Siemens 4700 Power Meter Operator’s Manual

The 4700 Power Meter is a microprocessor-based instrumentation package for low, medium or high voltage electrical equipment and substations. It is a state-of-the-art alternative to traditional analog electromechanical metering devices. The unit is economical and is easy to install and operate. It requires no external transducers. The unit can be configured to operate in wye (star), delta, or single-phase voltage modes. The following measurements are available: Current on each phase, A fourth current input (I4), Line-to-line voltages, Frequency, Power factor, kVA, kW, kVAR, kW Demand, VAUX (auxiliary voltage input), Total MWHr, Total MVARHr.

PDF Download
Document
Siemens 4700 Power Meter Operator’s Manual | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • Microprocessor-based
  • Easy to install
  • No external transducers
  • Wye, delta, single-phase
  • Data logging
  • Control capability
  • Communications capability

Frequently asked questions

The 4700 Power Meter provides measurements for current on each phase, a fourth current input (I4), line-to-line voltages, frequency, power factor, kVA, kW, kVAR, kW Demand, VAUX (auxiliary voltage input), Total MWHr, and Total MVARHr.

Yes, the 4700 Power Meter can be configured to operate in wye (star), delta, or single-phase voltage modes.

The 4700 Power Meter should be located in a dry, dirt-free environment, away from heat sources and very high electric fields.

The chassis of the 4700 Power Meter must be connected to earth ground. A good, low-impedance chassis ground is essential for the 4700 Power Meter surge and transient protection circuitry to function effectively.

The 4700 Power Meter can record up to three data logs: EVENT Log, SNAPSHOT Log, and MIN/MAX Log.

User questions

H Y

H Y

How to connect a 4700 Power Meter to different power systems (single-phase, three-phase wye, three-phase delta)?
Specific system configuration details are required to provide connection instructions for the 4700 Power Meter.
H Y

H Y

How to connect voltage transformers, current transformers, status inputs, and control relays to a 4700 Power Meter?
Detailed component specifications are needed to provide connection instructions for the 4700 Power Meter.
H Y

H Y

What are the proper wiring practices and safety precautions for installing a 4700 Power Meter (grounding, wire gauge, terminal block connections)?
Detailed information on grounding, wire gauge selection, and appropriate terminal block connections for the 4700 Power Meter is required.