Passlock 2003
Bypass module for Passlock GM I et II,Saturn,
Hummer H2, VATS and Saturn ION
MODE 1
P AS S L O C K I :
CAVALIER
1995 - 1999
SUNFIRE
1995 - 1999
GRAND AM 1995 - 1998
SKYLARK
1996 - 1998
Programmation Passlock I, II and VATS (MODE 1):
Once the Passlock 2003 is correctly connected.
Place the mode selector to Mode 1, Start the vehicle with the key.
Ajust the potentiometer (max. 20 turns) until the LED turns OFF.
Ajust the LED to the middle of the illuminated window.
The module is now ready to use in Mode 1.
Programmation Passlock Saturn ION & others (MODE 2):
Once the Passlock 2003 is correctly connected with the black wire to ground.
Place the mode selector to Mode 1 to begin programmation procedure.
Start the vehicle with the key, with the key in the crank position adjust the
potentiometer until the LED turn OFF.
Turn the key to the OFF position and place the mode selector to Mode 2.
The module is now ready to use in Mode 2.
Compatible with others vehicles, visite our web site
http://support.fortinautoradio.com
VEHICLE
P AS S L O C K I I :
Escalade
1999 - 2005
Astro-safari 1998 - 2005
C/K Pickup
1998 - 2005
Avalanche
2002 - 2005
CAVALIER
2000 - 2005
SUNFIRE
2000 - 2005
PASSLOCK
Blazer
Envoy-Jimmy
Express-Van
Impala-Monte
Malibu
S-10/15
Tahoe-Yukon
Silverado
Intrigue
Alero
Bravada
Hummer H2
II : suite
1998 - 2004
1998 - 2005
1998 - 2005
2000 - 2005
1997 - 2003
1998 - 2001
1998 - 2005
2000 -2005
1997- 2001
1999 - 2003
1998 - 2005
2002 - 2005
PASSLOCK
SaturnL300
Saturn Sedan
Saturn Vue
II : suite
2002 -2004
2000-2002
2002-2005
Chevrolet Equinox
Key
sence
Option
2005
MODE 2 VEHICLE
Saturn ION
2003-2005
Chevrolet Cobalt
2005
Pontiac Pursuit
2005
LED OFF
LED ON
Installation
(MODE 1)
Passlock I et II
LED ON
POTENTIOMETER POSITION
White
Black or orange/ black
Yellow
MODE SELECTEUR
Mode 1
Installation
(MODE 1)
VATS
GM ou
Saturn
Installation
(MODE 2)
GM
Saturn
or GM
White / black
White (ground)
White (1V à 5V)
White
Cut
Brown
Mode 2
LED
POT.
View from the front of the module
Black
Yellow
White
Pink
Purple
Brown
Blue
Green
PASSLOCK
2003
MADE IN CANADA
(GROUND) Connect to ground for Mode 2
(DATA OUT)
(2 d IGNITION 12V OUT)
(MAIN IGNITION 12V IN)
(STARTER IN+) Use for Passlock I and Mode 2 only
(BULB TEST OUT-) Use for Passlock I only
(IN RUNNING -)
(DATA IN) Use for Mode 2 only
Acc. Out +
Start out +
Out Running -
GROUND for
Mode 2 and
VATS only
Key sence Option
Note:
Neither the manufacturer or distributor of this module
are responsible of damages of any kind indirectly or directly
caused by this module, except for the replacement of this
module in case of manufacturing defects.
SUPPORT TECHNIQUE :
TEL : 514-255-0446
FAX: 514-255-1367
Web: http://support.fortinautoradio.com
Version : 1.2
Revision : 02-14-2005
REMOTE
STARTER
Équinox
ONLY
Connect on
key sence (-) to turned off
security light.
Passlock 2003
Bypass module for Passlock GM I et II,Saturn,
Hummer H2, VATS and Saturn ION
MODE 1
P AS S L O C K I :
CAVALIER
1995 - 1999
SUNFIRE
1995 - 1999
GRAND AM 1995 - 1998
SKYLARK
1996 - 1998
Programmation Passlock I, II and VATS (MODE 1):
Once the Passlock 2003 is correctly connected.
Place the mode selector to Mode 1, Start the vehicle with the key.
Ajust the potentiometer (max. 20 turns) until the LED turns OFF.
Ajust the LED to the middle of the illuminated window.
The module is now ready to use in Mode 1.
Programmation Passlock Saturn ION & others (MODE 2):
Once the Passlock 2003 is correctly connected with the black wire to ground.
Place the mode selector to Mode 1 to begin programmation procedure.
Start the vehicle with the key, with the key in the crank position adjust the
potentiometer until the LED turn OFF.
Turn the key to the OFF position and place the mode selector to Mode 2.
The module is now ready to use in Mode 2.
Compatible with others vehicles, visite our web site
http://support.fortinautoradio.com
VEHICLE
P AS S L O C K I I :
Escalade
1999 - 2005
Astro-safari 1998 - 2005
C/K Pickup
1998 - 2005
Avalanche
2002 - 2005
CAVALIER
2000 - 2005
SUNFIRE
2000 - 2005
PASSLOCK
Blazer
Envoy-Jimmy
Express-Van
Impala-Monte
Malibu
S-10/15
Tahoe-Yukon
Silverado
Intrigue
Alero
Bravada
Hummer H2
II : suite
1998 - 2004
1998 - 2005
1998 - 2005
2000 - 2005
1997 - 2003
1998 - 2001
1998 - 2005
2000 -2005
1997- 2001
1999 - 2003
1998 - 2005
2002 - 2005
PASSLOCK
SaturnL300
Saturn Sedan
Saturn Vue
II : suite
2002 -2004
2000-2002
2002-2005
Chevrolet Equinox
Key
sence
Option
2005
MODE 2 VEHICLE
Saturn ION
2003-2005
Chevrolet Cobalt
2005
Pontiac Pursuit
2005
LED OFF
LED ON
Installation
(MODE 1)
Passlock I et II
LED ON
POTENTIOMETER POSITION
White
Black or orange/ black
Yellow
MODE SELECTEUR
Mode 1
Installation
(MODE 1)
VATS
GM ou
Saturn
White (ground)
White (1V à 5V)
Installation
(MODE 2)
GM
Saturn
or GM
White / black
White
Cut
Brown
Mode 2
LED
POT.
View from the front of the module
PASSLOCK
2003
MADE IN CANADA
Black
Yellow
White
Pink
Purple
Brown
Blue
Green
(GROUND) Connect to ground for Mode 2
(DATA OUT)
(2 d IGNITION 12V OUT)
(MAIN IGNITION 12V IN)
(STARTER IN+) Use for Passlock I and Mode 2 only
(BULB TEST OUT-) Use for Passlock I only
(IN RUNNING -)
(DATA IN) Use for Mode 2 only
Version : 1.2
Revision : 02-14-2005
Acc. Out +
Start out +
Out Running -
GROUND for
Mode 2 and
VATS only
SUPPORT TECHNIQUE :
TEL : 514-255-0446
FAX: 514-255-1367
Web: http://support.fortinautoradio.com
Key sence Option
Équinox
ONLY
Connect on
key sence (-) to turned off
security light.
REMOTE
STARTER
Note: Neither the manufacturer or distributor of this module
are responsible of damages of any kind indirectly or directly
caused by this module, except for the replacement of this
module in case of manufacturing defects.