Descaling your Oracle
™
Espresso Machine
Applicable to PDC code 1534 to current
NOTE
Only descale your Oracle via the descale menu.
2 – Empty Boilers a) Remove the grey silicone cover on the lower front panel marked DESCALE ACCESS.
1 – Prepare for Descale a) Empty the drip tray and insert into position.
b) With the machine off, press and hold the 1 CUP button, then press and hold the POWER button together for 3 seconds. rSEt will appear on the LCD.
THEN PRESS
& HOLD
REMOVE
b) Place a cloth over the drip tray to prevent steam escaping.
POWER c) Rotate SELECT dial until ‘dESC” appears on
LCD and press the dial to confirm.
c) Use a flat head screw driver to rotate the right valve counter-clockwise SLOWLY until fully open. As the valve opens, steam may be released.
NOTE
If there’s no water released into the drip tray, press and hold the 1 CUP button for
3 seconds. This will release water from the boiler.
When the water is completely empty, close the valve by rotating screws clock-wise until seated. Do not overtighten screws to avoid damages to the valves.
Allow the countdown timer to reach 0 as this allows solution sufficient time to dissolve scale build up. However you can proceed to the next step at any time by pressing the 1 Cup button.
b) Place a cloth over the drip tray to stop steam escaping.
c) Empty boilers by repeating steps 2c and 2d.
d) Empty drip tray and insert back to place.
e) Empty water tank then rinse and fill with clean water to the MAX line. Lock water tank back into position.
4 – Flush Boilers a) Press 1 Cup button and the LCD screen will show countdown time (20 minutes). d) Repeat the above process on the left valve.
e) Empty the drip tray, use caution as the drip tray may be hot.
f) Empty water tank, remove water filter.
g) Dissolve 1 sachet of Sage Descaler
™
into
1 litre of warm water. Pour solution into the water tank.
NOTE
If water tank has not been removed, replaced or is empty, “FILL TANK” will appear on the LCD.
3 – Begin Descale a) Press 1 Cup button and the LCD screen will show countdown time (20 minutes).
During this time, the machine will fill boilers with descale solution and heat to temperature.
There may be some water flow through the group head during this time.
During this time, the machine will fill boilers with fresh clean water and heat to temperature.
You can proceed to the next step at any time by pressing the 1 Cup button.
b) Place a cloth over the drip tray to stop steam escaping. c) Empty boilers by repeating steps 2c and 2d.
d) Empty drip tray and insert back to place.
e) Empty water tank then rinse and fill with clean water to the MAX line. Lock water tank back into position.
5 – Repeat Step 4 Flush Boilers
We recommend flushing boilers again to ensure any residual descale solution is released from the boilers.
Press POWER button to escape the Descale mode. The descale process is now complete and ready to use.
A15