However, when installing the product where major accidents
or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Stores
Before using this product, ensure the safety in case of failure. We shall not bear any responsibility for consequential damages caused by failure of the product.
MEI C098E 136 (1306)MEE
(SAN C015 019Qa(1301))
New publication, effective Jun. 2013
Specifications subject to change without notice.