Optiset Plus
•
Named Products or Numeric Setpoint -The
controller can be programmed to allow named
products or numeric setpoints to be selected. In
which case the far left soft key will display PRODUCT/
SETPOINT as shown below.
The controller can be programmed with OptiSet Plus
temperature profiles that allow the user to select named
products and/or numeric setpoints. See the appropriate
Operator’s Manual for more detailed information about
using OptiSet Plus.
•
5.
The “Setpoint” Screen briefly appears, then the
“Current Setpoint Is” Screen will appear.
6.
Press the + or - soft keys to change the setpoint.
1.
Begin at the Standard Display.
If the Temperature Watch Display is showing, press
the MENU soft key once to return to the Standard
Display.
2.
Press the PRODUCT/SETPOINT (or PRODUCT) soft
key on the Standard Display.
6
Numeric Setpoint - If the controller does not have
named products loaded, the far left soft key will
display SETPOINT as shown below. This is the factory
default setting. Change the numeric setpoint like you
normally would on an SR-3 Controller.
7.
1
Press the YES soft key to select the new setpoint.
2
7
Selecting a Numeric Setpoint
•
Named Products - The controller can be
programmed to allow only named products to be
selected. In which case the far left soft key will
display PRODUCT as shown below.
Named products can have a single setpoint, or they
can have a setpoint range that allows the user to
select a setpoint within that range.
To select or change a numeric setpoint complete the
following steps. This example shows the Standard Display
with the PRODUCT/SETPOINT soft key. Using the
Standard Display with the SETPOINT soft key is basically
the same but some of the screens differ slightly.
1.
Begin at the Standard Display.
If the Temperature Watch Display is showing, press
the MENU soft key once to return to the Standard
Display.
Press the PRODUCT/SETPOINT (or SETPOINT) soft
key on the Standard Display.
2.
•
If the NO key is pressed the setpoint change selected
with the + or - soft keys will not be accepted, the
setpoint will not be changed and the display will
return to the Standard Display.
•
If the YES soft key is pressed, the setpoint change
selected with the + or - soft keys will be accepted,
and the following screens will appear.
8.
The “Programming New Setpoint” Screen will briefly
appear.
9.
The “New Setpoint Is 40” Screen briefly appears.
3.
The “Named Product / Numeric Setpoint?” (or Named
Product) Screen briefly appears, then the “Named
Product or Numeric Setpoint?” (or Named Product)
Screen will appear.
4.
Press the NAMED soft key.
4
5.
The “Product” Screen briefly appears, then the
“Current Product Is” Screen will appear.
6.
Press the + or - soft keys to change the named
product.
10. The Standard Display appears with the new setpoint.
1
2
6
NOTE: Pressing the EXIT soft key at any point will
return to the Standard Display.
NOTE: In OptiSet Plus the terms “numeric setpoint”
and “setpoint” mean the same thing and are
displayed as numbers. The terms “named product”
and “product” mean the same thing and are displayed
as words.
NOTE: Alarm Code 127, Setpoint Not Entered, may be
generated if the + or - soft keys are used to change
the numeric setpoint or named product, but the YES
or NO soft keys are not used to accept or decline the
new setting within 10 seconds.
3.
The “Named Product / Numeric Setpoint?” Screen
briefly appears, then the “Named Product or Numeric
Setpoint?” Screen will appear.
4.
Press the NUMERIC soft key.
NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will
return to the Standard Display.
7.
Selecting a Named Product
4
To select or change a named product complete the
following steps. This example shows the Standard Display
with the PRODUCT/SETPOINT soft key. Using the
Standard Display with the PRODUCT soft key is basically
the same but some of the screens differ slightly.
Press the YES soft key to select the new named
product.
7
•
If the NO key is pressed the named product change
selected with the + or - soft keys will not be
accepted, the named product will not be changed and
the display will return to the Standard Display. (Over)
•
If the YES soft key is pressed, the named product
change selected with the + or - soft keys will be
accepted, and the following screens will appear.
8.
The “Programming Named Product” Screen will
briefly appear.
NOTE: If the “Change Setpoint for Potatoes” Screen
briefly appears, the named product has been
programmed with a setpoint range. See “Selecting
the Setpoint for a Named Product” below.
9.
Press the + or - soft keys to change the current
setpoint for the named product. Go to step 6 under
“Changing the Setpoint for a Named Product” to
continue.
•
4.
Press the CHANGE SP soft key.
4
OR
Press the EXIT soft key to accept the current setpoint
for the named product. The Standard Display will
appear with the named product and setpoint.
•
The “New Named Product Is Potatoes” Screen briefly
appears.
5.
The “Change Setpoint for Potatoes” Screen briefly
appears, then the “Current Setpoint for Potatoes &
Setpoint Range Is 40 to 50” Screen will appear.
6.
Press the + or - soft keys to change the setpoint.
10. The Standard Display appears with the new named
product.
6
NOTE: Pressing the EXIT soft key at any point will
return to the Standard Display.
NOTE: Pressing the EXIT soft key at any point will
return to the Standard Display.
NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will
return to the Standard Display.
If the “Change Setpoint for Potatoes” Screen appears
after pressing the YES soft key to select a named product,
the named product has been programmed with a setpoint
range. Complete the following steps to select a setpoint
for the named product.
2.
7.
Press the YES soft key to accept the new setpoint.
7
Changing the Setpoint for a
Named Product
•
If the NO key is pressed the named product setpoint
change made with the + or - soft keys will not be
accepted, the named product setpoint will not be
changed and the display will return to the Standard
Display.
•
If the YES soft key is pressed, the named product
setpoint change made with the + or - soft keys will be
accepted, and the following screens will appear.
8.
The “Programming New Setpoint for Potatoes”
Screen will briefly appear.
9.
The “New Setpoint Is 40” Screen briefly appears.
If the named product has been programmed with a
setpoint range, the setpoint for the named product can be
changed. This example shows the Standard Display with
the PRODUCT/SETPOINT soft key.
Selecting the Setpoint for a
Named Product
1.
NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will
return to the Standard Display and the setpoint will
remain at the displayed setpoint.
SR-3
Smart Reefer 3
Microprocessor
1.
Begin at the Standard Display.
If the Temperature Watch Display is showing, press
the MENU soft key once to return to the Standard
Display.
Press the PRODUCT/SETPOINT soft key on the
Standard Display.
2.
The “Change Setpoint for Potatoes” Screen briefly
appears, then the “Current Setpoint of Potatoes &
Setpoint Range Is 40 to 50” Screen will appear.
1
10. The Standard Display appears with the new setpoint.
Press the + /- or EXIT soft keys accordingly as
described below.
Driver Guide to
OptiSet Plus
Operation
2
2
2
3.
The “Named Product, Numeric Setpoint or Change
Setpoint?” Screen will appear.
NOTE: Pressing the EXIT soft key at any point will
return to the Standard Display.
NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will
return to the Standard Display.