CHICAGO 66506 Electric Drain Cleaner Set Up and Operating Instructions
The CHICAGO 66506 Electric Drain Cleaner is a powerful tool for clearing clogged drains. It features a 50-foot long cable that can reach deep into pipes, and a variety of cutters to tackle different types of blockages. The unit also has a built-in GFCI for added safety.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
ElEctric Drain clEanEr
66506
SEt up anD OpErating inStructiOnS
Distributed exclusively by Harbor Freight tools ® .
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our website at: http://www.harborfreight.com
read this material before using this product.
Failure to do so can result in serious injury.
SaVE tHiS manual.
Copyright © 2002 by Harbor Freight Tools ® . All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of
Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.
For technical questions or replacement parts, please call 1-800-444-3353.
SpEciFicatiOnS
Electrical Requirements 120 V~, 60 Hz, 1/3 HP; 4.7 No Load Amps
Power Switch Steel Toggle Switch
Normal – Off - Unbind
Overall Dimensions
Drum Dimensions
Drain Pipe Capacity
Cutter Accessories
Construction
Cable Size/Length
Weight
20” L x 14” W x 20-1/2” H
13” Diameter x 8” Wide
1-1/4” to 4” Diameter
Arrow Head, Boring Gimlet,
1-1/2” U-Cutter, 1-1/4” Side Cutter Blade
1” & 1-1/4” Square Steel Tubing
3/16” Thick Steel Plate; Rubber & PVC
1/2” Diameter x 50’ Long
70.2 Pounds
note: Due to the environment this tool is used in, it must be powered by a 3 prong grounded
GFCI (Ground Fault Circuit Interrupter) protected circuit or outlet.
SaVE tHiS manual
You will need this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram.
Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Write the product’s serial number in the back of the manual near the assembly diagram, or write month and year of purchase if product has no number. Keep this manual and invoice in a safe and dry place for future reference.
1.
2.
3.
4.
5.
6.
SaFEtY WarningS anD prEcautiOnS
KEEp WOrK arEa clEan anD DrY. Cluttered, damp or wet work areas invite injuries.
KEEp cHilDrEn aWaY FrOm WOrK arEa. this product.
Do not allow children to handle
StOrE iDlE EQuipmEnt. When not in use, tools and equipment should be stored in a dry location to inhibit rust. Always lock up tools and equipment and keep out of reach of children.
DO nOt uSE tHiS prODuct iF unDEr tHE inFluEncE OF alcOHOl Or
DrugS. Read warning labels on prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any doubt, do not attempt to use this product.
inDuStrial applicatiOnS muSt FOllOW OSHa rEQuirEmEntS.
DO nOt OVErrEacH. Keep proper footing and balance at all times to prevent tripping, falling, back injury, etcetera.
SKU 66506 For technical questions, please call 1-800-444-3353.
REV 09c, 09g
Page 2
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
StaY alErt. Watch what you are doing at all times. Use common sense. Do not use this product when you are tired or distracted from the job at hand.
cHEcK FOr DamagED partS. Before using this product, carefully check that it will operate properly and perform its intended function. Check for damaged parts and any other conditions that may affect the operation of this product. Replace or repair damaged or worn parts immediately.
rEplacEmEnt partS anD accESSOriES. When servicing, use only identical replacement parts. Only use accessories intended for use with this product.
Approved accessories are available from Harbor Freight Tools.
maintain tHiS prODuct WitH carE. Keep this tool clean and dry for better performance. For your safety, service and maintenance should be performed regularly by a qualified technician.
uSE tHE rigHt prODuct FOr tHE rigHt JOB. There are certain applications for which this product was designed. Do not use small equipment, tools or attachments to do the work of larger industrial equipment, tools or attachments. Do not use this product for a purpose for which it was not intended.
guarD againSt ElEctric SHOcK. Do not submerge the Motor Housing (8) in water or other liquids. Always prevent body contact with grounded surfaces such as pipes, radiators, ranges, refrigerators, etcetera.
Do not operate the Electric Drain Cleaner if the operator or machine is standing in water. To comply with the National Electric Code (NFPA70), and to provide additional protection from the risk of electrical shock, the Electric Drain Cleaner must only be connected to a receptacle that is protected by a Ground Fault Circuit Interrupter
(GFCI).
pEOplE WitH pacEmaKErS SHOulD cOnSult tHEir pHYSician(S) BE-
FOrE uSE. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
rEDucE tHE riSK OF FirE anD/Or EXplOSiOn. Sparks inside the Motor assembly can ignite flammable vapors, liquids, and dust. Do not use the Electric Drain
Cleaner in the presence of any flammable, combustible, or explosive substances.
prEVEnt tHE caBlE FrOm WHipping BY placing tHE Drain clEanEr aS clOSE tO tHE Drain linE aS pOSSiBlE (a maXimum OF 2 FEEt OF caBlE SHOulD BE EXpOSED).
DO nOt uSE tHE ElEctric Drain clEanEr in a linE cOntaining cHEmi-
cal Drain clEanErS. Exposure to these chemicals can cause injury to the operator and/or damage the machine.
DrESS SaFElY. Nonskid footwear or safety shoes should be used when working with this product. Do not wear loose clothing or jewelry as they can become caught in moving parts. Wear a protective hair covering to prevent long hair from
SKU 66506 For technical questions, please call 1-800-444-3353. Page 3
18.
19.
20.
21.
22.
23. becoming caught in moving parts. If wearing a long-sleeve shirt, roll sleeves up above elbows.
uSE EYE, HanD, anD BrEatHing prOtEctiOn. Wear ANSI-approved splashresistant safety goggles, NIOSH-approved dust mask/respirator, and heavy-duty
LEATHER gloves during use. Use care near the sharp edges of the drum.
uSE HEaVY-DutY lEatHEr glOVES OnlY. Cloth gloves can become caught between the rotating coils of the Cable (37), resulting in loss of fingers.
this product contains or produces a chemical known to the State of california to cause cancer and birth defects (or other reproductive harm).
(California Health & Safety Code § 25249.5, et seq.)
DO nOt uSE anY EXtEnSiOn cOrD On tHiS itEm.
guarD againSt caBlE BrEaKagE. Before each use, check the cable for kinks or any damage. Never use a damaged cable. Protect the cable from rust by maintaining and lubricating it in accord with the maintenance section and chart near the end of the manual.
aVOiD Drain linE DamagE. Some city drain line systems may have pipes that are too fragile for this machine. If you are going to probe into unfamiliar plumbing with this machine, first stop and contact your sewer line authority or a local plumber for advice.
tHE WarningS anD prEcautiOnS DiScuSSED in tHiS manual cannOt cOVEr all pOSSiBlE cOnDitiOnS anD SituatiOnS tHat maY Occur.
The operator must understand that common sense and caution are factors that cannot be built into this product, but must be supplied by the operator.
unpacKing
When unpacking, check to make sure all parts shown on page 8 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible.
SKU 66506 For technical questions, please call 1-800-444-3353. Page 4
SEt up
note: For additional references to the parts listed below, refer to the Parts List and Assembly Diagram near the end of this manual.
Select and attach the proper cutter tool
cutter tool
Arrow Head (38)
Boring Gimlet (39)
1-1/2” U-Cutter (40)
1-1/4” Side Cutter Blade (41) application
Starting tool for cutting and scraping
Starting tool to pierce clogs
Finishing tool for grease stoppages
Starting tool to remove loose objects
note: Insert the desired Cutter Tool (38, 39, 40, 41) in the female connector located at the end of the Cable (37). Secure the Cutter Tool to the Cable with Round Head Bolt
(61) and Spring Washer (36).
note: Start with the Arrow Head (38) or Boring Gimlet (39) Cutter Tool. Once the drainpipe is opened, follow with the 1-1/2” U-Cutter (40) or 1-1/4” Side Cutter Blade (41) which scrape the inside edge of the drainpipe, ensuring more thorough cleaning.
OpEratiOn
caution: Make sure you are fully prepared to start the drain cleaning process prior to plugging the Electric Drain Cleaner into an electrical outlet and are observing all safety warnings.
note: It is critical that before changing from UNBIND to NORMAL mode, or NORMAL to
UNBIND mode, that you release Foot Switch (13A); and allow the drum cable to completely stop.
note: Wear heavy-duty leather work gloves, ANSI-approved safety goggles, and NIOSH-approved dust mask/respirator before set up or use
1. When ready, plug the GFCI Power Cord & Plug (14) into a properly grounded 120
V~ receptacle. Check the GFCI unit before use as follows: a. b.
The GFCI indicator should be off.
Press the RESET button: indicator should turn on.
c. d.
Press the TEST button: indicator should turn off.
If indicator responds as described, then press RESET button for use.
DO nOt uSE iF gFci tESt FailS.
2. Position the Electric Drain Cleaner within two feet of the drain opening. if the machine cannot be positioned within two feet of the drain opening, run the cable (37) through an appropriate size pipe or guide tube (not included) to prevent the cable from whipping.
REV 09g
SKU 66506 For technical questions, please call 1-800-444-3353. Page 5
4.
5.
3.
6.
7.
Pull the Cable (37) by hand, with its attached Cutter Tool (38, 39, 40, 41) out from the Center Hub (34). Attach the appropriate cutter tool and insert the Cable and
Cutter Tool into the drainpipe. caution: Do not switch on the motor while inserting the cable into drainpipe.
Prior to stepping on the Foot Switch (13A), make sure the Motor Direction Switch
(11) is set in the Normal position.
Keep both hands on the Cable at all times, while guiding it with a firm even pressure into the drain pipe. Then press the Foot Switch (13A) to start Drum/Cable rotation.
When the cutter hits an obtacle/blockage, press the Foot Switch (13A) to rotate the cable permiting the cutter to pass on.
If possible, keep a small steady stream of water running into the drain to help lubricate the cutter and wash debris down the drain.
Warning! Do not allow water to accumulate in the work area. Water accumulation increases the risk of electric shock or slipping, in addition to
causing property damage. Drop cloths, GFCI-protected wet vacuum cleaners, basins, or other methods (none included) may be used to help contain and dispose of water. A certain amount of water will almost always be present when cleaning a drain.
If an obstruction is reached that the cutter does not immediately bore through (could even be a sharp bend in pipes): a. Turn Motor Switch (11) (see photo’s on next page) to two and pull the cable back about a foot or two.
Unbind for a second or b. c. d. e.
Switch Motor Switch to Normal and gently press cable back towards the obstruction again for a few seconds. Do not allow excess torque to build up in the cable, otherwise the cable may break. nOtE: If the motor gets too hot the overload switch may turn off the motor. Allow the motor to cool down then restart the motor.
Continue steps a. and b. until the clog is cleared.
Larger clogs may require that you periodically bring the cable back to the pipe opening in Normal rotation, shut off the machine and unplug it, allow cable to stop spinning, and remove debris from the cutter head before proceeding.
Cutting heads may need to be changed after penetration to clean out the clog, see instructions on page 5.
SKU 66506 For technical questions, please call 1-800-444-3353. Page 6
8.
9.
10.
Figure 1
Use the Unbind position on the Motor Direction Switch (11) when having difficulty getting the Cable (37) around tight bends or if the user sees excess torque buildup on the cable. Stop the Drain Cleaner immediately and put it in Unbind for a few rotations to relieve the tension. Do not use the unbind position for more than a few seconds at a time, as it could cause tangling in the Drum (31) or kinking.
caution: When switching the Motor Switch from Normal to Unbind position and vise versa, the Motor Switch must be first switched to OFF position and the Motor must stop running.
After pipe is cleared, release Foot Switch and switch Motor Switch to OFF position to stop rotation and blush the drain and cable with water. Then push Cable (37) slowly by hand back into Drum
(31) completely except the cutter head. Unplug the Electric Drain Cleaner from its electrical supply source. nOtE: If needed, rotate the Drum by hand (in direction shown in photo, see arrow) while pushing Cable back into Drum.
Figure 2
Remove and clean the cutter(s) used and store them in the Toolbox (50). Feed the remaining cable into the drum. Clean, dry, and lubricate the Drain Cleaner and
Cable before storage according to the directions in the Inspection, Maintenance, and Cleaning section.
SKU 66506 For technical questions, please call 1-800-444-3353.
REV 09g
Page 7
inSpEctiOn, maintEnancE, anD clEaning
caution: Always disconnect the Electric Drain Cleaner from its electrical supply source before performing any inspection, maintenance, or cleaning.
note: Wear heavy-duty leather work gloves, ANSI-approved safety goggles, and NIOSHapproved dust mask/respirator before maintenance. Use caution near the sharp edges of the drum.
1.
2.
Before each use, inspect the general condition of the Drain cleaner:
Check for broken parts, damaged power cord, cable, and any other condition that may affect its safe operation. If a problem with the Electric Drain Cleaner occurs, immediately discontinue using the tool and have the problem corrected before further use.
Do not use damaged equipment.
after each use, clean and lubricate the unit: a. Remove and clean the cutter(s) used and store them in the Toolbox (50).
b. Pour water out of the Drum (31). Clean the outside of the unit and the cable with a damp cloth and a solution of one part chlorine bleach to twenty parts water.
Do not use solvents to clean the Electric Drain Cleaner, as damage to the tool may occur. Then, dry completely.
c. d.
Always keep the Cable (37) well oiled by pouring a light weight oil directly into the Drum (31). Then, turn on the Electric Drain Cleaner to rotate the Drum, lubricating the entire Cable. In addition, make sure all other moving parts are adequately lubricated to protect against sand and any other abrasive material.
When storing, keep the Electric Drain Cleaner inside a box or covered with a dry cloth cover in a dry location.
3. motor Belt pulley (16)
4.
5. positioning the V-Belt (21):
Make sure that the V-Belt rests properly into the groove on the Motor Belt Pulley (16) and sits on the Drum (31) properly, see illustration to the right.
Belt Tensioning: The V-Belt (21) tension is adjusted automatically by the Motor Seat Spring (6). This spring, which is located inside the tube, continuously pushes the Motor Seat (7) and Motor (8) up during operation.
It is unnecessary to adjust the belt tension manually.
thorough cable (37) inspection:
Lay out and inspect entire length of cable. Look for rust, kinks, unraveling, breaks, smooth spots, or other damage. If any damage is noted, the cable should be replaced.
Belt (21) cable (37) replacement: a. Unbolt and remove Cable Stop (65).
Figure 3
Drum (31)
SKU 66506 For technical questions, please call 1-800-444-3353. Page 8
6. d. e. f. b. Remove almost entire length of Cable (37) from Drum (31) until the connection from the short cable attached to the drum to the long Cable (37) is visible.
c. cautiOn! cable under tension.
Cable will suddenly spring out when released, use discretion when detaching.
Cautiously remove the Cable Connection
Screw (51) from the connection.
g. h. i. j.
Remove Cable from Cable Holder (32).
Verify that short drum cable is undamaged.
Insert the flat connecting end of new Cable into Cable Holder (32) until it comes out in the drum.
Figure 4 important! thread new cable into Drum at
least one full revolution before trying to connect it to drum cable. This will make connection much easier and safer.
Short Drum cable to long cable connection
Hold the ends of both cables together, insert the Cable Connection Screw (51) from the flat side of the connector, and tighten it in place.
Manually feed new cable into place in Drum (31). When there are about two full turns of cable still in the Drum, reattach Cable Stop (65) to inside of Drum.
Then lubricate new cable by pouring a light weight oil directly into the Drum
(31). Then, turn on the Electric Drain Cleaner to rotate the Drum, lubricating the entire Cable.
motor Seat Spring (6) inspection: a. Remove the belt from around the Drum. The motor should move upward. If it b. does not, then the Motor Seat Spring (6) needs replacement.
Press down on the motor. Some force should be required to make the motor move downward. If the motor moves downward easily, then the Motor Seat
Spring is too weak to properly tension the belt and should be replaced.
c. d.
The Motor Seat Spring is installed under pressure and therefore should be installed only by a qualified technician.
After inspection, install the Belt into place around the pulley and the Drum.
maintenance type
Inspect machine, including
Cable end, for damage (see #1, above)
Clean, dry, and lubricate, including oiling the Cable (37)
(see #2, above)
Check/adjust Belt (21) position
(see #3, above)
maintEnancE cHart
Before use after use monthly Every 6 months
X
X X
X
X
X
SKU 66506 For technical questions, please call 1-800-444-3353. Page 9
maintenance type
Check/replace Belt (21)
Check/replace entire Cable (37)
(see #4 & #5, above)
maintEnancE cHart
Before use after use monthly Every 6 months
X
problem
Motor will not start
Motor cuts off during use.
Cable binds, tangles, or kinks outside drum
1.
2.
3.
4.
5.
trOuBlESHOOting cHart
possible causes probable Solutions
Cord not connected.
No power at outlet.
Motor damaged.
GFCI unit on cord tripped.
Pneumatic Foot Switch (13A) is damaged or air line to Switch is kinked or leaking.
1.
2.
3.
4.
5.
Check that cord is plugged in.
Check power at outlet.
Repair/replace motor.
Reset GFCI unit.
Check Pneumatic Foot Switch and airline for kinks, leaks or holes.
Thermal Protection Switch may have tripped.
Turn Cleaner off, allow motor to cool, then restart. Warning! Stay clear of cable when turing cleaner back on.
release Foot Switch (13) and switch motor Direction Switch (11) to off immEDiatElY, then check the following:
1.
2.
3.
4.
5.
6.
Cable rotation wrong.
Cutter bound against clog or wall of pipe.
Cable not properly lubricated.
Pipe diameter too small.
Cable forced forward into drain.
Drain cleaner too far (more than 2’) from drain opening.
1.
2.
3.
Motor Direction Switch (11) must be set to normal direction, even when removing cable from pipe.
Release Foot Switch (13). Switch
Motor Direction Switch to unbind. press Foot Switch only for a
second or two, then resume normal rotation and operation.
Oil cable regularly according to
Maintenance instructions. Add extra oil if problems arise.
4.
5.
Pipe diameter must be from 2”–4”.
Feed cable gradually, allow it to work at its own pace.
6. Move drain cleaner closer or run cable through guide (not included).
Check condition of cable and cutter after binding or tangling. Do not use cable or cutter if damaged.
Cable tangles within drum, or drum coil collapses
1.
2.
Motor operating in unbind direction.
Cable being forced down drain.
1.
2.
Operate motor in normal rotation.
Feed cable gradually, allow it to work at its own pace.
Warning! The electrical components of this item should be repaired only by a qualified technician, especially since it is often used under wet circumstances. the power supply system and GFCI unit are only to be serviced by a certified electrician.
SKU 66506 troubleshooting chart continued on next page.
For technical questions, please call 1-800-444-3353. Page 10
troubleshooting chart continued from previous page.
problem
Foot switch does not properly control drum rotation
Motor turns, but drum does not turn
1.
2.
3.
4.
5.
trOuBlESHOOting cHart
possible causes
Defective foot switch.
Belt mounted incorrectly.
Belt excessively worn.
Motor Seat Spring (6) worn out or broken.
Drum Release Rod (25) not in place.
Safety Clutch (part of 16) slipping from excess force.
GFCI unit trips when Foot Switch is pressed
1.
2.
3.
4.
Cord or cleaner wet.
Motor Direction Switch defective.
Short circuit in motor.
Damaged power cord or GFCI unit.
Foot Switch Sticks Overloading of the motor.
1.
2.
3.
4.
5.
1.
2.
3.
4. probable Solutions
Have qualified technician repair or replace foot switch.
Check and correct Belt mounting, see maintenance.
Replace Belt.
Inspect and repair/replace Motor
Seat Spring.
Make sure that Drum is mounted properly with drum release rod in place, holding the shaft.
Do not force cable down pipe.
Keep cleaner and cord dry.
Repair or replace switch.
Repair or replace motor.
Electrician should repair or replace.
Press the foot switch several times.
Unbind/Reverse
Switch does not work
The centrifugal switch requires the motor to stop before changing direction.
Move the Unbind/Reverse switch to
“OFF” . Wait for the motor to stop completely before switching from
“Normal” to “Unbind” or visa versa.
Warning! The electrical components of this item should be repaired only by a qualified technician, especially since it is often used under wet circumstances. the power supply system and GFCI unit are only to be serviced by a certified electrician.
SKU 66506 For technical questions, please call 1-800-444-3353. rev 09b
Page 11
plEaSE rEaD tHE FOllOWing carEFullY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEM-
BLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER
OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER
THAT HE OR SHE IS qUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR
SHE IS qUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER
AND/OR DISTRIBUTOR ExPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS
SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE
BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS
TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR
HER INSTALLATION OF REPLACEMENT PARTS THERETO.
part Description
1 Main Frame
2 End Cup
3 Rubber Foot
4 Round Head Bolt (M6 x 20)
6 Motor Seat Spring
7 Motor Seat
8* Motor
9 Protection Shield
11* Motor Direction Switch
13A* Pneumatic Foot Switch
14* GFCI Power Cord & Plug
16 Motor Belt Pulley Wheel
17 Hex Bolt (M8 x 20)
18 Spring Washer
19 Hex Nut (M8)
20 Inner Hex Bolt (M6 x 13)
21 V-Belt (A-1118)
22 Position Sleeve
23 Drum Release Retaining Sleeve
24 Drum Release Spring
25 Drum Release Rod
26 Rear Hub
27 Retaining Ring
28 Shaft
29 Washer
30 Nylon Washer
31** Drum
32 Cable Holder
33 Nylon Washer
partS liSt
Q’ty
3
1
1
1
1
1
1
1
1
1
1
2
2
4
2
9
4
1
1
1
1
1
1
1
1
4
4
1
4 part Description Q’ty
34 Center Hub
35 Round Head Bolt (M6 x 15)
36 Spring Washer
37 Cable
38 Arrow Head
39 Boring Gimlet
40 U-Cutter (1-1/2”)
41 Side Cutter Blade (1-1/4”)
43 Flat Washer 8
45 Locking Nut (M8)
46 Sleeve Set Screw (M5 x 5)
47 Inner Hex Bolt (M8 x 8)
50 Tool Box 1
51 Cable Connecting Screw (M6 x 14) 1
52 Rear Cable Fixing Screw (M8 x 16)
53 Locking Nut M8
2
1
8
5
1
1
1
1
3
1
1
3
54 Small Motor Belt Pulley Wheel
55 Sleeve
56 Spring
57 Retaining Washer
59 Flat Washer 8
60 Rear Cable
61 Round Head Bolt (M6 x 18)
62 Rear Cable Rivet
64 Inner Hex Screw (M6 x 15)
65 Cable Stop
66 Inner Hex Screw
5
1
1
1
1
1
1
1
1
1
1
1
4
* All 4 parts only available as a Motor/Foot Switch Assembly, order part 42.
** Part 31, Drum, includes riveted on 5 foot cable.
SKU 66506 For technical questions, please call 1-800-444-3353. Page 12
aSSEmBlY Diagram
record product’s Serial number Here:
note: If product has no serial number, record month and year of purchase instead.
note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.
SKU 66506 For technical questions, please call 1-800-444-3353. Page 13
limitED 90 DaY WarrantY
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS ExPRESSLY IN LIEU OF ALL
OTHER WARRANTIES, ExPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353
SKU 66506 For technical questions, please call 1-800-444-3353. Page 14
advertisement
Key Features
- 50-foot cable
- Variety of cutters
- Built-in GFCI
- Powerful motor