Split Air Conditioner
6SOLW$LU&RQGLWLRQHU
2:1(5
6 0$18$/
LENNOX $ , 5 & 2 1 ' , 7 , 2 1 ( 5 6
02'(/
LI012CI-160P432
LI012CO-160P432
LI018CI-160P432
LI018CO-160P432
LI024CI-160P432
LI024CO-160P432
LI012HI-160P432
LI012HO-160P432
LI018HI-160P432
LI018HO-160P432
LI024HI-160P432
LI024HO-160P432
7KDQN\RXIRUVHOHFWLQJLENNOXDLUFRQGLWLRQHUV3OHDVHUHDGWKLVPDQXDO
FDUHIXOO\EHIRUHRSHUDWLRQDQGNHHSLWIRUIXUWKHUUHIHUHQFH
Content
Operation Notices
Precautions............................................................................................................1
Parts Name............................................................................................................6
ScreenOperation Guide
Buttons on remote controller .................................................................................8
Introduction for icons on display screen ............................................................... 8
Introduction for buttons on remote controller .........................................................9
Function introduction for combination buttons .....................................................13
Operation guide ...................................................................................................14
Replacement of batteries in remote controller .....................................................14
Emergency operation .......................................................................................... 15
Maintenance
Clean and Maintenance....................................................................................... 15
Malfunction
Malfunction analysis ............................................................................................18
Installation Notice
Installation dimension diagram ............................................................................22
Tools for installation .............................................................................................23
Selection of installation location ..........................................................................23
Requirements for electric connection ..................................................................24
Installation
Installation of indoor unit......................................................................................25
Installation of outdoor unit ...................................................................................30
Vacuum pumping .................................................................................................33
Leakage detection ...............................................................................................33
Check after installation ........................................................................................34
Test and operation
Test operation ......................................................................................................34
Attachment
Configuration of connection pipe .........................................................................35
Pipe expanding method .......................................................................................37
Wired Controller................................................................................................... 38
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Explanation of Symbols
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock.
.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
1
Precautions
WARNING
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
Ɣ Power cord is overheating or damaged.
Ɣ There’s abnormal sound during operation.
Ɣ Circuit break trips off frequently.
Ɣ Air conditioner gives off burning smell.
Ɣ Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
2
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table.Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
3
Precautions
WARNING
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
4
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(ć )
26.7/19.4(80/66.9)
26.7/-(80/-)
Outdoor side DB/WB(ć )
46.1/23.9(115/75)
23.9/18.3(75/64.9)
NOTICE:
Ɣ The operating temperature range (outdoor temperature) for cooling only unit is
-18ć(-0.4°F)~46.1℃(115°F);for heat pump unit is-20℃(-4°F)~46.1℃(115°F).
5
Parts Name
Indoor Unit
air inlet
panel
aux.button
horizontal louver
air outlet
F
C
HOUR
ONOFF
2 1 /2 ) )
02'(
)$1
6:,1* ,)((/
6/((3
7(03
7,0(521
&/2&.
7,0(52))
785%2 /,*+7 ;)$1
remote control
(Display content or position may be different from above
graphics, please refer to actual products)
Outdoor Unit
air inlet
Connection wire
air outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
6
Parts Name
Display
For some model:
cooling
indicator
For some model:
power
indicator
receiver
window
temp.
indicator
heating
indicator
display
cooling
indicator
heating
indicator
temp.
indicator
drying
display
indicator
receiver
window
power
indicator
drying
indicator
For some model:
display
temp.
indicator
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
receiver
window
Mode LED color indicator:
W
R
G
White-W-Cool ModeRed-R-Heat Mode-
W
(only for heating model)
R
Green-G-Dry Mode- G
For some model:
display
temp.
indicator
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
receiver
window
Mode LED color indicator:
W
R
O
White-W-Cool ModeRed-R-Heat Mode-
R
W
(only for heating model)
Orange-O-Dry Mode- O
Display content or position may be different from above graphics, please refer to actual
products.
7
Buttons on remote controller
F
C
1
2 1 /2 ) )
2
HOUR
ONOFF
3
1
ON/OFF button
2
- button
3
+ button
4
MODE button
5
FAN button
6
SWING button
7
I FEEL button
8
4
02'(
6
6:,1* ,)((/
)$1
/
button
5
9
7
10 TEMP button
SLEEP button
8
6/((3
9
11 TIMER-ON button
10
7(03
7,0(521
11
12 CLOCK button
12
&/2&.
7,0(52))
13
13 TIMER-OFF button
14
785%2 /,*+7 ;)$1
16
14 TURBO button
15
15 LIGHT button
16 X-FAN button
Introduction for icons on display screen
X-fan
set fan speed
send signal
turbo mode
ventilation operation
health mode
I feel
8ć heating function
Operation mode
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
set temperature
set time
TIMER ON/TIMER OFF
Clock
Sleep mode
light
Child lock
Up & down swing
Temp. display type
:Set temp.
:Indoor ambient temp.
:Outdoor ambient temp.
8
Introduction for buttons on remote controller
Note:
Ɣ$IWHUSXWWLQJWKURXJKSRZHUDLUFRQGLWLRQHUZLOOJLYHRXWDVRXQGDQGRSHUDWLRQ
indicator " " is ON (red indicator). You can operate the air conditioner through
the remote controller.
Ɣ$W21VWDWXVDIWHUHDFKSUHVVLQJEXWWRQRQUHPRWHFRQWUROOHUWKHVLJQDOLFRQ
RQUHPRWHFRQWUROOHUZLOOÀDVKRQFH$LUFRQGLWLRQHUZLOOJLYHRXWDVRXQGZKLFK
indicates the signal has been sent to air conditioner.
1
ON/OFF button
Press this button to turn on the unit. Press this button again to turn off the unit.
2
- button
Press this button to decrease set temperature. Holding it down above 2 seconds
UDSLGO\GHFUHDVHVVHWWHPSHUDWXUH,Q$872PRGHVHWWHPSHUDWXUHLVQRW
adjustable.
3
+ button
Press this button to increase set temperature. Holding it down above 2 seconds
UDSLGO\LQFUHDVHVVHWWHPSHUDWXUH,Q$872PRGHVHWWHPSHUDWXUHLVQRW
adjustable.
4
MODE button
(DFKWLPH\RXSUHVVWKLVEXWWRQDPRGHLVVHOHFWHGLQDVHTXHQFHWKDWJRHVIURP
$872&22/'5<)$1DQG+($7DVWKHIROORZLQJ
AUTO
COOL
DRY
FAN
+($7
1RWH2QO\IRUPRGHOVZLWKKHDWLQJIXQFWLRQ
$IWHUHQHUJL]DWLRQ$872PRGHLVGHIDXOWHG,Q$872PRGHWKHVHWWHPSHUDWXUH
ZLOOQRWEHGLVSOD\HGRQWKH/&'DQGWKHXQLWZLOODXWRPDWLFDOO\VHOHFWWKHVXLWDEOH
operation mode in accordance with the room temperature to make indoor room
FRPIRUWDEOH$VIRUFRROLQJRQO\XQLWLWZRQ¶WKDYHDQ\DFWLRQZKHQLWUHFHLYHVWKH
signal of heating operation.)
9
Introduction for buttons on remote controller
5 FAN button
7KLVEXWWRQLVXVHGIRUVHWWLQJ)DQ6SHHGLQWKHVHTXHQFHWKDWJRHVIURP$872
WRWKHQEDFNWR$XWR
Auto
Low speed
6
Medium speed
High speed
SWING button
3UHVVWKLVEXWWRQWRVHWXSGRZQVZLQJDQJOHZKLFKFLUFXODUO\FKDQJHVDVEHORZ
OFF
7KLVUHPRWHFRQWUROOHULVXQLYHUVDO,IDQ\FRPPDQGRULVVHQWRXWWKHXQLW
will carry out the command as
indicates the guide louver swings as:
7
I FEEL button
Press this button to turn on I FEEL function. The unit automatically adjust temperature according to the sensed temperature. Press this button again to cancel I FEEL
function.
8
/
button
Press this button to achieve the on and off of healthy and scavenging functions in
RSHUDWLRQVWDWXV3UHVVWKLVEXWWRQIRUWKH¿UVWWLPHWRVWDUWVFDYHQJLQJIXQFWLRQ
LCD displays " ". Press the button for the second time to start healthy and
VFDYHQJLQJIXQFWLRQVVLPXOWDQHRXVO\/&'GLVSOD\VDQG3UHVVWKLV
EXWWRQIRUWKHWKLUGWLPHWRTXLWKHDOWK\DQGVFDYHQJLQJIXQFWLRQVVLPXOWDQHRXVO\
3UHVVWKHEXWWRQIRUWKHIRXUWKWLPHWRVWDUWKHDOWK\IXQFWLRQ/&'GLVSOD\
Press this button again to repeat the operation above. (This function is applicable
to partial of models)
9
SLEEP button
Press this button to go into the SLEEP operation mode. Press it again to cancel
WKLVIXQFWLRQ7KLVIXQFWLRQLVDYDLODEOHLQ&22/+($72QO\IRUPRGHOVZLWK
heating function) mode to maintain the most comfortable temperature for you.
10
Introduction for buttons on remote controller
10 TEMP button
3UHVVWKLVEXWWRQFDQVHHLQGRRUVHWWHPSHUDWXUHLQGRRUDPELHQWWHPSHUDWXUHRU
RXWGRRUDPELHQWWHPSHUDWXUHRQLQGRRUXQLW¶VGLVSOD\7HPSHUDWXUHLVVHWFLUFXODUO\
by remote controller as below:
no display
Ɣ:KHQVHOHFWLQJE\UHPRWHFRQWUROOHURUQRGLVSOD\WHPSHUDWXUHLQGLFDWRURQ
indoor unit displays set temperature.
Ɣ:KHQVHOHFWLQJE\UHPRWHFRQWUROOHUWHPSHUDWXUHLQGLFDWRURQLQGRRUXQLW
displays indoor ambient temperature.
Ɣ:KHQVHOHFWLQJE\UHPRWHFRQWUROOHUWHPSHUDWXUHLQGLFDWRURQLQGRRUXQLW
displays outdoor ambient temperature.
Note:
Ɣ2XWGRRUDPELHQWWHPSHUDWXUHGLVSOD\PD\FDQ¶WEHVHOHFWHGIRUVRPHPRGHOV
:KHQLQGRRUXQLWUHFHLYHVVLJQDOLWGLVSOD\VLQGRRUVHWWHPSHUDWXUH
Ɣ2QO\IRUWKHPRGHOZKRVHLQGRRUXQLWKDVGXDOGLVSOD\
11
TIMER-ON button
3UHVVWKLVEXWWRQWRLQLWLDWHWKHDXWR21WLPHU7RFDQFHOWKHDXWRWLPHUSURJUDP
simply press this button again.
$IWHUSUHVVRIWKLVEXWWRQGLVDSSHDUVDQG21EOLQNVLVGLVSOD\HGIRU
21WLPHVHWWLQJ:LWKLQVHFRQGVSUHVVRUEXWWRQWRDGMXVWWKHWLPHYDOXH
Every press of either button changes the time setting by 1 minute. Holding down
either button rapidly changes the time setting by 1 minute and then 10 minutes.
:LWKLQ6HFRQGVDIWHUVHWWLQJSUHVV7,0(521EXWWRQWRFRQ¿UP
12
CLOCK button
3UHVV&/2&.EXWWRQEOLQNLQJ:LWKLQVHFRQGVSUHVVLQJRUEXWWRQDGMXVWV
the present time. Holding down either button above 2 seconds increases or
decreases the time by 1 minute every 0.5 second and then by 10 minutes every
VHFRQG'XULQJEOLQNLQJDIWHUVHWWLQJSUHVV&/2&.EXWWRQDJDLQWRFRQ¿UPWKH
VHWWLQJDQGWKHQZLOOEHFRQVWDQWO\GLVSOD\HG
13 TIMER-OFF button
3UHVVWKLVEXWWRQWRLQLWLDWHWKHDXWRRIIWLPHU7RFDQFHOWKHDXWRWLPHUSURJUDP
simply press the button again. TIMER OFF setting is the same as TIMER ON.
11
Introduction for buttons on remote controller
14 TURBO button
Press this button to activate / deactivate the Turbo function which enables the
XQLWWRUHDFKWKHSUHVHWWHPSHUDWXUHLQWKHVKRUWHVWWLPH,Q&22/PRGHWKHXQLW
ZLOOEORZVWURQJFRROLQJDLUDWVXSHUKLJKIDQVSHHG,Q+($7PRGHWKHXQLWZLOO
blow strong heating air at super high fan speed.
15
LIGHT button
Press LIGHT button to turn on the display's light and press this button again to turn
RIIWKHGLVSOD\
VOLJKW,IWKHOLJKWLVWXUQHGRQLVGLVSOD\HG,IWKHOLJKWLVWXUQHG
RIIGLVDSSHDUV
16
X-FAN button
3UHVVLQJ;)$1EXWWRQLQ&22/RU'5<PRGHWKHLFRQLVGLVSOD\HGDQGWKH
indoor fan will continue operation for 2 minutes in order to dry the indoor unit even
though you have turned off the unit.
$IWHUHQHUJL]DWLRQ;)$12))LVGHIDXOWHG;)$1LVQRWDYDLODEOHLQ$872)$1
or HEAT mode.
Function introduction for combination buttons
Combination of "+" and "-" buttons: About lock
Press "+" and "-" buttons simultaneously to lock or unlock the keypad. If the remote
FRQWUROOHULVORFNHGLVGLVSOD\HG,QWKLVFDVHSUHVVLQJDQ\EXWWRQEOLQNV
three times.
Combination of "MODE" and "-" buttons:
About switch between Fahrenheit and centigrade
$WXQLW2))SUHVV02'(DQGEXWWRQVVLPXOWDQHRXVO\WRVZLWFKEHWZHHQƒ&
DQGƒ)
12
Function introduction for combination buttons
Combination of "TEMP" and "CLOCK" buttons:
About Energy-saving Function
Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving
function. Nixie tube on the remote controller displays "SE". Repeat the operation to
TXLWWKHIXQFWLRQ
Combination of "TEMP" and "CLOCK" buttons:
About 8°C Heating Function
3UHVV7(03DQG&/2&.VLPXOWDQHRXVO\LQ+($7PRGHWRVWDUWƒ&+HDWLQJ
Function Nixie tube on the remote controller displays " " and a selected
WHPSHUDWXUHRIƒ&ƒ)LI)DKUHQKHLWLVDGRSWHG5HSHDWWKHRSHUDWLRQWRTXLW
the function.
About Back-lighting Function
7KHXQLWOLJKWVIRUVZKHQHQHUJL]LQJIRUWKH¿UVWWLPHDQGVIRUODWHUSUHVV
ƾ About HEALTH function (COLD PLASMA)
7XUQRQWKHXQLWVWDUWXSWKHIDQ%UHH]LQJDQG;)$1DUHH[FOXGHGDQGSUHVV
HEATLTH button on remote controller to start health function (If there is not
+($/7+EXWWRQRQUHPRWHFRQWUROOHUWKHXQLWGHIDXOWVKHDOWKIXQFWLRQ21
13
Operation guide
1.$IWHUSXWWLQJWKURXJKWKHSRZHUSUHVV212))EXWWRQRQUHPRWHFRQWUROOHUWR
turn on the air conditioner.
2.3UHVV02'(EXWWRQWRVHOHFW\RXUUHTXLUHGPRGH$872&22/'5<)$1
HEAT.
3.3UHVVRUEXWWRQWRVHW\RXUUHTXLUHGWHPSHUDWXUH7HPSHUDWXUHFDQ¶WEH
adjusted under auto mode).
4.3UHVV)$1EXWWRQWRVHW\RXUUHTXLUHGIDQVSHHGDXWRORZPHGLXPDQGKLJK
speed.
5. Press "SWING" button to select fan blowing angle.
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
ZLWKDVVKRZQLQWKH¿JDQGWKHQSXVKRXW
the cover of battery box along the arrow direction.
5HSODFHWZR$$$9GU\EDWWHULHVDQG
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
battery
reinstall
remove
Cover of battery box
Note:
Ɣ'XULQJRSHUDWLRQSRLQWWKHUHPRWHFRQWUROVLJQDOVHQGHUDWWKHUHFHLYLQJ
window on indoor unit.
Ɣ7KHGLVWDQFHEHWZHHQVLJQDOVHQGHUDQGUHFHLYLQJZLQGRZVKRXOGEHQR
PRUHWKDQPDQGWKHUHVKRXOGEHQRREVWDFOHVEHWZHHQWKHP
Ɣ6LJQDOPD\EHLQWHUIHUHGHDVLO\LQWKHURRPZKHUHWKHUHLVÀXRUHVFHQWODPS
RUZLUHOHVVWHOHSKRQHUHPRWHFRQWUROOHUVKRXOGEHFORVHWRLQGRRUXQLWGXULQJ
operation.
Ɣ5HSODFHQHZEDWWHULHVRIWKHVDPHPRGHOZKHQUHSODFHPHQWLVUHTXLUHG
Ɣ:KHQ\RXGRQ¶WXVHUHPRWHFRQWUROOHUIRUDORQJWLPHSOHDVHWDNHRXWWKH
batteries.
Ɣ,IWKHGLVSOD\RQUHPRWHFRQWUROOHULVIX]]\RUWKHUH¶VQRGLVSOD\SOHDVH
replace batteries.
14
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
WARNING:
Use insulated object to press the auto button
Clean and Maintenance
WARNING
Ŷ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
Ŷ'RQRWZDVKWKHDLUFRQGLWLRQHUZLWKZDWHUWRDYRLGHOHFWULFVKRFN
Ŷ'RQRWXVHYRODWLOHOLTXLGWRFOHDQWKHDLUFRQGLWLRQHr.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
NOTICE:
Ɣ'RQRWUHPRYHWKHSDQHOZKHQFOHDQLQJLW
15
Clean and Maintenance
1
Open panel
3
Pull out the panel to a certain
Ɣ8VHGXVWFDWFKHURUZDWHUWR
WKHZDWHUEHORZć ) to clean
LWDQGWKHQSXWLWLQDVKDG\
DQGFRROSODFHWRGU\.
2
4
panel cover tightl\.
WARNING
RSHUDWLRQHQYLURQPHQWFOHDQIUHTXHQF\FDQEHLQFUHDVHG
16
Clean and Maintenance
NOTICE: Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether air switch, plug and socket are in good condition.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
NOTICE: Checking after use-season
1. Disconnect power supply.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
17
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
FDQ¶WEHHOLPLQDWHGSOHDVHFRQWDFWORFDOGHDOHURUTXDOL¿HGSURIHVVLRQDOV
Phenomenon
Check items
Solution
Ɣ:KHWKHULW
VLQWHUIHUHGVHYHUHO\ Ɣ3XOORXWWKHSOXJ5HLQVHUW
(such as static electricity,stable the plug after about 3min, and
voltage)?
then turn on the unit again.
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
Ɣ:KHWKHUUHPRWHFRQWUROOHULV
within the signal receiving
range?
Ɣ6LJQDOUHFHLYLQJUDQJHLVP
Ɣ:KHWKHUWKHUHDUHREVWDFOHV"
Ɣ5HPRYHREVWDFOHV
Ɣ:KHWKHUUHPRWHFRQWUROOHULV
ƔSelect proper angle and point
pointing at the receiving
the remote controller at the rewindow?
ceiving window on indoor unit.
Ɣ,VVHQVLWLYLW\RIUHPRWHFRQWUR Ɣ&KHFNWKHEDWWHULHV,IWKH
power of batteries is too low,
OOHUORZIX]]\GLVSOD\DQGQR
please replace them.
display?
Ɣ&KHFNZKHWKHUUHPRWHFRQW
Ɣ1RGLVSOD\ZKHQRSHUDWLQJ
roller appears to be damaged.
remote controller?
If yes, replace it.
Ɣ)OXRUHVFHQWODPSLQURRP"
No air
emitted
from
indoor
unit
Ɣ7DNHWKHUHPRWHFRQWUROOHU
close to indoor unit.
Ɣ7XUQRIIWKHÀXRUHVHQWODPS
and then try it again.
Ɣ$LULQOHWRUDLURXWOHWRILQGRRU
unit is blocked?
Ɣ(OLPLQDWHREVWDFOHV
Ɣ8QGHUKHDWLQJPRGHLQGRRU
temperature is reached to set
temperature?
Ɣ$IWHUUHDFKLQJWRVHWWHPSHU
ature, indoor unit will stop blowing out air.
Ɣ+HDWLQJPRGHLVWXUQHGRQMXVW Ɣ,QRUGHUWRSUHYHQWEORZLQJ
now?
out cold air, indoor unit will be
started after delaying for several minutes, which is a normal phenomenon.
18
Malfunction analysis
Phenomenon
Air conditioner can’t
operate
Mist is emitted from
indoor unit’s
air outlet
Set temperature can’t
be adjusted
Cooling
(heating)
effect is
not good.
Check items
Solution
Ɣ3RZHUIDLOXUH"
Ɣ:DLWXQWLOSRZHUUHFRYHU\
Ɣ,VSOXJORRVH"
Ɣ5HLQVHUWWKHSOXJ
Ɣ$LUVZLWFKWULSVRIIRUIXVHLV
burnt out?
Ɣ$VNSURIHVVLRQDOWRUHSODFH
air switch or fuse.
Ɣ:LULQJKDVPDOIXQFWLRQ"
Ɣ$VNSURIHVVLRQDOWRUHSODFHLW
Ɣ8QLWKDVUHVWDUWHGLPPHGLDWHO\
Ɣ:DLWIRUPLQDQGWKHQWXUQ
after stopping operation?
on the unit again.
Ɣ:KHWKHUWKHIXQFWLRQVHWWLQJ
for remote controller is
correct?
Ɣ5HVHWWKHIXQFWLRQ
Ɣ,QGRRUWHPSHUDWXUHDQGKXP
idity is high?
Ɣ%HFDXVHLQGRRUDLULVFRROHG
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
Ɣ8QLWLVRSHUDWLQJXQGHUDXWR
mode?
Ɣ7HPSHUDWXUHFDQ¶WEHDGMX
sted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
Ɣ<RXUUHTXLUHGWHPSHUDWXUH
exceeds the set temperature
range?
Ɣ6HWWHPSHUDWXUHUDQJH
16ć ~30ć .
Ɣ9ROWDJHLVWRRORZ"
Ɣ:DLWXQWLOWKHYROWDJH
resumes normal.
Ɣ)LOWHULVGLUW\"
Ɣ&OHDQWKH¿OWHU
Ɣ6HWWHPSHUDWXUHLVLQSURSHU
range?
Ɣ$GMXVWWHPSHUDWXUHWRSURSHU
range.
Ɣ'RRUDQGZLQGRZDUHRSHQ"
Ɣ&ORVHGRRUDQGZLQGRZ
19
Malfunction analysis
Phenomenon
Odours are
emitted
Check items
Solution
Ɣ:KHWKHUWKHUH¶VRGRXUVRXUFH Ɣ(OLPLQDWHWKHRGRXUVRXUFH
such as furniture and cigarette,
Ɣ&OHDQWKH¿OWHU
etc.
Ɣ:KHWKHUWKHUH¶VLQWHUIHUHQFH
such as thunder, wireless
devices, etc.
Ɣ'LVFRQQHFWSRZHUSXWEDFN
power, and then turn on the
unit again.
Outdoor
unit has
vapor
Ɣ+HDWLQJPRGHLVWXUQHGRQ"
Ɣ'XULQJGHIURVWLQJXQGHUKH
ating mode, it may generate
vapor, which is a normal
phenomenon.
“Water
ÀRZLQJ´
noise
Ɣ$LUFRQGLWLRQHULVWXUQHGRQRU
turned off just now?
Ɣ7KHQRLVHLVWKHVRXQGRI
UHIULJHUDQWÀRZLQJLQVLGH
the unit, which is a normal
phenomenon.
Air conditioner operates
abnormally
Cracking
noise
Ɣ$LUFRQGLWLRQHULVWXUQHGRQRU
turned off just now?
20
Ɣ7KLVLVWKHVRXQGRIIULFWLRQ
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
Malfunction analysis
Error Code
Ɣ:KHQDLUFRQGLWLRQHUVWDWXVLVDEQRUPDlWHPSHUDWXUHLQGLFDWRURQLQGRRUXQLWZLOO
DWLRQRIHUURUFRGH
(UURUFRGH
E5
E8
U8
H6
TURXEOHVKRRWLQJ
,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRWSOHDVH
,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRW,SOHDVH
,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRW,SOHDVH
,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRW,SOHDVH
C5
F1
F2
1RWH,IWKHUH
UHRWKHUHUURUFRGHVSOHDVHFRQWDFWTXDOLILHGSURIHVVLRQDOVIRUVHUYLFH
WARNING
Ŷ:KHQEHORZSKHQRPHQRQRFFXUVSlHDVHWXUQRIIDLUFRQGLWLRQHUDQGGLVFRQ
IRUVHUYLFH
Ɣ3RZHUFRUGLVRYHUKHDWLQJRUGDPDJHG
Ɣ7KHUH’VDEQRUPDOVRXQGGXULQJRSHUDWLRQ
Ɣ$LUVZLWFKWULSVRIIIUHTXHQWOy
Ɣ$LUFRQGLWLRQHUJLYHVRIIEXUQLQJVPHOO
Ɣ,QGRRUXQLWLVOHDNLQJ
Ŷ,IWKHDLUFRQGLWLRQHURSHUDWHVXQGHUDEQRUPDOFRQGLWLRQVLWPD\FDXVH
1
At least 15cm
Space to the ceiling
Installation dimension diagram
Space to the wall
At least 15cm
At least 15cm
e
ac
to
lea
the
on
cti
tru
s
ob
the
to n
e
ac ctio
Sp stru
st
ob
lea
t
A cm
30
At least 50cm
Space to the obstruction
Sp
At least 250cm
cm
00
3
st
At
6SDFHWRWKHÀRRU
Space to the wall
At least 30cm
Space to th
e wall
At least 50cm
n
tio
c
tru
s
ce
a
Sp
t
he
ot
ob
st
a
t le
m
0c
Space to the
obstruction
20
A
Drainage pipe
2
Tools for installation
1 Level meter
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
Note:
14 Measuring tape
Ɣ3OHDVHFRQWDFWWKHORFDODJHQWIRULQVWDOODWLRQ
Ɣ'RQ
WXVHXQTXDOL¿HGSRZHUFRUG
Selection of installation location
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local
dealer:
1.The place with strong heat sources,
,
or volatile objects spread in the air.
2.The place with high-frequency
devices (such as welding machine,
medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.The appliance shall not be installed in the laundry.
Outdoor unit
Indoor unit
1. There should be no obstruction near air
inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to
connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5. The location should be able to withstand
the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep way from
fluorescent lamp.
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
ZRQ
WEHH[SRVHGGLUHFWO\WRVXQOLJKWRUVWURQJZLQG
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
3
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
4
Installation of indoor unit
Step one: choosing installation location
rm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
09 K:
Wall
12K:
Mark in the middle of it
Space
to the
wall
above
150mm
Wall
Wall
Level meter
Left
ĭPP
Rear piping hole
Wall
Level meter
Space
to the
wall
above
150mm
Left
ĭPP
Rear piping hole
Right
ĭPP
Rear piping hole
18K:
Wall
Mark in the middle of it
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Right
ĭPP
Rear piping hole
24K:
Mark in the middle of it
Space
to the
wall
above
150mm
Left
ĭ
Rear piping hole
Level meter
Wall
Wall
Mark in the middle of it
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Right
ĭ
Rear piping hole
Left
ĭPP
Rear piping hole
Level meter
Wall
Space
to the
wall
above
150mm
Right
ĭPP
Rear piping hole
2SHQDSLSLQJKROHZLWKWKHGLDPHWHURIĭRUĭRQWKHVHOHFWHGRXWOHWSLSH
position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
5
Installation of indoor unit
Indoor
outdoor
Note:
Ɣ3D\DWWHQWLRQWRGXVWSUHYHQWLRQDQG
WDNHUHOHYDQWVDIHW\PHDVXUHVZKHQ
opening the hole.
Ɣ The plastic expansion particles are
QRWSURYLGHGDQGVKRXOGEHERXJKW
locally.
ĭ
ĭ
5-10
Step four: outlet pipe
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
left
right
left
rear right
rear left
right
cut off
the hole
1. Aim the pipe joint at the corresponding
bellmouth.
pipe joint
union nut
pipe
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
6
Installation of indoor unit
open-end
wrench
union nut
torque wrench
pipe
Hex nut diameter Tightening torque (N.m)
ĭ
15~20
ĭ
30~40
ĭ
45~55
ĭ
60~65
ĭ
70~75
indoor pipe
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and
then wrap it with tape.
insulating pipe
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
drain hose
outlet pipe
2. Bind the joint with tape.
drain hose
outlet
pipe
tape
drain hose
Note:
Ɣ Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
Ɣ The plastic expansion particles are
not provided.
insulating pipe
Step seven: connect wire of indoor unit
panel
screw
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
wiring cover
7
Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
cable-cross
hole
power connection
wire
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
with wire clip.
09、12K(for some model):
N(1)
2
3
green
white black red
(brown) (yellow(blue)
green)
Outdoor unit connection
09、12、18、24K
(for some model):
L1’
S
L2’
G
green
white black red
(brown) (yellow(blue)
green)
Outdoor unit connection
1RWHWKHZLULQJERDUGLVIRUUHIHUHQFHRQO\SOHDVHUHIHUWRWKe actual one.
4.Put wiring cover back and then tighten the screw.
5.Close the panel.
Note:
Ɣ All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
Ɣ)RUWKHDLUFRQGLWLRQHUZLWKRXWSOXJDQair switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
28
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
connection pipe
drain hose
band
indoor and
outdoor power cord
indoor unit
gas
pipe
indoor power cord
liquid pipe
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
band
drain hose
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
Note:
Ɣ7KHSRZHUFRUGDQGFRQWUROZLUH
FDQ
WEHFURVVHGRUZLQGLQJ
Ɣ7KHGUDLQKRVHVKRXOGEHERXQG
at the bottom.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
upper hook
outdoor
sealing gum
lower hook of
wall-mounting frame
Note:
Ɣ'RQRWEHQGWKHGUDLQKRVHWRRH[FHVVLYHO\LQRUGHUWRSUHYHQWEORFNLQJ
29
Installation of outdoor unit
6WHSRQH¿[WKHVXSSRUWRIRXWGRRUXQLW
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
Ɣ7DNHVXI¿FLHQWSURWHFWLYHPHDVXUHVZKHQ
installing the outdoor unit.
ƔMake sure the support can withstand at least
four times of the unit weight.
Ɣ7KHRXWGRRUXQLWVKRXOGEHLQVWDOOHGDWOHDVW
FPDERYHWKHÀRRULQRUGHUWRLQVWDOOGUDLQ
joint.
Ɣ)RUWKHXQLWZLWKFRROLQJFDSDFLW\RI:
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W at least 3cm above the floor
~16000W, 10 expansion screws are needed.
6WHSWKUHH¿[RXWGRRUXQLW
Step two: install drain joint
(Only for cooling and heating
unit)
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the drain
vent.
drain vent
Drain hose
foot holes
foot holes
chassis
outdoor drain joint
30
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right handle of outdoor unit and then remove
the handle.
3. Pretightening the union nut with
hand.
pipe joint
screw
union nut
handle
2. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.
4. Tighten the union nut with torque
wrench by referring to the sheet
below.
torque
Hex nut diameter Tightening
(N.m)
ĭ
a
ĭ
30~40
ĭ
4a
ĭ
a
ĭ
a
liquid pipe
gas pipe
liquid
valve
gas valve
1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the
、12K(for some model):
N(1)
2
3
green
white
red
(yellow- (blue) black (brown)
green)
L
N
black white green
(brown) (blue) (yellowgreen)
L
、12K(for some model):
L1’
S
L1
white
(blue)
black
L2’
G
L2
G
red
(brown)
green
(yellowgreen)
18、24K:
L1’
green(yellow-green)
black(brown)
white(blue)
N
S
L2’
green
white
red
(yellow- (blue) black (brown)
green)
L2
L1
POWER
Indoor unit connection POWER
L2
L1
G
black white green
(brown) (blue) (yellowgreen)
L2
L1
Indoor unit connection POWER
Indoor unit connection
Note: the wiring board is for reference only,please refer to the actual one
31
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
Ɣ1HYHUFXWWKHSRZHUFRQQHFWLRQZLUHWRSURORQJRUVKRUWHQWKHGLVWDQFH
Step six: neaten the pipes
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
wall
U-shaped curve
drain hose
Note:
Ɣ The through-wal height of drain hose
shouldn't be higher than the outlet
pipe hole of indoor unit.
Ɣ6ODQWWKHGUDLQKRVHVOLJKWO\GRZ
nwards. The drain hose can't be
the drain hose
can't raise
upwards.
The drain hose can't be fluctuant
Ɣ The water outlet can't be placed
in water in order to drain smoothly.
The drain hose
can't be fluctuant
The water outlet
can't be placed
in water
32
The water
outlet can't be
fluctuant
Vacuum pumping
Use vacuum pump
1. Remove the valve caps on
liquid valve
the liquid valve and gas
piezometer
Lo
Hi
valve and the nut of refrigas valve
gerant charging vent.
valve cap
2. Connect the charging ho- refrigerant charging
vent
se of piezometer to the
refrigerant charging vent
nut of refrigerant
of gas valve and then co- charging vent
nnect the other charging
vacuum pump
hose to the vacuum pump.
3. Open the piezometer cominner hexagon
pletely and operate for
spanner
10-15min to check if the
pressure of piezometer remains in -0.1MPa.
close
4. Close the vacuum pump
open
and maintain this status for
1-2min to check if the pressure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
33
Check after installation
Ɣ&KHFNDFFRUGLQJWRWKHIROORZLQJUHTXLUHPHQWDIWHU¿QLVKLQJLQVWDOODWLRQ
Items to be checked
Possible malfunction
+DVWKHXQLWEHHQLQVWDOOHG¿UPO\"
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
(heating) capacity.
,VKHDWLQVXODWLRQRISLSHOLQHVXI¿FLHQW"
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
Is the voltage of power supply according to the voltage marked on the
nameplate?
It may cause malfunction or damaging
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speci¿FDWLRQ"
It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet?
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts.
The gas valve and liquid valve of
connection pipe are open completely?
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
(heating) capacity.
Test operation
1. Preparation of test operation
Ɣ7KHFOLHQWDSSURYHVWKHDLUFRQGLWLRQHU
Ɣ6SHFLI\WKHLPSRUWDQWQRWHVIRUDLUFRQGLWLRQHUWRWKHFOLHQW
2. Method of test operation
Ɣ3XWWKURXJKWKHSRZHUSUHVV212))EXWWRQRQWKHUHPRWHFRQWUROOHUWRVWDUW
operation.
Ɣ3UHVV02'(EXWWRQWRVHOHFW$872&22/'5<)$1DQG+($7WRFKHFN
whether the operation is normal or not.
Ɣ,IWKHDPELHQWWHPSHUDWXUHLVORZHUWKDQć , the air conditioner can’t
start cooling.
34
Configuration of connection pipe
1. Standard length of connection pipe
ƔPPP
0LQOHQJWKRIFRQQHFWLRQSLSHLVP
0D[OHQJWKRIFRQQHFWLRQSLSHDQGPD[KLJKGLfference.
Cooling
FDSDFLW\
Max length
Max height
of connecdifference
tion pipe
Cooling
FDSDFLW\
Max length
Max height
of connecdifference
tion pipe
%WXK
:
%WXK
:
10
%WXK
:
%WXK
:
10
%WXK
:
%WXK
:
20
%WXK
:
20
10
%WXK
:
20
%WXK
:
10
%WXK
:
20
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
Ɣ $IWHUWKHOHQJWKRIFRQQHFWLRQSLSHLVSURORQJHGIRUPDWWKHEDVLVRI
VWDQGDUGOHQJWK\RXVKRXOGDGGPORIUHIULJHUDQWRLOIRUHDFKDGGLWLRQDOP
of connection pipe.
Ɣ The calculation Pethod of additional refrigerant charging DPount (on the Easis
of liquid pipe):
$GGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW = prolonged length of liquid pipe ×
DGGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQWSHUPHWHU
Ɣ%DVLQJRQWKHOHQJWKRIVWDQGDUGSLSHDGGUHIULJHUDQWDFFRUGLQJWRWKH
UHTXLUHPHQWDVVKRZQLQWKHWDEOH7KHDGGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW
SHUPHWHULVGLfIHUHQWDFFRUGLQJWRWKHGLDPHWHURIOLTXLGSLSH6HHWKH
following sheet.
5
&RQ¿JXUDWLRQRIFRQQHFWLRQSLSH
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Outdoor unit throttle
Liquid pipe(mm)
Gas pipe(mm)
ĭ
ĭRUĭ
20
ĭRUĭ
ĭRUĭ
ĭ
ĭRUĭ
30
120
ĭ
ĭRUĭ
120
ĭ
_
ĭ
_
Cooling only(g/m) Cooling and heating(g/m)
36
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
E: Expand the port
Ɣ([SDQGWKHSRUWZLWKH[SDQGHU
A: Cut the pipe
Ɣ&RQ¿UPWKHSLSHOHQJWKDFFRUGLQJWR
the distance of indoor unit and
outdoor unit.
Ɣ&XWWKHUHTXLUHGSLSHZLWKSLSHFXWWHU
hard
mold
expander
pipe
pipe
pipe cutter
leaning
uneven
Note:
Ɣ$LVGLIIHUHQWDFFRUGLQJWRWKH
diameter, please refer to the sheet
below:
burr
B: Remove the burrs
Ɣ5HPRYHWKHEXUUVZLWKVKDSHUDQG
prevent the burrs from getting into
the pipe.
pipe
shaper
downwards
A(mm)
Outer diameter
(mm)
Max
Min
ĭ
1.3
0.7
ĭ
1.6
1.0
ĭ
1.8
1.0
ĭ
2.4
2.2
F: Inspection
Ɣ&KHFNWKHTXDOLW\RIH[SDQGLQJSRUW
If there is any blemish, expand the
port again according to the steps
above.
C: Put on suitable insulating pipe
D: Put on the union nut
Ɣ5HPRYHWKHXQLRQQXWRQWKHLQGRRU
connection pipe and outdoor valve;
install the union nut on the pipe.
smooth surface
improper expanding
union pipe
leaning
pipe
the length is equal
37
damaged
surface
crack
uneven
thickness
Wired Controller
If the product you bought is equipped with wired controller, please
refer to the following introductions of wired controller.
1 Displaying Part
Fig1.1.1 Outline of wired controller
1.1 LCD Display of Wired Controller
Fig.1.1.2 LCD display
38
Wired Controller
1.2 Instruction to LCD Display
Table 1.1
No.
Symbols
Description
1
Swing function
2
Air exchange function (this function is yet unavailable for this unit).
3
Sleep function (Only sleep 1).
4
Each kind of running mode of indoor unit (auto mode)
5
Cooling mode
6
Dry mode
7
Fan mode
8
Heating mode
9
Defrosting function for the outdoor unit.
10
Gate-control function (this function is yet unavailable for this unit).
11
Lock function.
12
SHIELD
13
Turbo
14
MEMORY
15
16
Turbo function state
Memory function (The indoor unit resumes the original setting state after
power failure and then power recovery).
It blinks under on state of the unit without operation of any button.
SAVE
17
Energy-saving function (this function is yet unavailable for this unit).
Ambient/setting temperature value
18
E-HEATER
19
BLOW
20
21
Shield functions (Button operation, temperature setting, On/Off operation,
Mode setting are disabled by the remote monitoring system.)
Electric auxiliary heating function.
Blow function.
Timing value.
QUIET
Quiet function (two types: quiet and auto quiet)
(this function is yet unavailable for this unit).
39
Wired Controller
2 Buttons
2.1 Layout of Buttons
2.2 Functions of Buttons
Table 2.1
No.
Name
1
Enter/Cancel
2
Ÿ
Function
Function selection and cancellation.
ķ .Running temperature setting of the indoor unit, range:16~30oC.
ĸ .Timer setting, range:0.5-24 hr.
6
ź
3
Fan
4
Mode
5
Function
7
Timer
Timer setting.
8
On/Off
Turn on/off the indoor unit
4+2
Ÿ0RGH
3+6
)DQź
2+6
Ÿź
Setting of the high/middle/low/auto fan speed.
Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
Switchover among the functions of Turbo/Save/E-heater/Blow etc..
Press them for 5s under off state of the unit to enter/cancel the Memory
function(If memory is set, indoor unit after power failure and then power
recovery will resume the original setting state. If not, the indoor unit is
defaulted to be off after power recovery. Memory off is default before
delivery.).
By pressing them at the same time under off state of the unit,
will be
will be
displayed on the wired controller for the cooling only unit, while
displayed on the wired controller for the cooling and heating unit.
Upon startup of the unit without malfunction or under off state of the
unit,press them at the same time for 5s to enter the lock state, in which
case,any other buttons won’t respond the press. Repress them for 5s to quit
this state.
40
Wired Controller
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit and turn it off by another press.
Note: The state shown in Fig.3.1.1 indicates the “Off” state of the unit after power on. The state
shown in Fig.3.1.2 indicates the “On” state of the unit after power on.
Fig.3.1.1 “Off” State
Fig.3.1.2 “On” State
3.2 Mode Setting
Under ON state of the unit, press the Mode to switch the operation modes as the following
sequence: Auto–Cooling–Dry–Fan–Heating.
3.3 Temperature Setting
Press Ÿor ź to increase/decrease the preset temperature. If pressing either of them
continuously, the temperature will be increased or decreased by 1°C every 0.5s,as shown in
Fig.3.3.1.
In the Cooling, Dry, Fan or Heating mode, the temperature setting range is 16°C~30°C.
In the Auto mode, the setting temperature is unadjustable.
Fig.3.3.1
Fig.3.4.1
41
Wired Controller
3.4 Fan Setting
Under the “On” state of the unit, press Fan and then fan speed of the indoor unit will change
circularly as shown in Fig.3.4.1.
Low
Middle
High
3.5 Timer Setting
Under on-state of the unit, Press Timer button to set timer off of the unit. Under off-state of the
unit, press Timer button to set timer on of the unit in the same way.
‡ Timer on setting:
Under off-state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
Hour,with ON blinking. In this case, SUHVVŸ or ź button to adjust timer on and then press Timer to
‡ Timer off setting:
Under on-state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
HourZLWK2))EOLQNLQJ,QWKLVFDVHSUHVVŸRUźEXWWRQWRDGMXVWWLPHURQDQGWKHQSUHVV Timer to
‡&DQFHOWLPHU
After setting of timer, if Timer button is pressed, LCD won’t display xx. Hour so that timer setting
is canceled.
Timer off setting under the “On” state of the unit is shown as Fig.3.5.1.
Fig.3.5.1 Timer off Setting under the “On” State of the Unit
42
Wired Controller
Timer on setting under the “Off” state of the unit is shown as Fig.3.5.2.
Fig.3.5.2 Timer on Setting under the “Off” State of the Unit
Timer range: 0.5-24hr. Every press of ŸRU ź will make the set time increased or decreased by
0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every
0.5s.
43
Wired Controller
3.6 Swing Setting
Swing On: Press Function under on state of the unit to activate the swing function. In this case,
Swing Off: When the Swing function is on, press Function to enter the Swing setting
blinking. After that, press Enter/Cancel to cancel this function. Swing setting is
interface,with
shown as Fig.3.6.1.
Fig.3.6.1 Swing Setting
Notes:
ķ . Sleep, Turbo or Blow setting is the same as the Swing setting.
ĸ . After the setting has been done, it has to press the key “Enter/Cancel” to back to the setting
44
Wired Controller
3.7 Sleep Setting
Sleep on: Press Function under the On state of the unit till the unit enters the Sleep setting
Sleep off: When the Sleep function is activated, press Function to enter the Sleep setting
status. After that, press Enter/Cancel to cancel this function.
In the Cooling or Dry mode, the temperature will increase by 1°C after the unit runs under
Sleep1 for 1hr and 1°C after another 1hr.After that, the unit will run at this temperature.
In the Heating mode, the temperature will decrease by 1°C after the unit runs under Sleep 1 for
1hr and 1°C after another 1hr. After that, the unit will run at this temperature.
Sleep setting is shown as Fig.3.7.1.
Fig.3.7.1. Sleep Setting
45
Wired Controller
3.8 Turbo Setting
Turbo function: The unit at the high fan speed can realize quick cooling or heating so that the
room temperature can quickly approach the setting value.
In the Cooling or Heating mode, press Function till the unit enters the Turbo setting status and
When the Turbo function is activated, press Function to enter the Turbo setting status and then
press Enter/Cancel to cancel this function.
Turbo function setting is as shown in Fig.3.8.1.
Fig.3.8.1 Turbo Setting
46
Wired Controller
3.9 E-heater Setting
E-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to be
Once the wired controller or the remote controller enters the Heating mode, this function will be
turned on automatically.
Press Function in the Heating mode to enter the E-heater setting interface and then press
Enter/Cancel to cancel this function.
Press Function to enter the E-heater setting status, if the E-heater function is not activated,
and then press Enter/Cancel to activate it.
The setting of this function is shown as Fig.3.9.1 below:
Fig.3.9.1 E-heater Setting
47
Wired Controller
3.10 Blow Setting
Blow function: After the unit is turned off, the water in evaporator of indoor unit will be
automatically evaporated to avoid mildew.
In the Cooling or Dry mode, press Function till the unit enters the Blow setting status and then
press Enter/Cancel to active this function.
When the Blow function is activated, press Function to the Blow setting status and then press
Enter/Cancel to cancel this function.
Blow function setting is as shown in Fig.3.10.1
Fig.3.10.1 Blow Setting
Notes:
ķ . When the Blow function is activated, if turning off the unit by pressing On/Off or by the
remote controller, the indoor fan will run at the low fan speed for 2 min, with “BLOW” displayed on
the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly.
ĸ . Blow function is unavailable in the Fan or Heating mode.
48
Wired Controller
3.11 Other Functions
a. Lock
Upon startup of the unit without malfunction or under the “Off” state of the unit, press Ÿ and źat
the same time for 5s till the wired controller enters the Lock function. In this case, LCD displays
.
After that, repress these two buttons at the same time for 5s to quit this function.
Under the Lock state, any other button press won’t get any response.
b. Memory
Memory switchover: Under the “Off” state of the unit, press Mode and Ÿ at the same time for
5s to switch memory states between memory on and memory off. When this function is activated,
Memory will be displayed. If this function is not set, the unit will be under the “Off” state after power
failure and then power recovery.
Memory recovery: If this function has been set for the wired controller, the wired controller after
power failure will resume its original running state upon power recovery. Memory contents: On/
Off, Mode, set temperature, set fan speed and Lock function.
4 Installation and Dismantlement
4.1 Connection of the Signal Line of the Wired Controller
Ɣ2SHQWKHFRYHURIWKHHOHFWULFFRQWUROER[RIWKHLQGRRUXQLW
Ɣ/HWWKHVLQJOHOLQHRIWKHZLUHGFRQWUROOHUWKURXJKWKHUXEEHUULQJ
Ɣ&RQQHFWWKHVLJQDOOLQHRIWKHZLUHGFRQWUROWRWKHSLQVRFNHWRIWKHLQGRRUXQLW3&%
Ɣ Tighten the signal wire with ties.
Ɣ The communication distance between the main board and the wired controller can be up to
20 meters ( the standard distance is 8 meters)
4.2 Installation of the Wired Controller
39&3LSH
1
2
3
4
5
Fig.4.1 Accessories for the Installation of the Wired Controller
Table 4.1
No.
1
2
3
4
5
Name
6RFNHWER[
embedded
in the wall
Soleplate of
the Wired
Controller
Screw
M4X25
)URQW3DQHO
of the Wired
Controller
Screw
ST 2.9X6
49
Wired Controller
3
2
1
6
7
8
9
4
5
10
Fig.4.2
Fig.4.2 shows the installation steps of the wired controller, but there are some issues that need
your attention.
1) Prior to the installation, please firstly cut off the power supply of the wire buried in the
installation hole, that is, no operation is allowed with electricity during the whole installation.
2) Pull out the four-core twisted pair line from the installation holes and then let it go through
the rectangular hole behind the soleplate of the wired controller.
with screws M4X25.
4) Insert the four-core twisted pair line into the slot of the wired controller and then buckle the
front panel and the soleplate of the wired controller together.
CAUTION!
Please pay special attention to the followings during the connection to avoid the malfunction of
the air conditioning unit due to electromagnetic interference.
ķ . Separate the signal and communication lines of the wired controller from the power cord
50
Wired Controller
and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm,
otherwise the communication of the unit will probably work abnormally.
ĸ . If the air conditioning unit is installed where is vulnerable to electromagnetic
interference,then the signal and communication lines of the wired controller must be the shielding
twisted pair lines.
4.3 Dismantlement of the Wired Controller
1
2
3
4
5 Errors Display
If there is an error occurring during the operation of the system, the error code will be displayed
on the LCD, as show in Fig.5.1. If multi errors occur at the same time, their codes will be displayed
circularly.
Note: In event of any error, please turn off the unit and contact the professionally skilled
personnel.
Fig.5.1
51
Wired Controller
Table 5.1 Meaning of Each Error
Error
Return air temperature sensor open/
short circuited
evaporator temperature sensor open/
short circuited
Indoor unit liquid valve temperature
sensor open/short circuited
Indoor gas valve temperature sensor
open/ short circuited
IPM temperature sensor open/short
circuited
Outdoor ambient temperature sensor
open/ short circuited
Outdoor unit condenser mid-tube
temperature sensor open/short circuited
Discharge temperature sensor open/
short circuited
Error
Code
Error
Error
Code
F1
Drive board communication error
P6
F2
Compressor overheating protection
H3
b5
Indoor and outdoor units unmatched
LP
b7
Communication line misconnected or
expansion valve error
dn
P7
E7
F3
Pump-down
Fo
F4
Jumper error
C5
F5
Forced defrosting
H1
Indoor and outdoor communication error
E6
Compressor startup failure
Lc
DC bus under-voltage protection
PL
High discharge temperature protection
E4
DC bus over-voltage protection
PH
Overload protection
E8
Compressor phase current sensing
circuit error
U1
Whole unit over-current protection
E5
Compressor demagnetization protection
HE
Over phase current protection
P5
PFC protection
Hc
Compressor desynchronizing
H7
IPM Temperature Protection
P8
IPM Current protection
H5
Compressor phase loss/reversal
protection
Frequency restricted/reduced with whole
unit current protection
Frequency restricted/reduced with IPM
current protection
Frequency restricted/reduced with high
discharge temperature
Frequency restricted/reduced with antifreezing protection
Frequency restricted/reduced with
overload protection
Frequency restricted/reduced with IPM
temperature protection
Ld
Over-power protection
L9
System charge shortage or blockage
protection
F0
Capacitor charging error
PU
High pressure protection
E1
Low pressure protection
E3
Compressor stalling
LE
Over-speeding
LF
Drive board temperature sensor error
PF
Indoor unit full water error
E9
AC contactor protection
P9
Anti-freezing protection
E2
Temperature drift protection
PE
AC input voltage abnormal
PP
Sensor connection protection
Pd
Whole unit current sensing circuit error
U5
DC bus voltage drop error
U3
4-way valve reversing error
U7
Outdoor fan 1 error protection
L3
Motor stalling
H6
Outdoor fan 2 error protection
LA
PG motor zero-crossing protection
U8
52
F8
En
F9
FH
F6
EU
66129917776
Was this manual useful for you? yes no
Thank you for your participation!