GE DPSB619EDWW Profile™ 7.0 Cu. Ft. Super Capacity Electric Dryer Quick Specs
Advertisement
Advertisement
25-1/2
27
42
51
36
Side View Rear View
5.7 cu. ft. Dryers
2''
30-1/2''
Power
Cord Hole
Back View dpsb619edww – Ge profile ™ super 7.0 Cu. Ft. Capacity electric dryer with stainless steel drum
23-1/2 28-1/4
25-1/2*
8-1/2
Side View
*24-1/2" from the edge of the side panel to the front.
25-1/2" from front to edge of endcaps.
36
42
2-1/2
11-1/2
2
27
3-1/2
Rear View exhaust Options:
4-way via rear, right, left and bottom.
NeMA Receptacle codes:
3-prong dryer cord/30A/4' long (cat #WX9X2) is for NEMA10-30R receptacle
4-prong dryer cord/30A/4' long (cat #WX9X18) is for NEMA14-30R receptacle
Circuit Requirements:
An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
electric dryer Rating:
240V, 5600W, 24A, 60Hz
208V, 4400W, 22A, 60Hz
Note:
Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.
Installation Information:
For complete information, see installation instructions packed with your dryer.
5''
Washer/Dryers SC QSart
Power
Cord Hole
4-1/2''
Back View specification Revised 4/06
270186
Listed by
Underwriters
Laboratories
For answers to your Monogram, ® GE Profile ™ or
GE ® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center ® service, 800.626.2000.
GE Dryer Vent
GE Dryer Vent dpsb619edww – Ge profile ™ super 7.0 Cu. Ft. Capacity electric dryer with stainless steel drum dryer exhausting Information – Use Metal duct Only
Vertical and Horizontal ducting
A
A
A
4
4 B
B
Domestic
Dryer Models
2-1/2
2-1/2
7.3 Capacity Electric and Gas Dryers
7.0 and 6.0
Capacity Models all Electric Dryers
7.0 and 6.0
Capacity Models all Gas Dryers
5.7 Capacity Electric and Gas Dryers
Number of
90°
Turns
0
1
2
3
4
0
1
2
3
0
1
2
3
4
0
1
2
3
4
Best Performance
Maximum Length of 4"
Dia. Rigid Metal Duct
Exhaust Hood Type
A
4" Opening
90 ft.
60 ft.
45 ft.
35 ft.
60 ft.
52 ft.
44 ft.
32 ft.
28 ft.
150 ft.
140 ft.
130 ft.
120 ft.
110 ft.
90 ft.
60 ft.
45 ft.
35 ft.
25 ft.
B
2-1/2"
Opening
60 ft.
45 ft.
35 ft.
25 ft.
48 ft.
40 ft.
32 ft.
24 ft.
16 ft.
127 ft.
117 ft.
107 ft.
97 ft.
87 ft.
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
Maximum Length of 4"
Dia. Flexible Metal Duct
Exhaust Hood Type
A
4" Opening
55 ft.
40 ft.
30 ft.
20 ft.
30 ft.
22 ft.
14 ft.
—
—
75 ft.
65 ft.
55 ft.
45 ft.
35 ft.
55 ft.
40 ft.
30 ft.
20 ft.
15 ft.
B
2-1/2"
Opening
45 ft.
30 ft.
20 ft.
15 ft.
18 ft.
14 ft.
10 ft.
—
—
52 ft.
42 ft.
32 ft.
22 ft.
12 ft.
45 ft.
30 ft.
20 ft.
15 ft.
10 ft.
special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
bathroom or bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" both sides
3" rear specification Revised 4/06
270186
For complete information, see installation instructions packed with your dryer.
ducting Materials:
For best performance, this dryer should be vented with 4" diameter all-rigid metal exhaust duct. If
“all-rigid metal” duct cannot be used, then “flexible all-metal” venting can be used, but it will reduce the maximum recommended duct length.
exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown
in the table. The maximum length for flexible ducts are less than for rigid duct.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a
90° elbow. A turn over 45° should be treated as a 90° elbow.
exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc.
The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a
4" opening dampered wall cap.
For more information on venting kits and accessories, please call 1-800-Ge-CARes.
Listed by
Underwriters
Laboratories
For answers to your Monogram, ® GE Profile ™ or
GE ® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center ® service, 800.626.2000.
dpsb619edww – Ge profile ™ super 7.0 Cu. Ft. Capacity electric dryer with stainless steel drum
COTTONs
MIXed
LOAds
Sensor Dry Cycle eAsY CARe
PERM PRESS
KNITs sweATeRs deLICATes s de wRINKLe wARM
Up
DRYNESS dRY
HEAT LEVEL
HIGH
MedIUM
LOw dAMp
SPEED
DRY
CUsTOM
Sensor Dry Plus
1
CUsTOM
2
TIMED DRY eXTeNd
TUMbLe
OPTIONS sIGNAL dAMp sIGNAL deLAY
1-8 hrs.
TIMED DRY
30 MIN
MORe
Less
EXTENDED TUMBLE
CLEAN LINT FILTER
START
PAUSE
STOP
EST. TIME REMAININ
SENSING
G
Features and benefits
• Sensor Dry Plus – Continually monitors moisture levels to help clothes look better than ever, longer than ever
• Full Electronic Controls with Adaptive Logic System ™ and LED Readout – Simplify cycle selections and provide accurate cycle times
• Speed Dry – Delivers ready-to-go results in minutes
• Five Heat Selections – Temperatures are matched to fabric type for better fabric care
• Interior Dryer Light – Lets you see everything inside for easy loading and unloading
• Multiple Dry Cycles, Including Custom Options – Cycles are matched to fabric type for enhanced drying performance and flexibility
• Luxury Quiet Performance – Minimizes operating noise
• Variable End-of-Cycle Signal – Adjustable volume offers added flexibility
• Delay Start – Lets you do the laundry on your items
• Deluxe Dryer Rack – Allows tumble-free drying of items like sneakers and stuffed animals
• Model DPSB619EDWW – White on white specification Revised 4/06 DPSB619ED/GD
270186

Download
Advertisement