All Installations:
During any ULC Installation described within this Guide, all the rules for safe installation specified in the CEC (Canadian Electrical Code) shall be respected. This
guide is intended to be used in conjunction with the following DSC alarm control panel models unless otherwise stated: MAXSYS (PC4020), PowerSeries
(PC1864/PC1832/PC1616), PowerSeries Neo (HS2128/HS2064/HS2032/HS2016). Always use this guide in conjunction with the installation manual of mentioned alarm control panel.
• For mounting on the exterior of vault, safe, or stockroom, installation of vibration detector is required. (s304, 8.1.5)
• Transformer: Plug-in type or hardwired, minimum rated 16.5VAC, 37- 40VA Class 2 Power limited, CSA/cETL/cUL Listed. Refer to product installation manual
for acceptable models. Note: Do not mount the hardwired transformer inside the DSC enclosure models PC5003C, PC4050C.
• Install with ULC Listed devices where applicable.
Requirements
Minimum Battery Standby
Battery Size
Note: Battery capacity can
be selected based on calculated AUX current
consumption for the system (including all
accessories).
Household Burglary
Household Fire
Central Station
Burglary Monitoring
Central Station Fire Monitoring
Local Burglary
(only applicable to
MAXSYS Systems)
4 Hour
24 Hour
24 Hour
24 Hour
24 Hour
12V/4Ah
1 x 12V/7Ah
or
2 x 12V/7Ah
1 x 12V/7Ah
or
2 x 12V/7Ah
1 x 12V/7Ah
or
2 x 12V/7Ah
1 x 12V/7Ah
or
2 x 12V/7Ah
 45 s
not applicable
programmable
not applicable
 seconds
 60 seconds
not applicable
programmable
not applicable
45 seconds
4 minutes
5 minutes
programmable
not applicable
bell should not sound
programmable
Equipment Standard
ORD-C1023-1974
CAN/ULC-S545-02
CAN/ULC-S304-06
CAN/ULC-S559-04
CAN/ULC-S303
Installation Standard
CAN-ULC-S310
CAN/ULC-S540
CAN/ULC-S302
CAN/ULC-S561-03
CAN/ULC-S302
Enabled
Enabled
Enabled *see Note 1
Enabled *see Note 2
Optional
System Entry Delay
System Exit Delay
Minimum Bell Cutoff Time
Communicator
ULC Marking
Note: For residential
installation the commercial type marking is
also acceptable (Subscribers' Unit).
Power LED (Model ULC-LA)
(Not required if PK/RFK55XX keypads with
AC indicator enabled are being used.)
AC Power
Tamper Protection
Cabinet
Note: ULC marking might be applied on the
outside of the enclosure or inside on the PCB
assembly.
Special Notes
Household Burglary
Household Fire
Subscribers' Unit BurSubscribers' Unit Fire
Local Burglar Alarm
Alarm System
Warning Alarm System
glary or Subscribers'
Alarm or Subscribers'
Control Unit
Control Unit
Unit-Accessory Burglary Unit-Accessory Fire Alarm
Optional
Required
Required
Required
Required
Plug-in transformer
Optional hardwired
connection
Plug-in transformer
Optional hardwired
connection
Plug-in transformer
Optional hardwired
connection
Hardwired connection
required
Check local authority
Plug-in transformer
Optional hardwired
connection
Optional
Optional
Required *see Note 8
Optional
Required *see Note 8
DSC Models
PC5003C
PC500C
Concourse
DSC Models
PC5003C
PC4050C
Concourse
DSC Models
PC5003C
PC4050C
DSC Models
PC5003C/PC4050C/
PC4050CR (Red)
Note: Do not install the
hardwired transformer in
the PC5003C and
PC4050C enclosures.
DSC Models
(Attack Resistant)
CMC-1
PC4050CAR
------------
*see Note 4
*see Note 5
*see Notes 3 & 7
*see Notes 5 & 6
*Notes:
Note 1: Communication Channel Security (applicable to Commercial Burglary/Financial Installations
Passive Levels
Note: Test
Transmission required every 24h
(on each communication channel)
Transmitter(s)
Equipment at
Protected Premises
P1
One communication channel:
Dialer (PC4020/PC1864/1832/1616, HS2128/2064/2032/2016)
GSM (GS3055/GS3060/3G3070/3G3070-RF/TL260GS/GS2060/
3G2080/3G2080R/TL2803G/TL2803GR)
IP (T-Link TL250/TL300/TL260/TL260GS/3G2060/3G2060R/TL260/
TL260R/TL280/TL280R/TL2803G/TL2803GR)
P2
Communication channels:
Dialer and GSM back-up, Dialer and IP back-up, GSM and Dialer
back-up, IP and Dialer back-up, IP and GSM back-up, GSM and IP
back-up. Refer to diagrams 3, 6, 7, 10.
P3
Supervision of
Communication
Channel(s)
Receiver
Equipment at Signal
Receiving Centre (SRC)
Loss of communicaSG-MLR2-DG/
tion channel shall
SG-MLR2000 /
initiate local trouble
SG-System IV /
signal within
SG-System III /
180 seconds
SG-System II / SG-System I
Failure of either
channel shall be
reported to the SRC
within 240 seconds
Risk
Levels
Low
SG-MLR2-DG /
Medium
SG-MLR2000 /
SG-System IV /
SG-System III /
SG-System II / SG-System I
Dual Communication System:
Failure of either
SG-MLR2-DG /
GSM and IP, Dialer and IP, Dialer and GSM
channel shall be
SG-MLR2000 /
Status change signals shall be sent simultaneously over both communi- reported to the SRC
SG-System IV /
cation channels. Refer to diagrams 3, 6, 7, 10, 11. Use separate PGM within 240 seconds
SG-System III /
outputs programmed to activate for each type of event identified as a
SG-System II / SG-System I
status change signal: Burglar Alarm, Holdup, Duress, Tamper, Opening/
Closing.Use zone expander where more zone inputs are required to
accommodate the transmission of these signals.
High
Notes: The telephone service should be of a type that provides for timed release disconnect, in order to give the digital alarm communicator transmitter (dialer) the ability to disconnect an incoming call to the protected premises.
If the lines (numbers) are in a single hunt group, they shall be individually accessible; otherwise, separate hunt groups shall be required. These lines shall be used for no other purpose than receiving signals from a digital alarm communicator transmitter. These lines (numbers) shall be unlisted. A timed release disconnect requirement applies to the telephone
lines (numbers) connected to the digital alarm communicator receiver. The numbers assigned to the digital alarm communicator receiver shall be individually accessible, even where
they are connected in rotary (hunt group).
Models SG-MLR2-DG and SG-MLR2000 Receivers (DACR type) are legacy products that are still used by some ULC Listed Signal Receiving Centres.
29002157R015
Active Levels
Note: Check-in/Polling signal required
every 90 seconds.
Transmitter(s) Equipment at Protected Premises
Supervision of Communication Channel(s)
Receiver Equipment at Signal Receiving Centre (SRC)
Risk
Levels
Back-up
Requirements
for Network
Equipment
Low
24h standby
power or dialer
as back-up
A1
IP (T-Link TL250/TL300, TL260/TL260GS/TL260R/
Loss of communication
SG-System IV
TL2603G/TL2603GR/TL280/TL280R/TL2803G/TL2803GR) channel shall be indicated
SG-System III
GSM/HSPA (GS2060/3G2060/3G2060R/3G2080/
at SRC within 180 secSG-System II
3G2080R/TL2803G/TL2803GR)
onds
SG-System I
AES 128bit encryption; Refer to diagrams 2, 4, 5, 10
(512 supervised transmitters)
A2
IP (T-Link TL250/TL300, TL260/TL260GS/TL260R/
TL2603G/TL2603GR/TL280/TL280R/TL2803G/TL2803GR)
GSM/HSPA (GS2060/3G2060/3G2060R/3G2080/
3G2080R/TL2803G/TL2803GR)
AES 128bit encryption; Refer to diagrams 2, 4, 5, 10
A3
IP (T-Link TL250/TL300, TL260/TL260GS/TL260R/
Loss in 180 seconds at
TL2603G/TL2603GR/TL280/TL280R/TL2803G/TL2803GR) SRC; compromise detecGSM/HSPA (GS2060/3G2060/3G2060R/3G2080/
tion and identification at
3G2080R/TL2803G/TL2803GR)
SRC
AES 128bit encryption; Refer to diagrams 2, 4, 5, 10
180 seconds
SG-System IV
High /
24h standby
SG-System III
Financial power or GSM
SG-System II
and High
as back-up
SG-System I
Value
(512 supervised transmitters)
Asset
A4
IP (T-Link TL250/TL300, TL260/TL260GS/TL260R/
Loss in 180 seconds at
TL2603G/TL2603GR/TL280/TL280R/TL2803G/TL2803GR) SRC; compromise detecGSM/HSPA (GS2060/3G2060/3G2060R/3G2080/
tion and identification at
3G2080R/TL2803G/TL2803GR)
SRC
AES 128bit encryption; Refer to diagrams 2, 4, 5, 10
180 seconds
SG-System IV
Very High
SG-System III
SG-System II
SG-System I
(512 supervised transmitters)
Loss in 180 seconds at
SRC;
Identification at SRC;
Compromise detection
240 seconds
SG-System IV
Medium 24h standby
SG-System III
power or dialer
SG-System II
as back-up
SG-System I
(512 supervised transmitters)
24h standby
power
Note: For equipment used at the protected premises or SRC and intended to facilitate IP communications (hubs, routers, NID, DSL/Cable modems) 24h back-up power
is required. Where such cannot be facilitated, a secondary (back-up) communication channel is required.
Notes for using Private, Corporate and High Speed Data Networks: Network access and domain access policies shall be set to restrict unauthorized network
access, and “spoofing” or “denial of service” attacks. Select the internet service providers that have redundant servers/systems, back-up power, routers with firewalls
enabled and methods to identify and protect against “denial of service” attacks (i.e., via “spoofing”).
Notes for using Public Switched and Wireless Data Networks: Communication channels shall be facilitated such that the communicator will restrict unauthorized
access, which could otherwise compromise security.
Note 2: Fire Monitoring Communication Systems (Refer to the wiring diagrams in this guide for possible configurations)
Fire alarms shall be received at SRC in 60 seconds. Trouble signals shall be received at SRC in 90 seconds.
Type
Transmitter(s) Equipment at
Protected Premises
Passive
Dual Communication System:
Dual Dialer (PC4701/PC5700)
Note: Test Transmission
Note: Subject to AHJ approval
required every 24h (on
Dialer with GSM, Dialer with IP
each communication
Fire Alarms shall be sent simultaneously over both communication channels
channel).
Supervision of
Communication Channel(s)
Receiver Equipment at Signal
Receiving Centre (SRC)
Failure of either channel shall be SG-MLR2-DG / SG-MLR2000 /
reported to the SRC within 180 SG-System IV / SG-System III /
seconds.
SG-System II / SG-System I
Failure of both channels shall be
indicated locally in 240 seconds.
Active
IP (T-Link TL250/TL300/TL260/TL260GS/TL2603G/TL2603GR/TL260R/
Loss of communication channel
TL280/TL280R/TL2803G/TL2803GR)
shall be indicated at SRC within
Note: Check-in/Polling
180 seconds.
signal required every 90 GSM (GS2060/3G2060/3G2060R/3G2080/3G2080R/TL2803G/TL2803GR)
optional AES 128bit encryption
seconds.
SG-System IV / SG-System III /
SG-System II / SG-System I
(512 supervised transmitters)
Note: Models SG-MLR2-DG, SG-MLR2000 are not ULC Listed under the ULC-S559-04 requirements. Dual dialer is not for use with PowerSeries Neo panels.
Note 3: Each ULC labelled “Subscribers' Unit Fire and/or Burglary” communication system shall be connected to a ULC labelled “Fire Alarm Control
Unit” if they are to monitor a complete fire alarm system. As minimum, system fire alarms, supervisory and troubles signals shall be transmitted to the
SRC.
Note 4: Program input zones as Fire Type for connection of ULC labelled 4-wire smoke detectors (e.g., DSC FSA-410A series) or program PGM 2 for
connection of compatible ULC labelled 2-wire smoke detectors (e.g., DSC FSA-210A series). Refer to Zone Wiring Diagrams in this guide.
Note 5: Double end-of-line zone configuration must be used for Medium, High and Very High Risk Installations (refer to Zone Wiring Diagrams in this
guide for possible configurations).
Note 6: Only one contact per zone (refer to Zone Wiring Diagrams for double door/window contact in this guide).
Note 7: For financial/bank applications when mounting the control panel on the exterior of a vault, safe, or stockroom, installation of vibration detector is required. Recommended assault sensor UTC, model 5422.
Note 8: This may be connected to ULC labelled Sprinkler Riser devices (refer to Zone Wiring Diagrams in this guide).
Note 9: All system enclosures must be 24-hour tamper protected against opening or removal (DSC Tamper Kit T-1 or equivalent). This includes control
unit and accessory cabinets, transmitters, initiating devices and bells/strobes. Keypads must be tampered if they use a zone input or if they are installed
outside the protected area.
Note 10: When performing the test for loss of communications channel on a TL2603G(R), 3G2060(R), TL2803G(R) or 3G2080(R), it is recommended
that you remove the SIM card from the communicator to simulate loss of communications. Removing the antennae is not an acceptable method for
testing as the 3G radio used in this product may be able to communicate without the antennae connected.
Programming
The notes in the installation and programming sections describing the system configurations for ULC Listed installations must be implemented.
Protection of the Control Unit - Burglary
The local control unit and local power supply must be protected in one of the following ways:
• The control unit and power supply must be located within the area of greatest protection on a tamper protected circuit.
• Each partition shall arm the area protecting the control unit and the audible alarm device power supply. This may require duplicate protection armed
by each partition. Access to this protected area, without causing an alarm, will require that all partitions are disarmed.
In all cases described above, the protected area for the control unit must be programmed so that it cannot be bypassed, and installed in accordance
with CAN/ULC-S302 or CAN/ULC-S310.
User Information
The installer should advise the users and note the following in the user instruction manual:
• Service organization name and telephone number
• The programmed exit time
• The programmed entry time
• Safety precautions specified for the connected equipment
Products or components of products, which perform communications functions only, shall comply with the requirements applicable to communications equipment as specified in CAN/CSA-C22.2 No. 60950-1, Information Technology Equipment-Safety - Part 1: General Requirements.
Zone Wiring Diagrams
4-Wire Smoke Detectors
Double End-of-line Zone Configuration
2-Wire Smoke Detectors
Double End-of-line Zone Configuration
Water Flow Connection
Double End-of-line Zone Configuration
NOTE: Reference to WF terminal block designation is only specific to certain DSC modules (MAXSYS system), the PowerSeries
and PowerSeries Neo control panels can use any zone programmed as type 24-Hr Sprinkler when used in conjunction with
a sprinkler supervision system.
Double End-of-line Zone Configuration
Double End-of-line Zone Configuration
NOTE: The tamper and relay contacts (NC) used in door/window
detectors or motion detectors are shown as the product is powered-up and in normal supervisory condition.
Double End-of-line Zone Configuration
Fire Monitoring Communication Systems Wiring Diagrams
Notes:
• These wiring diagrams are also representative for Commercial Burglary Monitoring applications.
• Either RM1C ULC OR RM2 relays can be used for ULC installations.
• Recommended DSC power supply models: PC5204/PC5200/PC4204CX/HSM2204/HSM2300.
• Refer to power supply installation manual for compatible control panels.
1. DSC Subscribers' Unit Fire and Dual Dialer (Passive Communication System)
DSC
Subscribers’
Unit Fire
Fire Alarm
Control Unit
Outputs
Fire
Supervisory
Trouble
LINE 1 to PSTN
Dual Dialer
Keybus/
Combus
Zone Inputs
LINE 2 to PSTN
PC4020
PC1864
PC1832
PC1616
PC4701
PC5700
PC4050CR cabinet
AC Input
Notes:
- This configuration falls under the exception of ULC-559 and
ULC-S561 and its use is subject to approval by ULC Inspector
and/or AHJ. This configuration can be used only if the PSTN is
the only communication technology available on the premises.
- All wiring connections shall be run in a mechanically protective
conduit.
- 24hr Test Transmission shall be enabled.
- Dry contact outputs from ULC Listed Fire Alarm Control Unit
shall be connected to Zone inputs on the ULC Listed DSC
Subscribers’ Unit Fire.
AC Input
DSC Keypad
LCD4501
PK55XX
2. DSC Subscribers' Unit Fire and IP Transmitter (Active Communication System)
DSC
Subscribers’
Unit Fire
Fire Alarm
Control Unit
Outputs
Fire
Supervisory
Trouble
Zone Inputs
PC4020
PC1864
PC1832
PC1616
PC-Link
IP
Transmitter
Router/
Modem
Power
Internet/
Intranet
T-Link TL250
PC4050CR cabinet
AC Input
AC Input
DG009380
DSC Keypad
LCD4501
PK55XX
Notes:
- All wiring connections shall be run in a mechanically protective
conduit
- T-Link TL250 Supervision at Signal Receiving Centre (SRC)
shall be enabled (180 Sec.)
- Dry contact outputs from ULC Listed Fire Alarm Control Unit
shall be connected to Zone inputs on the ULC Listed DSC
Subscribers’ Unit Fire.
3. DSC Subscribers' Unit Fire and IP Transmitter (Passive Communication System)
Fire Alarm
Control Unit
DSC
Subscribers’
Unit Fire
Outputs
Fire
Supervisory
Trouble
PC-Link
Power
12V/275mA
IP
Transmitter
T-Link TL250
PSTN
TIP
RNG
PGM1
RM1C ULC
Relay
PC4050CR cabinet
AC Input
Internet/
Intranet
Zone 1 Input
Zone Inputs
PC4020
PC1864
PC1832
PC1616
Router/
Modem
AC Input
DSC Keypad
LCD4501
PK55XX
Notes:
- All wiring connections shall be run in a mechanically
protective conduit.
- Phone 1 program for T-Link ([301] set as DCAA).
- Phone 3 program in [303] and set as back-up to Phone 1
([380] option 5 ON, 6 OFF).
- Phone 2 program in [302] the same as Phone 3.
- T-Link supervision enabled (Section [851], option [023]
set to 01).
- Phone Line Monitoring (TLM) shall be enabled.
- PGM1 programmed as System Trouble (Section [009]
Program as type 09; Section [501] TLM option 3 ON).
- T-Link TL250 Zone 1 program as type 21 in Section [036]
and use reporting code 99 in section [050].
- 24h Test Transmission over phone line 1 and 2 must be
enabled (Section [376] set options 1 and 2 ON).
- Fire Alarms shall be sent over both channels (section
[351] set options 1 and 2 to ON).
- Dry contact outputs from ULC Listed Fire Alarm Control
Unit shall be connected to Zone inputs on the ULC Listed
DSC Subscribers’ Unit Fire.
4. Fire Alarm Control Unit (with no dialer) and IP Transmitter (Active Communication System)
Fire Alarm
Control Unit
AUX Power
12V/275mA
IP Transmitter
T-Link TL250
Router/
Modem
Internet/
Intranet
Zone Input
Outputs
Fire
Supervisory
Trouble
Keybus
Zone
Inputs
PGM
Output
RM1C ULC
Relay
8 Zone Expander
AC Input
(Optional)
DG009381
PC5108
PC5003C cabinet
Notes:
- Power for T-Link TL250 shall be provided from Fire
Alarm Control Unit or separately listed Power Supply
rated for the application (12V/275mA).
- All wiring connections shall be run in a mechanically
protective conduit.
- T-Link TL250 Supervision at Signal Receiving Centre
(SRC) shall be enabled (180 Sec.).
- For local supervision of the IP communicator connect
PGM output from T-Link TL250 to one zone input on
the Fire Alarm Control Unit.
- Dry contact outputs from ULC Listed Fire Alarm
Control Unit shall be connected to Zone inputs on the
T-Link TL250 (or PC5108 if used).
5. Fire Alarm Control Unit (with dialer) and IP Transmitter (Active Communication System)
Fire Alarm
Control Unit
AUX Power
12V/275mA
IP Transmitter
T-Link TL300
TIP/RING
TIP/RING
Zone Input
Zone
Input
Output
Trouble
PGM
Outputs
RM1C ULC
Relay
DG009382
PC5003C cabinet
Router/
Modem
Internet/
Intranet
Notes:
- Power for T-Link TL300 shall be provided from Fire
Alarm Control Unit or separately listed Power Supply
rated for the application (12V/275mA).
- All wiring connections shall be run in a mechanically
protective conduit.
- T-Link TL250 Supervision at Signal Receiving Centre
(SRC) shall be enabled (180 Sec.).
- For local supervision of the IP communicator connect
PGM output from T-Link TL300 to one zone input on
the Fire Alarm Control Unit.
- Dry contact Trouble output from ULC Listed Fire
Alarm Control Unit shall be connected to Zone input
on the T-Link TL300 for supervision of Tip/Ring
connection.
AC Input
6. Fire Alarm Control Unit (with dialer) and GSM Transmitter (Passive Communication System)
Fire Alarm
Control Unit
TIP/RING
AUX Power
12V/700mA
GSM Transmitter
GS3055-I
GS3060
3G3070
T1/R1
TIP/RING
GSM Network
(GPRS (IP Data) or Voice Channel)
PSTN
Zone Input
Outputs
Fire
Trouble
Zone
Inputs
PGM4
Output
RM1C ULC
Relay
GS3055-I/GS3060/3G3070
Cabinet
DG009753
AC Input
Notes:
- Power for GS3055-I/GS3060/3G3070 shall be provided from
Fire Alarm Control Unit or separately listed Power Supply
rated for the application (12V/700mA).
(Jumper JP3 shall be ON for Fire Monitoring)
- All wiring connections shall be run in a mechanically
protective conduit.
- For local supervision of the GSM transmitter connect PGM
output from GS3055-I/GS3060/3G3070 to one zone input on
the Fire Alarm Control Unit.
- Dry contact Trouble output from ULC Listed Fire Alarm
Control Unit shall be connected to Zone input on the
GS3055-I/GS3060/3G3070 for supervision of Tip/Ring
connection.
- Fire Alarms shall be sent over both communication channels.
Fire output from Fire Alarm Control Unit shall be connected to
the Input 1 on the GS3055-I/ GS3060/3G3070.
- 24h Test Transmission must be enabled on the dialer and on
the GS3055-I/GS3060/3G3070.
7A. DSC Subscribers' Unit Fire and GSM Transmitter (Passive Communication System)
AUX Power
12V/700mA
DSC
Subscribers’
Unit Fire
Fire Alarm
Control Unit
Outputs
Fire
Supervisory
Trouble
Zone
Inputs
PC4020
PC1864
PC1832
PC1616
GSM Network
(GPRS (IP Data) or Voice Channel)
GSM
Transmitter
GS3055-I
GS3060
3G3070
TIP
RING
PSTN
T1/R1
TIP/RING
HS2128
HS2064
HS2032
HS2016
Zone
Input
PGM4
PGM1
RM1C ULC
Relay
RM1C ULC
Relay
PC5003C
PC4050CR
cabinet
AC Input
GS3055-I/GS3060/
3G3070 cabinet
AC Input
DSC Keypad
DG009803
LCD4501
PK55XX
HS2LCD/ICN/LED
Notes:
- Power for GS3055-I/GS3060/3G3070 shall be provided from
Fire Alarm Control Unit or separately listed Power Supply
rated for the application (12V/700mA) (Jumper JP3 shall be
ON for Fire Monitoring).
- All wiring connections shall be run in a mechanically protective
conduit.
- Phone Line Monitoring (TLM) shall be enabled.
- Connect PGM4 output from GS3055-I/GS3060/3G3070
(Trouble conditions) to a zone input on the Subscriber Unit for
supervision of the GSM Transmitter.
- 24h Test Transmission over phone line (PSTN) and GS3055I/GS3060/3G3070 must be enabled.
- Fire Alarms shall be sent over both communication channels.
- On the Subscribers’ Unit program PGM1 for
PC1864/PC1832/PC1616 as System Event (Section [009] as
type 10; Section [501] Fire Event option 2 ON). An alternate
option is to program PGM1 as Zone Follower (Sec [009] = 29)
and assign Fire Zone to PGM1 in Section [551]. Ensure Bit 3
is on in [501]. In this case, a restored fire alarm condition does
not require the DSC control panel to be reset. For PC4020
program PGM1 as type [49] Steady Fire ([00070049].
- Dry contact outputs from ULC Listed Fire Alarm Control Unit
shall be connected to Zone inputs on the ULC Listed DSC
Subscribers’ Unit Fire.
- For ULC-S561 installations when using the PC5003C
enclosure it is required to install the listed hardwired
transformer outside the enclosure.
- The control panel manual shall be consulted for the list of
compatible keypads.
- Refer to detailed diagrams in Figure 8.
7B. DSC Subscribers' Unit Fire and GSM Transmitter Mounted Remotely
Alternate Wiring Diagram for DSC Subscribers’ Unit Fire and GSM Transmitter
Passive Communication System -Using Phone Line Supervision Relay
Fire Alarm
Control Unit
Outputs
Fire
Supervisory
Trouble
AUX Power
12V/700mA
DSC
Subscribers’
Unit Fire
Zone
Inputs
PC4020
PC1864
PC1832
PC1616
GS3055-I
GS3060
3G3070
T1/R1
TIP/RING
TIP
RING
Zone
Input
HS2128
HS2064
HS2032 PGM1
HS2016
RM1C ULC
Relay
PC5003C
PC4050CR
Cabinet
AC Input
AC Input
DSC Keypad
DG009804
LCD4501
PK55XX
HS2LCD/ICN/LED
GSM
Transmitter
GSM Network
GPRS
(IP Data)
PSTN
PGM1
PGM4
RM1C ULC
Relay
RM1C ULC
Relay
GS3055-I/GS3060/3G3070
Cabinet
Notes:
- Connect PGM output from GS3060/3G3070 (Phone Line Trouble) to a
zone input on the subscriber unit for supervision of the PSTN phone line
voltage.
- When the GS3060/3G3070 is installed remotely from the DSC Control
Panel, it is required to monitor the Phone Line Trouble condition at the
keypad by using an additional RM1C Relay.
- All wiring connections shall be run in a mechanically protective conduit.
- Refer to notes in Figure 7A and detailed diagrams in Figure 9 for
additional information.
8. Connection Details for GSM Supervision Relay and Redundant Fire Alarm Transmission
1
2 LE 3 4LI 5
3 4T1 5R1
1 TIP
2 RNG
GS3060/3G3070
6 O1
7 O2
8 O3
9 O4+OC
10 11 12 AS13 14 15 L116L217L3 18
L4 1912V20
COM6 PGM1
PGM2
PGM3
PGM4
AUX+
TAMPER
COM
Z1
Z2
Z3
Z4
DC 20
IN 7 8 9 10 11
12 13
14 15 16 17 18+19
GSM
Supervision
Relay
5.6 KOhm
Redundant
Fire Alarm
Initiation
PC1864
PC1832
PC1864
HS2128
PC1832
HS2064
Only
HS2032
Only
PC1864
PC1864
HS2128
Only
HS2064
Only
AUX+
BELL+
PGM1
PGM3
AUXBELL- RED BLK YEL GRN
PGM2
PGM4 Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
Z7 COM Z8 EGND
RING
TIP
R-1
T-1
DG009805
AC AC
NOTE: Use EOL resistor in series with N.O. contacts of the relay connected to PGM4
p
1
2 LE 3
TIP
3
1 2 RNG
4LI 5
T1
4 5R1
y
GS3060/3G3070
6 O1
7 O2
8 O3
9 O4+OC
10 11 12 AS13 14 15 L116L217L3 18
L4 1912V20
COM6 PGM1
PGM2
PGM3
PGM4
AUX+
TAMPER
COM
Z1
Z2
Z3
Z4
DC 20
IN 7 8 9 10 11
12 13
14 15 16 17 18+19
Redundant
Fire Alarm
Initiation
GSM
Supervision
Relay
5.6 KOhm
PC1864
PC1832
PC1864
HS2128
PC1832
HS2064
HS2032
Only
Only
PC1864
PC1864
HS2128
Only
HS2064
Only
AUX+
BELL+
PGM1
PGM3
AUXBELL- RED BLK YEL GRN
PGM2
PGM4 Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
Z7 COM Z8 EGND
RING
TIP
R-1
T-1
DG009806
AC AC
NOTE: Use EOL resistor in parallel with N.C. contacts of the relay connected to PGM4
9. Connection Details for GSM Supervision Relay, Phone Line Supervision and Redundant Fire Alarm Transmission
1
2 LE 3
3
2 RNG
1 TIP
4LI 5
4T1 5R1
GS3060/3G3070
6 O1
7 O2
8 O3
9 O4+OC
10 11 12 AS13 14 15 L116L217L3 18
L4 1912V20
TAMPER
COM
Z1
Z2
Z3
Z4
COM6 PGM1
PGM2
PGM3
PGM4
AUX+
DC 20
IN 7 8 9 10 11
12 13
14 15 16 17 18+19
Redundant
Fire Alarm
Initiation
5.6 KOhm
GSM
Supervision
Relay
5.6 KOhm
Phone Line
Supervision
Relay
PC1864
PC1832
PC1864
HS2128
PC1832
HS2064
HS2032
Only
Only
PC1864
PC1864
HS2128
Only
HS2064
Only
AUX+
BELL+
PGM1
PGM3
AUXBELL- RED BLK YEL GRN
PGM2
PGM4 Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
Z7 COM Z8 EGND
RING
TIP
R-1
T-1
DG009807
AC AC
NOTE: Use EOL resistor in series with N.O. contacts of the relay connected to PGM4
1
2 LE 3
TIP
3
1 2 RNG
4LI 5
T1
4 5R1
GS3060/3G3070
6 O1
7 O2
8 O3
9 O4+OC
10 11 12 AS13 14 15 L116L217L3 18
L4 1912V20
TAMPER
COM
Z1
Z2
Z3
Z4
COM6 PGM1
PGM2
PGM3
PGM4
AUX+
DC 20
IN 7 8 9 10 11
12 13
14 15 16 17 18+19
GSM
Supervision
Relay
Phone Line
Supervision
Relay
5.6
KOhm
5.6
KOhm
PC1864
PC1832
PC1864
HS2128
PC1832
HS2064
HS2032
Only
Only
PC1864
PC1864
HS2128
Only
HS2064
Only
AUX+
BELL+
PGM1
PGM3
AUXBELL- RED BLK YEL GRN
PGM2
PGM4 Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
Z7 COM Z8 EGND
RING
TIP
R-1
T-1
DG009808
AC AC
Redundant
Fire Alarm
Initiation
NOTE: Use EOL resistor in parallel with N.C. contacts of the relay connected to PGM4
10. TL260/TL260GS/GS2060/TL2603G/TL2603GR/3G2060/3G2060R Wiring Diagram Active/Passive Communication System
To external
antenna
Radio
AUDIO/DEFAULT
UA557
DSC
SIM Card
Holder
PWR PWR GND GND
PC-LINK
1
TL260/TL260GS/GS2060/
TL2603G/TL2603GR/
3G2060/3G2060R
Status
LEDs
GND SHLD
PC1616/1832/1864
UA503
NOTE: For more details, refer to the
control, panel Installation Manual p/n
29007916.
CON 4
1
PC-LINK
See PC-Link wiring
instructions below
AC AC
AUX+
BELL+
PGM1
PGM3
AUXBELL- RED BLK YEL GRN
PGM2
PGM4 Z1 COM Z2
Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 EGND
RING
TIP
R-1
T-1
Network Connection
(Available only for model
TL260/TL260GS/TL260/TL260R)
Use only CAT5 cable
(300ft/100m max.) Supervised
Input Ratings (from Bell Out)
11.1V - 12.6 VDC
100mA standby
400mA Alarm
DSC Panel minimum
power requirements
16 VAC 40 VA transformer
12 VDC 7Ah battery
+
DG009810
-
Notes:
- Power for TL260/TL260GS/GS2060/TL2603G/TL2603GR/3G2060/3G2060R/TL260/TL260R shall be provided from
PC1864/PC1832/PC1616 Subscriber’s unit (Bell+ and AUX-).
- Connect PC-Link cable between TL260/TL260GS/GS2060/TL2603G/TL2603GR/3G2060/3G2060R/TL260/TL260R and
PC1864/PC1832/PC1616 as instructed and enable T-Link interface (section [382] bit 5 ON).
- Use for communication SIA format, program Section [350]= 04, Section [165] = 001 and Section [167]=060.
- TL260/TL260GS/GS2060/TL2603G/TL2603GR/3G2060/3G2060R/TL260/TL260R can be used as a passive communication module
(back-up mode for Dialer) or as an active communication module (IP, GSM or both).
- For passive configurations:
· Phone line monitoring (TLM) shall be enabled on the panel (section [015] bit 7 ON).
· Program the analog phone number in Section [301] (primary path).
· Program “DCAA” in Section [302] (redundant path for Fire Alarms) and program Section [351] bit 1 and 2 ON.
· Program “DCAA” in Section [303] (back-up path).
· Program the call directions for tamper [359], opening/closing [367], maintenance [375] and test transmissions [376] as required by the
application (bit 1 and 5 ON).
· Complete programming of the TL260/TL260GS/GS2060/TL2603G/TL2603GR/3G2060/3G2060R/TL260/TL260R module in section [851]
(IP/GSM address, supervision options, IP/GSM test transmission time and cycle).
· For 24hr test transmission, [851] system test options [026-029] shall be enabled [FF] for the communication paths available. [851][124125] and [224-225] shall be programmed with time of day for test transmission and 1440 minutes (24h) for test transmission cycle.
- For active configurations:
· Phone line use is optional (depends on the IP or GSM channel being used and back-up power provisions for the IP channel). TLM does
not need to be programmed if the phone line is not used.
· Program “DCAA” in location [301] (IP/GSM module primary path). Select in section [851][005] whether the IP or GSM will be the primary
or secondary path.
· Complete programming of the TL260/TL260GS/GS2060/TL2603G/TL2603GR/3G2060/3G2060R/TL260/TL260R module in section [851]
(IP/GSM address, supervision options, IP/GSM test transmission time and cycle).
· Program heartbeat interval in Section [851][004]=005A (90s). The supervision window at the Signal Receiving Centre’s receiver shall be
programmed as max. 180s.
11.TL280/TL280R/TL2803G/TL2803GR/3G2080/3G2080R Wiring diagram Active/Passive Communication System
To external antenna
1
L SIM
o
c
k
AUDIO/DEFAULT
Jumper pins 4 and 5
to reset.
3G Radio
DSC
UA621
From NID
Red
Red
EGND
AUX BELL +
BELL RED
BLK
YEL
GRN
RJ-45
PC-LINK_2
NOTE: For more details, refer to the control
panel Installation Manual p/n 29008362.
DG009809
COM
YELLOW
SHLD
RXGND
TX+
TXRX+
PC-LINK
HS2128/2064/2032/2016
Network Link
TL2803G(R)
3G2080(R)
UA601
TL2803G(R)
Use only CAT5
Supervised
22AWG
Maximum cable length
100 m (328 ft)
Note: Communicator can be also
installed remotely in its own separate
cabinet along with power supply module
HSM2204/HSM2300. When using this
configuration, the module PCL-422
PGM1
PGM3
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8
(PC-link expander) shall be used. Refer
RING TIP T-1 R-1
AC AC AUX+
PGM2
PGM4
to PCL-422 Installation Instructions P/N
29008859.
Notes:
- Connect PC-link cable between TL280/TL280R/TL2803G/TL2803GR/3G2080/3G2080R and HS2128/HS2064/HS2032/HS2016 as instructed and enable the alternate communicator (section
[382] bit 5 ON).
- For communication format, program section [350] [001-004] (03 for Contact ID, 04 for SIA).
- TL280/TL280R/TL2803G/TL2803GR/3G2080/3G2080R can be used as either a passive or active communication module (Ethernet/Cellular or both)
- For passive configurations (Commercial Burg Line Security Level P2, Backup transmission configuration):
• Phone line monitoring (TLM) shall be enabled on the panel (section [015] bit 7 ON).
• Set communicator path on the panel: section [300] [001] set to Phone line, [002] set to Alt Comm Rec 1(Ethernet channel) or Alt Comm Rec 3(Cellular channel). Note that any communicator
path can be selected as primary (location [001] or backup (location [002] in this configuration. Enable Cellular Low Signal Trouble in section [851][005] bit 8 ON.
• Program the analog phone number in Section [301] [001] (primary path).
• Program the partition call directions in Section [311] (enable both receivers in subsection [001] for alarms, [002] for tamper, [003] for opening/closing) as required by the application.
• Program system call directions in Section [309] (enable both receivers in subsection [001] for maintenance, [002] for test transmission) as required by the application.
• Select backup option in Section [384](will select path to backup primary path).
• Complete programming of the TL280/TL280R/TL2803G/TL2803GR/3G2080/3G2080R module in section [851] (Ethernet/Cellular address, supervision options, Ethernet/Cellular test
transmission time and cycle).
- For passive configurations (Fire Monitoring or Commercial Burglary Line Security Level P3, simultaneous transmission configuration):
• Phone line monitoring (TLM) shall be enabled on the panel (section [015] bit 7 ON).
• Set communicator paths on the panel: section [300][001] set to Phone line, [002] set to Alt Comm Auto. Enable Cellular Low Signal Trouble in section [851][005] bit 8 ON. Note that any
communicator path can be selected as primary (location [001]), secondary (location [002]) or third (location [003]) in this configuration, since all paths transmit the selected events (see
sections [309] and [311] -parallel communication.
• Program the analog phone number in Section [301] [001].
• Program the partition call directions in Section [311] (enable all three receivers in subsection [001] for alarms, [002] for tamper, [003] for opening/closing) as required by the application.
• Program system call directions in Section [309] (enable all three receivers in subsection [001] for maintenance, [002] for test transmission) as required by the application
• Enable parallel transmission in Section [380] bit 5 ON. Important Note: Enabling this option ensures the selected events are transmitted in parallel on all enabled communication paths.
• Complete programming of the TL280/TL280R/TL2803G/TL2803GR/3G2080/3G2080R module in section [851] (Ethernet/Cellular address, supervision options, Ethernet/Cellular test
transmission time and cycle).
• For 24hr test transmission, [851] system test options [026-029] shall be enabled [FF] for the communication paths available. [851][124-125] and [224-225] shall be programmed with time of
day for test transmission and 1440 minutes (24h) for test transmission cycle.
- For active configurations (Fire Monitoring, Commercial Burglary Security Level A1-A4):
• Phone line use is optional (depends on the Ethernet or Cellular channel being used and back-up power provisions for the Ethernet channel). TLM does not need to be programmed if the
phone line is not used. Enable Cellular Low Signal Trouble in section [851][005] bit 8 ON.
• Set communication path: in Section [300][001] select 01 for Alt Comm. Rec 1 (Ethernet channel), or 02 for Alt Comm. Rec 3(Cellular channel).
• Complete programming of the TL280/TL280R/TL2803G/TL2803GR/3G2080/3G2080R module in section [851] (Ethernet/Cellular address, supervision options, Ethernet/Cellular test
transmission time and cycle).
• Program heartbeat interval in Section [851][004]=005A (90s). The supervision window at the Signal Receiving Centre’s receiver shall be programmed as max. 180s. Note: select the proper
supervision profile from C24 website when enrolling/registering the Cellular alarm communicator for first time.
The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco International Ltd. will aggressively enforce its intellectual property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by
Tyco International Ltd. are the property of their respective owners, and are used with permission or allowed under applicable laws.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your
sales representative.
©2013 Tyco International Ltd. and its Respective Companies.
All Rights Reserved. • www.dsc.com • Printed in Canada