RADIO REMOTE CONTROLS
Radio remote control senders and receivers
These products are used for the remote control switching or dimming of lighting or other loads. The wire-free senders are available
as hand held or wall mounted versions.
A receiver switch or receiver dimmer is wired into the existing circuit to control the connected load. The sender signals can
pass through walls or ceilings so the receivers can be mounted out of sight. Inside a typical building the receivers can work at
an approximate range of 30-50 metres. In free air the range is approximately 100-150 metres. The carrier frequency of the radio
signals is 868MHz, which is CE Approved and Licence Free.
An example building
Radio receivers
Exterior receiver switch
for outside lights.
Display cabinet lamps or
standard desk lamps can
be controlled via a plug-in
dimmer receiver.
Receiver switches and
receiver dimmers for the
lighting circuits can
be concealed behind a
false ceiling.
Wire-free radio senders
12 channel hand sender to control
ceiling lights, spot lights and screen.
For security reasons a caretaker can
use another 12 channel hand sender to
control all the lights inside the building
and the outside security lights.
70
All lights can also be
controlled by wire-free
wall mounted senders.
RADIO REMOTE CONTROLS
Radio remote control functions
Each button on each sender sends a unique coded signal (one of 4 billion codes).
A simple set-up procedure enables any chosen receiver to respond to the signal from any
chosen sender button. The sender button then controls the receiver (and its connected
load). This simple procedure is repeated, creating links between various sender buttons
and various receivers.
As shown, almost any control set-up is possible; from a single room to an entire building.
For the simplest
set-up, one
receiver can be
controlled by one
sender.
Receiver
Sender
Any receiver can
be programmed to
respond to the unique
coded signal from
any sender button.
Hence, a sender
button can control any
number of receivers
simultaneously.
Also a single receiver can be controlled by up to 15
sender buttons.
These control combinations can be mixed and matched, making
it possible to have almost any control set-up desired; from the
simplest single room to an entire building.
In the above control set-up, one button on the left hand sender
controls the first receiver. A different button on the left hand
sender controls the first and second receivers simultaneously,
and so on.
Typical penetration of radio signals
The radio signals cannot pass through
the entire length of walls.
The radio signals achieve a range of
approximately 30-50m inside a building;
100-150m in free air.
Brick walls:
approx. 60-90%
penetration
Timber
framework
with sandwich
plasterboards:
approx. 80-95%
penetration
Reinforced
concrete:
approx. 20-60%
penetration
Metal walls:
approx. 0-10%
penetration
Conventional
glass: approx.
70-90%
Insulating glass
(with vaporised
metal coat):
approx. 30-60%
penetration
Plastics:
approx. 80-95%
penetration
71
RADIO REMOTE CONTROLS
Radio remote control wire-free hand senders
12 channel hand held sender
frontin mm
Dimensions
side
54
Sends on 12 unique channels.
Complete with two AAA batteries.
20
Specification
Signal range: Up to 150m in free air
Carrier frequency: 868MHz (CE Approved,
Licence Free)
Dimensions: 152
152 x 54 x 20mm
Order code: HASE 12RFC
2 channel key fob sender
Sends on 2 unique channels.
Complete with CR2430 battery.
With optional wall mounting fixing.
Dimensions in mm
front
side
46
16
Specification
Signal range: Up to 100m in free air
86
Carrier frequency: 868MHz (CE Approved,
Licence Free)
Dimensions: 86 x 46 x 16mm
Order code: HASE 2RF
Radio remote control programmer
Ideal for controlling lighting or other loads to switch
on/off at specific pre-programmed days and times.
Dimensions in mm
Sends on 1 unique channel.
front
side
64
60
Plugs into a UK 3-pin mains socket.
8 ON / 8 OFF switching commands available each
day (56 ON / 56 OFF each week).
Self cancelling ON and OFF override.
112 memory locations.
Order code: PLPR 1RF
Shortest switching interval - 1 minute.
Specification
Wiring: Plugs into 13 amp mains socket
Dimensions: 120 x 64 x 60mm
Also available: Slave senders See page 79 for details.
72
120
RADIO REMOTE CONTROLS
Radio remote control wire-free wall senders
All DANLERS radio remote control wall or hand senders operate on a carrier frequency of
868MHz (CE Approved, Licence Free).
Wire-free. No wall box needed.
Complete with CR2430 battery(ies).
Simple programming procedure.
Requires compatible DANLERS receiver switch or receiver dimmer to operate.
Wall senders can be wall mounted or mounted on other working surfaces using the
supplied adhesive strips or screwed to a fixed surface via the surface mounting plate
behind the clip on front plate.
Specification
Signal range: Up to 100m in free air
Carrier frequency: 868MHz (CE Approved, Licence Free)
WASE 1RF WHI Sends on 1 unique channel.
Dimensions: Dimensions in mm
87 x 87 x 15mm
front
side
87
15
87
Order code: WASE 1RF WHI
WASE 2RF WHI Sends on 2 unique channels.
Dimensions: Dimensions in mm
87 x 87 x 15mm
front
side
87
15
87
Order code: WASE 2RF WHI
WASE 4RF WHI Sends on 4 unique channels.
Dimensions: Dimensions in mm
87 x 87 x 15mm
front
side
87
15
87
Order code: WASE 4RF WHI
Also available:
A range of different colours and finishes are available on request.
Please ask for details.
73
RADIO REMOTE CONTROLS
Radio receiver switches
Wall or ceiling mounted switch: WACE RFS
Hard wired. Can be mounted on a 16mm box.
Can be mounted out of sight.
Specification
Loading: Order code: WACE RFS
Order code:
CEFL RFS
Dimensions in mm
plan
side
86
22
Up to 6 amps (1500W) of
resistive load or up to 1 amp
(250W) of transformer or
fluorescent load
Wiring diagram: See diagram 74 below
Dimensions: 86 x 86 x 22mm
86
Ceiling flush mounted switch: CEFL RFS
Complete with 2m cable for quick and easy installation. Loading and wiring as for WACE RFS.
72mm diameter x 68mm (requires 63mm diameter hole)
Dimensions: Order code:
CEVO RFS
Hard wired switch: CEVO RFS
Complete with 2m cable for quick and easy installation. Ideal for ceiling voids.
Will fit through a 63mm diameter aperture. Loading and wiring as for WACE RFS.
Dimensions: 60mm diameter x 130mm
Plug-in switch: CERF S6A
Dimensions in mm
Plugs into a Ceiling socket (shown on p.78).
Can be mounted out of sight.
plan
side
72
57
Specification
Loading: Order code: CERF S6A
Requires socket, order code:
CESO or CESO SQ (see page 78)
Up to 6 amps (1500W) of any type of
load, including fluorescent lights or
up to 1 amp (250W) of fans
Wiring diagram: See diagram 74 below
Dimensions: 130 x 72 x 57mm
130
Also available: Hard wired switch: CEVO RFS6A
Complete with 2m cable for quick and easy installation. Loading and wiring as CERF S6A.
Dimensions: 130 x 72 x 57mm
DIN rail receiver switch: DIN RFS
Dimensions in mm
For fixing on to either 35 x 7.5mm top-hat DIN rail
or 32 x 15mm G-type DIN rail.
plan
side
75
35
Specification
Loading: Order code: DIN RFS
Up to 6 amps (1500W) of resistive
load or up to 1 amp (250W) of
transformer or fluorescent load
Wiring diagram: See diagram 74 below
Dimensions: 35 x 75 x 100mm
DIN rail receiver dimmer also available on request.
Wiring diagram
74. Remote control switching
receiver switch
L
SL
230 VAC
wire-free
sender
N
74
load
100
RADIO REMOTE CONTROLS
Radio receiver switches
Plug-in adaptor switch: PORF S8A
Dimensions in mm
Plugs into a UK 3-pin mains socket and has its
own 3-pin socket for a mains powered plug-in
device. Ideal for table lamps or displays.
front
side
60
48
Specification
Loading: Order code:
PORF S8A
Up to 8 amps (2000W) of
resistive load or up to 1 amp
(250W) of transformer or
fluorescent load
Wiring: Plugs into 13 amp mains socket
Dimensions: 138 x 60 x 48mm
138
Exterior switch: EXRFS
Dimensions in mm
Hard wired. Outdoor mounted. Weatherproof to
IP65 rating.
front
side
98
35
Specification
Loading: Up to 6 amps (1500W) of
resistive load or up to 1 amp
(250W) of transformer or
fluorescent load
64
Wiring diagram: See diagram 75a below
Dimensions: 98 x 64 x 35mm
Order code:
EXRFS
Dual momentary switch: WACE RF2S
Dimensions in mm
Hard wired. Wall or ceiling mounted.
Twin actuator switch. Enables blinds to be
opened, closed or adjusted to any position
required. Can be mounted on a 16mm box.
Can be mounted out of sight.
plan
side
86
22
WACE RF2S can also be used as a slave to
control up to two DANLERS grid time lag or
soft start dimmer switches. This can allow RF
control of higher wattage loads including toroidal
transformers.
86
Specification
Order code:
WACE RF2S
Loading: Up to 6 amps (1500W) of resistive load or up to 1 amp (250W) of
transformer or fluorescent load
Wiring diagram: See diagrams 75b and 75c below
Dimensions: 86 x 86 x 22mm
Wiring diagrams
75a. Remote control switching
75b. Blind/motor control switch
L
WACE RF2S
receiver switch
L
SL
230 VAC
230 VAC
wire-free
sender
N
wire-free
sender
load
N
SL 1
L
L
75c. Soft start dimmer with remote control
(high current)
SL 2
Contactor
L
WACE
RF2S
230 VAC
N
Contactor
Down
Motor
Up
Motor
N
N
wire-free
sender
SL
S
soft start
dimmer
L
V
load
75
RADIO REMOTE CONTROLS
Radio receiver dimmers (trailing edge)
Wall or ceiling mounted dimmer:
WACE RFD250W
Dimensions in mm
Hard wired. Can be mounted on a 16mm box.
Can be mounted out of sight.
Specification
Loading: Order code: WACE RFD250W
Order code:
CEFL RFD250W
plan
side
86
22
Up to 250W of resistive,
mains halogen* or dimmable
electronic transformer loads
86
Dimming technology:Trailing edge
Wiring diagram: See diagram 77a on page 77
Dimensions: 86 x 86 x 22mm
Also available: Ceiling flush mounted dimmer: CEFL RFD250W
Complete with 2m cable for quick and easy installation.
Loading and wiring as for WACE RFD250W.
Dimensions: 72mm diameter x 68mm (requires 63mm diameter hole)
Also available: Hard wired dimmer: CEVO RFD250W
Order code:
CEVO RFD250W
Complete with 2m cable for quick and easy installation.
Ideal for ceiling voids.
Will fit through a 63mm diameter aperture.
Loading and wiring as for WACE RFD250W.
Dimensions: 60mm diameter x 130mm
Plug-in adaptor dimmer: PORF D250W
Dimensions in mm
Plugs into a UK 3-pin mains socket and has its own
3-pin socket for a mains powered plug-in device.
Ideal for table lamps or displays.
front
side
60
48
Specification
Loading: Up to 250W of resistive, mains
halogen* or dimmable electronic
transformer loads
138
Dimming technology:Trailing edge
Wiring: Plugs into 13 amp mains socket
Dimensions: 138 x 60 x 48mm
Order code:
PORF D250W
Exterior dimmer: EXRF D250W
Hard wired. Outdoor mounted.
Weatherproof to IP65 rating.
Dimensions in mm
Specification
front
side
98
35
Loading: Up to 250W of resistive,
mains halogen* or dimmable
electronic transformer loads
64
Dimming technology:Trailing edge
Wiring diagram: See diagram 77a on page 77
Dimensions: 98 x 64 x 35mm
Order code: EXRF D250W
*Mains halogen lamps must have an integral thermal safety fuse.
76
151
plan
f
RADIO REMOTE CONTROLS
Radio receiver dimmers (trailing edge)
Plug-in dimmer: CERF D500W
Dimensions in mm
Plugs into a Ceiling socket (shown on p.78).
Can be mounted out of sight.
Dimensions in mm
plan
side
72
57
Specification
Loading: Order code: CERF D500W
Requires socket, order code:
CESO or CESO SQ (see page 78)
Up to 500W of resistive,
mains halogen* or dimmable
electronic transformer loads
130
Dimming technology:Trailing edge
Wiring diagram: See diagram 77a below
Dimensions: 130 x 72 x 57mm
Build-in dimmer: CERF D500W GT
Dimensions in mm
Ideal for building into a luminaire or gear tray.
Hard wired build-in dimmer.
151
plan
Specification
Loading: 34
Up to 500W resistive, mains
halogen* or dimmable electronic
transformer loads
Order code:
CERF D500W GT
151
side
Dimming technology: Trailing edge
Wiring diagram: See diagram 77a below
Dimensions: 151 x 34 x 28mm
28
Build-in dimmer: CERF D10VDC MB
Dimensions in mm
Ideal for building into a luminaire or gear tray.
For controlling dimmable ballasts with a 1-10VDC
analogue input.
151
plan
34
Specification
Loading: Order code:
CERF D10VDC MB
Up to 6 amps (1500W) of
resistive load or up to 4 amps
(1000W) of fluorescent load.
Total load of ballasts, lamps plus
other loads not more than 2 amps.
Can control up to 20mA, eg. 20
ballasts at 1mA.
151
side
28
Dimming technology: 1 to 10V with relay off
Wiring diagram: See diagram 77b below
Dimensions: 151 x 34 x 28mm
Wiring diagrams
77a. Remote control dimming
77b. CERF D10VDC MB controlling several
1-10VDC dimmable ballasts
control lines
receiver dimmer
L
CERF D10VDC MB
V
L
230 VAC
SL
230 VAC
1
ballast
10
1
ballast
10
wire-free
sender
*Mains halogen lamps must have an integral
thermal safety fuse.
N
load
N
wire-free
sender
1
ballast
10
77
RADIO REMOTE CONTROLS
Sockets and slave relays
Ceiling socket: CESO
CESO
Dimensions in mm (CESO)
For DANLERS plug-in switches or dimmers.
Can be mounted on a BESA box.
74
plan
74
side
Specification
13
Wiring diagram: See diagram 78a below
Dimensions: Order code: CESO
74mm diameter x 13mm
CESO
SQ
Dimensions
in mm (CESO SQ)
Also available as a square socket.
87
plan
side
13
Ceiling socket: CESO SQ
Order code:
CESO SQ
Can be mounted on a square pattress box.
87
Wiring diagram: See diagram 78a below
Dimensions:
87 x 87 x 13mm
Ceiling slave relay: CESL
Dimensions in mm
For DANLERS plug-in switches only. Provides
an extra 1-pole isolated changeover contact.
Enables the switching of an additional circuit with
its own supply, e.g. the corridor lights outside an
office or a separate low voltage control circuit.
plan
side
87
87
Specification
Loading: 41
87
(Each circuit) up to 6 amps
(1500W) of resistive, fluorescent
or transformer lighting loads, or
up to 1 amp (250W) of fans
Wiring diagram: See diagram 78b below
Order code: CESL
Dimensions: 87 x 87 x 41mm
Ceiling double slave relay: CE2SL
Dimensions in mm
For DANLERS plug-in switches only. Provides
extra 2-pole isolated changeover contacts.
Enables the switching of two additional circuits,
each with its own supply, e.g. the corridor lights
outside an office and the extractor fans inside the
office. Also ideal for switching two separate low
voltage control circuits.
plan
side
87
87
41
87
Specification
Loading: (Each circuit) up to 6 amps
(1500W) of resistive, fluorescent
or transformer lighting loads, or
up to 1 amp (250W) of fans
Order code: CE2SL
Wiring diagram: See diagram 78c below
Dimensions: 87 x 87 x 41mm
Wiring diagrams
78a. Ceiling mounted socket (CESO or
CESO SQ) for plug-in ceiling controls
L
N
78b.Plug-in control plus slave relay with volt
free changeover contacts (CESL)
controlling one extra circuit
78c.Plug-in control plus double slave relay
with volt free changeover contacts
(CE2SL) controlling two extra circuits
separate circuit
separate circuit
SL 2
BESA box or
pattress
box
N/O
SL2
SL 2
N/O
N/C
C2
separate circuit
SL2 SL3
N/C
N/O
C3 SL3
N/C
SL
L1
CESO or
CESO SQ
L
78
C2
N
SL
plug-in ceiling
control
luminaire
Not to scale
optional manual
wall switch for
overriding off
230 VAC
N1
CESL
plus
plug-in
switch
L1
SL1
load
optional manual
wall switch for
overriding off
230 VAC
N1
CE2SL
plus
plug-in
switch
SL1
load
RADIO REMOTE CONTROLS
Slave radio senders
For use with DANLERS plug-in switches, such as PIR occupancy switches or Photocell
switches. For controlling other remote circuits via Radio receiver switches or dimmers
(shown on pages 74 to 77).
The SLSE 1RFSO is hard wired.
Requires mains power supply.
Sends on 1 unique channel.
For programming, requires Test plug (order code TEPL).
Dimensions in mm
plan
side
87
41
Specification
Signal range: Order code: SLSE 1RFSO
Up to 100m in free air
87
Wiring diagram: See diagram 79 below
Dimensions: 87 x 87 x 41mm
Wiring diagram
79. Radio slave
sender and
radio receiver
DANLERS
plug-in
switch
L
L1
SLSE 1RFSO
Radio receiver
load
230 VAC
230 VAC
N
N1
Also available on request:
Outdoor 2 channel slave radio sender (Order code: EXSLSE 2RF).
Customised functions and scene-setting
By special order DANLERS can supply packages of Senders and Receivers which are
factory pre-programmed to perform specified special switching and/or dimming functions.
The table lists some of the special functions that are available, plus examples of how
these functions may be used.
Even packages which perform several different functions can be supplied.
Please note there is an additional charge to customise for special requirements and a
charge for programming on site.
Please call to discuss your particular requirements.
Special switching function
Example application
Time delay ON
For a special stage effect
Time delay OFF
A courtesy light for leaving a building
Time delay OFF with warning
Demand for lighting for few minutes in a
stock cupboard, with flashing prompt to
re-press the sender before the lights go out
Momentary ON
To sound a doorbell
Flashing
To give an alert signal (e.g. testing in
progress)
Motor control
To open and close blinds, screens or shutters
Special dimming function
Example application
Gradual dimming or brightening
Theatre house lights or presentation rooms
Select a pre-set lamp brightness
To set a mood for restaurant lighting
Gradual dim to pre-set level
To give comfortable background lighting in a
conference
To give a subtle switch on effect for a
hotel room
Soft start switch on
79