owners manual - LP Adjustable Beds

owners manual
SIMPLICITY
*Queen (shown without mattress)
*Split Cal-King
LPAdjustableBases.com
CONTENTS
Advisory....................................................................................................................... 3
Acoustics..................................................................................................................... 5
Fabric Cleaning Information........................................................................................... 5
Installation.................................................................................................................. 6
Remote Control Function............................................................................................. 14
Remote Control Programming...................................................................................... 15
Troubleshooting.......................................................................................................... 19
Accessories................................................................................................................ 20
1-3-25 Warranty......................................................................................................... 21
If adjustable base does not operate or if parts are missing, call:
800-888-3078
Do not contact retail store or dealer.
ADVISORY
IMPORTANT INFORMATION
READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT
WARNING
FOR OPTIMUM ADJUSTABLE BASE
OPERATION, USE A GROUNDED, ELECTRICAL
SURGE PROTECTION DEVICE (NOT
INCLUDED). FAILURE TO USE A SURGE
PROTECTION DEVICE COULD COMPROMISE
SAFETY OR CAUSE PRODUCT MALFUNCTION.
ELECTRICAL RATING
Electrical components are rated for 100-120 volt,
60Hz, 100 watt.
ELECTRICAL GROUNDING
This product is equipped with a polarized or
grounded electrical power cord. The power cord will
only fit into a grounded, electrical surge protection
device (not included) or a grounded electrical outlet.
WARRANTY WARNING
Do not open any control boxes, motors or remote
control devices (with the exception of the remote
control and power down box battery compartments).
The product warranty will be void if these
components are tampered with. Do not attempt
to alter component wiring or adjust or modify the
structure of the product in any way or the warranty
will be void. Any repair or replacement of base parts
must be performed by authorized personnel.
LUBRICATION
This product is designed to be maintenance free.
The lift motors are permanently lubricated and
sealed—no additional lubrication is required. Do not
apply lubricant to lift motor lead screws or any nylon
nuts or the base may inadvertently creep downward
from the elevated position.
SERVICE REQUIREMENTS
Service technicians are not responsible for moving
furniture, removing headboards and footboards
or any items required to perform maintenance on
the base. In the event the technician is unable to
perform service due to lack of accessibility, the
service call will be billed to the purchaser and the
service will have to be rescheduled.
PRODUCT RATINGS
The base lift motors are not designed for continuous
use. Reliable operation and full life expectancy
will be realized as long as the lift motor operation
does not exceed 15% at maximum continuous
running of 2 minutes; maximum of 5 switching
cycles per minute. Note: Massage equipped
bases are not designed for continuous, extended
massage operation. Massage systems are rated
for a maximum of 2 hours of use within any 6
hour period. Any attempt to circumvent or exceed
product ratings will shorten the life expectancy of
the product and may void the warranty.
The recommended maximum weight (including
mattress) is 550 lb (249 kg) distributed evenly
across the base. This product is not designed to
support or lift this amount in the head or foot
sections alone. Note: Exceeding the recommended
weight restrictions could damage the base and void
the warranty.
For best performance, consumers should enter and
exit the adjustable base with the base in the flat
(horizontal) position. Avoid placing entire weight on
head or foot section of the base, including when in
the raised position. DO NOT STAND ON BASE AT
ANY TIME.
UL (Underwriters Laboratories) recognized
components.
CFR 1633 approved for use with most mattresses.
Assembled in USA.
Performance Models Simplicity Owners Manual 99301571-b
3
ADVISORY
IMPORTANT INFORMATION
READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT
SMALL CHILDREN / PETS WARNING
After the base is unboxed, immediately dispose
of packaging material as it can smother small
children and pets. To avoid injury, children or pets
should not be allowed to play under or on the base.
Children should not operate this base without adult
supervision.
PACEMAKER WARNING
This product produces a vibrating sensation.
It is possible that individuals with heart-assist
pacemakers may experience a sensation similar to
exercise. Consult physician for complete information.
HOSPITAL USE DISCLAIMER
This base is designed for in-home use only. It is
not approved for hospital use and does not comply
with hospital standards. Do not use this base with
tent type oxygen therapy equipment, or use near
explosive gases.
LOCKING CASTER SAFETY FEATURE
Many adjustable bases are equipped with locking
casters to prohibit the base from movement. For
best results, place rubber caster cups under locking
casters when the base is located on smooth or hard
surface flooring—it is possible for locking caster
equipped beds to slide without the use of rubber
caster cups.
To activate locking casters, push down on the lock
tab. To disengage the locking mechanism, push up
on the lock tab (see illustration below).
FCC COMPLIANCE
The equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment
is operated in a residential environment. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to radio
or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one
or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following conditions: (1)
This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
FCC Caution: Any changes or modifications not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate this equipment.
LOCKING CASTER
DETAIL
Radio Frequency = 2.4GHz.
CK
LO
4
Performance Models Simplicity Owners Manual 99301571-b
ACOUSTICS
LIFTING/LOWERING MECHANISMS
The lift/lower feature will emit a minimal
humming sound during operation. This is
normal.
During operation, the lift arm wheels make
contact with the platform support of the base.
This applies slight tension on the moving
components and resonance is reduced to a
minimum level. If excessive noise or vibration is
experienced, reverse the movement action (up or
down) of the base with the remote control. This
should realign the base’s activating mechanisms
to the proper operational position.
LOCATION ENVIRONMENT
The level of sound experienced during
operation is directly related to the location
environment. For example, when a base is
located on a hardwood floor with the massage
feature in operation, a vibrating tone will be
audible. To minimize this resonance, place a
piece of carpet, or rubber caster cups, under
each leg or caster of the base.
It is possible to experience vibration or noise
from the headboard brackets, headboards or
footboards if mounting bolts are not firmly
tightened.
MASSAGE OPERATION
The massage feature will emit a minimal tone
during operation. This is normal. When the
massage level is increased, motor resonance
will intensify accordingly.
FABRIC CLEANING INFORMATION
Spot clean only with water based shampoo
or foam upholstery cleaner. Pretest a small,
inconspicuous area before proceeding. Do
not over wet. Do not use solvents to spot
clean. Pile fabrics may require brushing with
a non-metallic, stiff bristle brush to restore
appearance. Hot water extraction or steam
cleaning is not a recommended cleaning
method.
To prevent overall soiling, frequent vacuuming
or light brushing with a non-metallic stiff
bristle brush to remove dust and grime is
recommended. When cleaning a spill, blot
immediately to remove spilled material. Clean
spots or stains from the outside to the middle
of the affected area to prevent circling. Use a
professional furniture cleaning service when an
overall soiled condition is apparent.
Performance Models Simplicity Owners Manual 99301571-b
5
INSTALLATION
For installation and setup, complete the following procedures, in the order indicated below
and on the following pages:
STEP 1
Before discarding any packing materials,
check the adjustable base shipping carton
and verify the following items are
included:
•
•
•
•
•
•
•
•
•
(1)
(4)
(4)
(1)
(3)
(1)
(1)
(1)
(1)
Mattress Retainer
Bed Legs
Locking Leg Casters
Remote Control
AAA Batteries
Power Down Box (batteries not included)
Owners Manual
Warranty Activation Card
Quick Setup Guide
OWNERS MANUAL
QUICK SETUP GUIDE
WARRANTY
ACTIVATION CARD
MATTRESS
RETAINER
(1 per base)
POWER DOWN BOX
(factory pre-installed to motor)
batteries not included
LEG
(4 pieces)
LOCKING LEG CASTER
(4 pieces)
(3) AAA BATTERIES
REMOTE CONTROL
6
Performance Models Simplicity Owners Manual 99301571-b
INSTALLATION
STEP 2
Remove the hardware box. Cut the zip-tie and
remove the mattress retainer.
WARNING
STEP 3
Install (4) legs into the base frame. Simply screw each leg
into a tapped hole at the corner of the base frame (FIGURE 1).
Insert casters into the bottom of each bed leg.
FIGURE 1
AT LEAST TWO PEOPLE ARE
RECOMMENDED FOR HANDLING AND
MOVING ADJUSTABLE BASE.
CAUTION
CAUTION
CASTERS – PRESS-FIT
INTO BOTTOM OF LEGS
(IF APPLICABLE)
DO NOT ATTEMPT TO SCREW
LEGS INTO ANY OTHER INSERTS.
THIS WILL DAMAGE PRODUCT.
LEGS – SCREW INTO
TAPPED HOLE AT
EACH CORNER
STEP 4
Carefully lift the adjustable base from the shipping carton,
keeping the unit top-side-down. Remove and extend out
power cord from base.
WARNING
POWER CORDS MUST NOT INTERFERE WITH
ANY ADJUSTABLE BASE MECHANISMS.
STEP 5
Remove the plastic packaging from the base frame. Carefully
rotate the adjustable base over to position the base so it is
resting on its legs.
Performance Models Simplicity Owners Manual 99301571-b
7
INSTALLATION
STEP 6
Plug electrical power cord into a working, grounded electrical outlet.
Note: An electrical surge protection device is recommended (not included).
STEP 7
Install batteries in remote control (3-AAA, included) (FIGURE 2). Note:
Make sure batteries are properly oriented. Briefly activate all functions of the
base with the remote control to verify all features are in working order. If
base does not operate, refer to the Troubleshooting section of this manual.
NEGATIVE (-)
END
FIGURE 2
TABS
BATTERY
COMPARTMENT
DOOR
POSITIVE (+)
END
PRESS IN ON TAB AND LIFT OUT TO
REMOVE BATTERY COMPARTMENT
DOOR. INSERT TABS IN TAB SLOTS
AND SNAP IN TO REPLACE.
STEP 8
Return base to the level position.
8
Performance Models Simplicity Owners Manual 99301571-b
BOTTOM
OF REMOTE
CONTROL
INSTALLATION
STEP 9
Install mattress retainer at the foot end of the adjustable base as follows:
a. Locate grommeted holes at foot end of base.
b. Place mattress retainer ends into grommeted holes in top surface
of adjustable base (FIGURE 3). Press down until horizontal retainer
section is flush against base.
FIGURE 3
MATTRESS
RETAINER
FO
OT
EN
DO
FB
AS
E
NOTE: If base is to be set up without a headboard, install
mattress to complete basic installation. If headboard
is to be installed, proceed to Headboard Bracket
Installation. (Headboard Bracket sold as accessory.)
Performance Models Simplicity Owners Manual 99301571-b
9
INSTALLATION
HEADBOARD BRACKET INSTALLATION (optional accessory)
Install headboard brackets to the base frame. When attaching (2) twin size
units to a king size headboard an optional swing hinge kit (see accessory
section) may be used to connect the twin units.
NOTE
WARNING
FAILURE TO FOLLOW HEADBOARD BRACKET
INSTALLATION INSTRUCTIONS MAY CAUSE
HEADBOARD BRACKET INTERFERENCE WITH
BASE FOAM DURING BASE OPERATION.
BASE FOAM OR BASE COVER DAMAGE
COULD RESULT.
IN ORDER TO AVOID A PERSON OR PET
BEING CAUGHT IN THE SPACE REFERENCED
BELOW WHILE THE BED IS IN MOTION,
THE BOTTOM OF THE HEADBOARD CROSS
MEMBER MUST BE POSITIONED SO THAT
THERE IS NO MORE THAN 3 INCHES
(76.2MM) BETWEEN THE HEADBOARD AND
THE TOP OF THE MATTRESS (FIGURE 4). DO
NOT EXCEED 3 INCHES (76.2MM). FAILURE
TO FOLLOW THIS INSTRUCTION COULD
RESULT IN SERIOUS PERSONAL INJURY OR
DEATH.
FIGURE 4
X.
A
sM
he
nc
3i
Headboard cross member location
must not exceed 3 inches (76.2mm)
from the top of the mattress.
10
Performance Models Simplicity Owners Manual 99301571-b
INSTALLATION
STEP 10
Install headboard brackets to the base frame as follows:
a. Raise the head section of the base (with remote control) to gain access
to the base frame.
b. Locate channel connector kit (FIGURE 5). On one side of base frame,
locate (2) holes for channel connector mounting (FIGURE 6).
c. Position channel connector so that the flat side is flush against base
frame. Attach channel connector to base frame using (2) 1½ inch long
hex head bolts/nuts (FIGURE 6). Tighten bolts. Note: For units with
74” base length, use inner mounting holes. For units with 80” base
length, use outer mounting holes (FIGURES 5 and 6).
FIGURE 5
80” BASE
LENGTH
MOUNTING
HOLES
74” BASE
LENGTH
MOUNTING
HOLES
FIGURE 6
74” BASE
LENGTH
MOUNTING
HOLES
(2) 1-1/2 INCH LONG
HEX HEAD BOLTS/NUTS
Performance Models Simplicity Owners Manual 99301571-b
11
INSTALLATION
d. Using (2) 3 inch long carriage bolts/nuts, attach (1) headboard
bracket channel to (1) channel connector (FIGURE 7). Hand tighten
bolts/nuts (loosely) to allow adjustment of the headboard bracket
channels.
FIGURE 7
USE (2) 3 INCH LONG CARRIAGE
BOLTS TO ATTACH HEADBOARD
BRACKET CHANNEL TO BASE FRAME
HEADBOARD
BRACKET
CHANNEL
(queen size
shown)
SLIDE BRACKET
ASSEMBLIES IN OR
OUT TO ACHIEVE
POSITION
e. Attach (1) headboard bracket flange to one of the bracket channels
with (2) 1 inch long hex head bolts/nuts (FIGURE 8). Tighten bolts.
f. Repeat procedure to attach the other headboard bracket.
FIGURE 8
USE (2) 1 INCH LONG HEX
HEAD BOLTS TO ATTACH
HEADBOARD BRACKET
FLANGE TO BRACKET
CHANNEL
ADJUST AS
REQUIRED TO
ACHIEVE POSITION
12
Performance Models Simplicity Owners Manual 99301571-b
HEADBOARD
BRACKET
FLANGE
INSTALLATION
g.When installing a headboard, footboard, or four-piece surround (case
good), allow for 1.5 inches (38.1mm) to 2 inches (50.8mm) of
clearance at the head and foot of the bed and a minimum of ½ inch
to ¾ inch on the sides.
h.Firmly tighten the 3 inch carriage bolts of both headboard bracket
channels.
i. Measure the distance (center-to-center) between the mounting holes
in the headboard.
j. Measure the center-to-center distance between the mounting slots of
the headboard bracket flanges.
k.If bracket flange adjustment is required to accept the headboard,
remove the 1 inch headboard bracket flange bolts and move flanges
side-to-side for the adjustment. Reinstall bolts and tighten.
l. Install headboard.
STEP 11
Install mattress on adjustable base.
Typical Simplicity adjustable base installation is now complete.
Performance Models Simplicity Owners Manual 99301571-b
13
POWER DOWN OPERATION
To lower the base to the flat position during an electrical power outage, complete the following procedure:
STEP 1
Locate (1) power down box (FIGURE 9). Install (2) 9 volt batteries
(included) in power down box (FIGURE 9).
FIGURE 9
POWER
DOWN BOX
LOWERING
BUTTON
INSTALL (2) 9
BOLT BATTERIES
STEP 2
Press the lowering button on the power down box (FIGURE 9) to
lower the base to the flat position.
STEP 3
Remove two (2) 9 volt batteries from power down box. When power
is restored from outage, base is ready to resume normal operation.
14
Performance Models Simplicity Owners Manual 99301571-b
REMOTE CONTROL FUNCTION
HEAD UP BUTTON
Press and hold to raise the head section.
FOOT UP BUTTON
Press and hold to raise the foot section.
HEAD DOWN BUTTON
Press and hold to lower the head section.
FOOT DOWN BUTTON
Press and hold to lower the foot section.
CUST 1 BUTTON
Press and hold to adjust base to the
programmed position.
*To program a position, adjust base to
desired position, press and hold the set
button until the massage motors turn on
and off, then press and hold the Cust 1
button until the massage motors turn on
and off.
SET BUTTON
Press and hold to program Cust 1 and Cust
2 presets.
FLAT BUTTON
Press and hold to lower the base to the
level position.
FOOT MASSAGE UP BUTTON
Press to increase massage intensity.
Massage has 3 speeds: Low, medium, and
high. Massage will automatically shut off
after 15 minutes.
CUST 2 BUTTON
Press and hold to adjust base to the
programmed position.
*To program a position, adjust base to
desired position, press and hold the set
button until the massage motors turn on
and off, then press and hold the Cust 2
button until the massage motors turn on
and off.
MASSAGE ON/OFF BUTTON
Press to turn both massage motors on or off.
FOOT MASSAGE DOWN BUTTON
Press to decrease massage intensity.
Massage has 3 speeds: Low, medium, and
high. Massage will automatically shut off
after 15 minutes.
HEAD MASSAGE UP BUTTON
Press to increase massage intensity.
Massage has 3 speeds: Low, medium
and high. Massage will automatically
shut off after 15 minutes.
NOTE
HEAD MASSAGE DOWN BUTTON
Press to decrease massage intensity.
Massage has 3 speeds: Low, medium
and high. Massage will automatically
shut off after 15 minutes.
MASSAGE SETTINGS CANNOT
BE SAVED IN PRESET CUST 1
AND CUST 2 BUTTONS.
NOTE
REMOTE CONTROL REQUIRES THREE (3) AAA SIZE BATTERIES (INCLUDED). THE BUTTONS ON
THE REMOTE CONTROL ILLUMINATE FOR 2.5 SECONDS WHEN PRESSED AND RELEASED.
PRESS & HOLD TO ONE TOUCH
Note: If using 2 remotes to operate 1 or more bases, both remotes must be set to the same “press & hold” or “press & touch” mode.
To change remote control functions from “press and hold” to “one touch”, simultaneously press the HEAD MASSAGE DOWN and
FOOT MASSAGE DOWN buttons. The massage motor will turn on and off confirming the change. Your base is now set to “one touch.”
When in “one touch” mode:
Cust 1 and Cust 2 buttons
One touch button. Base will adjust to the programmed position. Press any other button to stop the base during movement.
Flat button
One touch button. Base will shut off massage motor, if active, and adjust base to level position. Press any other button to stop
the base during movement.
To revert back to factory settings, simultaneously press and hold the SET button and the FLAT button. The massage motor
will turn on and off confirming the change. Your base is now set to factory settings. Note: Cust 1 and Cust 2 positions will
revert to factory preprogrammed positions.
Performance Models Simplicity Owners Manual 99301571-b
15
REMOTE CONTROL PROGRAMMING (1 remote control - 1 base)
Program One Remote to Operate One Base - perform the
following numbered procedure.
STEP 1
Plug adjustable base into electrical power source.
Position base on its side. Locate the power
down box, attached to the underside of the base
(FIGURE 9).
STEP 2
Push the power down reset button in two times
in rapid succession. Then, the reset light will
light up (FIGURE 9).
HEAD UP
BUTTON
FIGURE 9
MOTOR
attached to
underside
of adjustable base
FLAT
BUTTON
RESET
BUTTON
RESET LIGHT
POWER DOWN
DEVICE
factory pre-wired
to motor
FIGURE 10
STEP 3
On the remote control, simultaneously press
and hold the HEAD UP and FLAT buttons
(FIGURE 10) until the indicator light goes off on
the control box.
One remote control is now programmed to
operate one base.
16
Performance Models Simplicity Owners Manual 99301571-b
REMOTE CONTROL PROGRAMMING (1 or 2 remote controls - 2 bases)
Program One or Two Remotes to Operate Two Basesperform the following numbered procedure. Note: Make
sure both remotes are in “press & hold” mode and both
bases are flat before beginning procedure. IF USING 2
BASE 1
REMOTES TO OPERATE 1 OR MORE BASES, BOTH REMOTES
MUST BE IN THE SAME “PRESS & HOLD” OR “PRESS &
RELEASE” MODE FOR FLAT OR PROGRAMMABLE BUTTONS
TO FUNCTION.
STEP 1
Plug both adjustable bases into electrical power source.
Operate both remote controls to verify each remote
functions properly with its respective base. NOTE: See
1-to-1 programming procedure if bases do not operate.
Using remote controls, adjust both bases to flat position.
Unplug both bases from electrical power source.
OR
REMOTE 1
REMOTE 2
BASE 2
FIGURE 12
RESET MFP
PORT PORT
STEP 2
MASSAGE
PORT
Choose base 1 remote. Retain base 2 remote control as a spare
or use if 2 remotes are desired to operate both bases.
STEP 3
Position both bases on their sides, in close proximity
to each other. CAUTION: AT LEAST TWO PEOPLE
ARE RECOMMENDED FOR HANDLING AND MOVING
ADJUSTABLE BASE.
remove power
down device and
insert male
plug here
STEP 4
Locate control box on both bases and unplug both power
down devices from MFP port.
STEP 5
Locate dual sync cable (FIGURE 11). Insert one power down
cord male plug into one female plug of dual sync cable.
CONTROL BOX 1
attached to underside
of adjustable base 1
FIGURE 13
RESET MFP
PORT PORT
MASSAGE
PORT
FIGURE 11
DUAL SYNC
CABLE
FEMALE PLUG
MALE PLUGS
remove power
down device and
insert male
plug here
FEMALE PLUG
STEP 6
Insert one male plug of dual sync cable into the MFP port
of control box of base 1 (FIGURE 12).
STEP 7
Insert the other power down cord male plug into the other
female plug of dual sync cable. Insert the other male plug
of dual sync cable into the MFP port of control box of
base 2 (FIGURE 13).
STEP 8
Turn both bases over so they are resting on their legs.
CAUTION: MAKE SURE CABLE IS CLEAR OF BASE AND
FREE OF ANY PINCH POINTS.
CONTROL BOX 2
attached to underside
of adjustable base 2
STEP 9
Plug both bases into electrical power source. Operate both
bases with either one or both remote controls. NOTE: If
bases do not operate in unison with either of the remotes,
verify dual sync cable connections are fully seated at both
control boxes.
Performance Models Simplicity Owners Manual 99301571-b
17
“PRESS & HOLD” TO “ONE TOUCH” PROGRAMMING (1 or 2 remote controls - 2 bases)
TO CHANGE FROM “PRESS & HOLD” TO “ONE TOUCH” PROGRAMMING
STEP 1
Adjust base to the flat position.
STEP 2
Simultaneously press the HEAD MASSAGE DOWN and FOOT MASSAGE DOWN buttons on either of the remote
controls. The massage motors will turn on and off confirming the change.
WHEN IN “ONE TOUCH” MODE:
Cust 1 and Cust 2 buttons
One touch button. Base will adjust to the programmed position. Press any other button to stop the base during
movement.
Flat button
One touch button. Base will shut off massage motor, if active, and adjust base to level position. Press any other
button to stop the base during movement.
REVERT BACK TO FACTORY SETTINGS
To revert back to factory settings, simultaneously press and hold the SET button and the FLAT button on either
of the remote controls.. The massage motor will turn on and off confirming the change. Your base is now set to
factory settings.
NOTE
WHEN OPERATING 2 REMOTE CONTROLS,
MAKE SURE BOTH REMOTES ARE IN “PRESS
& HOLD” MODE AND BOTH BASES ARE FLAT
BEFORE BEGINNING PROCEDURE.
NOTE: IF USING 2 REMOTES TO OPERATE 1 OR
MORE BASES, BOTH REMOTES MUST BE SET
TO THE SAME “PRESS & HOLD” OR “PRESS &
TOUCH” MODE.
18
Performance Models Simplicity Owners Manual 99301571-b
REMOTE CONTROL PROGRAMMING (separating 2 bases)
Separate Two Bases - for independent adjustable base movement,
perform the following numbered procedure.
STEP 1
Unplug both bases from electrical power outlet. Position
both bases on their sides, in close proximity to each other.
CAUTION: AT LEAST TWO PEOPLE ARE RECOMMENDED
FOR HANDLING AND MOVING ADJUSTABLE BASE.
BASE 1
REMOTE CONTROL 1
STEP 2
Locate control box on both bases. Locate dual sync cable
plugged into the MFP port of both bases.
STEP 3
Remove the male plug of dual sync cable from the MFP
port of control box of both bases (FIGURE 14). Plug
power down devices into the MFP port of the control
boxes of both bases.
BASE 2
REMOTE CONTROL 2
FIGURE 15
MOTOR
attached to
underside
of adjustable base
FIGURE 14
RESET MFP
PORT PORT
MASSAGE
PORT
RESET
BUTTON
RESET LIGHT
remove the male plug
from both control boxes
and plug in power down
devices
POWER DOWN
DEVICE
factory pre-wired
to motor
CONTROL BOX
attached to underside
of both adjustable bases
STEP 4
Plug base 1 into electrical power outlet. On the power down
box for base 1, push the reset button in two times in rapid
succession. Then, the reset light will light up (FIGURE 15).
STEP 5
On remote control 1, simultaneously press and hold the
head up and flat buttons (FIGURE 16) until the reset light
goes off on the power down box.
STEP 6
Repeat Steps 4 & 5 with base 2 and remote control 2.
STEP 7
Turn both bases over so they are resting on their legs.
CAUTION: AT LEAST TWO PEOPLE ARE RECOMMENDED
FOR HANDLING AND MOVING ADJUSTABLE BASE.
HEAD UP
BUTTON
FLAT
BUTTON
Independent remote control operation is now
restored (remote control 1 operating base 1; remote
control 2 operating base 2).
FIGURE 16
Performance Models Simplicity Owners Manual 99301571-b
19
TROUBLESHOOTING
If the adjustable base fails to operate, investigate the symptoms and possible solutions
provided in the chart below:
SYMPTOM
Remote control illuminates and appears to be
operable, but will not activate base.
SOLUTION
• Verify power cord is plugged into a working, grounded
electrical outlet. A grounded, electrical surge protection
device is recommended. Test outlet by plugging in
another working appliance.
• If the base was operated over the rated duty cycle,
thermal switch opens. Wait 30 minutes before trying
to operate the base. Once the base resumes normal
operation, do not exceed the duty cycle.
• Program the remote control (see Remote Control
Programming section of this manual for programming
procedures).
No features of the base will activate.
• Unplug power cord, wait 30 seconds and plug in to
reset electronic components.
• Electrical circuit breaker may be tripped. Check
electrical service breaker box to verify.
• Defective surge protection device or electrical outlet.
Test outlet by plugging in another working appliance.
Remote control will not illuminate.
• Replace batteries in the remote control.
• Base mechanism may be obstructed. Elevate base and
check for obstruction. Remove obstruction.
Head or foot section will elevate, but will not
return to the horizontal (flat) position.
• Head section may be too close to the wall.
• Headboard may be too close the edge of the mattress.
Verify a 1.5” (38.1mm) to 2” (50.8mm) distance
between headboard brackets and mattress. Adjust if
required.
• Verify headboard brackets were removed during
installation. Remove headboard brackets if still
attached to the underneath side of base.
• If base is located on hard surface flooring, place carpet
pieces or rubber caster cups under each leg or caster
of the base. (See accessory page for rubber caster cup
order information.)
Excessive massage motor noise.
• Elevate the head or foot section a short distance (with
the remote control) to realign the lift/lower mechanisms
with the bed support platform.
• Verify that the base is not positioned against a wall,
nightstand, or other object that may cause vibration or
noise.
• If base is installed over a bed frame, verify massage
motors are not causing bed frame (or bed frame
components) to vibrate.
• Verify that headboard attachment hardware is tightened
firmly (if used).
20
Performance Models Simplicity Owners Manual 99301571-b
ACCESSORIES
OPTIONAL EQUIPMENT
Contact customer service toll free (800-888-3078) to order the accessories indicated in the chart
below.
ACCESSORY DESCRIPTION
CODE
Head Board Brackets-TXL
4B6117
Head Board Brackets-FXL/Q
4B6118
Push-in Locking Casters
Bed Link Kit
(set of 4)
(connects two bases together)
IMAGE
4B1806
4B7410
Rubber Caster Cups (set of 4)
4B1034
4” Legs (set of 4)
4B1833
5” Legs (set fo 4)
4B2100
7” Legs (set of 4)
4B2101
Performance Models Simplicity Owners Manual 99301571-b
21
1 YEAR, 3 YEAR AND 25 YEAR LIMITED WARRANTY
In this warranty: “Adjustable base” means the adjustable bed foundation sold by L&P to the dealer. The “adjustable
base” does not include the mattress. “L&P” means Leggett & Platt, Incorporated. “Purchaser” and “You” both mean the
consumer who is the original purchaser of this adjustable base made by L&P. This warranty is not transferrable. “Warranty
Commencement Date” means either (i) the date You purchased a new and unused L&P adjustable base or (ii) the date of
manufacture of this adjustable base if You purchased an L&P adjustable base that has been used as floor or display model.
L&P warrants this adjustable base to You on the terms and over the reducing periods of time set out below. All warranty claims
require notice from You to be given to L&P in the manner set out below, and to be received by L&P inside the applicable
warranty time period.
1ST YEAR FULL WARRANTY
For the first year from the Warranty Commencement Date,
your adjustable base is warranted against non-excluded
defects in L&P’s workmanship or materials. During the
first year from the Warranty Commencement Date, L&P
will repair or replace (at no cost to You) any defective
adjustable base part, and L&P will pay all authorized labor
and transportation costs associated with the repair or
replacement of any parts found to be defective.
2ND & 3RD YEAR LIMITED WARRANTY
During the second and third year from the Warranty
Commencement Date, L&P will replace any adjustable
base part found to be defective and not excluded by
this warranty. You are responsible to pay all service and
transportation costs related to the costs of receiving and
installation of the new part.
4TH YEAR TO END OF 25TH YEAR LIMITED WARRANTY
Starting in the fourth year from the Warranty
Commencement Date and through to the end of the 25th
year from the Warranty Commencement Date, L&P will
replace steel and mechanical base parts found to be
defective and not excluded by this warranty. This warranty
does not cover any electronics, electrical components,
drive motors or massage motors. You are responsible
to pay all service and transportation costs related to
receiving and installation of the new part and a portion
of the cost of the replacement steel and mechanical
part, based on the number of months that the base has
been owned by you since the fourth anniversary of the
Warranty Commencement Date. By the end of the 25th
year, no portion of the replacement cost is covered by
L&P. You will be required to pay 1/22nd of the then
current replacement cost of the part multiplied by the
number of years past the third year from the Warranty
Commencement Date. This portion is calculated using the
following formula: Cost of the part divided by 22 [being
the number of years in years 4 to 25 inclusive], multiplied
by the number of years you have owned the base since
the end of the first 3 years. For example, if you make a
claim for a part eligible for this warranty in the 5th year
since the Warranty Commencement Date, you would be
responsible for paying: $100 part cost divided by 22,
multiplied by 2 = $9.09.
22
Performance Models Simplicity Owners Manual 99301571-b
ADDITIONAL TERMS AND CONDITIONS
This warranty requires notice to be given to L&P of any
claim for repairs or replacement parts.
EXCLUSIONS:
This warranty does not apply; (a) to any damage caused
by You; (b) if there has been any repair or replacement
of adjustable base parts by an unauthorized person; (c)
if the adjustable base has been mishandled (whether
in transit or by other means), subjected to physical or
electrical abuse or misuse, or otherwise operated in any
manner inconsistent with the operation and maintenance
procedures outlined in the Owner’s Manual and this
warranty; (d) to damage to mattresses, fabric, cables,
electrical cords or items supplied by dealers (contact the
dealer for warranty information on these items); (e) if
there has been any modification of the adjustable base
without prior written consent by L&P; or (f) to costs for
unnecessary service calls, including costs for in-home
service calls solely for the purpose of educating You
about the adjustable base or finding a satisfactory power
connection.
This warranty will be void if either the recommended
weight restriction is not followed (refer to the advisory
section of the Owner’s Manual) or if You sell or give or
transfer the base to another person.
Any repairs to or replacement to Your adjustable base or
its components under the terms of this limited warranty
does not extend the applicable warranty from the Warranty
Commencement Date. This time limitation may not apply
in some jurisdictions, including the Province of Quebec.
The decision to repair or to replace defective parts under
this warranty shall be made, or cause to be made, by L&P
at its option and in its sole discretion.
Continued on next page...
1 YEAR, 3 YEAR AND 25 YEAR LIMITED WARRANTY
Repair or replacement shall be the sole remedy of the
Purchaser. There shall be no liability on the part of L&P
for any special, indirect, incidental, or consequential
damages or for any other damage, claim, or loss not
expressly covered by the terms of this warranty.
This limited warranty does not include reimbursement for
inconvenience, removal, installation, setup time, loss of
use, shipping, or any other costs or expenses. L&P and
its service technicians will not be responsible for moving
furniture or any other items not attached to the adjustable
base in order to perform service on the adjustable base.
It is the sole responsibility of You to provide adequate
space and accessibility to the adjustable base. In the
event that the technician is unable to perform service due
to lack of accessibility, the service call will be billed to
You and the service will have to be rescheduled.
L&P makes no other warranty whatever, express or
implied, and all implied warranties of merchantability and
fitness for a particular purpose are disclaimed by L&P and
excluded from this agreement.
Some American States do not allow the exclusion or
limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to You.
This warranty gives You specific legal rights, and You may
also have other rights, which may vary from jurisdiction
to jurisdiction. This warranty is valid in all 50 American
States, the District of Columbia, Puerto Rico, and all 10
Provinces and 3 Territories of Canada.
For customer service under this limited warranty, give
notice to L&P by mail, phone, email or online to the
addresses set out below:
Leggett & Platt, Incorporated
PO Box 668
Lexington, North Carolina 27293
toll free phone: 1.800.888.3078
online: lpadjustablebases.com
email: accustomerservice@leggett.com
PLEASE DO NOT CONTACT YOUR RETAIL DEALER
OR ANY OTHER SERVICE PERSONNEL
Performance Models Simplicity Owners Manual 99301571-b
23
99301571-b EDR13563 6/16
NATIONWIDE CUSTOMER SERVICE toll free: (800) 888-3078
© 2016 Leggett & Platt Adjustable Bed Group, a division of Leggett & Platt Incorporated