eDVR User`s Guide

Add to my manuals
86 Pages

advertisement

eDVR User`s Guide | Manualzz

eDVR User’s Guide

DS412

(v 3.1)

FCC Compliance Statement

Caution : Any changes or modifications in construction of this device which are not expressly approved the party responsible for compliance could void the user's authority to operate the equipment.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help.

Warning

1. Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type.

2. Disposal of used batteries according to the general recommendations against the environmental pollution.

3. Do not throw the batteries into a fire, and do not heat, short-circuit or attempt to disassemble the batteries.

4. the battery in remote controller should not be recharged.

Important Notice

1. Do not place heavy objects on the top of the DS412.

2. DS412 is for indoor use. It is not weatherproof. Use DS412 with referring to its environmental specifications (Temperature & Humidity). To clean the DS412, gently wipe the outside with a clean dry cloth.

3. Be sure to use a DC adapter that is provided by Web Gate Inc. Connecting DS412 directly to an AC current will cause electric damages to DS412.

4. Be careful not to drop the DS412. Physical shocks may harm the product. In addition, be sure the

DS412 is secured after installation.

5. DS412 is made of metal. Therefore you can hurt human beings if you throw it to them or hit on them.

When installing DS412, be cautious to locate on safe places where children are unreachable.

6. If DS412 does not operate properly, please contact the closest WEBGATE distributor for after sales service. Tampering or disassembling the product will void the warranty.

7. Security surveillance laws may differ for each country. Therefore, please contact the local region first to avoid any surveillance law violations.

Contents

OVERIVEW ................................................................................................................................... 7

1. Introduction .......................................................................................................................... 7

2. Product description ............................................................................................................. 9

2.1. Front panel ...................................................................................................................... 9

2.2. Rear panel..................................................................................................................... 10

2.3. Installation summary ..................................................................................................... 11

Basic configuration................................................................................................................... 12

3. Monitoring........................................................................................................................... 12

3.1. Viewing basic screen .................................................................................................... 12

3.2. Viewing single full screen.............................................................................................. 12

3.3. Viewing multi screen ..................................................................................................... 12

3.4. Viewing all channels with sequence mode ................................................................... 13

3.5. Viewing an alarm triggered channel ............................................................................. 14

3.6. Viewing images with digital zoom ................................................................................. 14

3.7. Viewing with connected PTZ......................................................................................... 14

3.8. Using relay .................................................................................................................... 16

3.9. Using screen lock.......................................................................................................... 16

4. Playback.............................................................................................................................. 16

4.1. Playback via various mode ........................................................................................... 16

4.1.1. Playback via basic screen (full screen) ................................................................. 16

4.1.2. Playback via multi screen ...................................................................................... 17

4.1.3. Playback with digital zoom..................................................................................... 17

4.1.4. Various playback modes........................................................................................ 17

4.2. Using search mode ....................................................................................................... 18

4.3. Copy / Backup / Delete data manager.......................................................................... 19

4.3.1. Copy image............................................................................................................ 19

4.3.2. Backup manager.................................................................................................... 20

4.3.3. Delete data ............................................................................................................ 21

4

5. Configuration...................................................................................................................... 22

5.1. Quick setup ................................................................................................................... 22

5.1.1. Date/Time .............................................................................................................. 22

5.1.2. Recording .............................................................................................................. 25

5.2. Camera – analog camera channels (Ch 1 ~ Ch 4) ....................................................... 27

5.3. Recording – analog camera channels (Ch 1 ~ Ch 4)................................................. 30

5.3.1. Global setting......................................................................................................... 30

5.3.2. Each channel setting ............................................................................................. 31

5.4. Setting alarm recording................................................................................................. 35

5.4.1. Setting sensor........................................................................................................ 35

5.4.2. Setting motion detection ........................................................................................ 36

5.4.3. Setting text............................................................................................................. 39

5.4.4. Setting global alarm recording............................................................................... 41

5.4.5. Setting each channel ............................................................................................. 42

5.5. Alarm action. ................................................................................................................. 43

5.5.1. Schedule................................................................................................................ 43

5.5.2. Setup ..................................................................................................................... 44

5.6. Monitor .......................................................................................................................... 45

5.7. System .......................................................................................................................... 47

5.7.1. Audio...................................................................................................................... 47

5.7.2. Time schedule........................................................................................................ 48

5.7.3. Special time ........................................................................................................... 49

5.7.4. Security .................................................................................................................. 50

5.7.5. Disk setup .............................................................................................................. 51

5.7.6. Network.................................................................................................................. 52

5.7.7. Serial setup............................................................................................................ 58

5.7.8. Miscellaneous ........................................................................................................ 59

5.8. Utility ............................................................................................................................. 61

5.8.1. Disk manager......................................................................................................... 62

5.8.2. USB utility .............................................................................................................. 64

Advanced configuration ........................................................................................................... 66

6. Using IP cam....................................................................................................................... 66

6.1. Activating IP cam menu ................................................................................................ 66

5

6.2. Camera setting – IP camera channels (Ch 5 ~ Ch 16)................................................. 67

6.2.1. Configuration ......................................................................................................... 67

6.2.2. Local IP cam list..................................................................................................... 69

6.3. Recording – IP camera channels (Ch 5 ~ Ch 16) ......................................................... 70

6.4. Alarm rec. - IP cam channel (Ch 5 ~ Ch 16)................................................................. 71

6.5. IPCam sensor ............................................................................................................... 72

6.6. IPCam Relay................................................................................................................. 72

7. Connecting external device .............................................................................................. 73

7.1. Using text device........................................................................................................... 73

7.1.1. Setting at text menu............................................................................................... 73

7.1.2. Setting at serial setup’s RS232 menu ................................................................... 74

7.1.3. Setting at alarm rec. menu .................................................................................... 75

7.1.4. Setting at recording menu ..................................................................................... 76

7.2. Using keyboard ............................................................................................................. 77

7.2.1. Setting at serial setup’s RS232 menu ................................................................... 77

7.2.2. Setting at serial setup’s PTZ menu........................................................................ 77

APPENDIX ................................................................................................................................. 78

Appendix #1 Technical specification....................................................................................... 79

Appendix #2 Utilizing IP addresses on local network ........................................................... 82

#2.1 Introduction ...................................................................................................................... 82

#2.2 IP construction and network class ................................................................................... 82

#2.3 C-class network ............................................................................................................... 83

6

OVERIVEW

1. Introduction

What is DS412?

DS412 supports 4 analog video channels and 12 IP video channels simultaneously. Video, Audio, and

Text Event-Logs are digitized and stored on two internal hard-drives. Using a ‘Proprietary Wavelet

Algorithm,’ average file size is 1-5KB while still maintaining clarity high enough for facial-recognition.

In addition, Wavelet-compressed images are impossible to manipulate.

Due to our proprietary Wavelet Algorithm, the DS412 processes analog video into crisp, clear, and courtadmissible pictures that are up to 500% smaller than comparable JPEG images. With this efficiency,

DS412 records over 30 days on a 200GB hard disk drive when recording 4 channels at the speed of 10ips per channel. DS412 also allows users to record and playback audio for one channel.

Setting-up DS412 is as easy as setting up a VCR. DS412 starts to record as soon as power is supplied and

CCTV cameras are connected. DS412 offers an easy setup, as well as advanced menus. With ‘Quick

Setup’, DS412 can be setup and begin recording in as little as 5 minutes. The default settings offer quality and efficiency without the hassle of confusing menus.

Equipped with (3) IEEE 1394 ports (Fire-Wire) and (3) USB ports, DS412 can expand its recording capacity to up to 4TB easily. For easy backup, Windows (FAT32) formatted HDD is compatible with

DS412. Simply back up the desired data and connect the HDD to your PC to review critical images.

7

Key features

- Expandable up to 16 channels (4 analog video channels + 12 IP video channels)

- 1 channel audio recording & playback

- Recording, Playback, Back-up, Network recording, and Network playback at the same time

(Pentaplex)

- Total 120 ips recording speed (Analogue video 60ips + IP video 60ips)

- Total 120 ips display speed (Max 60ips over Network)

- Displaying live and recorded images on PC as well as CCTV Monitor

- Built-in hardware Quad Splitter for analog video

- Built-in software multiplexer for all 16 live monitoring channels

- (1 / 4 / 9 / 13 / 16Ch Mode on CCTV Monitor as well as PC)

- Maximum 4TB storage capacity (IEEE 1394 for external HDD)

- Various configuration with recording and playback conditions

- Intelligent file system for managing event triggered video data

- ATM/POS transaction information text recording and search with corresponding video

(Text search function is supported through DS412 Manager program)

- 4 pairs of sensor inputs and alarm outputs

- Built-in hardware motion detection with search function (64-division comparison)

- Back-up with IEEE 1394(FiWi).

- PTZ Control (Preset support) via RS 232 and RS 485/RS422

- User-friendly 32bit True-colored Graphic OSD Menu

- Dynamic IP (DHCP, Floating IP) support (when xDSL and Cable Modem are used)

- Wavelet compression: 1-5KB (Average file size with standard image quality)

- Embedded Linux OS for excellent stability and reliability

- IR remote controller (User controls PTZ with remote controller)

- DS412 Manager (User Interface of PC) is to be listed with 16 units of DS412 on a program

(256 chnnels (16 sets of DS412 x 16channel) are controllable through a program)

8

2. Product description

2.1. Front panel

(1) Remote

Controller Receiver

(2) Channel

Selection Button

(1) Remote Controller Receiver

(3) LED

(4) Function selection button

(2) Channel Selection Button

To select video input channel in monitoring and playback mode

(3) LED

PWR

: Displays power status. When lit, power is supplied.

(5) Direction/Replay

Button

NET

: Displays the status of Ethernet connection and rate of communication. When blinking, data being transmitted or received over the Ethernet.

REC

: Displays image recording status. The rate of blinking indicates the speed of recording.

(i.e. When blinking rapidly, DS412 is recording at a high rate; when blinking slower, the

DS412 is recording at a lower rate.)

PLAY

: Displays playback status. The rate of blinking indicates the speed of playback. (i.e. When blinking rapidly, DS412 is playing back at a high rate; when blinking slower, the DS412 is playing back at a lower rate.)

(4) Function selection button

SEQ

: To select Sequencing Mode. DS412 will automatically display all connected channels in successive order.

MULTI

SELECT

: To select the multi-channel display (4/9/16/13 divided screen).

: To select video channel for PTZ control in monitoring mode and for

ZOOM

Copy/Backup/Delete in Playback mode

: To activate the digital zoom (single channel mode only).

SEARCH/RELAY

: To search the recorded image in Playback mode or to toggle the Relay On/Off function in Monitoring mode

9

(5) Direction/Replaying Button

MENU

: To set PTZ or access Configuration menu.

ENTER

HELP

: To enter and confirm the selected menu.

: To display the image information (Date, Transfer speed, etc).

EXIT/LOCK : To exit from the selected menu or lock a screen.

Arrow key

: To Replay function in playback mode or to move a direction in other modes.

2.2. Rear panel

(1) Serial Port

& DIO

(2) Audio port

(3) Video

Output

(4) Video

Input

(5) Ethernet

(1) Serial Port & DIO

Serial

Sensor In

Relay Out

(2) Audio port

: RS232 9Pin D-Sub Connector & RS232/422/485 terminal block

: 4 sensor inputs

: 4 alarm relay outputs

- 1 audio input & 1 output

(3) Video Output

- 1 monitor output & 1 VCR output

(4) Video Input

- 4 video inputs

(5) Ethernet

(6) Power

(6) Power

10

2.3. Installation summary

- Connect Camera

- Connect Monitor

- Connect Ethernet.

(This is optional to view image on remote location or to add IP channel to DS412)

- Connect Audio

- Connect Power & Run

11

Basic configuration

3. Monitoring

Once power is supplied to DS412, default quad-multi monitoring mode (analog channels 1~4) will be displayed. The following steps apply for all DS412’s monitoring menus.

<Button control>

- Press [MULTI] button on the front panel of DS412 to change the multi screen mode (4, 9, 16, 13).

- For sequence mode, press the [SEQ] button on the front panel of DS412. To configure the sequential cycle, access the “Monitor” tab of Configuration Menu.

3.1. Viewing basic screen

- Insert AC cord’s plug in a wall outlet and turn the power switch “On.”

- LED is on and DS412 starts booting.

- After start-up, the basic screen (quad-multi) is displayed.

* If user password is set, a dialogue box for entering the password will appear.

3.2. Viewing single full screen

- Press the desired channel number button on the front panel of DS412.

- When selecting channels between channel 10 and 16, press the [+10] button first, then the second number.

- To return to the multi-view screen, press the

[MULTI] button.

3.3. Viewing multi screen

- Press the [MULTI] button to view several channels simultaneously.

- To change the multi screen configuration, press the [MULTI] button. 4, 9, 16, or 13 multi screens will be displayed.

- In quad-multi mode, images of channels 1 to 4 are displayed. Channels 1 to 9 are displayed in 9multi mode, channels 1 to 16 in 16-multi mode, and channels 1 to 13 in 13-multi mode.

12

3.4. Viewing all channels with sequence mode

- All channels can be viewed in successive order automatically using the [SEQ] button.

- Press the [MENU] button on the front panel to set-up the sequential cycle.

- Select “Monitor” tab of Configuration menu.

- Move to “Configuration” below “Monitor” using the down arrow button on DS412 front panel.

- Press the [ENTER] button to enter the menu.

- Select “Seq. Switching (sec)” and press the [ENTER] button.

- Set any value between 1 and 60 seconds.

- Then press the [SEQ] button from any viewer mode (except 16/13-multi screen).

<Note>

Sequence mode can run only when connected and activated cameras are more than multi screen.

With single full screen mode, activated cameras should be two or more. With quad-multi screen mode, there should be five or more activated cameras. With 9-multi screen mode, there should be ten or more activated cameras. (SEQUENCE MODE ONLY SUPPORTS 4- AND 9- MULTI SCREENS). Channel order cannot be changed. For example, with quad-multi screen, Ch. 1/2/3/4 are displayed and then

Ch.5/6/7/8 are displayed.

- To end sequence function, press the [SEQ] button.

13

3.5. Viewing an alarm triggered channel

- When an alarm is triggered, the related channel will pop-up full screen automatically.

- Set ‘Alarm Pop-up Screen’ function to “On” in “Configuration” under the “Monitor” tab, and set the display duration in “Pop-up Hold (sec)”

- If more than one channel is triggered by an alarm, the related channels will be displayed simultaneously in a multi-screen. In order to move current screen, press any button.

3.6. Viewing images with digital zoom

- In Single Full Screen mode, live and recorded images can be expanded using the Digital Zoom feature.

- To enable the digital zoom, press the [ZOOM] button.

- Digital Zoom will expand the image to twice its normal size.

- Default location of the digital zoom is in the center of screen. The zoom box can be moved each

10 th

step to left and right and 4 th

step up and down.

- To move the zoom box, use the [Arrow] button.

- To cancel the zoom box, press the [ZOOM] button once more.

3.7. Viewing with connected PTZ

- Pan/Tilt/Zoom (PTZ) devices can be controlled through the DS412 when a PTZ device is connected and properly configured under “Serial

Setup.

- While in Monitor mode, press the [SELECT] button.

- Channel selection icon will be displayed.

- Move the icon to the channel to control with the [Arrow] button.

- Press the [MENU] button.

- PTZ menu (Pan/Tilt, Zoom/Focus, Load Preset, Save Preset) will appear.

- Press the [ENTER] button after selecting the desired function.

14

Pan/Tilt Control

To control Pan and Tilt during live image monitoring mode.

- Press the [SELECT] button. Move the “Select” icon to the desired channel.

- Press the [MENU] button.

- Select ‘Pan/Tilt’ from the PTZ Menu.

- Control pan and tilt function using the up, down, left and right arrows.

Zoom/Focus Control

To control Zoom and Focus during live image monitoring mode.

- Press the [SELECT] button. Move the “Select” icon to the desired channel.

- Press the [MENU] button.

- Select ‘Zoom/Focus’ from the PTZ Menu.

- Control zoom and focus functions using the up, down, left and right arrows of front panel.

Load Preset

To load preset for dome camera during live monitoring mode.

- Press the [SELECT] button. Move the “Select” icon to the desired channel.

- Press the [MENU] button.

- Select ‘Load Preset’ from the PTZ Menu.

- Press number button for desired preset on the front panel.

Save Preset

To set a new preset point for dome camera during live monitoring mode

- Move dome camera to the desired position using the ‘Pan/Tilt’ and ‘Zoom/Focus’ menus.

- Press the [SELECT] button.

- Press the [MENU] button.

- Select ‘Save Preset’ from the PTZ Menu.

- Designate a number for the preset position by pressing a number button on the front panel.

15

3.8. Using relay

- To set relay on/off. (DS412 supports four relay outputs.)

- Press the [SEARCH/RELAY] button.

- The icon of “Relay On” shows.

- Press the relay number button between 1 and 4, and then the related relay out signal will be transmitted.

- In order to set relay off, press the [SEARCH/RELAY] button again.

- Then “Relay On” shows because relay keeps being set as on.

- Press the [SEARCH/RELAY] button again, and then the icon of “Relay Off” will show.

- Press the relay a number button to set off.

3.9. Using screen lock

- To set screen lock.

- For this function, user password should be set at first.

- If pressing the [EXIT/LOCK] button for 2~3 seconds, lock mode will run with showing “Screen

Locked” message.

- If lock mode runs, any function button will not be operated.

- In order to cancel lock mode, user password should be entered.

4. Playback

To replay recorded images in full screen or quad multi screen modes.

4.1. Playback via various mode

4.1.1. Playback via basic screen (full screen)

- Press the Play [►] button during monitoring mode.

- Play [►] button will begin playback initial value at 1X speed.

<Note>

When pressing the play button in multi-monitoring mode, channel 1 is always the channel displayed.

More specifically, images recorded on Channel 1 during the last 30 seconds are always displayed.

However pressing the playback button in single-channel monitoring mode, will display the selected channel. To display another channel, press the corresponding number button on the front of DS412.

16

4.1.2. Playback via multi screen

- Press the [MULTI] button during basic (single-channel) playback mode.

- Channels 1 to 4 will be displayed in the quad-multi screen.

- To display a single channel, press the corresponding number button on the front of the DS412.

4.1.3. Playback with digital zoom

- Press the [ZOOM] button during the basic (single-channel) playback mode.

- Digital Zoom will expand the image to twice its normal size.

- Default location of the digital zoom is in the center of screen. The zoom box can be moved each

10 th

step to left and right and 4 th

step up and down.

- To move the zoom box, use the [Arrow] button.

- To cancel the zoom box, press the [ZOOM] button once more.

4.1.4. Various playback modes

- ► (PLAY) : To begin playback mode and replay at 1x speed. After pressing PAUSE (▌▌), PLAY will advance recorded images frame by frame.

- ■ (STOP) : To stop replaying

- ▌▌ (PAUSE) : To pause replaying

- ►►(FAST FORWARD) : Each press of the button will increase playback speed gradually (x1, x2, x4, x8, x16)

- ◄◄ (FAST REWIND) : Each press of the button will increase playback speed gradually (x1, x2, x4, x8, x16)

- STEP FORWARD : Pressing [►, PLAY] or [►►, FAST FORWARD] button from PAUSE status, will replay image frame by frame. In order to go back to normal playback mode, press [■,

STOP] button then press [►, PLAY] or [►►, FAST FORWARD] button.

- STEP REWIND : Pressing [◄◄, FAST REWIND] button from PAUSE status, will replay image frame by frame. In order to go back to normal playback mode, press [■, STOP] button then press

[►, PLAY] or [►►, FAST FORWARD] button.

17

4.2. Using search mode

Search Mode is used to search and play specific data directly during playback mode. Data can be searched by specific Time and Date or by the Event Log browser.

From: First saving time

To: Last saving time

Select From/to and then Press [Enter] button

Button control

- Press the [SEARCH] button during playback mode.

- Search for data by entering Date/Time or by selecting an event from the Event Log browser.

- Press the [ENTER] button after entering the desired Date/Time or selecting Event from log.

- The selected images will begin to playback.

- To exit from search mode, press the [EXIT] button.

<Note> Using Log Browser

1. To move to the previous/next page, press the "Left" or "Right" buttons.

2. To move to previous log entry, press the "Up" button.

3. To move to next log entry, press the "Down" button.

18

4.3. Copy / Backup / Delete data manager

To copy/backup/delete the recorded data. This menu is activated during playback mode.

- Press the [SELECT] button and [MENU] button in Playback mode.

4.3.1. Copy image

To copy a specific data with USB memory stick.

Time

To designate copy range between 1sec and 1 hour.

Select Disk

Select copy disk.

19

4.3.2. Backup manager

Start Date & Time / End Date & Time

To designate backup range.

Select Disk

To select which storage will be used as backup device. To change the disk status, use the “Disk Manager” menu under the “System” tab.

<Note>

Backup Manager does not support USB devices. Backup Manager will ONLY work with devices connected through IEEE1394 / FireWire ports .

CD-R Media have to use above 700MB, Copy file Extension is re4, Backup file Extension is vfs3

20

4.3.3. Delete data

To delete a specific file range from the current recording HDD. This menu does not affect backup disk.

The beginning of the range is always the beginning of the recording on the HDD.

<Note>

One block size of eDVR File system is 64MB, so if you delete data , it couldn’t be delete exact time, because data delete is operate by block.

21

5. Configuration

5.1. Quick setup

There are three menus for recording setup; Quick setup, Recording, Alarm recording menu in

Configuration Menu. Quick setup is the easiest set-up, activating all four analog cameras to record with the same settings and conditions. Recording is the standard recording settings and can be customized based on time and channel. Alarm recording is the recording schedule based on alarm conditions (Motion

Detection, Sensors, etc.) Also, Quick Setup has time setting menu.

5.1.1. Date/Time

When DS412 is manufactured in factory, time zone will be set as “GMT + 9:00”.

Set the time to local time zone.

Changing DS412 time may cause time conflict with recorded images. In this case, it is strongly recommended to re-format the hard drives after making changes.

Button control

- Press [MENU] button on DS412 front panel.

- Move to “Quick Setup” menu (First tab on the Configuration menu).

- Move to “Date/Time” below “Quick Setup” using downward arrow button on DS412 front panel.

- Press the [ENTER] button on DS412 front panel.

- Set time. (The following picture will be displayed when setting time menu)

- In order to access each menu, press [ENTER] button after selecting it with upward/downward arrow button on DS412 front panel.

22

Time Zone

Set the time zone using the left/right arrow button on DS412 front panel. Every time you press left/right arrow button, time zone will change. Select the desired time zone. (To move to the previous menu, press

[EXIT] button on DS412 front panel.)

Daylight Saving

The Daylight Savings option is linked to Time Zone. Daylight Savings is only activated for time zones that use Daylight Savings. For example, selecting GMT – 7:00 Arizona will disable the option for

Daylight Savings because Daylight Savings is not used in Arizona. This menu is linked with “Time Zone” menu. Namely, if selecting daylight saving area in time zone, this menu will be activated. Oppositely if selected time zone is not enforced, it will not be. It is based on MS Windows. So this menu is for setting whether you apply ON/OFF (with left/right arrow button on DS412 front panel) in daylight saving area.

Sync with NTP

Setting up Sync with NTP(Network Time Protocol).

<Note>

Please refer to the Configuration of “NTP Settings”.

23

Time Format

Set the time format between “MM/DD/YYYY” and “YYYY/MM/DD” using the left/right arrow button on DS412 front panel.

Date/Time

Set date and time. To move from Month to Day to Year/Hour to Minute, use the left/right arrow buttons.

To select each month, each day, etc, use the up/down arrow buttons.

Apply Date/Time

Press this button to confirm the above settings. An window will pop-up warning of the possibility of time conflict with recorded images. It is strongly recommended to format the HDD after making changes to the time menu.

<Note>

Most setting values are applied automatically, when exiting from the related menu page. But “Date” &

“Time” settings are not applied automatically because they may critically affect the file system of the recorded HDD. To apply Date/Time settings confirm settings with [Apply Date/Time] button.

24

5.1.2. Recording

Its recording values are applied to all 4 channels for all time periods.

Button control

- Press [MENU] button and select to “Recording “ from the “Quick Setup” tab.

Configuration Status

Displays the recording setup status. If recording is configured with the Quick Setup, “Macro Setup” will be displayed. If recording is configured with the “Normal” and “Alarm” recording, “Custom Setup” will be displayed.

<Note>

1. When IP channel is 'Off' and all 4 analog cameras' recording conditions are set identically, the status is marked as 'Macro Setup'. Otherwise, it is marked as 'Custom Setup'.

2. When IP channel is 'On' and all 16 cameras' recording conditions are set identically, the status is marked as 'Macro Setup'. Otherwise, it is marked as 'Custom Setup'.

25

Channel Status

When “On,” all four analog channels will record based on the Quick Setup settings.

Recording Speed/Quality

There are four conditions (Low/Standard/High/Custom).

All conditions except “Custom” will synchronize “Speed (ips)” and “Quality” automatically; “Low” setting is 1ips/Q5; “Standard” setting is 5ips/Q5; “High” setting is 15ips/Q5. When using the “Custom” setting, Speed (ips) and Quality can be set separately.

Audio Recording

Enables the audio recording feature. If audio is set as “On,” and “Audio Synch with” is set as “All” (in the “Audio” menu under the “System” tab) audio will be available in Playback Mode with all channels.

Apply

Confirms the Quick Setup Recording settings. DS412 will begin recording after pressing the “Apply” button and exiting from the recording menu.

26

5.2. Camera – analog camera channels (Ch 1 ~ Ch 4)

This menu is for configuring individual cameras. In Quick Setup, camera status is automatically set as

“On.” Settings such as Brightness and Contrast can be set for each channel. The values assigned will apply for both monitoring and playback modes.

Button control

- Press [MENU] button and use the [ARROW] keys to move to each channel below the “Camera” tab.

Name

Assign a customized name to the channel.

Press [ENTER] to open the necessary dialogue box.

27

<TIP>

When assigning a name to a channel, the following dialogue box will appear. This box is also used later in the system, but the method is always the same.

- To select a letter, use the [ARROW] (◄◄ and ►► ) buttons or the number buttons on DS412 front panel; “0” to ”9". When using the [ARROW] buttons, use the [PLAY] (►) button to select each choice.

- The intersection between the horizontal and the vertical bar is the selected choice.

- Press the ► button to confirm the selected value.

- Or enter the related numbers in order of horizontal/vertical. (For example, in order to select “C”, press [3] and [2] button.)

- After setting all values, press the [Exit] button.

- Function Key

9 : Enter

: Back Space & delete

: Space

: Previous Code Page

: Next Code Page

28

Status

Set “On/Off” using the ◄◄ or ►► buttons after pressing the [ENTER] button.

Type

Displays the video-input signal. NTSC is the signal used in North America. To toggle the setting, use dip switch on the rear panel of DS412.

For each of the following settings, use the [ENTER] button to access the setting, then the [ARROW] buttons to change the values.

Color

Set “Color/ B/W” using the ◄◄ or ►► buttons.

Gain/Brightness/Contrast

Set the value between –9 and +9 using the ◄◄ or ►► buttons.

Covert

It is possible to Monitoring On/Off.

If you set On, you can’t see monitoring channel.

PTZ Home

If you do not operate while PTZ Idle Time, It will move to preset #1 position

PTZ Idle Time

Set PTZ Operating Time, If you set 20 Sec after 20sec it will go to preset #1 position.

PTZ Port

Set the value using the ◄◄ or ►► buttons.

Address

Press the [ENTER] button to open the dialogue box.

29

5.3. Recording – analog camera channels (Ch 1 ~ Ch 4)

Recording - This menu is for configuring the recording settings based on channel and timetable. If this menu is configured Quick Setup, the previous Quick Setup values will be replaced by the Recording settings.

5.3.1. Global setting

Almost similar with Quick Setup, it will be setting up all of analogue channel same condition every hour.

<Note>

1. There is no audio recording configuration, you could be setting up Special Time Recording and Event

Recording

2. You must click “Apply” button for confirm.

3. Please refer to the Each Channel setting

30

5.3.2. Each channel setting

Time Schedule

Each camera can be set to record based on four time schedules; Weekday (Day) / Weekday (Night) /

Weekend (Day) / Weekend (Night). Each schedule can be configured under the “System” tab.

31

< Setting Time Schedule >

In order to set time schedule, move to “System” menu.

Weekday Start/End

Press [ENTER] to access the Time Setting. Set the range for “Weekday” between Monday and Sunday using the ◄◄ or ►► buttons. “Weekend” is set automatically based on “Weekday” range.

Day Start/End

Set the range for “Day” using the up/down buttons. The “Night” range is set automatically based on

“Day” range.

Recording Speed/Quality

There are five conditions; No Rec./Low/Standard/High/Custom.

All conditions except “Custom” synchronize “Speed (ips)” and “Quality” automatically; “Low” setting is

1ips/Q5; “Standard” setting is 5ips/Q5; “High” setting is 15ips/Q5. When using the “Custom” setting,

Speed(ips) and Quality can be set separately.

Maximum recording speed is restrict as like a below table.

2 Channel

4 channel

30 ips

15 ips

32

Clearer Image Mode

This menu is to recording highest image quality, if you setting up On mode, you could be recording clearer image without ghost. But recording size will be increasing 2 to 20 (comparative to recording).

Also defends on the recording condition frame rate will be decreasing

Special Time Recording

This menu is to designate different recording conditions during “Special Times.” “Special Time” is designated under the “System” tab.

There are five conditions; No Rec/ Low/Standard/High/Same as above.

33

< Setting Special Time >

To set ”Special Time,” move to “System” tab.

Up to four zones can be designated as “Special Time.”

Event Recording

Press the [ENTER] button to access the Event Recording feature. Set “On/Off” using the ◄◄ or ►► buttons.

Event recording condition is set under the “Alarm Recording” tab.

This setting is used to configure the DS412 to record data according to an alarm condition, such as

Motion Detection (MD), sensors, etc.

34

5.4. Setting alarm recording.

This menu is to configure for the settings for alarm recording conditions. To activate this schedule, set

“Event Recording” under the “Recording” tab to “On.”

Also, before alarm recording, you must set “Alarm Source”

5.4.1. Setting sensor

This menu is setting up sensor input type.

Sensor will be support two type Normal Open (N.O.) and Normal Close(N.C.).

Global

You could be setting up all sensors in same condition, you have to choose Off/N.O/N.C and the click

“Apply:” button.

Configuration

You could be setup 4 each sensor. (S1 ~ S2)

35

5.4.2. Setting motion detection

This menu is setting up MD for each channel. Global is setting up all channel of same condition (Cam

#1~Cam#16), also you could be setup each channel separately.

Motion Detection

Choose from among four sensitivity conditions; Off, Low, Standard, High., Highest.

MD Area

Set up of MD area. There consist of 64 blocks (8 X 8).

If you click “Set All”, you could be setup all of screen. Also Select “Clear All” to remove blocks from detecting motion.

Include Video Loss

The DS412 will only work with NO (Normal Open) sensors. If sensors are connected, turn each sensor

“On.”

<Note>

If you setting up Global, you must be click “Apply” Button.

36

5.4.2.1. Setting motion detection per each channel

Setting up of each channel MD is same as Global setting, if you setting up each channel MD, you could b e setting up MD block additionally.

Custom Area

User could be set up of MD area. It consists of 64 blocks (8 X 8).

Default value is “Select All”. Select “Custom Area”, MD area will be open.

37

<Setting MD

Area

>

Designate a specific area for motion detection triggered event.

Press the “Custom Area” button, to customize the motion detection area. The area is divided into 64 blocks (8 X 8).

Selected MD area is indicated in dark gray. To remove blocks from motion detection, select the block using the [ARROW] buttons and press the [ENTER] button. Press the [EXIT] button when finished.

38

5.4.3. Setting text

In order to display or record text with image, it should be set OSD menu of COM1 part as

“SystemÆSerial setup”.

Recording

In order to make DS412 input text data, both of menus should be set as “On/off”.

Sync Text With

To set channel to synchronize with text

Seek Header

If a protocol is built in DS412 like Star Finger 007, this setting is needless. Otherwise, DS412 can’t recognize which parameter value is input to DS412. Namely, all information has starting point and ending point. Header means starting point that is always inserted. So when this header data is transmitted to

DS412, DS412 can recognize it as starting point. Two headers can be set maximally.

Delimiter

Because delimiter value may be different, refer to the manual of related device.

39

Timeout(ms)

The following “Lines” means maximal text line that can be included within a data. However length of each data may be different. Because DS412 can’t recognize it automatically, timeout menu is needed.

Namely, if specific time passes after DS412 receives the last line, DS412 will regard it as normal data and decide to record.

Lines

To set maximal line of a data

40

5.4.4. Setting global alarm recording

It was setting up same condition of all analog channels.

Sensor/MD

To set Sensor/MD alarm to synchronize.

Pairing means 1: 1 synchronize with Channel and Sensor/MD

Text

In case of setting "On" and input text, it was processed by Alarm Event and then saved

Clearer Image(Bigger File Size)

In Alarm Recording, you can set Clearer Image as On/Off.

<Note>

1. If you setting up Global, you must be click “Apply” Button.

2. Detail information, please refer to the each channel setting up

41

5.4.5. Setting each channel

Alarm Source (*=All)

It is possible to text input 4 Sensor/MD throughout Alarm Source (IPCam : 16)

Sensor/MD selection is set under the “Number button”

Text selection is using arrow key and then select On/Off

In according to Alarm input, designate to PTZ Preset

<Note>

1. * : Press the “ENTER” button.

2. – or # : Press the number “0” button.

Recording Speed/Quality

There is four setting condition. (Low/Standard/High/Custom).

All conditions except “Custom” synchronize “Speed (ips)” and “Quality” automatically; “Low” setting is

1ips/Q5; “Standard” setting is 5ips/Q5; “High” setting is 15ips/Q5. When using the “Custom” setting,

Speed (ips) and Quality can be set separately.

Pre Alarm (sec)

Setting up maximum 10 sec

Post Alarm (sec)

Setting up maximum 60 sec

42

5.5. Alarm action.

This menu is to set the relay commands according to each time schedule. You could be set up five time zone Full Time, Weekday(Day), Weekday(Night), Weekend(Day), Weekend(Night). After Set up schedule, you have to set up relay, Buzzer, E-mail etc

5.5.1. Schedule

Select Action Source

Alarm triggered events (MD or Sensors) can be set to trigger Relays 1 through 4 or Any(Relay1 ~ Relay4,

Buzzer ,E-mail etc.), also It is possible to Text On/Off.

<Note>

1. ANY : Press the “ENTER” button.

Special Time

Enable “Special Time” to apply the relay schedule to the Special Time Zone.

<Note>

1. Global setting is setting up time schedule in same condition

2. If you setting up Global, you must be click “Apply” Button.

43

5.5.2. Setup

Relay Configuration

Set up its use of R1 ~ R4

Buzzer

Set up the condition of using Buzzer or not.

E-mail Addr.

Input E-mail address to receive alarm message.

Sender Addr.

Filing up E-mail sender’s item, E-mail form will be who@where

Mail Duration (min)

E-mail Duration does not send a message every time, there is setting up time. And then periodically send a message. (Possible to set up 1min to 30 min)

<Note>

If you using E-mail Duration, you have to set up DNS

IPCam Relay Configuration

You could be set up R5 ~ R16 of IPCam Relay.

44

5.6. Monitor

Alarm Pop-up/Pop-up Hold(sec)

To set alarm pop-up screen. Pop-up duration time can be set between 5 and 10 seconds. If setting as

“Keep”, pop-up screen keeps holding. In order to cancel Keep mode, press another channel button.

Seq. Switching(sec)

To set sequence time between 1 and 60 seconds.

Auto-Flicker OSD

You could be On/Off Anti-Flicker form this menu.

Turn on the Anti-Flicker : Screen will be smooth and Flicker will be disappearing.

Turn off the Anti-Flicker : Screen will be sharp and Flicker will be appear.

Depends on the your monitor property, choose On/Off.

<Note>

After channel#1 is pop-up, if channel #2 is pop-up before pop-up hold time goes, it is divided into four

Screen and display channel #1 and #2.

Then from final pop-up time on hold time is automatically extended.(To maximum 8 channels)

45

User Sequence Configuration

You could be edit auto conversion function by Users Mode.

<Caution>

1. Users Mode can be defined upto Maximum 16.

2. Above picture defined 6 sequence, 4 partition(1,2,3,4) Æ Full Screen(1) Æ 4 partition(5,6,7,8) Æ

Full screen(5) Æ Full screen(8) Æ 9 partition(9,10,11,12,13,14,15,16)

46

5.7. System

5.7.1. Audio

DS412 supports one channel audio input. This single audio channel can be replayed with any connected channel or with all of them.

Recording

Set to “On” using the [ENTER] button and the [ARROW] buttons to record audio.

Audio Gain

Increases or decreases the sensitivity to the audio signal. Can be set between –7 and +8.

+20dB

To amplify the audio input signal. Should ONLY be used when using an external microphone.

Sync Audio with

Designate which channel(s) to synchronize audio with during playback.

47

5.7.2. Time schedule

To designate Weekday/Weekend and Day/Night.

Weekday Start/End

Press [ENTER] to access the Time Setting. Set the range for “Weekday” between Monday and Sunday using the ◄◄ or ►► buttons. “Weekend” is set automatically based on “Weekday” range.

Day Start/End

Set the range for “Day” using the up/down buttons. The “Night” range is set automatically based on

“Day” range.

.

48

5.7.3. Special time

You could be set up specific time (for example lunch time, meeting time etc.)

Up to four zones can be designated as “Special Time.”

49

5.7.4. Security

User Password

Designate a User’s Password for access to monitoring and playback. Default password is “0000”.

Admin Password

Designate an Administrator’s Password to control access to Configuration Menu and full system control authority. Default password is “9999”

Remote Setup

When set to “Enable,” users can configure DS412 through the S/W interface from a remote site via network.

Remote Relay

Enables access to the “Relay” menu from a remote site.

50

5.7.5. Disk setup

Auto Deletion

Images and data recorded under the “Normal” condition are automatically deleted as the hard-drive(s) reaches capacity. Images are written over based on a first-in first-out basis.

Backup Reminder

A Backup Reminder can be set to remind users to backup the HDD. The reminder can be set to appear daily, weekly, or monthly.

Day/Date/Time

To set the time for the Backup Reminder.

51

5.7.6. Network

There are four sub-menus; Network, xDSL, WRS, and Port Setting.

5.7.6.1. Network

This page is to define network type and set network addresses forDS412.

Type

This is to select proper network interface (Ethernet/xDSL) with which DS412 is connected. If DS412 is connected with Internet dedicated line, cable modem line or on LAN environment, select network interface as ‘Ethernet.’

If DS412 is connected on xDSL line that needs PPPoE process to connect to the Internet, administrator should select ‘xDSL.’ However, if the xDSL line does not need PPPoE process, administrator should select ‘Ethernet,’ even though DS412 is connected on xDSL line.

DHCP

Basically, this menu is for the lines that have Ethernet interfaces such as Internet dedicated line, cable modem line and LAN. If administrator activates ‘DHCP’ menu, all addresses are set automatically by

DS412 detecting them from DHCP server of your ISP. The detected addresses are not displayed on the screen. The addresses do not need to be entered manually unless ‘DHCP’ is disabled.

52

DHCP can also be used for xDSL (PPPoE) interface. Sometimes, all computers on a Local Area Network

(LAN) share a single Floating / Dynamic IP address. In this case, the DS412 should be assigned a private

IP address and have DHCP enabled. Users on the LAN can connect to the DS412 using the private IP address and outside users can connect to the DS412 over the Internet.

IP Address, NetMask, and Gateway Address, DNS, Port

Administrator may configure IP address, Network Mask, Broadcast address, Gateway, DNS addresses and Port of DS412.

53

5.7.6.2. xDSL

If DS412 is connected on xDSL line and needs PPPoE process, the network administrator should configure the user ID and password for PPPoE. ID.

User ID/Password

When DS412 is connected to xDSL, access ID and Password should be entered.

Status

Displays the DS412 connection status.

54

5.7.6.3. WRS

When a DS412 is installed under the environment of Cable Modem or xDSL Modem connection, its IP address changes whenever it reconnects to the Internet Service Provider (the DS412 has a Dynamic or

Floating IP address). In this case users who don’t know the changed IP address cannot get access to the

DS412. DS412 with dynamic IP should be registered to the WEBGATE Registration Server (WRS) server in order to make it easy for users to find the changed IP address, when they want to access the

DS412.

To register dynamic IP address to WRS, configure the descriptions below. If using xDSL modem or Cable modem, configuration should be the same.

WRS Interval

WRS Interval should be set at 3600 seconds. This designates the frequency the DS412 will update information to the WRS. If the interval is set lower than 3600 seconds, WEBGATE cannot guarantee connectivity. If the WRS received too many updates, it may close the connection to the unit. The WRS maintains registered units on the server list for two days. If no signal is received before two days, the

WRS will delete the unit from the register.

WRS URL

This is to configure a server address for registration. WRS address of WEBGATE Inc. is

“www.webgateinc.com”.

55

Group ID

Group ID is for discriminating and managing the information received by the WRS from the DS412 belonging to group. The group ID should be unique to avoid unauthorized access to the DS412.

Unauthorized users will not be able to access the DS412 unless they have a login name and password, but they will be able to see the unit on their registration list.

Internet

Group ID and IP

Grup ID and IP

DS412 IP

Assi gn G rou p ID

ISP

Group ID

DS412s of selected Group

WRS

DS412 registers its

Group ID and

Dynamic IP address on WRS

Status

Displays the registration status of the DS412.

eDVR Manager

eDVR Manager accesses WRS and gets

DS412's IP addresses of registered Group

Register WRS address and

Group ID on eDVR Manager

Administrator /

User

56

NPT is synchronized all of machine in network.

Sync With NTP

. On/Off NTP function

NTP Mode

Set up the NTP mode.(client or Both)

NTP Server Loc.

If you set up Client, NTP mode will be Enable. (Set up the NTP server to connect Local Network or

Internet)

NTP Local Server IP

At the time of a setup by Local , it will be set to enable NTP Server Loc

You have to input eDVR’s IP or NTP server’s IP from Local Network.

Interval (min)

To set periodic time.

<Note>

When client is NTP Mode, you must be set up Sync with NTP “On”

57

5.7.7. Serial setup

There are two RS232 menus (One for external devices connected via the DB-9 pin, and the other for PTZ setting) and one RS 422/485 menu.

Device

Designate the connected external device.

Interface

Used to designate the protocol on the RS422/RS485 Menu.

Baud rate/Parity/Stop (bit)/Data (bit)

Each value should be set according to the specifications of the connected external device.

58

5.7.8. Miscellaneous

Button control

- Press [MENU] button and select “Miscellaneous” below the “System” tab.

Remote Control ID

Up to sixteen DS412s can be controlled with a single IR Remote Control. Designate each unit with a unique number under the ‘Remote Control ID’ menu.

< How to register

remote controller >

- Aim remote controller at the DS412.

- Press the “ID” button of remote controller until DS412 reacts.

- If remote controller’s ID agrees with DS412’s, all the LEDs on the front panel of the DS412 will light up and a buzzer will sound.

- OSD menus can now be set with the remote controller.

59

Keyboard Control Addr

To set keyboard’s control address in order to operate all DS412’s menus with keyboard. Default value is

“1”.

Keyboard PTZ Addr

To set keyboard’s PTZ address in order to operate each PTZ camera with keyboard. If setting just first camera’s address of each DS412, another cameras’ are designated automatically. For example, 1 st

DS412 has five cameras and 2 nd

DS412 has six cameras, keyboard PTA address of 1 st

DS412 should be set as “1” and one of 2 nd

DS412 be set as “6”. Be cautious that PTZ addressed are assigned to all cameras automatically in spite of non PTZ camera.

* Since Keyboard Control Addr and Keyboard PTZ Addr run differently according to the kind of

Keyboard, it is recommended to refer to each tech note for using keyboard.

DVR ID

For use with the DVR Manager to control and manage several DS412s.

IP Cam Menu

To enable the IP camera options for the “Camera,” “Recording,” and “Alarm Recording,” tabs.

Language

To select the language used for the OSD Menu.

Reset Values

To reset current configured values. To reset DVR, press the “Reset Values” button.

60

5.8. Utility

The following description is how to add/format internal or external HDD. DS412 supports various external storages.

Button control

- Press [MENU] button and move to “Utility” below the “System” tab.

61

5.8.1. Disk manager

A connected HDD is detected automatically.

Select Disk

To select a Disk.

Action

Select from “Add/Format/Confirm Removed/Add used”.

[Add]

[Remove]

: To add disk (you must be use empty disk in partition table.

: To remove current HDD formatted for use.

[Confirm

Removed]

[Add used]

Fat32 Format

: Removed HDDs are still listed in the system and can be re-added (“Add

Used”) without losing data. “Confirm Removed” will permanently remove the drive and all data will be lost.

: It is to add a HDD that has been previously used. The disk does not need to be re-formatted.

<File system compatibility> Disk used at ver 1.x and 2.x of eDVR can be reused without deleting its data.

When connected external device, you have to use Fat32 Format.

62

Format the partition of below 250GB to copy/backup by FAT32 file system.

It is necessary to create partition by using Disk manager on PC for this work.

In case the size is over 250GB, format each partiton by FAT32 file system after creating multiple partitons smaller than 250GB.

Type

There are several symbols to indicate HDD status.

[R]

: Available for recording

[V]

: Connected and formatted as DS412’s file system.

If using ‘Add used’ command, it will be changed to [R]. There is no need to format again.

[F]

: Connected but not available file system. After using ‘Add’, need to format to make HDD available for recording [R].

[X]

: HDD cable is not connected or HDD has a problem. It is recommended to delete from list using ‘Confirm Removed’.

[C]

: Available for backup to the external CD-Writer.

< File system compatibility >

Instructions

- When upgrading DVR is completed, HDD used at below version will have the sign of [V] at Disk

Manager.

- Select HDD at Select Disk.

- Select ‘Add Used’ at Action and press the button of ‘Apply’.

- Click OK at ‘NOTICE - Disk reused for recording’.

- Converting process will be going on after the message of ‘Converting files from old version may take a few minutes’ appears.

- If the sign of Type changes into [R], the status of HDD is usable.

Warning

- HDD used at below version will have sign of [V] when upgrade is completed and re-use is possible only with Add Used.

- ‘Add Used’ process may take from 10 seconds to a few minutes according to the capacity of HDD.

- Playback recorded data of HDD used at below version may have problem and CD backup is impossible.

- The function such as Watermark or Smart Search can not be supported at recorded data of below version.

- Please note that some functions and backup can not be supported as above explanation even if file system is basically designed to be conpatible between each other, so data backup is recommended before upgrading.

63

5.8.2. USB utility

It is possible to firmware upgrade, set up, saving, text file saving for printing throughout USB device

Update F/W

It is possible to update firmware by USB device. After connect USB device and then Press the “Update

F/W” button. File extension is “~date”

Print Settings(.txt)

It is possible to print by USB Text file. First you have to open saved file by editor and then print it.

<TEXT saving set up file Item>

- Camera setting information

- Recording setting information

- Alarm Recording setting information

- Network setting information

- Audio setting information

Load Settings

64

Saved setting value saves to USB device

Save Settings

Currently setting value saves to USB device

65

Advanced configuration

DS412 has the default settings of IP camera channels disabled. DS412 can support 12 IP channels and 4 analog cameras simultaneously. And current system can be expandable easily with connecting text or keyboard device.

6. Using IP cam

6.1. Activating IP cam menu

To setup the IP cam menu, first enable the IPCam Menu under the “System” tab.

Button control

- Move to “Miscellaneous” below “System” tab.

- Set “IP Cam Menu” to “Enable.” This will activate the IP cam menus for the Configuration Menu.

66

6.2. Camera setting – IP camera channels (Ch 5 ~ Ch 16)

Setting up the IP Cameras is similar to setting up the analog channels. However there are specific menus only for IP cam; for example, the ‘Configuration’ menu and ‘Network’ menu in the IP cam setting menu.

6.2.1. Configuration

Button control

- Press [MENU] button and move to each “IPCam #5 to #16“ below “Camera” menu. Then select

“Configuration” menu by pressing the [ENTER] button and using the ◄◄ or ►► buttons.

Name

Press the [ENTER] button to open the related dialogue box and change the camera name.

Status

Press the [ENTER] button and use the ◄◄ or ►► buttons to set the camera to “On” or “Off.” Unlike the analog channels, the IP cam’s default value is “Off.” After registering the IP camera, set the status to

“On.”

67

User ID/Password

The related IP camera’s ID/Password should be entered. Default value is “guest/guest.” To change the

ID/Password, press [ENTER] to open the dialogue box (similar to the “Name” box.)

Type

Set “WESP/WebEye/I-Rec” by pressing the [ENTER] button and using the ◄◄ or ►► buttons.

CH

Designate the channel for the IP camera. For example, the WebEye B106 has 6 possible channels, the I-

Rec B104 has 4 possible channels, etc.

IP Address(URL)

Press the [ENTER] button to open related dialogue box to manually enter an IP address. To register an IP cam, there are two methods; manually enter the IP using the dialog box (similar to the box for “Name”) or select an IP from the Local IP Cam List. To use the Local IP Cam List, please refer to the next page.

Port

Press the [ENTER] button to open the related dialogue box to manually enter the Port Address. The default values are different according to IP camera type; “8080” is the “WebEye” default and “8001” is the “i-Rec” default.

Band Width Limit(KB/s)

To control transfer speed with data size. Basically DS412 can also control it with ips control. It can be set between 10KB and 100KB against the overload of network bandwidth. When setting 1ips at network camera menu and 10KB at this menu, DS412 receives video data of 1ips within 10KB. If data size is 9KB, it will not be problem. But if it is 11KB, one image will not be able to be transmitted per second.

68

6.2.2. Local IP cam list

This menu is for easy registering of local IP cameras. If DS412 is connected to network and IP cameras are connected to the same local network, they are listed in this menu.

Search

Select this button and press the [ENTER] button to refresh the list of local IP cameras.

Select Cam

Select “Select Cam” by pressing the [ENTER] button and select the desired IP camera from the list. When using this method, the IP Address, Type, and Port are automatically configured on the previous screen.

69

6.3. Recording – IP camera channels (Ch 5 ~ Ch 16)

These settings are same as with the analog channels.

70

6.4. Alarm rec. - IP cam channel (Ch 5 ~ Ch 16)

These settings are same as with the analog channels.

71

6.5. IPCam sensor

When using IPCam, you can use sensor like a DVR’s sensor. You could be add 12 sensor so totally you can use 16 sensor.

IPCam # Sensor #

S5 5 1

S6 5

S7 #

2

3

S8 # 4

When setting up as mentioned above, IPCam‘s sensor 5,sensor 1, it is used like DVR’s Sensor 5.

This function only possible I-Rec or WESP

6.6. IPCam Relay

When using IPCam, you can use relay like a DVR’s relay. Possible to add 12 IP Camera so totally upto 16

IPCams.

IPCam Relay Configuration

Set up IPCam Relay R5 to R16. It is only support IPCam Type.

72

7. Connecting external device

7.1. Using text device

In order to use text device, the following four menus should be set; Text menu, Serial Setup’s RS232 menu, Alarm Rec. menu, Rec. menu

7.1.1. Setting at text menu

Set both Recording and Monitoring as “On”

Set “Sync. Text with” value.

If the connected device is Star Finger 007, select it at “Device” menu. If not, set ”Manual” and each submenus.

73

7.1.2. Setting at serial setup’s RS232 menu

Set RS232’s device menu as “Text”. And set baud rate, parity, stop, and data.

74

7.1.3. Setting at alarm rec. menu

If you want use text as a alarm source, set text event as “On”.

75

7.1.4. Setting at recording menu

Set event recording as “On” at each time schedule.

<Note>

Whenever pressing the “Help” button, information of displayed image is different.

The default value of Monitoring mode is to show just channel number. Then next step is to show channel name and text, event status, and HDD status.

The default value of Playback mode is to show all information. The next level is to show channel name and text, event status, and channel number.

So in order to view text data, press the “Help” button once at both Monitoring and Playback modes.

76

7.2. Using keyboard

In order to use keyboard, the following two menus should be set; Serial Setup’s RS232 menu, Serial

Setup’s PTZ menu

7.2.1. Setting at serial setup’s RS232 menu

Set RS232’s device menu as “Keyboard”. And set baud rate, parity, stop, and data.

7.2.2. Setting at serial setup’s PTZ menu

Set PTZ camera to control with keyboard. For more detailed technical solution, please contact the closest local WEBGATE’s distributor.

77

APPENDIX

APPENDIX

78

Appendix #1 Technical specification

Hardware

32bit RISC Embedded processor (200MIPS)

Flash memory: 8Mbyte

RAM: 32Mbyte

OS: Embedded Linux

Storage device

Image quality control

Image compression

Video channel

Recording performance

(on 360X243) analog Ch

Schedule recording

Matrix digital output schedule

Configurable recording conditions

Pre / Post alarm recording

Int.: 2 HDD bays

Ext: 3 IEEE 1394 (FireWire) connection ports

Supports Disk Management tool for all disks

(Reboot is required when HDD changed)

Total manageable capacity: 4 TB

5 Levels (Q1-Q5)

Compression algorithm: Differential Wavelet

Compression rate: 20:1 ~500:1

Average file size: 3 ~ 5KB (Standard Quality)

NTSC or PAL video format are supported

4Ch. analog video inputs via BNC connector

Max. 60fps(NTSC) / 50fps(PAL) in total

Max 30 fps (NTSC) per channel if 2ch used

Max. 15fps (NTSC) per channel if 4ch used

Daily: Day / night / Four-segment time frame

Weekly: Weekdays / Weekends

Status: Normal / Event

Daily: Day / Night / Four-segment time frame

Weekly: Weekdays / Weekends

Conditions: MD, sensor input

Recording speed: None to 30 fps

Image quality: 5 Levels

Event conditions: MD & sensor inputs

Pre alarm recording: 1 ~ 10 seconds

Post alarm recording: 1 ~ 60 seconds

79

Intelligent file system

Event triggered video data storage

Event log recording

Data-loss protection against power failure

Overwrite prevention of event triggered data

Log archiving on HDD

Log search & monitoring via Network

Data(video & audio Clip) Back-up

Data Copy(Max. 1 minute’s video clip)

External HDD: IEEE1394 (FireWire) or USB

PnP memory stick: USB port

VHS video tape: Video output port for VCR

Backup notification: Daily / Weekly / Monthly

PnP USB storage(Compact flash, Smart media,

Memory stick, SD card)

Displaying performance

Digital zoom

Frame rate on CCTV Monitor: Max. 120fps

Frame rate on PC: Max. 60ips

Display channel: Quad, Auto sequential

Play speed: 1x, 2x, 4x, 8x, 16x (FDW & REV)

Supports step-forward, step-reverse.

Instant data access based on time and event log

2 times digital zoom (Live & Playback Mode)

Event triggered pop-up video

Triggered by motion detection or sensor input

Ports: RS232, RS485/RS422

PTZ control

Local user

Front panel push button & IR Remote

(controls IP video channels as well)

Remote user

Sensor inputs and alarm outputs

Audio recording and playback

On-the-screen PTZ control on PC

Preset: 8 points per channel

Group: 1 group per channel

Return Home Position’ support

Software-controlled 4 sensor inputs

Software-controlled 4 alarms outputs

Input: 1Ch, line-in, 1Vpp

Output: 1Ch, line-out, 1Vpp

Level: -7 ~ 8 Recording level control

Support 20dB Amp. for low level audio recording

Supports local and remote audio monitoring

80

Network

Simul. user support via network

Management and Firmware upgrades

Security

Power supply (included)

Power consumption(with 2HDD)

Environmental spec

Protocol: TCP/IP, ARP, ICMP, DHCP, PPPoE

Line: 10/100Mbps Ethernet (RJ-45)

Monitoring: Max. 5 users

Playback: Max. 5 users

Firmware upgrades via Network

Password (User or Administrator Authentication)

Watermarking (For image copying)

Input: AC 100~240V, 50~60 Hz

Output: DC 12V, 5A

Booting: Max. DC 12V ± 10%, 4.5A (54W)

Normal: DC 12V ± 10%, 3.9A (35W)

Operating: 41 ~ 113 degrees F.

Storage: -49 ~ 149 degrees F.

81

Appendix #2 Utilizing IP addresses on local network

#2.1 Introduction

Most of our businesses are done via Internet, lately. We play with information by transmitting through emails and searching the world of Internet. IP address is what we utilize to access to the Internet.

Currently used IP addresses are limited. And there are 5 classes’ networks in the world for now, and a network contains lots of IP addresses. A network can hold limited IP addresses. The numbers depend on network class. 5 classes are from A to E, and the most common one is C class network.

#2.2 IP construction and network class

1) IP construction

2) Network class

A class: A network that contains IP addresses from 0 to 127 at room ‘X1’.

- Network ID: X1

- Host ID: X2, X3, X4

- Total number of A-class networks is 128 in the world.

B class: A network that contains IP addresses from 127 to 191 at room ‘X1’.

- Network ID: X1, X2

- Host ID: X3, X4

- Total number of B-class networks is 65,534 in the world.

C class: A network that contains IP addresses from 192 to 223 at room ‘X1’.

- Network ID: X1, X2, X3

- Host ID: X4

- It is the most common network in the world, and the total number of C-class networks is 2,097,152

D class: A network that contains IP addresses from 224 to 239 at room ‘X1’. D-class network is for multicasting, and it is not allowed to use for common users.

E class: A network that contains IP addresses from 240 to 225 at room ‘X1’. E-class network is reserved.

82

#2.3 C-class network

1) Features of Addresses

IP address: Three digits number in room ‘X4’ are for Host ID, and the numbers are from 0 to 255.

Among the numbers, 0 is used for Network ID, 1 is used for Router IP (Gateway address) and 255 is used for Broadcast address. Therefore the numbers from 2 to 244 are IP addresses that can be assigned to

WebEye, i-Rec B104, PC etc.

Network ID: It is to identify a network. Generally the first number is assigned as Network ID.

Gateway address: It is an IP address of router that is connecting Internet and local network. Remote users can access local network over Internet through the gateway (router). Generally the second number is assigned as Gateway address.

Broadcast address: It is to broadcast to all devices that are connected on local network. Broadcast address is a destination for broadcasting and it is determined by calculating. All devices connected on local network have a same Broadcast address.

Subnet Mask: It is to divide a local network into two remote networks. Subnet mask shows the IP quantity in a certain network. The numbers that can be used as subnet mask are limited (0, 4, 8, 16, 32, 64,

128)

2) Network configuration

(1) To use as one network

Network ID: xxx.xxx.xxx.0

Gateway Address: xxx.xxx.xxx.1

Subnet Mask: 255.255.255.0

Broadcast Address: xxx.xxx.xxx.255

IP Addresses: xxx.xxx.xxx.2 – xxx.xxx.xxx.254

83

(2) To use as two sub-networks (1/2 + 1/2)

Sub-Network ID: xxx.xxx.xxx.0

Gateway Address: xxx.xxx.xxx.1

Subnet Mask: 255.255.255.128

Broadcast Address: xxx.xxx.xxx.127

IP Addresses: xxx.xxx.xxx.2 – xxx.xxx.xxx.126

Sub-Network ID: xxx.xxx.xxx.128

Gateway Address: xxx.xxx.xxx.129

Subnet Mask: 255.255.255.128

Broadcast Address: xxx.xxx.xxx.255

IP Addresses: xxx.xxx.xxx.130 – xxx.xxx.xxx.254

(3) To use as three sub-networks (1/4 + 1/4 + 1/2)

Sub-Network ID: xxx.xxx.xxx.0

Gateway Address: xxx.xxx.xxx.1

Subnet Mask: 255.255.255.192

Broadcast Address: xxx.xxx.xxx.63

IP Addresses: xxx.xxx.xxx.2 – xxx.xxx.xxx.62

Sub-Network ID: xxx.xxx.xxx.64

Gateway Address: xxx.xxx.xxx.65

Subnet Mask: 255.255.255.192

Broadcast Address: xxx.xxx.xxx.127

IP Addresses: xxx.xxx.xxx.66 – xxx.xxx.xxx.126

Sub-Network ID: xxx.xxx.xxx.128

Gateway Address: xxx.xxx.xxx.129

Subnet Mask: 255.255.255.128

Broadcast Address: xxx.xxx.xxx.255

IP Addresses: xxx.xxx.xxx.130 – xxx.xxx.xxx.254

84

(4) To use as four sub-networks (1/4 + 1/4 + 1/4 + 1/4)

Sub-Network ID: xxx.xxx.xxx.0

Gateway Address: xxx.xxx.xxx.1

Subnet Mask: 255.255.255.192

Broadcast Address: xxx.xxx.xxx.63

IP Addresses: xxx.xxx.xxx.2 – xxx.xxx.xxx.62

Sub-Network ID: xxx.xxx.xxx.64

Gateway Address: xxx.xxx.xxx.65

Subnet Mask: 255.255.255.192

Broadcast Address: xxx.xxx.xxx.127

IP Addresses: xxx.xxx.xxx.66 – xxx.xxx.xxx.126

Sub-Network ID: xxx.xxx.xxx.128

Gateway Address: xxx.xxx.xxx.129

Subnet Mask: 255.255.255.192

Broadcast Address: xxx.xxx.xxx.191

IP Addresses: xxx.xxx.xxx.130 – xxx.xxx.xxx.190

Sub-Network ID: xxx.xxx.xxx.192

Gateway Address: xxx.xxx.xxx.193

Subnet Mask: 255.255.255.192

Broadcast Address: xxx.xxx.xxx.255

IP Addresses: xxx.xxx.xxx.194 – xxx.xxx.xxx.254

85

WEBGATE Inc.

6F, Hanlim Venture Town Bldg., 689-6, Geumjeong-dong, Gunpo-si,

Gyeonggi-do, Korea (435-862)

Tel : (82-31) 428-9300

Fax : (82-31) 428-3955

[email protected]

www.webgateinc.com

WEBGATE Inc. USA

465 Halstead St. Suite 110, Pasadena, California 91107, USA

Tel : (626) 351-6500

Fax : (626) 351-3660

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project