Book1 - House of rental

Book1 - House of rental
DRICAL
Owner's Manual - DrizAir®
Dehumidfiers
115v Models: 1200, 2000, 2400
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA USA 98233
Fax: (360) 757-7950 Phone US: (360) 757-7776
www dn-eaz com
07-01486 А 04-04 Copyright 2004 Dri-Eaz Products, Inc.
Owner's Manual
Dri-Eaz DrizAir® Dehumidfiers
115-volt models: 1200, 2000, 2400
READ AND SAVE THESE INSTRUCTIONS
A WARNING
ik “
FIRE AND ELECTRIC SHOCK
HAZARD
Unit must be electrically grounded.
Insert 3- prong plug on power cord
directly into matching grounded
receptacle.
«Do not use adaptor
Keep winng and motor dry.
«Do not operate in standing water
«Do not operate in rain or snow.
«If electrical components become
wet, allow them to dry before
using.
Read and understand manual
before use.
Use a 115V, 3-prong
grounded connection
07-01480 А 04-04 Copyright 2004 Dri-Eaz Products, Inc.
Do not use with an
adapter
Use and Operation
INTRODUCTION
DrizAir dehumidifiers reduce humidity in enclosed structural environments
by removing water vapor from the air. With proper use, DrizAir dehumidifiers
can help dry wet materials like carpet, carpet pad, floors, walls, building con-
tents and more. Using DrizAir dehumidifiers may also prevent secondary
damage caused by high humidity.
For best results, we recommend you use DrzAir dehumidifiers with Dn-Eaz
TurboDryer airmovers. The airmovers speed evaporation by lifting moisture
into the air.
How THE DRIZAIR DEHUMIDIFER Works
DrizAir refrigerant dehumidifiers operate by pulling moist air in across a very
cold evaporator core. The moisture condenses (freezes) on the coil. At inter-
vals, the machine will go into defrost mode, warming the frost back to water.
The water collects in a tray and leaves the unit through a drain hose or
pump.
IMPORTANT: Before moving the unit, make sure there's no water in the pump.
See how to use the PURGE function under “How to use the touchpad con-
troller” on page 3.
SETTING UP A DRYING AREA
Use in an enclosed space
You should operate DrizAir dehumidifiers in an enclosed area, as this cre-
ates a drying chamber. Close all doors, windows or areas that open to the
outside to maximize the unit's water removal efficiency. Also, keep traffic
though the drying chamber to a minimum.
How to position the DrizAir dehumidifier
- Place your DrizAir dehumidifier in the middle of a room away from walls
and contents
- Keep it away from anything that could prevent airflow into and out of the
unit.
Le
lllustration of proper dehumidifier placement
READ AND SAVE THESE INSTRUCTIONS
CAUTION
Do not operate DrizAir dehumidifiers at temperatures above 90°F (32°C). This can
cause damage to both the machine and the structure's contents. Over-dried materi-
als (especially wood products) may crack, shrivel, or discolor. Use of a dehumidifier
in high-heat conditions will reduce its efficiency and the life of the machine.
Managing temperature rise
DrizAir dehumidifiers warm the air as they remove moisture. Optimal drying
temperatures range from 68-85°F (20-29°C).
The most accurate way to monitor temperature is with a thermo-hygrometer,
however, you can use an indoor/outdoor thermometer to gauge temperature
just make sure it's located in the center of the room away from the airflow of
the dehumidifier.
If the temperature rises to unsafe levels (over 90°F/32°C) you can use the
structure's HVAC (air conditioning) system to bring the temperature down.
Just set it to 80°F (27°C), and continue to operate the dehumidifier. If
there's no HVAC system, call a Dri-Eaz at 888-867-3235, and a Technical
Specialist help you find an appropriate solution.
OPERATING YOUR DRIZAIR DEHUMIDIFIER
Setup
Place dehumidifier upright. If you transport a DrizAir dehumidifier in a hori-
zontal position, set it upright (vertical) for at least 30 minutes before you turn
it on. This is necessary because when the machine is horizontal, the oil from
the compressor flows into the refrigerant coils reducing the ability of the
dehumidifier to function.
|| Locate drainage system
E Termos The Evolution LGR pump connects to a plastic drainage hose. On the
| CORD DrizAir 1200 and 2000, you'll find the hose wrapped around the air outlet
located on the back of the unit. On the 2400, its just below the outlet (see
diagrams to left). Unwrap the entire hose (see caution below) and place the
unattached end in a sink, drain, bucket even outside; anywhere that water
can drain out safely. If you use a bucket or contained receptacle for water
collection, check it regularly.
CAUTION
5 == Ш | Uncoil and straighten the entire drain hose. Do not leave any of
| portion of the hose coiled om the unit. Also check for kinks, or
| | obstructions that would restrict the flow of water. Failure to do so
DrizAir 2400 may cause a water backup in the pump resulting in leakage.
CAUTION Plug in electrical cord
Dust can cause UNIt to overheat Locate the electrical cord either on the top or back of the unit. The entire
and shut down. line of DrizAir dehumidifiers runs on a 115-volt (15 amp) grounded outlet,
Do not operate unit when dust or air- which is standard in most homes. For the DrizÆir 1200, 2000 and 2400,
bome particles are present, such as dur- press the “on” button on the touchpad.
ing sanding or spray-painting. If the unit experiences a loss of power, which can result from a power inter-
Inspect and clean coils frequently ruption or overheating, we recommend you let the unit sit off for five minutes
Read and understand manual before restarting. Otherwise it might shut off again.
before use.
07-01480 А 04-04 Copyright 2004 Dri-Eaz Products, Inc.
READ AND SAVE THESE INSTRUCTIONS
How To UsE THE ToucHPAD CONTROL KEys
The Touchpad on DrizAir dehumidifiers has one display and four keys. The
normal display messages are:
DEHUMIDIFIER OFF CMPRSR DELAY
DEHUMIDIFIER ON PUMP PURGING
TOTAL HRS DEFROST ON
JOB HRS GET SERVICE ERO4
BPA En [UN DIE when you first plug in the unit, the touchpad display will cycle contin-
uously through three messages: DEHUMIDIFER OFF, TOTAL
HOURS, and JOB HOURS.
ON-OFF. Press the ON-OFF key to tum the unit on or off. When
Illustration of Touchpad tuming the machine on, usually the display reads CMPRSR
DELAY and performs a numeral count down from a maximum of
60 seconds to 0. The compressor delay gives the machine time to
warm up (when needed). If you dont see a compressor delay
countdown, the machine is ready to go. Once the unit completes
the CMPRSR DELAY, the display reads DEHUMIDIFIER ON, and
continues to cycle between TOTAL HOURS, JOB HOURS and
DEHUMIDIFIER ON.
Press the ON-OFF key again to tum the unit off. The display will
read DEHUMIDIFIER OFF
O DISPLAY. Press the DISPLAY key to stop the display at DEHUMID-
IFER ON or OFF, TOTAL HOURS, or JOB HOURS as it cycles.
Press DISPLAY again to re-start the display cycle.
How to change the language display
CAUTION
While in the change-language mode, pressing other keys can
change the programming of the machine. Do NOT press other
keys youre not instructed to press.
Use the DISPLAY key to change the display language.
Follow these steps:
1. Start with the unit unplugged.
2. While holding down the DISPLAY key, plug the unit in.
The display reads ENGLISH.
3. To change to FRANCAIS, DEUTSCH, or ESPANOL,
press the DISPLAY key or the CLEAR key.
4. When the desired language is shown in the display,
unplug the unit, and the language is set.
CLEAR. Press the CLEAR key to reset the JOB HOURS:
1. As the display cycles between DEHUMIDIFIER ON, JOB
HOURS, OR TOTAL HOURS, press the DISPLAY key
when JOB HOURS appears on the screen. That will
make the display read JOB HOURS steadily.
2. Then press the CLEAR key to re-set the numerals to
00000.
3. Press DISPLAY again to re-start the display cycle.
NOTE: the TOTAL HOURS reading cannot be re-set.
07-01488 A 04-04 Copyright 2004 Dri-Eaz Products, Inc.
READ AND SAVE THESE INSTRUCTIONS
PURGE. Press the PURGE key to empty water from the pump
reservoir. During normal operation, the pump purges automatically
A WARNING every six minutes, or whenever the reservoir is full. The display will
read PUMP PURGING with a numeral countdown.
To purge the pump manually:
lll 1) Tum the power off using the OFF key, and let the unit sit
wv plugged in for about 10 minutes. This allows water to drip
from the coils.
ELECTRIC SHOCK 2) Press PURGE to remove residual water.
HAZARD
Unplug unit before performing Other displays
During normal operation, the temperature sensor detects frost forming on the
Never use a water hose or pres- coils, causing a defrost cycle to start. The display will read DEFROST ON.
sure washer to clean coils; water
partment causing a shock cycle, the display returns to DEHUMIDIFIER ON.
hazard.
Error messages
Follow cleaning instructions in When the display menu shows the error message "GET SERVICE," followed
manual. by "ERO1" or another numeral, follow these steps:
1. Unplug the unit and then plug it back in. This may re-set the
electronics.
2. If that does not fix the problem, try the solution (if one is listed) in
the “Error Message Table” to the left.
J. If that does not fix the problem, contact the Dri-Eaz Service
Error Message Table Department at 868-867-3235.
FR Problem with electronic .
1235 control panel. Contact Dri- Mai nte nance
Eaz Service at 888-867-
6 3233. MAINTENANCE INTERVALS
ER 4 Check the temperature or
sensor cable, contact A WARNING °Ш
Service for instructions ELECTRIC SHOCK HAZARD
838-867-3235. Unplug any DrizAir dehumidifier before performing maintenance.
ER 8 Check the touchpad key.
Press and release each Before Each Use
key several times. - Inspect the electrical cord for damage. Look for fraying, cuts, etc. Do not
use the unit if you find any. Call Dri-Eaz for the nearest Service Center
888-867-3235.
ER 9 Check for obstructions or = Inspect filter. Look for accumulated dust and dirt that would restrict airflow
kinks in the drain hose. through the filter into the unit. If any is visible, vacuum out the debris. Do
not wash the filter, as it will reduce the effectiveness of the electrostatic
material.
IMPORTANT: Replace the filter whenever
» It has been vacuumed clean 3 times
* It has been used on a meld remediation job
Monthly
Remove housing, in order to locate the coils, catch basin, float shaft, and
drain hose.
07-01486 А 04-04 Copyright 2004 Dri-Eaz Products, Inc.
READ AND SAVE THESE INSTRUCTIONS
« Check coils, and clean when visibly dirty (see diagram 1). Dirty
coils can cause the unit to overheat.
1. Unplug unit
2. Remove housing, locate coils and allow coils to dry if wet.
3. Vacuum both sides of the coils until clean, being careful not to let the
nozzle touch the fins; as that may cause damage by bending them.
= Check catch basin tray. and clean when dirt and debris are present.
1. Wipe clean with a rag.
« Check drain hose.
1. Look for obstructions. Disconnect and clear any debris present.
2. Reattach gravity drain hose.
Annually
Have ihe pump system inspecied.
1. Call a the Dri-Eaz Service Department, and they'll help locate a
service center near you 888-867-3235.
2. To inspect the pump system yourself, use the detailed instructions
located at www. dri-eaz com in the Service section. Once there, click
“repairs” on the left menu and select Troubleshoot a leaking
pump. Be sure to follow the directions specific to the model you
own. If you have questions as you go through the process, call a Dri-
Eaz Service associate for assistance at 888-867-3233.
Diagram 1
lag Diagram 2
DrizAir 1200 DrizAir 2000/2400
mg
Re
+
LEE à
2)
EL
J
07-01-4806 À 04-04 Copyright 2004 Dri-Eaz Products, Inc.
TROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our Service Department toll free at 888-867-3235.
PROBLEM CAUSE SOLUTION
Unit does not operate No power to machine Plug in the unit; check power at outlet.
Switch not turned on Tum on switch.
Compressor will not start Unit needs 5 minutes before restart Switch off unit, wait 5 minutes before starting.
Overload preventing start up Reduce room temperature below 90°F (32°C).
Blower wheel not tuming Obstructed blower Remove obstruction.
Loose blower wheel set screw Tighten Screw.
Unit operating, but room not dry Not enough time to dry Allow more time for drying.
Poor air movement in room Increase aimovement with TurboDryers.
Excessive air infiltration Reduce airflow into the area being dried.
Unit continuously in defrost Room temperature too low Increase room temperature.
Unit collects little water Room air is dry Check humidity with hygrometer.
Room temperature too low Increase the room temperature.
Airflow through unit restricted Check filter and coils, clean if debris.
Pump does not function Stuck float valve Clean float valve shaft.
SPECIFICATIONS
MODEL DRIZAIR 1200, F203 CONTROLS TOUCHPAD
DrizAir TYPE STANDARD REFRIGERANT [HOUR METER YES
1200 HEIGHT 32" (83 CM) WATER PUMP-OUT — |CENTRIFUGAL
WIDTH 20" (50 CM) DRAIN HOSE LENGTH |40 FT (122 M}
" DEPTH 19.5" (50 СМ) AIR FILTER IM HIGH AIRFLOW®
USE WEIGHT 60 18 (36 КС) WHEELS SEMI-PNEUMATIC
WATER REMOVAL MAX [122 PT/DAY (58 L) HANDLE TELESCOPING
WATER REMOVAL AHAM [64 PT/DAY (30 Г.) HOUSING ROTOMOLDED
OPERATING RANGE 33°-100° F(1°-38°C) [POWER 115V 6.4 AMPS
COMPRESSOR TYPE 6,670 BTU ROTARY CORD LENGTH 25 FT (7.6 M)
DEFROST TYPE HOT-GAS BYPASS SAFETY MARKS UL, C-UL
PROCESS AIR 227 CFM (386 CMH)
DrizAir
2000 LOW GRAIN REFRIGERANT |HOUR METER YES
" (50 СМ) DRAIN HOSE LENGTH [40 FT (12.2 MI)
USE WEIGHT 137 LB (БО Кб) WHEELS SEMI-PNEUMATIC
TER REMOVAL MAX 4PTIDAY (106 L) HANDLE FIXED METAL
j
TING RANGE 33° 100° F(1°-38°C) — [POWER 115V 8 AMPS
PROCESS AIR 360 CFM (511 CMH)
DrizAir MODEL DRIZAIR 2400, F246 CONTROLS TOUCHPAD
2400 TYPE [OW GRAIN REFRIGERANT [HOUR METER YES
HEIGHT 47" (119 CM) WATER PUMP-OUT CENTRIFUGAL
WIDTH 24" (61 СМ) DRAIN HOSE LENGTH [40 FT (22M)
DEPTH 27" (63 CM) AIR FILTER 3M HIGH AIRFLOW*
USE WEIGHT 167 LB (73 KG) WHEELS SEMI-PNEUMATIC
WATER REMOVAL MAX — [220 PT/DAY (1141) HANDLE ROTOMOLD METAL
WATER REMOVAL AHAM |148 PT/DAY (701) HOUSING ROTOMOLDED
OPERATING RANGE 33° 100° F(1°-35°C) — [POWER 115V 11 AMPS
COMPRESSOR TYPE 13.315 BTU ROTARY CORD LENGTH 75 FT (7.6 M)
DEFROST TYPE HOT-GAS BYPASS SAFETY MARKS UL, C-UL
PROCESS AIR 360 CFM (517 CMA)
07-01480 А 04-04 Copyright 2004 Dri-Eaz Products, Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement