SUBMITTAL DATA: MSZ-FH12NA & MUZ-FH12NA
M-SERIES
12,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM
Job Name:
System Reference:
Date:
Electrical Power
Requirements
Minimum Circuit Ampacity (MCA)
Indoor Unit: MSZ-FH12NA
Wireless Remote Controller
Outdoor Unit: MUZ-FH12NA
Indoor Unit
□□ Condensate Pump (BlueDiamond X87-711/721; 115/230V)
□□ Condensate Pump (Sauermann SI30-115/230; 115/230V)
□□ Replacement Platinum Deodorizing Filter (MAC-3000FT-E)
□□ Replacement Anti-allergy Enzyme Filter (MAC-2330FT-E)
Outdoor Unit
1 / 11
Blower Motor (ECM)
F.L.A.
0.67
Blower Motor Output
W
30
Indoor Unit
Field Drainpipe Size O.D.
5/8 (15)
DC INVERTER-driven Twin Rotary
Fan Motor (ECM)
□□ Wireless Controller (MHK1)
□□ Wired Remote Controller PAR-31MAA (Requires MAC-333IF-E)
□□ Wireless Interface for kumo cloud™ (PAC-WHS01WF-E)
□□ Thermostat Interface (PAC-US444CN-1)
SPECIFICATIONS:
Cooling1
Btu/h / W
12,000 / 870
Heating at 47º F2
Btu/h / W
13,600 / 950
Capacity Range
F.L.A.
0.50
Airflow Rate (Lo - Med - Hi - Super Hi - Powerful)
Indoor
(Cooling)
Indoor
(Heating)
Rated Conditions (Capacity / Input)
137-167-221-304-398
DRY
117-143-190-261-342
WET
DRY
CFM
140-167-225-325-454
1,190 / 1,320
Outdoor
Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful)
Minimum
Maximum
Cooling1
Btu/h
2,500
13,600
Heating at 47º F2
Btu/h
3,700
21,000
Heating at 17º F3
Btu/h
-
13,600
Heating at 5º F4
Btu/h
-
13,600
1. Cooling | Indoor: 80º F(27º C)DB / 67º F(19º C)WB; Outdoor: 95º F(35º C)DB / 75º F(24º C)WB*
2. Heating at 47ºF | Indoor: 70º F (21º C)DB / 60º F (16º C)WB; Outdoor: 47º F (8º C)DB / 43º F (6º C)WB*
3. Heating at 17º F | Indoor: 70º F(21º C)DB / 60º F(16º C)WB; Outdoor: 17º F(-8º C)DB / 15º F(-9º C)WB*
4. Heating at 5º F | Indoor: 70º F (21º C)DB / 60º F(16º C)WB; Outdoor: 5º F(-15º C) DB / 5º F(-15º C)WB
* Rating Conditions per AHRI Standard
Operating Conditons (Indoor Intake Air Temp.) (Max./ Min.)
Cooling5
90º F (32º C) DB / 67º F (19º C) DB
Heating
80º F (27º C) DB / 70º F (21º C) DB
Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.)
Cooling5
115º F (46º C) DB / 14º F (-10º C) DB
Heating
75º F (24º C) DB / -13º F (-25º C) DB**
Applications should be restricted to comfort cooling only; equipment cooling applications are not
recommended for low ambient temperature conditions.
**
System cuts out at -18º F (-28º C) to avoid thermistor error and automatically restarts at -14º F (-26º C).
5
AHRI Efficiency Ratings
Indoor
Outdoor
21-24-29-36-41
Cooling
Heating
Cooling
dB(A)
21-24-29-36-42
49
51
Heating
External Dimensions
Indoor (H x W x D)
In.(mm)
Outdoor (H x W x D)
12 + 11/16 x 36-7/16 x 9-3/16
(305 +17 x 925 x 234)
21-5/8 x 31-1/2 x 11-1/4
(550 x 800 x 285)
Net Weight
Indoor
Outdoor
Lbs.(kg)
29 (12)
83 (38)
External Finish
Indoor
Munsell 1.0Y 9.2 / 0.2
Outdoor
Munsell No. 3Y 7.8 / 1.1
Refrigerant
R410A ; 2 lb. 9 oz.
Refrigerant Piping (Flared)
26.1
Liquid (High Pressure)
12.5
Gas (Low Pressure)
Max. Total Refrigerant
Pipe Length (Height Diff.)
COP at
47o
F
4.2
COP at
17o
F
3.34
®
In.(mm)
Compressor
Controls
HSPF
0.83 / 1.9 pt./h
SHF / Moisture Removal
Outdoor Unit
□□ Base Pan Heater (MAC-640BH-U)
□□ Drain Socket (MAC-860DS)
Energy Star
A
Indoor / Outdoor
ACCESSORIES:
SEER
208 / 230V, 1-Phase, 60 Hz
Yes
Max. Total Refrigerant
Pipe Length (Length.)
In.(mm)
1/4 (6.35)
3/8 (9.52)
40 (12)
Ft. (m)
65 (20)
ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.
Specifications are subject to change without notice.
© 2016 Mitsubishi Electric US, Inc.
4
OUTLINES AND DIMENSIONS
7/16 × 1-1/16 Oblong hole
Indoor unit
2-5/8
6-3/4
15-9/16
14-11/16
10-1/8
3-9/16
Wall hole Ø3
Air in
9-3/16
2-3/8
2
1-9/16
27-11/16
4
6-5/16
11/16
2-3/16
1
2
Piping
1/4
11/16
9-5/8
3-15/16
Installation plate
2-5/8
11-3/4
3/8
8-1/8
3/16
12
4-1/16
7/8
8-7/8
8-1/2
3/8
9-5/16
10-3/16
35-5/8
1-7/8
36-7/16
8-7/8
9-1/4
7/16 × 13/16 Oblong hole
Installation plate
4-1/16
2-3/8
Unit: inch
Unit: mm (in.)
8-1/2
MSZ-FH12NA
MUZ-FH12NA
1-7/8
DIMENSIONS:
MSZ-FH12NA &
MSZ-FH09NA MSZ-FH12NA
MSZ-FH15NA
Drain hose
4-5/8
Air out
2
7-5/8
2
5-3/16
2-5/8
4
2-11/16
OUTLINES AND DIMENSIONS
MUZ-FH09NA
MUZ-FH09NAH MUZ-FH12NA MUZ-FH12NAH
(MSZ-FH15NA)
(MSZ-FH09/12NA)
Unit: mm (in.)
REQUIRED SPACE Insulation Ø1-7/16 O.D
moreline
whenØ1/4 15-3/8 (Flared connection Ø1/4)
Ø1/4 15-3/8 (Flared connection Ø1/4) *1 4 in. (100 mm) orLiquid
front and sides of the unit are clear
Ø3/8 13-3/8 (Flared connection Ø3/8)
Gas line
Ø3/8 13-3/8 (Flared connection Ø1/2)
Inslation Ø1-1/8 Connected part Ø5/8 O.D
Drain hose
Inslation Ø1-1/8 Connected
part Ø5/8 O.D
m)
clear *1
Liquid line
Gas line
Drain hose
Piping
Piping
MUZ-FH12NA
Insulation Ø1-7/16 O.D
Unit: inch
0m
(10 ore
n.
4 i or m
4 in
.(
or 100 m
mo
re m)
)
mm
00
. (2 e *2
8 in r mor
o
14
in.
(
or m350 m
ore m)
*2 When any 2 sides of left, right
and rear of the unit are clear
holes
Liquid refrigerant pipe joint
Refrigerant pipe (flared) Ø 1/4
Gas refrigerant pipe joint
Refrigerant pipe (flared) Ø 3/8
OBH683_DRAFT
DRAFT6
1340 Satellite Boulevard. Suwanee, GA 30024
Toll Free: 800-433-4822 www.mehvac.com
FORM# MSZ-FH12NA ~ MUZ-FH12NA - 201603
Specifications are subject to change without notice.
© 2016 Mitsubishi Electric US, Inc.
Download PDF